R1
1AIR-CONDITIONER
CAUTION!
Follow all safety recommendations and safe shop practices outlined in the front of this manual
or those contained within this section.
Always use tools and equipment that is in good working order.
Use lifting and hoisting equipment capable of safely handling load.
Remember, that ultimately safety is your own personal responsibility.
AIR-CONDITIONER S0605010
Air-Conditioner S0605010
Page 1
TABLE OF CONTENTS
General Description........................................................................................ 3
Refrigerant Circulation.................................................................................... 4
Control Panel.................................................................................................. 6
Control Specifications..................................................................................... 7
Temperature Level Control and Display.......................................................... 8
Air Discharge According to Path Selection..................................................... 9
Air-conditioning System Circuit Diagram...................................................... 12
Troubleshooting ............................................................................................ 14
Refrigerant System Repairs ......................................................................... 17
Refrigerant Safe Handling Procedures ................................................. 17
Repair and Replacement Procedure..................................................... 18
Refrigerant Recovery ............................................................................ 20
Vacuuming Refrigerant System............................................................. 20
Leakage Check ..................................................................................... 21
Refrigerant Charging............................................................................. 22
Inspecting System For Leakage............................................................ 24
S0605010 Air-Conditioner
Page 2
GENERAL DESCRIPTION
HAOA790L
Figure 1
The heater and air-conditioner are combined into one blower unit located in the rear cover of operator's
seat. If necessary, the operator can control inner temperature using the operation panel installed in the
right control stand.
The unit is equipped with an air filtration system
which filters out dirt and dust particles from air
being circulated into the operator’s cab. This
filter (1, Figure 2) should be cleaned out at 1
approximately every 500 hours and replaced
with a new one every 1000 hours.
NOTE:
WARNING!
HAOO790L
All service and inspection of the air
conditioning system should be performed Figure 2
with the ignition switch in the "O" (OFF)
position.
NOTE:
Air-Conditioner S0605010
Page 3
REFRIGERANT CIRCULATION
Figure 1
Reference Reference
Description Description
Number Number
1 Evaporator 5 Compressor
2 Expansion Valve 6 Blower Fan
3 Condenser 7 Receiver Dryer
4 Condenser Fan
S0605010 Air-Conditioner
Page 4
Shading Temperature Refrigerant State
High High Pressure Gas
• Refrigerant (R134a) is compressed to approximately 15.0 kg/sq cm (213.35 psi) within the
compressor.
• The compressed refrigerant flows into the condenser at high temperature (approximately 80°C
(176°F)).
• The refrigerant in the condenser is cooled to approximately 60° by the condenser fan. At this
time the refrigerant changes from the gas to the liquid state, even though the temperature has
only been reduced 20°C (68°F). (From 80° - 60°C (176° - 140°F)).
• The refrigerant in its liquid form is injected into the evaporator through the expansion valve. At
this time the pressure is reduced by approximately 2.0 kg/sq cm (28.45 psi) and the
temperature is also reduced. As a result, the refrigerant absorbs the heat from the air
surrounding the evaporator creating a cooling effect and changes from the gas to the liquid
state.
• The refrigerant once again flows into the compressor in the gaseous state and the process is
repeated.
WARNING!
Refrigerant gas is pressurized and sealed in the air conditioning system. Special
precautions are required for the proper recharging or release of refrigerant. Release of
refrigerant into the atmosphere is strictly regulated by law. Make sure that you are in
compliance with all mandated federal, state and municipality requirements, before starting
any service or repair of the air conditioner. Refrigerant gas used in the system must meet or
exceed specifications for R134a refrigerant, or any subsequently issued environmentally-
mandated standard.
