Sei sulla pagina 1di 3

HUAWEI

1. To check running config of switch:


[Huawei]display current-configuration

2.To check interface status:


[Huawei]display interface description

3.To check Loop or spanning tree:


[Huawei]display stp interface GigabitEthernet 0/0/--

4.To check Optical power reveciving at any Interface and type of SFP:
[Huawei]display transceiver interface <GigabitEthernet 0/0/-- or XGigabitEthernet 0/0/--> verbose

5.To check running config of interface:


[Huawei]display current-configuration <GigabitEthernet 0/0/-- or XGigabitEthernet 0/0/-->

6.To add single vlan in trunk interface:


[Huawei]interface <GigabitEthernet 0/0/-- or XGigabitEthernet 0/0/-->
[Huawei-<GigabitEthernet 0/0/-- or XGigabitEthernet 0/0/-->]port trunk allow-pass vlan <vlan-id>

7.To remove single vlan from trunk interface:


[Huawei]interface <GigabitEthernet 0/0/-- or XGigabitEthernet 0/0/-->
[Huawei <GigabitEthernet 0/0/-- or XGigabitEthernet 0/0/-->]undo port trunk allow-pass vlan <vlanid>
DBC OLT

1. To check online onu:


from MAC-address
Epon#sh epon active-onu mac-address xxxx.xxxx.xxxx
from Interface
Epon#show epon active-onu interface ePON 0/<pon port no.>

2.To check running config of onu:


Epon#show running-config interface ePON 0/<pon port> : <onu id>

3. To check optical power of onu:


Epon#show epon optical-transceiver-diagnosis interface epON 0/<pon port> : <onu id>

4.To configure onu:


Epon# config
Epon_config#int epon 0/<pon port> : <onu id>
Epon_config_epon0/<pon port>:<onu id># epon onu port <onu port no.> ctc vlan mode tag <vlan id>
Epon_config_epon0/<pon port>:<onu id># epon onu port <onu port no.> ctc loopback detect

INOTECH OLT/OPTILINK OLT

1.To check online onu:


#show olt <pon port no> online-onu
or
#show onu-position xx-xx-xx-xx-xx-xx

2.To check optical power of onu:


#show olt <pon port no> onu <onu id> ctc optical

3.To check running config of onu:


#show running-config onu <pon port no> <onu id>

4.To check Loop :


#show system log type onu-uni-loopback-alarm

OPTILINK
To check optical power of all onu:
#show olt <pon port no> ctc optical
SYROTECH OLT

1.ONU Config:

(Config)#Int epon0/1
onu <onu-id> ctc eth <onu-port> vlan mode tag
onu <onu-id> ctc eth <onu-port> vlan pvid <vlan id> pri 0
onu <onu-id> description ----

2.To check optical power of onu:


(Config)#show onu opm-diag pon <pon-port-no>

3.To check online onu :


(config )# show onu auth-info all

4.To check running config of onu:


(config-pon-0/1)# show running-config onu 1