COMPRESSOR
LS20T
200-300HP/ 149-224KW
SUPERVISOR II
OPERATOR’S
MANUAL AND
PARTS LIST
KEEP FOR
FUTURE
REFERENCE
Part Number 02250137-722
©Sullair Corporation
AIR CARE
SEMINAR TRAINING
Sullair Air Care Seminars are 3-day courses that provide hands-on instruction in the proper operation,
maintenance and service of Sullair equipment. Individual seminars on Industrial compressors and com-
pressor electrical systems are presented at regular intervals throughout the year at a dedicated training
facility at Sullair’s corporate headquarters in Michigan City, Indiana.
Instruction includes discussion of the function and installation of Sullair service parts, troubleshooting of
the most common problems, and actual equipment operation. The seminars are recommended for main-
tenance and service personnel.
- Or Write -
Sullair Corporation
3700 E. Michigan Blvd.
Michigan City, IN 46360
Attn: Service Training Department
TABLE OF CONTENTS
Section 1 PAGE
SAFETY 1 1.1 GENERAL
1 1.2 PERSONAL PROTECTIVE EQUIPMENT
1 1.3 PRESSURE RELEASE
2 1.4 FIRE AND EXPLOSION
2 1.5 MOVING PARTS
2 1.6 HOT SURFACES, SHARP EDGES AND SHARP CORNERS
3 1.7 TOXIC AND IRRITATING SUBSTANCES
3 1.8 ELECTRICAL SHOCK
3 1.9 LIFTING
4 1.10 ENTRAPMENT
Section 2
DESCRIPTION 5 2.1 INTRODUCTION
5 2.2 DESCRIPTION OF COMPONENTS
5 2.3 SULLAIR COMPRESSOR UNIT,
FUNCTIONAL DESCRIPTION
6 2.4 COMPRESSOR COOLING AND LUBRICATION
SYSTEM, FUNCTIONAL DESCRIPTION
7 2.5 COMPRESSOR DISCHARGE SYSTEM,
FUNCTIONAL DESCRIPTION
16 2.6 CONTROL SYSTEM, FUNCTIONAL DESCRIPTION
22 2.7 AIR INLET SYSTEM, FUNCTIONAL DESCRIPTION
22 2.8 SUPERVISOR II PANEL BASIC INTRODUCTION
22 2.9 KEYPAD
24 2.10 STATUS DISPLAYS
25 2.11 LAMP INDICATORS
Section 3
SPECIFICATIONS 27 3.1 SPECIFICATIONS- LS20T
27 3.2 LUBRICATION GUIDE- STANDARD COMPRESSORS
28 3.3 APPLICATION GUIDE
TABLE OF CONTENTS
Section 4
INSTALLATION 31 4.1 MOUNTING OF COMPRESSOR
31 4.2 VENTILATION AND COOLING
31 4.3 SERVICE AIR PIPING
31 4.4 COUPLING ALIGNMENT CHECK
31 4.5 FLUID LEVEL CHECK
31 4.6 ELECTRICAL PREPARATION
32 4.7 MOTOR ROTATION DIRECTION CHECK
Section 5
OPERATION 33 5.1 GENERAL
33 5.2 PURPOSE OF CONTROLS
34 5.3 PARAMETERS SETUP
35 5.4 OPERATING THE COMPRESSOR
36 5.5 SUPERVISOR OUTPUT RELAYS
37 5.6 INITIAL START-UP PROCEDURE
37 5.7 SUBSEQUENT START-UP PROCEDURE
37 5.8 SHUTDOWN PROCEDURE
Section 6
MAINTENANCE 39 6.1 MAINTENANCE INTRODUCTION
39 6.2 DAILY OPERATION
39 6.3 MAINTENANCE AFTER INITIAL 50 HOURS OF
OPERATION
39 6.4 MAINTENANCE AS REQUIRED BY LUBRICATION
GUIDE (SECTION 3)
39 6.5 FLUID CHANGE
39 6.6 SEPARATOR MAINTENANCE
39 6.7 PARTS REPLACEMENT AND ADJUSTMENT PROCEDURES
39 FLUID FILTER MAINTENANCE
40 AIR FILTER MAINTENANCE
41 AIR/OIL SEPARATOR ELEMENTS REPLACEMENT
42 OIL RETURN/SIGHT GLASS MAINTENANCE
42 DIFFERENTIAL PRESSURE REGULATOR ADJUSTMENT
43 DRIVE COUPLING INSTALLATION AND ALIGNMENT
Section 7
TROUBLESHOOTING 45 7.1 TROUBLESHOOTING
45 7.2 TROUBLESHOOTING GUIDE
TABLE OF CONTENTS
Section 8
ILLUSTRATIONS 49 8.1 PROCEDURE FOR ORDERING PARTS
AND PARTS LIST 49 8.2 RECOMMENDED SPARE PARTS LIST
50 8.3 MOTOR, FRAME, COMPRESSOR AND PARTS
52 8.4 AIR INLET SYSTEM
56 8.5 FLUID COOLING SYSTEM- AIR-COOLED
58 8.6 WATER COOLING SYSTEM- WATER-COOLED
60 8.7 AIR PIPING SYSTEM- AIR-COOLED
62 8.8 AIR PIPING SYSTEM- WATER-COOLED
64 8.9 FLUID PIPING SYSTEM- AIR-COOLED
68 8.10 FLUID PIPING SYSTEM- WATER-COOLED
72 8.11 WATER PIPING SYSTEM- WATER-COOLED
74 8.12 DISCHARGE SYSTEM
78 8.13 CONTROL/START SYSTEM
82 8.14 CONTROL PANEL
84 8.15 ENCLOSURE AND ENCLOSURE DECALS
86 8.16 DECAL GROUP
92 8.17 DECAL LOCATIONS- OPEN AIR-COOLED
94 8.18 DECAL LOCATIONS- OPEN WATER-COOLED
96 8.19 DECAL LOCATIONS- CONTROL BOX
98 8.20 WIRING DIAGRAM- LS20T AIR-COOLED
99 8.21 WIRING DIAGRAM- LS20T WATER-COOLED
Section 1
SAFETY
1.1 GENERAL the service air outlet and the shut-off (throttle)
Sullair Corporation and its subsidiaries design and valve, either at the compressor or at any other point
manufacture all of their products so they can be along the air line, when an air hose exceeding
operated safely. However, the responsibility for 13mm inside diameter is to be connected to the
safe operation rests with those who use and main- shut-off (throttle) valve, to reduce pressure in case
tain these products. The following safety precau- of hose failure, per OSHA Standard 29 CFR
tions are offered as a guide which, if conscientious- 1926.302(b)(7) and/or any applicable Federal,
ly followed, will minimize the possibility of accidents State and Local codes, standards and regulations.
throughout the useful life of this equipment. B. When the hose is to be used to supply a mani-
The compressor should be operated only by those fold, install an additional appropriate flow-limiting
who have been trained and delegated to do so, and valve between the manifold and each air hose
who have read and understood this Operator’s exceeding13mm inside diameter that is to be con-
Manual. Failure to follow the instructions, proce- nected to the manifold to reduce pressure in case
dures and safety precautions in this manual may of hose failure.
result in accidents and injuries. C. Provide an appropriate flow-limiting valve at the
NEVER start the compressor unless it is safe to do beginning of each additional 23m of hose in runs of
so. DO NOT attempt to operate the compressor air hose exceeding13mm inside diameter to reduce
with a known unsafe condition. Tag the compressor pressure in case of hose failure.
and render it inoperative by disconnecting and lock- D. Flow-limiting valves are listed by pipe size and
ing out all power at source or otherwise disabling its flow-rated. Select appropriate valves accordingly, in
prime mover so others who may not know of the accordance with their manufacturer’s recommen-
unsafe condition cannot attempt to operate it until dations.
the condition is corrected.
E. DO NOT use air tools that are rated below the
Install, use and operate the compressor only in full maximum rating of the compressor. Select air tools,
compliance with all pertinent OSHA regulations air hoses, pipes, valves, filters and other fittings
and/or any applicable Federal, State, and Local accordingly. DO NOT exceed manufacturer’s rated
codes, standards and regulations. safe operating pressures for these items.
DO NOT modify the compressor and/or controls in F. Secure all hose connections by wire, chain or
any way except with written factory approval. other suitable retaining device to prevent tools or
While not specifically applicable to all types of com- hose ends from being accidentally disconnected
pressors with all types of prime movers, most of the and expelled.
precautionary statements contained herein are G. Open fluid filler cap only when compressor is not
applicable to most compressors and the concepts running and is not pressurized. Shut down the
behind these statements are generally applicable to compressor and bleed the sump (receiver) to zero
all compressors. internal pressure before removing the cap.
1.2 PERSONAL PROTECTIVE EQUIPMENT H. Vent all internal pressure prior to opening any
Prior to installing or operating the compressor, own- line, fitting, hose, valve, drain plug, connection or
ers, employers and users should become familiar other component, such as filters and line oilers, and
with, and comply with, all applicable OSHA regula- before attempting to refill optional air line anti-icer
tions and/or any applicable Federal, State and systems with antifreeze compound.
Local codes, standards, and regulations relative to I. Keep personnel out of line with and away from the
personal protective equipment, such as eye and discharge opening of hoses or tools or other points
face protective equipment, respiratory protective of compressed air discharge.
equipment, equipment intended to protect the
extremities, protective clothing, protective shields J. Use air at pressures less than 2.1 bar for clean-
and barriers and electrical protective equipment, as ing purposes, and then only with effective chip
well as noise exposure administrative and/or engi- guarding and personal protective equipment per
neering controls and/or personal hearing protective OSHA Standard 29 CFR 1910.242 (b) and/or any
equipment. applicable Federal, State, and Local codes, stan-
dards and regulations.
1.3 PRESSURE RELEASE K. DO NOT engage in horseplay with air hoses as
A. Install an appropriate flow-limiting valve between
1
Section 1
SAFETY
death or serious injury may result. environment unless the compressor has been spe-
cially designed and manufactured for that duty.
