Sei sulla pagina 1di 173

GOVT.

OF MADHAYA PRADESH
PANCHAYAT & RURAL DEVELOPMENT DEPARTMENT
RURAL ENGINEERING SERVICE

SCHEDULE OF RATES FOR


CONSTRUCTION WORKS
(FOR CONTRACT WORK)

Inforce From 01 November 2017


Issued By
Engineer in Chief
Rural Engineering Services
Bhopal (M.P.)
\ o-rqff,q sgq sTfuddr
qrfrq qiBr+t €qI, qtqrtsr
"fr" fti-[, ffE dd, ftItqfqd lTqq, fiqrd
eincres@mp.gov.in E 0755 -2551398

5A / zz /fr.-to /urwfi / tz, dqrd, frqi.F: $o 7p 7r


// tt qrtzr
{tGrr yrrct"r d ffq ci-jqn urfrur qiM +qr d FHIUT o-rql tg fuqTo
01.02.2016 t q.Trqpftd g-qfua e< el-Js[fr ih-r csr aq *i d qrqn q-g t-tr
qcrcqr d ergo-v grfreTq. oq fr+nq o1 Tfi-q <t 3n-g{fr qft qtt qr. sS t t s} fu
fu{ro 01.1i.2017 d qqT-aqfi-d *fr r Eq-ft1 qfr f,{+Tl-rf at ie{{|{e
www.mppanchavatdarpan.gov.in d Tffiq qiffi +4|- t-€H ti sqe-er.i't

g.orio,-S0 sf
^ f\-J
/ zz /fu.-to /rwrt / n,
qfuftTfu,-
l. ft-q q+fuq qr+fiq ri4-{d gq rffiq fufit-rr frqrq t

2. qufglox Tflfu-w
qeqq-erT I

3. 3Tq.{ gs rrfuq qq repT yrl{lq q4-{f, 1'q il-ftuT ft-fl-fl ftqq I

4. HF"l-q, qq q-+qT yrNFI trqa \'q il-ftq fuo-rs furrrq t

5. 3TEzrd (qrqw) q|cftrI $il{ ffqtr+gl I

6. qgs erft=q-dr ffqtrivT urftut s€cn fuo-ls wtro-<uv7fro Fmfut fr,Twlq-f,


${ililq A+rmZelo lsnaq qTM fu}ilrf qtqregl q)ql-d I

7. o-+{d{ (w-t:c) qqnder I

8. T€q 3TR{idr, ilfr'T qiM


+il ,nqrd, q-q-dgq, Tq rilfu{i I

s. 3Tsft&TUT u-fr (u+w) ilfrq qiffi tfl qsqtr+vt t

ro.odqraq q* (er-w) ilftq qiffi +qr ff4qeq qfi etri rp++f gq


silcrgqo orffi & nRd fu{r6 01.11.2017 + {{,fr H{fi-dq rfi-{ et ergqfr
(fuqro 01.11.2012 t m{) d ernm w fr d-qR frtq \il-d ngn nrft frfrErd
rqft <q Gr-Jq$ d enenq w erriBo at q-i t qd rS-qd Xd <-qt w
qar ckT vi-i t

{^,'*
oTR?idr
qiBr+t +qr
rArT .frqrd
FirstScheduleofRates(SoR)forRuralEngineeringServicesforimplernentationof
1995' lt was subsequently revised few
works done by the Departrnent was issued in october
Since then there has been lot of changes
times and last revision was effective w.e.f . 01.02.2016.
keep pace with the movement of
in the cost of construction material and labour' In order to
SOR has been proposed' The present SOR is an outcome
of inputs from
market price this new
and labour. we have also included
field functionaries on various rates of materials, machinery
about 1685 items which were not envisaged at the
time of preparation of SoR Software in year
rate analysis of such items was not available in
2003 have also been included. As comprehensive
PWD SOR and other relevant SOR' These items
the software such items have been adopted from
have been included in ChaPter 25'
WhereveranyreferenceismadetoanylndianStandard'itshallbetakenasreferenceto
ln the event of any variation between the
the Iatest edition with all amendrnents issued thereto'
over the
pwD nomenclature (adopted) and the Indian Standard, the former shall take precedence
latter.
PreparationandrevisionofanySchedu|eofRatesisahighlytechnicalandarduoustask
S. K'
and require lot of efforts to accomprish. I
wish to prace on record the efforts made by Shri
Satish Tiwari E,E (lncharge), Shri Ravi
Khare SE, Shri p.K. Nigam CE (lncharge), Shri
chachane AE, Smt. Noopur vishwakarma S/E,
Shri P'c' Bagri S/E and all engineers of RES
considerabry to this job. l would like to thank
famiry from fierd and office who have contributed
suggestions' This new SOR would be
all field engineers who provided useful feedback and
effective from l't Nov' 2017'
manr rn the snhe^rrl re will be highly
Suggestions,ifany,forimprovementtotheScheduleofRatesatanyttn
appreciated.

Bhopal
Dated 30'n Oct. 20 | 7

(P.D. Khaira)
Engineer in Chief
Rural Engineering Service
MadhYa Pradesh
INDEX
CHAPTER CHAPTER NAME PAGE No
00 GENERAL 1-6
01 JUNGLE CLEARANCE 7-8
02 MORTARS 9-10
03 EXCAVATION 11-15
04 FILLING FOUNDATION, CONCRETE WORK 16-19
05 STONE MASONRY 20-22
06 BRICK MASONRY 23-25
07 WOODWORK AND JOINERY 26-33
08 CEILING AND WALL BOARDING 34
09 IRONWORK 35-40
10 PLASTERING AND POINTING 41-46
11 ROOFING 47-50
12 PAVING, PITCHING AND FLOORING 51-56
13 PAINTING, WASHING AND DISTEMPERING 57-63
14 REPAIR TO BUILDING WORK 64-65
15 DISMANTLING AND DEMOLISHING 66-68
16 MISCELLANEOUS -I 69-70
17 SURVEY AND INVESTIGATION 71-72
18 COLLECTION OF MATERIALS 73-75
19 TRANSPORTATION OF MATERIALS 76-79
20 ROADWORK 80-86
21 WATER SUPPLY & FITTINGS 87-94
22 SEWAGE, DRAINAGE AND SANITARY FITTINGS 95-101
23 SPECIAL ITEMS OF EARTH/MASONRY DAM AND 102-103
CANALS
24 WELL EXCAVATION 104
25 MISCELLANEOUS - II 105-132
26 ANNEXURE – 1 TO 13
27 APPENDIX – A TO G
Page 1 of 132
00 - GENERAL

0.1 GENERAL INSTRUCTIONS :

0.1.01 In the absence of any stipulations to the contrary, unit rate for various items of works
are for completing works to the requirements of the specifications including full
compensation for all operations & inclusive of all labour, materials, royalties, lease rent,
wastages, temporary work, plant, equipment, over head charges and profit, unless specified
otherwise.

0.1.02 The mode of measurements shall be as per provisions content in the relevant chapters
and items of the specifications, unless specified otherwise.

0.1.03 The rates include the element of higher and running charges of all types of plants,
machinery and equipment, required to complete the work, unless specified otherwise. The
rates provided in this schedule of rates include, cost, lead, lift of all materials required for
execution of works inclusive of all charges like duties, octroi, tax, royalty, insurance etc. as
may be applicable, all labour, all lead and lift (unless otherwise specifically provided for)
including performance all workmanship, provision for erection and removal of centering
forms scaffolding, benching, ladders, templates, tools and plants and all other applications
etc. required for the proper execution of work unless otherwise specified. Provisions for
covering etc. necessary to protect the work / structure from inclement weather etc. and
damage arising from falling materials or other cause such as rain, fire etc. shall be
contractors responsibility. Rates are also inclusive of curing wherever required including
arrangement of water and its lead or lift whatsoever.

0.1.04 The labour only provided in the schedule of rates includes the cost of all labour
including necessary machine, tools, scaffolding, handling of materials at site of works, all
workmanship and including the cost of scaffolding, curing, any sundry material like nails,
spikes, water etc. and as detailed above, but does not include the cost of main material,
which means materials shall be made available at or near the site of work. The rate includes
provision of handling, storing under cover as required.

0.1.05 The rates also include the element of testing of samples of various materials brought
by the contractor for use on the work, as well as other necessary tests for items of work as
stipulated in the specifications. Frequency of such tests to be carried out must not be less
than the prescribed frequencies. Copies of registers, containing records of tests shall have to
be presented along with running account bills. Register (original) shall have to be submitted
along with the final bill. Tests shall have to be conducted by the contractor's Engineer under
the supervision of the Engineer-in-charge or his authorized representatives. The contractor
shall have to establish a field laboratory at the site of work, if the amount of contract exceeds
Rs. 25.00 lacs. In other cases where amount of contract is between 5 to 25 lakhs, testing of
construction materials should be got done from any of the tests laboratories of the various
Govt. Departments, Government/Semi Govt. under takings and Technical Institutes,
Engineering College, Polytechnic, I.T.I. etc.

(a) The work should not be accepted in any case, if the contractor fails to observe the
instructions of the department, regarding testing of materials.
(b) Before making any payment, it will bet the responsibility of the officers making payment
to assure that all tests as per prescribed frequencies, have been carried out, and found as per

RES - NIC MPSU 00 - GENERAL Page 1 of 6


Page 2 of 132
00 - GENERAL

requirement.
(c) If tests are not conducted to the prescribed frequency, the Engineer in Charge should
reject that part of the work.

0.1.06 All material shall conform to the relevant Indian Standard Specification prevailing on
the date of issue of notice inviting tender. All materials before use in work shall require
approval of the Engineer in Charge, who will get them tested sampled as per relevant IS
Code 1S:5454:1978 at contractor's cost and samples so approved be kept in the office of the
concerned sub divisional officer till finalization of the work.

0.1.07 It will not be obligatory on the part of Engineer in charge to provide any assistance in
obtaining of lease/permits for extraction of minor minerals. The contractor will not be entitle
to any excuse, whatsoever, on account of any delays in obtaining minor minerals to be used
on the work.

0.1.08 Not withstanding any thing to the contrary, aggregates to be used for all cement
concrete items shall be crushed in the mechanical crushers. All concrete shall have to be
mixed in power driven mixtures having hoppers and capacity of mixing concrete mix of
atleast one bag of cement.

0.1.09 Nothing extra shall be payable on account of use of Narmada sand or sand brought
from any other quarry / river. Sand should conform to the requirements of IS: 1542 and IS:
2166 for using it in construction work.

0.1.10 When cement is used for mortar/volumetric mix etc. batch of one bag cement or its
multiples shall be mixed and the measurement of box for metal, sand to be of 35 litres or
multiples of it (convenient box size 40x35x25 cm). For design mix concrete batching shall
be done by weight.

0.1.11 Rates in this S.O.R. would also apply for works (Administrative approval upto Rs.
2.00 Lakhs) on piece work/work order system. Rates payable for any item of work proposed
to be done under this system may either be at par or below the rates in this S.O.R.

0.1.12 Rubble available from excavation of hard rock shall be property of the contractor
subject to recovery of Rs. 150 per cum of the quantity of the rock excavated.

0.1.13 The contractor shall have to provide a ruled duplicate register at site named "Site
order book". It shall be in the custody of departmental supervisory staff. The
Engineer-in-Charge or his authorized representative may record his instructions in this book,
which shall be noted by the contractor or his authorized representative for compliance.

0.1.14 Teak wood shall not be used in any building work unless specific sanction of the State
Government is obtained.

(a) Provision of teak wood shall not be made in any of the estimate without prior sanction of
the State Government.

0.1.15 Where contract provides for cement to be arranged by the contractor himself, only ISI

RES - NIC MPSU 00 - GENERAL Page 2 of 6


Page 3 of 132
00 - GENERAL

mark cement of relevant IS specifications shall be allowed to be used in the work subject to
the following tests. The arrangement for necessary equipment and testing shall have to be
made by the contractor himself at site, to be decided by the Engineer-in-Charge. All
expanses shall be borne by the contractor. Any lot of cement brought to site by the
contractor, would be permitted to be used in the work only after the satisfactory results of the
tests, under the supervision of the Engineer-in-Charge or his authorized representatives. The
record of the tests result shall be maintained in the register referred in subsequent para.
a. Test for initial & final setting time as per IS: 3536-1996 1 Test for 10 tonnes or part
thereof upto 10 tonnes.
b. Test for determination of compressive strength of cement as per IS: 3536-1996 1 Test for
50 tonnes or part thereof upto 10 tonnes.

0.1.16 A duplicate register as per format here under shall be maintained at site of work.
Extract certified copies of the entries for each month shall be submitted to the
Engineer-in-Charge by the contactor. The original register shall also be submitted to the
Engineer-in-Charge on completion of the work by the contractor.
----------------------------------------------------------------------------------------------------------------
S.No. Date of No. Name Signature Signature Result of Result of Remark
receipt of and of of authorised test for of tests
of cement bags address contractor representative initial for
of firms, or his of Engineer- and final compressive
from authorised in-Charge setting strenght
representative time of cement
----------------------------------------------------------------------------------------------------------------

0.1.17 When the strength of concrete required is upto M-20, then OPC confirming to IS
269-1989 or PPC confirming to IS : 1498-1976 may be used.

0.1.18 When the strength of concrete required is more than M-20 but upto M-30, then OPC
confirming to IS : 8112 - 1989 shall be used.

0.1.19 Nominal mix would be adopted for cement concrete M-7.5, M-10, M-15 and M-20.
Design mix shall have to be adopted for concrete of higher strengths.

0.1.20 As regard to steel reinforcement;

a) Mild steel and medium tensile steel bars shall conform to IS : 432 (Part-I).
b) Hot rolled deformed bars shall conform to IS : 1139.
c) Cold Twisted bars shall conform to IS : 1786.
d) Hard drawn steel wire fabric shall conform to IS : 1566 and
e) Rolled steel made from structural steel shall conform to IS : 226.

0.1.21 All reinforcement shall be free from loose mill scales, loose rust and coats of paints,
oil, mud or other coating which may destroy or reduce bond.

0.1.22 The contractor shall have to produce Test Certificate in the proforma prescribed
approved by BIS from the manufacturer for every batch of steel brought to site of work.

RES - NIC MPSU 00 - GENERAL Page 3 of 6


Page 4 of 132
00 - GENERAL

0.1.23 Only such steel as is obtained from main producers of steel e.g. SAIL, IISCO,
TISCO or such steel rolling mills as are having licence from the B.I.S to manufacture such
steel for reinforcements, shall to be allowed to be used in the work.

0.1.24 The rates for various items in this SOR are subject to stipulations in these "General
Notes".

0.1.25 Items not included in this SOR shall neither be provided in any estimate nor executed
without express prior permission of the Chief Engineer even though shown in the drawings
prepared by the Chief Architect or any Consulting Architect. If any new or modified item is
proposed to be provided in any estimate or intended to be executed in any work, proposals
with full justification thereof along with financial implication must be submitted to the Chief
Engineer for obtaining prior approval.

0.1.26 In case of any contradiction in the provisions of the specifications and the SOR, the
provisions of the latter would take precedence.

0.1.27 The rates as given in this schedule for all items are final, binding and conclusive. In
case of doubt and printing mistakes if any, the decision of the Chief Engineer will be final
and binding.

0.1.28 In the interpretation of description of items or rates of the schedule of rates and
specification, the decision of the Chief Engineer shall be final and binding.

