FLSmidth®
Cross-Bar® cooler
The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
NO. OF CROSS-BAR COOLERS
FLSmidth® 40
Cross-Bar® 30
20
Total installed capacity
cooler 10
0
~500
< 3000 3000-5999 6000-8999 > 9000 million tons
Capacity (TPD) clinker per year
350 38
Cross-Bar type coolers coolers in the size range
sold since 1997 6.000-12.000 tpd
4 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
FLSmidth®
Cross-Bar® cooler
Key Features
5 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
FLSmidth® Cross-Bar® cooler animation
6 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
ENERGY AVAILABILITY
FLSmidth®
Cross-Bar®
cooler
Consistent and high High reliability /
thermal efficiency availability
7 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
Consistent and
high thermal efficiency
8 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
Separate clinker conveying
and air distribution systems
The gradual wear on the bars elements has
Air no impact on thermal efficiency or operation
distribution
system
9 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
Separate clinker conveying
and air distribution systems
Cross-Bar® cooler Grate cooler
Fixed grate line, Cross bars convey clinker Moving grates, Grate plates convey clinker
Wear only on Cross bars, it does not affect Grate plate wears gradually
cooling efficiency Inefficient cooling air via gaps
High and consistent thermal efficiency Reduced thermal efficiency,
Higher fuel consumption
Increased clinker exit temperature
10 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
Self-adjusting Mechanical Flow Regulator (MFR)
and low pressure drop air distribution plate
Limiting airflow to clinker bed, irrespective
of conditions above the grate line
Air through
holes in
Air through tongue
gaps
11 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
Typical heat and mass balance
Clinker cooler
Cooler Efficiency: 77,0 %
Tertiary air
with combustion air: 1.10 kg/kg cl. and ambient temp. 30 °C
0.650 kg/kg cl.
968 °C
Excess air Mid air 166.6 kcal/kg cl.
1.20 kg/kg cl. 0.0 kg/kg cl.
313 °C Secondary air
93.5 kcal/kg cl. 0.450 kg/kg cl.
1068 °C
Radiation 128.4 kcal/kg cl.
4.0 kcal/kg cl.
Clinker
Clinker
1.0 kg/kg cl.
1.0 kg/kg cl.
1450 °C
95 °C
383.0 kcal/kg cl.
17.7 kcal/kg cl.
Cooler thermal efficiency
Cooling air η = Hsec air + Hter air
2.30 kg/kg cl. Hclinker 1450°C
30 °C (ambient) η = (128.4 + 166.6) / 383.0
16.8 kcal/kg cl.
*reference to 0 °C
η = 77,0 %
12 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
Results achieved after Cross-Bar® cooler upgrade
at Rain Cement Ltd., India
Before After
Cross-Bar cooler
Cooler type Walchandnagar cooler
CB 10x41
13 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
Results achieved after Cross-Bar®
cooler upgrade in India
Before After
FLSmidth Cross-Bar
Cooler type Fons delta
CB 14x60
Maintenance year 2013 - 2014 2016 - 2017 “Mechanical wear and tear
got reduced when compared
Maintenance cost 0.062 $/t 0.006 $/t to the previous cooler. Heat
recuperation efficiency also
increased”
14 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
Results achieved after Cross-Bar® cooler upgrade
in China
Before After
15 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
Results achieved after Cross-Bar® cooler upgrade
at Jiangsu Helin Cement Co. Ltd., China
Before After
16 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
High reliability /
availability
17 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
FLSmidth® ABC™ inlet (Air Blast Controlled)
18 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
ABC™ inlet grate with internal valve
Blast air
when required
Normal
cooling air Blast air can reach
through MFR entire fixed inlet area
19 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
Other supplier’s Fixed inlet
- air blaster arrangement
Side/back wall blaster
reach only 0.5m, can’t
reach the entire inlet zone
Ineffective in eradicating
Back walls
the root cause for
agglomeration over grates
Snowman formation exists
Ineffective blasting
Side Side
walls Blast air does not reach walls
these fixed inlet area
20 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
ABC™ inlet - proven design
ABC™ inlet
21 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
Results achieved after ABC™ inlet upgrade
at Titan Pennsuco, Florida, USA
Before After
1/shift
Snowmen 0
(removed with water jet)
22 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
Protected stationary grate line
Static grate carrying the weight of the clinker Static clinker layer between bar and grate
23 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
Sealed grate line
Proven seal design, 20+ years experience No under grate spillage removal system
24 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
Horizontal design with
optimised transport method
Adjustable stroke
length of each drive
eliminate red rivers
25 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
Horizontal design with
optimised transport method
Shuttle motion with Cross-Bar® cooler
independent, finite
control across the
cooler width
Grate cooler
Red river Red river
Drive 1
Stroke length 130
26 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
Red river control
1450 °C
1250 °C
1100 °C
900 °C
700 °C
Grate cooler
500 °C
350 °C
200 °C
150 °C
