Sei sulla pagina 1di 16

SPECIFICATION

SIEMENS MTO ITEM No.: A3


POWER CABLE: 2C X 16 mm2
CU/XLPE/PVC,Unarmoured
Cross Drawing

Description

Application:This cable is primarily used for main power supply.It can be


installed in cable ducts,in cable trunking,on cable trays,and on cable
ladders.

Rated Voltage(V): 600/1000


Rated Temperature(℃): 90
Generally refer to specification: AS/NZS 5000.1、AS/NZS 1125
AS/NZS 3808、AS/NZS 1660.5.6

Cable Construction Color

No. of Cores 2 Insulation: Red、Black


Conductor
Material: Plain annealed copper wire
Cross-Sectional Area(mm2): 16 Outer sheath: Black(UV-Stabilised)
Approx. Conductor Dia.(mm): 5.1
Class of Conductor: Class 2 Performance
Insulation Electrical characteristics
Material: XLPE(X-90) 1.Max. Conductor D.C. resistance at 20℃(Ω/km): 1.15
Nom. Thickness(mm): 0.7 2.Max. Conductor A.C. resistance at 90℃(Ω/km): 1.47
Approx. Dia. over insulation(mm): 6.6 3.Min. Insulation Resistance at 20℃(MΩ•km): 1000
Outer Sheath 4.Spark test A.C. voltage value(kV): 6
Material: PVC(5V-90) 5.A.C. high voltage test for 5min(kV): 3.5
Nom. Thickness(mm): 1.8 6.Current carrying capacities(A)
Min. Thickness(mm): 1.43 a)in air: 97
Approx. Dia. of cable(mm): 17.8 b)direct buried: 132
O.D. tolerance(%): ±8 c)buried in duct: 98
Approx. Weight of cable(kg/km): 495.0 *Ambient temperature:40℃;Ground temperature:25℃
Order Quantity(m): 300 Burying depth:1 m;Soil resistivity:1℃•m/w
7.Max. conductor temperature of 5s Short-circuit(℃): 250
8.Max. 1s Short-circuit rating(kA): 1.824
9.Reactance at 50Hz(Ω/km): 0.0805

Physical characteristics
1.Min. bending radius(mm)
a)during installation: 178
b)after installation: 142
2.Max. pulling tension for conductor(kN): 2.240
3.Construction test: AS/NZS 5000.1
4.Flame retardant test: AS/NZS 1660.5.6
Packing information
1.Max. cable length per drum(m): 300
2.Drum size(mm): 800 x 400 x 800
3.Gross weight per drum(kg): 220
4.No. of drums: 1
Contact Information Customer Approved by
Address: 27 Senoko way
Singapore 758060
Tel: (65) 6367 0107
Fax: (65) 6365 2963
Email: sales@keystone-cable.com
Website: www.keystone-cable.com
Spec.No Prepared by Checked by Approved by
S-130617-01C SongKunhua YuLei Patrick Li
NOTE:The information contained in this data sheet is subject to normal manufacturing tolerance, specifications are subject to change without notice.
SPECIFICATION
SIEMENS MTO ITEM No.: A4
POWER CABLE: 2C X 25 mm2
CU/XLPE/PVC,Unarmoured
Cross Drawing

Description

Application:This cable is primarily used for main power supply.It can be


installed in cable ducts,in cable trunking,on cable trays,and on cable
ladders.

Rated Voltage(V): 600/1000


Rated Temperature(℃): 90
Generally refer to specification: AS/NZS 5000.1、AS/NZS 1125
AS/NZS 3808、AS/NZS 1660.5.6

Cable Construction Color

No. of Cores 2 Insulation: Red、Black


Conductor
Material: Plain annealed copper wire
Cross-Sectional Area(mm2): 25 Outer sheath: Black(UV-Stabilised)
Approx. Conductor Dia.(mm): 6.15
Class of Conductor: Class 2 Performance
Insulation Electrical characteristics
Material: XLPE(X-90) 1.Max. Conductor D.C. resistance at 20℃(Ω/km): 0.727
Nom. Thickness(mm): 0.9 2.Max. Conductor A.C. resistance at 90℃(Ω/km): 0.927
Approx. Dia. over insulation(mm): 8.1 3.Min. Insulation Resistance at 20℃(MΩ•km): 1000
Outer Sheath 4.Spark test A.C. voltage value(kV): 6
Material: PVC(5V-90) 5.A.C. high voltage test for 5min(kV): 3.5
Nom. Thickness(mm): 1.8 6.Current carrying capacities(A)
Min. Thickness(mm): 1.43 a)in air: 131
Approx. Dia. of cable(mm): 21.0 b)direct buried: 170
O.D. tolerance(%): ±8 c)buried in duct: 128
Approx. Weight of cable(kg/km): 715.0 *Ambient temperature:40℃;Ground temperature:25℃
Order Quantity(m): 500 Burying depth:1 m;Soil resistivity:1℃•m/w
7.Max. conductor temperature of 5s Short-circuit(℃): 250
8.Max. 1s Short-circuit rating(kA): 2.850
9.Reactance at 50Hz(Ω/km): 0.0808

Physical characteristics
1.Min. bending radius(mm)
a)during installation: 210
b)after installation: 168
2.Max. pulling tension for conductor(kN): 3.500
3.Construction test: AS/NZS 5000.1
4.Flame retardant test: AS/NZS 1660.5.6
Packing information
1.Max. cable length per drum(m): 500
2.Drum size(mm): 1000 x 500 x 1000
3.Gross weight per drum(kg): 440
4.No. of drums: 1
Contact Information Customer Approved by
Address: 27 Senoko way
Singapore 758060
Tel: (65) 6367 0107
Fax: (65) 6365 2963
Email: sales@keystone-cable.com
Website: www.keystone-cable.com
Spec.No Prepared by Checked by Approved by
S-130617-02C SongKunhua YuLei Patrick Li
NOTE:The information contained in this data sheet is subject to normal manufacturing tolerance, specifications are subject to change without notice.
SPECIFICATION
SIEMENS MTO ITEM No.: A31
POWER CABLE: 2C X 4 + E X 2.5 mm2
CU/XLPE/PVC,Unarmoured
Cross Drawing

Description

Application:This cable is primarily used for main power supply.It can be


installed in cable ducts,in cable trunking,on cable trays,and on cable
ladders.