0.2 DEFINITIONS :
a) Specifications would refer to the Central Public Works Department (CPWD)
specifications as applicable as on date.
b) Engineer-in-charge would refer to the Executive Engineer of the Rural Engineering
Services Division for the time being. It would also refer to the "Engineer" mentioned in the
aforesaid specifications.
c) B.I.S. would refer to Bureau of Indian Standards.

The following terms and expressions in this schedule shall have the meaning or implication
hereby assigned to them unless otherwise specified elsewhere.
0.2.01. Contractor - The 'contractor' shall mean the individual or firm or company whether
incorporated or not undertaking the works and shall include the legal personal
representatives of such individual of the persons composing such firm or company, or the
successors of such individual or firm or company and the permitted assignees of such
individual or firm or company.
0.2.02. Engineer-in-charge - The 'Engineer-in-charge' means the Executive Engineer who
shall supervise and be in-charge of the work and who shall sign the contract on behalf of the
Governor.
0.2.03. Site- The 'Site' shall mean the land/or other places on. in. into or through which the
work is to be executed or any adjacent land, path or street through which the work to be
executed or any adjacent land, path or street which may be allotted or used for purpose of
carrying out the work.
0.2.04 Store - The 'store' shall mean the place of issue of materials included in the
appropriate schedule for issue by the R.E.S. In all other cases ' store' shall mean any R.E.S.

RES - NIC MPSU 00 - GENERAL Page 4 of 6


Page 5 of 132
00 - GENERAL

store in the district.


0.2.05. IS- The standards, specification and code of Practices issued by the Bureau of Indian
Standards.
0.2.06 Best- The word 'Best' when used shall mean that in the opinion of the Engineer- in-
charge, there is no superior material/ article and workmanship obtainable in the market and
trade respectively. As for as possible the standard required shall be specified in preference to
the word 'Best' .
0.2.07. Department- ' Department' shall mean Rural Engineering Services under the control
of Rural Development Department of Government of Madhya Pradesh.
0.2.08 MOST - MOST shall mean ministry of surface transport (Road wing) Govt. of India.
Publication "Specification of Road and Bridge Works" (Fifth Revision) 2004.
0.2.09. S.R.R.- S.R.R.shall mean publication of I.R.C. (Ministry of Rural Development)
named as "Specification for Rural Roads" 2004
0.2.10. S.P.20 - S.P.20 means the publication of I.R.C. named as "Special Publication 20 -
Rural Road Manual 2002". Also IRC publication means any relevent Indian road Congress
publications for the subject.

0.3. FLOORS AND LEVELS :


0.3.01. Buildings :
(a) Floor 1 is the lowest floor above the ground level in the building unless otherwise
specified in a particular case. The floors above floor 1 shall be numbered in sequence as
floor 2, floor 3 and so on. The number shall increase upwards.
(b) Floor Level - For Floor 1, top level of finished floor shall be the floor level and for all
other floors above floor 1, top level of the structural slabs shall be the floor level .
(c) Plinth Level - Floor 1 level or 1.2 m above the ground level whichever is lower shall be
the plinth level.
0.4. SPECIAL STRUCTURES :
For structures like retaining walls, wing walls, chimneys, over head reservoirs/tanks and
other elevated structures, where elevations/ heights above a defined datum level have not
been specified and identification of floor cannot be done as in case of buildings, levels, at 1.2
m above the ground level shall be the floor 1 level as well as plinth level. Level at height of
3.5 m above floor 1 level will be reckoned as floor 2 level and level at a height of 3.5 m
above the floor level will be floor 3 level and so on . Where the total height above the floor 1
level is not a whole number multiple of 3.5 meters, top most floor level shall the next in
sequence to the floor level below even if the difference in height between the two upper most
floor levels is less than 3.5 meters.
0.5 FOUNDATION AND PLINTH :
The work in foundation and plinth shall include -
(a) For buildings - All works upto 1.2 meters above ground level or upto floor 1 level
whichever is lower.
(b) For abutments, piers and well staining - All works upto 1.2 m above the bed level.
(c) For retaining walls, wing walls, compound walls, chimneys, over head reservoirs/ tanks
and other elevated structures All works upto 1.2 meters above the ground level.
(d) For reservoirs/tanks (other than overhead reservoirs/tanks) - All works upto 1.2 meters
above the ground level.
(e) For basements - All works upto 1.2 meters above ground level or upto floor 1 level
whichever is lower.
0.6 MEASUREMENTS :

RES - NIC MPSU 00 - GENERAL Page 5 of 6


Page 6 of 132
00 - GENERAL

0.6.01. In booking dimensions, the order shall be consistent and the sequence of length, the
width and height or depth or thickness.
0.6.02. Rounding off - Rounding off where required shall be done in accordance with IS:
2-1960. The number of significant places rounded in the round off value should be as
specified.
0.7. SAFETY IN CONSTRUCTION :
0.7.01. The Panchayat and Implementing Agency shall employ only such methods of
construction, tools and plant as are appropriate for the type of work or as approved by
Engineer- in- charge in writing.
0.7.02. The Panchayat and Implementing Agency shall take all precautions and measures to
ensure safety of work and workman and shall be fully responsible for the same . Safety
pertaining to construction works such as excavation, centring and shuttering, trenching,
blasting, demolition, electric connections, scaffolds, ladders, working platforms, gangway,
mixing of bituminous materials, electric and gas welding, use of hoisting and construction
machinery shall be governed by CPWD Safety code, relevant safety codes and the directions
of Engineer-in-charge.
0.8. ABBREVIATIONS:
The following abbreviations, wherever they appear in the schedule of rates, shall have the
meaning of implications hereby assigned to them.
AC Asbestos Cement ASTM American Society for testing materials
BC Black cotton BM Bench Mark
BWG British Wire Gauge Bt Black Trap
C Degree centigrade
temperature CC Cement Concrete
CG Centre of gravity CGS Corrugated Galvanised sheet
CI Cast iron CL Centre line
cm Centimetre CM Cement mortar
CR Coursed rubble cucm Cubic centimetre
cum Cubic metre cumec (s) Cubic metre per second (s)
Dia Diameter DRR Diesel road roller
D\S Downstream etc. Etcetra
e.g. For example ERW Electric resistance welded
E\ W Earth work GI Galvanised iron
KVA Kilo volt ampere LM Lime mortar
LWL Low water level m Metre
MDD Maximum dry density mm Millimetre
MS Mild steel MTS Medium tensile steel
N/ Sqmm Newton per sq mm NMR Nominal muster roll
OMC Optimum moisture content PCC Plain cement concrete
POL Petrol oil and lubricant pt Part
PVC Polyvinyl chloride r radius
Re Rupee Rs Rupees
RCC Reinforced cement concrete q quintal
RR Random rubble RS Rolled steel joist
SDO Sub-Divisional Officer Sqm square metre
GL Ground level HP Horse power
I.e. That is IRC Indian road congress
---------------------------------------------------------------------------------------------------

RES - NIC MPSU 00 - GENERAL Page 6 of 6


Page 7 of 132
01 - JUNGLE CLEARANCE
NOTES :
1.1 Rates cover all costs of tools and plants required for clearance of jungle and falling of
trees including uprooting, stacking the cut and felled-material within a lead of 50m.
1.2 Girth of trees shall be generally measured at one meter above the ground level unless
otherwise specified.
1.3 Site and jungle clearance will ordinarily by done departmentally unless otherwise
ordered in writing by the Executive Engineer.
1.4 In case of jungle clearance, felling and uprooting of trees, it is not possible to measure
work after clearance and uprooting unless initial records of jungle and trees to be felled are
maintained. Therefore the area to be cleared and uprooted should be marked at site in
advance and recorded by the Sectional Officer and checked by the S.D.O. before the work
is commenced. Final measurements should by entered by the Sectional Officer and
checked by the S.D.O.
1.5 Shrub jungle includes trees up to 20cm. girth.
1.6 No useful wood is expected to be available from shrub jungle clearance.
1.7 The wood obtained by the Department shall be auctioned after one notice or it shall be
handed over to the Forest or Revenue Department as may be decided by S.E. (If it is not
required by the deptt.)
1.8 Where the jungle belongs to the Forest Department, it should generally be got cleared
and disposed off by the Forest Department unless otherwise ordered by the Executive
Engineer in writing for special reasons.
1.9 For survey and investigation, the item 0101 is not payable.
1.10 For items and 1706 to 1708 of chapter "Survey and Investigation" the jungle
clearance is not payable.
1.11 For item 1705 of chapter "Survey and Investigation" generally no separate payment
for jungle clearance is required, however, when the alignments are passing through jungle
and clearance is considered necessary by the Executive Engineer, the payment for jungle
clearance can be made, depending upon the type of jungle involved. Payments for Jungle
Clearance can be made for widths not exceeding 1.5m. for alignments and 1 m. for cross
sections as per items 0107 to 0109 on specific prior written sanction of the Executive
Engineer, which will include the type of jungle clearance to be done in different length
and widths as considered necessary.

Code Description Unit Rate (Rs.)

0101 Site clearance, cutting grass, raking into heaps and removing off the sqm. 3.4
premises
0102 Jungle clearance including uprooting of rank vegetation, grass, brush sqm. 8.4
wood, saplings and tree not exceeding 30cm girth and removing not
exceeding 50meters outside the periphery of the area cleared.
0103 Deduct from items 0102 for uprooting not done. sqm. 5.0

0104 Cutting down trees (exceeding 30cm girth, grubbing uproot, filling pits
and levelling off ground, lopping branches, trimming, removing not
exceeding 50meter & staking serviceable material and cleaning site.
(a) Girth exceeding 30 cm and not exceeding 100 cm Each 1460.1
(b) Girth exceeding 100 cm and not exceeding 150 cm Each 2526.4
(c) Girth exceeding 150 cm and not exceeding 200 cm Each 2917.0

RES - NIC MPSU 01 - JUNGLE CLEARANCE Page 1 of 2


Page 8 of 132

Code Description Unit Rate (Rs.)

0104 Cutting down trees (exceeding 30cm girth, grubbing uproot, filling pits
and levelling off ground, lopping branches, trimming, removing not
exceeding 50meter & staking serviceable material and cleaning site.
(d) Girth exceeding 200 cm and not exceeding 250 cm Each 3405.9
(e) Girth exceeding 250 cm and not exceeding 300 cm Each 3888.1

0105 Deduction from items 0104 (a) to 0104 (e) for uprooting not done. Each. 50% of
respective item
0106 Uprooting of roots of trees including removing and stacking (Girth to be Each. 50% of
measured at 1.00 m above G.L.) respective item
0107 Ordinary shrub jungle (areas below 25% covered by shrubs) clearance sqm. 1.2
involving removal of grass. Shrubs, bushes and twigs, excluding uprooting
(for survey works)
0108 Medium shrub jungle (25% to 50% area covered by shrubs) clearance sqm. 2.4
involving removal of grass. Shrubs, bushes and twigs, excluding uprooting
out (for survey works)
0109 Thick shrub jungle (area above 50% covered by shrubs) clearance sqm. 3.6
involving removal of grass. Shrubs, bushes and twigs, excluding uprooting
out (for survey works)

RES - NIC MPSU 01 - JUNGLE CLEARANCE Page 2 of 2


Page 9 of 132
02 - MORTARS
NOTES :
2.1 Rates includes all leads and lifts.
2.2 Sand shall confirm to IS 2166-1965 for masonry mortar and IS 1542-1960 for plaster.
2.3 Cement shall confirm to any one of the following specification. IS 1489-1976 Portland
pazzolana cement. IS 455-1976 Portland slag cement. IS 269-1976 ordinary or low heat
Portland cement.
2.4 Building lime shall confirm to IS 712-1973
2.5 Surkhi shall be made from well burnt or slightly under burnt brick bats or from
suitable clay burnt at required temperature, surkhi shall confirm to IS 1344-1968.
2.6 the strength of various proportions of lime mortar/cement mortar shall be in
accordance with IS1625-1965 and IS 2250-1965.
2.7 Hydrated lime can be used in place of lime putty.
Code Description Unit Rate (Rs.)

0201 Mud Mortar cum 437.4

0202 Lime Mortar 1:2 ( 1 lime putty, 2sand ) cum 1845.4

0203 Lime Mortar 1:3 ( 1 lime putty, 3sand ) cum 1704.8

0204 Lime Surkhi Mortar 1:1:1 ( 1 lime putty, 1 surkhi, 1sand ) cum 1742.7

0205 Lime Surkhi Mortar 1:1:2 ( 1 lime putty, 1 surkhi, 2sand ) cum 1628.0

0206 Lime Surkhi Mortar 1:2 ( 1 lime putty, 2 surkhi,) cum 1639.9

0207 Labour only for lime mortar & lime surkhi mortar cum 567.7

0208 Cement Mortar 1:2 ( 1 cement, 2 sand ) cum 3520.6

0209 Cement Mortar 1:3 ( 1 cement, 3 sand ) cum 2860.9

0210 Cement mortar 1:4 ( 1 cement, 4 sand ) cum 2318.6

0211 Cement Mortar 1:5 ( 1 cement, 5 sand ) cum 2026.6

0212 Cement Mortar 1:6 ( 1 cement, 6 sand ) cum 1776.3

0213 Cement Mortar 1:8 ( 1 cement, 8 sand ) cum 1442.6

0214 Labour only for Cement Mortar cum 292.6

0215 Cement Lime Mortar 1:1:3 ( 1 cement, 1 lime putty, 3 sand ) cum 3186.1

0216 Cement Lime Mortar 1:1:4 ( 1 cement, 1 lime putty, 4 sand ) cum 3119.6

0217 Cement Lime Mortar 1:1:5 ( 1 cement, 1 lime putty, 5 sand ) cum 2738.9

0218 Cement Lime Mortar 1:1:6 ( 1 cement, 1 lime putty, 6 sand ) cum 2432.8

0219 Cement Lime Mortar 1:1:8 ( 1 cement, 1 lime putty, 8 sand ) cum 2109.1

RES - NIC MPSU 02 - MORTARS Page 1 of 2


Page 10 of 132

Code Description Unit Rate (Rs.)

0220 Cement Lime Mortar 1:2:9 ( 1 cement, 2 lime putty, 9 sand ) cum 2195.4

0221 Cement Lime Mortar 1:3:12 ( 1 cement, 3 lime putty, 12 sand ) cum 2076.7

0222 Labour only for cement lime mortar cum 662.8

0223 White cement mortar 1:2 ( 1 White cement, 2 Marbel dust) cum 8956.1

RES - NIC MPSU 02 - MORTARS Page 2 of 2


Page 11 of 132
03 - EXCAVATION
NOTES:
3.1 MEASUREMENTS
Measurement of earth work will generally be taken by pit measurement, only when such
measurement are not practicable cross sectional measurement may be taken, however
incase of earthen bunds constructed to retain water, only cross sectional measurements will
be taken.

