Sei sulla pagina 1di 22

MEASUREMENT INSTRUMENTATION

Sumário
Flow................................................................................................................................................................................... 2
Magnetic........................................................................................................................................................................ 2
Vortex............................................................................................................................................................................ 5
Coriolis.......................................................................................................................................................................... 9
Transmitters ................................................................................................................................................................ 11
Density ............................................................................................................................................................................ 11
Fork Density Meter..................................................................................................................................................... 12
Viscosity.......................................................................................................................................................................... 12
Fork Viscosity Meter.................................................................................................................................................. 12
Pressure ........................................................................................................................................................................... 12
Rosemount™ 2088 Gage and Absolute Pressure Transmitter ................................................................................ 12
Rosemount™ 2090F Hygienic Pressure Transmitter............................................................................................... 13
Rosemount™ 2051 Pressure Transmitter ................................................................................................................. 13
Rosemount™ 3051P In-Line Pressure Transmitter ................................................................................................. 14
Rosemount™ 3051S Series of Instrumentation ....................................................................................................... 15
Manifolds .................................................................................................................................................................... 16
Continuous Level............................................................................................................................................................ 16
Rosemount™ 1199 Diaphragm Seal System............................................................................................................ 16
Rosemount™ 2051L Level Transmitter ................................................................................................................... 17
Rosemount™ 3051L Level Transmitter ................................................................................................................... 17
Rosemount™ 3051SAL Level Transmitter .............................................................................................................. 17
Rosemount™ 3100 Level Transmitter – Ultrasonic ................................................................................................ 18
Rosemount™ 5300 Level Transmitter - Guided Wave Radar ................................................................................ 18
Rosemount™ 5400 Level Transmitter - Non-Contacting Radar............................................................................. 19
Point Level Detection..................................................................................................................................................... 20
Rosemount™ 2110 Level Switch - Vibrating Fork ................................................................................................. 20
Rosemount™ 2120 Level Switch - Vibrating Fork ................................................................................................. 20
Rosemount™ 2130 Level Switch - Vibrating Fork ................................................................................................. 20
Rosemount™ 2140 Level Detector - Vibrating Fork............................................................................................... 20
Temperature .................................................................................................................................................................... 21
Transmitters ................................................................................................................................................................ 21
Sensors ........................................................................................................................................................................ 21
Flow
Magnetic
Measures the volumetric flow of liquid and slurries only. Fluid must be conductive, conductivity of 5
microsiemens/cm or greater.
Magmeters offer no obstruction, which make them ideal for a range of applications, from clean and sanitary liquids to
slurries and abrasives and corrosives fluids.
These meters are vulnerable to electromagnetic interference.

Rosemount 8750W Magnetic Flow Meters for Utility Water and Wastewater (águas residuais)
Applications
For utility water and wastewater;
Flanged process connections Welded coil housing;
½-in. to 48-in.;

Standard, reference, and bullet-nose electrodes available.


Table 1: Sizing guidelines

Application Velocity Range (m/s)


Normal Service 0 – 12
Preferred Service 0.6 – 6.1

Table 2: Process temperature limits

Lining Material Temperature Range (°C)


PTFE -50 to 177
Polyurethane -18 to 60
Neoprene -18 to 80

Flange Rating: up to 300#.

Rosemount 8705 Flanged Magnetic Flow Meter Sensors


Service: conductive liquids and slurries;
½-in to 36-in;
Pulse DC technology;

Standard, grounding, and bullet-nose electrodes available.


Table 3: Sizing guidelines

Application Velocity Range (m/s)


Normal Service 0 – 12
Preferred Service 0.6 – 6.1
Abrasive Slurries 0.9 – 3.1
Non-Abrasive Slurries 1.5 – 4.6

Table 4: Process temperature limits

Lining Material Temperature Range (°C)


PTFE -29 to 177
ETFE -29 to 149
PFA -29 to 177
Polyurethane -18 – 60
Neoprene -18 to 80
Linatex -18 to 70
Extreme service polyurethane -18 to 39
Extreme service PFA -29 to 177

Flange Rating: up to 2500#.

Rosemount 8707 High-Signal Magnetic Flowmeter Sensor


Service: conductive liquids and slurries;
High signal sensor;
Flanged Process System Sensor;

Welded, sealed coil housing;

3-in. to 36-in.;
High current pulsed DC technology ideal for high solids or slurry applications;

Standard, grounding, and bullet-nose electrodes available.


The 8707 High-Signal Sensor, used in conjunction with the 8712H High-Signal Transmitter, forms the Rosemount
High-Signal Magnetic Flowmeter System.
Table 5: Sizing guidelines

Application Velocity Range (m/s)


Normal Service 0 – 12
Preferred Service 0.6 – 6.1
Abrasive Slurries 0.9 – 3.1
Non-Abrasive Slurries 1.5 – 4.6

Table 6: Process temperature limits

Lining Material Temperature Range (°C)


PTFE -29 to 177
ETFE -29 to 149
PFA -29 to 177
Polyurethane -18 – 60
Neoprene -18 to 80
Linatex -18 to 70
Extreme service polyurethane -18 to 39
Extreme service PFA -29 to 177

Flange Rating: up to 2500#.

Rosemount 8711 wafer sensor


Service: conductive liquids and slurries;
Wafer (flangeless) design;
Economical, compact, and lightweight alternative to flanged sensors;
0.15-in. to 8-in.;

Pulsed DC technology;
Standard, grounding, and bullet-nose electrodes available;
Table 7: Sizing guidelines

Application Velocity Range (m/s)


Normal Service 0 – 12
Preferred Service 0.6 – 6.1
Abrasive Slurries 0.9 – 3.1
Non-Abrasive Slurries 1.5 – 4.6

Table 8: Process temperature limits

Lining Material Temperature Range (°C)


PTFE -29 to 177
ETFE -29 to 149
PFA -29 to 177

Flange Rating: up to 300#.