Air-Conditioner S0605010
Page 5
CONTROL PANEL
HDA6047L
Figure 2
DISPLAY
TEMPERATURE
SENSOR
LOW SPEED RELAY
INTAKE RECYCLE/FRESH
ACTUATOR AIR CONTROL
HDA6048L
Figure 3
S0605010 Air-Conditioner
Page 6
CONTROL SPECIFICATIONS
HDA6049L
Figure 4
HDA6050L
Figure 5
Figure 6
Air-Conditioner S0605010
Page 7
TEMPERATURE LEVEL CONTROL AND DISPLAY
Position
Step LED 1 LED 2 LED 3 LED 4 LED 5 LED 6 LED 7 Sensor Remark
Voltage
0 Green Green Green Green Green Green Green 4.50 V ± 0.2 MAX. COOL
1 Green Green Green Green Green Green Green 4.33 V ± 0.2
2 Green Green Green Green Green Green Green 4.15 V ± 0.2
3 Red Green Green Green Green Green Green 3.98 V ± 0.2
4 Red Green Green Green Green Green Green 3.80 V ± 0.2
5 Red Green Green Green Green Green Green 3.63 V ± 0.2
6 Red Red Green Green Green Green Green 3.46 V ± 0.2
7 Red Red Green Green Green Green Green 3.28 V ± 0.2
8 Red Red Green Green Green Green Green 3.11 V ± 0.2
9 Red Red Red Green Green Green Green 2.93 V ± 0.2
10 Red Red Red Green Green Green Green 2.76 V ± 0.2
11 Red Red Red Green Green Green Green 2.59 V ± 0.2
12 Red Red Red Red Green Green Green 2.41 V ± 0.2
13 Red Red Red Red Green Green Green 2.24 V ± 0.2
14 Red Red Red Red Green Green Green 2.07 V ± 0.2
15 Red Red Red Red Red Green Green 1.89 V ± 0.2
16 Red Red Red Red Red Green Green 1.72 V ± 0.2
17 Red Red Red Red Red Green Green 1.54 V ± 0.2
18 Red Red Red Red Red Red Green 1.37 V ± 0.2
19 Red Red Red Red Red Red Green 1.20 V ± 0.2
20 Red Red Red Red Red Red Green 1.02 V ± 0.2
21 Red Red Red Red Red Red Red 0.85 V ± 0.2
22 Red Red Red Red Red Red Red 0.67 V ± 0.2
23 Red Red Red Red Red Red Red 0.50 V ± 0.2 MAX. HOT
S0605010 Air-Conditioner
Page 8
AIR DISCHARGE ACCORDING TO PATH SELECTION
Vent
Figure 7
Reference Reference
Description Description
Number Number
1 Select Switch 4 Heater Core
2 Side Vent 5 Evaporator Core
3 Rear Vent 6 Blower Motor
Air-Conditioner S0605010
Page 9
Foot
Figure 8
Reference Reference
Description Description
Number Number
1 Select Switch 2 Foot Vent
S0605010 Air-Conditioner
Page 10
Defroster
Figure 9
Reference Reference
Description Description
Number Number
1 Select Switch 2 Defroster Vent
Air-Conditioner S0605010
Page 11
AIR-CONDITIONING SYSTEM CIRCUIT DIAGRAM
Figure 10
S0605010 Air-Conditioner
Page 12
Reference Reference
Description Description
Number Number
1 Battery 15 Compressor
2 Battery Relay 16 A/C Control Panel
3 Fusible Link 17 A/C Unit
4 Circuit Breaker 17-1 Blower Motor
5 Fuse 17-2 Resister
6 Fuse 17-3 High Speed Relay
7 Fuse 17-4 Mid Speed Relay
8 Lamp Switch 17-5 Low Speed Relay
9 Foot / Defrost Control 17-6 Recirculate / Fresh Air
Actuator Control Actuator
10 Compressor Relay 17-7 Vent Actuator
11 Condenser Fan Relay 17-8 Temperature Control
12 Condenser Fan Motor Actuator
13 Receiver Dryer (Low / High 17-9 Temperature Sensor
Pressure Cut Off Switch) (Evaporator)
14 Diode
Air-Conditioner S0605010
Page 13
TROUBLESHOOTING
Refrigerant Pressure Check
Figure 11
S0605010 Air-Conditioner
Page 14
High Pressure: Approximately 20 - 25 kg/cm2 (284.47 - 355.58 psi)
3
Low Pressure: Approximately 2.5 - 3.5 kg/cm2 (35.56 - 49.78 psi)
Possible Cause: Air in system.
1. Recover any remaining refrigerant.
2. Vacuum out system.
3. Recharge system.
NOTE:
Air-Conditioner S0605010
Page 15
High Pressure: Over 7.0 - 11.0 kg/cm2 (100 - 156 psi)
7
Low Pressure: 4.0 - 6.0 kg/cm2 (57 - 85 psi)
Possible Cause: Low refrigerant pressure due to poor compressor compression
Inspect and replace compressor if necessary.
S0605010 Air-Conditioner
Page 16
REFRIGERANT SYSTEM REPAIRS
WARNING!
Always wear protective glasses and gloves when handling refrigerant. If refrigerant comes in
contact with the skin or eyes, immediately flush with clean, running water and consult a
physician.
Select a clean and well ventilated area to work.
The refrigerant container is under high pressure and should be stored below 40°C (104°F). Be
careful not to drop the container from a high location
The contents are under high pressure and should not be used with compressed air or near an
open flame.
Figure 12
The following procedures should be observed for safe handling of refrigerant during vacuum and charging
process.
1. Use an approved recovery / charging device which can safely perform vacuum and charge work
simultaneously.
2. The new refrigerant has improved cooling characteristics than the old type and care should be used
not to overcharge the system.
3. Do not over tighten connections when working on refrigerant system.
4. The new refrigerant system standards require new tools, equipment and parts. DO NOT attempt to
use equipment use in servicing the old refrigerant system.
Air-Conditioner S0605010
Page 17
5. The new refrigerant oil (PAG type) has a high moisture absorption characteristic. When the
refrigerant system vacuum seal has been broken, immediately plug up all openings to prevent
moisture from entering into the system.
6. When joining unions which use O-ring seals, lightly coat O-rings with refrigerant oil. Be careful not to
drip oil on the threads of the nut.
