Date 9-Sep-19
Time : 8:30
Designed By: Se TH
PILE SET CALCULATION FOR 400 mm x 400 mm RC PILE C1 Checked By : Ir. Se Thiam Hai
Reference Calculation Output
PILE SET CALCULATION FOR 400 mm x 400 mm RC PILE (WORKING LOAD = 515.57 kN AT 30 m
Set Calculation For Hammer Driven Piles Using Modofoed HILLEY's Formula
Based on Table 193, Reinforced Concrete Designer's Handbook - 9th Edition
Efficiency of Blow
= P/w = 120.2 / 5 = 1.5025 = 1.5
Therefore, The Allowable Penetration (mm) Per Last 10 Blows During Pile Setting
s = 10/(n x Fs) = 10 / (0.167397 x 2.5) = 23.9 mm
Title : abc Job Ref: Testing
Date 9-Sep-19
Time : 8:30
Designed By: Se TH
PILE SET CALCULATION FOR 400 mm x 400 mm RC PILE C1 Checked By : Ir. Se Thiam Hai
Reference Calculation Output