Rosemount 8721 sanitary sensor


Service: conductive liquids and slurries;
Hygienic sensor;

Designed for food, beverage, and pharmaceutical applications;


3-A and EHEDG certified;

½-in. to 4-in.;
Pulsed DC technology;
Variety of industry standard process connections;
Suitable for CIP/SIP.
Table 9: Sizing guidelines

Application Velocity Range (m/s)


Normal Service 0 – 12
Preferred Service 0.6 – 6.1
Abrasive Slurries 0.9 – 3.1
Non-Abrasive Slurries 1.5 – 4.6

Table 10: Process temperature limits

Lining Material Temperature Range (°C)


PFA -29 to 177
Maximum working pressure: 300 psi.

Rosemount 8714D Transmitter Calibration Standard


Simulated flow: 0; 0.91; 3.06; 9,14 m/s

Rosemount 8712E Wall Mount Magnetic Flow Meter Transmitters


Remote mount transmitter;
Easy to use LOI with dedicated configuration buttons;
Advanced Diagnostics available;

Perfect for wall or panel mount.

Rosemount 8732E Field Mount Magnetic Flow Meter Transmitters


Ideal for integral mount transmitter installations
HART / Analog, FOUNDATION fieldbus, or PROFIBUS PA fieldbus output available;

Advanced Diagnostics available;


Optical Switch LOI;

Optional DI/DO (digital input / digital output) available (HART only).

Rosemount 8712H Slurry Magnetic Flow Meter Transmitters


Remote mount transmitter;
High-Signal Pulsed DC for use with the High-Signal 8707 Sensor;

Ideal for high solid applications - mining/pulp stock/other slurries;


120 VAC power only;

Not CE Marked.

Vortex
They are volumetric flowmeter, based on the principle of Von Kármán. The volumetric flow is in direct proportion of
the frequency of the vortex formed.
𝑓𝑓
𝑄𝑄 =
𝑘𝑘
Where 𝑄𝑄 is the volumetric flow, 𝑓𝑓 is the vortex shedding frequency, and 𝑘𝑘 is a factor dependent of the geometry and
Reynolds Number.
𝜌𝜌𝑣𝑣 𝐷𝐷
𝑅𝑅𝑅𝑅 =
𝜇𝜇
Where 𝑅𝑅𝑅𝑅 is Reynolds Number, 𝜌𝜌𝑣𝑣 flow velocity, 𝐷𝐷 is the diameter of the tube, and 𝜇𝜇 is the dynamic viscosity.

The flowmeter should be located in a place where vibration and electrical interference levels are low. Both of these
influences can decrease the signal-to-noise ratio at the input to the transmitter. This reduction can degrade the ability
of the meter to measure low flows.
Process fluids: liquid, gas, and steam applications.

Rosemount 8600 Utility Vortex Flow Meters


Process fluids: liquid, gas, and steam applications. Fluids must be homogeneous and single-phase.
Line Size 1-in to 8-in;
Operating Temperatures: -50°C to 250°C;
Turndown 30:1;

Wetted Material: Stainless Steel – CF3M & CF8M;


Minimum measurable meter Reynolds Numbers: 5000 minimum.
Table 11: Minimum Measurable Meter Velocities

Fluids m/s
Liquids �54/𝜌𝜌
Gases �54/𝜌𝜌
The 𝜌𝜌 is the process fluid density at flowing conditions in 𝑘𝑘𝑘𝑘/𝑚𝑚3 .
Table 12: Maximum Measurable Meter Velocities

Fluids m/s
Liquids �134,000/𝜌𝜌 or 7.6
Gases �134,000/𝜌𝜌 or 76
The 𝜌𝜌 is the process fluid density at flowing conditions in 𝑘𝑘𝑘𝑘/𝑚𝑚3 .

Flange Rating: up to 300#.

Rosemount 8800 Series Vortex Flow Meters


Process fluids: liquid, gas, and steam applications. Fluids must be homogeneous and single-phase.;
Turndown 38:1;

Line Size: Flanged ½-in to 12-in;


Wafer: ½-in to 8-in;
Dual: ½-in to 12-in;

Reducer: 1-in to 14-in;


Wetted Material: Stainless Steel – 316 / 316L and CF3M

Nickel Alloy – C-22 and CW2M


High Temp Carbon Steel – A105 and WCB
Low Temp Carbon Steel – LF2 and LCC

Duplex UNS S32760 and 6A


Operating Temperature: -200°C to 450°C;

Minimum measurable meter Reynolds Numbers: 5000 minimum.


Table 13: Minimum Measurable Meter Velocities

Fluids m/s
Liquids �54/𝜌𝜌
Gases �54/𝜌𝜌
The 𝜌𝜌 is the process fluid density at flowing conditions in 𝑘𝑘𝑘𝑘/𝑚𝑚3 .
Table 14: Maximum Measurable Meter Velocities

Fluids m/s
Liquids �134,000/𝜌𝜌 or 7.6
Gases �134,000/𝜌𝜌 or 91.4
The 𝜌𝜌 is the process fluid density at flowing conditions in 𝑘𝑘𝑘𝑘/𝑚𝑚3 .
Flange Rating: up to 1500#.

