Physical characteristics
1.Min. bending radius(mm)
a)during installation: 178
b)after installation: 142
2.Max. pulling tension for conductor(kN): 2.240
3.Construction test: AS/NZS 5000.1
4.Flame retardant test: AS/NZS 1660.5.6
Packing information
1.Max. cable length per drum(m): 300
2.Drum size(mm): 800 x 400 x 800
3.Gross weight per drum(kg): 220
4.No. of drums: 1
Contact Information Customer Approved by
Address: 27 Senoko way
Singapore 758060
Tel: (65) 6367 0107
Fax: (65) 6365 2963
Email: sales@keystone-cable.com
Website: www.keystone-cable.com
Spec.No Prepared by Checked by Approved by
S-130617-01C SongKunhua YuLei Patrick Li
NOTE:The information contained in this data sheet is subject to normal manufacturing tolerance, specifications are subject to change without notice.
SPECIFICATION
SIEMENS MTO ITEM No.: A4
POWER CABLE: 2C X 25 mm2
CU/XLPE/PVC,Unarmoured
Cross Drawing
Description
Physical characteristics
1.Min. bending radius(mm)
a)during installation: 210
b)after installation: 168
2.Max. pulling tension for conductor(kN): 3.500
3.Construction test: AS/NZS 5000.1
4.Flame retardant test: AS/NZS 1660.5.6
Packing information
1.Max. cable length per drum(m): 500
2.Drum size(mm): 1000 x 500 x 1000
3.Gross weight per drum(kg): 440
4.No. of drums: 1
Contact Information Customer Approved by
Address: 27 Senoko way
Singapore 758060
Tel: (65) 6367 0107
Fax: (65) 6365 2963
Email: sales@keystone-cable.com
Website: www.keystone-cable.com
Spec.No Prepared by Checked by Approved by
S-130617-02C SongKunhua YuLei Patrick Li
NOTE:The information contained in this data sheet is subject to normal manufacturing tolerance, specifications are subject to change without notice.
SPECIFICATION
SIEMENS MTO ITEM No.: A31
POWER CABLE: 2C X 4 + E X 2.5 mm2
CU/XLPE/PVC,Unarmoured
Cross Drawing
Description
Physical characteristics
1.Min. bending radius(mm)
a)during installation: 147
b)after installation: 118
2.Max. pulling tension for conductor(kN): 0.735
3.Construction test: AS/NZS 5000.1
4.Flame retardant test: AS/NZS 1660.5.6
Packing information
1.Max. cable length per drum(m): 600
2.Drum size(mm): 900 x 450 x 900
3.Gross weight per drum(kg): 240
4.No. of drums: 1
Contact Information Customer Approved by
Address: 27 Senoko way
Singapore 758060
Tel: (65) 6367 0107
Fax: (65) 6365 2963
Email: sales@keystone-cable.com
Website: www.keystone-cable.com
Spec.No Prepared by Checked by Approved by
S-130617-03C SongKunhua YuLei Patrick Li
NOTE:The information contained in this data sheet is subject to normal manufacturing tolerance, specifications are subject to change without notice.
SPECIFICATION
SIEMENS MTO ITEM No.: A56
POWER CABLE: 2C X 300 + E X 120 mm2
CU/XLPE/PVC,Unarmoured
Cross Drawing
Description
Physical characteristics
1.Min. bending radius(mm)
a)during installation: 720
b)after installation: 600
2.Max. pulling tension for conductor(kN): 50.400
3.Construction test: AS/NZS 5000.1
4.Flame retardant test: AS/NZS 1660.5.6
Packing information
1.Max. cable length per drum(m): 400
2.Drum size(mm): 2240 x 1400 x 2240
3.Gross weight per drum(kg): 3380
4.No. of drums: 1
Contact Information Customer Approved by
Address: 27 Senoko way
Singapore 758060
Tel: (65) 6367 0107
Fax: (65) 6365 2963
Email: sales@keystone-cable.com
Website: www.keystone-cable.com
Spec.No Prepared by Checked by Approved by
S-130617-04C SongKunhua YuLei Patrick Li
NOTE:The information contained in this data sheet is subject to normal manufacturing tolerance, specifications are subject to change without notice.
SPECIFICATION
SIEMENS MTO ITEM No.: A16
POWER CABLE: 3C X 16 + E X 6 mm2
CU/XLPE/PVC,Unarmoured
Cross Drawing
Description
Physical characteristics
1.Min. bending radius(mm)
a)during installation: 205
b)after installation: 164
2.Max. pulling tension for conductor(kN): 3.780
3.Construction test: AS/NZS 5000.1
4.Flame retardant test: AS/NZS 1660.5.6
Packing information
1.Max. cable length per drum(m): 200
2.Drum size(mm): 800 x 400 x 800
3.Gross weight per drum(kg): 210
4.No. of drums: 1
Contact Information Customer Approved by
Address: 27 Senoko way
Singapore 758060
Tel: (65) 6367 0107
Fax: (65) 6365 2963
Email: sales@keystone-cable.com
Website: www.keystone-cable.com
Spec.No Prepared by Checked by Approved by
S-130617-05C SongKunhua YuLei Patrick Li
NOTE:The information contained in this data sheet is subject to normal manufacturing tolerance, specifications are subject to change without notice.