3.1.1 The length, breadth and depth (or height) shall be measured correct to the nearest cm.
If the measurements are taken with level and staff, the levels shall be recorded correct to 5
mm. The area shall be calculated in Sqm. correct to two places of decimal and cubical
contents in cum correct to two places of decimal.
3.2.Classification of Strata -
(a) Loose or soft soil - Generally any soil which yields to the ordinary application of pick
and shovel, or to spade, rake or other digging implement, such as vegetable or organic soil
turf, gravel, sand, silt, loam, clay, peat, etc.
(b) Hard or dense soil- includes all materials which can be removed with shovel or spade
after loosening with pick axe, such as clay, soil mixed with lime kanker, black cotton soil
for earthen bund, soft moorum etc.
(c) Hard moorum and moorum mixed with boulders. - Generally any material which
requires the close application of picks, jumpers or scarifies to loosen, such as hard and
compact moorum and soft shale. Moorum or soil mixed with small boulders not exceeding
25 % in quantity and each less than 0.014 cum (300 mm dia or 1/70 cum) but more than
0.004 cum in size. " Boulder is a rock fragment usually rounded by weathering,
disintegration or exfoliation or abrasion by water, found lying loose on the surface or
embedded in material of dissimilar origin "
(d) Disintegrated or soft rock - Disintegrated or soft rock include such strata's which
require the close application of crow bars, picks, grafting tools and scarifies in suitable
combination for its excavation such as soft laterite, soft conglomerate hard shale, soft
copra hard and compacted moorum mixed with small boulders exceeding 25 % in quantity
but each not exceeding 0.014 cum in size and soft rock comparies of the following -
(i) Boulders (dia more than 300 mm but not greater than 0.50 cum in volume) hard laterite,
hard copra and hard conglomerate or other rock which may be quarried or split with crows
bars, with casual blasting, if required, for loosening of strata.
(ii) Any rock which in dry state may be hard, requiring blasting, but when wet becomes
soft and manageable by means other than blasting.
(e) Hard rock (requiring blasting) - Any rock or boulder (more than 0.5 cum in volume)
which requires use of mechanical plant or blasting for excavation or splitting.
(f) Hard rock (Blasting prohibited) - Hard rock requiring blasting as described under (e)
but where blasting is prohibited for any reason and excavation has to be carried out by
chiselling, wedging or any other agreed method.
3.3 Authority for classification :- The classification shall be decided by the Executive
Engineer and his decision shall be final.
3.4 Dressing - (a) Dressing is normally required at one place i.e. at the place of excavation
or at the place of filling hence the rates provided in the schedule include dressing only
once, either at the place of cut or at the place of fill. In case of canal excavation, where
earth is reused at or near the same place and for the same work, in such case only one
dressing which is already included in the basic rates is admissible, even though the
dressing is actually needed at both the places i.e. at the place of cut and at the place of fill,
Page 12 of 132
while additional rate for trimming in cutting only will be payable.
(b) In case, dressing is not done either in cut or in fill or both rate for dressing will be
reduced.
(c) No separate payment for dressing or trimming of spoil bank (s) and borrow area (s)
shall, be made.
3.5 Trimming -
(a) This comprises of removing grass and grass roots, touching the uneven surface (either
horizontal or slopping), by scraping off high patches and filling in low patches with the
scraped soil. The maximum depth of cutting or not exceeding 15 cm.
(b) This item of work shall however, not be payable for road work maintenance of
approach roads, service roads, etc. as well as where payment for dressing in earth work/
excavation has already been made.
3.6 Wet excavation.- Extra rate for excavation will be payable only for excavation below
sub-soil water level Trial pits shall be dug in the area where excavation is required to be
done. The steady water level in the trial pits which is left undisturbed for 48 hours before
the pumping operations are started, shall be considered as sub-soil water level in the area.
3.7 Rates for items 0301 to 0309 include 50m. free lead and 1.5 m. free lift.
3.8 Lifts.
(a) Lift for all modes of handling has to be measured in an upward direction, i.e. when the
materials are moved against the force of gravity.
(b) Lift will be calculated on the height of the centre of gravity of the lifted material above
the average of ground levels at the Centre as well as upstream and down stream toe at
section of the dam/embankment. For working out extra lift payable, the initial 1.5 m free
lift shall be deducted.
(c) In the case of earthwork for canals in partial or full cutting, lift will be calculated on the
completed section of the work done from the centre of gravity of the cutting portion to the
centre of gravity of embankment minus 1.5 m free lift.
(d) In the case of canal excavation where spoil bank is formed in number of sections, more
than one, the quantity in each spoil bank has to be fitted into the canal excavation. The lifts
payable will be for the centre of gravity of excavated portion to the centre of gravity of the
corresponding spoil bank minus 1.5m free lift.
(e) No negative (downward) lift shall be payable for earth work /excavation.
(f) The estimate for Earthen dam embankment be sanctioned on the basis of approved
designs considering utilisation of useful available materials from excavation of approach
spill channel (s). The estimate for approach/spill channel (s) be sanctioned only for the
balance excavation which cannot be utilised. The payment shall also be made accordingly.
For the entire excavated materials of approach /spill channel (s) lift is payable from the
centre of gravity of the excavated portions to the centre of gravity of the banks and
deductions of 1.5 m free lift shall be made to work out the extra lift payable. However, for
the useful materials transported to the dam/ embankment lift would be payable, as per (c)
above.
3.9. Lead
(a) Extra lead for earthwork by head load beyond initial 50m free lead will be payable for
every additional 50m or part there of up to a total distance of 200m.
(b) The lead for earthwork shall be measured from the centre of borrow area (s) to the
centre line of the dam/ embankment and shall be measured as crow flies, the crow fly
distance being measured from the geometrical centre of borrow area (s) to the centre of the
dam/embankment. While calculating the lead for payment an additional five percent over
the distance calculated above shall be added to cover circuitous path.
(c) The extra lead charges for earthwork when total distance exceeds 200m (head load
Page 13 of 132
lead) will be payable as per chapter "TRANSPORTATION OF MATERIALS".
3.10.Bailing out water.-
(a) Rates do not include any allowance for bailing out of water.
(b) For excavation done departmentally the bailing out of water not requiring pumping,
shall be done as a separate items, as per actual expenses. The decision of the Executive
Engineer, as to whether or not pumping is necessary for bailing out water in any particular
case, shall be deemed as final.
3.11. Rates of items 0301 to 0309 include the following : -
(a) Separation of serviceable and unserviceable material and depositing them separately in
regular heaps or stacks as directed. Where stacking of material is done under specific
orders of the Executive Engineer with a view to utilise the entire materials on other items
of works, separate rate for stacking shall be payable.
(b) Forming (or leaving) 'dead men' to ' tell-tales' in borrow pits and their removal after
measurements.
(c) Removing slips or falls in excavations.
(d) Forming (or leaving) steps in sides of deep excavation and their removal after
measurements.
(e) Precautionary measures to be adopted in blasting as per IS 4081-1967 "Safety code of
blasting" (as amended from time to time) and storing explosives as per "Explosive Rules
1940" corrected uptodate.
3.12. Antiquities.- Any ancient carvings, relics of antiquity, coins or other curiosities
which may be discovered or excavated are the property of the Government and are to be
delivered to the Engineer-in-Charge.
3.13. Any vegetation, earth, moorum, sand, gravel, debris, brickwork, concrete, masonry
etc. obtained form excavation shall form the property of the Government.
3.14.Removal of earth deposits from the bed of new channels- Removal of the earth/soil
deposited, including due to slips etc. in the bed of channel could be paid as per item no
0301, only when the estimate for its removal has been prepared on the basis of cross
sections, longitudinal section plotted on graph measurement book (s), duly compared with
the Completed/ executed/designed sectioned and later sectioned by the Competent
Authority. Such work could than be executed through contract " Agency on form A or
form B "

Code Description Unit Rate (Rs.)

0301 Earth work in bulk excavation (exceeding 30cm in depth, 1.5m in width as
well as 10sqm on plan) including disposal of excavated soil lead upto 50m
and lift upto 1.5m, disposed soil to be levelled and neatly dressed.
(a) Loose or soft soil cum 103.7
(b) Dense or hard soil cum 134.1
(c) Hard moorum cum 177.8

0302 Earth work in bulk excavation (exceeding 30cm in depth, 1.5m in width as
well as 10sqm on plan) including disposal or stacking of excavated soil
lead upto 50m lift upto 1.5m
(a) Disintegrated or soft rock (not requiring blasting) cum 413.5
(b) Hard rock requiring blasting cum 497.8
(c) Hard rock requiring chiselling (where blasting is prohibited) cum 881.9

0303 Deleted ---- ----

RES - NIC MPSU 03 - EXCAVATION Page 3 of 5


Page 14 of 132

Code Description Unit Rate (Rs.)

0304 Earth work in rough excavation, filling excavated earth into depressions
on banking as directed, top surface to be levelled and neatly dressed.
(a) Loose or soft soil cum 115.2
(b) Dense or hard soil cum 148.1
(c) Hard moorum cum 166.4

0305 Deleted ---- ----

0306 Deleted ---- ----

0307 Earth work in excavation in trenches for foundations and for pipes, cables
etc. not exceeding 1.5m in width and for shafts, cesspits and the like not
exceeding 10sqm on plan including dressing of sides and ramming of
bottoms lift upto 1.5m including getting out the excavated soil and
disposal of surplus excavated soil as directed, within a lead of 50m
(a) Loose or soft soil cum 111.7
(b) Dense or hard soil cum 145.8
(c) Hard moorum cum 191.2

0308 Excavation in trenches for foundations and for pipes, cables, etc. not
exceeding 1.5m in width and for shafts, cesspits and the like not exceeding
10 sqm on plan including dressing of sides and ramming of bottoms, lift
upto 1.5m including getting out and stacking the excavated soil and
disposal of surplus excavated soil as directed within a lead of 50m
(a) Disintegrated or soft rock (not requiring blasting) cum 457.7
(b) Hard rock requiring blasting cum 615.2
(c) Hard rock requiring chiselling (i.e. hard rock requiring blasting but cum 909.5
where blasting is prohibited)
0309 Extra rates for quantities of work executed. In or under water or in foul cum 20% of
condition (extra rate for the main item concerned is allowed on account of respective item
slow progress of works)
0310 Excavating post holes (or similar holes) upto 0.5cum including getting out
the excavated soil, than returning the soil as required in layers not
exceeding 20cm in depth, including consolidating each deposited layer by
ramming, watering etc., disposing of surplus excavated soil as directed
within a lead of 50m and making good the surface.
(a) Loose or soft soil nos. 104.7
(b) Dense or hard soil nos. 135.5
(c) Disintegrated or soft rock (not requiring blasting) nos. 273.5

0311 Boring holes 3.5m deep in ordinary soil (for cast in situ piles) and getting
out the soil (under ramming if any shall be paid for separately) and
disposal of the surplus excavated soil as directed within a lead of 50m
for-Diameter of piles.
(a) 200 mm nos. 612.8
(b) 250 mm nos. 733.4
(c) 300 mm nos. 857.3

0312 Extra for under-ramming inside the bore holes for under reamed piles.

(a) 200mm nos. 232.8

RES - NIC MPSU 03 - EXCAVATION Page 4 of 5


Page 15 of 132

Code Description Unit Rate (Rs.)

0312 Extra for under-ramming inside the bore holes for under reamed piles.

(b) 250mm nos. 291.8


(c) 300mm nos. 347.7

0313 Add to or deduct from the rate for bore holes of 3.5metre depths, if the
bore-holes are made deeper or shallower than 3.5metres.
(a) 200mm RM 195.6
(b) 250mm RM 260.8
(c) 300mm RM 291.8

0314 Deleted ---- ----

0315 Deleted. ---- ----

0316 Surface dressing of ground, including removing vegetation, and/ or


unequalities not exceeding 15cm deep and disposal of rubbish lead upto
50m And lift upto1.5m
(a) Loose or soft soil sqm. 8.2
(b) Dense or hard soil sqm. 11.5

0317 Dag-beling

(a) Single spade stroke minimum 75mm deep RM 0.5


(b) ....

0318 Extra for every additional Lead beyond 50metres or part thereof upto 200 cum 45.2
m for every 50 m lead
0319 Pumping out water caused by springs tidal or river seepage, broken water kl. 70.4
mains or drains or well point pumping and the like.
0320 Deduct from item no.0301, 0303, 0304, 0307 & 0308 If dressing either cum 10 % extra of
not done or not done as per specification respective item
0321 Dry silt clearance in drainage and culvert etc. cum 74.0

0322 Extra for every additional lift of 1.5 m or part there of

(a) Loose/soft soil and dense/hard soil cum 12.2


(b) Disintegrated/ soft or hard rock cum 21.3

0323 Construction of embankment/sub grade by fly ash including clearing & cum 74.0
grabbing existing surface, (as per clause 305 and its sub clauses where
required and as per IRC SP-58-2001) i/c all lifts, cost of spreading,
watering, compaction and maintenance of surface during construction to
ensure shedding and preventing ponding of water, providing camber,
shaping and dressing, finishing etc. complete. (lead for fly ash will be paid
extra excluding loading)

RES - NIC MPSU 03 - EXCAVATION Page 5 of 5


Page 16 of 132
04 - FILLING FOUNDATION, CONCRETE WORK
NOTES :
4.1 Rates include :-
(a) All leads and lifts of matrerials unless otherwise specified.
(b) The cost of materials in which water includes.
(c) The cost of mixing motor, curing and scaffolding etc

4.2 Rates do not include centring, shuttering or form work unless otherwise specified.

4.3 Rates are also applicable for filling under floors.

4.4 Form work of RCC will be provided by the contractor and shall be removed by him.
No lead and lift of form work will be payable.

4.5 For RCC work the rates includes all finishing on all exposed surface, projections etc. as
per design. The resulting surface should be smooth and plain. Bottom faces of RCC slabs,
lintels and chajjas etc. shall be finished with suitable thickness of 1:3 cement mortar to
make surface smooth and even, where ever required. Ceiling plaster shall not be paid
separately in any case.

4.6 The rate includes for centring for providing fan hooks etc. For drip course where ever
required the seperate rates will be paid.

4.7 For plum concrete the plum used shall be of 150 mm maximum size rubble.

4.8 For fine and coarse aggregates IS 383 - 1970 may be referred, for plain and reinforced
concrete IS 456 - 2000 may be referred.

4.9 No seperate payment for lead and lift shall be permissible unless otherwise specified.
4.10 The proportion of various size of coarse aggregates in concrete is detailed below.
(This quantities are for 1 cum of concrete)
………………………………………………………………………………………
Concrete Max size of Metal or single Size and qty Total
Mix. Graded metal in cum.
………………………………….
40 mm 20 mm 10 mm
………………………………………………………………………………………
C.C. 1:2:4 20 mm - 0.67 cum 0.22 cum. 0.89cum

C.C. 1:3:6 40 mm 0.65 cum 0.24 cum - 0.89cum

C.C. 1:3:6 20 mm - 0.70 cum 0.24 cum 0.94cum

C.C. 1:4:8 40 mm 0.65 cum 0.24 cum - 0.89cum


C.C. 1:5:10 40 mm 0.65 cum 0.24 cum - 0.89cum
C.C. 1:6:12 40 mm 0.65 cum 0.24 cum - 0.89cum
Lime concrete 40 mm 0.69 cum 0.50 cum - 0.94cum
with lime mortar
any ratio.
Page 17 of 132

4.11 Items of R.C.C. includes formworks, centering, shuttering, proping, finishing and
curing etc.

4.12 Rates of centering and shuttering should be paid only for the item in which rates
excluding cost of formwork is mentioned.
4.13 Execution of R.C.C. work shall not be permitted without mixer and vibrator.
Code Description Unit Rate (Rs.)