1.4 FIRE AND EXPLOSION
A. Clean up spills of lubricant or other combustible 1.5 MOVING PARTS
substances immediately, if such spills occur. A. Keep hands, arms and other parts of the body
B. Shut off the compressor and allow it to cool. and also clothing away from couplings, fans and
Then keep sparks, flames and other sources of other moving parts.
ignition away and DO NOT permit smoking in the B. DO NOT attempt to operate the compressor with
vicinity when checking or adding lubricant or when the fan, coupling or other guards removed.
refilling air line anti-icer systems with antifreeze C. Wear snug-fitting clothing and confine long hair
compound. when working around this compressor, especially
C. DO NOT permit fluids, including air line anti-icer when exposed to hot or moving parts.
system antifreeze compound or fluid film, to accu- D. Keep access doors, if any, closed except when
mulate on, under or around acoustical material, or making repairs or adjustments.
on any external surfaces of the air compressor.
Wipe down using an aqueous industrial cleaner or E. Make sure all personnel are out of and/or clear
steam clean as required. If necessary, remove of the compressor prior to attempting to start or
acoustical material, clean all surfaces and then operate it.
replace acoustical material. Any acoustical materi- F. Disconnect and lock out all power at source and
al with a protective covering that has been torn or verify at the compressor that all circuits are de-
punctured should be replaced immediately to pre- energized to minimize the possibility of accidental
vent accumulation of liquids or fluid film within the start-up, or operation, prior to attempting repairs or
material. DO NOT use flammable solvents for adjustments. This is especially important when
cleaning purposes. compressors are remotely controlled.
D. Disconnect and lock out all power at source prior G. Keep hands, feet, floors, controls and walking
to attempting any repairs or cleaning of the com- surfaces clean and free of fluid, water or other liq-
pressor or of the inside of the enclosure, if any. uids to minimize the possibility of slips and falls.
E. Keep electrical wiring, including all terminals and 1.6 HOT SURFACES, SHARP EDGES AND SHARP
pressure connectors in good condition. Replace CORNERS
any wiring that has cracked, cut, abraded or other- A. Avoid bodily contact with hot fluid, hot coolant,
wise degraded insulation, or terminals that are hot surfaces and sharp edges and corners.
worn, discolored or corroded. Keep all terminals
B. Keep all parts of the body away from all points
and pressure connectors clean and tight.
of air discharge.
F. Keep grounded and/or conductive objects such
C. Wear personal protective equipment including
as tools away from exposed live electrical parts
gloves and head covering when working in, on or
such as terminals to avoid arcing which might serve
around the compressor.
as a source of ignition.
D. Keep a first aid kit handy. Seek medical assis-
G. Remove any acoustical material or other materi-
tance promptly in case of injury. DO NOT ignore
al that may be damaged by heat or that may sup-
small cuts and burns as they may lead to infection.
port combustion and is in close proximity, prior to
attempting weld repairs. 1.7 TOXIC AND IRRITATING SUBSTANCES
H. Keep suitable fully charged Class BC or ABC fire A. DO NOT use air from this compressor for respi-
extinguisher or extinguishers nearby when servic- ration (breathing) except in full compliance with
ing and operating the compressor. OSHA Standards 29 CFR 1910 and/or any applica-
ble Federal, State or Local codes or regulations.
I. Keep oily rags, trash, leaves, litter or other com-
bustibles out of and away from the compressor.
J. DO NOT operate the compressor without proper
flow of cooling air or water or with inadequate flow Death or serious injury can result from inhaling
of lubricant or with degraded lubricant. compressed air without using proper safety
equipment. See OSHA standards and/or any
K. DO NOT attempt to operate the compressor in applicable Federal, State, and Local codes,
any classification of hazardous standards and regulations on safety equipment.
2
Section 1
SAFETY
B. DO NOT use air line anti-icer systems in air lines making adjustments or repairs to exposed live parts
supplying respirators or other breathing air utiliza- of the electrical system. Make all such adjustments
tion equipment and DO NOT discharge air from or repairs with one hand only, so as to minimize the
these systems into unventilated or other confined possibility of creating a current path through the
areas. heart.
C. Operate the compressor only in open or ade- C. Attempt repairs in clean, dry and well lighted and
quately ventilated areas. ventilated areas only.
D. Locate the compressor or provide a remote inlet D. DO NOT leave the compressor unattended with
so that it is not likely to ingest exhaust fumes or open electrical enclosures. If necessary to do so,
other toxic, noxious or corrosive fumes or sub- then disconnect, lock out and tag all power at
stances. source so others will not inadvertently restore
E. Coolants and lubricants used in this compressor power.
are typical of the industry. Care should be taken to E. Disconnect, lock out, and tag all power at source
avoid accidental ingestion and/or skin contact. In prior to attempting repairs or adjustments to rotating
the event of ingestion, seek medical treatment machinery and prior to handling any ungrounded
promptly. Wash with soap and water in the event of conductors.
skin contact. Consult Material Safety Data Sheet for
information pertaining to fluid of fill. 1.9 LIFTING
A. If the compressor is provided with a lifting bail,
F. Wear goggles or a full face shield when adding then lift by the bail provided. If no bail is provided,
antifreeze compound to air line anti-icer systems. then lift by sling. Compressors to be air-lifted by hel-
G. If air line anti-icer system antifreeze compound icopter must not be supported by the lifting bail but
enters the eyes or if fumes irritate the eyes, they by slings instead. In any event, lift and/or handle
should be washed with large quantities of clean only in full compliance with OSHA standards 29
water for fifteen minutes. A physician, preferably an CFR 1910 subpart N and/or any applicable Federal,
eye specialist, should be contacted immediately. State, and Local codes, standards and regulations.
H. DO NOT store air line anti-icer system antifreeze B. Inspect points of attachment for cracked welds
compound in confined areas. and for cracked, bent, corroded or otherwise
I. The antifreeze compound used in air line degraded members and for loose bolts or nuts prior
antifreeze systems contains methanol and is toxic, to lifting.
harmful or fatal if swallowed. Avoid contact with the C. Make sure entire lifting, rigging and supporting
skin or eyes and avoid breathing the fumes. If swal- structure has been inspected, is in good condition
lowed, induce vomiting by administering a table- and has a rated capacity of at least the weight of
spoon of salt, in each glass of clean, warm water the compressor. If you are unsure of the weight,
until vomit is clear, then administer two teaspoons then weigh compressor before lifting.
of baking soda in a glass of clean water. Have D. Make sure lifting hook has a functional safety
patient lay down and cover eyes to exclude light. latch or equivalent, and is fully engaged and latched
Call a physician immediately. on the bail or slings.
1.8 ELECTRICAL SHOCK E. Use guide ropes or equivalent to prevent twisting
A. This compressor should be installed and main- or swinging of the compressor once it has been lift-
tained in full compliance with all applicable Federal, ed clear of the ground.
State and Local codes, standards and regulations, F. DO NOT attempt to lift in high winds.
including those of the National Electrical Code, and
also including those relative to equipment ground- G. Keep all personnel out from under and away
ing conductors, and only by personnel that are from the compressor whenever it is suspended.
trained, qualified and delegated to do so. H. Lift compressor no higher than necessary.
B. Keep all parts of the body and any hand-held I. Keep lift operator in constant attendance when-
tools or other conductive objects away from ever compressor is suspended.
exposed live parts of electrical system. Maintain dry J. Set compressor down only on a level surface
footing, stand on insulating surfaces and DO NOT capable of safely supporting at least its weight and
contact any other portion of the compressor when its loading unit.
3
Section 1
SAFETY
K. When moving the compressor by forklift truck, attempt to forklift a compressor that is not secured
utilize fork pockets if provided. Otherwise, utilize to its pallet, as uneven floors or sudden stops may
pallet if provided. If neither fork pockets or pallet cause the compressor to tumble off, possibly caus-
are provided, then make sure compressor is secure ing serious injury or property damage in the
and well balanced on forks before attempting to process.
raise or transport it any significant distance.
1.10 ENTRAPMENT
L. Make sure forklift truck forks are fully engaged A. If the compressor enclosure, if any, is large
and tipped back prior to lifting or transporting the enough to hold a man and if it is necessary to enter
compressor. it to perform service adjustments, inform other per-
M. Forklift no higher than necessary to clear obsta- sonnel before doing so, or else secure and tag the
cles at floor level and transport and corner at mini- access door in the open position to avoid the pos-
mum practical speeds. sibility of others closing and possibly latching the
N. Make sure pallet-mounted compressors are door with personnel inside.
firmly bolted or otherwise secured to the pallet prior B. Make sure all personnel are out of compressor
to attempting to forklift or transport them. NEVER before closing and latching enclosure doors.
4
Section 2
DESCRIPTION
2.1 INTRODUCTION compressor discharge system, compressor
Your new Sullair lubricated rotary screw air com- cooling and lubrication system, capacity con-
pressor will provide you with a unique experience in trol system and “Supervisor II Control System”
improved reliability and greatly reduced mainte- all mounted on a structural steel frame.
nance. On air-cooled models, the cooling package is
Compared to other types of compressors, the mounted within the package. The separate motor-
Sullair rotary screw is unique in mechanical reliabil- driven fan cooling package forces air through the
ity, with “no wear” and “no inspection” required of coolers, which removes the heat of compression
the working parts within the compressor unit. from the cooling fluid.
Read Section 6 (Maintenance) to see how surpris- Both air-cooled and water-cooled versions have
ingly easy it is to keep your air compressor in top easily accessible items such as the fluid filters and
operating condition. Should any questions arise control valves. The inlet air filters are also mounted
which cannot be answered in the following text, call for easy access and servicing.
your nearest Sullair representative or the Sullair 2.3 SULLAIR COMPRESSOR UNIT, FUNCTIONAL
Corporation Service Department. DESCRIPTION
2.2 DESCRIPTION OF COMPONENTS Sullair air compressors feature the Sullair compres-
Refer to Figures 2-1A and 2-1B. The components sor unit, a two-stage, positive displacement, lubri-
and assemblies of the air compressor are clearly cated-type compressor. This unit provides continu-
shown. The complete package includes compres- ous pulse-free air compression to meet your needs.
sor, electric motor, compressor inlet system, With a Sullair compressor, there is no maintenance
Figure 2-1A Sullair Series LS20T Rotary Screw Compressor- Air-cooled (Typical)
5
Section 2
DESCRIPTION
Figure 2-1B Sullair Series LS20T Rotary Screw Compressor- Water-cooled (Typical)
or inspection of the internal parts of the compressor and lubrication system consists of a fluid cooler,
unit permitted in accordance with the terms of the aftercooler, full flow fluid filters, fluid stop valve,
warranty. thermal valve and interconnection piping. For
Fluid is injected into the compressor unit at each water-cooled models, a shell and tube fluid cooler
stage, and mixes directly with the air as the rotors and aftercooler are mounted on the compressor
turn, compressing the air. The fluid flow has three package. For air-cooled models, they are radiator-
main functions: type coolers, and are mounted on the compressor
package.
