AC’s CHECKLIST IN DESIGN EVALUATION REPORT

Project Title: GEYLANG C26A - PROPOSED PUBLIC HOUSING DEVELOPMENT


COMPRISING 6 BLOCKS OF 6 / 10 / 19 - STOREY RESIDENTIAL BUILDINGS (TOTAL
742 UNITS) WITH MULTI - STOREY CAR PARK, ESS, PRECINCT PAVILION &
COMMERCIAL / COMMUNITY FACILITIES AT EUNOS ROAD 2 / EUNOS AVENUE 5

Project Reference No: A1812-00003-2017-ST

Name of AC: Ho Chong Leong

Name of PE assisting AC: Dr Vincent Zhang

Highest Qualification / Name of Total years of


Name of engineers assisting AC
University design experience
B.Eng (Civil) / Nanyang
Eddy Woo Technological University 10 years

PART A:- OVERALL DESIGN REVIEW TASKS

For the design check on the building or structures in this submission, I confirm that I have
evaluated, analyzed and reviewed the foundation and structural design with a view to
determining their structural adequacy. Besides other tasks, I have specifically performed the
following tasks and have found that the building or structures designed are structurally
adequate and safe:-

(I) Codes Of Practice

-used appropriate codes for the design check

(II) Design Loadings

-checked that loadings used in design are appropriate and adequate

-used appropriate load combinations to check the design

(III) Structural Analysis

-used appropriate engineering information and models in the analysis

-ascertained the design assumptions and limitations of the computer programs used
which preferably should be different from that used by the design QP

BEV/A3 Page 1 of 12
[Ver 3.0_Dec_2014]
(IV) Stability & Robustness

-determined the stability and robustness of the structural system, including


considerations for lateral loads, lateral ties, bracings and lateral transfer of loads

(V) All Key Structural Elements

-analysed and checked the design of all key structural elements and the foundation
system

(VI) Structural Drawings

-checked that the detailings in drawings of all key structural elements are adequate
and consistent with the intentions in design calculations

(VII) Other Aspects in Design

-determined the adequacy of other aspects of design which are peculiar to the building
to be constructed or affected by the building works and which are essential to the
structural integrity of the building

Part B: - FOUNDATION & STRUCTURAL ELEMENTS

For the following foundation and structural elements or structures, besides other engineering
considerations made by me, I have specifically carried out all the tasks as described in the
table below and confirmed that their designs are structurally adequate and safe: -

BEV/A3 Page 2 of 12
[Ver 3.0_Dec_2014]
(I) Foundation

Please tick one: Applicable Not Applicable

Foundation Specific Design Tasks Carried Out Applicable (√ ) /


Not Applicable (X)
• Appropriate values of dead, live ,wind and notional loads
(X)
have been used

• Column loads have been appropriately computed (X)


Foundation
loads
• Effects of wind and notional loads on the building or
(X)
structure have been checked

• Comparison of the loading computation by the QP &


(X)
AC has been carried out

• Piles have been designed for skin friction and end


bearing capacities (X)

• Piles have been designed for lateral loads and bending


moment (X)

• Pile joints have been designed for (X)


Piles
• Piles have been designed for uplift (X)

• Socketings have been designed for piles with short


penetration depths (X)

• Piles have been designed for negative skin friction (X)

• Appropriate allowable bearing capacity of soil has been (X)


assumed in design
• Appropriate modulus of sub-grade reaction of the soil (X)
has been assumed in design
(X)
Raft • Appropriate model used for structural analysis of the raft

• The raft has been designed to resist punching shear from (X)
columns
(X)
• The building or structure has been designed to cater for
probable differential and total settlement.

BEV/A3 Page 3 of 12
[Ver 3.0_Dec_2014]
(II) Building / Structural Systems

(a) Building of less than 30 Storeys

Please tick one: Applicable Not Applicable

Applicable (√ ) /
Items Specific Design Tasks Carried Out Not Applicable (X)

(i) Designed for wind loads (X)

(ii) Designed for notional loads (√)


Stability system has been identified and evaluated to be adequate
(iii) (X)
and robust

Designed corewalls and columns to resist lateral loads due to wind (√)
(iv)
and notional loads in both directions

(v) Provided adequate internal and peripheral ties at floor levels (√)

Designed for capacities to resist base overturning moment and (X)