0401 Filling available excavated earth (excluding rock) in trenches, plinth, sides cum 74.0
of foundation etc. in layers not exceeding 20cm in depth consolidating
each deposited layers by ramming and watering lead upto 50m and lift
upto 1.5m
0402 Filling foundation, around masonry work, plinth, sides of foundation etc. cum 257.1
with moorum I/c ramming layers not exceeding 20cm in depth
consolidating each deposited layers by ramming and watering lead upto
50m and lift upto 1.5m.
0403 Labour only for item no.0402 cum 74.0

0404 Filling in plinth with sand under floors including watering, ramming, cum 284.3
consolidating and dressing complete.
0405 Labour only for item no. 0404 cum 61.5

0406 Deleted …. ....

0407 Deleted …. ....

0408 Providing and laying in foundation, plinth and under floors lime concrete
with 40mm nominal size graded stone aggregates (metal) and 40% lime
mortar. i/c ramming in layers and curing complete excluding cost of form
work.
(a) Lime mortar 1:2 (1lime putty, 2sand) cum 2006.8
(b) Lime mortar 1:3 (1lime putty, 3sand) cum 1942.5
(c) Lime mortar 1:1:1 (1lime putty, 1surkhi, 1sand) cum 1959.8
(d) Lime mortar 1:2 (1lime putty, 2surkhi) cum 1912.8

0409 Labour only for item no. 0408 (for any proportion of lime mortar used) cum 938.7

0410 Deduct from item No. 0408 if shingles (pebbles) are used in place of cum 302.9
40mm nominal metal.
0411 Providing and laying on terrace upto floor two level lime concrete with cum 1735.8
graded brick aggregate 25mm nominal size and 50% mortar comprising of
1 lime putty and 2 surkhi and curing etc. complete.
0412 Labour only for item no. 0411. cum 850.4

0413 Providing and laying in foundation, plinth and under floors cement
concrete with 40mm nominal size graded stone aggregates (metal) i/c
ramming in layers and curing complete excluding cost of form work
(a) C.C. 1:2:4 (1cement, 2sand, 4metal) cum 2895.3
(b) C.C. 1:3:6 (1cement, 3sand, 6metal) cum 2401.8
(c) C.C. 1:4:8 (1cement, 4sand, 8metal) cum 2062.6
(d) C.C. 1:5:10 (1 cement, 5sand, 10metal) cum 1877.2

RES - NIC MPSU 04 - FILLING FOUNDATION, CONCRETE WORK Page 2 of 4


Page 18 of 132

Code Description Unit Rate (Rs.)

0413 Providing and laying in foundation, plinth and under floors cement
concrete with 40mm nominal size graded stone aggregates (metal) i/c
ramming in layers and curing complete excluding cost of form work
(e) C.C. 1:6:12 (1 cement, 6sand, 12metal) cum 1784.5
(f) C.C 1:2.5:5 ( 1cement, 2.5 sand, 5metal) cum 2665.9

0414 Labour only for item no. 0413 (for any proportion of cement concrete) cum 732.3

0415 Add to item No. 0413 for concrete work in super structure upto floor two cum 15 % of item
level for wall independent pillars and like. no. 0414 for
each floor
0416 Add to item No. 0413 and 0415 if in place of 40mm metal.

(a) If 20 mm graded metal is used cum 59.5


(b) If 12 mm graded metal is used cum 74.4

0417 Extra rate for providing and fixing in position upto floor two level, units cum 1937.6
of precast C.C. work of any mix fixing in cement mortar 1:2 and finishing
with cement plaster 6mm thick in cement mortar 1:3 including scaffolding
.
0418 Extra rate for laying cement concrete in or under water or liquid mud cum 103.6
including cost of pumping and bailing out and removing slush etc.
complete.
0419 Extra rate for providing and mixing water proofing material in cement Bag 39.3
concrete work in the proportions recommended by the manufacturers.
0420 Providing and laying damp proof course 50mm thick with C.C.1:2:4 with sqm. 220.4
20mm size graded stone aggregate. including curing.
0421 Applying one coat of hot bitumen (80/100) or equivalent using 1.7kg. Per sqm. 71.1
sqm On damp proof courses after cleaning the surface with brushes and
finally with a piece of cloth tightly soaked in kerosene oil.
0422 Plum cement concrete 1:2:4 with 75% graded metal of 40mm size and cum 2055.3
25% plums of 150mm size.
0423 Plum cement concrete 1:3:6 with 75% graded metal of 40mm size and cum 1866.6
25% plums of 150mm size.
0424 Plum cement concrete 1:4:8 with 75% graded metal of 40mm size and cum 1711.5
25% plums of 150mm size.
0425 Providing and placing in position RCC for roof, beams, columns column
footing lintels chhajjas, balcony, stairs etc, excluding cost of
reinforcement but including centring, shuttering, proping, finishing &
curing etc.complete.
(a) CC 1:1:2 (1 cement, 1 sand, 2 graded stone aggregate 20mm cum 5274.3
nominal size)
(b) CC 1:1.5:3 (1 cement, 1.5 sand, 3 graded stone aggregate 20mm cum 4593.4
nominal size)
(c) CC 1:2:4 (1 cement, 2 sand, 4 graded stone aggregate 20mm cum 4253.0
nominal size)
0426 Labour only for item 0425. cum 1023.1

0427 Add extra for labour only for additional floor or 6.m height and part cum 15 % of item
thereof PCC or RCC work in item no.0426 no. 0426 for
each floor
0428 Deleted …. ....

RES - NIC MPSU 04 - FILLING FOUNDATION, CONCRETE WORK Page 3 of 4


Page 19 of 132

Code Description Unit Rate (Rs.)

0429 Deleted …. ....

0430 Deleted …. ....

0431 Labour only for item no. 0430 sqm. 98.9

0432 Deleted …. ....

0433 Deleted …. ....

0434 Providing and laying five courses damp proofing treatment sumps, sqm. 441.8
reservoirs, roof etc. consisting of 1st. 3rd and 5th courses of blown type
petroleum bitumen of I. S. grade 85/25 applied @1.6kg/sqm and 2nd and
4th courses of self finished bitumen felt type 3 grade 2 (Hessian Base)
with priming coat of bituminous solution applied hot at the rate of
minimum of 0.25litre per sqm including preparation of surface by grouting
cracks, providing cement concrete fellets rounding of cerlers etc. wherever
required and cleaning and drying of surface before priming cost is applied,
complete as per direction of the engineers-in-charge.
0435 Providing and filling in position blown bitumen in expansion joints (10cm RM 7.9
deep and 1cm Wide)
0436 Deduct from item no 0413 if 63mm graded metal used in place of 40mm cum 37.2
metal
0437 False work for Arches up to 6meter span. sqm. 973.9

0438 Labour only for item no. 0437 sqm. 522.2

0439 Brick bat filling in trenches or soak pits. cum 325.6

0440 Labour only for item no.0439 cum 125.4

RES - NIC MPSU 04 - FILLING FOUNDATION, CONCRETE WORK Page 4 of 4


Page 20 of 132
05 - STONE MASONRY
NOTES :
5.1 Rates include :-
(a) All leads and lifts of matrerials unless otherwise specified.
(b) The cost of materials in which water includes.
(c) The cost of mixing motor, curing and scaffolding etc.
5.2 Plum Stones (Pin Headers) - Pin headers or plum stones shall be provided in hearting
at 1.8m interval (both across and along) the shall run through the height of at least two
courses. Their position shall be staggered in successive courses.
5.3 Joints - The maximum thickness of joints shall be 20mm for hammer dressed coursed
rubble masonry and random rubble uncoursed masonry.
5.4 Masonry for massive structures and Masonry dams - Having maximum height 15m and
above (height means structural height above lowest foundation level an is applicable to
entire length of dams) and other massive structure -
(a) Face masonry - Face stones shall be hammer dressed on face and one line chisel
dressed (finishing given to the stone face with no portion of it projecting more than 10
mm from the straight edge laid along the face of the stone) on bed, top and sides for 75
mm from the face batter. The bushing on the faces of the stones shall not project more then
4 cm.
(b) Coursed Rubble Masonry - Stone shall be hammer dressed on face, side and bed 75
mm with the course normal to the face batter, the bushing on the faces of the stones shall
not project more the 4 cm.
(c) Random Rubble Masonry - the hearting is of random rubble work.
5.5 The bushing on the face shall not project by more then 10 mm on face to be plastered.
5.6 Rates for masonry in foundation and plinth, in case of building works and other
works, which can be done without scaffolding, are applicable to all works upto plinth
level.
5.7 For compound wall the masonry from foundation bed upto 1.5 m above surrounding
ground level (average) shall be treated as masonry in foundation and plinth and extra
height then shall be treated as masonry in super structure.
5.8 Concrete headers and corners shall be used if proper stone headers and corners are not
available. Concrete headers shall be precast at site in 1:3:6 C.C. with 20 mm metal and
shall be cured. No extra payment should be made.
5.9 The stone will be laid in horizontal course in not less then 15 cm height
5.10 No seperate payment for lead and lift shall be permissible unless otherwise specified.
5.11 Following Indian standard may be referred to,
IS No.. Title
1597(part-1)-1967 Code of practice for construction of stone masonry rubble stone
masonry.
1394 - 1979 Specification for stone lintels.
Code Description Unit Rate (Rs.)

0501 Labour only for dressing stones hammer or rough dressed for C. R. cum 477.9
masonry work second sort.
0502 Random/ uncoursed rubble masonry in plinth and foundation, stones laid cum 1163.6
dry, well bounded, faced with selected stones and built with through
stones evenly placed at the rate of two per sqm
0503 Labour only for item no.0502 cum 566.2

RES - NIC MPSU 05 - STONE MASONRY Page 1 of 3


Page 21 of 132

Code Description Unit Rate (Rs.)

0504 Random / uncoursed rubble masonry in plinth and foundation with mud cum 1497.6
mortar including levelling at plinth level.
0505 Labour only for item no 0504 cum 868.9

0506 Random / uncoursed rubble masonry in plinth and foundation including


levelling up with cement concrete 1:6:12 (1cement, 6coarse sand, 12
aggregate 20mm nominal size) at plinth level.
(a) In Lime mortar 1:2 (1lime putty, 2sand) cum 2248.9
(b) In Lime mortar 1:3 (1lime putty, 3sand) cum 2195.8
(c) In Cement mortar 1:4 (1cement, 4sand) cum 2539.4
(d) In Cement mortar 1:5 (1cement, 5sand) cum 2429.2
(e) In Cement mortar 1:6 (1cement, 6sand) cum 2334.7
(f) In Cement mortar 1:8 (1cement, 8sand) cum 2208.6

0507 Labour only for random/ uncoursed rubble masonry in any. Mortar for cum 953.5
item no.0506 excluding labour for preparation of mortar.
0508 Coursed rubble masonry second sort in plinth and foundation.

(a) In Lime mortar 1:2 (1lime putty, 2sand) cum 2551.1


(b) In Lime mortar 1:3 (1lime putty, 3sand) cum 2502.9
(c) In Cement mortar 1:3 (1cement, 3sand) cum 3001.4
(d) In Cement mortar 1:4 (1cement, 4sand) cum 2815.2
(e) In Cement mortar 1:5 (1cement, 5sand) cum 2715.0
(f) In Cement mortar 1:6 (1cement, 6sand) cum 2629.1
(g) In Cement mortar 1:8 (1cement, 8sand) cum 2514.5

0509 Labour only for C.R. masonry in mortar of any ratio as in item no.0508 cum 1384.4

0510 Stone shelves fixed in walls in cement mortar 1:3 (1cement, 3sand) I/c
finishing complete.
(a) 30 mm thick sqm. 277.9
(b) 40 mm thick sqm. 287.7
(c) 50 mm thick sqm. 327.3

0511 Labour only for item no.0510 sqm. 136.7

0512 Providing and fixing in cement mortar 1:6 (1cement, 6sand) flag stone
slab over drains.
(a) 30 mm thick sqm. 246.5
(b) 40 mm thick sqm. 256.3
(c) 50 mm thick sqm. 295.9

0513 Labour only for item no.0512 sqm. 100.0

0514 Providing and fixing chhajja (sun shed) of stone 40mm thick and upto sqm. 433.3
80cm wide beyond the wall in cement mortar 1:4 I/c pointing in cement
mortar 1:2.
0515 Labour only for item no. 0514 sqm. 246.2

RES - NIC MPSU 05 - STONE MASONRY Page 2 of 3


Page 22 of 132

Code Description Unit Rate (Rs.)

0516 Extra rate for C.R./ R.R./ U.C.R. stone masonry in super structure above cum 292.8
plinth level upto floor two level.
0517 Extra rate for laying stone work in or under water and or liquid mud cum 103.6
including cost of pumping or bailing out water and removing slush etc,
complete etc.(For every 0.3 meter depth)
0518 Providing and fixing fine dressed cut stone lintels of any size including cum 8415.2
setting in C.M. 1:2.
0519 Labour only for item no.0518 cum 4002.4

0520 Extra over item for additional lift for C.R. stone masonry work in super cum 1% rate of
structure above floor two level. stone masonary.

RES - NIC MPSU 05 - STONE MASONRY Page 3 of 3


Page 23 of 132
06 - BRICK MASONRY
NOTES :
6.1 The rates include -
(a) All leads and lifts of all matrerials unless otherwise specified.
(b) The cost of mixing all types of motor.
(c) The cost of all materials including water.
(d) The cost of curing and scaffolding etc.
6.2 Work in Foundation and plinth :- For purpose of measurements of masonry work in
foundations and plinths it shall be determined as follows-
(a) For Building- Masonry work below plinth level or 1.2m above average ground level,
which ever is lower.
(b)For abutments, piers and retaining walls of culverts, bridges, walls of reservoirs, septic
tanks, basement and other similar works upto 1.5 m above top of foundation concrete.
6.3 Classification of Brick Masonry :-
(a) The common burnt clay brick shall be classified on the basis of minimum average
compressive strength.
(b) Various types of bricks when tested in accordance with IS 3495(part 1)-1976 shall have
minimum average compressive strength as follows -
(i) Class 50 chimney kiln burnt brick/Grog or Ghoul bricks………….50kg/sq cm.
(ii) Class 35 chimney kiln burnt bricks.……………………………...35kg/sq cm.
(iii) Class 25 open bhatta or pajawa burnt brick………………...…..25kg/sq cm.
(iiii) Kumhar brick Class 20 burnt in pajawa………………………...20kg/sq cm.
6.4 Normally modular bricks shall be used for building however the traditional bricks can
be used with the permission of E.E. (where the modular bricks are not readily available)
6.5 Measurements :-
(i) The brick walls upto 3 bricks in thickness shall be measured in multiples of half brick,
which shall be deemed to be inclusive of mortar viz.
………………………………………………………………………………………
Brick wall In case of In case of
modular bricks traditional
bricks bricks
………………………………………………………………………………………
(a) 1\ 2 Brick wall 10 cm 11 cm
(b) 1 Brick wall 20 cm 23 cm
(c) 1.5 Brick wall 30 cm 34 cm
(d) 2 Brick wall 40 cm 46 cm
………………………………………………………………………………………
and so on irrespective of excess of executed width.
(ii) For walling which is more then three bricks in thickness actual thickness of wall shall
be measured.
(iii) The full area of honey comb brick masonry shall be measured without deductions for
openings.
(iv) No deduction or additions shall be made on account of the following-
(a) Ends of dissimilar materials (Joists, beam lintels, posts, girders, rafters, purlins, trusses,
corbels, steps and like) upto 0.1 Sqm in section.
(b) Wall plates, bed plates and bearing of slabs, chhajjas and the like where thickness does
not exceed 10 cm and bearing does not extend over the full thickness of wall.
(c) C.C. blocks for hold fasts and holding down bolts.
(d) Iron fixtures, such as wall ties, pipes upto 300 mm dia. and hold fasts for doors and
Page 24 of 132
windows.
6.6 Before use, all brick shall be soaked in clean water in tank or pit for at least two hours.
Brick shall be laid with frog upwards and set with both bed and vertical joints filled with
mortar and imbedded in by tapping with handle of the trowel. The thickness of joints will
in no case exceed 10mm, hold fasts shall be fixed in C.C. 1:3:6 to be paid separately no
broken, crushed, or under burnt bricks shall be used. The joints in faces are to be plastered
or pointed shall be raked out while mortar is green i.e. not later then 24 hours.
6.7 No seperate payment for lead and lift shall be permissible unless otherwise specified.
6.8 The following Indian Standard may be referred to -
IS Code Title
1077-1976 Specification for common burnt clay building bricks (third revision)
2212-1962 Code of practice for brick work .
3102-1971 Classification of burnt clay solid bricks (First revision)
1905-1957 Code of practice for structural safety of building, masonry, walls (First
revision) 3495-1976 Methods of tests of burnt clay building bricks (second
revision)
5454-1978 Methods of sampling of clay building bricks (first revision)

Code Description Unit Rate (Rs.)

