Sei sulla pagina 1di 9

C-SERIES Configurable

Compression Packages
Get the Performance You Want In Every Package
C-SERIES Configurable Compression Packages
Natural gas producers must adapt quickly to changes in Exterran’s C-Series Configurable Compression Packages
the market, product pricing, and diverse locations for the provide the right solution for your immediate compression
production, processing and consumption of natural gas.
Efficient, reliable and flexible compression solutions that
needs. Designed to Exterran’s specifications, you control
the configurability, adding options needed to fit your unique
What Does “Configurable” Mean?
are designed, constructed and installed in a short time production requirements. With C-Series, Exterran gives you Configurable means that you’ll THE NEW C-SERIES OFFERS: SPEED YOUR PRODUCTION TO MARKET.
frame are key to the economics of producing, gathering, speed, confidence and flexibility. We’re ready to be your source have access to complete base-model Engineered to empower, the Exterran
• Two Driver Options:
processing and marketing natural gas. for proven, cost-effective and timely compression solutions. compressor packages which have been C-Series Compression Packages
fully engineered and designed, including > Cat 3516 Lean Burn
give you the configuration flexibility to
all critical studies. > Waukesha 7044 Rich Burn
tailor your operations, and get revenue
More than 60 of the industry’s most • 13 Base Models in 1, 2, flowing faster.
requested options are also completely and 3-Stage Configurations
And if you need compression even
designed and engineered to seamlessly • 10-14 Week Delivery
Table Of Contents integrate with the base-models.
• Proposals and Production
sooner, ask your sales rep about our
ready inventory of pre-configured units
Using an online build it tool, customers Drawings in 2-3 Days available for immediate delivery. Visit
can choose the base-model that best exterran.com/c-series to learn more.
fits their application. Plus add any of
• 60+ Pre-engineered Options and
C-Series Configurable Compression . . . . . . . . . . . . 1 1000+ Configurations
the available options to be included in
the configured package and submit. • Designed with the Highest
Quality Components
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Once an order is submitted, the data
from the selection tool is entered into • Over 60+ Years of Field
Exterran’s Oracle and AutoCAD systems Proven Experience
Key Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 to automatically generate drawings
and bills of material.
The ability to “configure” an Exterran
C-Series 3516 Compression Package . . . . . . . 4 – 5 C-Series package eliminates virtually all
with Caterpillar 3516 lean-burn engine of the up-front engineering costs and
lead time from the package sale.
Imagine this robust, new unit on
C-Series 7044 Compression Package . . . . . . . . 6 – 7
your site, ready to get to work in just
with Waukesha 7044 rich-burn engine 10 - 14 weeks!