(vi)
base shear

(vii) Designed for building sway (p-delta effect) (X)

BEV/A3 Page 4 of 12
[Ver 3.0_Dec_2014]
(b) Building of 30 Storeys or higher

Please tick one: Applicable Not Applicable

Applicable (√ ) /
Items Specific Design Tasks Carried Out Not Applicable (X)

(X)
(i) Designed for wind loads
(X)
(ii) Designed for notional loads

Stability system has been identified and evaluated to be adequate (X)


(iii)
and robust
(X)
Designed corewalls and columns to resist lateral loads due to wind
(iv)
and notional loads in both directions
(X)
(v) Provided adequate internal and peripheral ties at floor levels

(X)
Designed for capacities to resist base overturning moment and
(vi)
base shear
(X)
(vii) Designed for building sway (p-delta effect)

(X)
(viii) Designed to limit overall lateral deflection of building

(X)
(ix) Designed to limit inter-storey drift of building

(X)
Columns and walls have been checked for resistance to dynamic
(x)
effects due to wind on the building
(X)
(xi) Checked for Requirements for Wind Tunnel Tests

(X)
Checked for long term lateral deflection of building under gravity
(xii)
load

BEV/A3 Page 5 of 12
[Ver 3.0_Dec_2014]
(c) Building with Structural Steel Elements

Please tick one: Applicable Not Applicable

Applicable (√ ) /
Items Specific Design Tasks Carried Out Not Applicable (X)

(X)
Designed for bolted and welded connections of supports and
(i)
member and splice joints
(X)
(ii) Checked for in-plane and out-of-plane stability of frames
(X)
(iii) Designed for bracings and longitudinal ties for overall stability
(X)
(iv) Designed for wind load on the building/structure

Designed for lateral stability and torsional rigidity of structural (X)


(v)
elements and trusses

Support conditions assumed in design have been checked against (X)


(vi)
details provided

Type of joint connections provided between members are (X)


(vii)
consistent with joint rigidity adopted in the analysis and design

(d) Building with Precast Concrete Elements

Please tick one: Applicable Not Applicable

Applicable (√ ) /
Items Specific Design Tasks Carried Out
Not Applicable (X)

(X)
All joint connections between precast members and precast to in-
(i)
situ concrete members have been designed for
(√ )
Loading conditions on precast members during erection or
(ii)
construction stage have been considered
(X)
Sufficient rigidity in the structural frame has been provided for to
(iii)
resist lateral loads

(iv) Adequate internal & peripheral ties have been provided in floors (√ )

(v) All interface shear stresses have been checked (√ )

Detailing of precast elements and structural joints have been (X)


(vi)
checked

BEV/A3 Page 6 of 12
[Ver 3.0_Dec_2014]
(e) Building with Prestressed Concrete Structures

Please tick one: Applicable Not Applicable

Applicable (√ ) /
Items Specific Design Tasks Carried Out Not Applicable (X)

Maximum prestress force and prestress losses for prestressed (X)


(i)
elements have been computed according to code requirements
Stresses for elements have been checked at transfer and service (X)
(ii)
stages

(iii) Shear capacity has been designed for in prestressed elements (X)

(X)
For transfer beams and long span beams, consideration of stage
(iv)
stressing has been made in design
(X)
(v) End block design has been checked

(X)
Details of prestressed elements, tendon profile, etc. have been
(vi)
checked

(f) Building with Complex Structural Systems

Please tick one: Applicable Not Applicable

To contact BCA for


Items Structural Systems consultation (√ ) /
Not Applicable (X)

Structural system with more than 2 transfer floor levels of which (X)
(i) each carrying at least 3 floors; or structural system with
cantilever transfer element carrying more than 5 floors
Inclined or curved building (offset of floor plate more than 3m (X)
(ii)
from the edge of the floor above or below)
(X)
Structures with unconventional geometry (e.g. dome or arch-
(iii)
shaped)

Large span structures (with span more than 40m) or large (X)
(iv) cantilever span structures (where cantilever span is more than
8m)

BEV/A3 Page 7 of 12
[Ver 3.0_Dec_2014]
(III) Specific Structural Elements

Please tick one: Applicable Not Applicable

Locations in
Applicable (√ ) /
Structural Building
Specific Design tasks carried out Not Applicable (X)
Elements (Specify the
storey levels or
reference grids)