90 °C
Cross-Bar® cooler
27 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
Heavy-duty Roll Breaker
highest reliability
Crush very large lumps without stopping the
cooler
28 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
Cases:
High cooler reliability achieved
RELIABILITY FACTOR [%] >99.5%
99,94 99,97 99,90 99,93 99,96 99,97 99,96 100,00 99,94 100,00 99,78 99,80 99,93 99,88 99,93
100,00 99,60 99,84 99,55
99,00
98,00
97,00
96,00
95,00
94,00
93,00
92,00
91,00
90,00
2011 2012 2013 2014 2015 2016
29 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
Waste Heat Recovery with hot air recirculation
Flexibility in the location of hydraulic cylinders
Secondary +
Tertiary air
Mid air / WHR
Vent air
30 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
Fast, low cost
installation
31 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
Workshop pre-assembly and
container transport
32 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
Retrofit - less than 30 days
33 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
Low, predictable
maintenance
34 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
Low, predictable maintenance
35 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
First installation of FLSmidth® Cross-Bar® cooler
at Capitol, Texas, USA
8-grate wide rated for 2000 t/d
36 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
Actual wear part consumption
at Capitol, Texas, USA
Approx 0,006
USD/T Clinker over 5 years
Newly installed After 5 years in operation
37 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
Results achieved after Cross-Bar®
cooler upgrade at Capitol, Texas, USA
Before After
> 900°C
< 700°C
Tertiary air temperature (common kiln hood) while
(separate take-off)
maintaining air temperature …and no unplanned kiln
outages to date since start-
Fan power consumption High Reduced (-20%) up in April 2010
38 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
The latest generation in
Cross-Bar® cooler technology
Resulting Benefits
39 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
Cooler Optimization Support
1 process audit every year for 3 years after commissioning
FLSmidth® supports beyond the first
start-up
Optimized performance
40 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
Recent
improvements on
Cross-Bar® cooler
41 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
ABC™ inlet updates
42 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
First cross bar
Old Present
43 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
Updated cast parts and drive plate
44 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
Updated & increased number of
Thermocouples units
Elevated to ensure measurement in active bed
Ensures early detection of high clinker bed temperature
Monitors each lane, near first pusher phase
Facilitates continued kiln operation even when one drive is hot and stopped
90 mm
35 mm
Old Present
45 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
Cooler interlock updates
46 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
Simplified Hydraulic system
47 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
16 October 2018
The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
SF™ Cross-Bar® cooler upgrade
Potential benefits:
49 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
How is higher transport efficiency
achieved in the SF™ Cross-Bar® cooler upgrade?
Movable bars
One movable and one stationary bar All bars are movable
Each bar covers the width of 4 grates (1.2 m) Each bar covers the width of 2 grates (0.6 m)
Less transport efficiency of clinker Higher transport efficiency
Reduced cooler speed
Life of wear parts extended by 30 to 50%
50 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
SF™
Cross-Bar®
cooler
upgrade
51 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
First SF™ Cross-Bar® cooler upgrade project
Ramliya cement plant, Egypt
Arabian Cement Co., Ramliya I plant, Egypt
Cooler: SF 4x6
52 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
First SF™ Cross-Bar® cooler upgrade project (2010)
Ramliya cement plant, Egypt
Before upgrade 6150 tpd (22 spm) After upgrade +6800 tpd (12 spm)
53 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
Tasks in SF™ Cross-Bar® cooler upgrade
on an already installed SF cooler
Replacement of bars with a new design Installation of required hydraulic piping
Mount new grate protection plates New PLC program and supplementary
electrical parts are needed
Divide the drive frame in two drive plates
(dismantling of the connections between Upgrade on installed SF Cross-Bar
drive plates and original cylinder bracket) cooler can be completed in about 2-3
weeks period, or the above tasks can
Replacement of cylinder brackets and inter- integrated during manufacturing before
modular straps cooler installation
Installation of hydraulic blocks for flow
dividers and directional valves
(existing hydraulic cylinders reused)
54 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law
Thank you
flsmidth.com/linkedin
flsmidth.com/twitter
flsmidth.com/facebook
flsmidth.com/instagram
flsmidth.com/youtube
55 16 October 2018 FLSmidth® Cross-Bar® cooler The information contained or referenced in this presentation is proprietary to FLSmidth and is protected by copyright law