0601 Sun dried brick masonry in plinth and foundation in clay mortar. cum 1105.4

0602 Labour only for item no.0601 cum 706.9

0603 Class 25 open bhatta or pajawa burnt brick masonry in plinth and cum 2512.1
foundation in clay mortar.
0604 Labour only for item no.0603 cum 706.9

0605 Class 25 open bhatta or pajawa burnt brick masonry in plinth and
foundation.
(a) Lime Mortar 1: 2(1lime, 2sand) cum 2938.7
(b) Lime mortar 1:3 (1lime putty, 3sand) cum 2904.9
(c) Lime surkhi mortar 1:1:1 (1lime, 1surkhi, 1sand) cum 2914.0
(d) Lime surkhi mortar 1:1:2 (1lime, 1surkhi, 2sand) cum 2886.5
(e) Cement lime mortar 1:1:6 (1cement, 1lime, 6sand) cum 3080.7
(f) Cement lime mortar 1:2:9 (1cement, 2lime, 9sand) cum 3023.6
(g) Cement mortar 1:3 (1cement, 3sand) cum 3253.9
(h) Cement mortar 1:4 (1cement, 4sand) cum 3123.6
(i) Cement mortar 1:5 (1cement, 5sand) cum 3053.4
(j) Cement mortar 1:6 (1cement, 6sand) cum 2993.3
(k) Cement mortar 1:8 (1cement, 8sand) cum 2913.1

0606 Add for masonry in supper structure above plinth level up to floor two cum 245.8
level
0607 Add extra for brick masonry in square or rectangular pillars. cum 261.4

0608 Add extra for brick masonry in circular pillars. cum 1055.4

0609 Add extra for brick masonry circular in plan, I/c wells to a mean radius not cum 357.8
exceeding 6m (Such as well stening and other similar type of works)

RES - NIC MPSU 06 - BRICK MASONRY Page 2 of 3


Page 25 of 132

Code Description Unit Rate (Rs.)

0610 Add for class 35 T.M. chimney kiln burnt brick in item no.0603 and 0605 cum 297.5

0611 Deduct for kumbhar brick class 20 burnt pajawa in item no. 0603 and cum 119.0
0605
0612 Labour only for brick masonry in plinth and foundation I/c making mortar cum 830.7
for item no.0605
0613 Labour only for brick masonry I/c scaffolding and making mortar in super cum 1087.9
structure for item no.0605
0614 Half brick masonry in class 25 open bhatta or pajawa burnt brick in super
structure including placing of 6mm iron bar at every 3rd layer of brick.
(a) In cement mortar 1:3 sqm. 432.9
(b) In cement mortar 1:4 sqm. 417.3

0615 Deduct for kumbhar brick class 20 burnt pajawa for item no. 0614 sqm. 12.6

0616 Add to item no.0614 for class 35 T.M. chimney burnt/ ghola bricks. sqm. 31.5

0617 Labour only for item no.0614 sqm. 130.5

0618 Honey comb brick masonry with class 25 open bhatta or pajawa burnt
brick 10cm Thick.
(a) In cement mortar 1:3 sqm. 246.1
(b) In cement mortar 1:4 sqm. 228.9

0619 Deduct for kumbhar brick class 20 burnt pajawa for item no. 0618 sqm. 8.2

0620 Add to item no.0618 for class 35 T.M. chimney burnt/ ghola bricks. sqm. 20.6

0621 Labour only for item no. 0618. sqm. 78.5

0622 Class 25 open bhatta or pajawa burnt brick masonry in plain arches in cum 3620.6
superstructure span not exceeding 6 metres in cement mortar 1:3 (1
cement, 3 coarse and) excluding centring (height of prons not exceeding
3.5 metres) and shuttering complete.
0623 Labour only for arch masonry upto 6m span excluding centring but cum 1280.2
including labour for making mortar and curing.
0624 Add to item no.0605 and 0609 for well staining

(a) For every 3meter up to 15 meter depth. cum 276.6


(b) For every 3meter beyond 15meter up to 24 meter depth. cum 406.6
(c) For every 3meter beyond 24 meter depth. cum 553.1

0625 Deleted ---- ----

0626 Add for Fly Ash brick in item no.0603 and 0605 cum -129.4

RES - NIC MPSU 06 - BRICK MASONRY Page 3 of 3


Page 26 of 132
07 - WOOD WORK AND JOINERY
NOTES:
7.1 Rates include cost of all materials for all items except items of labour only. No seperate
payment for leads and lifts shall be permissible unless otherwise specified.
7.2. Rates are for completed works fixed in position and with exposed faces finished with
bead or quick as ordered. The rates include cost of all spikes, screw, glue etc. required for
putting the work together and fixing the same.
7.3. Shutters shall be paid for the net measurement of clear opening between the frame
pieces, measurement being taken at the unrebated part of the frame. The rates are exclusive
of chowkhats.
7.4. For finished size 1.5mm tolerance will be allowed for each plain finished surface of
wood work.
7.5. Schedule of fitting to doors and windows is appended to this schedule. All fittings will
be provided accordingly.
7.6. The hold fasts, L-drops and tower bolts etc. shall be paid separately and its cost is not
include in the rates of wood work.
7.7. For shutters, the thickness of planks and braces will be as follows -
………………………………………………………………………………………
S. NO. Type of shutters Thickness
Plank Braces
………………………………………………………………………………………
1. Battened 20 mm 20 mm 25 mm
2. Battened 25 mm 25 mm 25 mm
3. Battened 30 mm 30 mm 30 mm
4. Battened 35 mm 35 mm 35 mm
5. Battened 40 mm 40 mm 40 mm

Thickness of panels

6. Panelled 25 mm 20 mm
7. Panelled 30 mm 25 mm
8. Panelled 35 mm 30 mm
9. Panelled 40 mm 30 mm
………………………………………………………………………………………

7.8. The guard bars for windows and ventilators shall be threaded at both the end and fixed
with nuts and suitable washers of MS plate of size 5cm x 5cm x 6mm thick.
7.9. The thickness of glass-pans should be 3mm or 7.5kg/Sqm unless otherwise stated for
wooden windows and ventilators.
7.10. In case of flush shutters 1.60mm tolerance will be allowed for finished sizes.
7.11. All joinery work should have bamboo nails and use of Fevicol etc. to have effective
joints necessary.
7.12. No chowkhat or shutter shall be painted before due inspection and approval by
Engineer-in-Charge.
7.13. Unless otherwise stated the gauge etc. of AC/ GI/ XPM Fly proof mesh shall be as
follows-
Plain AC sheet 5 mm thick
Plain GI sheet 22 gauge
XPM No. 19 3mm gauge x 20mm
Page 27 of 132
Fly proof mesh 22 gauge wire with 144 mesh/ sq. Inch.
7.14. Diameter of ballies should be measured at centre of ballies.
7.15. All portions of timbers like battens purlins, wall plates, door chowkhats etc. built into
or abutting the masonry or concrete should be given thick coat of hot Tar creosote or other
approved wood preservative.
7.16. All fixtures and fastenings shall be new sound and strong. They shall be sectional and
of the best quality. The size shape design and finish shall as per the sample approved by
the Executive Engineer. Number and size shall be as per standard specifications.
7.17. The following Indian Standards may be referred to -
IS CODE Title
204 Tower bolts
204 (Pt.i)1978 Ferrous metals (fourth revision)
204 (Pt.ii)1978 Non ferrous metals (fourth revision) (with amendment No.1)
205-1978 Non ferrous metal butt hinges (third revision)
206-1973 Tee and strap hinges (second revision)
207-1964 Gate and shutter hooks and eyes (revised) (reaffirmed 1977)
208-1979 Door handles (third revision)
281-1973 Mild steel sliding door bolts for use with padlock (second revision)
287-1973 Recommendation for maximum permissible moisture content for Timber
used for different purposes (second revision) (with amendment No.1)
303-1975 Plywood for general purposes (second revision) (with amendments no. 1
to 3)
362-1975 Parliament hinges (third revision)
363-1976 Hasps and staples (third revision)
364-1970 Fanlight catch (second revision)
401-1967 Code of practice for preservation of timber (second revision) ( with
amendment No.1)
419-1967 Putty, for use of windows frames (first revision)(with amendment
No.1)(reaffirmed 976)
451-1972 Technical supply conditions for wood screws (second revision)
452-1973 Door springs, rat-tail type (second revision)
453-1973 Double acting spring, hinges (second revision)
723-1972 Steel counter sunk head wire nails (second revision) (with amendments
No.1 to 3)
729-1979 Drawer locks, cupboard locks and box locks (third revision)
848-1974 Synthetic revise adhesive for plywood (phenolic and amino plastic) (first
revision)
1003 Timber panelled and glazed shutters.
1003(Pt.i)1977 Door shutter (second revision)
1003(Pt.ii)1966 Windows and ventilators shutters (first revision) (with amendments 1 to3)
1019-1974 Rim latches (second revision) (with amendment No.1)
1141-1973 Code of practice for seasoning of timber (first revision)
1328-1970 Veneered decorative plywood (first revision)
1341-1976 Steel butt hinges (third revision)
1378-1979 Oxidised copper finishes (second revision)
1658-1977 Fibre hard boards (second revision)
1659-1979 Block boards (second revision)
1868-1968 Anodic coatings on aluminium (first revision) (with amendment No.1)
2191Wooden flush door shutters (cellular and hollow core type)
2191(Pt.i)1980 Plywood face panels (third revision)
Page 28 of 132
2191(Pt.ii)1980 Particle board and hardboard face panels (second revision)
2202 Wooden flush door shutters (solid core type)
2202(Pt.i)1980 Plywood face panels (third revision)
2202(Pt.ii)1980 Particle board and hardboard face panels (second revision)
2209-1976 Mortise locks (Vertical type) (third revision) (with amendment No.1)
2380 Pt( i to xxi)1977 Methods of test for wood particle boards and boards from other
lignocellulosic materials (first revision) (with amendment No.1)
2681-1979 Non-ferrous metal sliding door bolts (Aldrops for the use
withpadlocks)(second revision)
2835-1975 Flat transparent sheet glass (second revision) (with amendment No.1)
3087-1965 Wood particle boards (medium density) for general purposes (with
amendmentNo.1).
3548-1966 Code of practice for glazing buildings
3564-1975 Door closers (hydraulically regulated) (second revision) (with amendment
No.1)
3618-1966 Phosphate treatment of iron and steel for protection against corrosion.
3813-1967 ' C' hooks for use with swivels.
3818-1971 Continuous (Piano) hinges (first revision) (with amendment No.1)
(reaffirmed 1978)
3847-1966 Mortise right latches (with amendments 1&2) (reaffirmed 1978)
4020-1967 Methods of tests for wooden flush doors. Type tests (with amendments
No.1 & 2)
4021-1976 Timber door, windows and ventilator frames (first revision).
4043-1969 Recommendations for symbolic designation of direction of closing and
faces of doors, windows and shutters.
4827-1968 Electroplated coatings of nickel and chromium on copper and copper
alloys (with amendments No.1&2)
4913-1968 Code of practice for selection installation and maintenance of timber
doors and windows.
4962-1968 Wooden side sliding doors.
4992-1975 Door handles for mortise locks (Vertical type) (first revision)
5187-1972 Flush bolts (first revision) (with amendment No.1) (reaffirmed 1978)
5437-1969 Wired and figured glass (reaffirmed 1976)
5930-1970 Mortise latch (vertical type) (with amendment No.1) (reaffirmed 1978)
6318-1971 Plastic windows stays and fasteners.
6607-1972 Rebated mortise locks (vertical type) (with amendment No.1)
(reaffirmed1978)
7196-1974 Hold fasts (with amendment No1)
7197-1974 Double action floor & springs (without oil check) for heavy doors.
8760-1978 Mortise sliding door locks with lever mechanism (with amendment No.1)
9460-1980 Flush drop handle for drawers.
Code Description Unit Rate (Rs.)

0701 Providing wood work in frames of doors, widows, clerestory widows and
other similar works brought framed and fixed in position.
(a) Bija wood cum 31879.2
(b) Sal wood cum 29117.5
(c) Other structural wood (seasond & chemicaly treated wood) cum 18070.4

RES - NIC MPSU 07 - WOOD WORK AND JOINERY Page 3 of 8


Page 29 of 132

Code Description Unit Rate (Rs.)

0702 Labour only for items no.0701. cum 1499.9

0703 For architrave moulding, railings for stairs, cornices and moulded beading cum 50% extra of
etc. For any shape pattern or dealings add to item no.0702. respective item
0704 Providing wood work in trusses, purlins, rafters, posts, post plates, wall
plates and the like brought framed, hoisted and fixed in position.
(a) Bija wood cum 69107.4
(b) Sal wood cum 66366.4
(c) Other structural wood (seasond & chemicaly treated wood) cum 55402.4

0705 Labour only for item no.0704 cum 38956.4

0706 Providing wood work in frames of false ceiling, partitions, portions etc.
sawn and put-up in position.
(a) Bija wood cum 35352.8
(b) Sal wood cum 32521.4
(c) Other structural wood (seasond & chemicaly treated wood) cum 21196.0

0707 Labour only for item no.0706 cum 4207.9

0708 Extra for additional labour for curved works, such as in frames of curved cum 10 % extra of
fan lights. respective item
0709 Providing and fixing 30mm thick double leaf panelled, glazed or panelled
and glazed shutters for doors, windows and clerestory window including
black enamelled M.S. butt hinges with necessary screws.(half glazed and
half panelled)
(a) Second class Indian teak wood sqm. 2445.2
(b) Bija wood sqm. 1423.9
(c) Sal wood sqm. 1349.5
(d) Other structural wood (seasond & chemicaly treated wood) sqm. 1052.1

0710 Providing and fixing 25mm thick double leaf panelled, glazed or panelled
and glazed shutter for cupboards etc. including black enamelled M.S. butt
hinges with necessary screws.(half glazed and half panelled)
(a) Second class Indian teak wood sqm. 2179.8
(b) Bija wood sqm. 1276.6
(c) Sal wood sqm. 1213.0
(d) Other structural wood (seasond & chemicaly treated wood) sqm. 958.4

0711 Deduct from item no. 0709 for fully panelled.

(a) Second class Indian teak wood sqm. 103.1


(b) Bija wood sqm. 88.0
(c) Sal wood sqm. 86.6
(d) Other structural wood (seasond & chemicaly treated wood) sqm. 81.1

0712 Deduct from item no. 0710 for fully panelled shutters.

(a) Second class Indian teak wood sqm. 12.5

RES - NIC MPSU 07 - WOOD WORK AND JOINERY Page 4 of 8


Page 30 of 132

Code Description Unit Rate (Rs.)