7. Be certain the O-rings are seated properly on the refrigerant line lip. Always use new O-rings when
reassembling parts. Do not reuse old O-rings.
8. Use a vacuum pump to evacuate refrigerant system of air.
9. When charging the refrigerant system with the engine running, do not open the high pressure valve
on the manifold gauge as the reverse flow of high pressure refrigerant will rupture the hose.
10. When releasing the high pressure hose after completing the charging process, quickly disconnect the
hose to minimize refrigerant released to the air.
S0605010 Air-Conditioner
Page 18
INSTALL REPAIR TOOL
RECOVER REFRIGERANT
RUN SYSTEM
Air-Conditioner S0605010
Page 19
REFRIGERANT RECOVERY
Reference
Description 2 3
Number
1 To Compressor 1 4
2 Low Pressure Side
3 High Pressure Side
4 From Receiver
5 Refrigerant Recovery Tank
2. Open the high pressure valve slowly to release the refrigerant to the recovery unit.
NOTE:
3. When the manifold gauge dial falls below 3.5 kg/cm2 (50 psi), slowly open the low pressure valve.
4. Open both the high and low pressure valves slowly until the manifold gauge dials indicates 0 kg/cm2
(0 psi).
Reference 2 3
Description
Number 1 4
1 To Compressor
2 Low Pressure Side
3 High Pressure Side
4 From Receiver
5 Vacuum Pump
1. Vacuuming Procedure 5
HDA6068L
NOTE: Figure 15
A. Attach the manifold gauges and vacuum pump to the refrigerant system as shown.
B. Turn on the vacuum pump and open both valves.
C. When the low pressure gauge shows approximately 710 mmHg, close both valves and turn off
vacuum pump.
S0605010 Air-Conditioner
Page 20
2. Check system for vacuum leak.
Allow system to sit for 10 minutes and
check whether the system is holding the
pressure. If the pressure has dropped, it
must be repaired before proceeding to the
next step.
3. Vacuuming Procedure
If the system is holding the pressure and it
has not changed for 10 minutes, vacuum
out the system for an additional 20
minutes. HDA6069L
Figure 16
A. Turn on the vacuum pump and slowly
open both valves.
B. Allow vacuum pump to run for additional 20 minutes until the low pressure gauge dial reads
approximately 750 mmHg.
C. Close both valves and stop the vacuum pump.
4. Installation Of Refrigerant Container
Reference 1
Description
Number
1 Handle
2 Hose Connection
3 Mounting Disk 2
LEAKAGE CHECK
NOTE:
1. After attaching the manifold gauge, open the high side valve.
2. Charge system until the low side gauge dial indicates a pressure of 1 kg/cm2 (14.22 psi) and close
the high side valve.
Air-Conditioner S0605010
Page 21
3. Using a refrigerant leak detector or soapy
water check each joint for leakage.
1
Reference
Description
Number
Refrigerant Leak
1
Detection Device
WARNING!
For accurate refrigerant leak
detection, perform leak detection
procedure in a well ventilated area.
REFRIGERANT CHARGING
1. Perform the vacuuming procedure, vacuum holding and leaking tests as described in the proceeding
headings.
NOTE:
Reference
Description 2 3
Number
1 To Compressor 1 4
2 Low Pressure Side
3 High Pressure Side
4 From Receiver
5 Refrigerant Supply
Container
S0605010 Air-Conditioner
Page 22
Engine Speed: 1,300 - 1,500 RPM
WARNING!
When charging refrigerant system with the engine running;
• Always keep refrigerant supply container in the upright position.
• Never open the high side pressure valve.
4. Open the manifold gauge low side valve and charge system to standard capacity.
NOTE:
WARNING!
• When outside temperature is low, warm the refrigerant supply container with
warm water not exceeding 40°C (104°F). Do not allow water to come in contact
with the charging adapter valve handle.
• When outside temperature is high, cool off refrigerant supply container and
condenser to aid the refrigerant charging process.
Air-Conditioner S0605010
Page 23
INSPECTING SYSTEM FOR LEAKAGE
After completing charging procedures, clean all
joints and connections with a clean dry cloth.
Using a refrigerant leak detecting device or
soapy water, inspect system for leaks starting 2
from the high pressure side. 1
NOTE:
4
HDA6073L
Figure 20
Reference
Description
Number
1 Pressure
2 High Pressure
3 Low Pressure
4 Compressor Stop
Inspection Procedure
1. High Pressure Side
Compressor outlet condenser inlet receiver dryer inlet air-conditioner unit inlet
2. Low pressure side
Compressor inlet air-conditioner unit outlet
3. Compressor
Compressor shaft area, bolt hole area and magnetic clutch area.
4. Receiver dryer
Pressure switch and plug area.
5. Connection valve area
Inspect all valve areas.
Verify all valves are capped to prevent leaking.
Check for foreign matter inside of valve cap.
6. Interior of air-conditioning unit.
After stopping engine, insert detector probe into drain hose. (Leave inserted for 10 seconds
minimum.)
NOTE:
S0605010 Air-Conditioner
Page 24