• Effective height has been


(X)
computed according to code

• Bending moment about minor


(X)
axis has been designed for
Slender Columns
• Additional bending moment due
to slenderness has been designed (X)
for

• Biaxial bending moment has


(X)
been designed for

Columns
• Designed for bending moment
supporting (X)
due to frame action
transfer beams

Columns
• Designed for bending moment
supporting long (X)
due to frame action
span beams

Columns • Designed for bending moment


supporting due to frame action (√ )
cantilever beams

• Designed for horizontal load and


moment acting on columns due (X)
to arched or pitched roof

Columns in a two
• Designed for bending moment at
column frame (√ )
the column base
system

• Designed for bending moment


(√ )
due to frame action

BEV/A3 Page 8 of 12
[Ver 3.0_Dec_2014]
Locations in
Applicable (√ ) /
Structural Building
Specific Design tasks carried out Not Applicable (X)
Elements * (specify the
storey levels or
reference grids)
• Cantilever support has been
designed to resist bending (√ )
moment and shear

Cantilever beams • Designed for lateral stability of


(√ )
beam

• Designed to meet allowable span


(√ )
depth ratio

• Torsional rigidity of beam has


been checked. (X)

• Designed for lateral restraint of


(X)
beams
Long span beams
• Designed for support and
(X)
member connections

• Designed to meet allowable span


(X)
depth ratio

• Designed for torsional capacity (X)

• Designed for shear capacity (X)

• Designed for all relevant upper


(X)
floor loads on the beam

• Designed for lateral restraint of


(X)
Transfer beams beam

• Transfer Beam supporting


sloping members designed for
(X)
both in-plane and out-of-plane
forces
• Comparison bending moments
and shear forces computation by
(X)
QP & AC carried out

BEV/A3 Page 9 of 12
[Ver 3.0_Dec_2014]
Locations in
Applicable (√ ) /
Structural Building
Specific Design tasks carried out Not Applicable (X)
Elements * (specify the
storey levels or
reference grids)
• Appropriate model used for
(√ )
analysis

• Span/depth ratio of slab has been


(√ )
checked

• Adequacy of top and bottom


reinforcement throughout slab (√ )
panel have been checked

Flat slabs/plates • Designed to resist punching


(√ )
shear from columns and walls
• Openings in slabs, especially
near columns, have been (X)
designed for
• Torsional rigidity at slab edges
(X)
has been checked

• Effects of construction loads


(X)
have been checked

• Designed tie-back anchorage to


(X)
resist pull-out

• Designed for lateral stability of


Cantilevered (X)
the structure
structures with
tie-backs • Designed for the durability of the
(X)
tie-backs

• Designed for redundancy to


(X)
resist total collapse

BEV/A3 Page 10 of 12
[Ver 3.0_Dec_2014]
(IV) Earth Retaining Structures

Please tick one: Applicable Not Applicable

Applicable (√ ) /
Items Specific Design tasks carried out
Not Applicable (X)

(X)
Geotechnical parameters adopted for design of ERSS are
(i)
consistent with site investigation report and published literature

(X)
Structure has been designed to resist overturning , sliding and
(ii)
bearing capacity failure

(X)
(iii) Structure has been designed to resist slip circle failure

(X)
Structure has been designed for onerous soil and water pressure
(iv)
acting on it

(X)
(v) Adequate surcharge load has been taken into account in design

(X)
ERSS checked for global stability, wall embedment, toe-stability,
(vi)
base heave and hydraulic uplift

(X)
Opening (service openings in wall), discontinuity in temporary
(vii)
retaining walls has been checked for stability.

(X)
Comparison of member forces computation for walls, struts, waler
(viii)
and kingposts by QP & AC has been carried out.

BEV/A3 Page 11 of 12
[Ver 3.0_Dec_2014]
Part C: - MAJOR SHORTCOMINGS DETECTED DURING CHECKING

Major Mistakes / Design Changes made by QP Due to My


Shortcomings Detected During Checking Checking

Part D: - OTHER COMMENTS BY AC

___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________
___________________________________________________________________________

I hereby certified that I have specifically carried out all the tasks for the foundation and
structural design as described in the tables above and confirmed that their design are
structurally adequate and safe.

Signature & stamp of AC: _______________________ Date: 01/8/2019

BEV/A3 Page 12 of 12