0712 Deduct from item no. 0710 for fully panelled shutters.

(b) Bija wood sqm. 42.7


(c) Sal wood sqm. 45.5
(d) Other structural wood (seasond & chemicaly treated wood) sqm. 56.4

0713 Add to item no. 0709 & 0710 if 5mm thick glass is used. sqm. 7.3

0714 Providing and fixing 25mm thick single leaf battened and framed door
shutter including bright finished or/and black enamelled M.S. butt hinges
with necessary screws.
(a) Bija wood sqm. 1126.4
(b) Sal wood sqm. 1068.5
(c) Other structural wood (seasond & chemicaly treated wood) sqm. 836.9

0715 Providing and fixing 30mm thick single leaf battened and framed door
shutter including bright finished or/and black enamelled M.S. butt hinges
with necessary screws.
(a) Bija wood sqm. 1253.8
(b) Sal wood sqm. 1184.3
(c) Other structural wood (seasond & chemicaly treated wood) sqm. 906.4

0716 Providing and fixing 35mm thick single leaf battened and framed door
shutter including bright finished or/and black enamelled M.S. butt hinges
with necessary screws.
(a) Bija wood sqm. 1381.2
(b) Sal wood sqm. 1300.1
(c) Other structural wood (seasond & chemicaly treated wood) sqm. 975.9

0717 Providing and fixing 20mm thick single leaf battened door and window
shutters with necessary ledges and braces (25mm) including bright
finished or/and black enamelled M.S. butt hinges with necessary screws.
(a) Bija wood sqm. 1513.2
(b) Sal wood sqm. 1421.3
(c) Other structural wood (seasond & chemicaly treated wood) sqm. 1053.8

0718 Providing and fixing 25mm thick single leaf battened door and window
shutters with necessary ledges and braces (30mm) including bright
finished or/and black enamelled M.S. butt hinges with necessary screws.
(a) Bija wood sqm. 1754.8
(b) Sal wood sqm. 1641.0
(c) Other structural wood (seasond & chemicaly treated wood) sqm. 1185.6

0719 Providing and fixing 30mm thick single leaf battened door and window
shutters with necessary ledges and braces (35mm) including bright
finished or/and black enamelled M.S. butt hinges with necessary screws.
(a) Bija wood sqm. 1994.9
(b) Sal wood sqm. 1859.2
(c) Other structural wood (seasond & chemicaly treated wood) sqm. 1316.6

RES - NIC MPSU 07 - WOOD WORK AND JOINERY Page 5 of 8


Page 31 of 132

Code Description Unit Rate (Rs.)

0720 Providing and fixing flush door shutters, solid core construction,
decorative type with skins of decorative veneered particle boards and
block board core, with frame of first class hard wood with particle board
veneered particle board face panels including black enamelled M.S. butt
hinges with necessary screws.
(a) 40 mm thick (double leaf) sqm. 1791.1
(b) 30 mm thick (double leaf) sqm. 1565.2
(c) 25 mm thick (double leaf) sqm. 1371.4

0721 Providing and fixing flush door shutters, solid core construction,
Non-decorative type (paintable) with skins of particle boards unveneered
and block board core, with frame of first class hard wood with particle
board veneered particle board face panels including black enamelled M.S.
butt hinges with necessary screws.
(a) 40 mm thick (double leaf) sqm. 1346.3
(b) 30 mm thick (double leaf) sqm. 967.0
(c) 25 mm thick (double leaf) sqm. 904.8

0722 Providing and fixing flush door shutters, solid core construction,
Non-decorative type (paintable) with skins of particle boards veneered
with commercial veneers and block board core, with frame of first class
hard wood with particle board veneered particle board face panels
including black enamelled M.S. butt hinges with necessary screws.
(a) 40 mm thick (double leaf) sqm. 1303.6
(b) 30 mm thick (double leaf) sqm. 1149.2
(c) 25 mm thick (double leaf) sqm. 1096.7

0723 Providing and fixing flush door shutters, hollow core construction,
decorative type with skins of decorative veneered particle boards with
frame of first class hard wood, with particle board or veneered particle
board face panels including black enamelled M.S. butt hinges with
necessary screws.
(a) 40 mm thick (double leaf) sqm. 1478.0
(b) 30 mm thick (double leaf) sqm. 1347.2
(c) 25 mm thick (double leaf) sqm. 1252.8

0724 Providing and fixing flush door shutters, hollow core construction,
Non-decorative type (paintable) with skins of particle boards, unveneered
with frame of first class hard wood, with particle board or veneered
particle board face panels including black enamelled M.S. butt hinges with
necessary screws.
(a) 40 mm thick (double leaf) sqm. 1242.6
(b) 30 mm thick (double leaf) sqm. 1111.7
(c) 25 mm thick (double leaf) sqm. 947.5

0725 Providing and fixing flush door shutters, hollow core construction,
Non-decorative type (paintable) with skins of particle boards veneered
with commercial veneers, with frame of first class hard wood, with
particle board or veneered particle board face panels including black
enamelled M.S. butt hinges with necessary screws.
(a) 40 mm thick (double leaf) sqm. 1129.2
(b) 30 mm thick (double leaf) sqm. 911.1

RES - NIC MPSU 07 - WOOD WORK AND JOINERY Page 6 of 8


Page 32 of 132

Code Description Unit Rate (Rs.)

0725 Providing and fixing flush door shutters, hollow core construction,
Non-decorative type (paintable) with skins of particle boards veneered
with commercial veneers, with frame of first class hard wood, with
particle board or veneered particle board face panels including black
enamelled M.S. butt hinges with necessary screws.
(c) 25 mm thick (double leaf) sqm. 773.1

0726 Extra for using bright finished M.S. piano hinges instead of anodised
aluminium butt hinges in flush door shutters.
(a) Nickel plated M.S piano hinges sqm. 183.4
(b) Brass plated M.S piano hinges sqm. 102.6

0727 Deduct Iron butt hinges with necessary screws are supplied by the sqm. 28.0
department free of cost for flush door shutter.
0728 Add extra for double leaf shutter cum 10 % extra of
respective item
0729 Providing and fixing 30mm thick wire gauze shutters using galvanised
wire gauze of I.S. gauze designation 85G with wire of dia. 0.56mm for
doors, windows and clerestory window including bright finished or/ and
black enamelled M.S. butt hinges with necessary screws.
(a) Bija wood sqm. 920.5
(b) Sal wood sqm. 865.6
(c) Other structural wood (seasond & chemicaly treated wood) sqm. 646.0

0730 Providing and fixing plain trellis work of 40X12mm Laths placed 40mm
apart (frames to be paid separately) including fixing 50X12mm beading
complete with
(a) Bija wood sqm. 885.9
(b) Sal wood sqm. 840.6
(c) Other structural wood (seasond & chemicaly treated wood) sqm. 659.3

0731 Labour only for item no.0730 sqm. 387.4

0732 Providing and fixing plain trellis work of half rounded (split) bamboos sqm. 559.0
40mm dia. placed at 40mm apart (frames to be paid separately) including
fixing 40mm dia. beading of half round bamboos.
0733 Labour only for item no.0732 sqm. 246.9

0734 Providing and fixing expanded metal 20x60mm strands 3.25mm wide and sqm. 409.3
1.6mm thick for windows etc. including 60X20mm beading of sal wood.
0735 Providing and fixing fly proof galvanised M.S. wire gauze of I.S. gauze sqm. 308.4
designation 85G with wire of dia. 0.56mm to windows and clerestory
window including 60X20mm beading of sal wood.
0736 Providing and fixing hard brown steel wire fabric 75x25mm mesh of sqm. 494.1
weight not less then 7.75kg. per sqm to window frames etc. including
60X20mm beading of sal wood.
0737 Providing and fixing Sal ballies in posts purlins, rafters, post plats etc.
including cost of iron nails and spikes required and applying wood
preservative on all unexposed surface.
(a) 80 mm diameter RM 33.8
(b) 100 mm diameter RM 51.2
(c) 125 mm diameter RM 59.7

RES - NIC MPSU 07 - WOOD WORK AND JOINERY Page 7 of 8


Page 33 of 132

Code Description Unit Rate (Rs.)

0737 Providing and fixing Sal ballies in posts purlins, rafters, post plats etc.
including cost of iron nails and spikes required and applying wood
preservative on all unexposed surface.
(d) 150 mm diameter RM 69.2

0738 Labour only for item no.0737

(a) 80 mm diameter RM 11.1


(b) 100 mm diameter RM 16.6
(c) 125mm diameter RM 22.2
(d) 150 mm diameter RM 27.7

RES - NIC MPSU 07 - WOOD WORK AND JOINERY Page 8 of 8


Page 34 of 132
08 - CEILING AND WALL BOARDING
NOTES :
8.1 No seperate payment for lead and lift shall be permissible unless otherwise specified.
8.2 Rates for ceiling are also applicable to soffits, sun shades and eave boards.
8.3 The rates include
(a) Cutting the material to required size, shape and pattern.
(b) Fixing with GI or brass screws, nails or panel pins etc. as ordered
(c) Painting to battens.
8.4 All work shall be measured net without allowance for wastage.
8.5 The wooden battens fixed in the ceiling for beads shall be of finished size 45mm X
12mm and shall be planned, moulded, beaded and spaced as directed by Engineer-in
charge. The beading should be fixed to the frame with 5cm screw and spacing not
exceeding 30cm or as directed by the Engineer-in-charge, over lap of beading shall be
mitred at junction.
8.6 For cloth ceiling the battens shall from square or long panels not more than 1.5m in
length of any side. For ceiling of plain AC sheets, or hard board sheet, the spacing of
battens shall not exceed 60cm. The battens shall be so arranged as to provide panels of
uniform size and shape as for as possible.

Code Description Unit Rate (Rs.)

0801 Providing and fixing plain Asbestos cement sheet ceiling with butt jointing sqm. 258.9
and wood screws (frame work and cover fillets to be measured and paid
separately) B class 5mm Thick A.C. sheet.
0802 Labour only for item No. 0801. sqm. 58.0

0803 Providing and fixing hessian cloth ceiling with nails (frame work and sqm. 67.1
cover fillets to be measured and paid separately)
0804 Labour only for item no. 0803. sqm. 38.3

0805 Providing and fixing fiber hard board sheet, lining with but jointing and
nails (frame work and cover fillets to be measured and paid separately) .
(a) Deleted ....
(b) Normal hard boards 5 mm thick sqm. 94.1
(c) Normal hard boards 6 mm thick sqm. 103.5

0806 Labour only for item no. 0805 sqm. 36.3

0807 Providing and fixing 12mm thick decorated type veneered particle board sqm. 265.3
lining with but jointing and nails (frame work and cover fillets to be
measured and paid separately) .
0808 Labour only for item no. 0807 sqm. 35.2

0809 Providing 10mm thick plaster of Paris (Gypsum anthydrous) ceiling up to sqm. 788.0
a height of 5 metres above floor level over Bija wood strips 25 X 6mm
with 10mm gap in between and rein forced with rabbit wire mesh fixed to
wooden frame(frame work and cover fillets to be measured and paid
separately) .
0810 Labour only for item no. 0809 sqm. 312.6

RES - NIC MPSU 08 - CEILING AND WALL BOARDING Page 1 of 1


Page 35 of 132
09 - IRON WORK
NOTES:
9.1 No seperate payment for lead and lift shall be permissible unless otherwise specified.
9.2 The rates include -
(a) All forging, drilling, topping, punching etc. and every description of workmanship
necessary to fabricate, finish, erect and fix in position all steel and iron work in a good
manner.
(b) All bolt and nuts including holding down and anchor plates, rivets, packing pieces,
gusset plates, cleats, wedges etc. (weight for these articles being taken in the main articles)
(c) Spikes, nails and screw required (Weight not to be included in the main articles)
(d) Notching, finishing etc.
(e) All necessary templates, patterns, moulds etc.
9.3 The measurements should be of the finished fabricated section no wastage to be
accounted for.
9.4 (a) Mild steel reinforcement shall confirm to IS : 226-1975, IS : 432 (part I)-1982, IS :
1139-1966 as applicable, and shall be of tested quality, For steel, the contractor must
produce a test certificate of the manufactures. In case of doubt independent tests shall be
carried out according to IS : 1608-1972, IS : 1599-1974 and IS : 226-1975 and the cost of
such tests shall be born by the contractor.
(b) Cold bend test shall be performed in presence of the Sub-Divisional Officer-In-charge
for all size of steel reinforcement used and a certificate recorded in measurement book by
the Sub-Divisional Officer at site.
9.5 Binding wire of 18 SWG, should be used for RCC work.
9.6 The standard hooks, overlaps and spacer bars shall be measured. The rate includes all
handling of bars, straightening, removal of harmful scales, coal tar, bitumen or lime etc.
from the surface properly.
9.7 Cross bars and spacer bars must be secured tightly with 18 SWG wire.
9.8 The guard bars windows and ventilators shall be threaded at both the ends and fixed
with suitable nuts and washers of MS plate of size 5cm x 5cm x 6mm thick.
9.9 The glass panes for fixing to windows shall not weight less than 7.5kg per Sqm.
9.10 The glass pans to steel work shall be fixed with glazing clips and putty confirming to
IS.
9.11 For the building works based on percentage rate or item rate contracts :-
(a) The steel used in reinforcement and other structural steel shall be measured as the
actual quantity of steel placed in the finished structure. The hooks, overlaps and spacer
bars, both end riveted shall be measured.
(b) When steel is supplied by the department, it shall be paid for the labour charges for
steel on the quantity measured vide note (a) above.
(c) Mild steel round bars or deformed bars (left over after use in work) more than 3 metre
in length will be accepted in return. If the quantity issued after the deduction is more than
quantity measured plus 3% it will be a charged at issue rate plus 10 % or the market rate
whichever is more for the difference. If the actual wastage is below 3 % of the steel used
recovery for wastage as per actual shall be made. (d) If the steel is arranged by the
contractor full rate shall be payable for the steel actually placed in finished structure.
9.12. Angle iron for fencing includes 15cm cutting, bending, shaping and fix in position.
9.13. The following Indian Standards may be referred to -
IS Code title
226-1975 Structural steel (standard quality) (fifth revision) (with amendment
No.1to3)
Page 36 of 132
278-1978 Galvanised steel barbed wire for fencing (third revision)
280-1978 Mild steel barbed wire for fencing (third revision)
412-1975 Expanded metal steel sheets for general purpose (with amendment no.1)
432-1966 Mild steel and medium tensile steel bars (second revision)(with
amendment no.1to3)
800-1962 Code of practice for use of structural steel in general building construction
(revised) (with amendment no.1 & 2)
806-1967 Code of practice for use of steel tubes in general building deconstruction
(first revision) (with amendment no.1)
816-1969 Code of practice for use of metal arc welding for general construction in
mild steel (first revision)construction in mild steel (first revision)construction in mild steel
(first revision)(with amendment no.1 & 2)
818-1968 Code of practice for safety and health requirements in electric and gas
welding and cutting operations (first revision)
822-1970 Code of practice for inspection of welds.
823-1964 Code of practice for manual metal arc welding of mild steel (with
amendment no.1)
1038-1975 steel doors, windows and ventilators (second revision)
1081-1961 Code of practice for fixing and glazing (steel and aluminium)doors,
windows, and ventilators (with amendment no.1)
1161-1979 Steel tubes for structural purposes (third revision)
1361-1978 Steel windows for industrial buildings (third revision)
1521-1972 Method of tensile testing of mild steel wire (first revision)
1566-1967 Hard drawn steel wire fabric for concrete reinforcement (first revision) (with
amendment no.1)
1599-1974 Methods of bend test for steel products other than sheet, strip, wire and tube
(first revision) (with amendment no.1)(reaffirmed 1980)
1608-1972 Method of tensile testing of steel tubes (first revision)
1786-1979 Cold worked steel high strength deformed bars for concrete .
1894-1972 Method of tensile testing of steel tubes (first revision)
1948-1968 Aluminium doors, windows and ventilators (with amendments no.1)
1949-1961 Aluminium windows for industrial buildings (with amendments no.1)
1977-1975 Structural steel (fusion welding quality)(second revision)(with amendment
no.1 to 3)
2062-1980 Structural steel (fusion welding quality) (second revision)
2140-1978 Standard Galvanised steel wire for fencing (first revision)
2502-1963 Code of practice for bending and fixing or bar for concrete reinforcement.
2721-1979 Galvanised steel chain link fence fabric (first revision)
4351-1976 Steel door frames (first revision) (with amendment no.1)
4948-1974 Welded steel wire fabric for general use (first revision) (with amendment
no.1)
4996-1968 Reinforcement concrete fence posts.
5049-1969 Gauge for wire diameters (with amendment no.1)(reaffirmed 1977)
5067-1969 Fencing pliers (reaffirmed 1978)
6227-1971 Code of practice for use of metal arc welding in tubular structures.
6248-1979 Metal rolling shutters and rolling grills.
7152-1974 Strong room doors (with amendment no.1)
8629-1977 Code of practice for protection of iron and steel structures from
atmospheric corrosion.
9077-1979 Code of practice for corrosion protection of steel reinforcement in R.B.and
Page 37 of 132
R.C.C. construction.
9.14 Use of untested steel is not permitted.