• As coolant, it controls the rise of air temper-
ature normally associated with the heat of The pressure in the receiver/sump causes fluid flow
compression. by forcing the fluid from the high pressure area of
the sump to an area of lower pressure in the com-
• Seals the leakage paths between the rotors pressor unit.
and the stator and also between the rotors
themselves. Fluid flows from the bottom of the receiver/sump to
the thermal valve. The thermal valve is fully open
• Acts as a lubricating film between the rotors when the discharge temperature is below 220ºF
allowing one rotor to directly drive the other, (104.4ºC). The fluid passes through the thermal
which is an idler. valve, the main fluid filter and directly to the com-
After the air/fluid mixture is discharged from the pressor unit, thus feeding the bearings, seals and
compressor unit, the fluid is separated from the air. rotor area.
At this time, the air flows to the service line and the As the discharge temperature rises above 220ºF
fluid is cooled in preparation for reinjection. (104.4ºC), due to the heat of compression, the ther-
2.4 COMPRESSOR COOLING AND LUBRICATION mal valve begins to close and a portion of the fluid
SYSTEM, FUNCTIONAL DESCRIPTION then flows through the cooler. From the cooler, the
Refer to Figures 2-2, 2-3A and 2-3B. The cooling
6
Section 2
DESCRIPTION
fluid flows to the main filter and on to the compres- The compressed air/fluid mixture enters the receiv-
sor unit. The fluid filter has a replacement element er and is directed against the ends of the tank. The
and an integral pressure bypass valve. direction of movement is changed and its velocity
The fluid stop valve prevents fluid from filling the significantly reduced, thus causing large droplets of
compressor unit when the compressor is shut fluid to form and fall to the bottom of the
down. When the compressor is operating, the fluid receiver/sump. The fractional percentage of fluid
stop valve is held open by air pressure from the remaining in the compressed air collects on the sur-
compressor unit allowing a free flow of fluid from faces of the dual separator elements as the com-
the receiver/sump back to the compressor unit. On pressed air flows through them. Two return lines (or
shutdown, the compressor unit pressure is scavenge tubes) lead from the bottom of each sep-
reduced, causing the fluid stop valve to close and arator element to the interstage of the compressor
isolate the compressor unit from the cooling sys- unit. Fluid collecting on the bottom of each separa-
tem. tor is returned to the compressor by a pressure dif-
ference between the receiver and the compressor.
2.5 COMPRESSOR DISCHARGE SYSTEM, FUNC- Sight glasses are located in the return lines to
TIONAL DESCRIPTION observe this fluid flow. There are also orifices in this
Refer to Figures 2-2, 2-3A and 2-3B. The compres- return line (protected by strainers) to assure proper
sor unit discharges the compressed air/fluid mois- flow. By pressing the dP1 pad on the Supervisor,
ture through a discharge check valve into the com- the operator may monitor the condition of the sep-
bination receiver/sump. The discharge check valve arator elements by reading differential pressure on
prevents air in the receiver from returning to the the digital display. At a differential of 10 psid (0.7
compression chamber after the compressor has bar) or greater, the operator will be told to service
been shut down. The receiver has three functions: the separator element. At this time, separator ele-
• It acts as a primary fluid separator. ment replacement is necessary.
• Serves as the compressor fluid sump. The receiver is an ASME pressure vessel. A com-
• Houses the final fluid separator elements. bination minimum pressure/check valve, located
7
Section 2
DESCRIPTION
Figure 2-3A Compressor Piping and Instrumentation Diagram- LS20T-200 Air-cooled
8
Section 2
DESCRIPTION
Figure 2-3A Compressor Piping and Instrumentation Diagram- LS20T-200 Air-cooled
key part
number description number quantity
9
Section 2
DESCRIPTION
Figure 2-3A Compressor Piping and Instrumentation Diagram- LS20T-200 Air-cooled
10
Section 2
DESCRIPTION
Figure 2-3A Compressor Piping and Instrumentation Diagram- LS20T-200 Air-cooled (Continued)
key part
number description number quantity
11
Section 2
DESCRIPTION
Figure 2-3B Compressor Piping and Instrumentation Diagram- LS20T-200 Water-cooled
12
Section 2
DESCRIPTION
Figure 2-3B Compressor Piping and Instrumentation Diagram- LS20T-200 Water-cooled
key part
number description number quantity
13
Section 2
DESCRIPTION
Figure 2-3B Compressor Piping and Instrumentation Diagram- LS20T-200 Water-cooled
14
Section 2
DESCRIPTION
Figure 2-3B Compressor Piping and Instrumentation Diagram- LS20T-200 Water-cooled (Continued)
key part
number description number quantity
15
Section 2
DESCRIPTION
downstream from the separator, assures a mini- pressures.
mum receiver pressure of 160 psig (11bar) during START MODE - TO 160 PSIG (11 BAR)
full load operation. This pressure is necessary for When the compressor start button is depressed, the
proper air/fluid separation and proper fluid circula- pressure will rise from 0 to 160 psig (0 to 11 bar).
tion while supplying air to the system. This valve During this period, the control inlet solenoid is
also acts as a check valve preventing compressed closed, which keeps the inlet poppet valve closed.
air in the service line from bleeding back into the The control pressure regulator is also closed at this
receiver on shutdown and during operation on the time. After the startup timer times out, the startup
compressor in an unloaded condition. solenoid valve changes state and the reference
A pressure relief valve (located on the wet side of pressure regulator controls the pressure signal to
the separator) is set to open at rated tank pressure. the poppet valve at a maximum 60 psig (4 bar).
The compressor is also equipped with high pres- The inlet poppet valve opens allowing full airflow to
sure shutdown protection to shut down at high MAX the compressor inlet and the discharge pressure
P1 setpoint. This prevents the relief valve from builds to approximately 160 psig (11 bar). No air is
opening. High temperature probes are provided to supplied to the system service line during this
shut down the compressor. phase by the minimum pressure valve. When the
discharge pressure exceeds approximately 160
psig (11 bar), the minimum pressure valve may start
to open and allow air to flow to the system service
DO NOT remove caps, plugs, and/or other compo-
nents when compressor is running or pressurized. line.
Stop compressor and relieve all internal pressure NORMAL OPERATION MODE - 160 TO 350 PSIG
before doing so. (11 TO 24.1 BAR)
When the sump pressure rises above 160 psig (11
Fluid is added to the sump via a capped fluid filler
bar), the minimum pressure valve opens and deliv-
opening, located on the tank to prevent overfilling of
ers compressed air to the system service line.
the sump. A sight glass enables the operator to
From this point on, a line air pressure transducer
visually monitor the sump fluid level.
continually monitors the air pressure. The control
2.6 CAPACITY CONTROL SYSTEM, FUNCTIONAL pressure regulator valve remains closed during this
DESCRIPTION phase, keeping the inlet poppet valve wide open.
Refer to Figures 2-3A, 2-3B and 2-4 (A through E). The blowdown solenoid valve also remains closed
The purpose of the compressor control system is to during this phase. Flow will occur when the dis-
regulate the compressor air intake to match the charge pressure is higher than the line pressure.
amount of compressed air being utilized. At 0 to 10 The check valve, which is built into the minimum
percent air output, the control system will automati- pressure valve, will prevent back flow into the com-
cally unload the compressor and reduce power con- pressor.
sumption. The unload sump pressure can be set
MODULATING MODE - 350 TO 360 PSIG (24.1 TO
using the unload control regulator valve (140-175
24.8 BAR)
psig).
If less than the rated capacity of compressed air is
The Control System consists of an inlet poppet being used, the system service line pressure will
valve, startup solenoid valve, reference (equal- rise above 350 psig (24.1 bar). The control pres-
izing) pressure regulator, blowdown solenoid sure regulator valve gradually opens applying air
valve, pneumatic blowdown valve, control pres- pressure to the control side of the inlet poppet
sure regulator, unload pressure regulator, valve, which modulates the position of the inlet pop-
sequencing solenoid valve, and a control line fil- pet valve. This reduces the amount of air entering
ter located prior to the controls. the compressor until it matches the amount of air
The functional description of the Control System is being utilized. The control system functions contin-
described below in five distinct phases of the com- ually in this manner, between the limits of 350 to
pressor operation. For explanation purposes, this 360 psig (24.1 to 24.8 bar) in response to varying
description will apply to compressors with an oper- demands from system service line. The control
ating range of 350 to 360 psig (24.1 to 24.8 bar). A pressure regulator valve has an orifice, which vents
compressor with any other pressure range would a small amount of air to the atmosphere when the
operate in a similar manner except for the stated control pressure regulator valve modulates the inlet
poppet valve.
16
Section 2
DESCRIPTION
Figure 2-4A Control System Diagram- Functional Components
17
Section 2
DESCRIPTION
Figure 2-4B Control System Diagram- START
18
Section 2
DESCRIPTION
Figure 2-4C Control System Diagram- MODULATION
19
Section 2
DESCRIPTION
Figure 2-4D Control System Diagram- FULL LOAD
20
Section 2
DESCRIPTION
Figure 2-4E Control System Diagram- UNLOAD
21
Section 2
DESCRIPTION
UNLOAD MODE - EXCESS OF 360 PSIG (24.8 ing light when the message “AIR FILTER MAINT
BAR) RQD” is required.
As the required air is reduce, the discharge pres- The poppet-type air inlet valve directly controls the
sure and line pressure rise above the 360 psig (24.8 amount of air intake to the compressor in response
bar), the Supervisor activates the unload solenoid to the operation of the controls (see Section 2.6,
valve which in turn pressurizes the blowdown valve. Control System, Functional Description).
This opens the blowdown valve, which allows dis-
charge air to flow back to the compressor inlet. 2.8 SUPERVISOR II PANEL BASIC INTRODUCTION
Since the inlet poppet valve is fully closed, the air Refer to Figure 2-6. The Supervisor II has a two line
pressure from the sump tank will be relieved display to show temperature, pressure and status. It
through the blowdown valve, which will reduce the has a keypad for operating the compressor, pro-
sump pressure. Some of the outgoing air will flow gramming the control points and selecting displays.
directly into the compressor inlet to avoid cavitation There is a graphic illustration with lamps that light to
during this time of blowdown. As the sump pres- show the item being displayed. The lamps flash if
sure drops, motor power consumption is also that component is in an alarm condition.
reduced. The unload pressure regulator is set to 2.9 KEYPAD
maintain the unload pressure at a designated value, The keypad is used to control the machine as well
between 140 and 175 psig (9.6 to 12 bar). At this as display status and change setpoints. Refer to fig-
time, the compressor is in the unload mode. ure 2-6 for following key descriptions.