Standard and Optional Equipment . . . . . . . . . 8 – 13

Advanced Emissions Control System . . . . . . . . . . . 8

Programmable Logic Control Panel . . . . . . . . . . . . . 9

2% Sour Gas Trim . . . . . . . . . . . . . . . . . . . . . . . . 12

Overall Dimensions . . . . . . . . . . . . . . . . . . . . . Back

C-SERIES 3516 Compression Package

Exterran.com 1
C-SERIES Configurable Compression Packages C-SERIES Configurable Compression Packages
OVERVIEW KEY BENEFITS INCLUDE: SPEED • CONFIDENCE • FLEXIBILITY
Exterran C-Series Configurable Gas Both product families are available with FASTER TO GAS REVENUE • Exterran has built thousands of FLEXIBILITY AND SAVINGS
Compression Packages are pre-engineered an extensive list of pre-engineered options GET STARTED NOW units and solved challenges for every •D
 rawing from an extensive list of
and assembled with high-quality such as upsized coolers, PLC panels • Industry-leading deliveries allow application, so you can be highly pre-engineered options, there are
you to get your revenue stream confident that your unit is reliable thousands of ways to customize units
components and a wide range of options and automatic valves.
moving without compromising quality, and fit for purpose. to meet your application requirements.
– allowing for exceptional configuration STANDARD SAFETY FEATURES: performance or configurability. • Field-proven engineering ensures
flexibility and high performance along with • Compact skid designs and
Standard safety features include automatic consistent quality, predictable transportation-considerate packaging
rapid delivery and startup. Two product • Ready inventory of preconfigured
shutdown controls and checker-plated, units usually available for immediate performance, simple operation practices reduce permitting
families are currently available – a 1380 and easy maintenance.
skid-resistant work surfaces. Safety is delivery. requirements and associated
horsepower Caterpillar 3516B lean-burn • Your unit is based on that same trucking costs.
enhanced because all local instrument • Standard drawings available with
engine coupled to an Ariel JGT4 compressor engineering expertise and customers
vents are collected, manifolded and routed proposal. Final production drawings •E
 xterran can install, commission
as well as a 1680 horsepower Waukesha to connections at the skid edge. Our can be generated within 2-3 days of regularly and consistently achieve and service your units to facilitate
L7044GSI rich-burn engine paired with project award to expedite your planning 99+% run-time with C-Series. your startup and unburden your
design facilitates air emissions compliance
an Ariel JGK4 compressor. as well as lower your contract, budget • Engineering and operations experts maintenance operations.
with catalyst housings and exhaust
and schedule risks. are available to assist with any
These combinations are packaged on a sampling ports. Selectable safety options
• Simple assembly and commissioning configuration decisions and/or
heavy-duty steel skid suitable for mounting include exhaust insulation, caged ladders, technical support.
allows you to bring your operation
on a compacted gravel pad, piles or an OSHA-compliant work platforms, and
online quickly.
engineered concrete foundation. trim to handle up to 2% H2S mol.
• From purchasing to delivery to
process gas.
startup, substantial time is saved
which can be directed to other
aspects of your project.

COMPLETE CONFIDENCE
• Exterran’s 60+ years of experience
and unsurpassed expertise as the
global compression leader assures
you are getting high-performing
packages.

C-SERIES 7044 Compression Package

2 Exterran.com 3
C-SERIES 3516 Compression Package
As an X-PRESS SHIPTM product, the C-Series 3516 can be fully Two, 2 inch NPT emissions test ports
configured by the customer and typically delivered in 10 weeks. provided in exhaust silencer/catalytic
converter outlet piping

a
2-002 is convertible as a one or two stage model
Standard Specifications b
A ll cylinders are Ariel ET-class, except for the first 25-30 dB noise reduction with an EMIT
Number Stage Bore Diameter (inches) Performance Ranges
c stage of model 2-002, which is Ariel T-class critical grade silencer and catalyst housing
of Stages Model First Stage Second Stage Third Stage Suction psig Discharge psig Flow MMscfd
• Performance based on double acting cases only
6.375 - -
• Performance assumes sweet gas with specific
1 001 6.000 - - 200 - 600 800 - 1200 8.6 - 43.7
gravity of 0.65
- - -
• The performance ranges shown are specifically
Two Type-K thermocouples for monitoring
- 6.375 - for the cylinder bore diameters that are bolded catalytic converter inlet and outlet temperature
2 001 9.750 6.000 - 50 - 200 600 - 1200 4.4 - 17.1 and on the same row to the left
9.250 - -
- 6.375 - 200 - 325 500 - 650 20 - 28.7 single stage
a
2 002 b
9.625 6.000 - Catalyst and surge-tank service/work platform
b
9.125 - - 100 - 250 1000 - 1200 6.3 - 14.7 two stage integrated with cooler structure (Optional)
- - 6.375
3 001 17.250 11.500 6.000 5 - 50 600 - 1200 3.3 - 7.5
16.750 11.000 -
- - 6.375 Eight , ¾ inch NPT connections enable local
3 002 15.750 11.500 6.000 10 - 50 800 - 1200 3.7 - 7.0 coolant temperature monitoring/management
15.250 11.000 -
- - 6.375 Isolation valves for coolant conservation during
3 003 15.750 9.750 6.000 10 - 40 800 - 1200 3.4 - 6.5 engine service
15.250 9.250 -
- - 6.375
3 004 13.500 9.750 6.000 20 - 60 800 - 1300 4.2 - 7.8
Caged, galvanized ladder to cooler platform
13.000 9.250 - (Optional)

- - - - = ‘3516T4-3-002-15.750-11.500-6.000’ Caterpillar 3516B engine


Stages Model First Second Third (product code example)

