Sei sulla pagina 1di 1
aR, force ipa nduies nc. «+1 281 847 2087 on, 190377038 howor@avepips con FUTURE PIPE INDUSTRIES Und Soe of Arte vrlaesipe com/ Short Term Burst Test Report Date: Test: 10/16/09 ‘Snortterm burst pressure (with Fiberglass connection) test report per ASTM D159 & API 15HR Sample ID & description: Pipe: YB-API 10” x 750 psi; pipe number 625 Pin x box L = 30 feet Sample with nipple and end connections: (One end fitted steel xbox end cap, other end fitted with steel x pin end cap. End connections are free. Procedure: Sand bags were fitted at both ends of the test piece but, not touching the tested piece. High pressure pump was fitted to steel end cap along with a calibrated pressure gauge accurate to +/- 50 psi. The pump was started and the pressure increased at a rate of about 500 psi every 30 seconds wih a 15 second pause to check for leaks. Test was terminated when the body of the pipe ruptured, a joint fallure ocourred, or pressure was not sustained due to body weepage. All these failures were indicated by a rapd pressure drop onthe gauge. Results: QL pene Body Weep at 2629 psi QC Department CL DP et AMERICAS | MEA GCC ASIA