When the line pressure drops back to the load point • Stop - Used to put the machine into manual
(cut-in pressure) of the pressure transducer, usual- stop. It is also used to clear alarm condi-
ly 350 psig (24.1 bar), the compressor will change tions.
state back to the modulating mode as discussed
earlier. This cycle will repeat itself, maintaining the
demand required on the system line supply.
SHUTDOWN MODE Figure 2-5 Air Inlet System
When the compressor is shut down based on a
manual shutdown, a safety shutdown or an auto-
matic shutdown from the Supervisor touch pad, the
unload solenoid valve is energized allowing air to
flow through the check valve and into the poppet
valve keeping the inlet poppet valve closed. This
also opens the blowdown valve to allow com-
pressed air to vent back above inlet poppet valve
through the inlet filter. The control lines are proper-
ly sized and routed to allow the compressed air to
relieve to atmosphere rather than below the inlet
poppet valve.
If the compressor Supervisor controller is in the
automatic mode, the compressor will shut down
after running unloaded for a specific amount of
time. The reverse also holds true, if the system line
pressure requires additional compressed air, the
compressor will start automatically to satisfy this
demand.
2.7 AIR INLET SYSTEM, FUNCTIONAL DESCRIP-
TION
Refer to Figure 2-5. The Compressor Inlet
System consists of a dry-type air filter, a vacuum
switch, and an air inlet valve.
The vacuum switch, located on the compressor
Supervisor Control System, indicates with a flash-
22
Section 2
DESCRIPTION
Figure 2-6 Supervisor II Panel
• Continuous - Starts machine if no alarm • Logo - Used for various functions described
conditions are present. Also used to clear in later sections
alarm conditions while machine is running.
23
Section 2
DESCRIPTION
plays to change displays and in parameter shown with the default display. The machine status
setup mode to increment a value. When in will be displayed for 2 seconds then the alarms for
the default display the key will light all the 2 seconds each. For example:
lamps for three seconds.
T1 HI
360 220
• SEQ STOP - Compressor is off but armed to • Oil differential pressure and the minimum
start. The machine will start when the limit. If the pressure goes below the limit a
sequencing conditions meet the criteria to P3 LOW shutdown will occur. Oil differential
start. (dP3) is defined as P3-P1/2
dP3 40
The machine may start at any time. MIN 1
This default display appears as follows: • Unit discharge temperature and the maxi-
mum limit. If the temperature exceeds the
STOP limit a T1 HI shutdown will occur.
360 220
T1 210
If there are alarms active they will alternately be MAX 255
24
Section 2
DESCRIPTION
• Dry side discharge temperature and the is being displayed, if flashing denotes the presence
maximum limit. If the temperature exceeds of an alarm.
the limit a T2 HI shutdown will occur. P3 - Injection oil pressure (Pressure after oil filter)
Same as P1 & P2 except for P3.
T2 210
P4 - (Pressure before oil filter)
MAX 255
dP1 - (Separate differential pressure) If lit steady,
• Oil temperature and the maximum limit. If signifies that DP1 is being displayed, if flashing
the temperature exceeds the limit a T4 HI denotes replacement of separator is needed.
shutdown will occur. dP2 - (Oil filter differential pressure)
dP3 - (Oil differential pressure)
T4 210
T1 - (Dry side discharge temperature) If lit steady,
MAX 255
signifies that T1 is being displayed, if flashing
denotes the presence of an alarm.
• Total hours that the compressor has been
running. T2 - (Discharge temperature) If lit steady, signifies
that T2 is being displayed, if flashing denotes the
HRS RUN presence of an alarm.
001234.0 T3 - (Oil temperature) If lit steady, signifies that T3
is being displayed. For monitoring only.
• Total hours that the compressor has been T4 - (Interstage temperature) If lit steady, signifies
loaded. that T4 is being displayed, if flashing denotes the
presence of an alarm.
HRS LOAD
000987.0
For T1, T2 and T4, shutdown points are at 255ºF
• Last fault log. This shows the fault on the (124ºC) with a 30 second delay, and 275ºF (135ºC )
first line and the run hours when the fault immediate.
occurred.
MOTOR - If flashing, indicates the motor overload
T1 HI contact has opened.
@1 255 INLET FILTER - If flashing, indicates that inlet filter
maintenance is needed.
• Next to last fault log. This shows the fault on OIL FILTER - If flashing, indicates that oil filter
the first line and the run hours when the fault maintenance is needed.
occurred. POWER ON - Lit if 120VAC power is applied to the
Supervisor II.
T1 HI
ON - If lit steady, the compressor is running. If flash-
@2 224
ing, indicates that the compressor is armed but
stopped because of restart timer not expired,
2.11 LAMP INDICATORS
remote stop or sequence stop. The compressor
Embedded into the front panel schematic of the
may start at any time.
compressor are several lamps. Pressing the lamp
test key will light all the lamps for 3 seconds. Each AUTO - If lit steady, the compressor is running and
LED lamp has the following purpose. in auto mode. If flashing, indicates that the com-
pressor is armed but stopped because of restart
P1 - (Line pressure) If lit steady, signifies that P1 is
timer not expired, remote stop or sequence stop.
being displayed, if flashing denotes the presence of
The compressor may start at any time.
an alarm.
P2 - (Sump pressure) If lit steady, signifies that P2
25
NOTES
26
Section 3
SPECIFICATIONS
3.1 SPECIFICATIONS- LS20T
DIMENSIONS WITHOUT ENCLOSURE (I)
Model Series Length Width Height Weight
in mm in mm in mm lb kg
LS20T 500 CFM 143.5 3645 64 1626 71.5 1816 6000 2722
LS20T 630 CFM 143.5 3645 64 1626 71.5 1816 6000 2722
LS20T 750 CFM 143.5 3645 64 1626 71.5 1816 6000 2722
(I) For information concerning enclosed compressors, please contact the Sullair Factory Sales Department.
For noise level information, please contact the Sullair Factory Service Department.
COMPRESSOR:
Type: 2-Stage Oil Flooded Rotary
Maximum Full Load Operating Pressure: 350 psig (24.1 bar)
Bearing Type: Anti-Friction
Cooling: Pressurized Compressor Fluid
Lubricant: Sullube
Sump Capacity: 35 U.S. Gallons (132 Liters)
Control: Supervisor II Controller
MOTOR:
Type: O.D.P., 460V, A.C., Three Phase, 60 Cycles
Size: See Model Series above.
Speed: 1200 RPM and 1800 RPM
3.2 LUBRICATION GUIDE-STANDARD COMPRES- Figure 3-1 Fluid Fill Port Location
SORS
Refer to Figure 3-1 for fluid fill port location. Sullair
standard compressors are filled with Sullube fluid
as factory fill.
27
Section 3
SPECIFICATIONS
Maintenance of all other components is still recom- 3.3 APPLICATION GUIDE
mended as indicated in the Operator’s Manual. Sullair encourages the user to participate in a fluid
analysis program with the fluid suppliers. This could
result in a fluid change interval differing from that
Mixing of other lubricants within the compressor stated in the manual. Contact your Sullair dealer for
unit will void all warranties!
details.
“The Plastic Pipe Institute recommends against
the use of thermoplastic pipe to transport com-
pressed air or other compressed gases in
exposed above ground locations, e.g. in exposed
plant piping.” (I)
Sullube should not be used with PVC piping sys-
tems. It may affect the bond at cemented joints.
Certain other plastic materials may also be affect-
ed.
(I) Plastic Pipe Institute, Recommendation B,
Adopted January 19, 1972.
28
Section 3
SPECIFICATIONS
Figure 3-2 Identification LS20T 200HP Air-cooled with Supervisor II
02250135-562R00
29
Section 3
SPECIFICATIONS
Figure 3-3 Identification LS20T 200HP Water-cooled with Supervisor II
02250133-439R01
30
Section 4
INSTALLATION
4.1 MOUNTING OF COMPRESSOR DO NOT install a water-cooled or an air-
A foundation or mounting capable of supporting the cooled/aftercooled compressor without adequate
weight of the compressor, and rigid enough to main- freeze protection where it will be exposed to tem-
tain the compressor frame level and the compres- perature less than 32ºF(0ºC).
sor in alignment is required. The compressor frame 4.3 SERVICE AIR PIPING
must be leveled and secured with foundation bolts, Service air piping should be installed as shown in
and full uniform contact must be maintained Figure 4-1. A shut-off valve should be installed to
between the frame and foundation. It is recom- isolate a compressor from the service line if
mended that the frame be grouted to the founda- required. Also notice that the service line should be
tion. The compressor unit and driver must be equipped with water legs and condensate drains
aligned after installation as specified in this throughout the system.
Operator’s Manual. No piping loads shall be trans-
mitted to the compressor or the cooling package at
the external connections. “The Plastic Pipe Institute recommends against
the use of thermoplastic pipe to transport com-
4.2 VENTILATION AND COOLING
pressed air or other compressed gases in
For air-cooled compressors, select a location to exposed above ground locations, e.g. in exposed
permit sufficient unobstructed air flow in and out to plant piping.” (I)
the compressor to keep the operating temperature Sullube should not be used with PVC piping sys-
stable. The minimum distance that the compressor tems. It may affect the bond at cemented joints.
should be from surrounding walls is 4 feet/1.22m. Certain other plastic materials may also be affect-
To prevent excessive ambient temperature rise, it is ed.
imperative to provide adequate ventilation. (I) Plastic Pipe Institute, Recommendation B,
For water-cooled compressors, it is necessary to Adopted January 19, 1972.
check the cooling water supply. The water system 4.4 COUPLING ALIGNMENT CHECK
must be capable of supplying the following flows: In preparation for the factory test, the coupling sup-
MODEL-HP/KW WATER FLOW (GPM) plied with your compressor is properly aligned for
operation. The motor is flange-mounted to the com-
LS20T- 200HP/149KW 36
pressor unit adapter. Therefore, it is not necessary
LS20T- 250HP/186KW 48
to check this alignment, unless high vibration is
LS20T- 300HP/224KW 50
noticed.