Code Description Unit Rate (Rs.)

0901 Steel work in single section including in cutting, hoisting fixing in position kg. 43.1
in R.S. joists, channels, angles, tee.
0902 Steel work welded in built up sections, framed work, including cutting kg. 66.9
hoisting fixing in position in gratings, frames, guard bars, ladders, railing,
brackets and similar works & trusses and trussed purlins up to 25m span
and 15 m over all height
0903 Steel work in built up tubular trusses including cutting, hoisting, fixing in kg. 58.9
position, welded and bolted including special shaped washers etc.
complete of Mild steel tubes, electric resistant or induction butt welded
0904 Providing and placing in position tested steel for R.C.C. work including
cutting, bending, binding etc. as per drawings and placing in position
complete up to floor two level including cost of binding wire and all
wastage etc. complete.
(a) Mild steel and Medium tensile steel bars kg. 51.0
(b) Cold twisted / Hot rolled deformed / Thermo mechanicaly treated kg. 52.3
steel bars
0905 Deleted ---- ----

0906 Labour only for item no.0904 kg. 7.3

0907 Providing hard drown steel for R.C.C. work upto floor two level. kg. 44.2

0908 Labour only for item no.0907 kg. 1.2

0909 Providing and fixing in position collapsible steel shutters with vertical sqm. 4092.4
channels 20mm x 10mm x 2mm braced with flat iron diagonals 20mm x
5mm size with top and bottom rails of T-iron 40mm x40mm x6mm with
38mm dia steel pulleys complete with bolts and nuts, locking
arrangements, stoppers, handles.
0910 Labour only for item no.0909 for fixing only sqm. 149.6

0911 Providing and fixing rolling shutters of approved make, made of 80mm
wide M.S. Leith interlocked together through their entire length and
jointed together at the ends by end locks mounted on specially designed
pipe shaft, with brackets plates guide channels and locking with push pull
operation complete including the cost of hood over and spring.
(a) 80 x 1.25mm M.S. laths with 1.25mm thick top cover sqm. 1133.6
(b) 80 x 1.20mm M.S. laths with 1.20mm thick top cover sqm. 995.2
(c) 80 x 0.90mm M.S. laths with 0.90mm thick top cover sqm. 939.3

0912 Labour only for item no.0911 for fixing only sqm. 154.3

0913 Providing and fixing 27.5cm long wire spring grade No.2 approved make nos. 222.9
for rolling shutters.
0914 Providing and fixing hood cover for rolling shutters.

(a) 1.25mm thick RM 218.3


(b) 1.20mm thick RM 200.1
(c) 0.90mm thick RM 163.8

RES - NIC MPSU 09 - IRON WORK Page 3 of 6


Page 38 of 132

Code Description Unit Rate (Rs.)

0915 Providing and fixing ball bearings of approved make for rolling shutters RM 204.7
exceeding 8.00 sqm area.
0916 Fixing standard steel doors, windows and ventilators in walls with 16 x sqm. 154.3
3.15mm to 10cm long embedded in cement concrete block 15 x 10cm
x10cm size, of 1:3:6 (1cement, 3coarse sand, 6stone aggregate 20mm
nominal size) or with wooden plugs and screws or rawl plugs & screws or
with fixing clips or worth bolts and nuts as required, (only steel doors/
windows/ ventilators shall be supplied for fixing free of cost at site of
work or cost of supply of one or more of these material (s) shall be paid
under separate items (s)
0917 Providing and fixing steel glazed doors, windows and ventilator of
standard Rolled steel sections without horizontal glazing bars, joints
mitred and welded with 16X3.15mm lugs 10cm long, embedded in cement
concrete block 1:3:6 cement concrete with 20mm graded metal of nominal
size or with wooden plugs and screws or rawl plugs and screws or with
fixing clips or with bolts and nuts including providing and fixing of
projecting hinges, handles, peg-stys, bolting devise, locking arrangements,
spring catch etc. as required complete and Providing and fixing of 5mm
thick glass panes with steel glazing clips special metal sash putty of
approved make I/c applying a priming coat of steel primer red oxide zinc
chromite etc. complete.
(a) Steel doors, windows side hung & ventilator top/ central hung. sqm. 1272.4
(b) Steel doors, windows & ventilator fixed sqm. 916.6

0918 Providing and fixing pressed steel door frames manufactured from
commercial mild steel sheet of 1.25mm thickness including hinges jamb,
lock jamb, bead and if required angle threshold of mild steel angle of
section 50 X 25mm, or base ties of 1.25mm pressed mild steel welded or
rigidly fixed together by mechanical means, adjustable lugs with split end
tail to each jamb including steel butt hinges 2.5mm thick with mortar
guards, lock strike- plate and shock absorbers as specified as directed by
Engineer-in -charge.
(a) Profile A (single rabate 80mm X 50mm size) RM 221.7
(b) Profile B (single rabate 100mm X 50mm size) RM 249.3
(c) Profile C (double rabate 115mm X 50mm size) RM 263.1

0919 Providing and fixing in position door shutters made up of cold rolled
framed profiles of pressed steel made from commercial M.S. sheet I/c
buzzers(shock absorbers) lock, 30cm Long strike plate and necessary
tower bolts, aldrop 300x16mm Etc. complete, painted with red oxide
primer paint manufactured by standard make.
(a) Single panel shutter type-A (Made of 1.00mm C.R. sheet) sqm. 949.9
(b) Single panel shutter type-B (Made of 0.8mm C.R. sheet) sqm. 863.5
(c) Double panel shutter type-A (Made of 1.00mm C.R. sheet) sqm. 1165.7
(d) Double panel shutter type-B (Made of 0.8mm C.R. sheet) sqm. 1079.4

0920 Providing and fixing M.S. round or square bars at required spacing in kg. 60.1
wooden frames of windows and clear-story windows including standard
threads at the ends of M.S. round window bars I/c cost of standard
hexagonal nuts and washers at both ends.
0921 Providing and fixing M.S. round or square bars with M.S. flats at required kg. 54.2
spacing in wooden frames of windows and clerestory windows.

RES - NIC MPSU 09 - IRON WORK Page 4 of 6


Page 39 of 132

Code Description Unit Rate (Rs.)

0922 Providing and fixing M.S. grills of required pattern to wooden frames of kg. 89.6
windows etc. with M.S. flats at required spacing and frame around, round
or square bars with round headed bolts and nuts or by screws.
0923 Providing and fixing M.S. round holding down or anchor bolts with nuts kg. 45.7
and washer plates complete.
0924 Providing and fixing M.S. fan clamp type I of 16mm dia. M.S. bar bent to Each 95.0
shape with hooked ends in RCC slabs during laying including painting the
exposed portion of loops all as per standard design complete.
0925 Providing and fixing turn buckets and straining bolts for barbed wire Each 106.6
fencing.
0926 Providing and fixing fencing consisting 5 horizontal and 2 diagonals rows RM 257.2
of G.I Barbed Wire(minimum weight 9.38 Kg/100mt. As per IS 278:1962
Type 1), M.S. angle iron post 50x50x6mm (confirming to I.S. 225) 1.50
metre height above ground level and 0.30 m below ground level, c/c
spacing of each post shall not exceed 2.25 m with diagonal strut to hold
the fencing in line & level. Angle of size 50x50x6mm, length 1.00 m at
every fourth post fixed with nuts, bolts I/c applying a priming coat of steel
primer & painting with black paint to posts & struts etc. complete
including securing and screwing with G.I. tying wire, G.I. Staples, G.I.
U-Nails or steel pins etc. complete with cost of excavation & filling
cement concrete M-15 grade for fixing posts & struts to the pit of size
0.30x0.30x0.30 M for each post and struts etc. complete.
0927 Deduct in item No. 0926 if

(a) Angle iron 40x40x5mm size posts used RM 53.7


(b) Wooden ballies of size 125mm dia used RM 127.5

0928 Labour only for streching of barbed wire RM 2.1

0929 Labour only for fixing of R.C.C. posts, Angle iron posts or wooden ballies Each 63.5
of any size I/c excavation of pit 30x30x30cm And cost of concrete 1:3:6
with 40mm metal excluding cost of posts.
0930 Providing and fixing barbed wire fencing with 5 rows of horizontal barbed RM 199.0
wire and 2 digonal rows tightened to RCC post as per IS:4996-1984, 2M
long, 1.4 m above and 0.6 m belowe ground level, c/c spacing of each post
shall not exceed 3M with diagonal strut at every 30M to hold the fencing
in line and level. Top and bottom section of RCC post shall be 100mm X
100mm and 150mm X 150mm respectively, with iron pins casted in post.
The weight of two ply GI barbed wire shall not be less than 9.38 kg per
100 m lenght of wire. The RCC post shall be casted in M-20 cement
concrete as per IS:456-2000, with reinforcement as per IS:432-1982,
10mm dia 4 nos longitudinal bars and 6mm dia stirrups @ 150mm c/c,
complete with cost of excavation & filling cement concrete M-15 grade
for fixing posts & struts to the pit of size 0.30x0.30x0.60 M for each post
and struts etc. complete.

RES - NIC MPSU 09 - IRON WORK Page 5 of 6


Page 40 of 132

Code Description Unit Rate (Rs.)

0931 Providing and fixing barbed wire fencing with 5 rows of horizontal barbed RM 154.6
wire and 2 digonal rows tightened to RCC post as per IS:4996-1984,
1.85M long, 1.25 m above and 0.6 m belowe ground level, c/c spacing of
each post shall not exceed 3M with diagonal strut at every 30M to hold the
fencing in line and level. Top and bottom section of RCC post shall be
85mm X 85mm and 125mm X 125mm respectively, with iron pins casted
in post. The weight of two ply GI barbed wire shall not be less than 9.38
kg per 100 m lenght of wire. The RCC post shall be casted in M-20
cement concrete as per IS:456-2000, with reinforcement as per
IS:432-1982, 6mm dia 4 nos longitudinal bars and 3.15mm dia stirrups @
100mm c/c, complete with cost of excavation & filling cement concrete
M-15 grade for fixing posts & struts to the pit of size 0.30x0.30x0.60 M
for each post and struts etc. complete.
0932 Providing & fixing of stop dam Kari shutters each of 40 to 60 cm height kg. 57.0
and width as per size of opening of stop dam, according to specific
requirement of engineer in charge (for height & width of shutter). Kari
shutters shall be fabricated with 3mm thick MS sheet on frame of MS
angle 35x35x5mm size with two diagonal stiffeners of MS angle
35x35x5mm. For shutter having width more than 1.00m, one extra
horizontal stiffener of MS angle size 35x35x5mm shall be provided at
center, including priming coat on shutter complete. The rate of shutter
includes filling the space between Kari shutter by B.C. soil with watering
and ramming.

RES - NIC MPSU 09 - IRON WORK Page 6 of 6


Page 41 of 132
10 - PLASTERING AND POINTING
NOTES :
10.1 The rates include -
(a) All leads and lifts of matrerials unless otherwise specified.
(b) The cost of materials in which water includes.
(c) The cost of mixing motor, curing and scaffolding etc
10.2 Rates are inclusive of raking of joints, preparation of surfaces, erection and removal
of scaffolding, finishing, curing and cleaning.
10.3 Measurements : -
(a) Dimensions shall be measured correct to the nearest cm. The area shall be calculated in
Sqm correct to two places of decimal.
(b) Measurement of wall plastering shall be taken between walls or partitions (dimensions
before plastering being taken) for length and form top of the floor or skirting to ceiling for
height. Depth of cornices or cover, if any, shall be deducted.
(c) Deductions - For jams, soffits sills etc. for openings not exceeding 0.5Sqm. each in
area, for ends of joists, beams, posts, girders, steps etc. not exceeding 0.5Sqm. in area and
for openings exceeding 3sqm. each, deduction and additions shall be made in the following
manner -
(i) No deduction shall be made for ends of joists, beams, posts, etc. and openings not
exceeding 0.5 Sqm. each and no addition shall be made for reveals, jambs, sofftis sills etc.
of these opening nor for finish (finish to plaster) around ends of joists, beams, posts etc.
(ii) Deductions for openings exceeding 0.5Sqm but not exceeding 3Sqm each shall be
made as follows and no additions shall be made for reveals, jambs, soffits sills etc of these
openings.
(iii) When both faces of wall plastered/ pointed with same type of plaster/ pointing,
deduction shall be made for one face only.
(iv) When two faces of wall are plastered/ pointed with different types plaster/ pointing or
if one face is plastered and the other pointed deduction shall be made from the plaster or
pointing on the side on which the width of reveal is less then that on the other side, but no
deductions shall be made from plaster or pointing on the other side. Where widths are
equal, deductions of 50% of area of opening on each face shall be made from areas of
plastering and / or pointing as the case may be.
(v) When only one face is plastered and the other face is not plastered, full deduction shall
be made from plaster if width of reveal on plastered side is less then that on unplastered
side, but if width of reveal on both sides are equal or width of reveal on plastered side is
more, no deduction shall be made nor any addition shall be made for reveals, jambs,
soffits, sills etc.
(vi) When width of door frame is equal to thickness of wall or is projecting beyond
thickness of walls, full deduction for opening shall be made from each plastered face of the
wall
10.4 Plastering and pointing in C.M.1:3 shall be done with prior written permission of the
Superintending Engineer.
10.5 Thickness of plaster shall be exclusive of the thickness of key that is grooves or open
joints in brick or stone work or space between laths. The minimum thickness over any
portion of the surface shall not be less then specified thickness by more then 3mm.
10.6 Only 10 or 15mm thick plaster will be allowed for all thickness of brick walls except
on one side of 20 cm or one brick wall except on where 20mm thick plaster, if actually
done will be paid. Plaster more then 15mm thick on brick work except on one side of
20cm thick brick wall shall be done with prior written permission of the superintending
Page 42 of 132
Engineer.
10.7 No seperate payment for lead and lift shall be permissible unless otherwise specified.
10.8 The following Indian Standards may be referred to -
IS No. Title
1661-1972 Code of practice for application of Cement and Cement - Lime plaster
finishes
2212-1962 Code of practice for brick work (with amendment no.1)
2394-1965 Code of practice for application of lime plaster finish.
2402-1963 Code of practice for external rendered finishes.
2750-1964 Steel scaffoldings (with amendment no.1 to 3)
Code Description Unit Rate (Rs.)

