Uniflo 1x00 registers version 27

Register Register name Unit Byte Data type Password Min Max Description In setup Event Live/
Number address level value value chksum log Set
0 Za - 00B0 REAL32 4 bytes (single) Read only Actual supercompressibilitifactor No Live
1 Slave address - 0001 UINT8 1 byte (byte) 3 ModBus address for the unit No Set
2 Time - 0002 TIME 6 bytes 1 Unit time in the format No Live
(yymmddhhnnss) YYMMDDHHmmSS
3 Zb - 00B4 REAL32 4 bytes (single) 2 Base supercompressibilitifactor Yes Set
4 Temperature correction - 1B0C Datablock 112 bytes 3 Temperature correction table for Yes Set
table calculation temperature, based on
the HW offset and Temperature
sensor correction data
5 Battery remaining Days 00F6 UINT16 2 bytes (integer) 1 Number of days left before battery No Live
has to be changed. When the value
is 0 the alarm “Low battery warning”
6 Interval log power average MJ 0200 REAL32 4 bytes (single) Read only Average power calculated for the No Live
last interval log period / also used
as register for temporary power
average calculations
7 Interval log temperature °C 0204 REAL32 4 bytes (single) Read only Average temperature calculated for No Live
average the last interval log period / also
used as register for temporary
temperature average calculations
8 Interval log pressure BarA 0208 REAL32 4 bytes (single) Read only Average pressure calculated for the No Live
average last interval log period / also used
as register for temporary pressure
average calculations
9 Interval log corrected flow m3/h 020C REAL32 4 bytes (single) Read only Average corrected flow calculated No Live
average for the last interval log period / also
used as register for temporary
corrected flow average calculations
10 Interval log converted flow Nm3/h 0210 REAL32 4 bytes (single) Read only Average converted flow calculated No Live
average for the last interval log period / also
used as register for temporary
converted flow average calculations
11 Daily log power average MJ 0214 REAL32 4 bytes (single) Read only Average power calculated for the No Live
last daily log period / also used as
register for temporary power
average calculations
Created Date: 2. April 2007 Rev. Date: 2. April 2007 Case no. TAE 1155
Init: TWF Topic group: Uniflo 1x00 Page 1 of 23
/conversion/tmp/scratch/437499433.doc
Uniflo 1x00 registers version 27

Register Register name Unit Byte Data type Password Min Max Description In setup Event Live/
Number address level value value chksum log Set
12 Daily log temperature °C 0218 REAL32 4 bytes (single) Read only Average temperature calculated for No Live
average the last daily log period / also used
as register for temporary
temperature average calculations
13 Daily log pressure average BarA 021C REAL32 4 bytes (single) Read only Average pressure calculated for the No Live
last daily log period / also used as
register for temporary pressure
average calculations
14 Daily log corrected flow m3/h 0220 REAL32 4 bytes (single) Read only Average corrected flow calculated No Live
average for the last daily log period / also
used as register for temporary
corrected flow average calculations
15 Daily log converted flow Nm3/h 0224 REAL32 4 bytes (single) Read only Average converted flow calculated No Live
average for the last daily log period / also
used as register for temporary
converted flow average calculations
16 Configuration checksum - 01F0 UINT16 2 bytes (integer) Read only The configuration checksum is a No Live
CRC checksum on the configuration
values of the Uniflo. The
configuration checksum is
automatically calculated/updated
after a call to the function “Update
EEPROM” (reg. 205). The
configuration checksum is used by
the Uniflo to continually monitor the
configuration values for faults (The
configuration values is scanned
every day shift). If a configuration
fault is detected, the alarm no. 26
“Configuration error” is set
17 Log line checksum - 0152 UINT16 2 bytes (integer) Read only Log line checksum is used for No Live
calculation of CRC checksum on
each log line. The log line checksum
has to be added into the log setup
to be stored with each log line. Log
line checksum can be used in all log
types.
Created Date: 2. April 2007 Rev. Date: 2. April 2007 Case no. TAE 1155
Init: TWF Topic group: Uniflo 1x00 Page 2 of 23
/conversion/tmp/scratch/437499433.doc
Uniflo 1x00 registers version 27

Register Register name Unit Byte Data type Password Min Max Description In setup Event Live/
Number address level value value chksum log Set
18 Pulse out register 1 Location 00C4 UINT8 1 byte (byte) 1 Register no. of the register to use No Set
pointer for Pulse output 1
19 Pulse out register 2 Location 00C5 UINT8 1 byte (byte) 1 Register no. of the register to use No Set
pointer for Pulse output 2

20 Pulse out diversion factor 1 Option 00C6 UINT8 1 byte (byte) 1 Pulse diversion factor for pulse No Set
output 1. Valid values is described
in “Pulse out diversion factor X
description” table
21 Pulse out diversion factor 2 Option 00C7 UINT8 1 byte (byte) 1 Pulse diversion factor for pulse No Set
output 2. Valid values is described
in “Pulse out No diversion factor X
description” table
22 Numbers of powerups - 000F UINT8 1 byte (byte) 3 Number of times the unit have No Live
powered up
23 Pressure AD-count - 0010 UINT16 2 bytes (integer) Read only The AD count of the last pressure No Live
measurement
24 Temperature AD-count - 0012 UINT16 2 bytes (integer) Read only The AD count of the last No Live
temperature measurement
25 Pressure sensor - 00DA UINT16 2 bytes (integer) Read only The AD count of the last pressure No Live
temperature AD-Count sensor temperature measurement
26 Pulse output period cycle Option 00F4 UINT8 1 byte (byte) 1 Minimum length of each output No Set
time pulse (ON/OFF). Valid values is
found in the “Pulse output period
cycle time description” table
27 Heat value MJ/Nm3, 0064 REAL32 4 bytes (single) 2 Conversion factor for calculation Yes Chg Set
KWh/Nm3 Energy from the Base volume
28 Display setup table - 1CC8 Datablock 18 bytes 2 Table with 18 registers to be Yes Set
displayed in the custom display. The
value 0 is equal to no value to be
displayed
29 Operator ID - 00F0 4 byte Char 0 Used to identify by whom changes No Set
in the configuration are made. The
ID is stored in the event log for each
change.