Rosemount 8800 MultiVariable Flow Meters


Process fluids: liquid, gas, and steam applications. Fluids must be homogeneous and single-phase.;
Incorporates temperature sensor into the vortex meter;
Turndown 38:1;
Line Size: Flanged ½-in to 12-in;

Wafer: ½-in to 8-in;


Dual: ½-in to 12-in;

Reducer: 1-in to 14-in;


Wetted Material: Stainless Steel – 316 / 316L and CF3M
Nickel Alloy – C-22 and CW2M
High Temp Carbon Steel – A105 and WCB

Low Temp Carbon Steel – LF2 and LCC

Duplex UNS S32760 and 6A


Operating Temperature: -200°C to 450°C;
Minimum measurable meter Reynolds Numbers: 5000 minimum.
Table 15: Minimum Measurable Meter Velocities

Fluids m/s
Liquids �54/𝜌𝜌
Gases �54/𝜌𝜌
The 𝜌𝜌 is the process fluid density at flowing conditions in 𝑘𝑘𝑘𝑘/𝑚𝑚3 .
Table 16: Maximum Measurable Meter Velocities

Fluids m/s
Liquids �134,000/𝜌𝜌 or 7.6
Gases �134,000/𝜌𝜌 or 91.4
The 𝜌𝜌 is the process fluid density at flowing conditions in 𝑘𝑘𝑘𝑘/𝑚𝑚3 .

Flange Rating: up to 1500#.

Rosemount 8800 Reducer Vortex Flow Meters


Process fluids: liquid, gas, and steam applications. Fluids must be homogeneous and single-phase.;
Improve low-flow-rate measurement performance with a smart reducer design;
Turndown 38:1;
Line Size: 1-in to 12-in;
Wetted Material: Stainless Steel – 316 / 316L and CF3M

Nickel Alloy – C-22 and CW2M


High Temp Carbon Steel – A105 and WCB
Low Temp Carbon Steel – LF2 and LCC
Duplex UNS S32760 and 6A
Operating Temperature: -200°C to 450°C;
Minimum measurable meter Reynolds Numbers: 5000 minimum.
Table 17: Minimum Measurable Meter Velocities

Fluids m/s
Liquids �54/𝜌𝜌
Gases �54/𝜌𝜌
The 𝜌𝜌 is the process fluid density at flowing conditions in 𝑘𝑘𝑘𝑘/𝑚𝑚3 .
Table 19: Maximum Measurable Meter Velocities

Fluids m/s
Liquids �134,000/𝜌𝜌 or 7.6
Gases �134,000/𝜌𝜌 or 91.4
The 𝜌𝜌 is the process fluid density at flowing conditions in 𝑘𝑘𝑘𝑘/𝑚𝑚3 .

Flange Rating: up to 900#.

Rosemount 8800 CriticalProcess Vortex Flow Meters


Process fluids: liquid, gas, and steam applications. Fluids must be homogeneous and single-phase;
Unique design isolates Vortex sensor from the process, enabling safe, on-line sensor replacement for maximum
uptime;

Turndown 38:1;
Line Size: Flanged ½-in to 12-in;

Wafer: ½-in to 8-in;


Dual: ½-in to 12-in;

Reducer: 1-in to 14-in;


Wetted Material: Stainless Steel – 316 / 316L and CF3M
Nickel Alloy – C-22 and CW2M
High Temp Carbon Steel – A105 and WCB
Low Temp Carbon Steel – LF2 and LCC

Duplex UNS S32760 and 6A


Operating Temperature: -200°C to 450°C;
Minimum measurable meter Reynolds Numbers: 5000 minimum.
Table 13: Minimum Measurable Meter Velocities

Fluids m/s
Liquids �54/𝜌𝜌
Gases �54/𝜌𝜌
The 𝜌𝜌 is the process fluid density at flowing conditions in 𝑘𝑘𝑘𝑘/𝑚𝑚3 .
Table 14: Maximum Measurable Meter Velocities

Fluids m/s
Liquids �134,000/𝜌𝜌 or 7.6
Gases �134,000/𝜌𝜌 or 91.4
The 𝜌𝜌 is the process fluid density at flowing conditions in 𝑘𝑘𝑘𝑘/𝑚𝑚3 .

Flange Rating: up to 1500#.

Coriolis
Coriolis meters are mass flowmeters, and density meters.
Coriolis meters can measure more than one process variable. Besides mass flow, they can also measure density,
temperature, and viscosity.

They are virtually unaffected by changes in fluid pressure, temperature, viscosity, and density. As a result, Coriolis
meters can be used on a variety of process fluids without recalibration and without compensating for parameters
specific to a particular type of fluid.

Coriolis meters have the highest accuracy of all types of flowmeters. Because Coriolis meters measure mass flow
directly, they have fewer sources of errors.
The time difference between the waves is measured and is directly proportional to the mass flow rate.

A change in the mass of the fluid contained inside the tubes causes a corresponding change to the tube natural
frequency. The frequency change of the tube is used to calculate density.

Coriolis meters have no Reynolds number constraints, and can be applied to almost any liquid or gas flowing at a
sufficient mass flow to affect vibration of the flowmeter. Typical liquid applications include foods, slurries, harsh
chemicals, and blending systems.