Rated Voltage(V): 600/1000


Rated Temperature(℃): 90
Generally refer to specification: AS/NZS 5000.1、AS/NZS 1125
AS/NZS 3808、AS/NZS 1660.5.6

Cable Construction Color


Phase cores Earth core Insulation: Red、Black、Green/yellow
No. of Cores 2 1
Conductor
Material: Plain annealed copper wire
Cross-Sectional Area(mm2): 4 2.5 Outer sheath: Black(UV-Stabilised)
Approx. Conductor Dia.(mm): 2.55 2.01 Performance
Class of Conductor: Class 2 Electrical characteristics
Insulation Phase cores Earth core
Material: XLPE(X-90) 1.Max. Conductor D.C. resistance at 20℃(Ω/km): 4.61 7.41
Nom. Thickness(mm): 0.7 0.7 2.Max. Conductor A.C. resistance at 90℃(Ω/km): 5.88 9.45
Approx. Dia. over insulation(mm): 4.6 3.5 3.Min. Insulation Resistance at 20℃(MΩ•km): 1000
Outer Sheath 4.Spark test A.C. voltage value(kV): 6 6
Material: PVC(5V-90) 5.A.C. high voltage test for 5min(kV): 3.5
Nom. Thickness(mm): 1.8 6.Current carrying capacities(A)
Min. Thickness(mm): 1.43 a)in air: 42
Approx. Dia. of cable(mm): 14.7 b)direct buried: 45
O.D. tolerance(%): ±8 c)buried in duct: 45
Approx. Weight of cable(kg/km): 290.0 *Ambient temperature:40℃;Ground temperature:25℃
Order Quantity(m): 600 Burying depth:1 m;Soil resistivity:1℃•m/w
7.Max. conductor temperature of 5s Short-circuit(℃): 250
8.Max. 1s Short-circuit rating(kA): 0.456
9.Reactance at 50Hz(Ω/km): 0.0930

Physical characteristics
1.Min. bending radius(mm)
a)during installation: 147
b)after installation: 118
2.Max. pulling tension for conductor(kN): 0.735
3.Construction test: AS/NZS 5000.1
4.Flame retardant test: AS/NZS 1660.5.6
Packing information
1.Max. cable length per drum(m): 600
2.Drum size(mm): 900 x 450 x 900
3.Gross weight per drum(kg): 240
4.No. of drums: 1
Contact Information Customer Approved by
Address: 27 Senoko way
Singapore 758060
Tel: (65) 6367 0107
Fax: (65) 6365 2963
Email: sales@keystone-cable.com
Website: www.keystone-cable.com
Spec.No Prepared by Checked by Approved by
S-130617-03C SongKunhua YuLei Patrick Li
NOTE:The information contained in this data sheet is subject to normal manufacturing tolerance, specifications are subject to change without notice.
SPECIFICATION
SIEMENS MTO ITEM No.: A56
POWER CABLE: 2C X 300 + E X 120 mm2
CU/XLPE/PVC,Unarmoured
Cross Drawing

Description

Application:This cable is primarily used for main power supply.It can be


installed in cable ducts,in cable trunking,on cable trays,and on cable
ladders.

Rated Voltage(V): 600/1000


Rated Temperature(℃): 90
Generally refer to specification: AS/NZS 5000.1、AS/NZS 1125
AS/NZS 3808、AS/NZS 1660.5.6

Cable Construction Color


Phase cores Earth core Insulation: Red、Black、Green/yellow
No. of Cores 2 1
Conductor
Material: Plain annealed copper wire
Cross-Sectional Area(mm2): 300 120 Outer sheath: Black(UV-Stabilised)
Approx. Conductor Dia.(mm): 21.2 13.0 Performance
Class of Conductor: Class 2 Electrical characteristics
Insulation Phase cores Earth core
Material: XLPE(X-90) 1.Max. Conductor D.C. resistance at 20℃(Ω/km): 0.0601 0.153
Nom. Thickness(mm): 1.8 1.2 2.Max. Conductor A.C. resistance at 90℃(Ω/km): 0.0766 0.195
Approx. Dia. over insulation(mm): 25.1 15.4 3.Min. Insulation Resistance at 20℃(MΩ•km): 1000
Outer Sheath 4.Spark test A.C. voltage value(kV): 15 10
Material: PVC(5V-90) 5.A.C. high voltage test for 5min(kV): 3.5
Nom. Thickness(mm): 2.6 6.Current carrying capacities(A)
Min. Thickness(mm): 2.11 a)in air: 645
Approx. Dia. of cable(mm): 60.0 b)direct buried: 680
O.D. tolerance(%): ±8 c)buried in duct: 558
Approx. Weight of cable(kg/km): 7970.0 *Ambient temperature:40℃;Ground temperature:25℃
Order Quantity(m): 400 Burying depth:1 m;Soil resistivity:1℃•m/w
7.Max. conductor temperature of 5s Short-circuit(℃): 250
8.Max. 1s Short-circuit rating(kA): 34.200
9.Reactance at 50Hz(Ω/km): 0.0704

Physical characteristics
1.Min. bending radius(mm)
a)during installation: 720
b)after installation: 600
2.Max. pulling tension for conductor(kN): 50.400
3.Construction test: AS/NZS 5000.1
4.Flame retardant test: AS/NZS 1660.5.6
Packing information
1.Max. cable length per drum(m): 400
2.Drum size(mm): 2240 x 1400 x 2240
3.Gross weight per drum(kg): 3380
4.No. of drums: 1
Contact Information Customer Approved by
Address: 27 Senoko way
Singapore 758060
Tel: (65) 6367 0107
Fax: (65) 6365 2963
Email: sales@keystone-cable.com
Website: www.keystone-cable.com
Spec.No Prepared by Checked by Approved by
S-130617-04C SongKunhua YuLei Patrick Li
NOTE:The information contained in this data sheet is subject to normal manufacturing tolerance, specifications are subject to change without notice.
SPECIFICATION
SIEMENS MTO ITEM No.: A16
POWER CABLE: 3C X 16 + E X 6 mm2
CU/XLPE/PVC,Unarmoured
Cross Drawing

Description

Application:This cable is primarily used for main power supply.It can be


installed in cable ducts,in cable trunking,on cable trays,and on cable
ladders.