Created Date: 2. April 2007 Rev. Date: 2. April 2007 Case no. TAE 1155
Init: TWF Topic group: Uniflo 1x00 Page 3 of 23
/conversion/tmp/scratch/437499433.doc
Uniflo 1x00 registers version 27

Register Register name Unit Byte Data type Password Min Max Description In setup Event Live/
Number address level value value chksum log Set
30 Event log - CCE8 Datablock 4000 bytes Read only The Event log stores metrological No Live
changes in the unit with Operator
ID,
The Event log stores 200 records.
31 Actual security level - 00D6 UINT8 1 byte (byte) Read only 0 3 Shows the actual security level. The No Live
level is set according to the
Password send to the unit and the
current settings of the two DIP
switches on the top print. The Actual
security level is set to zero 240 sec
after the password is sent
32 Volume control m3 00B8 INTREAL 8 bytes 3 0 99999999 Volume accumulated for LF B input No Chg
and multiplied with the pulse value. Live
The register includes both an 32 bit
Integer part and a 32 bit fraction
part
33 System data - 1BC4 STR22 22 bytes 3 Internal used Yes Set
34 Pulse check every Pulses 0124 UINT16 2 bytes (integer) 1 0 65535 Number of pulses on LF A or LF B Yes Set
input before evaluation of “Max
pulse error” is done and a “Pulse
count error” alarm is raised if the
difference between LF A and LF B
input exceeds “Max pulse error”
pulses
35 Alarm log - 11A0 Datablock 1000 bytes Read only 100 alarm logs with date/time, alarm No Live
type and state
36 Pressure BarA 0080 REAL32 4 byte (single) Read Only Pressure from last measurement No Live
37 Temperature °C 0084 REAL32 4 byte (single) Read Only Temperature from last measurementNo Live
38 Conversion factor - 0088 REAL32 4 byte (single) Read Only Conversion factor from last No Live
measurement
39 Pulse value m3/pulse 00F8 REAL32 4 byte (single) 3 0 99999999 Pulse value for LF A and LF B input Yes Chg Set
40 Flow corrected m3/h 0078 REAL32 4 byte (single) Read Only Corrected flow. When only LF is No Live
used for pulse input, corrected flow
= measured flow
41 Flow converted Nm3/h 007C REAL32 4 byte (single) Read Only Converted flow No Live
42 Volume corrected m3 0068 INTREAL 8 bytes 3 0 99999999 The accumulated corrected volume. No Chg Live
Created Date: 2. April 2007 Rev. Date: 2. April 2007 Case no. TAE 1155
Init: TWF Topic group: Uniflo 1x00 Page 4 of 23
/conversion/tmp/scratch/437499433.doc
Uniflo 1x00 registers version 27

Register Register name Unit Byte Data type Password Min Max Description In setup Event Live/
Number address level value value chksum log Set
The register includes both an 32 bit
Integer part and a 32 bit fraction
part
43 Volume converted m3 0070 INTREAL 8 bytes 3 0 99999999 The accumulated converted volume. No Chg Live
The register includes both an 32 bit
Integer part and a 32 bit fraction
part
44 Volume corrected Integer m3 0068 UINT32 4 byte (long) Read Only Integer value of the accumulated No Chg Live
part corrected volume
45 Volume corrected decimal m3 006C REAL32 4 byte (single) Read Only Decimal value of the accumulated No Chg Live
part corrected volume
46 Volume converted Integer Nm3 0070 UINT32 4 byte (long) Read Only Integer value of the accumulated No Chg Live
part converted volume
47 Volume converted decimal Nm3 0074 REAL32 4 byte (single) Read Only Decimal value of the accumulated No Chg Live
part converted volume
48 Alarm setup table - 1A18 Datablock 192 bytes Read Only Table with setup values for the 96 Yes Set
alarms
49 Flowstop after Sec 0126 UINT16 2 bytes (integer) 1 10 600 Time before flow is set to 0 when no Yes Set
pulses is received
50 Pressure low limit BarA 00FC REAL32 4 byte (single) 1 0.6 80 Pressure low limit, when the Yes Set
pressure is below this limit the alarm
11 “Pressure low limit” is set. The
alarm is cleared when the pressure
is above the limit again
51 Pressure high limit BarA 0100 REAL32 4 byte (single) 1 0.6 80 Pressure high limit, when the Yes Set
pressure is above this limit the
alarm 12 “Pressure high limit” is set.
The alarm is cleared when the
pressure is below the limit again
52 Temperature low limit °C 0104 REAL32 4 byte (single) 1 -40 70 Temperature low limit, when the Yes Set
temperature is below this limit the
alarm 9 “Temperature low limit” is
set. The alarm is cleared when the
temperature is above the limit again
53 Temperature high limit °C 0108 REAL32 4 byte (single) 1 -40 70 Temperature high limit, when the Yes Set
temperature is above this limit the

Created Date: 2. April 2007 Rev. Date: 2. April 2007 Case no. TAE 1155
Init: TWF Topic group: Uniflo 1x00 Page 5 of 23
/conversion/tmp/scratch/437499433.doc
Uniflo 1x00 registers version 27

Register Register name Unit Byte Data type Password Min Max Description In setup Event Live/
Number address level value value chksum log Set
alarm 10 “Temperature high limit” is
set. The alarm is cleared when the
temperature is below the limit again
54 Flow corrected high limit m3/h 010C REAL32 4 byte (single) 1 0 99999999 Flow corrected high limit, when the Yes Set
corrected flow is above this limit the
alarm 13 “Flow high limit” is set. The
alarm is cleared when the corrected
flow is below the limit again
55 Flow converted high limit Nm3/h 0110 REAL32 4 byte (single) 1 0 99999999 Flow converted high limit, when the Yes Set
converted flow is above this limit the
alarm 14 “Flow conv. high limit” is
set. The alarm is cleared when the
converted flow is below the limit
again
56 Power high limit MJ/h or 0114 REAL32 4 byte (single) 1 0 99999999 Power high limit, when the power is Yes Set
kW above this limit the alarm 15
“Energy high limit” is set. The alarm
is cleared when the power is below
the limit again
57 Fallback pressure BarA 0118 REAL32 4 byte (single) 3 0.6 80 The fallback pressure is used as the Yes Chg Set
actual pressure when a pressure
error occurs.
The alarms that activates the
fallback pressure are: Alarm 3
“Pressure sensor error”, Alarm 6
“Pressure sensor EPROM error”,
Alarm 16 “Pressure sensor temp
error”, Alarm 20 “AD error” and
Alarm 21 “Pressure range error”
58 Fallback temperature °C 011C REAL32 4 byte (single) 3 -40 70 The fallback temperature is used as Yes Chg Set
the actual temperature when a
temperature error occurs.
The alarms that activates the
fallback temperature are: Alarm 4
“Temperature sensor error” and
Alarm 20 “AD error”
59 Turn off display after Sec 00C1 UINT8 1 byte (byte) 3 0-4 240-241 Turn off display after sets the time Yes Set
Created Date: 2. April 2007 Rev. Date: 2. April 2007 Case no. TAE 1155
Init: TWF Topic group: Uniflo 1x00 Page 6 of 23
/conversion/tmp/scratch/437499433.doc
Uniflo 1x00 registers version 27

