It is the impact of moving water in steam line when the steam is allowed to
enter a line with condensed water.
The steam will condenses and partial vacuum occurred and move back the
water the along the pipe with very high velocity, and the water will strike at the
vent or valves.
To prevent the water hummer –
Slowly open the salinometer cock until clean hot water coming out.
Then collect the boiler sample with copper jar.
Where is manhole doors fitted?
They are fitted at one at steam side and other one for water side.
Hydraulic pressure test is 1.25 times working pressure, (10 minutes maintain)
1. Close all openings.
2. Open air vent cock.
3. Fill up boiler water fully
4. Close the air vent cock
5. Place hydraulic jack to feed water line.
6. Fit standard pressure gauge.
7. Applied hydraulic pressure 1.25 times of working pressure and maintain
10minutes.
1. By regulating the amount of gas flowing over the extended surface, i.e. by
damper regulation.
2. By dividing the unit into sections so that each section is controlled by an inlet
valve.
3. By passing steam through an automatic pressure controlled surplus valve to a
dump condenser.
4. By a system designed for a higher pressure than that it is to operate.
Checked its valve and valve seat for wear, cavity corrosion and any fault.
They should be grounded properly but maker’s limit must be maintained such
as width of seating, clearance between valve lip and seat.
Valve chest must be cleaned condition and drain line clear.
The spring should be hammer tested for any fracture and check for corrosion.
Free length is limited to 0.5 % of original free length.
The spindle should be hammer tested for any crack and its straightness.
The guide plates and bushes are checked for uneven wear and have sufficient
clearance to allow free movement of spindle.
The compression nut and cover bush’s threads are carefully checked it for any
sign of wear and tear.
The easing gear should be checked in good order including bearings, cable
pulley, and connecting links.
Connecting pin should be a free fit in the lid and pin should not bent or
pinhole gone out of shape.
All safety valves are to be set to operate under steam a little above working
pressure not greater than 3% above the approve working pressure of the boiler.
Why safety valve is fitted in two numbers?
To make sure that the positive discharging of higher steam pressure from
boiler efficiency.