Table 4-1 Ventilation Requirements indicates the
4.5 FLUID LEVEL CHECK
ventilation requirements necessary to keep the
Your air compressor is also supplied with the prop-
compressor running at a normal operating temper-
er amount of fluid. However, it is necessary to check
ature. The fan air requirement is the volume of air
the fluid level at installation. The level is checked by
which must flow through the compressor for proper
looking at the sight glass located on the sump. If the
ventilation. The specified heat rejection requirement
sump is properly filled, the coolant level should fill
is the amount of heat that is radiated by the com-
1/2 of the sight glass when the compressor is shut-
pressor. This heat must be removed to assure a
down.
normal operating temperature. With air-cooled com-
pressors it is possible to use this heat for space 4.6 ELECTRICAL PREPARATION
heating, providing excessive pressure drop is not Interior electrical wiring is performed at the factory.
created across the fan. Consult a Sullair office for Required customer wiring is minimal, but should be
assistance in utilizing this heat. done by a qualified electrician in compliance with
Table 4-1 Ventilation Requirements
WATER COOLED OR REMOTE COOLED AIR-COOLED (I)
COMPRESSOR PACKAGE COOLING PACKAGE
HEAT REJECTION VENT FAN FLOW (II) HEAT REJECTION AIR FLOW
MODEL MOTOR HP/KW BTU/HR CFM BTU/HR CFM
LS20T-200 200/149 50,880 2,800 534,240 18,500
LS20T-250 250/186 63,600 2,800 674,160 18,500
LS20T-300 300/224 76,320 2,800 807,360 18,500
31
Section 4
INSTALLATION
Figure 4-1 Service Air Piping
any applicable regional or local electrical code con- and use the cursor pad to change to MANUAL
cerning isolation switches, fuse disconnects, etc. mode.
Sullair provides a wiring diagram for use by the 5. Reconnect the three (3) motor leads and jog the
installer. motor for a direction of rotation check, as
explained in Section 4.7.
32
Section 5
OPERATION
5.1 GENERAL will call for service or indicate the beginning of a
While Sullair has built into this compressor a com- malfunction. Before starting your Sullair compres-
prehensive array of controls and indicators to sor, read this section thoroughly and familiarize
assure you that it is operating properly, you will yourself with the controls and indicators - their pur-
want to recognize and interpret the reading which pose, location and use.
SEPARATOR RETURN LINE SIGHT Used to indicate fluid flow in the return lines. When the com-
GLASS pressor is running at full load, fluid flow should be visible in
this sight glass. There may b little or no flow when the com-
pressor is running unloaded, but a sluggish flow at full load
indicates a need to clean the return line strainer.
FLUID STOP VALVE Cuts off flow of fluid to compressor unit at compressor shut-
down and allows flow of fluid to the unit on startup.
DISCHARGE CHECK VALVE Cuts off the reverse flow of air/fluid mixture through compres-
sor discharge system at compressor shutdown.
THERMAL VALVE Regulates flow of fluid to and around the cooler. Designed to
maintain a minimum operating temperature of 220ºF (104ºC).
Also used for fast warm-up on startup.
MINIMUM PRESSURE/CHECK VALVE Maintains minimum of 160 psig (11bar) in the compressor
sump. Valve piston restricts receiver air discharge from
receiver/sump when pressure falls to 160 psig (11bar).
Prevents line pressure backflow into the sump during unload
conditions and after shutdown.
PRESSURE RELIEF VALVE (SUMP) Opens sump pressure to the atmosphere should pressure
inside the sump becomes too high (375 psig [25.8 bar]).
Operation of this valve indicates that the high pressure trans-
ducer is either faulty or out of adjustment.
PRESSURE RELIEF VALVE (INTER- Opens interstage of compressor to atmosphere should the
STAGE) pressure become too high (150 psig [10.3 bar]). Operation of
this valve indicates unit pressurization during shutdown.
Causes may be plugged control lines, faulty discharge check
valve, or faulty fluid stop valve.
INLET POPPET VALVE Regulates the amount of air allowed to enter the air inlet
valve. This regulation is determined by the amount of air
being used at the service line.
PRESSURE REGULATOR (INLET POP- Opens a pressure line between the sump and inlet poppet
PET VALVE) valve allowing to regulate air delivery according to the air
demand.
33
Section 5
OPERATION
5.2 PURPOSE OF CONTROLS (CONTINUED)
CONTROL OR INDICATION PURPOSE
PRESSURE REGULATOR (UNLOAD) Opens a pressure line between the sump and the inlet poppet
valve to regulate the unload pressure.
PRESSURE REGULATOR (REFERENCE) Opens a pressure line between the sump and the inlet poppet
valve after initial startup. This pressure overcomes the inter-
nal spring load, allowing the inlet poppet valve the ability to
modulate as required by the service line.
STARTUP SOLENOID VALVE Assures no flow to the reference regulator during startup for
approximately 7-sec. After the timer times out, this valve
opens to allow air to flow to the reference pressure regulator.
EMERGENCY STOP SWITCH Pushing in this switch, found adjacent to the Supervisor, cuts
all AC outputs from the latter and de-energizes the starter. A
fault message (E STOP) is displayed by the Supervisor until
the button is pulled out and the “O” pad is depressed.
34
Section 5
OPERATION
there may be times when the machine will • Drain time - The amount of time that the
run unloaded for more than 5 minutes. This drain valve is actuated.
is because there is another timer that keeps
the machine from being started more than DRN TIM
four times an hour. 1 SEC
UNLD TIM
• Last Communication Number - Used only
15 MIN for sequencing, see Sequencing & Protocol
Manual for details.
• Language select - English, German,
Spanish, Italian and French may be select- LAST COM
ed for display language.
3
LANGUAGE
• Lowest Allowable Pressure - Used only for
ENGLISH
sequencing, see Sequencing & Protocol
• Units - English or metric units may be Manual for details.
selected.
LOWEST
UNITS 90 PSI
ENGLISH
• Recovery Time - Used only for sequencing,
• Communications ID # - This is the network see Sequencing & Protocol Manual for
address of a machine. If there is more that details.
one machine connected to the network,
each machine must have a unique number RECOVER
10 SEC
COM ID #
1 • Rotate Time - Used only for sequencing,
see Sequencing & Protocol Manual for
• Communications baud rate - This should details.
always be selected to 9600 baud for all
sequencing modes. It may be lower for ROTATE
slave or monitoring modes. 50
BAUDRATE
• Machine Capacity - Used only for sequenc-
9600
ing, see Sequencing & Protocol Manual for
details.
• Sequence method - This parameter sets
the method used for sequencing. The choic- CAPACITY
es are DISABLED, REMOTE, SLAVE,
HOURS, COM ID#. See the Sequencing & 100
Protocol Manual (P/N 02250057-696) for
details about these modes. • Sequence Hours - Used only for sequenc-
ing, see Sequencing & Protocol Manual for
SEQUENCE details.
HOURS SEQ HRS
• Drain interval - The time between actuation 1000
of the drain valve.
5.4 OPERATING THE COMPRESSOR
DRN INTV Before operating the compressor the operating
parameters must be setup. See the previous sec-
10 MIN
tion on operating parameter setup.
35
Section 5
OPERATION
MANUAL OPERATION MODE the common fault relay, if engaged, and clear any
In this mode the compressor will run indefinitely, as maintenance indicators.
long as temperatures and pressure remain within In automatic mode the compressor can be stopped
the valid operating ranges, and the motor overload manually by pressing “O”. Stopping the compressor
or emergency stop contacts are not tripped. using “O” will put the Supervisor in manual stop
Pressing the “I” will turn on the compressor and put mode.
it in manual mode. If the compressor is already run-
ning, but in automatic mode, pressing “I” will switch Regardless of whether in “automatic” or “manual”
operation to manual. Pressing “I” while already run- mode, control of the load solenoid will be based on
ning in manual mode will cause the Supervisor to the parameters UNLD and LOAD. This operation is
turn off the common fault relay, if engaged, and as follows:
clear any maintenance indicators. P2 > UNLD —> load solenoid turned off
To stop the compressor, press “O”. If the compres- P2 < LOAD —> load solenoid turned on
sor is already off when “O” is pressed, the common POWER FAILURE RESTART
fault relay will be turned off, if engaged, and it will If the restart timer (RST TIME parameter) is dis-
try to clear the alarm and maintenance indicators. abled the compressor will not try to start after a
Regardless of what the compressor is doing, press- power up. If this time is set to a value the machine
ing “O” puts the Supervisor in manual stop mode. will go into standby after power up. When the line
AUTOMATIC OPERATION MODE pressure drops below the load setpoint, the restart
In this mode the compressor will start if line pres- timer will start timing. When the timer expires the
sure (P2) is less than the LOAD parameter. It will machine will start.
stop if the compressor runs unloaded for the num- SEQUENCING MODES
ber of minutes indicated by the UNLD TIM parame- The following is a brief description of sequencing
ter . To put the compressor in automatic mode press modes, for details see the Supervisor II Sequencing
“ ”. If P2 is already less than LOAD the com- & Protocol Manual (P/N 02250057-696).
pressor will start immediately, otherwise the system • DISABLED - Responds to status and
status will indicate STANDBY and the LED marked parameter change messages via the RS485
AUTO will flash. network but will not respond to start, stop,
If the compressor is already running, but in continu- load or unload messages.
• REMOTE - Responds to status and param-
ous mode, pressing “ ” will switch operation to eter change messages but will not respond
automatic. Pressing “ ” while already running in to start, stop, load or unload messages. The
automatic mode will cause the Supervisor to turn off remote inputs and outputs are enabled
COMMON FAULT (K4) May be used to provide remote indication of any pre-alarm,
maintenance or fault shutdown condition.
36
Section 5
OPERATION
(start/stop, load/unload, master/local). maximum pressure (P2) and pressure differen-
• SLAVE - Will respond to all messages, but tial (P2) are correctly programmed.
will not start or load unless commanded to 7. Observe the operating temperature. If the oper-
do so by a message. This mode is used to ating temperature exceeds 235ºF (113ºC), the
control the machine from a master comput- cooling system or installation environment
er. should be checked.
• HOURS - Sends status message about 8. Observe return line sight glasses and mainte-
once a second, starts, loads and unloads nance indicators.
machines based on sequencing hours. 9. Open shut-off valve to service line.
• COM ID # - Sends status message about 10. Reinspect the compressor for temperature and
once a second, starts, loads and unloads leaks the following day.
machines based on machine Com ID#.