Register Register name Unit Byte Data type Password Min Max Description In setup Event Live/
Number address level value value chksum log Set
from the last push button activation
until the graphical display powers
off. If the value is set to 0 the
display will never turn on and if the
value is set to 241 the graphical
display will never turn off.
60 Base pressure BarA 0128 REAL32 4 byte (single) 3 0.6 80 Base pressure is used in the Yes Chg Set
conversion calculation and also for
calculation of the base
supercompressibilitifactor
61 Base temperature °C 012C REAL32 4 byte (single) 3 -40 70 Base temperature is used in the Yes Chg Set
conversion calculation and also for
calculation of the base
supercompressibilitifactor by the
configuration tool
62 Max pressure Bar A 00DC REAL32 4 byte (single) 3 0.6 80 Max pressure is used by the Yes Chg Set
configuration tool as the highest
pressure in the Gas table
supercompressibilitifactor matrix
63 Min pressure Bar A 00E0 REAL32 4 byte (single) 3 0.6 80 Min pressure is used by the Yes Chg Set
configuration tool as the lowest
pressure in the Gas table
supercompressibilitifactor matrix
64 Max temperature °C 00E4 REAL32 4 byte (single) 3 -40 70 Max temperature is used by the Yes Chg Set
configuration tool as the highest
temperature in the Gas table
supercompressibilitifactor matrix
65 Min temperature °C 0130 REAL32 4 byte (single) 3 40 70 Min temperature is used by the Yes Chg Set
configuration tool as the lowest
temperature in the Gas table
supercompressibilitifactor matrix
66 Alarm status table - 0234 Datablock 12 bytes Read only The 96 bits in the Alarm status No Live
tables shows the actual status of the
96 alarms in the unit.
If the bit value is 0 the alarm is OFF
and if the value is 1 the alarm is ON
67 Alarm count table - 1BE4 Datablock 96 bytes 3 0 255 The 96 bytes in the Alarm count No Live
Created Date: 2. April 2007 Rev. Date: 2. April 2007 Case no. TAE 1155
Init: TWF Topic group: Uniflo 1x00 Page 7 of 23
/conversion/tmp/scratch/437499433.doc
Uniflo 1x00 registers version 27

Register Register name Unit Byte Data type Password Min Max Description In setup Event Live/
Number address level value value chksum log Set
table shows how many times each
alarm has been active
68 Power MJ/h or 008C REAL32 4 byte (single) Read Only Power is the actual energy flow No Live
kW calculated by multiplying the
converted flow with the heat value
69 Set alarm reg. - 00D9 UINT8 1 byte (byte) 0 0 1 Set alarm reg. Sets or clears the No Set
Alarm 22 “Extern alarm”. The value
0 clears the alarm and the value 1
sets the alarm
70 Pressure Manufacture and - 1E02 STR22 22 bytes (string) Read only The manufacture and type of the No Live
type pressure sensor read from the
EEPROM in the pressure sensor
71 Pressure sensor style - 1E1F STR1 1 byte (char) Read only The pressure sensor style read from No Live
the EEPROM in the pressure
sensor. The value can be A for
absolute sensor or R for relative
sensor (not implemented)
72 Pressure sensor range Bar 1E20 REAL32O 4 byte (single, Read only The max pressure for the pressure No Live
reverse data storing) sensor read from the EEPROM in
the pressure sensor
73 Pressure serial number - 1E24 UINT32O 4 byte (long, Read only The serial number of the pressure No Live
reverse data storing) sensor, read in the EEPROM in the
pressure sensor
74 Pressure day of calibration Day 1E28 UINT8 1 byte (byte) Read only 1 31 The day of calibration of the No Live
pressure sensor, read in the
EEPROM in the pressure sensor
75 Pressure month of Month 1E29 UINT8 1 byte (byte) Read only 1 12 The month of calibration of the No Live
calibration pressure sensor, read in the
EEPROM in the pressure sensor
76 Pressure day of calibration Year 1E2A UINT8 1 byte (byte) Read only 00 99 The year (only the last two digits) of No Live
calibration of the pressure sensor,
read in the EEPROM in the
pressure sensor
77 Pressure signal at 1 bar mV 1E2B REAL32O 4 byte (single, Read only The pressure signal at 1 bar and No Live
reverse data storing) 20°C, read in the EEPROM in the
pressure sensor

Created Date: 2. April 2007 Rev. Date: 2. April 2007 Case no. TAE 1155
Init: TWF Topic group: Uniflo 1x00 Page 8 of 23
/conversion/tmp/scratch/437499433.doc
Uniflo 1x00 registers version 27

Register Register name Unit Byte Data type Password Min Max Description In setup Event Live/
Number address level value value chksum log Set
78 Pressure signal at FS mV 1E2F REAL32O 4 byte (single, Read only The pressure signal at Full Scale No Live
reverse data storing) and 20°C, read in the EEPROM in
the pressure sensor
79 Pressure temperature mV 1E33 REAL32O 4 byte (single, Read only The temperature signal at 20°C, No Live
signal reverse data storing) read in the EEPROM in the
pressure sensor
80 Reset Alarm - 1E04 UINT16 2 bytes (integer) 1 0 0 Command for reset of all alarms. All No Set
alarms are set to OFF state
81 Clear Alarm - 1E06 UINT16 2 bytes (integer) 1 0 0 Command for reset of all alarms No Set
and sets alarm counts to 0. All
alarms are set to OFF state
82 AD amplify Option 00EA UINT8 1 byte (byte) 1 0 1 ADC amplifying of the pressure Yes Chg Set
sensor signals. See AD-Amplify
description table for valid options
83 Clear configuration log - 1E0A UINT16 2 bytes (integer) 3 Command for clearing the No Set
configuration log
84 Lock gas table - 1E0C UINT16 2 byte (integer) 2 Command for locking the gas table No Set
before updating it. The unit uses the
old supercompressibilitifactor when
the gas table is locked
85 Unlock gas table - 1E0E UINT16 2 Command for unlocking the gas No Set
table after updating it. The unit can
hereafter calculate the new
supercompressibilitifactor from the
new gas table. The data written is
the new checksum of the gastable.
If the checksum isn’t equal to the
checksum of the transferred gas
table the alarm no. 29 “Conversion
table transfer error” is set and the
gas table isn’t unlocked.
86 Update correction table - 1E10 UINT16 2 Command for loading correction No Set
table from EEPROM to RAM to be
used as current table
87 Update Gas Data - 1E12 UINT16 2 Not used No Set
88 Make Snapshot - 1E14 UINT16 2 bytes (integer) 1 Command for making a snapshot No Set