Rated Voltage(V): 600/1000


Rated Temperature(℃): 90
Generally refer to specification: AS/NZS 5000.1、AS/NZS 1125
AS/NZS 3808、AS/NZS 1660.5.6

Cable Construction Color


Phase cores Earth core Insulation: Red、White、Blue、Green/yellow
No. of Cores 3 1
Conductor
Material: Plain annealed copper wire
Cross-Sectional Area(mm2): 16 6 Outer sheath: Black(UV-Stabilised)
Approx. Conductor Dia.(mm): 5.1 3.12 Performance
Class of Conductor: Class 2 Electrical characteristics
Insulation Phase cores Earth core
Material: XLPE(X-90) 1.Max. Conductor D.C. resistance at 20℃(Ω/km): 1.15 3.08
Nom. Thickness(mm): 0.7 0.7 2.Max. Conductor A.C. resistance at 90℃(Ω/km): 1.47 3.93
Approx. Dia. over insulation(mm): 6.6 4.6 3.Min. Insulation Resistance at 20℃(MΩ•km): 1000
Outer Sheath 4.Spark test A.C. voltage value(kV): 6 6
Material: PVC(5V-90) 5.A.C. high voltage test for 5min(kV): 3.5
Nom. Thickness(mm): 1.8 6.Current carrying capacities(A)
Min. Thickness(mm): 1.43 a)in air: 83
Approx. Dia. of cable(mm): 20.5 b)direct buried: 110
O.D. tolerance(%): ±8 c)buried in duct: 81
Approx. Weight of cable(kg/km): 735.0 *Ambient temperature:40℃;Ground temperature:25℃
Order Quantity(m): 200 Burying depth:1 m;Soil resistivity:1℃•m/w
7.Max. conductor temperature of 5s Short-circuit(℃): 250
8.Max. 1s Short-circuit rating(kA): 1.824
9.Reactance at 50Hz(Ω/km): 0.0805

Physical characteristics
1.Min. bending radius(mm)
a)during installation: 205
b)after installation: 164
2.Max. pulling tension for conductor(kN): 3.780
3.Construction test: AS/NZS 5000.1
4.Flame retardant test: AS/NZS 1660.5.6
Packing information
1.Max. cable length per drum(m): 200
2.Drum size(mm): 800 x 400 x 800
3.Gross weight per drum(kg): 210
4.No. of drums: 1
Contact Information Customer Approved by
Address: 27 Senoko way
Singapore 758060
Tel: (65) 6367 0107
Fax: (65) 6365 2963
Email: sales@keystone-cable.com
Website: www.keystone-cable.com
Spec.No Prepared by Checked by Approved by
S-130617-05C SongKunhua YuLei Patrick Li
NOTE:The information contained in this data sheet is subject to normal manufacturing tolerance, specifications are subject to change without notice.
SPECIFICATION
SIEMENS MTO ITEM No.: A37
POWER CABLE: 3C X 50 + E X 16 mm2
CU/XLPE/PVC,Unarmoured
Cross Drawing

Description

Application:This cable is primarily used for main power supply.It can be


installed in cable ducts,in cable trunking,on cable trays,and on cable
ladders.

Rated Voltage(V): 600/1000


Rated Temperature(℃): 90
Generally refer to specification: AS/NZS 5000.1、AS/NZS 1125
AS/NZS 3808、AS/NZS 1660.5.6

Cable Construction Color


Phase cores Earth core Insulation: Red、White、Blue、Green/yellow
No. of Cores 3 1
Conductor
Material: Plain annealed copper wire
Cross-Sectional Area(mm2): 50 16 Outer sheath: Black(UV-Stabilised)
Approx. Conductor Dia.(mm): 8.5 5.1 Performance
Class of Conductor: Class 2 Electrical characteristics
Insulation Phase cores Earth core
Material: XLPE(X-90) 1.Max. Conductor D.C. resistance at 20℃(Ω/km): 0.387 1.15
Nom. Thickness(mm): 1.0 0.7 2.Max. Conductor A.C. resistance at 90℃(Ω/km): 0.493 1.47
Approx. Dia. over insulation(mm): 10.6 6.6 3.Min. Insulation Resistance at 20℃(MΩ•km): 1000
Outer Sheath 4.Spark test A.C. voltage value(kV): 10 6
Material: PVC(5V-90) 5.A.C. high voltage test for 5min(kV): 3.5
Nom. Thickness(mm): 1.8 6.Current carrying capacities(A)
Min. Thickness(mm): 1.43 a)in air: 168
Approx. Dia. of cable(mm): 30.5 b)direct buried: 204
O.D. tolerance(%): ±8 c)buried in duct: 155
Approx. Weight of cable(kg/km): 1870.0 *Ambient temperature:40℃;Ground temperature:25℃
Order Quantity(m): 200 Burying depth:1 m;Soil resistivity:1℃•m/w
7.Max. conductor temperature of 5s Short-circuit(℃): 250
8.Max. 1s Short-circuit rating(kA): 5.700
9.Reactance at 50Hz(Ω/km): 0.0751