Overview
ELITE

• Peak performance Coriolis meter


• Ultimate real-world performance
• Best fit-for-application
• Superior measurement confidence

T-Series

• Straight tube full-bore Coriolis meter


• Superior flow measurement in a single straight tube flow meter
• Comprehensive hygienic application coverage
• Superior reliability
F-Series

• High performance compact drainable Coriolis meter


• Best flow and density measurement in a compact, drainable flow meter
• Broadest range of application coverage
• Superior reliability and safety
R-Series

• General purpose flow-only Coriolis meter


• Simple to install and easy to use Coriolis flow measurement
• Broadest range of application coverage
• Superior reliability
• H-Series
Hygienic compact drainable Coriolis meter
• Best flow and density measurement in a compact hygienic flow meter
• Comprehensive hygienic application coverage
• Superior reliability
LF-Series

• Extreme low-flow Coriolis meter


• Highest precision miniaturized flow meter
• Scalable platform for the most demanding low-flow applications
• Superior reliability
CNG-Series

• Compressed Natural Gas (CNG) Coriolis meter


• Specifically designed for both light and heavy duty vehicle dispensers
• Custody transfer approved
• Compact design with no moving parts, special mounting, or flow conditioning required

HPC010P

• Ultra-High Pressure Flowmeter


• Global industry standard for ultra high pressure environments
• A Coriolis mass flow meter designed for high pressure environments up to 15,000 psi (1034 bar), such as
chemical injection for the oil and gas industry
• Micro Motion MVD™
• Direct Connect™ technology for space and weight savings
• Variety of transmitter options provide multivariable outputs to accommodate any design requirements
• Compact design with no moving parts, no special mounting, or flow conditioning required

Micro Motion R-Series General Purpose Coriolis Flow and Density Meters
They are ideally suited for general purpose applications that typically require repeatable, reliable, low-maintenance
measurements;

Basic liquid mass flow, volume flow, and density measurement performance in a compact design;
Line Size: 1/4" (DN6) - 2" (DN50);
Pressure Range: up to 1450 psig (100 barg);
Temperature Range: -100 to 150°C;
Turndown 20:1
Table 15: Maximum flow rate limits

Mass Volume
Liquids 87,100 kg/h 87,100 l/h;
Gases 18,137 kg/h 25,515 Nm3/h

Micro Motion F-Series Compact, Drainable Coriolis Flow and Density Meters
Delivering highly reliable and robust measurement, F-Series flow meters are the preferred choice for process control
applications.
Achieve highly accurate mass volume flow and density measurement in applications that require a compact, drainable
design
Line Size: 1/4" (DN6) - 3" (DN80);

Pressure Range: up to 6250 psig (430 barg);


Temperature Range: -100 °C to 350 °C;

Turndown: 20:01;
Table 16: Maximum flow rate limits

Mass Volume
Liquids 272,000 kg/h 272,000 l/h;
Gases 47,505 kg/h 66,829 Nm3/h

Transmitters
Density
Tuning Fork Densitometers

𝑅𝑅𝑅𝑅𝑅𝑅𝑅𝑅𝑅𝑅𝑅𝑅𝑅𝑅𝑅𝑅 𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓𝑓 = �𝐾𝐾/(𝑀𝑀 + 𝑘𝑘𝑘𝑘)

Where K is the system stiffness, M is the transducer mass, k is the system constant, and 𝜌𝜌 is the fluid density.
These densitometers make use of the natural frequency of low-mass tuning forks. In some cases, the fluid is taken into
a small chamber in which the electromechanically driven forks are situated. In other cases, the fork is inserted directly
into the liquid. Calibration is necessary in each application.

The advantages of vibrating element meters include:


1. They are suitable for both liquids and gases with reasonable accuracy.
2. They can be designed for real-time measurements.
3. They can easily be interfaced because they operate on frequencies and are inherently digital.
4. They are relatively robust and easy to install.

5. Programmable and computerized versions are available. Programmed versions make all the corrections
automatically. They provide the output of live density, density at reference conditions, relative density, specific
gravity, concentration, solid contents, etc.
The disadvantages include:
1. They do not relate directly to primary measurements; therefore, they must be calibrated.
2. They all have problems in measuring multiphase liquids.

Fork Density Meter


Operating Range 0–3000 kg/m3 (0–3 g/cm3)
Density Accuracy ±1.0 kg/m3 (±0.001 g/cm3)
Density Repeatability ±0.1 kg/m3 (±0.0001 g/cm3)

Process Viscosity effect No effect for 0–50 cP (±4 kg/m3 (±0.004 g/cm3) for 50–200 cP)
Process Temperature Effect (Corrected) ±0.1 kg/m3 per °C (±0.0001 g/cm3 per °C)
Temperature Range –50 °C to +200 °C (–58 °F to +392 °F)
Pressure Range 207 bar (3000 psi)

Viscosity

Fork Viscosity Meter


Receive reliable and continuous multivariable measurement of viscosity, density and temperature;
Integral HART I/O direct input of external temperature, pressure, and flow measurements provide enhanced readings.

• Dynamic viscosity
• Kinematic viscosity
• Referred viscosity
• Density
• Referred Density/Specific Gravity
• °API

Operating Range 0.5 to 20,000 cP


Viscosity Accuracy ±0.2 cP (0.5 –10 cP range) then ±1% full scale
Viscosity Repeatability ±0.5% of reading
Density Accuracy ±1 kg/m3 (±0.001 g/cm3)

Density Repeatability ±0.1 kg/m3 (±0.0001 g/cm3)


Temperature Range –50 °C to +200 °C (–58 °F to +392 °F)

Pressure Range 207 bar (3000 psi)

Pressure
Rosemount™ 2088 Gage and Absolute Pressure Transmitter
Service: Liquid, gas, and vapor applications

Rangedown Up to 50:1
Communication Protocol 4-20 mA HART®, 1-5 V Low Power HART®

Measurement Range Up to 4,000 psig (275,8 bar) Gage, Up to 4,000 psia (275,8 bar) Absolute

Process Wetted Material 316L SST, Alloy C-276


Diagnostics Basic Diagnostics

Rosemount™ 2090F Hygienic Pressure Transmitter


Services applications: liquid, gas, vapor, and high-viscosity.