Created Date: 2. April 2007 Rev. Date: 2. April 2007 Case no. TAE 1155
Init: TWF Topic group: Uniflo 1x00 Page 9 of 23
/conversion/tmp/scratch/437499433.doc
Uniflo 1x00 registers version 27

Register Register name Unit Byte Data type Password Min Max Description In setup Event Live/
Number address level value value chksum log Set
log
89 Pulse out 1 enable Option 00C8 UINT8 1 byte (byte) 1 0 1 Enable pulse output 1. Valid values No Set
can be read in the Pulse out X
enable description table
90 Pulse out 2 enable Option 00C9 UINT8 1 byte (byte) 1 0 1 Enable pulse output 2. Valid values No Set
can be read in the Pulse out X
enable description table
91 Menu File - 1B98 STR22 22 bytes (string) 3 Name of the graphical menu. Also Yes Set
used as the name of the file
containing the menu for the
configuration tool
92 Interval log EEPROM - 00D7 UINT8 1 byte (byte) Read only 1 4 Number of EEPROM's for the No Live
Interval log. Automatically detected
on initial power on.
93 Graphic display gain - 00CA UINT8 1 byte (byte) 3 Brightness control for the graphical No Set
display
94 Graphic display contrast - 00CB UINT8 1 byte (byte) 3 Contrast control for the graphical No Set
display
95 Energy MJ or 0090 INTREAL 8 bytes 3 0 99999999 Energy accumulated equal to No Chg Live
kWh volume converted multiplied with the
Heat value. The register includes
both an 32 bit Integer part and a 32
bit fraction part
96 Energy integer part MJ or 0090 UINT32 4 byte (long) 3 0 99999999 Integer part of Energy No Chg Live
kWh
97 Energy decimal part MJ or 0094 REAL32 4 byte (single) 3 0 0,9999999 Decimal part of Energy No Chg Live
kWh
98 Option Card changed - 00D8 UINT8 1 byte (byte) 1 Is used by the configuration No Allways Set
program to indicate changed of
option board setup. The Uniflo used
changed of this register to log
changed of option board in the
event log
99 Temperature sensor source Option 00E8 UINT8 1 byte (byte) 3 Setting of temperature source for Yes Set
the unit. The valid type can be found
in the Temperature sensor source

Created Date: 2. April 2007 Rev. Date: 2. April 2007 Case no. TAE 1155
Init: TWF Topic group: Uniflo 1x00 Page 10 of 23
/conversion/tmp/scratch/437499433.doc
Uniflo 1x00 registers version 27

Register Register name Unit Byte Data type Password Min Max Description In setup Event Live/
Number address level value value chksum log Set
description table
100 Pressure sensor source Option 00E9 UINT8 1 byte (byte) 3 Setting of pressure source for the Yes Set
unit. The valid type can be found in
the Pressure sensor source
description table
101 Alarm active 1-32 Data 0234 UINT32 4 byte (1 Read only Live alarms no. 1 to 32 No Live
bit/alarm)
102 Alarm active 33-64 Data 0238 UINT32 4 byte (1 Read only Live alarms no. 33 to 64 No Live
bit/alarm)
103 Alarm active 64-96 Data 023C UINT32 4 byte (1 Read only Live alarms no. 64 to 96 No Live
bit/alarm)
104 Alarm reg. 1-32 Data 1BD8 UINT32 4 byte (1 Read only Registered alarms no. 1 to 32 No Live
bit/alarm)
105 Alarm reg. 33-64 Data 1BDC UINT32 4 byte (1 Read only Registered alarms no. 33 to 64 No Live
bit/alarm)
106 Alarm reg. 64-96 Data 1BE0 UINT32 4 byte (1 Read only Registered alarms no. 64 to 96 No Live
bit/alarm)
107 I/O table Data 00CC Datablock 10 byte (byte) Read only Option board table. Byte 1-7 is No Live
holding type and subtype of
mounted option board.
108 Volume measured m3 0098 INTREAL 8 bytes 3 0 99999999 The accumulated measured No Chg Live
volume. The register includes both
an 32 bit Integer part and a 32 bit
fraction part
109 Pressure sensor check Data 1E8A UINT8 (byte) Read only Checksum read from the pressure No Live
sum sensor
110 Interval log register Data FFE0 Datablock 20 byte (byte) 3 Setup table for interval log. Each Yes Set
byte represents a column in the log
and is set to register number. Only
register under 256 can be used.
111 24 hour log register Data 4000 Datablock 20 byte (byte) 1 Setup table for 24-hour log. Each Yes Set
byte represents a column in the log
and is set to register number. Only
register under 256 can be used.
112 Snap shot log register Data 6000 Datablock 20 byte (byte) 1 Setup table for snap shot log. Each Yes Set
byte represent a column in the log
Created Date: 2. April 2007 Rev. Date: 2. April 2007 Case no. TAE 1155
Init: TWF Topic group: Uniflo 1x00 Page 11 of 23
/conversion/tmp/scratch/437499433.doc
Uniflo 1x00 registers version 27