Physical characteristics
1.Min. bending radius(mm)
a)during installation: 366
b)after installation: 305
2.Max. pulling tension for conductor(kN): 11.620
3.Construction test: AS/NZS 5000.1
4.Flame retardant test: AS/NZS 1660.5.6
Packing information
1.Max. cable length per drum(m): 200
2.Drum size(mm): 1120 x 630 x 1120
3.Gross weight per drum(kg): 470
4.No. of drums: 1
Contact Information Customer Approved by
Address: 27 Senoko way
Singapore 758060
Tel: (65) 6367 0107
Fax: (65) 6365 2963
Email: sales@keystone-cable.com
Website: www.keystone-cable.com
Spec.No Prepared by Checked by Approved by
S-130617-06C SongKunhua YuLei Patrick Li
NOTE:The information contained in this data sheet is subject to normal manufacturing tolerance, specifications are subject to change without notice.
SPECIFICATION
SIEMENS MTO ITEM No.: A57
POWER CABLE: 3C X 300 + E X 120 mm2
CU/XLPE/PVC,Unarmoured
Cross Drawing

Description

Application:This cable is primarily used for main power supply.It can be


installed in cable ducts,in cable trunking,on cable trays,and on cable
ladders.

Rated Voltage(V): 600/1000


Rated Temperature(℃): 90
Generally refer to specification: AS/NZS 5000.1、AS/NZS 1125
AS/NZS 3808、AS/NZS 1660.5.6

Cable Construction Color


Phase cores Earth core Insulation: Red、White、Blue、Green/yellow
No. of Cores 3 1
Conductor
Material: Plain annealed copper wire
Cross-Sectional Area(mm2): 300 120 Outer sheath: Black(UV-Stabilised)
Approx. Conductor Dia.(mm): 21.2 13.0 Performance
Class of Conductor: Class 2 Electrical characteristics
Insulation Phase cores Earth core
Material: XLPE(X-90) 1.Max. Conductor D.C. resistance at 20℃(Ω/km): 0.0601 0.153
Nom. Thickness(mm): 1.8 1.2 2.Max. Conductor A.C. resistance at 90℃(Ω/km): 0.0766 0.195
Approx. Dia. over insulation(mm): 25.1 15.4 3.Min. Insulation Resistance at 20℃(MΩ•km): 1000
Outer Sheath 4.Spark test A.C. voltage value(kV): 15 10
Material: PVC(5V-90) 5.A.C. high voltage test for 5min(kV): 3.5
Nom. Thickness(mm): 2.8 6.Current carrying capacities(A)
Min. Thickness(mm): 2.28 a)in air: 549
Approx. Dia. of cable(mm): 66.0 b)direct buried: 567
O.D. tolerance(%): ±8 c)buried in duct: 463
Approx. Weight of cable(kg/km): 10980.0 *Ambient temperature:40℃;Ground temperature:25℃
Order Quantity(m): 200 Burying depth:1 m;Soil resistivity:1℃•m/w
7.Max. conductor temperature of 5s Short-circuit(℃): 250
8.Max. 1s Short-circuit rating(kA): 34.200
9.Reactance at 50Hz(Ω/km): 0.0704

Physical characteristics
1.Min. bending radius(mm)
a)during installation: 792
b)after installation: 660
2.Max. pulling tension for conductor(kN): 71.400
3.Construction test: AS/NZS 5000.1
4.Flame retardant test: AS/NZS 1660.5.6
Packing information
1.Max. cable length per drum(m): 200
2.Drum size(mm): 2000 x 1400 x 2000
3.Gross weight per drum(kg): 2360
4.No. of drums: 1
Contact Information Customer Approved by
Address: 27 Senoko way
Singapore 758060
Tel: (65) 6367 0107
Fax: (65) 6365 2963
Email: sales@keystone-cable.com
Website: www.keystone-cable.com
Spec.No Prepared by Checked by Approved by
S-130617-07C SongKunhua YuLei Patrick Li
NOTE:The information contained in this data sheet is subject to normal manufacturing tolerance, specifications are subject to change without notice.
SPECIFICATION
SIEMENS MTO ITEM No.: B3
POWER CABLE: 2C X 2.5 + E X 2.5 mm2
CU/XLPE/PVC/SWA/PVC,Armoured
Cross Drawing

Description

Application:This cable is primarily used for main power supply.It can be


installed in cable ducts,in cable trunking,on cable trays,and on cable
ladders.

Rated Voltage(V): 600/1000


Rated Temperature(℃): 90
Generally refer to specification: AS/NZS 5000.1、AS/NZS 1125
AS/NZS 3808、AS/NZS 1660.5.6

Cable Construction Color


Phase cores Earth core Insulation: Red、Black、Green/yellow
No. of Cores 2 1
Conductor Bedding: Black
Material: Plain annealed copper wire
Cross-Sectional Area(mm2): 2.5 2.5 Outer sheath: Black(UV-Stabilised)
Approx. Conductor Dia.(mm): 2.01 2.01 Performance
Class of Conductor: Class 2 Electrical characteristics
Insulation Phase cores Earth core
Material: XLPE(X-90) 1.Max. Conductor D.C. resistance at 20℃(Ω/km): 7.41 7.41
Nom. Thickness(mm): 0.7 0.7 2.Max. Conductor A.C. resistance at 90℃(Ω/km): 9.45 9.45
Approx. Dia. over insulation(mm): 3.5 3.5 3.Min. Insulation Resistance at 20℃(MΩ•km): 1000
Bedding 4.Spark test A.C. voltage value(kV): 6 6
Material: PVC(5V-90) 5.A.C. high voltage test for 5min(kV): 3.5
Nom. Thickness(mm): 1.0 6.Current carrying capacities(A)
Approx. Dia. over bedding(mm): 10.6 a)in air: 27
Armour b)direct buried: 34
Material of Armour: Galvanized steel wire c)buried in duct: 34
Dia. of Armour wire: 0.8 *Ambient temperature:40℃;Ground temperature:25℃
Approx. Dia. over armour(mm): 12.2 Burying depth:1 m;Soil resistivity:1℃•m/w
Outer Sheath 7.Max. conductor temperature of 5s Short-circuit(℃): 250
Material: PVC(5V-90) 8.Max. 1s Short-circuit rating(kA): 0.2280
Nom. Thickness(mm): 1.8 9.Reactance at 50Hz(Ω/km): 0.0988
Min. Thickness(mm): 1.24
Approx. Dia. of cable(mm): 16.8 Physical characteristics
O.D. tolerance(%): ±8 1.Min. bending radius(mm)
Approx. Weight of cable(kg/km): 440.0 a)during installation: 202
Order Quantity(m): 1000 b)after installation: 168
2.Max. pulling tension for conductor(kN): 0.525
3.Construction test: AS/NZS 5000.1
4.Flame retardant test: AS/NZS 1660.5.6
Packing information
1.Max. cable length per drum(m): 1000
2.Drum size(mm): 1120 x 630 x 1120
3.Gross weight per drum(kg): 530
4.No. of drums: 1
Contact Information Customer Approved by
Address: 27 Senoko way
Singapore 758060
Tel: (65) 6367 0107
Fax: (65) 6365 2963
Email: sales@keystone-cable.com
Website: www.keystone-cable.com
Spec.No Prepared by Checked by Approved by
S-130617-08C SongKunhua YuLei Patrick Li
NOTE:The information contained in this data sheet is subject to normal manufacturing tolerance, specifications are subject to change without notice.
SPECIFICATION
SIEMENS MTO ITEM No.: F3
CONTROL CABLE: 6C X 2.5 mm2
CU/XLPE/PVC,Unarmoured
Cross Drawing