Upgraded engine exhaust insulation from


½ inch NPT pressure connections on pulsation Caterpillar included as standard content
bottles enables collection of pulsation data
for future analysis. One, ¾ inch temperature OSHA engine work platforms with handrails
connections on all scrubbers and ladder. One platform on each side of engine
(Optional)
Ariel JGT4 Compressor
Combo Hotstart system for engine oil/water
Pulsation study pre-performed on all base (Optional)
model configurations
Cable and tray electrical system approved for
Engine & compressor oil level regulators use in NEC Class I, Division 2 hazardous
provided with inlet/outlet fire safe valves area classifications
Local instrument-gas vents and sources of
Murphy Centurion control panel fugitive emissions collected/manifolded and
routed to a single skid-edge connection
Hotstart system for compressor oil (Optional)
Weld pad on all scrubbers for future level
One, 2 inch NPT ball valve and associated gauge supports, if needed
½ inch minimum wall thickness for all scrubbers
threaded piping for future fuel meter installation
and bottles for mechanical strength
Basket-style inlet suction screen with
removable spool-piece to enable screen Pressure relief valve vents manifolded into a
removal (Optional) common header and run to skid edge (Optional)

Our C-Series 3516 units are designed to be


set on an engineered gravel pad or concrete
foundation. 12 foot wide skid includes anchor
bolt holes and jacking bolts Note: Colors shown on the renderings are for clarification purposes. The actual units are painted a single color.

4 Exterran.com 5
C-SERIES 7044 Compression Package
Tough field gas applications call for a tough, rich-burn solution.
Two, 2 inch NPT emissions test ports
Now that solution is configurable. provided in exhaust silencer/catalytic
converter outlet piping

• Performance based on double acting cases only


Standard Specifications • Performance assumes sweet gas with specific Two Type-K thermocouples for monitoring
Number Stage Bore Diameter (inches) c
Performance Ranges gravity of 0.65 catalytic converter inlet and outlet temperature
of Stages Model First Stage Second Stage Third Stage Suction psig Discharge psig Flow MMscfd • The performance ranges shown are specifically
- - - for the cylinder bore diameters that are bolded
and on the same row to the left
1 001 6.250 - - 300-600 800-1200 13.6-51.7 35-40 dB noise reduction with an EMIT
5.875 - - hospital grade silencer and catalyst housing
9.625 - -
2 001 9.125 6.250 - 150-400 600-1200 10.9-32.1
- 5.875 - Catalyst and surge-tank service/work platform
11.000 - -
integrated with cooler structure (Optional)
2 002 10.500 6.250 - 100-200 600-1200 8.7-25
- 5.875 -
- - 7.250
3 001 17.875 11.000 6.750 10-30 600-1200 4.46-7.67
17.375 10.500 -
- - 7.250
3 002 15.875 11.000 6.750 20-50 600-1200 5.49-10.59 Cooler-mounted 55-gallon oil day tank (Optional)
15.375 10.500 -
- 11.000 7.250
Cooler fan deck shipping legs (Optional)
3 003 14.125 10.500 6.750 25-70 600-1200 5.4-12.01
13.625 - -
Caged, galvanized ladder to cooler platform
- - - - = ‘7044K4-3-002-15.875-11.000-6.750’ (Optional)
Stages Model First Second Third (product code example)

Waukesha L7044GSI engine

Isolation valves for coolant conservation during


½ inch NPT pressure connections on pulsation engine service
bottles enables collection of pulsation data
for future analysis. One, ¾ inch temperature Eight , ¾ inch NPT connections enable local
connections on all scrubbers coolant temperature monitoring/management

Ariel JGK4 Compressor


OSHA engine work platforms with handrails
and stairs. One platform on each side of engine
Pulsation study pre-performed on all base
(Optional)
model configurations

Engine & compressor oil level regulators Cable and tray electrical system approved for
provided with inlet/outlet fire safe valves use in NEC Class I, Division 2 hazardous
area classifications
Inlet pressure relief valve (Optional) Local instrument-gas vents and sources of
fugitive emissions collected/manifolded and
Basket-style inlet suction screen with routed to a single skid-edge connection
removable spool-piece to enable screen
removal (Optional) Weld pad on all scrubbers for future level
gauge supports, if needed
Off-skid panel mounting available ½ inch minimum wall thickness for all scrubbers
(Optional) and bottles for mechanical strength

Skid drains manifolded to a single


customer connection (Optional)

Note: Colors shown on the renderings are for


Our C-Series 7044 units are designed to be set on an
clarification purposes. The actual units are
engineered gravel pad or concrete foundation. 14 foot
painted a single color.
wide skid includes anchor bolt holes and jacking bolts

6 Exterran.com 7
C-SERIES Configurable Compression Packages • Included with base model ∘ When finished packages are available, these options are included