5.7 SUBSEQUENT START-UP PROCEDURE
5.6 INITIAL START-UP PROCEDURE On subsequent start-ups, check that the proper
The following procedure should be used to make level is visible in the fluid level sight glass and sim-
the initial start-up of the compressor:
ply press “I” for manual or “ ” for automatic oper-
1. Read the preceding pages of this manual thor-
ation. When the compressor is running, observe the
oughly.
various parameter displays.
2. Be sure that all preparations and checks
5.8 SHUTDOWN PROCEDURE
described in the Installation Section have been
To shut the compressor down, push “O” pad.
made.
3. Crack open the shut off valve to the service line.
4. Start the compressor by pressing the “I” (START)
pad.
5. Check for possible leaks in piping.
6. Slowly close the shut-off valve and check that the
37
NOTES
38
Section 6
MAINTENANCE
6.1 MAINTENANCE INTRODUCTION 6.5 FLUID CHANGE
As you proceed in reading this section, it will be Standard models are filled with Sullube. Sullube
easy to see that Maintenance Program for the air should be changed under the following conditions,
compressor is quite minimal. The Supervisor moni- whichever occur first:
tors the status of the air filter, fluid filter, and sepa- 1. Every 1800 hours.
rator elements. When maintenance to these
devices is required, the Supervisor will display the 2. Once a year.
appropriate maintenance message and flash the 3. As indicated by fluid analysis.
location LED on the graphics map as a visual A fluid sample at every 1000 hours is recommend-
reminder. ed. For a free Sullube analysis, send fluid to:
Dow Chemical
DO NOT remove caps, plugs, and/or other compo-
Lubricant Technology Center
nents when compressor is running or pressur- Building B-1605
ized. Freeport, TX 77541
Stop compressor and relieve all internal pressure To facilitate this, a sample bottle is included with the
before doing so.
compressor.
6.2 DAILY OPERATION 6.6 SEPARATOR MAINTENANCE
Following a routine start, observe the various Replace the separator elements when the separa-
Supervisor displays to check that normal readings tor maintenance message is displayed or after one
are being made - previous records are very helpful (1) year, whichever comes first. The separator ele-
in determining the normalcy of the measurements. ments must be replaced. DO NOT clean the sepa-
These observations should be made during all rator elements.
expected modes of operation (i.e. full load, no-load,
6.7 PARTS REPLACEMENT AND ADJUSTMENT
different line pressures, cooling water tempera-
PROCEDURES
tures, etc.).
FLUID FILTER MAINTENANCE
During the initial start-up or servicing of the pack-
Refer to Figure 6-1. The fluid filter (P/N 02250111-
age, fluid may have to be added to the sump ves-
592) is located schematically between the thermal
sel to restore an adequate level. Frequent fluid
valve on the sump and the oil stop valve on the
additions to maintain said level would be indicative
compressor-mounting bracket. When servicing this
of excessive fluid consumption, and should be
filter, shut the compressor down, make sure all
investigated - see the Troubleshooting Section of
pressure has been released, then follow the
this manual for probable cause and remedy.
instructions below. For element replacement order
6.3 MAINTENANCE AFTER INITIAL 50 HOURS OF kit number 250031-850.
OPERATION
After the initial 50 hours of operation, a few mainte-
nance requirements are needed to rid the system of To minimize the possibility of filter element rup-
any foreign materials which may have accumulated ture, it is important that ONLY replacement ele-
during compressor assembly. Perform the following ments identified with the Sullair name, logo and
appropriate part numbers be used, and that sub-
maintenance operations to prevent unnecessary stitute elements NOT be used, due to the fact that
problems. such filters may have inadequate or questionable
working pressure ratings.
1. Clean the return line strainers.
2. Clean the return line orifices. 1. Unthread the filter canister from the head. A hex
nut is supplied on the bottom of the canister
3. Change the fluid filter elements.
along with the bottom portion of the canister has
4. Clean the control line filters. a rough textured surface. Either can be used to
6.4 MAINTENANCE AS REQUIRED BY LUBRICA- assist in removal of the canister.
TION GUIDE (SECTION 3) 2. Pull the canister away from the filter head. The
1. Drain the sump and change the compressor fluid. filter elements will be attached to the filter head.
2. Replace the main fluid filter element. 3. Separate the element from the filter head.
3. Clean the return line strainers and orifices. 4. Remove the canister seal.
4. Clean or replace the control line filter element.
39
Section 6
MAINTENANCE
Figure 6-1 Main Filter (P/N 02250111-592)
5. Thoroughly clean the filter head and canister in 3. Pull the cover/element assembly out of the hous-
solvent. ing.
6. Lubricate the new seals with the same type of 4. On the inside of the element, you will notice a
fluid used in the compressor and position each lock ring, which fastens the cover to the ele-
seal in its appropriate place. ment. Remove the lock ring and pull the cover
7. Carefully push the element into position under and element apart.
the housing/head. 5. Clean the interior of the housing by using a damp
8. Replace the canister by threading back onto the cloth. DO NOT blow dirt with compressed air.
filter head. 6. Inspect the secondary element and replace if
AIR FILTER MAINTENANCE necessary. This element is NOT cleanable.
Refer to Figure 6-2. Air filter maintenance should 7. To remove the secondary element, unscrew the
be performed when the air filter maintenance mes- secondary restriction indicator from the threaded
sage is displayed. The air filter is equipped with a rod running through the element. Pull the ele-
primary and a secondary element. As previously ment out of the housing.
stated, the Supervisor will alert you as to when the 8. Install the new secondary element and replace
primary element maintenance is necessary. When the restriction indicator.
removing the primary element, always check the
secondary element for visible dirt, grease/oil, or 9. With the secondary element in place, clean or
damage. The secondary element must be changed replace the primary element. Cleaning instruc-
after every sixth primary element inspection. DO tions follow.
NOT clean the secondary element. ELEMENT INSPECTION
AIR FILTER ELEMENT REMOVAL 1. Place a bright light inside the element to inspect
for damage or leak holes. Concentrated light
1. Clean exterior of air filter housing. will shine through the element and disclose any
2. Remove the cover/element assembly by loosen- holes.
ing the wing nut securing it. 2. Inspect all gaskets and gasket contact surfaces
40
Section 6
MAINTENANCE
Figure 6-2 Air Filter Replacement (P/N 048456)
of the housing. Should faulty gaskets be evi- cover (return lines, service lines, etc.) to Allow
dent, correct the condition immediately. lid removal.
3. If the clean element is to be stored for later use, 3. Loosen and remove the eighteen (18) hex head
it must be stored in a clean container. capscrews from the cover/lid plate.
4. After the element has been installed, inspect and
tighten all air inlet connections prior to resuming
To assist with the removal of the tank lid, Sullair
operation. has provided a 1”-8unc nut to the top lid so it can
PRIMARY ELEMENT REPLACEMENT be removed by a 1”-8unc eyebolt (which is avail-
1. Place the element in position on the cover and able from Sullair) or a similar type of lifting device.
replace the locking to secure the cover and ele- 4. Lift the cover/lid plate from the separator.
ment.
5. Remove the primary and secondary separator
2. Install the cover/element assembly and replace elements.
the wing nut. Tighten the wing nut so to seat the
element gasket fully. 6. Scrape the old gasket material from the cover
and flange on the sump being careful not to
AIR/OIL SEPARATOR ELEMENTS REPLACE-
MENT let the scraps fall into the sump.
Refer to Figure 6-3. The separator elements must 7. Inspect the receiver/sump tank for rust, dirt, etc.
be changed when “Separator Maintenance 8. Reinsert the separator elements with gaskets
Required” message is displayed, or once a year, attached into the sump taking care not to dent
whichever occurs first. Order separator elements,
the elements against the tank opening. DO NOT
number 250034-122 (primary) and number 250034-
remove grounding staples from elements.
134 (secondary). Follow the procedure explained
below for separator element replacement. 9. Clean underside of the separator tank cover and
remove any rust. DO NOT remove grounding
1. Relieve all pressure from the separator and all
staples from elements.
compressor lines.
10. Replace the cover plate, washers and cap-
2. Disconnect all piping connected to the separator
screws. Torque to 200ft-lbs. (271Nm).
41
Section 6
MAINTENANCE
Figure 6-3 Separator Element Replacement 1. Disconnect the tubes at the tops of the sight
glass assemblies.
2. Unscrew male connector (for left-side glass), or
the straight thread tube connector (for right-side
glass) from sight glass/orifice blocks.
3. Remove used filter assembly, and replace with
new assembly.
4. Coat/lubricate the O-rings will silicone grease.
5. Reattach the connectors to the sight glass/orifice
blocks.
DIFFERENTIAL PRESSURE REGULATOR
ADJUSTMENT
Refer to Figure 6-5 and 6-6. The differential pres-
sure regulators are adjusted by loosening the
adjusting screw on the end of the cone-shaped
cover of the pressure regulator. When the jam nut
is loose, turn the adjusting screw clockwise to
increase or counterclockwise to decrease the set-
ting.
The reference pressure regulator should be set to
maintain a 60 psig (4.14 bar) downstream pressure
to the inlet poppet valve. The unload pressure reg-
ulator should be set at 175 psig (12.1 bar) to con-
trol the compressor package during unload only.
The inlet poppet valve control pressure regulator
*Primary Replacement Element P/N 250034-122 should be set to control the systems modulation to
**Secondary Replacement Element P/N 250034-134 the service line desired pressure.
11. Reconnect all piping making sure return line Figure 6-4 Oil Return/Sight Glass
tubes extend within 1/4” (6mm) max. above the
bottom of the separator elements. This will
assure proper fluid return flow to the compres-
sor.
12. Check the return line strainer before restarting
the compressor (replacement strainer P/N
02250117-782).
OIL RETURN/SIGHT GLASS MAINTENANCE
Refer to Figure 6-4. The oil return/sight glass sub-
assembly is attached to the separator tank lid. Oil
return/sight glass maintenance should be per-
formed on a routine basis parallel to that of the fluid
filter, or as indicated in the Troubleshooting
Sections (both Supervisor and Maintenance) of this
manual. The maintenance on an oil return/sight
glass is mainly concerned with the condition of the
filter assembly. Order filter assembly no. 02250117-
782, and use the following instructions as a guide.