Description

Application:This cable is designed for areas where the integrity of the


electrical circuit is critical in maintaininig power supply applications can be
found in emergency lighting,control and power stations,fire alarm systems,
underground tunnels and so on.

Rated Voltage(V): 450/750


Rated Temperature(℃): 90
Generally refer to specification: AS/NZS 5000.3、AS/NZS 1125
AS/NZS 3808、AS/NZS 1660
IEC 60332-3-22
Cable Construction Color

No. of Cores 6 Insulation: White with black numbering


Conductor
Material: Plain annealed copper wire
Cross-Sectional Area(mm2): 2.5 Outer sheath: Black(UV-Stabilised)
Approx. Conductor Dia.(mm): 2.01
Class of Conductor: Class 2 Performance
Insulation Electrical characteristics
Material: XLPE(X-90) 1.Max. Conductor D.C. resistance at 20℃(Ω/km): 7.41
Nom. Thickness(mm): 0.6 2.Min. Insulation Resistance at 20℃(MΩ•km): 1000
Approx. Dia. over insulation(mm): 3.3 3.Spark test A.C. voltage value(kV): 6
Outer Sheath 4.A.C. high voltage test for 5min(kV): 2.5
Material: PVC(5V-90)
Nom. Thickness(mm): 1.3
Min. Thickness(mm): 1.01
Approx. Dia. of cable(mm): 14.5
O.D. tolerance(%): ±8 Physical characteristics
Approx. Weight of cable(kg/km): 265.0 1.Min. bending radius(mm)
Order Quantity(m): 2000 a)during installation: 145
b)after installation: 116
2.Max. pulling tension for conductor(kN): 1.050
3.Construction test: AS/NZS 5000.3
4.Flame retardant test: IEC 60332-3-22

Packing information
1.Max. length per drum(m): 2000
2.Drum size(H x W x L)(mm): 1250 x 710 x 1250
3.Gross weight per drum(kg): 610
4.No. of drums: 1

Contact Information Customer Approved by


Address: 27 Senoko way
Singapore 758060
Tel: (65) 6367 0107
Fax: (65) 6365 2963
Email: sales@keystone-cable.com
Website: www.keystone-cable.com
Spec.No Prepared by Checked by Approved by
S-130617-09C SongKunhua YuLei Patrick Li
NOTE:The information contained in this data sheet is subject to normal manufacturing tolerance, specifications are subject to change without notice.
SPECIFICATION
SIEMENS MTO ITEM No.: F45
CONTROL CABLE: 2C X 2.5 + E 2.5 mm2
CU/XLPE/PVC,Unarmoured
Cross Drawing

Description

Application:This cable is designed for areas where the integrity of the


electrical circuit is critical in maintaininig power supply applications can be
found in emergency lighting,control and power stations,fire alarm systems,
underground tunnels and so on.

Rated Voltage(V): 450/750


Rated Temperature(℃): 90
Generally refer to specification: AS/NZS 5000.3、AS/NZS 1125
AS/NZS 3808、AS/NZS 1660
IEC 60332-3-22
Cable Construction Color
Active cores Earth core
No. of Cores 2 1 Insulation: White with black numbering(1~2) + Green/yellow
Conductor
Material: Plain annealed copper wire
Cross-Sectional Area(mm2): 2.5 2.5 Outer sheath: Black(UV-Stabilised)
Approx. Conductor Dia.(mm): 2.01 2.01
Class of Conductor: Class 2 Performance
Insulation Electrical characteristics
Material: XLPE(X-90) Active cores Earth core
Nom. Thickness(mm): 0.6 1.Max. Conductor D.C. resistance at 20℃(Ω/km): 7.41
Approx. Dia. over insulation(mm): 3.3 2.Min. Insulation Resistance at 20℃(MΩ•km): 1000
Outer Sheath 3.Spark test A.C. voltage value(kV): 6
Material: PVC(5V-90) 4.A.C. high voltage test for 5min(kV): 2.5
Nom. Thickness(mm): 1.3
Min. Thickness(mm): 1.01
Approx. Dia. of cable(mm): 11.3
O.D. tolerance(%): ±8 Physical characteristics
Approx. Weight of cable(kg/km): 155.0 1.Min. bending radius(mm)
Order Quantity(m): 9000 a)during installation: 113
b)after installation: 90
2.Max. pulling tension for conductor(kN): 0.525
3.Construction test: AS/NZS 5000.3
4.Flame retardant test: IEC 60332-3-22

Packing information
1.Max. length per drum(m): 3000
2.Drum size(H x W x L)(mm): 1250 x 630 x 1250
3.Gross weight per drum(kg): 440
4.No. of drums: 3

Contact Information Customer Approved by


Address: 27 Senoko way
Singapore 758060
Tel: (65) 6367 0107
Fax: (65) 6365 2963
Email: sales@keystone-cable.com
Website: www.keystone-cable.com
Spec.No Prepared by Checked by Approved by
S-130617-10C SongKunhua YuLei Patrick Li
NOTE:The information contained in this data sheet is subject to normal manufacturing tolerance, specifications are subject to change without notice.
SPECIFICATION
SIEMENS MTO ITEM No.: F42
CONTROL CABLE: 4C X 2.5 + E 2.5 mm2
CU/XLPE/PVC,Unarmoured
Cross Drawing

Description

Application:This cable is designed for areas where the integrity of the


electrical circuit is critical in maintaininig power supply applications can be
found in emergency lighting,control and power stations,fire alarm systems,
underground tunnels and so on.