Rangedown Up to 20:1
Communication Protocol 4-20 mA HART®
Measurement Range Up to 300 psig (20,7 bar) Gage, Up to 300 psia (20,7 bar) Absolute

Process Wetted Material 316L SST


Diagnostics Basic Diagnostics
Certifications/Approvals 3-A Sanitary Standards, hazardous location, see full specs for complete list of certifications

Rosemount™ 2051 Pressure Transmitter


Rosemount™ 2051 In-Line Pressure Transmitter
Rangedown Up To 100:1
Communication Protocol 4-20 mA HART®, WirelessHART®, FOUNDATION™ Fieldbus, PROFIBUS®, 1-5 V
Low Power HART®
Measurement Range Up to 10000 psig (689,47 bar) Gage, Up to 10000 psia (689,47bar) Absolute
Process Wetted Material 316L SST, Alloy C-276

Diagnostics Basic Diagnostics

Rosemount™ 2051 Differential Pressure Flow Transmitter


Rangedown Up To 100:1
Measurement Range Up to 2000 psi (137,9 bar) differential

Output Differential pressure, scaled variable


Communication Protocol 4-20 mA HART®, WirelessHART®, FOUNDATION™ Fieldbus, PROFIBUS®, 1-5 V
Low Power HART®
Process Wetted Material 316L SST, Alloy C-276, Tantalum

Diagnostics Basic Diagnostics

Rosemount™ 2051 Coplanar™ Pressure Transmitter


Rangedown Up To 100:1
Communication Protocol 4-20 mA HART®, WirelessHART®, FOUNDATION™ Fieldbus, PROFIBUS®, 1-5 V
Low Power HART®
Measurement Range Up to 2000 psi (137,9 bar) Differential, Up to 2000 psig (137,9 bar) Gage

Process Wetted Material 316L SST, Alloy C-276, Tantalum


Diagnostics Basic Diagnostics

Rosemount™ 2051HT Hygienic Pressure Transmitter


Rangedown Up To 50:1

Communication Protocol 4-20 mA HART®, FOUNDATION™ Fieldbus


Measurement Range Up to 300 psig (20,7 bar) Gage, Up to 150 psia (10,3 bar) Absolute
Process Wetted Material 316L SST mechanically polished and electropolished to Ra < 30 µ-in. (0.81 µ-m)
Diagnostics Basic Diagnostics

Rosemount™ 3051P In-Line Pressure Transmitter


Rosemount™ 3051 In-Line Pressure Transmitter
Rangedown Up to 150:1
Communication Protocol 4-20 mA HART, WirelessHART®, FOUNDATION fieldbus, Profibus, 1-5 V Low Power
HART

Measurement Range Up to 20000 psig (1378,95 bar) Gage, Up to 20000 psia (1378,95 bar) Absolute
Process Wetted Material 316L SST, Alloy C-276
Diagnostics Basic Diagnostics, Power Advisory Diagnostics

Rosemount™ 3051 Differential Pressure Flow Transmitter


Rangedown Up to 150:1
Measurement Range Up to 2000 psi (137,89 bar) differential

Output Differential pressure, scaled variable

Communication Protocol 4-20 mA HART®, WirelessHART®, FOUNDATION™ Fieldbus, PROFIBUS®, 1-5 V


Low Power HART®

Process Wetted Material 316L SST, Alloy C-276, Alloy 400, Tantalum, Gold-plated Alloy 400, Gold-plated 316L
SST
Diagnostics Basic Diagnostics, Power Advisory Diagnostics

Rosemount™ 3051HT Hygienic Pressure Transmitter


Rangedown Up To 100:1
Communication Protocol 4-20 mA HART®, FOUNDATION™ Fieldbus

Measurement Range Up to 300 psig (20,7 bar) Gage, Up to 150 psia (10,3 bar) Absolute
Process Wetted Material 316L SST mechanically polished and electropolished to Ra < 15 µ-in. (0.38 µ-m)

Diagnostics Basic Diagnostics, Power Advisory Diagnostics

Rosemount™ 3051 Coplanar™ Pressure Transmitter


Rangedown Up to 150:1
Communication Protocol 4-20 mA HART, WirelessHART®, FOUNDATION fieldbus, Profibus, 1-5 V Low Power
HART
Measurement Range Up to 2000psi (137,89 bar) Differential, Up to 2000psig (137,89 bar) Gage, Up to 4000psia
(275,79 bar) Absolute
Process Wetted Material 316L SST, Alloy C-276, Alloy 400, Tantalum, Gold-plated Alloy 400, Gold-plated 316L
SST

Diagnostics Basic Diagnostics, Power Advisory Diagnostics


Rosemount™ 3051S Series of Instrumentation
The all-welded hermetic SST design delivers the industry's highest field reliability.
Ultra performance provides up to ±0.025% accuracy and 200:1 rangedown.
Ultra for Flow performance provides up to ±0.04% of reading and 14:1 flow turndown.

Rosemount™ 3051S Coplanar™ Pressure Transmitter


Rangedown Up to 200:1
Communication Protocol 4-20 mA HART, WirelessHART®, FOUNDATION fieldbus
Measurement Range Up to 2000psi (137,89 bar) Differential, Up to 2000psig (137,89 bar) Gage, Up to 4000psia
(275,79 bar) Absolute
Process Wetted Material 316L SST, Alloy C-276, Alloy 400, Tantalum, Gold-plated Alloy 400, Gold-plated 316L
SST
Diagnostics Basic Diagnostics, Power Advisory Diagnostics, Advanced Diagnostics

Rosemount™ 3051S In-Line Pressure Transmitter


Rangedown Up to 200:1
Communication Protocol 4-20 mA HART, WirelessHART®, FOUNDATION fieldbus