42
Section 6
MAINTENANCE
Figure 6-5 Pressure Regulator Adjustments
DRIVE COUPLING INSTALLATION AND ALIGN- shafts for dirt and burrs, mount the motor hub and
MENT Table 6-1 Installation Data
Max. Operating Misalignment
Parallel Coupling Angular
Applies to base-mounted compressors and drives Offset Gap
only. Units mounted through common housing inches/mm +.03 in./ .762mm Degrees inches/ mm (I)
are self-aligning. If alignment is suspect, use the .008/ .02 1.38/ 35.0mm .025 .005/ 127mm
following procedure.
Refer to Figures 6-6, 6-7 and 6-8. For coupling (I) Angular misalignment in inches equals maximum A minus mini-
mum B as shown in Figure 6-6. DO NOT exceed values in Table
installation and alignment, the tools required will be
6-1 above.
one set of standard allen wrenches and a dial indi-
cator. If a dial indicator is not available, an alternate
the compressor hub on their respective shafts. It is
method of checking the alignment may be used as
also necessary to check for a proper key fit. Place
a secondary or less desirable technique. This
the keys in position being sure that the end of the
method of checking is done by careful use of a
key is flush with the end of the shaft. Secure the
square or metal straight edge feeler gauge and a
set of inside calipers (see Figure 6-8). Those spec- Figure 6-6 Drive Coupling Alignment
ifications in Table 6-1 which are designated in inch-
es are provided for this method.
For installation and maintenance of the drive cou-
pling, follow the steps explained below.
43
Section 6
MAINTENANCE
Figure 6-7 Drive Coupling corrected by the addition or removal of equal
amounts of shims under the motor feet while hori-
zontal parallel offset is corrected by sliding the
motor sideways.
Angular alignment is indicated by the difference in
indicator readings or by the difference in caliper
measurements (X) (A - B = X). Vertical angular
alignment is achieved by placing shims under the
front or rear motor feet while horizontal angular
alignment is achieved by sliding the motor side-
ways.
44
Section 7
TROUBLESHOOTING
7.1 TROUBLESHOOTING sary damage to the compressor. Always remember
The information contained in the Troubleshooting to:
chart is based upon both actual applied situations a. Check for loose wiring.
and extensive testing at the factory. It contains
symptoms and usual causes for the described prob- b. Check for damaged piping.
lems. However, DO NOT assume that these are the c.Check for parts damaged by heat or an
only problems that may occur. All available data electrical short circuit, usually apparent by
concerning the trouble should be systematically discoloration or a burnt odor.
analyzed before undertaking any repair or compo- Should your problem persist after making the rec-
nent replacement procedures. ommended check, consult your nearest Sullair rep-
A detailed visual inspection is worth performing for resentative or the Sullair Corporation factory.
almost any problems which may prevent unneces-
Motor Starter Overloads Tripped Reset. Should trouble persist, check whether
motor starter contacts are functioning prop-
erly.
Low Incoming Line Voltage Check voltage. Should voltage check low,
consult power company.
COMPRESSOR SHUTS DOWN Loss of Control Voltage Reset. If trouble persists, check that line
pressure does not exceed maximum operat-
ing pressure of the compressor (specified on
nameplate).
45
Section 7
TROUBLESHOOTING
7.2 TROUBLESHOOTING GUIDE(CONTINUED)
SYMPTOM PROBABLE CAUSE REMEDY
COMPRESSOR SHUTS DOWN High Discharge Temperature (Cont.) Cooler plugged; clean tubes. If plugging per-
(CONTINUED) sists, install water conditioner. (water-
cooled).
COMPRESSOR WILL NOT Air Demand is Too Great Check service lines for leaks or open valves.
BUILD UP FULL DISCHARGE
PRESSURE Dirty Air Filter Check the filter indicator and change or clean
element if required.
Defective Minimum Pressure Valve Check that the piston is moving freely.
Inlet Valve Not Opening Completely Check poppet regulating valve; signal must
be 60 psi. Readjust if necessary.
LINE PRESSURE RISES Leak in Control System Causing Loss Check for leaks.
ABOVE P2 PRESSURE of Pressure Signals
EXCESSIVE COMPRESSOR Clogged Return Line or Orifice Clean strainer (screen and o-ring replace-
LUBRICANT CONSUMPTION ment kit available).
46
Section 7
TROUBLESHOOTING
7.2 TROUBLESHOOTING GUIDE (CONTINUED)
SYMPTOM PROBABLE CAUSE REMEDY
EXCESSIVE COMPRESSOR- Clogged Return Line or Orifice (cont.) Clean orifice.
LUBRICANT CONSUMPTION
(CONTINUED) Separator Elements Damaged or Not Change separator elements.
Functioning Properly
Leak in the Lubrication System Check all pipes, connections and compo-
nents.
SUMP PRESSURE RELIEF High Pressure Shutdown Parameter Readjust below pressure relief valve setting.
VALVE OPENS REPEATEDLY is Out of Adjustment
INTERSTAGE PRESSURE Defective Discharge Check Valve Repair or replace (kit available).
RELIEF VALVE OPENS
REPEATEDLY Defective Oil Stop Valve Repair or replace (kit available).
47
NOTES
48
Section 8
ILLUSTRATIONS AND PARTS LIST
8.1 PROCEDURE FOR ORDERING PARTS
Parts should be ordered from the nearest Sullair Representative or the Representative from whom the com-
pressor was purchased. If for any reason parts cannot be obtained in this manner, contact the factory directly
at the addresses, phone or fax numbers below.When ordering parts always indicate the Serial Number of the
compressor. This can be obtained from the Bill of Lading for the compressor or from the Serial Number Plate
located on the compressor.
SULLAIR ASIA, LTD. SULLAIR CORPORATION SULLAIR EUROPE, S.A.
Sullair Road, No. 1 3700 East Michigan Boulevard Zone Des Granges BP 82
Chiwan, Shekou Michigan City, Indiana 46360 U.S.A. 42602 Montbrison Cedex, France
Shenzhen, Guangdong PRV. Telephone: 33-477968470
PRC POST CODE 518068
www.sullair.com
Fax: 33-477968499
Telephone: 1-800-SULLAIR (U.S.A. Only)
Telephone: 755-6851686 www.sullaireurope.com
or 1-219-879-5451
Fax: 755-6853473
Fax: (219) 874-1273
www.sullair-asia.com
PARTS DEPARTMENT
Fax: (219) 874-1835
www.sullair.com/parts.shtm
SERVICE DEPARTMENT
Fax: (219) 874-1205
www.sullaircompressors.com
49
Section 8
ILLUSTRATIONS AND PARTS LIST
8.2 SPARE PARTS LIST- LS20T (200-300HP) (CONTINUED)
DESCRIPTION KIT NUMBER QTY
Replacement drive-coupling element (<=300hp) (I)(II) 02250075-399 1
Repair kit for thermal valve 250016-929 1
Repair kit for shaft seal 001811A 1
Repair kit for discharge check valve assembly 016732B 606208-001 1
Sullube fluid (5-gal can) 250022-669 30-gal
Sullube fluid (55-gal drum) (I) 250022-670 30-gal
50
NOTES
51
Section 8
ILLUSTRATIONS AND PARTS LIST
8.3 MOTOR, FRAME, COMPRESSOR AND PARTS
02250133-520R00
52
Section 8
ILLUSTRATIONS AND PARTS LIST
8.3 MOTOR, FRAME, COMPRESSOR AND PARTS
key part
number description number quantity
(I) For maintenance on drive coupling element, order drive coupling replacement no. 02250075-399
(<=300hp). For machines greater than 300HP, consult factory.
(II) There is an exchange program whereby a remanufactured compressor unit can be obtained from
Sullair distributors or the factory at less cost than the owner could repair the unit. For information
regarding the unit exchange program, contact your nearest Sullair representative or the Sullair
Corporation.
The shaft seal is not considered part of the compressor unit in regard to the two year warranty.
The normal Sullair parts warranty applies. For shaft seal repairs order repair kit no. 001811A.
(III) Motor may vary. Consult factory with machine serial number.
PLEASE NOTE: WHEN ORDERING PARTS, INDICATE THE SERIAL NUMBER OF COMPRESSOR
53
Section 8
ILLUSTRATIONS AND PARTS LIST
8.4 AIR INLET SYSTEM
02250133-521R00
54
Section 8
ILLUSTRATIONS AND PARTS LIST
8.4 AIR INLET SYSTEM
key part
number description number quantity
(I) For maintenance on air inlet valve assembly no. 02250054-763, order repair kit no. 02250112-533, or
rebuild kit no. 02250112-534.
(II) For maintenance on air filter no. 048456, order primary replacement element no. 048462, and secondary
replacement element no. 048463.
(III) When performing maintenance on the inlet valve assembly, if required, order gasket no. 242437-012
(quantity of 2).
PLEASE NOTE: WHEN ORDERING PARTS, INDICATE THE SERIAL NUMBER OF COMPRESSOR
55
Section 8
ILLUSTRATIONS AND PARTS LIST
8.4 AIR INLET SYSTEM
02250133-521R00
56
Section 8
ILLUSTRATIONS AND PARTS LIST
8.4 AIR INLET SYSTEM (CONTINUED)
key part
number description number quantity
PLEASE NOTE: WHEN ORDERING PARTS, INDICATE THE SERIAL NUMBER OF COMPRESSOR
57
Section 8
ILLUSTRATIONS AND PARTS LIST
8.5 FLUID COOLING SYSTEM- AIR-COOLED
02250134-189R00
58
Section 8
ILLUSTRATIONS AND PARTS LIST
8.5 FLUID COOLING SYSTEM- AIR-COOLED
key part
number description number quantity
PLEASE NOTE: WHEN ORDERING PARTS, INDICATE THE SERIAL NUMBER OF COMPRESSOR
59
Section 8
ILLUSTRATIONS AND PARTS LIST
8.6 WATER COOLING SYSTEM- WATER-COOLED
02250133-525R00
60
Section 8
ILLUSTRATIONS AND PARTS LIST
8.6 WATER COOLING SYSTEM- WATER-COOLED
key part
number description number quantity
PLEASE NOTE: WHEN ORDERING PARTS, INDICATE THE SERIAL NUMBER OF COMPRESSOR
61
Section 8
ILLUSTRATIONS AND PARTS LIST
8.7 AIR PIPING SYSTEM- AIR-COOLED
02250135-563R00
62
Section 8
ILLUSTRATIONS AND PARTS LIST
8.7 AIR PIPING SYSTEM- AIR-COOLED
key part
number description number quantity
PLEASE NOTE: WHEN ORDERING PARTS, INDICATE THE SERIAL NUMBER OF COMPRESSOR
63
Section 8
ILLUSTRATIONS AND PARTS LIST
8.8 AIR PIPING SYTEM- WATER-COOLED
02250133-523R00
64
Section 8
ILLUSTRATIONS AND PARTS LIST
8.8 AIR PIPING SYTEM- WATER-COOLED
key part
number description number quantity
(I) For maintenance on minimum pressure/check valve no. 250022-735, order repair kit no. 250022-736.
