Product: High Strength Friction Grip Fasteners For Structurals (Property class Bolt 8.8, 10.9/Nut 8, 10)
Revision record:
Rev 00: Fresh Issue
1. SCOPE:
This technical delivery condition covers the requirements for the High strength structural steel bolts, Nuts and Washers
applicable for boiler structures. The product shall conform to the mandatory requirements, test methods and procedures as called
for in the applicable standards. The requirements stated herein are in addition to material specification requirements.
Size, Specification and Quantity: As per the BHEL Purchase order (PO) / BHEL Drawing. The bolts, nuts and washers
shall be supplied in the dull black heat treated condition with residual coating of light oil.
For Bolts: EN: 14399-3 (Latest) Property class: 8.8 or 10.9 & EN ISO 898 -1 for Mechanical properties.
For Nuts: EN 14399-3 (Latest) Property Class: 8 or 10, Regular nut Style 1, Coarse thread & EN ISO 898 -2 for Mechanical
properues
For Washers: EN: 14399-5 (Latest)
2. RAW MATERIAL:
• Chemical composition: Shall be checked on receipt of raw material at supplier works for every heat/cast. In case of
disputes, product analysis applies.
Bolts: Carbon steel with additives (eg B, Mn or Cr)— As per Table 2 of ISO 898 -1 (Latest)
Nuts: Carbon steel as per Table .3 of ISO 898 -2 (Latest)
Washers: Steel as per EN: 14399-5 (I...atest)
BOLT:
Mechanical:
• The mechanical and physical properties shall be according to Tables 3 to 7 of EN: 14399-3 for the respective property
class
• Bolts shall be tested for the series FF1 and MP2 for full loadability, using the test methods described in Clause 9 EN ISO
898 -1.
• Bolts shall be subject CO the f1dlowing tests:
o Hardness test
o Strength under wedge load test (if wedge load test is satisfactory, axial tensile test is not required)
o Minimum Tensile Strength
o Proof load test
o Decarbunzatum test
o Hardness after Re-Tempering (test not mandatory, to be applied in case of dispute only)
BHEL — Tiruchirappalli - 620014, India. DOC No: TDC : 6 : 388 Rev: 00
Quality Assurance Department Effective Date: 29/117/2017
TECHNICAL DELIVERY CONDITIONS Page: 2 of 3
Produce High Strength Friction Grip Fasteners For Structurals (Property class Bolt 8.8, 10.9/Nut 8, 10)
NDE:
• Surface Quality shall meet the requirements of ISO 6157-1
NUT :
Mechanical:
• The mechanical and physical properties shall be according to Tables 4 and 6 of EN: 14399-3 and to be tested using methials
described in Clause 9 EN ISO 898 -2.
• Nuts shall be subject to the following tests:
o Hardness test
o Proof Load test
NDE:
• Surface Quality' shall meet the requirements of ISO 6157-2
WASHERS :
• I lardness range 30011V to 370HV.
1) Purchase Order No.(BHEL), TDC No, Specification and Grade with year of code.
2) Name of raw material bar supplier.
3) Forming process
4) Dimensional reports for each product.
5) Chemistry including incidental elements.
6) HT details of materials temperature, soaking time, cooling medium etc.
7) All Mechanical test result report including hardness.
8) MPI, Micro examination and decarburizadon test report with the reference & acceptance andard
9) TC of raw material shall accompany the MTC.
8. AUDITS BY BHEL:
BHEL reserves the right to reject any item found to be not meeting the requirements during tests at supplier works or during
subsequent processing at BHEL.
Quality Assurance DOC No. TDC : : 388 / Rev: 00
BHEL - Tiruchirappalli - 620014, India.
TECHNICAL DELIVERY CONDITIONS j Effective Date 29/117/201'
Department
Pac: 3 of 3
Product: High Strength Friction Grip Fasteners For Structurals (Property class Bolt 8.8, 10.9/Nut 8, 10)
PROJECT: MAITREE (2x660 MW)
GUST: 1725 & 1726
9. SAMPLING PLAN:
JAMr 1...r. .a.........
Acceptance P Ideal Tests
S"ngle Number/ Remarks
Size Wedge Mn
Lot Size Rej ection hardness 2 ftet Re- Proof Load Ten"ic Decarburetation
(as per Visual Dimensional ND1'. I la rdness
S.No. Number, tempering (no.) Load (nos) Strength
S02859- (Nos.) (Nos)
(Ac/Re) (Nr''' $ 5
1) (005)S (nos.) $
(kAQ L = P/s nos.) (nos.)
5
11pto
15 0/1 1 ic ts- 5 5
280 5 5 5
20 20 20
281-500 20 0/1 26 4
2 5 5
32 5 5
501- 32 32 32 32
32 1/2
1200 3
. 1 50 5 5 5
1201- 50 30 I 50 For tcsts
50 1/2
3200 10 arked
80 10 10 10
80 80 80 ugh 1',
to 2/3 11:11 i
1(1 10 Ac/Re--0
125 10 10
10001 ro 3/4 125 125 125 125
125
35000 10
10 10 10
35001 to 200 200 200 200
200 5/6 200
150000
150001 1111 10 10 10
315 315 10
7/8 315 315
to
8 500000 10 10 10
30
9 >500000 30 0 EMI 500
500 500
W W W
Inspection by W w
$11.1EL/131-1EL AM
BHEL / BHEL Ala shown as 'W" shall be witnessed to the sample size indicated against the lot size.
Note: Inspection by
Revisankaran
21101'
Abdo,. R S Panneer SCIV2ITI G nma Kumar N Morotpn Dhannar R Naraytmun R
SIX;MIMM AC:NI/Q.\ & BE
M Jeyaram :MG M/ P1 r.(i ,11) ACM/QC
DGM g A 1)1 ;10/QA Approved By
1h. Mgr/QA Sr. Engr/QA
Rolcwed BY
Prepared By