Measurement Range Up to 10000psi (689,47 bar) Gage, Up to 10000psia (689,47 bar) Absolute
Process Wetted Material 316L SST, Alloy C-276

Diagnostics Basic Diagnostics, Power Advisory Diagnostics, Advanced Diagnostics

Rosemount™ 3051S MultiVariable™ Transmitter


It obtains measurement combinations of differential pressure, static pressure and process temperature.
Rangedown Up to 200:1

Communication Protocol 4-20 mA HART®, WirelessHART®, FOUNDATION™ Fieldbus


Measurement Range Up to 2000 psi (137,89 bar) differential, Up to 3626 psi (250,00 bar) static
Process Wetted Material 316L SST, Alloy C-276, Tantalum, Gold-plated 316L SST
Diagnostics Basic Diagnostics

Process Wetted Material 316L SST, Alloy C-276, Tantalum, Gold-plated 316L SST
Diagnostics Basic Diagnostics

Rosemount™ 3051S High Static DP Transmitter


SuperModule design withstands static lines pressures of up to 15,000 psi (1,034 bar);

Rangedown Up to 150:1
Communication Protocol 4-20 mA HART, WirelessHART®, FOUNDATION™ Fieldbus
Measurement Range Up to 150 psi (10.34 bar) Differential with maximum working pressure up to 15,000 psi (1034
bar)
Process Wetted Material Alloy C-276
Diagnostics Basic Diagnostics, Power Advisory Diagnostics, Advanced Diagnostics

Manifolds
Rosemount™ 304 Conventional Manifold
Attaches to a transmitter with a traditional or coplanar flange;
Designed for multivariable, static and differential pressure transmitters, this manifold allows instrument isolation,
controlled venting and protection from leaking to ensure measurement integrity;
2-,3- and 5-valve configuration for assembly to multi-variable, absolute, gage and differential pressure transmitters;
Maximum Operating Temperature 1000°F (538°C)
Manifold Material 316 SST/316L SST, Carbon Steel

Packing Material PTFE, Graphite-based


Process Connections 1/2"-14 female NPT, IEC 61518
Process Connection Orientation Parallel transmitter, 90° transmitter

Rosemount™ 305 Integral Manifold


Can be used with multivariable, static and differential pressure transmitters.
Designed for direct assembly to Rosemount Coplanar transmitter interface, eliminating the need for a flange;

2-,3- and 5-valve configuration for multivariable, absolute, gage and differential pressure transmitters;
Maximum Operating Temperature 1000°F (538°C)

Manifold Material 316 SST/316L SST, Alloy C-276, Alloy 400


Packing Material PTFE, graphite-based

Process Connections 1/4"�-18 NPT female, 1/2"�-14 NPT female, 1/2"�-14 female NPT flange adapter, 12 mm
ferrule tube flange adapter
Process Connection Orientation Parallel with transmitter, 90° to transmitter

Rosemount™ 306 In-Line Manifold


Assembles directly to in-line pressure transmitters and gauges for simple in-process calibration

Block-and-bleed and 2-valve configurations provide instrument isolation and drain/vent capabilities
Maximum Operating Temperature 1000°F (538°C)
Manifold Material 316 SST/316L SST, Alloy C-276, Alloy 400
Packing Material PTFE, Graphite-based

Process Connections 1/2"�-14 male NPT, 1/2"�-14 female NPT

Process Connection Orientation Parallel with transmitter

Continuous Level
Rosemount™ 1199 Diaphragm Seal System
eal System Type Direct Mount, Remote Mount, Tuned-System, Balanced System

Transmitter Connection Welded-Repairable, All Welded


Process Connection Flanged: ANSI/ASME, EN/DIN, GOST, & JIS

�Threaded: NPT, DIN, ISO

�Hygienic
Process Wetted Material 316L SST, Alloy C-276, Alloy 400, Tantalum, Gold-plated Alloy 400, Gold-plated 316L
SST, see PDS for full list of materials

Rosemount™ 2051L Level Transmitter


Differential pressure level transmitter;
Max. Operating Pressure Up to 300 psi (20,68 bar)
Process Temperature Range Based on fill fluid - Maximum 401°F (205°C), Minimum -157°F (-105°C)

Communication Protocol 4-20 mA HART®, WirelessHART®, FOUNDATION™ Fieldbus, PROFIBUS®, 1-5 V


Low Power HART®
Seal System Type Direct Mount, Tuned-System
Transmitter Connection Welded-Repairable
Process Connection Flanged: ANSI/ASME, EN/DIN, JIS

Process Wetted Material 316L SST, Alloy C-276, Tantalum


Diagnostics Basic Diagnostics

Rosemount™ 3051L Level Transmitter


Differential pressure level transmitter;
Max. Operating Pressure Up to 300 psi (20,68 bar)

Process Temperature Range Based on fill fluid - Maximum 401°F (205°C), Minimum -157°F (-105°C)
Communication Protocol 4-20 mA HART®, WirelessHART®, FOUNDATION™ Fieldbus, PROFIBUS®, 1-5 V
Low Power HART®
Seal System Type Direct Mount, Tuned-System

Transmitter Connection Welded-Repairable


Process Connection Flanged: ANSI/ASME, EN/DIN, JIS
Process Wetted Material 316L SST, Alloy C-276, Tantalum
Diagnostics Basic Diagnostics, Power Advisory Diagnostics

Rosemount™ 3051SAL Level Transmitter


Extreme conditions of temperature and pressure;

Differential pressure level transmitter;


Max. Operating Pressure Up to 10,000psi (689.48 bar)
Process Temperature Range Based on fill fluid - Maximum 770°F (410°C), Minimum -157°F (-105°C)
Communication Protocol 4-20 mA HART®, WirelessHART®, FOUNDATION™ Fieldbus
Seal System Type Direct Mount, Remote Mount, Tuned-System, Balanced System
Transmitter Connection Welded-Repairable, All Welded
Process Connection Flanged: ANSI/ASME, EN/DIN, GOST, & JIS

