Sei sulla pagina 1di 4

HER301

THRU
HER308
HIGH EFFICIENCY SILICON RECTIFIER
VOLTAGE RANGE 50 to 1000 Volts CURRENT 3.0 Amperes

FEATURES
* Low power loss,high efficiency
* Low leakage
* Low forward voltage drop
* High current capability
* High speed switching
DO-201AD
* High reliability
* High current surge

MECHANICAL DATA
.052 (1.3 )
* Epoxy: Device has UL flammability classification 94V-O DIA.
1.0 (25.4) .048 (1.2 )
* Case: Molded plastic MIN.

* Lead: MIL-STD-202E method 208C guaranteed


* Mounting position: Any
* Weight: 1.20 grams .375 (9.5)
.335 (8.5)

.220 (5.6 )
DIA.
.197 (5.0 )

1.0 (25.4)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS MIN.

Ratings at 25 o C ambient temperature unless otherwise specified.


Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.

Dimensions in inches and (millimeters)

MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted)


RATINGS SYMBOL HER301 HER302 HER303 HER304 HER305 HER306 HER307 HER308 UNITS
Maximum Recurrent Peak Reverse Voltage VRRM 50 100 200 300 400 600 800 1000 Volts
Maximum RMS Voltage VRMS 35 70 140 210 280 420 560 700 Volts
Maximum DC Blocking Voltage VDC 50 100 200 300 400 600 800 1000 Volts
Maximum Average Forward Rectified Current
at T A = 50 OC IO 3.0 Amps

Peak Forward Surge Current 8.3 ms single half sine-wave I FSM 200 150 Amps
superimposed on rated load (JEDEC method)
RqJL 8.5
Typical Thermal Resistance (Note 1) 0
C/W
RqJA 20
Typical Junction Capacitance (Note 2) CJ 70 50 pF
Operating Temperature Range TJ 150 0
C
Storage Temperature Range T STG -55 to + 150 0
C

ELECTRICAL CHARACTERISTICS (@TA=25 OC unless otherwise noted)


CHARACTERISTICS SYMBOL HER301 HER302 HER303 HER304 HER305 HER306 HER307 HER308 UNITS
Maximum Instantaneous Forward Voltage at 3.0A DC VF 1.0 1.3 1.7 Volts
Maximum Average Reverse Current @T A = 25 o C 5 mA
IR
at Rated DC Blocking Voltage @T A = 125 o C 150 mA
Maximum Reverse Recovery Time (Note 4) trr 50 75 nSec
NOTES : 1. Thermal Resistance : Mounted on PCB. 2007-08
2. Measured at 1 MHz and applied reverse voltage of 4.0 volts.
3. “Fully ROHS compliant”, “100% Sn plating (Pb-free)”.
4. Test Conditions: IF= 0.5A, IR= -1.0A, IRR= -0.25A.
RATING AND CHARACTERISTICS CURVES ( HER301 THRU HER308 )

trr
50 W 10 W +0.5A
NONINDUCTIVE NONINDUCTIVE

(-)
D.U.T
(+) 0
25 Vdc PULSE
GENERATOR
(approx) (NOTE 2) -0.25A
(-)
1 (+)
NON- OSCILLOSCOPE
INDUCTIVE (NOTE 1)

NOTES: 1 Rise Time = 7ns max. Input Impedance =


1 megohm. 22pF.
-1.0A
2. Rise Time = 10ns max. Source Impedance = 1cm
50 ohms.
SET TIME BASE FOR 20/1 ns/cm
FIG.1 TEST CIRCUIT DIAGRAM AND REVERSE RECOVERY TIME CHARACTERISTIC
INSTANTANEOUS REVERSE CURRENT, (uA)

3.0 1000
AVERAGE FORWARD CURRENT, (A)

2.5 TA = 125 OC
100

2.0
TA = 75 OC
10
1.5

TA = 25 OC
1.0 Single Phase 1.0
Half Wave 60Hz
Resistive or
Inductive Load
0.5 0.1
0 25 50 75 100 125 150 175 0 20 40 60 80 100 120 140
AMBIENT TEMPERATURE, (OC) PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)

FIG.2 TYPICAL FORWARD CURRENT FIG.3 TYPICAL REVERSE


DERATING CURVE CHARACTERISTICS
RATING AND CHARACTERISTICS CURVES ( HER301 THRU HER308 )
INSTANTANEOUS FORWARD CURRENT, (A)

20 200
8.3ms Single Half Sine-Wave

PEAK FORWARD SURGE CURRENT, (A)


10 150 (JEDED Method)
TJ = 25 OC 125
100
3.0
HER306~HER308
1.0
50
HER304~HER305
0.3
30
0.1 HER301~HER303
20 HER306~HER308
0.03 Pulse Width=300uS
1% Duty Cycle HER301~HER305
0.01 10
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 1 5 10 50 100
INSTANTANEOUS FORWARD VOLTAGE, (V) NUMBER OF CYCLES AT 60Hz
FIG.4 TYPICAL INSTANTANEOUS FORWARD FIG.5 MAXIMUM NON-REPETITIVE FORWARD
CHARACTERISTICS SURGE CURRENT

200
HER301~HER305 TJ = 25 OC
100
JUNCTION CAPACITANCE, (pF)

60
40
HER306~HER308
20

10
6
4

1
0.1 0.2 0.4 1.0 2 4 10 20 40 100
REVERSE VOLTAGE, (V)
FIG.6 TYPICAL JUNCTION CAPACITANCE
DISCLAIMER NOTICE

Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liabi-
lity for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" paramet-
ers which may be included on RECTRON data sheets and/ or specifications ca-
n and do vary in different applications and actual performance may vary over ti-
me. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.

Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other rela-
ted applications where a failure or malfunction of component or circuitry may di-
rectly or indirectly cause injury or threaten a life without expressed written appr-
oval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rect-
ron Inc and its subsidiaries harmless against all claims, damages and expendit-
ures.

Potrebbero piacerti anche