PLEASE NOTE: WHEN ORDERING PARTS, INDICATE THE SERIAL NUMBER OF COMPRESSOR
65
Section 8
ILLUSTRATIONS AND PARTS LIST
8.9 FLUID PIPING SYSTEM- AIR-COOLED
02250135-564R00
66
Section 8
ILLUSTRATIONS AND PARTS LIST
8.9 FLUID PIPING SYSTEM- AIR-COOLED
key part
number description number quantity
(I) For maintenance on fluid filter assembly no. 02250111-592, order replacement element no. 250031-
850.
(II) For maintenance on thermal valve assembly, order repair kit no. 250016-929.
(III) For maintenance on fluid stop valve no. 250041-069, order repair kit no. 02250051-747.
PLEASE NOTE: WHEN ORDERING PARTS, INDICATE THE SERIAL NUMBER OF COMPRESSOR
67
Section 8
ILLUSTRATIONS AND PARTS LIST
8.9 FLUID PIPING SYSTEM- AIR-COOLED
02250135-564R00
68
Section 8
ILLUSTRATIONS AND PARTS LIST
8.9 FLUID PIPING SYSTEM- AIR-COOLED (CONTINUED)
key part
number description number quantity
PLEASE NOTE: WHEN ORDERING PARTS, INDICATE THE SERIAL NUMBER OF COMPRESSOR
69
Section 8
ILLUSTRATIONS AND PARTS LIST
8.10 FLUID PIPING SYSTEM- WATER-COOLED
02250133-524R00
70
Section 8
ILLUSTRATIONS AND PARTS LIST
8.10 FLUID PIPING SYSTEM- WATER-COOLED
key part
number description number quantity
(I) For maintenance on fluid filter assembly no. 02250111-592, order replacement element no. 250031-
850.
(II) For maintenance on thermal valve assembly, order repair kit no. 250016-929.
(III) For maintenance on fluid stop valve no. 250041-069, order repair kit no. 02250051-747.
PLEASE NOTE: WHEN ORDERING PARTS, INDICATE THE SERIAL NUMBER OF COMPRESSOR
71
Section 8
ILLUSTRATIONS AND PARTS LIST
8.10 FLUID PIPING SYSTEM- WATER-COOLED
02250133-524R00
72
Section 8
ILLUSTRATIONS AND PARTS LIST
8.10 FLUID PIPING SYSTEM- WATER-COOLED (CONTINUED)
key part
number description number quantity
PLEASE NOTE: WHEN ORDERING PARTS, INDICATE THE SERIAL NUMBER OF COMPRESSOR
73
Section 8
ILLUSTRATIONS AND PARTS LIST
8.11 WATER PIPING SYSTEM- WATER-COOLED
02250133-526R00
74
Section 8
ILLUSTRATIONS AND PARTS LIST
8.11 WATER PIPING SYSTEM- WATER-COOLED
key part
number description number quantity
PLEASE NOTE: WHEN ORDERING PARTS, INDICATE THE SERIAL NUMBER OF COMPRESSOR
75
Section 8
ILLUSTRATIONS AND PARTS LIST
8.12 DISCHARGE SYSTEM
02250133-522R01
76
Section 8
ILLUSTRATIONS AND PARTS LIST
8.12 DISCHARGE SYSTEM
key part
number description number quantity
(I) For maintenance on valve assembly no. 016732B, order repair kit no. 606208-001.
(II) For maintenance on blowdown valve no. 045116, order repair kit no. 042246.
(III) For maintenance on primary separator element no. 250034-121, order replacement element no.
250034-122.
(IV) For maintenance on secondary separator element no. 250034-133, order replacement element no.
250034-134.
PLEASE NOTE: WHEN ORDERING PARTS, INDICATE THE SERIAL NUMBER OF COMPRESSOR
77
Section 8
ILLUSTRATIONS AND PARTS LIST
8.12 DISCHARGE SYSTEM
02250133-522R01
78
Section 8
ILLUSTRATIONS AND PARTS LIST
8.12 DISCHARGE SYSTEM (CONTINUED)
key part
number description number quantity
PLEASE NOTE: WHEN ORDERING PARTS, INDICATE THE SERIAL NUMBER OF COMPRESSOR
79
Section 8
ILLUSTRATIONS AND PARTS LIST
8.13 CONTROL/START SYSTEM
02250133-528R00
80
Section 8
ILLUSTRATIONS AND PARTS LIST
8.13 CONTROL/START SYSTEM
key part
number description number quantity
(I) For maintenance on filter no. 02250058-442, order replacement element no. 02250058-441.
(II) For maintenance on solenoid valve no. 022500125-657, order repair kit no. 02250125-829, and replace-
ment coil no. 02250125-861.
(III) For maintenance on pressure regulator valve no. 045099, order repair kit no. 048409.
(IV) For maintenance on pressure regulator valve no. 048059, order repair kit no. 048409.
(V) For maintenance on pressure regulator valve no. 048354, order repair kit no. 048410.
PLEASE NOTE: WHEN ORDERING PARTS, INDICATE THE SERIAL NUMBER OF COMPRESSOR
81
Section 8
ILLUSTRATIONS AND PARTS LIST
8.13 CONTROL/START SYSTEM
02250133-528R00
82
Section 8
ILLUSTRATIONS AND PARTS LIST
8.13 CONTROL/START SYSTEM (CONTINUED)
key part
number description number quantity
(VI) For maintenance on solenoid valve no. 407390, order repair kit no. 02250053-830, and replacement
coil no. 250031-431.
(VII) Due to available custom starters, part numbers may vary. Consult factory to determine correct starter.
PLEASE NOTE: WHEN ORDERING PARTS, INDICATE THE SERIAL NUMBER OF COMPRESSOR
83
Section 8
ILLUSTRATIONS AND PARTS LIST
8.14 CONTROL PANEL
02250137-724R01
84
Section 8
ILLUSTRATIONS AND PARTS LIST
8.14 CONTROL PANEL
key part
number description number quantity
(I) For detail of Supervisor II panel decal, see Figure 2-6, Supervisor II Panel in Section 2, Description.
PLEASE NOTE: WHEN ORDERING PARTS, INDICATE THE SERIAL NUMBER OF COMPRESSOR
85
Section 8
ILLUSTRATIONS AND PARTS LIST
8.15 ENCLOSURE AND ENCLOSURE DECALS
86
Section 8
ILLUSTRATIONS AND PARTS LIST
8.15 ENCLOSURE AND ENCLOSURE DECALS
The Enclosure Section was not available at time of print. For breakdown of Enclosure assemblies for
air-cooled and water-cooled models, please consult factory.
key part
number description number quantity
PLEASE NOTE: WHEN ORDERING PARTS, INDICATE THE SERIAL NUMBER OF COMPRESSOR
87
Section 8
ILLUSTRATIONS AND PARTS LIST
8.16 DECAL GROUP
88
Section 8
ILLUSTRATIONS AND PARTS LIST
8.16 DECAL GROUP
key part
number description number quantity
PLEASE NOTE: WHEN ORDERING PARTS, INDICATE THE SERIAL NUMBER OF COMPRESSOR
89
Section 8
ILLUSTRATIONS AND PARTS LIST
8.16 DECAL GROUP
90
Section 8
ILLUSTRATIONS AND PARTS LIST
8.16 DECAL GROUP (CONTINUED)
key part
number description number quantity
PLEASE NOTE: WHEN ORDERING PARTS, INDICATE THE SERIAL NUMBER OF COMPRESSOR
91
Section 8
ILLUSTRATIONS AND PARTS LIST
8.16 DECAL GROUP
92
Section 8
ILLUSTRATIONS AND PARTS LIST
8.16 DECAL GROUP (CONTINUED)
key part
number description number quantity
PLEASE NOTE: WHEN ORDERING PARTS, INDICATE THE SERIAL NUMBER OF COMPRESSOR
93
Section 8
ILLUSTRATIONS AND PARTS LIST
8.17 DECAL LOCATIONS- OPEN AIR-COOLED
94
Section 8
ILLUSTRATIONS AND PARTS LIST
8.17 DECAL LOCATIONS- OPEN AIR-COOLED
key part
number description number quantity
PLEASE NOTE: WHEN ORDERING PARTS, INDICATE THE SERIAL NUMBER OF COMPRESSOR
95
Section 8
ILLUSTRATIONS AND PARTS LIST
8.18 DECAL LOCATIONS- OPEN WATER-COOLED
96
Section 8
ILLUSTRATIONS AND PARTS LIST
8.18 DECAL LOCATIONS- OPEN WATER-COOLED
key part
number description number quantity
PLEASE NOTE: WHEN ORDERING PARTS, INDICATE THE SERIAL NUMBER OF COMPRESSOR
97
Section 8
ILLUSTRATIONS AND PARTS LIST
8.19 DECAL LOCATIONS- CONTROL BOX
98
Section 8
ILLUSTRATIONS AND PARTS LIST
8.19 DECAL LOCATIONS- CONTROL BOX
key part
number description number quantity
(I) Due to custom voltage requests, voltage decal may vary. For positive identification of machine volt-
age decal, consult Sullair Factory with serial number of compressor.
PLEASE NOTE: WHEN ORDERING PARTS, INDICATE THE SERIAL NUMBER OF COMPRESSOR
99
Section 8
ILLUSTRATIONS AND PARTS LIST
8.20 WIRING DIAGRAM- LS20T AIR-COOLED
02250137-716R00
100
Section 8
ILLUSTRATIONS AND PARTS LIST
8.21 WIRING DIAGRAM- LS20T WATER-COOLED
02250133-440R00
101
NOTES
102
WORLDWIDE SALES AND SERVICE
SULLAIR CORPORATION
3700 East Michigan Boulevard
Michigan City, Indiana 46360 U.S.A.
www.sullair.com
Telephone: 1-800-SULLAIR (U.S.A. Only)
or 1-219-879-5451
Fax: (219) 874-1273
PARTS DEPARTMENT
Fax: (219) 874-1835
www.sullair.com/parts.shtm
SERVICE DEPARTMENT
Fax: (219) 874-1205
www.sullaircompressors.com