SPECIFICATION
SIEMENS MTO ITEM No.: A37
POWER CABLE: 3C X 50 + E X 16 mm2
CU/XLPE/PVC,Unarmoured
Cross Drawing
Description
Physical characteristics
1.Min. bending radius(mm)
a)during installation: 366
b)after installation: 305
2.Max. pulling tension for conductor(kN): 11.620
3.Construction test: AS/NZS 5000.1
4.Flame retardant test: AS/NZS 1660.5.6
Packing information
1.Max. cable length per drum(m): 200
2.Drum size(mm): 1120 x 630 x 1120
3.Gross weight per drum(kg): 470
4.No. of drums: 1
Contact Information Customer Approved by
Address: 27 Senoko way
Singapore 758060
Tel: (65) 6367 0107
Fax: (65) 6365 2963
Email: sales@keystone-cable.com
Website: www.keystone-cable.com
Spec.No Prepared by Checked by Approved by
S-130617-06C SongKunhua YuLei Patrick Li
NOTE:The information contained in this data sheet is subject to normal manufacturing tolerance, specifications are subject to change without notice.
SPECIFICATION
SIEMENS MTO ITEM No.: A57
POWER CABLE: 3C X 300 + E X 120 mm2
CU/XLPE/PVC,Unarmoured
Cross Drawing
Description
Physical characteristics
1.Min. bending radius(mm)
a)during installation: 792
b)after installation: 660
2.Max. pulling tension for conductor(kN): 71.400
3.Construction test: AS/NZS 5000.1
4.Flame retardant test: AS/NZS 1660.5.6
Packing information
1.Max. cable length per drum(m): 200
2.Drum size(mm): 2000 x 1400 x 2000
3.Gross weight per drum(kg): 2360
4.No. of drums: 1
Contact Information Customer Approved by
Address: 27 Senoko way
Singapore 758060
Tel: (65) 6367 0107
Fax: (65) 6365 2963
Email: sales@keystone-cable.com
Website: www.keystone-cable.com
Spec.No Prepared by Checked by Approved by
S-130617-07C SongKunhua YuLei Patrick Li
NOTE:The information contained in this data sheet is subject to normal manufacturing tolerance, specifications are subject to change without notice.
SPECIFICATION
SIEMENS MTO ITEM No.: B3
POWER CABLE: 2C X 2.5 + E X 2.5 mm2
CU/XLPE/PVC/SWA/PVC,Armoured
Cross Drawing
Description
Description
Packing information
1.Max. length per drum(m): 2000
2.Drum size(H x W x L)(mm): 1250 x 710 x 1250
3.Gross weight per drum(kg): 610
4.No. of drums: 1
Description
Packing information
1.Max. length per drum(m): 3000
2.Drum size(H x W x L)(mm): 1250 x 630 x 1250
3.Gross weight per drum(kg): 440
4.No. of drums: 3
Description
Packing information
1.Max. length per drum(m): 2000
2.Drum size(H x W x L)(mm): 1120 x 560 x 1120
3.Gross weight per drum(kg): 540
4.No. of drums: 1
Description
Packing information
1.Max. length per drum(m): 2500
2.Drum size(H x W x L)(mm): 1600 x 1000 x 1600
3.Gross weight per drum(kg): 1040
4.No. of drums: 3
Description
Description
No. of Cores 1
Conductor
Material: Plain annealed copper wire Insulation: Green/yellow
2 70
Cross-Sectional Area(mm ):
Approx. Conductor Dia.(mm): 9.8
Class of Conductor: Class 2
Insulation Performance
Material: PVC(V-90) Electrical characteristics
Nom. Thickness(mm): 1.4 1.Max. Conductor D.C. resistance at 20℃(Ω/km): 0.268
Min. Thickness(mm): 1.16 2.Min. Insulation Resistance at 20℃(MΩ•km): 10
Approx. Dia. of cable(mm): 12.8 3.Spark test A.C. voltage value(kV): 10
Approx. weight of cable(kg/km): 700.0 4.A.C. high voltage test for 5min(kV): 2.5
Order Quantity(m): 500
Physical characteristics
1.Min. bending radius(mm)
a)during installation: 128
b)after installation: 102
2.Max. pulling tension for conductor(kN): 4.900
3.Construction test: AS/NZS 5000.1
4.Flame retardant test: AS/NZS 1660.5.6
Packing information
1.Max. cable length per drum(m): 500
2.Drum size(mm): 800 x 400 x 800
3.Gross weight per drum(kg): 420
4.No. of drums: 1
Description
Description