Standard and Optional Equipment Driver


• Included with base model ∘ When finished packages are available, these options are included Name Item Description Comments
Catalytic • Not included in base package

3516 Specific
Compressor Frame & Cylinders Converter
Elements B23 ∘ (2) DCL catalyst elements and (1) DCL blank element included
Name Item Description
B27 • EMIT Critical Grade (25-30 dBA) catalytic converter/silencer
Variable Volume A01 • Manual head-end VVCP’s included on 1st-stage cylinders only Silencer
Clearance Pockets B28 ∘ EMIT Hospital Grade (35-40 dBA) catalytic converter/silencer
(VVCP’s) A02 ∘ Manual head-end VVCP’s included on 1st-stage, 2nd-stage, and 3rd-stage (if applicable) cylinders
7044 Start B24 •∘ 7044 - Low-pressure (90 PSIG) start gas pressure
A03 •∘ Ariel standard manual priming pump Gas Pressure B22 7044 - High-pressure (150 PSIG) start gas pressure

7044 Specific
Pneumatic-diaphragm compressor pre-lube pump with block valves, check valve
A04 • Not included in base package
and strainer
Prelube
Pump Electric-motor (2HP, 3PH, 60HZ, 480V) driven compressor pre-lube pump with block Emissions B21 Waukesha emPact emissions control system (0.5 g/bhp-hr NOx)
A05 B01 is not available
valves, check valve and strainer. Motor starter provided by customer Controls
B26 Waukesha emPact emissions control system (0.15 g/bhp-hr NOx) with these options
Systems ∘
Electric-motor (2HP, 3PH, 50HZ, 400V) driven compressor pre-lube pump with block
A11 Only one selection
valves, check valve and strainer. Motor starter provided by customer B29 EMIT ETS AFRC Advanced emissions control system
can be made
•∘ Not included in base package •∘ Not included in base package
Catalytic Converter
Hotstart system for compressor oil only, with required valves and strainer DPI B01 Catalytic converter DPI included and tubed low on cooler face for easy viewing and access
Oil Circulating A06
Heater Pump motor is 3HP, 3PH, 60HZ, 2.5KW, 480V
Hotstart system for compressor oil only, with required valves and strainer Catalytic Converter B02 • Catalytic converter test ports locally located on exhaust system above cooler
A12 Test Ports
Pump motor is 3HP, 3PH, 50HZ, 2.5KW, 400V B03 ∘ Catalytic converter test ports tubed low on cooler face for easy access. Includes two half-inch ball valves
•∘ Not included in base package
Lube-Oil Meter Engine Exhaust •∘ Not included in base package
A07 Kenco model 1618 low-flow analog compressor lube-oil meter Insulation B04 Blanket insulation of engine exhaust system including silencer/converter
•∘ Not included. Off-skid oil supply by customer
Fuel Filter Level B05 •∘ Manual drain only on fuel filter
Oil Day Tanks A08 Cooler-mounted Kenco 55-gallon oil day-tank Instrumentation B06 Fuel filter to include level controller, auto dump valve, level gauge, and high-level shut-down
A09 Kenco 55-gallon day-tank and stand (shipped loose for customer installation) B08 •∘ Separate 2 inch fuel & 2 inch start gas connections at skid-edge
Start Gas
Blowcases for •∘ Not included in base package Inlet Piping B09 Fuel and start inlets combined as a single 2 inch connection at skid-edge
Distance Piece &
Packing Drains A10 Jatco Model JATC-J5000CX blowcases. Shipped loose for customer off-skid installation • Not included in base package
Start Gas Inlet PSV
B10 ∘ 1-½ inch x 2 inch NPT start-gas inlet PSV with outlet piping into starter vent piping header
Advanced Emissions Control Systems B11 •∘ Starter exhaust locally piped to safe elevation above top of cooler c/w rain cap
Starter
(Options B21, B26 & B29) Vent Piping B12 Starter exhaust run to its own 3 inch -150# skid-edge connection
When configuring a C-Series package with the L7044GSI engine, •∘ Not included in base package
customers also have the option of including an advanced Lube Oil Meter
B13 Kenco model 1618 low-flow analog engine lube-oil meter
emissions control system. Comprised of a 3-way catalyst, air/
fuel ratio control and a color display panel/interface, an advanced •∘ Not included in base package
emissions control system can simplify operation and keep your Combo Hotstart system for engine oil/water, with required valves and strainer. 480V, 3PH, 60HZ – coolant heater:
Oil Circulating B14
emissions in compliance. Heater 18KW, 1HP pump motor; oil heater: 6KW, 1HP pump motor
Combo Hotstart system for engine oil/water, with required valves and strainer. 400V, 3PH, 50HZ – coolant heater:
B25
18KW, 1HP pump motor; oil heater: 6KW, 1HP pump motor
Connections for temperature indicators and thermocouples to be provided in engine jacket
B15 •∘
water (EJW) and auxiliary water (AW) piping, to and from engine to cooler
Water
While default settings are programmed by the factory, users Only one selection
Temperature B16 Temperature indicators to be provided in EJW and AW piping, to and from engine to cooler can be made
have the ability to adjust to richer or leaner through system Measurement
Temperature indicators and thermocouples to be provided in EJW and AW piping, to and
B17
display panel interface, helping to maintain compliance as the from engine and cooler
engine ages. Optional systems that are currently available are Not included in base package
Waukesha’s emPact system and the “ETS AFRC Advanced” Engine Work Only one selection
B18 ∘ OSHA engine work platforms with handrails and ladder (one platform on each side of engine)
system from EMIT Technologies. Platforms can be made
B19 OSHA engine work platforms with handrails and stairs (one platform on each side of engine)