Register Register name Unit Byte Data type Password Min Max Description In setup Event Live/
Number address level value value chksum log Set
and is set to register number. Only
register under 256 can be used.
113 Alarm triggered log register Data 2000 Datablock 20 byte (byte) 1 Setup table for Alarm triggered log Yes Set
register. Each byte represents a
column in the log and is set to
register number. Only register under
256 can be used.
114 SW Version and type Text 1DC6 STR22 22 byte (string) Read Only Uniflo identification of version and No Set
type
115 Installation number Text 1588 STR22 22 byte (string) 1 Information register for storing No Set
installation number
116 Meter number Text 159E STR22 22 byte (string) 1 Information register for storing No Set
meter information
117 Meter size Text 15B4 STR22 22 byte (string) 1 Information register for storing No Set
meter size information
118 Customer Text 15CA STR22 22 byte (string) 1 Information register for storing No Set
customer data
119 Date of installation Text 15E0 STR22 22 byte (string) 1 Information register for storing date No Set
of installation
120 Meter index Text 15F6 STR22 22 byte (string) 1 Information register for storing No Set
meter index data
121 Project no. Text 160C STR22 22 byte (string) 1 Information register for storing No Set
project number
122 Serial number Text 1622 STR22 22 byte (string) 1 Unique serial number for the Uniflo Yes Set
123 Flow sensor Text 1638 STR22 22 byte (string) 1 Information register for storing flow No Set
sensor manufacture and type
124 Temperature sensor Text 164E STR22 22 byte (string) 1 Information register for storing No Set
temperature sensor manufacture
and type
125 Interval log size - FFF4 UINT16 (integer) 3 Size of the interval log (number of Yes Set
logs)
126 24 hour log size - 4014 UINT16 (integer) 1 Size of the 24 hour log (number of Yes Set
logs)
127 Snap shot log size - 6014 UINT16 (integer) 1 Size of the snap shot log (number of Yes Set
logs)
128 Alarm triggered log size - 2014 UINT16 (integer) 1 Size of the alarm triggered log Yes Set
Created Date: 2. April 2007 Rev. Date: 2. April 2007 Case no. TAE 1155
Init: TWF Topic group: Uniflo 1x00 Page 12 of 23
/conversion/tmp/scratch/437499433.doc
Uniflo 1x00 registers version 27

Register Register name Unit Byte Data type Password Min Max Description In setup Event Live/
Number address level value value chksum log Set
(number of logs)
129 Interval log width - FFF6 UINT8 (byte) 3 Width of the interval log (number of Yes Set
columns)
130 24 hour log width - 4016 UINT8 (byte) 1 Width of the 24 hour log (number of Yes Set
columns)
131 Snap shot log width - 6016 UINT8 (byte) 1 Width of the snap shot log (number Yes Set
of columns)
132 Alarm triggered log width - 2016 UINT8 (byte) 1 Width of the alarm triggered log Yes Set
(number of columns)
133 Flow measured m3/h 00A0 REAL32 4 byte (single) Read Only Measured flow. When only LF is Yes Live
used for pulse input, corrected flow
= measured flow
134 Methane Mol % 1668 REAL32 4 byte (single) 2 Gas component Information used to Yes Chg Set
calculate correction table
135 Nitrogen Mol % 166C REAL32 4 byte (single) 2 Gas component Information used to Yes Chg Set
calculate correction table
136 CO2 Mol % 1670 REAL32 4 byte (single) 2 Gas component Information used to Yes Chg Set
calculate correction table
137 Ethane Mol % 1674 REAL32 4 byte (single) 2 Gas component Information used to Yes Chg Set
calculate correction table
138 Propane Mol % 1678 REAL32 4 byte (single) 2 Gas component Information used to Yes Chg Set
calculate correction table
139 Water Mol % 167C REAL32 4 byte (single) 2 Gas component Information used to Yes Chg Set
calculate correction table
140 Hydrg. Sul. Mol % 1680 REAL32 4 byte (single) 2 Gas component Information used to Yes Chg Set
calculate correction table
141 Hydrogen Mol % 1684 REAL32 4 byte (single) 2 Gas component Information used to Yes Chg Set
calculate correction table
142 Carbon monoxide Mol % 1688 REAL32 4 byte (single) 2 Gas component Information used to Yes Chg Set
calculate correction table
143 Oxygen Mol % 168C REAL32 4 byte (single) 2 Gas component Information used to Yes Chg Set
calculate correction table
144 i-Butane Mol % 1690 REAL32 4 byte (single) 2 Gas component Information used to Yes Chg Set
calculate correction table
145 n-Butane Mol % 1694 REAL32 4 byte (single) 2 Gas component Information used to Yes Chg Set
calculate correction table
Created Date: 2. April 2007 Rev. Date: 2. April 2007 Case no. TAE 1155
Init: TWF Topic group: Uniflo 1x00 Page 13 of 23
/conversion/tmp/scratch/437499433.doc
Uniflo 1x00 registers version 27

Register Register name Unit Byte Data type Password Min Max Description In setup Event Live/
Number address level value value chksum log Set
146 i-Pentane Mol % 1698 REAL32 4 byte (single) 2 Gas component Information used to Yes Chg Set
calculate correction table
147 n-Pentane Mol % 169C REAL32 4 byte (single) 2 Gas component Information used to Yes Chg Set
calculate correction table
148 n-Hexane Mol % 16A0 REAL32 4 byte (single) 2 Gas component Information used to Yes Chg Set
calculate correction table
149 n-Heptane Mol % 16A4 REAL32 4 byte (single) 2 Gas component Information used to Yes Chg Set
calculate correction table
150 n-Octane Mol % 16A8 REAL32 4 byte (single) 2 Gas component Information used to Yes Chg Set
calculate correction table
151 n-Nonane Mol % 16AC REAL32 4 byte (single) 2 Gas component Information used to Yes Chg Set
calculate correction table
152 n-Decane Mol % 16B0 REAL32 4 byte (single) 2 Gas component Information used to Yes Chg Set
calculate correction table
153 Helium Mol % 16B4 REAL32 4 byte (single) 2 Gas component Information used to Yes Chg Set
calculate correction table
154 Argon Mol % 16B8 REAL32 4 byte (single) 2 Gas component Information used to Yes Chg Set
calculate correction table
155 Gas calculation formula Option 16BC UINT8 1 byte (byte) 2 Formula used for calculate Yes Chg Set
correction table. See encoding in
table below
156 Gas composition Text 16BE STR22 22 byte (string) 2 Gas composition description Yes Allways Set
157 Gas composition revision Time 16D6 TIME 6 bytes 2 Timestamp for change of Gas Yes Chg Set
time (yymmddhhnnss) composition
158 Density 16DC REAL32 4 byte (single) 2 Gas density used to calculate Yes Chg Set
correction table
159 Gas conversion table Data 16E0 Datablock 800 byte (200 2 Gas conversion table (5 pres x 10 Yes Set
single) temp)
160 Password level 3 Text 1A00 STR8 8 byte (string) 3 Password for level 3 Yes Set
161 Password level 2 Text 1A08 STR8 8 byte (string) 2 Password for level 2 Yes Set
162 Password level 1 Text 1A10 STR8 8 byte (string) 1 Password for level 1 Yes Set
163 Log reorganize bits - 00C3 UINT8 (byte) 0 Is used to reorganize logs after No Set
changed. See encoding in table Log
reorganization description below
164 Correction factor - 00A4 REAL32 4 byte (single) Read Only Correction factor used for calculate No Live
correction. When only LF is used for
Created Date: 2. April 2007 Rev. Date: 2. April 2007 Case no. TAE 1155
Init: TWF Topic group: Uniflo 1x00 Page 14 of 23
/conversion/tmp/scratch/437499433.doc
Uniflo 1x00 registers version 27