�Threaded: NPT, DIN, ISO

�Hygienic
Process Wetted Material 316L SST, Alloy C-276, Alloy 400, Tantalum, Gold-plated Alloy 400, Gold-plated 316L
SST, see full specs for complete list of materials
Diagnostics Basic Diagnostics, Power Advisory Diagnostics, Advanced Diagnostics

Rosemount™ 3100 Level Transmitter – Ultrasonic


Suitable for storage tanks, effluent pits, buffer tanks, and open channel flow.
Operating Temperature -22 to 158 °F (-30 to 70 °C)
Communication Protocol 4–20 mA/HART®

Temperature compensation is integrated and you can equip the Rosemount 3100 with an external sensor for dynamic
temperature compensation.

Application Model Range (m)


Simple level measurement 3101 8
3102 11
Level measurement and local relays 3102 11
Level measurement in hazardous 3105 11
areas
Open channel flow or volume 3102 Non-hazardous area
measurement 3105 Hazardous area

Rosemount™ 3300 Level Transmitter - Guided Wave Radar


The Rosemount 3300 has no moving parts, needs no calibration, and is virtually unaffected by process conditions.
Suitable for small tanks, difficult tank geometry, and interfering obstacles;

Operating Pressure Full vacuum to 580 psi (Full vacuum to 40 bar)


Operating Temperature -40 to 302°F (-40 to 150°C)
Communication Protocol 4-20 mA/HART™, Modbus®

Probe Types Rigid single lead, Segmented single lead, Flexible single lead, Flexible twin lead, Coaxial, PTFE coated
probes

3301 Guided Wave Radar Level Transmitter (interface available for fully submerged probe) ★
3302 Guided Wave Radar Level and Interface Transmitter
Rosemount™ 5300 Level Transmitter - Guided Wave Radar
The Rosemount 5300 Level Transmitter is ideal for challenging measurements on liquids, slurries, and solids, offering
state of the art reliability and safety features in level and interface applications.
5301 Guided Wave Radar Liquid Level or Interface Transmitter (interface available for fully
submerged probe)
5302 Guided Wave Radar Liquid Level and Interface Transmitter
5303 Guided Wave Solids Level Transmitter
Rosemount™ 5400 Level Transmitter - Non-Contacting Radar
The Rosemount 5400 Level Transmitter provides accurate level measurements of liquids, slurries, and solid materials.
It measures the level top down and is therefore unaffected by most fluid property changes, like density and viscosity.
Operating Pressure Full vacuum to 232 psi (Full vacuum to 16 bar)

Operating Temperature -40 to 302°F (-40 to 150°C), -67 to 392°F (-55 to 200°C) for parabolic antenna
Communication Protocol 4-20 mA/HART®, Foundation™ Fieldbus, Modbus®
Safety TÜV tested and WHG approved for overfill prevention
Antenna Type Cone antenna, Rod antenna, Process seal antenna, Parabolic antenna
Operating Frequency Low or high frequency options (6 GHz or 26 GHz)

Rosemount 5401
Rosemount 5401 is a low-frequency non-contacting radar designed for use in tough, challenging turbulence and foam
applications.
Characteristics include:

• Ideal for applications with obstacles, condensation, vapor, dust, and contamination, or where there is a risk
of deposits forming on the antenna
• Condensation-resistant cone or rod antennas

Rosemount 5402
Rosemount 5402 is a high-frequency non-contacting radar designed for outstanding performance in a wide range of
applications and process conditions.

Characteristics include:

• Preferred choice for most applications


• Build-up resistant cone antenna
• A narrow radar beam suitable for mounting on valves, taller nozzles, and smaller openings
• Condensation-resistant process seal antenna
• Rosemount 5402 with 4-in. cone or parabolic antenna available for solids measurements

Rosemount 5408
26 GHz FMCW with unique energy efficient radar chip
Accuracy ± 0.08 in. (± 2 mm)
Measurement Range 131 ft (40 m), 82 ft (25 m) for Rosemount 5408:SIS in Safety mode
Operating Pressure 1450 psi (100 bar)
Operating Temperature -76 to +482 °F (-60 to +250 °C)

Power Supply 12-42.4V dc (12-30V dc in Intrinsically Safe installations)


Communication Protocol 4-20mA HART (2-wire loop-powered)
Point Level Detection
Rosemount™ 2110 Level Switch - Vibrating Fork
It is ideal for simple, fast-fit level applications and basic overfill prevention.
Hygienic certificates expand application capability to include sanitary processes.
Operating Pressure -3.62 to 1450 psi (-0.25 to 100 bar)

Operating Temperature -40 to 302°F / -40 to 150°C

Rosemount™ 2120 Level Switch - Vibrating Fork


Communication Protocol Direct Load, PLC/PNP, Relay, 8/16 mA, NAMUR
Process Media Density Minimum 37.5 lb/ft3 (600 kg/m3)
Viscosity 0.2 to 10000 cP (centiPoise)

Operating Pressure Full vacuum to 1450 psi (Full vacuum to 100 bar)
Operating Temperature -40 to 302 °F (-40 to 150 °C)
Can be operated using the sun or battery as a power source with the 12Vdc option
3-A and EHEDG certificates for hygienic applications. Compliance with FDA and ASME-BPE standards

Rosemount™ 2130 Level Switch - Vibrating Fork


Developed for challenging applications, tough operating conditions and safety critical environments.
Operating Pressure Full vacuum to 1450 psi (Full vacuum to 100 bar)

Operating Temperature -94 to 500°F (-70 to 260°C)


Safety SIL2 IEC 61508 certified

TÜV tested and WHG approved for overfill prevention


Diagnostics Electronic self-checking and condition monitoring

Rosemount™ 2140 Level Detector - Vibrating Fork


The world's first wired HART® vibrating fork level detector for applications including overfill prevention, high and
low level alarms, and pump protection.