8 Exterran.com 9
• Included with base model ∘ When finished packages are available, these options are included • Included with base model ∘ When finished packages are available, these options are included

Air Cooler Controls, Instrumentation, & Wiring


Name Item Description Comments Name Item Description Comments
Air-X-Changers 144EH, Exterran standard dimensions and nozzles, D01 •∘ Murphy Centurion
C01 Not selectable along with automatic bypass
sized for customer site conditions
D02 Altronic DE-3000 in lieu of standard Murphy Centurion valve (I03) or automatic blowdown valve (I05)
Air-X-Changers 144EH, Exterran-standard dimensions and nozzles. Control Panel
3516 Specific

C19 Flexible operating conditions (between 110°F ambient at 500 feet and 100°F Make & Model D03 Murphy Centurion Plus in lieu of standard Murphy Centurion
ambient at 7,000 feet) Either C01, C19,
Cooler C02 or C03 Exterran standard Allen-Bradley CompactLogix PLC panel including Murphy PXT transmitters in lieu of standard
Model Air-X-Changers Compact 156EH, Exterran-standard dimensions and nozzles. D11
must be selected Murphy Centurion
C02 ∘ Flexible operating conditions (between 110°F ambient at 500 feet and 100°F
ambient at 7,000 feet) D04 •∘ Panel mounted on skid
Air-X-Changers Compact 156EH, Exterran standard dimensions and nozzles, Control Panel Off-skid control panel with sufficient umbilical length to allow location up to 10 feet from Only one selection
C03 D05
sized for customer site conditions Location compressor end of skid can be made
Air-X-Changers 156EH, Exterran standard dimensions and nozzles, sized for customer Off-skid control panel with sufficient umbilical length to allow location up to 20 feet from
C16 D06
site conditions compressor end of skid
7044 Specific

Air-X-Changers 156EH, Exterran-standard dimensions and nozzles. Flexible operating Either C16 or
Cooler D07 •∘ Regulated gas supplied from downstream of fuel gas filter
Model C17 ∘ C17 or C18 Instrument
conditions (between 110°F ambient at 500 feet and 100°F ambient at 7,000 feet) must be selected Gas/Air Supply D08 1 inch NPT galvanized instrument air header with skid-edge ball valve, regulator PI and root valves
Air-X-Changers 168EH, Exterran-standard dimensions and nozzles, sized for customer
C18
site conditions D09 •∘ Tube fittings are clear-zinc coated, carbon steel
C04 Moore-10K-Series 8-blade cooler fan Tube Fittings
• D10 Tube fittings are 316 stainless steel
Fan Style
C05 ∘ Moore-CL10K-Series 10-blade low-noise cooler fan