Rated Voltage(V): 450/750


Rated Temperature(℃): 90
Generally refer to specification: AS/NZS 5000.3、AS/NZS 1125
AS/NZS 3808、AS/NZS 1660
IEC 60332-3-22
Cable Construction Color
Active cores Earth core
No. of Cores 4 1 Insulation: White with black numbering(1~4) + Green/yellow
Conductor
Material: Plain annealed copper wire
Cross-Sectional Area(mm2): 2.5 2.5 Outer sheath: Black(UV-Stabilised)
Approx. Conductor Dia.(mm): 2.01 2.01
Class of Conductor: Class 2 Performance
Insulation Electrical characteristics
Material: XLPE(X-90) Active cores Earth core
Nom. Thickness(mm): 0.6 1.Max. Conductor D.C. resistance at 20℃(Ω/km): 7.41
Approx. Dia. over insulation(mm): 3.3 2.Min. Insulation Resistance at 20℃(MΩ•km): 1000
Outer Sheath 3.Spark test A.C. voltage value(kV): 6
Material: PVC(5V-90) 4.A.C. high voltage test for 5min(kV): 2.5
Nom. Thickness(mm): 1.3
Min. Thickness(mm): 1.01
Approx. Dia. of cable(mm): 13.0
O.D. tolerance(%): ±8 Physical characteristics
Approx. Weight of cable(kg/km): 230.0 1.Min. bending radius(mm)
Order Quantity(m): 2000 a)during installation: 130
b)after installation: 104
2.Max. pulling tension for conductor(kN): 0.875
3.Construction test: AS/NZS 5000.3
4.Flame retardant test: IEC 60332-3-22

Packing information
1.Max. length per drum(m): 2000
2.Drum size(H x W x L)(mm): 1120 x 560 x 1120
3.Gross weight per drum(kg): 540
4.No. of drums: 1

Contact Information Customer Approved by


Address: 27 Senoko way
Singapore 758060
Tel: (65) 6367 0107
Fax: (65) 6365 2963
Email: sales@keystone-cable.com
Website: www.keystone-cable.com
Spec.No Prepared by Checked by Approved by
S-130617-11C SongKunhua YuLei Patrick Li
NOTE:The information contained in this data sheet is subject to normal manufacturing tolerance, specifications are subject to change without notice.
SPECIFICATION
SIEMENS MTO ITEM No.: F43
CONTROL CABLE: 8C X 2.5 + E 2.5 mm2
CU/XLPE/PVC,Unarmoured
Cross Drawing

Description

Application:This cable is designed for areas where the integrity of the


electrical circuit is critical in maintaininig power supply applications can be
found in emergency lighting,control and power stations,fire alarm systems,
underground tunnels and so on.

Rated Voltage(V): 450/750


Rated Temperature(℃): 90
Generally refer to specification: AS/NZS 5000.3、AS/NZS 1125
AS/NZS 3808、AS/NZS 1660
IEC 60332-3-22
Cable Construction Color
Active cores Earth core
No. of Cores 8 1 Insulation: White with black numbering(1~8) + Green/yellow
Conductor
Material: Plain annealed copper wire
Cross-Sectional Area(mm2): 2.5 2.5 Outer sheath: Black(UV-Stabilised)
Approx. Conductor Dia.(mm): 2.01 2.01
Class of Conductor: Class 2 Performance
Insulation Electrical characteristics
Material: XLPE(X-90) Active cores Earth core
Nom. Thickness(mm): 0.6 1.Max. Conductor D.C. resistance at 20℃(Ω/km): 7.41
Approx. Dia. over insulation(mm): 3.3 2.Min. Insulation Resistance at 20℃(MΩ•km): 1000
Outer Sheath 3.Spark test A.C. voltage value(kV): 6
Material: PVC(5V-90) 4.A.C. high voltage test for 5min(kV): 2.5
Nom. Thickness(mm): 1.4
Min. Thickness(mm): 1.09
Approx. Dia. of cable(mm): 16.7
O.D. tolerance(%): ±8 Physical characteristics
Approx. Weight of cable(kg/km): 370.0 1.Min. bending radius(mm)
Order Quantity(m): 7500 a)during installation: 167
b)after installation: 134
2.Max. pulling tension for conductor(kN): 1.575
3.Construction test: AS/NZS 5000.3
4.Flame retardant test: IEC 60332-3-22

Packing information
1.Max. length per drum(m): 2500
2.Drum size(H x W x L)(mm): 1600 x 1000 x 1600
3.Gross weight per drum(kg): 1040
4.No. of drums: 3

Contact Information Customer Approved by


Address: 27 Senoko way
Singapore 758060
Tel: (65) 6367 0107
Fax: (65) 6365 2963
Email: sales@keystone-cable.com
Website: www.keystone-cable.com
Spec.No Prepared by Checked by Approved by
S-130617-12C SongKunhua YuLei Patrick Li
NOTE:The information contained in this data sheet is subject to normal manufacturing tolerance, specifications are subject to change without notice.
SPECIFICATION
SIEMENS MTO ITEM No.: F46
2
INSTRUMENT CABLE:3P X 1.5 mm
CU/XLPE/ISOS/PVC/SWA/PVC,Armoured
Cross Drawing

Description

Application:This cable is used in machines,measuring instrument,and


control systems for the transmission of analogue and digit signals.

