Important notice:
Not smoothed 24 V DC is used for signalization on D-type
D type controller. This voltage is suitable for power
supply of SEC indicators as well. Indicators and similar devices
evices from other manufacturers usually need
more stabilized voltage and so an additional
a interface,
rface, shown on the drawing bellow, shall be used.
Example 1:
P19=2, P96=0 – lift will make 10,000 normal starts, after that its operation will be reduced.
Example 2:
P19=31, P96=1 – lift will work 30 days normal, after that its operation will be reduced.
304 305
SKV – car door switch
SKV PHK – car floor switch (occupied)
PHK
Not for use in the EU.
73
Example 2:
P19=31, P96=1 – lift will work (P19 – 1) * 3 = 90 days normal, after that its operation will be
reduced.
__________________________________________________________________________________
42 UPS drive
Lift is switched to Uninterruptable Power Supply (UPS) after power failure. This function is possible
only when P30 is set to 1 and P32 is set to 4 or 5 and works as follows:
- UPS drive is activated with terminal 66 Slow speed down / UPS. When this terminal is switched on
during travel, all outputs are disabled for 5 seconds.
- After 5 seconds, lift is started normally and travels to the next station in up or down direction.
When station is reached, doors are operating normally, but calls are not accepted. Both direction
outputs are on during UPS drive!
- UPS drive is controlled by P19 Travel time – test speed timer.
- If UPS drive is activated when lift is in station, doors are operating normally, but calls are not
accepted and lift remains in station.
- When mains supply is back again (Slow speed down / UPS input is switched off) lift goes to the
first drive.
- Maintenance drive in UPS mode works only when both keys (up and down) are pressed. Car
moves always in ‘easy’ direction – empty car up, fully loaded car down.
Lift stops from maintenance speed following the deceleration ramp when both, maintenance up and
down, buttons are pressed. This way lift can be stopped softly when traveling in maintenance mode.
2 - Hydraulic type A – hydraulic pump is switched off after valves on travel UP; delay time is defined
in parameter P14; P90 shall be set to 0.
Output Function Note
RE4 Hydraulic pump contactor Switched on Star delta time (P13) before travel up relay
control (RE2).
Switched off Pump delay time (P14) after RE2.
RE5 Hydraulic pump delta Switched on together with travel up relay (RE2).
Switched off Pump delay time (P14) after RE2.
4 - Hydraulic type C – valves are switched off after hydraulic pump on travel up; time of delay is
defined in parameter P14 (delay time); P90 shall be set to 0.
Output Function Note
RE4 Hydraulic pump contactor Switched on Star delta time (P13) before travel up relay
control (RE2).
Switched off with RE2.
RE5 Hydraulic pump delta Activated when travel up relay (RE2) is on.
2 - Hydraulic type E – electronically controlled valves with an additional safety valve according to
EN81-2-A3; P90 shall be set to 1.
Output Function Note
RE4 Hydraulic pump contactor Switched on Star delta time (P13) before travel relays
and safety valve (RE1, RE2).
Switched off Pump delay time (P14) after RE1 or RE2.
Activated also when lift waits in station with open
doors.
RE5 Hydraulic pump delta and Switched on 300 ms before travel up relay (RE2).
valve up Switched off Pump delay time (P14) after RE2.
RE6 Hydraulic pump star Switched on together with RE4.
Switched off 120 ms before RE5 is activated.
RE1 Travel down Activated during travel down, deactivated when car
comes to station (all 4 switches active, both zone and
both re-leveling).
RE2 Travel up Activated during travel up, deactivated when car comes
to station (all 4 switches active, both zone and both re-
leveling).
RE3 High (nominal) speed
Terminal Valve down Switched on 300 ms before travel down relay (RE1).
107 Switched off Pump delay time (P14) after RE1.
42 UPS drive
Lift is switched to Uninterruptable Power Supply (UPS) after power failure. This function has two
options, VVVF (P30=1) and hydraulic type E (P30=2, P90=1).
VVVF:
- Function is possible only when P30 = 1 and P32 = 4 or 5.
- UPS drive is activated with terminal 66 (Slow speed down / UPS) on D-type module. When this
terminal is switched on during travel, all outputs are disabled for 5 seconds.
- After 5 seconds, lift is started normally and travels to the next station in up or down direction.
When station is reached, doors are operating normal, but calls are not accepted. Both direction
outputs (RE1 and RE2) are on during UPS drive!
- UPS drive is controlled by P19 Travel time – test speed timer.
- If UPS drive is activated when lift is in station, doors are operating normally, but calls are not
accepted and lift remains in station.
- When mains supply is back again (Slow speed down / UPS input is switched off) lift continues with
normal operation. If the lift was travelling during UPS mode, it goes to the first drive and then
continues with normal operation.
- Maintenance drive in UPS mode works only when both keys (up and down) are pressed. Car
moves always in ‘easy’ direction – empty car up, fully loaded car down.
66 slow speed down switch / UPS; UPS function is active only with the following three parameter
combinations:
P30 = 1, P32 = 4;
P30 = 1, P32 = 5;
P90 = 1