• Not included in base package


Service/Work Included when Exterran Standard Programmable Logic Control (PLC) Panel (Option D11)
Platform selecting the
C06 ∘ Catalyst and surge-tank service/work platform integrated with cooler structure Fleet/Flex Coolers
(C02) or (C17) Along with the Murphy Centurion Plus and the Altronic DE-3000, Exterran’s
• Not included in base package configurable PLC is now available as an option in place of the standard Murphy
Ladder C07 ∘ Uncaged, galvanized ladder to cooler platform Centurion control panel. This offering consists of an Allen Bradley CompactLogix
PLC housed in a painted NEMA 4 enclosure. Following the philosophy of the
C08 Caged, galvanized ladder to cooler platform
C-Series product family, the new PLC has been completely pre-engineered
•∘ Not included in base package and programmed to fit within the quick-delivery lead time of the C-Series
Hail Guard
C09 Expanded-mesh hail guard on top of cooler packages and to interact with either the Caterpillar ADEM III or
Waukesha ESM.
•∘ Not included in base package
Bug Screen Process valve sequencing and functionality includes:
C10 Removable mesh bug screens over cooler intake
no valve, manual valve, or automated spring return
•∘ Not included in base package valve selection. All alarms and shutdowns (class
Shipping Legs and function) may be configured on the panel’s
C11 Cooler fan-deck shipping legs (allows cooler to lay on truck for shipping into height-restricted areas)
HMI screen.
C12 •∘ One set of manual louvers across gas-sections to control gas discharge temperature
One set of automatic louvers across gas sections to control gas discharge temperature Only one selection
Louvers C13
(includes Kimray T12 controller and Garzo actuator) can be made
Automatic louvers on each gas section to control gas discharge temperatures
C14
(includes Kimray T12 controllers and Garzo actuators)
• Not included in base package
Corrosion
Allowance C15 ∘ 1/16 inch corrosion allowance on the gas headers

10 Exterran.com 11
• Included with base model ∘ When finished packages are available, these options are included • Included with base model ∘ When finished packages are available, these options are included

Process Vessels (General) Process Gas Piping


Name Item Description Comments Name Item Description Comments

E01 •∘ RT-2 radiographic testing on process vessels Non-Destructive H01 •∘ Per Code ASME B31.3
Non-Destructive Only one selection Examination (NDE) H02 100% Radiography/UT of welds on process piping
E02 RT-1 radiographic testing on ASME coded vessels
Examination (NDE) can be made
H03 •∘ Tested at 1.5 *MAWP for 1/2 hour
E03 100% radiographic testing on ASME coded vessels Hydrostatic Testing
H04 Tested at 1.5 *MAWP for 4 hours
•∘ Not included in base package Must include 100%
Post-Weld Heat PSV vents locally piped to safe elevation above top of cooler (discharge PSV’s) or safely above personnel height
Treatment (PWHT) radiography (E03) H05 •∘
E04 ASME coded vessels to be PWHT (suction & fuel PSV’s) c/w rain caps.
PSV Vent Piping
•∘ Not included in base package H06 PSV vents manifolded together into a common header and run to compressor end of skid
Sour Gas Trim
E05 Sour gas trim for <= 2% H2S mol. (20,000 PPMV) • Not included in base package
Inlet Suction
Screen Basket-style inlet suction screen with removable spool-piece to enable screen removal
H07 ∘
Option includes full-bore orifice plate (shipped loose) to replace screen upon removal in the field
2% Sour Gas Trim (Option E05)
Process Gas Valves / Accessories
To protect personnel and extend the service life of the package in corrosive hydrogen sulfide (H2S) gas service, Exterran has developed a
robust, pre-engineered option package that is now available with our C-Series product families. In applications where process gas includes • No suction relief valve included. Inlet protection by customer.
Suction
H2S concentrations up to and including 20,000ppm (2%), this option must be included. Integrated throughout many sub-systems of the Relief Valve Mercer suction PSV appropriately sized for maximum flow condition installed on scrubber inlet nozzle for ease of
I01 ∘
C-Series package, this option is a comprehensive combination of, material upgrades, NACE MR0175-compliant components, and additional suction spool/strainer removal (if applicable); includes PSV vent piped to top of scrubber with rain cap
safety systems. Highlights of the option include: I02 •∘ Manually operated bypass valve, KF full-port ball, flanged connections
Start-up
• Components compliant with NACE MR0175 (2002 edition) Bypass Valve Automatic bypass valve (pneumatically actuated), KF full-port ball, flanged connections Must select (D03) or
I03
Panel must be upgraded to Murphy Centurion Plus or CompactLogix PLC (D11) control panel
• No yellow metals in process gas system
• Ariel short-2-compartment (S2C) distance pieces I04 •∘ Manually operated blowdown valve, KF full-port ball, 2 inch NPT
Blowdown
• Purged cylinder pressure packing cases Valve Automatic blowdown valve (pneumatically actuated), KF full-port ball, 2 inch NPT Must select (D03) or
I05
• Cylinder flushing oil system Panel must be upgraded to Murphy Centurion Plus or CompactLogix PLC (D11) control panel
• Stainless steel piston rods •∘ Not included in base package
Recycle Valve
• 1 /8 inch corrosion allowance and 100% radiography on all process vessels, I06 Automatic Norriseal recycle valve (pneumatically actuated control-valve) sized for 50% of max flow
and cooler gas headers. 1/16 inch corrosion allowance on all process piping
•∘ Not included in base package
• All process gas relief valves are flanged Suction Block Valve
• Corrosion inhibitor connection on suction piping of each stage I07 Manual suction block valve (shipped loose for customer installation)

