TK206OBD

GPS+GPRS+OBD

Thank you for purchasing the GPS tracker. This manual shows how to

operate the device smoothly and correctly. Make sure to read this manual

carefully before using this product. Please note that specification and

information are subject to changes without prior notice in this manual. Any
change will be integrated in the latest release. The manufacturer assumes

not to be responsible for any errors or omissions in this document.

1. Technical parameter
1).GSM:850/900/1800/1900 Quad band

2).GPRS: Class12, TCP/IP

3).Working Voltage:9-50V DC

4).Working current:≈22mA (12vDC)

5).Working current:≈12mA (24vDC)

6).GPS locating time:Cold start≈38s(Open sky)

Warm start≈32s

Hot start≈2s(Open sky)

7).GPS Precision:10m(2D RM)

8).Working temperature:-20℃~+70℃
9).Working humidity:20%~80%RH

10).Measurement:71(L)×49(W)×24(H)mm

2. SUMMARY

Working Based on existing GSM/GPRS network and GPS

satellites, this product can locate and monitor any remote

targets by SMS or internet. The most advanced technology

of GPS and A-GPS dual positioning.

3.Device status indicators

3.1Connect DC 9-24V power supply and the red LED will light

continuously.

3.2The green LED glistens when searching the GPS signals. When GPS

works, the LED lights continuously.

3.3The intermediate blue LED (GSM signal state)


GSM signal is normal, blue LED light long bright. No GSM signal, the

blue LED flashes(0.2 sec/2 sec).

GPS LED not fixed, long bright. Positioning flashes(0.2 sec/2 sec);

Power LED: long bright;

4.Installation
Insert the SIM card into the SIM card

Connect the device to the 9-40Vpower supply.(the red LED constant glow)

The SIM card must be with GPRS function and enough deposit. If your SIM card

need input PIN when power on, please cancel it.,It is sim card of 2G GSM
network

5.User Settings

5.1 Set class instruction

Factory default device is not added platform,

if you need to contact the dealer add platform

1) CENTER

Text
Parameter Sample
command

CENTER 710#number# 710#13500135000#

Add 711#number# 711#13800138000#

CENTER D01# D01#

Del D02# D02#


1)Center number can control the oil and power and resume

factory settings

2) Center number can receive the call and text of vibration

alarm and over speeding alarm.

Command 3) SIM must display the income call number to control oil and

Description power.

4) Only one number can be center number.

5) Change center number must resend the command.

6)Add new center number by CETNER,A, and delete by

CENTER,D

Command
Successful Setting:Add admin account 1 OK!
Feedback
2) Authorized number set

Text
Parameter Sample
command

101# number # 1:101#13800138000#


Authorized
102# number # 2:102#12345678912#
Add
103# number # 3:103#12345678912#

D11# D11#
Authorized
D12# D12#
Del
D13# D13#

1) Authorization number for SMS control oil.


Command
2) only three numbers to set the authorization number
3) change the authorization number needs to delete the
Description
previous number

Command
Successful Setting:Add Authorization account 1 OK!
Feedback
3) where

Text
Parameter Sample
command

WHERE 666# 666#

Command
Check the location link of Google map
Description

Command <Datetime:12-07-05 13:21:30>

Feedback http://maps.google.com/maps?q=N22.540885,E113.95265

4) VIBRATION(First to set up the center and authorization, to come true the

vibration alarm)

Text command Parameter Sample


VIBRATION
123#2#alarming way# 1) 123#2#3#
Parameter

Set into
1) V123#2#
vibration alarm V123#2#
2) V123#1#
time

Cancel
456# 456#
vibration alarm

the sensitivity value of the vibration is from 1 to 5 , 1is

Command the most sensitive and o is close. Alarming ways: 1,

Description calling 2, texting, 3 calling and texting.

Must set the center number and receiving number.

Command
set vibration alarm level,OK!
Feedback
5) SPEEDING

Text
Parameter Sample
command

SPEEDING SSA#120#alarming 1)SPEEDING,120,3#

Parameter way# 2)SPEEDING,120#

The speed scope is form 60-220, if the speed is no

Command this cope, the alarm is off.

Descriptio Alarming : 1, calling 2, texting, 3 calling and

n texting.

Must set the center number and receiving number.

Command
Successful Setting:set speeding alarm,OK!
Feedback

ONLINE PLATFORM TRACKING


COMMAND INSTRUCTION TO SET THE ACCES POINT NAME (APN)

Platform real time tracking,if you need use this function ,pls contact

your supplyer about add imei to platform

1) APN(If you need a platform tracking, please set the APN)

Text command Parameter Sample

APN#username#p 1:APN#intenet#123#123#
APN Setting
assword] 2:APN#wap#

APN differs according to the local telecom operators.


Command
For example : APN request password , please refer to
Description
Sample1,and Sample2 for no password.

Command
Successful Setting:SET APN OK!
Feedback
2) Set ip,port of SERVER
Parameter Sample

SERVER
803#SERVER # port# 803#58.61.154.247#7018#
Parameter

view SERVER CIP# CIP#

Change the IP and port when move to a new server


Command
port:10~65535
Description
1 is domain and 0 is IP;

Command
Successful Setting:set IP OK!
Feedback

3)get adress Need to connect Platform )

Text
Parameter Sample
command
WHERE 988# 988#

Command Check the longitude and altitude and other information of

Description the device

Command
Reply with longitude and altitude, speed and IMEL.
Feedback

4) TIMER

Text command Parameter Sample

TIMEER

Parameter 730#uploading interval# 730#20#

setting

Command Time scope : 0 , 10~60 seconds ; 0,no data

Description uploading;
10~60,means time interval ; the default value is 15

seconds!

Command
Successful Setting:SET TIMER OK!
Feedback

5) GMT

Text
Parameter Sample
command

801#location,
GMT 801#E8#
time#

Command The default time zone is Beijing time. If time zone need

Description revised, please operate according to the above command.

Command
Successful Setting:Set time zone ok!
Feedback
6) rebooting

Text
Parameter Sample
command

RESET 930# 930#

Command

Descriptio Reset the device

Command
Successful Setting:Reset system, ok!
Feedback

7) FACTORY set

Text Parameter Sample


command

Parameter 940# 940#

Command Restore the factory setting

Descriptio Only center number can initial this function

n Factory setting will recover to the original setting

Command
Successful Setting:FACTORY OK!
Feedback

8) PARAM

Text
Parameter Sample
command

PARAM 886# 886#

Command The command is to check the settings and the default

Description parameter.
IMEI:351190012535936

APN : cmnet

IP:IP and port


Command
MUP TIMER: moving uploading interval
Feedback
SUP TIMER: static uploading interval

LANG: language(CN/EN)

GMT: time zone (E/W8)

9) STATUS

Text
Parameter Sample
command

STATUS 902# 902#

Command The command is designed for checking the device’s

Description working status.


External power:ON/OFF

GSM Signal:HIGH/MIDDLE/LOW
Command

GPS:FIXED/UNFIXED
Feedback

Vibrate Warning:ON/OFF

Pause:ON/OFF

Note: The GPS tracker must be installed professional personnel)

(SIM card is gsm of 2g network ,if need platform tracking pla

open GPRS function and enough deposit. And no PIN

Must to have GSM single

Note:Indoor and parking no GPS single, metal cover without GPS

signal

Pls take device to outdoor and front towards the sky