Rated Voltage(V): 450/750


Rated Temperature(℃): 90
Generally refer to specification: AS/NZS 5000.3、AS/NZS 1125
AS/NZS 3808、AS/NZS 1660
IEC 60332-3-22
Cable Construction Color
No. of Pairs 3 Insulation: Black、White with numbering
Conductor
Material: Plain annealed copper wire Bedding: Black
Cross-Sectional Area(mm2): 1.5
Approx. Conductor Dia.(mm): 1.59 Outer sheath: Black(UV-Stabilised)
Class of Conductor: Class 2 Performance
Insulation Electrical characteristics
Material: XLPE(X-90) 1.Max. Conductor D.C. resistance at 20℃(Ω/km): 12.3
Nom. Thickness(mm): 0.6 2.Min. Insulation Resistance at 20℃(MΩ•km): 1000
Approx. Dia. over insulation(mm): 2.9 3.Spark test A.C. voltage value(kV): 6
Individual Screen 4.A.C. high voltage test for 1min(kV): 2.0
Material: Al-foil(Al layer inside) 5.Max.Mutual capacitance at 1kHz(nF/km): 150
100% wrapping over the individual pair 6.Max.Inductance to resistance ratio(L/R) (μH/Ω): 40
Drain wire
Material: Tinned copper wire
2 0.5
Cross-Sectional Area(mm ):
Overall Screen
Material: Al-foil(Al layer inside) Physical characteristics
100% wrapping over the binder tape 1.Min. bending radius(mm)
Bedding a)during installation: 252
Material: PVC(5V-90) b)after installation: 210
Nom. Thickness(mm): 1.1 2.Max. pulling tension for conductor(kN): 0.630
Approx. Dia. over bedding(mm): 14.6 3.Construction test: AS/NZS 5000.3
Armour 4.Flame retardant test: IEC 60332-3-22
Material: Galvanized steel wire
Dia. of Armour wire: 0.9
Approx. Dia. over armour(mm): 16.5
Outer Sheath
Material: PVC(5V-90)
Nom. Thickness(mm): 1.5 Packing information
Min. Thickness(mm): 1.00 1.Max. cable length per drum(m): 1500
Approx. Dia. of cable(mm): 21.0 2.Drum size(H x W x L)(mm): 1600 x 1000 x 1600
O.D. tolerance(%): ±8 3.Gross weight per drum(kg): 1090
Approx. weight of cable(kg/km): 650.0 4.No. of drums: 1
Order Quantity(m): 1500
Contact information Customer Approved by
Address 27 Senoko way
Singapore 758060
Tel (65)6367 0107
Fax (65)6365 2963
Email sales@keystone-cable.com
Website www.keystone-cable.com
Spec.No Prepared by Checked by Approved by
S-130617-13C SongKunhua YuLei Patrick Li
NOTE:The information contained in this data sheet is subject to normal manufacturing tolerance, specifications are subject to change without notice.
SPECIFICATION
SIEMENS MTO ITEM No.: H5
CU/PVC Earthing Cable
1C X 70 mm2
Cross Drawing

Description

Application: These cables are intended for use in electrical installations


for earthing purpose

Rated Voltage(V): 600/1000


Rated Temperature(℃): 90
Generally refer to specification: AS/NZS 5000.1、AS/NZS 1125
AS/NZS 3808、AS/NZS 1660.5.6
Cable Construction Color

No. of Cores 1
Conductor
Material: Plain annealed copper wire Insulation: Green/yellow
2 70
Cross-Sectional Area(mm ):
Approx. Conductor Dia.(mm): 9.8
Class of Conductor: Class 2
Insulation Performance
Material: PVC(V-90) Electrical characteristics
Nom. Thickness(mm): 1.4 1.Max. Conductor D.C. resistance at 20℃(Ω/km): 0.268
Min. Thickness(mm): 1.16 2.Min. Insulation Resistance at 20℃(MΩ•km): 10
Approx. Dia. of cable(mm): 12.8 3.Spark test A.C. voltage value(kV): 10
Approx. weight of cable(kg/km): 700.0 4.A.C. high voltage test for 5min(kV): 2.5
Order Quantity(m): 500

Physical characteristics
1.Min. bending radius(mm)
a)during installation: 128
b)after installation: 102
2.Max. pulling tension for conductor(kN): 4.900
3.Construction test: AS/NZS 5000.1
4.Flame retardant test: AS/NZS 1660.5.6

Packing information
1.Max. cable length per drum(m): 500
2.Drum size(mm): 800 x 400 x 800
3.Gross weight per drum(kg): 420
4.No. of drums: 1

Contact Information Customer Approved by


Address: 27 Senoko way
Singapore 758060
Tel: (65) 6367 0107
Fax: (65) 6365 2963
Email: sales@keystone-cable.com
Website: www.keystone-cable.com
Spec.No Prepared by Checked by Approved by
S-130617-14B SongKunhua YuLei Patrick Li
NOTE:The information contained in this data sheet is subject to normal manufacturing tolerance, specifications are subject to change without notice.
SPECIFICATION
SIEMENS MTO ITEM No.: D13
INSTRUMENT CABLE:1T X 1.5 mm2
CU/MT/XLPE/OS/LSZH/SWA/LSZH,Armoured
Cross Drawing

Description

Application:This cable is used in machines,measuring instrument,and


control systems for the transmission of analogue and digit signals.