Register Register name Unit Byte Data type Password Min Max Description In setup Event Live/
Number address level value value chksum log Set
pulse input, Correction factor = 1
165 Option board SW version - 0200 Datablock 14 byte (7 Read Only SW version on each mounted option No Live
UINT16 (integer)) board. Only updated after power up.
166 Option board serial number - 020E Datablock 28 byte (7 Read Only Serial number on each mounted No Live
UINT32 (long)) option board. Only updated after
power up.
167 HF Card type - 0300 UINT16 (integer) Read Only HF card subtype No Live
168 SN Table - 0200 Datablock 40 byte (7 Read Only Option board serial numbers. ÚINT No Live
UINT32 (long)) 1-7 is holding serial numbers of
mounted option boards.
169 Temperature code Text 1B7C STR22 22 byte (string) 3 Temperature code used for Yes Chg Set
correction of temperature signal.
170 Interval log temperature °C 0020 REAL32 4 byte (single) 3 Temperature Minimum for interval No Live
min. log. The value is reset after each
interval log
171 Interval temperature max. °C 0024 REAL32 4 byte (single) 3 Temperature Maximum for interval No Live
log. The value is reset after each
interval log
172 Interval log pressure min. BarA 0028 REAL32 4 byte (single) 3 Pressure Minimum for interval log. No Live
The value is reset after each interval
log
173 Interval log pressure max. BarA 002C REAL32 4 byte (single) 3 Pressure Maximum for interval log. No Live
The value is reset after each interval
log
174 Interval log Flow corrected m3/h 0030 REAL32 4 byte (single) 3 Flow corrected Minimum for interval No Live
min. log. The value is reset after each
interval log. Flow corrected is the
same as Flow measured when LF
input is used
175 Interval log Flow corrected m3/h 0034 REAL32 4 byte (single) 3 Flow corrected Maximum for interval No Live
max. log. The value is reset after each
interval log. Flow corrected is the
same as Flow measured when LF
input is used
176 Interval log Flow converted Nm3/h 0038 REAL32 4 byte (single) 3 Flow converted Minimum for interval No Live
min. log. The value is reset after each
Created Date: 2. April 2007 Rev. Date: 2. April 2007 Case no. TAE 1155
Init: TWF Topic group: Uniflo 1x00 Page 15 of 23
/conversion/tmp/scratch/437499433.doc
Uniflo 1x00 registers version 27

Register Register name Unit Byte Data type Password Min Max Description In setup Event Live/
Number address level value value chksum log Set
interval log
177 Interval log Flow converted Nm3/h 003C REAL32 4 byte (single) 3 Flow converted Maximum for No Live
max. interval log. The value is reset after
each interval log
178 Daily log temperature min. °C 0040 REAL32 4 byte (single) 3 Temperature Minimum for daily log. No Live
The value is reset after each daily
log
179 Daily log temperature max. °C 0044 REAL32 4 byte (single) 3 Temperature Maximum for daily log. No Live
The value is reset after each daily
log
180 Daily log pressure min. BarA 0048 REAL32 4 byte (single) 3 Pressure Minimum for daily log. The No Live
value is reset after each daily log
181 Daily log pressure max. BarA 004C REAL32 4 byte (single) 3 Pressure Maximum for daily log. No Live
The value is reset after each daily
log
182 Daily log Flow corrected m3/h 0050 REAL32 4 byte (single) 3 Flow corrected Minimum for daily No Live
min. log. The value is reset after each
daily log. Flow corrected is the
same as Flow measured when LF
input is used
183 Daily log Flow corrected m3/h 0054 REAL32 4 byte (single) 3 Flow corrected Maximum for daily No Live
max. log. The value is reset after each
daily log. Flow corrected is the
same as Flow measured when LF
input is used
184 Daily log Flow converted Nm3/h 0058 REAL32 4 byte (single) 3 Flow converted Minimum for daily No Live
min. log. The value is reset after each
daily log
185 Daily log Flow converted Nm3/h 005C REAL32 4 byte (single) 3 Flow converted Maximum for daily No Live
max. log. The value is reset after each
daily log
186 Interval log Power min. MJ/h or 0018 REAL32 4 byte (single) 3 Energy flow = Power Minimum for No Live
kW interval log. The value is reset after
each interval log
187 Interval log Power max. MJ/h or 001C REAL32 4 byte (single) 3 Energy flow = Power Maximum for No Live
kW interval log. The value is reset after

Created Date: 2. April 2007 Rev. Date: 2. April 2007 Case no. TAE 1155
Init: TWF Topic group: Uniflo 1x00 Page 16 of 23
/conversion/tmp/scratch/437499433.doc
Uniflo 1x00 registers version 27