Discharge Block •∘ Not included in base package


Valve I08 Manual discharge block valve (shipped loose for customer installation)
Scrubbers •∘ Not included in base package
Discharge Check
F01 • Liquid drain valve only Valve
Liquid Drain I09 Manual discharge check valve (shipped loose for customer installation)
Valve System F02 External liquid drain valve with 1 inch NPT isolation ball valves included

•∘ Not included in base package Skid


Scrubber Insulate Blanket insulation of fuel filter and scrubber bottom, dump line and valves and electric heat trace J01 •∘ Four, (4) 1-1/2 inch FNPT drain connections, one located in each corner
F03 Skid Drains
& Heat Trace (220/240V, 1PH, 50/60HZ)
J02 Manifold four skid drains to a single 1-1/2 inch outlet at compressor-end of package
Blanket insulation of fuel filter and scrubber bottom, dump line and valves and heat trace with EJW
F04
Includes 1 inch pipe through scrubber & fuel filter for heating medium
Surface Prep & Paint
Pulsation Bottles K01 •∘ Exterran Gray using Exterran’s standard onshore paint and service prep
Paint Color
K02 Commercially available color of customer’s choice using Exterran’s standard onshore paint and service prep
•∘ No additional ports/valves for pulsation analysis
Pulsation
Analysis Ports G01 Kiene valves with caps on each cylinder (head end and crank end) and pulsation bottle heads (opposite inlet/outlet)
Drawings & Documentation
Package Service L01 •∘ Three CD copies of installation, operations and maintenance manual provided
Manuals L02 One printed copy and three CD copies of installation, operations and maintenance manual provided

12 Exterran.com 13
C-SERIES Configurable Compression Packages
Proven Quality and Reliability, Delivered Fast

DIMENSIONS
Top View
Overall skid length (shown in top view) is C D
the maximum assembled length of the unit.

Side View
This view represents the length of the skid
and the overall height of the assembled unit.

These illustrations show package with options


not included on base models. Cooler and exhaust
system are typically removed for shipping.
Dimensions shown here are approximate and may
vary. Precise measurements for freight permits
should be confirmed prior to shipping.
A

Dimensions
A B C D E
Skid Length Overall Length Skid Width Overall Width Height
Model
ft - in meters ft - in meters ft - in meters ft - in meters ft - in meters

3516 40 12.19 40 - 11 12.47 12 3.66 23 - 4 7.09 22 - 8 6.93

7044 41 12.50 41 - 11 12.72 14 - 6 4.41 25 - 9 7.85 25 - 8 7.84

ABOUT EXTERRAN
Exterran is a global leader in natural gas compression and a premier provider of equipment and services for petroleum production, gas
processing, produced water treatment and more. We also offer turnkey services for the design, fabrication, installation and operation of
complete production and processing facilities, as well as an extensive parts and service network. For more than 60 years Exterran has
built a legacy of proven performance. We have abundant worldwide resources, unmatched experience and technical expertise, and an
unwavering commitment to service. We help clients of all sizes reduce their operational and financial risks and achieve project success.

This brochure is intended for general information purposes only and is not intended as a
representation or warranty of any kind, or as a statement of any terms or conditions of sale.
Corporate Office The information herein is believed to be correct, but is not warranted for correctness or
4444 Brittmoore Rd. completeness, or for applicability to any particular customer or situation.
Houston, TX 77041 © Exterran Corporation All Rights Reserved C-SERIES-TEC-JL15-JE

Potrebbero piacerti anche