Rated Voltage(V): 450/750


Rated Temperature(℃): 90
Generally refer to specification: AS/NZS 5000.3、AS/NZS 1125
AS/NZS 3808、AS/NZS 1660
IEC 60331、IEC 60332-3-22
Cable Construction Color
No. of Triads 1 Insulation: Red、Black、White
Conductor
Material: Plain annealed copper wire Bedding: Black
Cross-Sectional Area(mm2): 1.5
Approx. Conductor Dia.(mm): 1.59 Outer sheath: Red(UV-Stabilised)
Class of Conductor: Class 2
Fire Barrier Tape Performance
Material: Mica Tape Electrical characteristics
100% wrapping over the conductor 1.Max. Conductor D.C. resistance at 20℃(Ω/km): 12.1
Insulation 2.Min. Insulation Resistance at 20℃(MΩ•km): 1000
Material: XLPE 3.Spark test A.C. voltage value(kV): 6
Nom. Thickness(mm): 0.6 4.A.C. high voltage test for 1min(kV): 2.0
Approx. Dia. over insulation(mm): 3.7 5.Max.Mutual capacitance at 1kHz(nF/km): 150
Drain wire 6.Max.Inductance to resistance ratio(L/R) (μH/Ω): 40
Material: Tinned copper wire
Cross-Sectional Area(mm2): 0.5
Binder tape
Material: Mylar-tape
100% wrapping over the assembly Physical characteristics
Overall Screen 1.Min. bending radius(mm)
Material: Al-foil(Al layer inside) a)during installation: 204
100% wrapping over the binder tape b)after installation: 170
Bedding 2.Max. pulling tension for conductor(kN): 0.315
Material: LSZH 3.Construction test: AS/NZS 5000.3
Nom. Thickness(mm): 0.9 4.Fire resistant test: IEC 60331
Approx. Dia. over bedding(mm): 11.4 5.Flame retardant test: IEC 60332-3-22
Armour 6.Min. Oxygen index: 30
Material of Armour: Galvanized steel wire
Dia. of Armour wire: 0.9
Approx. Dia. over armour(mm): 13.2
Outer Sheath Packing information
Material: LSZH 1.Max. length per drum(m): 1200
Nom. Thickness(mm): 1.3 2.Drum size(H x W x L)(mm): 1120 x 560 x 1120
Min. Thickness(mm): 0.84 3.Gross weight per drum(kg): 650
Approx. Dia. of cable(mm): 17.0 4.No. of drums: 1
O.D. tolerance(%): ±8
Approx. weight of cable(kg/km): 470.0
Order Quantity(m): 1200
Contact information Customer Approved by
Address 27 Senoko way
Singapore 758060
Tel (65)6367 0107
Fax (65)6365 2963
Email sales@keystone-cable.com
Website www.keystone-cable.com
Spec.No Prepared by Checked by Approved by
S-130621-15B SongKunhua YuLei Patrick Li
NOTE:The information contained in this data sheet is subject to normal manufacturing tolerance, specifications are subject to change without notice.
SPECIFICATION
SIEMENS MTO ITEM No.: E2
INSTRUMENT CABLE:2P X 1.5 mm2
CU/MT/XLPE/ISOS/LSZH/SWA/LSZH,Armoured
Cross Drawing

Description

Application:This cable is used in machines,measuring instrument,and


control systems for the transmission of analogue and digit signals.

Rated Voltage(V): 450/750


Rated Temperature(℃): 90
Generally refer to specification: AS/NZS 5000.3、AS/NZS 1125
AS/NZS 3808、AS/NZS 1660
IEC 60331、IEC 60332-3-22
Cable Construction Color
No. of Pairs 2 Insulation: Black、White with numbering
Conductor
Material: Plain annealed copper wire Bedding: Black
Cross-Sectional Area(mm2): 1.5
Approx. Conductor Dia.(mm): 1.59 Outer sheath: Red(UV-Stabilised)
Class of Conductor: Class 2 Performance
Fire Barrier Tape Electrical characteristics
Material: Mica Tape 1.Max. Conductor D.C. resistance at 20℃(Ω/km): 12.3
100% wrapping over the conductor 2.Min. Insulation Resistance at 20℃(MΩ•km): 1000
Insulation 3.Spark test A.C. voltage value(kV): 6
Material: XLPE 4.A.C. high voltage test for 1min(kV): 2.0
Nom. Thickness(mm): 0.6 5.Max.Mutual capacitance at 1kHz(nF/km): 150
Approx. Dia. over insulation(mm): 3.7 6.Max.Inductance to resistance ratio(L/R) (μH/Ω): 40
Individual Screen
Material: Al-foil(Al layer inside)
100% wrapping over the individual pair
Drain wire
Material: Tinned copper wire
Cross-Sectional Area(mm2): 0.5 Physical characteristics
Overall Screen 1.Min. bending radius(mm)
Material: Al-foil(Al layer inside) a)during installation: 289
100% wrapping over the binder tape b)after installation: 241
Bedding 2.Max. pulling tension for conductor(kN): 0.420
Material: LSZH 3.Construction test: AS/NZS 5000.3
Nom. Thickness(mm): 1.1 4.Fire resistant test: IEC 60331
Approx. Dia. over bedding(mm): 17.7 5.Flame retardant test: IEC 60332-3-22
Armour 6.Min. Oxygen index: 30
Material: Galvanized steel wire
Dia. of Armour wire: 1.25
Approx. Dia. over braid(mm): 20.2
Outer Sheath
Material: LSZH Packing information
Nom. Thickness(mm): 1.5 1.Max. cable length per drum(m): 1200
Min. Thickness(mm): 1.00 2.Drum size(H x W x L)(mm): 1600 x 1000 x 1600
Approx. Dia. of cable(mm): 24.1 3.Gross weight per drum(kg): 1210
O.D. tolerance(%): ±8 4.No. of drums: 1
Approx. weight of cable(kg/km): 900.0
Order Quantity(m): 1200
Contact information Customer Approved by
Address 27 Senoko way
Singapore 758060
Tel (65)6367 0107
Fax (65)6365 2963
Email sales@keystone-cable.com
Website www.keystone-cable.com
Spec.No Prepared by Checked by Approved by
S-130621-02B SongKunhua YuLei Patrick Li
NOTE:The information contained in this data sheet is subject to normal manufacturing tolerance, specifications are subject to change without notice.

Potrebbero piacerti anche