Register Register name Unit Byte Data type Password Min Max Description In setup Event Live/
Number address level value value chksum log Set
each interval log
188 Daily log Power min. MJ/h or 0060 REAL32 4 byte (single) 3 Energy flow = Power Minimum for No Live
kW daily log. The value is reset after
each daily log
189 Daily log Power max. MJ/h or 0014 REAL32 4 byte (single) 3 Energy flow = Power Maximum for No Live
kW daily log. The value is reset after
each daily log
190 Volume measured integer m3 0098 INTREAL 8 bytes 3 0 99999999 The accumulated integer part of No Chg Live
part measured volume.
191 Volume measured decimal m3 009C REAL32 4 byte (single) 3 0 0,9999999 The accumulated decimal part of No Chg Live
part measured volume.
192 Volume at error m3 00A8 INTREAL 8 bytes 3 0 99999999 The accumulated measured volume No Chg Live
at error. The register includes both
an 32 bit Integer part and a 32 bit
fraction part
193 Volume at error integer part m3 00A8 UINT32 4 byte (long) 3 0 99999999 The accumulated integer part of No Chg Live
measured volume at error.
194 Volume at error decimal m3 00AC REAL32 4 byte (single) 3 0 0,9999999 The accumulated decimal part of No Chg Live
part measured volume at error.
195 Superior heat value MJ/mn3 1B08 REAL32 4 byte (single) 2 Gas component Information used to Yes Chg Set
calculate correction table
196 C6+ value Mol % 1B92 REAL32 4 byte (single) 2 Gas component Information used to Yes Chg Set
calculate correction table
197 C6+ enabled Option 1B96 UINT8 (byte) 2 Enable = 1 / disable = 0 use of C6+ Yes Chg Set
value
198 AD pressure offset - 0008 UINT8 (byte) 3 0 255 Offset of pressure sensor AD-count Yes Chg Set
= Value – 128 (Default = 128 =
offset of 0)
199 AD pressure temperature - 0009 UINT8 (byte) 3 0 255 Offset of pressure temperature Yes Chg Set
offset sensor AD-count = Value – 128
(Default = 128 = offset of 0)
200 Volume at Error Option 00D4 UINT8 1 byte (byte) 3 Enable = 1 / disable = 0 Counting in Yes Chg Set
Volume measured when error
201 TZ Mode Option 00D5 UINT8 1 byte (byte) 3 Enable = 1 / disable = 0 Uniflo in TZ Yes Chg Set
Mode (using a fixed pressure
instead of the pressure sensor)
Created Date: 2. April 2007 Rev. Date: 2. April 2007 Case no. TAE 1155
Init: TWF Topic group: Uniflo 1x00 Page 17 of 23
/conversion/tmp/scratch/437499433.doc
Uniflo 1x00 registers version 27

202 TZ pressure BarA 0118 REAL32 4 byte (single) 3 0.6 80 Pressure used as fixed pressure in Yes Chg Set
TZ Mode
203 Menu and alarm text - 0C00 Datablock 31768 bytes 3 Menu and alarm text for graphical Yes Set
(byte) display
204 Number of Slave units - 0000 0 No
205 Update EEPROM - 1E08 UINT16 (integer) 0 Command for storing all actual No Set
values to EEPROM
206 Name of alarm file - 1BAE STR22 22 byte (string) 3 Name of alarm text file Yes Set
207 Not used - 0000 UINT8 1 byte (byte) 0 0 10 Number of slaves connected to the No Set
communication card
208 Lock graphic display - 1E16 UINT8 1 byte (byte) 2 Command for disabling graphical No Set
display when updating menu files
209 Unlock graphic display - 1E18 UINT8 1 byte (byte) 2 Command for enabling graphical No Set
display after updating menu files
210 Volume control integer part m3 00B8 UINT32 4 byte (long) 3 0 99999999 The accumulated integer part of No Chg Live
measured volume.
211 Volume control decimal m3 00BC REAL32 4 byte (single) 3 0 0,9999999 The accumulated decimal part of No Chg Live
part measured volume for control.
212 Consumption in the actual Nm3 0240 UINT32 4 byte (long) Read Only 0 99999999 Consumption in the actual hour, No Live
hour, integer part integer part is the number of
converted m3 counted since the
start of the current hour.
213 Consumption in the actual Nm3 0244 REAL32 4 byte (single) Read Only 0 0,9999999 Consumption in the actual hour, No Live
hour, decimal part decimal part is the decimal value of
the above mentioned value
214 1. Max hour consumption Nm3 0248 TIME 4 bytes (yymmddhh) Read Only Time stamp for the highest No Live
time consumption in the month. The
timestamp is at the end of the hour.
215 1. Max hour consumption, Nm3 024C UINT32 4 byte (long) Read Only 0 99999999 Highest volume consumption, No Live
integer part integer part, in the month.
216 1. Max hour consumption, Nm3 0250 REAL32 4 byte (single) Read Only 0 0,9999999 Highest volume consumption, No Live
decimal part decimal part, in the month.
217 2. Max hour consumption Nm3 0254 TIME 4 bytes (yymmddhh) Read only Time stamp for the 2’nd highest No Live
time consumption in the month. The
timestamp is at the end of the hour.
218 2. Max hour consumption, Nm3 0258 UINT32 4 byte (long) Read Only 0 99999999 2’nd highest volume consumption, No Live
integer part integer part, in the month.
Created Date: 2. April 2007 Rev. Date: 2. April 2007 Case no. TAE 1155
Init: TWF Topic group: Uniflo 1x00 Page 18 of 23
/conversion/tmp/scratch/437499433.doc
Uniflo 1x00 registers version 27

219 2. Max hour consumption, Nm3 025C REAL32 4 byte (single) Read Only 0 0,9999999 2’nd highest volume consumption, No Live
decimal part decimal part, in the month.
220 3. Max hour consumption Nm3 0260 TIME 4 bytes (yymmddhh) Read Only Time stamp for the 3’rd highest No Live
time consumption in the month. The
timestamp is at the end of the hour.
221 3. Max hour consumption, Nm3 0264 UINT32 4 byte (long) Read Only 0 99999999 3’rd highest volume consumption, No Live
integer part integer part, in the month.
222 3. Max hour consumption, Nm3 0268 REAL32 4 byte (single) Read Only 0 0,9999999 3’rd highest volume consumption, No Live
decimal part decimal part, in the month.
223 Pressure calibration - 1CE6 4 byte Char Read Only Copy of Operator ID (Reg. 29) when Yes Live
operator Pressure calibration table is
updated
224 Temperature calibration - 1CEA 4 byte Char Read Only Copy of Operator ID (Reg. 29) when Yes Live
operator Temperature calibration table is
updated
225 Event log index - 00EC UINT16 2 bytes (integer) Read only Index pointer for Event log No Live
226 Alarm log index - 00EE UINT16 2 bytes (integer) Read only Index pointer for Alarm log No Live
227 Log interval Option 000D UINT8 1 byte (byte) 3 Time interval between the interval Yes Set
logs. For Option values see table
“Log interval description”
228 Interval of measurement Sec. 000A UINT8 1 byte (byte) 2 0 254 Interval between each Yes Set
measurement cycle. 0 = no
measurements
229 Daily log time Hour Hour 000B UINT8 1 byte (byte) 1 0 23 Time of the day for daily log Yes Set
230 Daily log time Hour Min. 000C UINT8 1 byte (byte) 1 0 59 Minute of the hour for daily log Yes Set
231 Interval log index - 0148 UINT16 2 bytes (integer) Read only Index pointer for the interval log No Live
232 Daily log index - 014A UINT16 2 bytes (integer) Read only Index pointer for the daily log No Live
233 Snapshot log index - 014C UINT16 2 bytes (integer) Read only Index pointer for the snapshot log No Live
234 Alarm triggered log index - 014E UINT16 2 bytes (integer) Read only Index pointer for the alarm triggered No Live
log
235 Display time Sec. 00C0 UINT8 1 byte (byte) 1 0 255 Time before the customer display Yes Set
returns to show the value of register
no. 1. 0 = no automatic return to
register no. 1.
236 Max pulse error Pulses 00C2 UINT8 1 byte (byte) 1 0 255 Maximum number of pulses in Yes Set
difference between LF input A and B
on “Pulse check every” number of
pulses before the alarm “Pulse
Created Date: 2. April 2007 Rev. Date: 2. April 2007 Case no. TAE 1155
Init: TWF Topic group: Uniflo 1x00 Page 19 of 23
/conversion/tmp/scratch/437499433.doc
Uniflo 1x00 registers version 27