Operating Pressure Full vacuum to 1450 psig at 122 °F psi (100 barg at 50 °C)
Operating Temperature -40 to 302 °F (-40 to 150 °C) as standard. -94 to 500 °F (-70 to 260 °C) as option
Certifications/Approvals TBD

Safety IEC 61508 SIL 2 Certified


Diagnostics Continuous electronic self-checking and condition monitoring.
Optional: Smart diagnostics suite: Frequency profiling, power advisory and configurable process alerts

Optional: Functional / partial proof test. Only Rosemount 2140:SIS: Remote partial proof-test
Temperature
Transmitters
Rosemount™ 248 Temperature Transmitter
Input Single sensor capability with universal sensor inputs (RTD, T/C, mV, ohms)
Output Signal 4-20 mA /HART® protocol
Housing DIN B head mount or rail mount
Diagnostics Basic diagnostics including open/short sensor diagnostics

Available in rail or head mount configuration for application flexibility

Rosemount™ 644 Temperature Transmitter


Input Dual and single sensor capability with universal sensor inputs (RTD, T/C, mV, ohms)

Output Signal 4-20 mA /HART® protocol, FOUNDATION™ fieldbus protocol, PROFIBUS® PA protocol
Housing Field mount, DIN A head mount or rail mount

Display/Interface LCD Display or LCD Display with Local Operator Interface (LOI)
Diagnostics Basic diagnostics, Hot Backup™ capability, sensor drift alert, thermocouple degradation, min/max
tracking

Minimum and maximum temperature tracking observes temperature extremes for easy troubleshooting

Rosemount™ 848T Temperature Transmitter


Input Eight independently configurable inputs, including 2- and 3- wire RTDs, thermocouples, mV, 2- and 3- wire
ohm, and 4-20 mA signals
Output Signal FOUNDATION™ Fieldbus protocol
Housing Plastic, aluminum, or stainless steel junction box

Diagnostics Measurement validation

Sensors
Rosemount™ 214C RTD Temperature Sensor
single or dual element resistant temperature detector (RTD) that covers a wide range of temperatures,
from -321 to 1112°F (-196 to 600°C).
Time Constant / Response 10.8 seconds maximum required to reach 50% sensor response when tested in flowing
water according to IEC 60751:2008

Rosemount™ 214C Thermocouple Temperature Sensor


Features resilience and durability in tough process environments.
Covers a wide range of temperatures from -196 to 1200 °C for durability in varying process environments

Rosemount™ 65 RTD Temperature Sensor


Time Constant / Response 9 seconds maximum required to reach 50% sensor response when tested in flowing water
according to IEC 751:1983, Amendments 1 and 2
Industry-standard sensor per IEC 751 with single or dual element design offers reliable and flexible performance
Sensor selections cover a wide range of temperatures from –321 to 1112°F (–196 to 600°C) to meet process demands
Rosemount™ 0085 Pipe Clamp Temperature Sensor
Provide an adaptable surface temperature measurement solution over a wide range of temperatures.
Resistance temperature detector (RTD)

Sensor covers wide range of temperatures -328 to 572 °F (-200 ° to 300 °C) to meet application demands
Non-intrusive design eliminates need for process penetration of fluids with toxic properties for added safety

Rosemount™ 185 Thermocouple Temperature Sensor


Certifications/Approvals Hazardous location, see full specs for complete list of certifications
Sensor selections cover a wide range of temperatures from -40 to 1832°F (-40 to 1000°C) to meet process demands
Available in single element, dual element and isolated configurations with ungrounded junctions for adaptability

Rosemount™ 68Q Sanitary Temperature Sensor


Resistance temperature detector (RTD)
This RTD is designed with a Tri Clamp® sanitary endcap configuration for easy installation and its aseptic process
connection is suitable for clean-in-place (CIP), dead-pocket free, measurement applications.
Withstands -58 to 392 °F (–50 to 200 °C) temperature range for application durability

Rosemount™ 58C Cut-to-Fit Temperature Sensor


Temperature range –50 to 200 °C (–58 to 392 °F)
Stability ±0.035% maximum ice-point resistance shift following 1,000 hours at maximum specified temperature (200
°C)
Industry-standard, platinum resistance temperature detector (RTD) sensor.

Cut-to-fit capability allows sensor to be shortened with a standard tube cutter to meet application specifications

Rosemount™ 1067 Compact Temperature Sensor


Resistance temperature detector (RTD) and thermocouples;
Temperature range -196 to 600°C

Global hazardous location approvals fulfill local requirements

Paine™ 215-01-080 Series, Surface, Temperature Sensor


Platinum, resistance temperature detector (RTD) probe designed for high temperatures;
Temperature Range -20 to 250 °C
Sensor withstands corrosion and oxidation in harsh and extreme environments for durability

Paine™ 225-10-0X0 Series, Digital Temperature Probe


Temperature Range -40 to 302 °F (-40 to 150 °C)
Temperature measurement solution with real-time, digital accuracy and rapid change detection.

Paine™ 215-01-120 Series, Direct Media, Temperature Sensor


Critical temperature measurement solution for high pressure fluids in machinery, engines and process equipment;

Platinum resistance temperature detector (RTD)


Temperature Range -31 to 260 °C

Potrebbero piacerti anche