Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
0.75Lx
Ly
0.75Ly
Lx
Lx
Bottom Reinforcements- Typical for all floors Top Reinforcements- Typical for all floors
12D@8" C/C. Refer Slab Typical Details for Curtailment
length
3-12D@8" EW
2-12D@8" EW 2-12D@8" EW
3-12D@8" EW 4-12D@8" EW 3-12D@8" EW
2-12D@8" EW
3-12D@8" EW 2-12D@8" EW 2-12D@8" EW
3-12D@8" EW 4-12D@8" EW
2-12D@8" EW
3-12D@8" EW 2-12D@8" EW
2-12D@8" EW
3-12D@8" EW
4-12D@8" EW
2-12D@8" EW
12D@8" C/C
0.3Ly
3-12D@8" EW
2-12D@8" EW
3-12D@8" EW 4-12D@8" EW
Note: 4-12D@8" EW indicates- Four nos. of 12 mm diameter rebar placed uniformly to either side of the column at 8 Inch center to center in each direction
(EW= Each Way)
Rebar length shall be as per the Typical details in S003/01
Beam Top
Reinforcement
Beam Depth
Slab Bottom Reinforcement
5"
10@5 'C/C
10@6" C/C
Figure: Typical Details at slope overhang
10D@6" C/C
Ld Ld
10@5 'C/C
20 "
10@6" C/C
Note: Typical Sloping Roof Details; Similar to existing details with 10D@ 6"
Figure: Typical Column details at roof level
0.3L
LD
Bd
5"
Bw