count error” is raised


237 Pressure sensor is - 1F00 UINT16 (integer) 3 Command for notifying the event log No Always Set
changed about a pressure sensor change
238 Temperature sensor is - 1F02 UINT16 (integer) 3 Command for notifying the event log No Always Set
changed about a temperature sensor change
239 Month log width - 7016 UINT8 (byte) 1 Width of the month log (number of Yes Set
columns)
240 Month log size - 7014 UINT16 (integer) 3 Size of the month log (number of Yes Set
logs)
241 Month log register Data 7000 Datablock 20 byte (byte) 3 Setup table for month log. Each Yes Set
byte represents a column in the log
and is set to register number. Only
register under 256 can be used.
242 Month log index - 01F2 UINT16 2 bytes (integer) Read only Index pointer for the month log No Live
243 Display test - 1E1A UINT8 1 byte (byte) 2 Command for executing a display No Set
test of the customer display. The
display returns to normal mode after
next measurement.
244 Firmware address range - FFFF UINT8 1 byte (byte) 0 Used for validation of address range No Live
OK during Firmware update
245 Firmware update start - 1E1C UINT16 (integer) 3 Command for starting a Firmware No Always Set
upload. Making the Interval log
ready for receiving compressed
firmware. The data written is the
number of bytes to be transferred.
246 Firmware update end - 1E1E UINT16 (integer) 3 Command for decompressing and No Always Set
programming of downloaded
firmware to the programming
memory and restarting the Uniflo.
The data written is the checksum of
the program.
247 Firmware update cancel - 1E20 UINT16 (integer) 3 Command for restoring the setup of No Always Set
the Interval log and discontinuing
the firmware upload

Created Date: 2. April 2007 Rev. Date: 2. April 2007 Case no. TAE 1155
Init: TWF Topic group: Uniflo 1x00 Page 20 of 23
/conversion/tmp/scratch/437499433.doc
Uniflo 1x00 registers version 27

248 Program checksum - 0150 UINT16 (integer) Read only Checksum of the program, No Live
calculated by the Uniflo after
Firmware update. The configuration
tool uses the checksum to verify the
Firmware update. The checksum is
also used by the Uniflo to
continually monitor the Firmware for
faults (The total SW is scanned for
every 240 measuring cycles). If a
Firmware fault is detected the alarm
no. 19 “Firmware error” is set.
249 Temperature calibration - 0194 Datablock 30 bytes (byte) 3 Temperature calibration data Yes Always Set
table
250 Pressure calibration table - 01B2 Datablock 60 bytes (byte) 3 Pressure calibration data Yes Always Set
251 Force measurement - 1E22 UINT16 (integer) 0 Command for making a No Set
measurement out of the normal
measurement period. All volumes,
conversion factors, temperature and
pressure are updated
252 Pressure calibration time - 1CDA TIME 6 bytes Read Only Timestamp from Uniflo when Yes Live
(yymmddhhnnss) Pressure calibration table is
updated
253 Temperature calibration - 1CE0 TIME 6 bytes Read Only Timestamp from Uniflo when Yes Live
time (yymmddhhnnss) Temperature calibration table is
updated
254 Conversion table - 1CEE UINT16 (integer) 2 Checksum of Gas conversion table Yes Chg Set
checksum
255 Conversion table DLL - 1CF0 UINT16 (integer) 2 Conversion table DLL SW version Yes Chg Set
version

Created Date: 2. April 2007 Rev. Date: 2. April 2007 Case no. TAE 1155
Init: TWF Topic group: Uniflo 1x00 Page 21 of 23
/conversion/tmp/scratch/437499433.doc
Uniflo 1x00 registers version 27

Log reorganization description


Value Description
xxxxxxx1 (0x01) Reorganize interval log
xxxxxx1x (0x02) Reorganize 24 hour log
xxxxx1xx (0x04) Reorganize snap shot log
xxxx1xxx (0x08) Reorganize alarm activate log
xxx1xxxx (0x10) Initiate measurement

Log interval description


Value Description
0 Interval log disable
1 Log interval = 1 min
2 Log interval = 2 min
3 Log interval = 5 min
4 Log interval = 15 min
5 Log interval = 30 min
6 Log interval = 1 hour
7 Log interval = 2 hour
8 Log interval = 4 hour

Pulse out diversion factor X description


Value Description
0 Division factor = 0.1
1 Division factor = 1
2 Division factor = 10
3 Division factor = 100

Pulse output period cycle time description


Value Description
0 Period time = 30 msec
1 Period time = 60 msec
2 Period time = 125 msec
3 Period time = 250 msec
4 Period time = 500 msec

Created Date: 2. April 2007 Rev. Date: 2. April 2007 Case no. TAE 1155
Init: TWF Topic group: Uniflo 1x00 Page 22 of 23
/conversion/tmp/scratch/437499433.doc
Uniflo 1x00 registers version 27

AD-Amplify description
Value Description
0 Amplifying = 1
1 Amplifying = 2

Pulse out X enable description


Value Description
0 Pulse out disabled
1 Pulse out enabled

Pressure sensor source description


Value Description
0 Internal sensor only
1 External sensor from PT option board
2 External sensor from PT option board with Internal sensor as backup at power fail

Temperature sensor source description


Value Description
0 Internal sensor only
1 External sensor from PT option board
2 External sensor from PT option board with Internal sensor as backup at power fail

Gas calculation formula


Value Description
0 AGA NX-19 MOD CORR
1 AGA 8
2 SGERG 88
3 Z/Zb
4 AGA NX-19 MOD HER/WOL

Created Date: 2. April 2007 Rev. Date: 2. April 2007 Case no. TAE 1155
Init: TWF Topic group: Uniflo 1x00 Page 23 of 23