1001 Mud plaster

(a) 15 mm thick mud plaster in two coats. sqm. 46.7


(b) 20 mm thick mud plaster in two coats. sqm. 41.9

1002 Labour only for item no.1001(a)and(b) sqm. 33.0

1003 15mm thick lime plaster in

(a) Lime surkhi mortar 1:1:1 (1lime, 1surkhi, 1sand) sqm. 117.6
(b) Lime surkhi mortar1:1:2 (1 lime, 1surkhi, 2 sand) sqm. 115.4
(c) Lime surkhi mortar 1:2 (1lilme, 2surkhi) sqm. 115.7
(d) Lime mortar 1:2 (1 lime, 2 sand) sqm. 119.6

1004 Labour only for 15mm thick lime surkhi and lime plaster of any ratio. sqm. 83.9

1005 10mm thick cement plaster on fair side of wall in

(a) Cement mortar 1:3 (1cement, 3sand) sqm. 111.6


(b) Cement mortar 1:4 (1cement, 4sand) sqm. 104.5
(c) Cement mortar 1:5 (1cement, 5sand) sqm. 100.7
(d) Cement mortar 1:6 (1cement, 6sand) sqm. 97.5

1006 Labour only for 10mm thick cement plaster of any ratio. sqm. 68.1

1007 15mm thick cement plaster on rough side of wall in

(a) Cement mortar 1:3 (1cement, 3sand) sqm. 145.9


(b) Cement mortar 1:4 (1cement, 4sand) sqm. 135.2
(c) Cement mortar 1:5 (1cement, 5sand) sqm. 129.5
(d) Cement mortar 1:6 (1cement, 6sand) sqm. 124.6

1008 Labour only for 15mm thick cement plaster of any ratio. sqm. 85.9

1009 Deleted ....

1010 Deleted ....

1011 6mm cement plaster to Ceiling.

(a) In Cement mortar 1:3 (1cement, 3sand) sqm. 123.9

RES - NIC MPSU 10 - PLASTERING AND POINTING Page 2 of 6


Page 43 of 132

Code Description Unit Rate (Rs.)

1011 6mm cement plaster to Ceiling.

(b) In Cement mortar 1:4 (1cement, 4sand) sqm. 119.4

1012 Labour only for item no.1011 sqm. 94.5

1013 Rough cast plaster using ordinary cement with a mixture of sand and sqm. 247.3
gravel or crushed stone graded from 2.36mm to 12.5mm nominal size
dashed over and including the fresh plaster in two layers. Under layer
12mm plaster 1:5 (1cement, 5sand) and top layer 10mm cement plaster
(1cement, 3sand)mixed with 10% fine grounded Hydrated lime by volume
of cement.
1014 Labour only for item no.1013 sqm. 174.2

1015 Extra rate for finishing with a floating cot of neat cement slurry over sqm. 36.8
cement plaster of any thickness.
1016 Extra rate for providing and mixing water proofing cement material in kg. 39.3
cement mortar for cement plaster in proportions recommended by
manufactures.
1017 Extra over items for plastering of circular walls not exceeding 6m in sqm. 13.3
radius
1018 Extra over plastering on ceiling and soffits of stairs upto floor two level sqm. 23.8
instead of plastering on wall.
1019 15mm thick water proofing mud plaster in tar coal, backing coat with sqm. 85.8
12mm thick mud mortar consisting of 70kg of chopped straw and 60kg of
bitumen coat with 3mm thick gobri leaping mixed with 100kg of bitumen
cut back per cum of soil on brick/stone masonry walls for interior
plastering upto floor two level I/c arisen, interval rounded angle not
exceeding 80mm in girth and finished even to smooth.
1020 Pointing on brick work with lime mortar 1:2 (1lime putty, 2sand)

(a) Flush pointing sqm. 112.9


(b) Ruled pointing sqm. 116.6

1021 Pointing on brick work with cement mortar 1:3 (1cement, 3sand)

(a) Flush pointing sqm. 119.7


(b) Ruled pointing sqm. 121.1
(c) Raised and cut pointing sqm. 179.7

1022 Pointing on brick work with cement mortar 1:4 (1cement, 4sand)

(a) Flush pointing sqm. 115.6


(b) Ruled pointing sqm. 119.2
(c) Raised and cut pointing sqm. 176.8

1023 Labour only for item no.1020 to 1022

(a) Flush pointing sqm. 98.5


(b) Ruled pointing sqm. 101.8
(c) Raised and cut pointing sqm. 156.3

1024 Pointing on flat brick flooring with cement mortar 1:3 (1cement, 3sand)

RES - NIC MPSU 10 - PLASTERING AND POINTING Page 3 of 6


Page 44 of 132

Code Description Unit Rate (Rs.)

(a) Flush pointing sqm. 90.6


(b) Ruled pointing sqm. 94.6

1025 Pointing on flat brick flooring with cement mortar 1:4 (1cement, 4sand)

(a) Flush pointing sqm. 89.3


(b) Ruled pointing sqm. 93.3

1026 Labour only for item no.1024 and 1025

(a) Flush pointing sqm. 84.5


(b) Ruled pointing sqm. 88.5

1027 Pointing on brick on edge flooring with cement mortar 1:2 (1cement,
2sand)
(a) Flush pointing sqm. 109.8
(b) Ruled pointing sqm. 113.2

1028 Pointing on brick on edge flooring with cement mortar 1:3 (1cement,
3sand)
(a) Flush pointing sqm. 107.6
(b) Ruled pointing sqm. 110.9

1029 Pointing on brick on edge flooring with cement mortar 1:4 (1cement,
4sand)
(a) Flush pointing sqm. 105.7
(b) Ruled pointing sqm. 109.0

1030 Labour only for item no.1027, 1028 and 1029

(a) Flush pointing sqm. 98.5


(b) Ruled pointing sqm. 101.8

1031 Pointing on CR masonry with lime surkhi mortar 1:2 (1 lime putty, 2
surkhi)
(a) Flush pointing sqm. 107.9
(b) Ruled pointing sqm. 110.8
(c) Raised and cut pointing sqm. 159.4

1032 Pointing on CR masonry with cement mortar 1:3 (1cement, 3 sand)

(a) Flush pointing sqm. 111.9


(b) Ruled pointing sqm. 114.8
(c) Raised and cut pointing sqm. 166.0

1033 Pointing on CR masonry with cement mortar 1:4(1cement, 4sand)

(a) Flush pointing sqm. 110.4


(b) Ruled pointing sqm. 113.4
(c) Raised and cut pointing sqm. 163.6

1034 Labour only for item no.1031, 1032 and 1033

RES - NIC MPSU 10 - PLASTERING AND POINTING Page 4 of 6


Page 45 of 132

Code Description Unit Rate (Rs.)

(a) Flush pointing sqm. 94.5


(b) Ruled pointing sqm. 97.1
(c) Raised and cut pointing sqm. 145.7

1035 Pointing on random rubble masonry or uncoursed stone masonry with lime
surkhi mortar 1:2 (1lime putty, 2surhki)
(a) Flush pointing sqm. 124.6
(b) Ruled pointing sqm. 128.4
(c) Raised and cut pointing sqm. 195.6

1036 Pointing on random rubble masonry or uncoursed stone masonry with


cement mortar 1:3 (1cement, 3sand)
(a) Flush pointing sqm. 128.1
(b) Ruled pointing sqm. 132.4
(c) Raised and cut pointing sqm. 202.2

1037 Pointing on random rubble masonry or uncoursed stone masonry with


cement mortar 1:4 (1cement, 4sand)
(a) Flush pointing sqm. 126.7
(b) Ruled pointing sqm. 131.0
(c) Raised and cut pointing sqm. 199.8

1038 Labour only for item no.1035, 1036 and 1037

(a) Flush pointing sqm. 111.1


(b) Ruled pointing sqm. 115.1
(c) Raised and cut pointing sqm. 181.6

1039 Pointing on stone slab ceiling with cement mortar 1:2 (1 cement, 2 sand)

(a) Flush pointing sqm. 42.4


(b) Ruled pointing sqm. 44.0

1040 Labour only for item no 1039

(a) Flush pointing sqm. 29.3


(b) Ruled pointing sqm. 30.7

1041 Pointing on flag stone flooring in

(a) In Cement mortar 1:2 (1cement, 2sand) sqm. 96.0


(b) In Cement mortar 1:3 (1cement, 3sand) sqm. 94.3

1042 Labour only for item no.1041 sqm. 71.0

1043 Extra over items pointing on walls for height more then 10m ground level sqm. 10.3
for every additional height of 5m or part there off.
1044 Providing throating or plaster drip and moulding to R.C.C. chhajja. RM 25.6

1045 15mm thick plain cement mortar bands upto 300mm in width with cement
mortar 1:4 (1 cement, 4sand)
(a) Flush band sqm. 23.6

RES - NIC MPSU 10 - PLASTERING AND POINTING Page 5 of 6


Page 46 of 132

Code Description Unit Rate (Rs.)

1045 15mm thick plain cement mortar bands upto 300mm in width with cement
mortar 1:4 (1 cement, 4sand)
(b) Sunk band sqm. 25.6
(c) Raised band sqm. 28.9

1046 15mm thick plain cement mortar bands above 300mm in width with
cement mortar 1:4 (1cement, 4sand)
(a) Flush band sqm. 183.1
(b) Sunk band sqm. 203.0
(c) Raised band sqm. 236.3

1047 20mm thick plain cement mortar band upto 300mm in width with cement
mortar 1:4 (1cement, 4sand)
(a) Flush band RM 27.1
(b) Sunk band RM 29.1
(c) Raised band RM 32.4

1048 20mm thick plain cement mortar band above 300mm in width with cement
mortar 1:4 (1cement, 4sand)
(a) Flush band sqm. 216.1
(b) Sunk band sqm. 236.1
(c) Raised band sqm. 269.3

1049 Deleted ---- ----

RES - NIC MPSU 10 - PLASTERING AND POINTING Page 6 of 6


Page 47 of 132
11 - ROOFING
NOTES:
11.1 No seperate payment for lead and lift shall be permissible unless otherwise specified.
11.2 Rates for AC or GI sheet roofing are inclusive of all necessary overlaps and wastage
in cutting and of all standard screws, nuts, washers, bolts and patent J-hooks, bolts or other
fasteners required as per specification for proper fixing of the roof.
11.3. The following Indian Standards may be referred to -
I.S. NO. Title
73-1961 Paving bitumen (revised) (with amendment No.1)
277-1977 Galvanised steel sheets (plain and corrugated) (third revision)
459-1970 Unreinforced corrugated and semi-corrugated asbestos cement sheets
(second revision) (with amendment no.1)
654-1972 Clay roofing tiles, Manglore pattern (second revision) (with amendment
no.1 to3) (reaffirmed 1979)
702-1961 Industrial bitumen (revised)
730-1978 Hook bolts for corrugated sheet roofing (second revision)
1322-1970 Bitumen felts for water proofing and damp-proofing (second revision)
1464-1973 Clay ridge an ceiling tiles(first revision) (with amendment no.1)
(reaffirmed 1979)
1580-1969 Bituminous compound for water proofing and caulking purposes (first
revision) (with amendment no.1 and 2)
2115-1980 Code of practice for flat roof finish and mud phuska (second revision)
2527-1963 Code of practice for fixing rain-water gutters and down pipes for roof
drainage.
2645-1975 Integral cement water proofing compounds (first revision)
2690 Burnt clay flat terracing tiles.
2690(Pt.i)-1975 Machine made (first revision)
2690(Pt.ii)-1975 Hand made (first revision)
2858-1964 Code of practice for roofing with Manglore tiles.
3007 Code of practice for laying of asbestos cement sheets.
3007(Pt.i)-1964 Corrugated sheets.
3007(Pt.ii)-1965 Semi-corrugated sheets.
1346-1976 Code of practice for water proofing of roofs with bitumen felts (second
revision)
3036-1980 Code of practice for laying lime concrete for a waterproofed roof finish
(first revision)
3037-1965 Bitumen mastic for use in waterproofing of roofs.
3067-1966 Code of practice for general design, details and preparatory work for damp
proofing and water proofing of buildings.
3384-1965 Bitumen primer for use in water proofing and damp-proofing (with
amendment no.1)
3978-1967 Code of practice for manufacture of burnt clay Manglore pattern roofing
tiles (reaffirmed 1979)
4365-1967 Code of practice for application of bitumen mastic for water proofing of
roofs.
8869-1978 Washers for corrugated sheet roofing

Code Description Unit Rate (Rs.)

RES - NIC MPSU 11 - ROOFING Page 1 of 4


Page 48 of 132

Code Description Unit Rate (Rs.)

1101 Providing corrugated C.I. sheet of class III roofing fixed with galvanised
iron J or L hooks bolts and nuts 8mm diameter with bitumen and G.I.
limpet washers or with complete excluding the cost of purlins, rafters and
trusses.
(a) 0.63 mm thick sheet. sqm. 532.3
(b) 0.80 mm thick sheet. sqm. 640.7

1102 Labour only for item no. 1101 sqm. 46.2

1103 Providing ridges or hips 600mm over all in plain G.I. sheet class III fixed
with galvanised iron J or L hooks bolts and nuts 8mm diameter G.I. limpet
bitumen washers complete.
(a) 0.63 mm thick sheet. RM 404.5
(b) 0.80 mm thick sheet. RM 461.7

1104 Providing valleys 900mm over all in plain1.6mm thick G.I. sheet class III RM 873.3
fixed with galvanised iron J or L hooks bolts and nuts 8mm diameter G.I.
limpet bitumen washers complete.
1105 Labour only for item no.1103 and 1104 RM 161.2

1106 Providing 6mm thick corrugated asbestos cement sheets roofing fixed with sqm. 278.0
galvanised iron J or L hooks bolts and nuts 8mm dia. G.I. plain and
bitumen washer complete excluding the cost of purlines rafters and
trusses.
1107 Labour only for item no.1106 sqm. 56.7

1108 Providing and fixing ridges hips in asbestos cement sheet roofing with G.I.
J or L hooks bolts and nuts 8mm dia. G.I. plain and bitumen washer
complete .
(a) Close fitting adjustable ridge RM 324.8
(b) Unserrated adjustable hips. RM 268.5

1109 Labour only for item no.1108 RM 37.5

1110 Tiled roofing with Mangalore tiles, including sal, bija, haldu or saj battens sqm. 273.2
of size 50mm X 25mm but excluding ridge and hip tiles.
1111 Labour only for item no.1110 sqm. 141.6

1112 Tiled roofing with Mangalore tiles, excluding hipes, ridges and battens sqm. 190.3

1113 Labour only for item no.1112 sqm. 67.7

1114 Providing and fixing Manglore hipes and ridge tiles RM 127.7

1115 Labour only for item no.1114 RM 27.9

1116 Providing and laying single Allahabad tiles without battens but including sqm. 252.0
hip and ridge tiles.
1117 Labour only for item no.1116 sqm. 105.6

1118 Providing and fixing Allahabad hipes and ridge tiles RM 77.3

1119 Labour only for item no.1118 RM 27.9

RES - NIC MPSU 11 - ROOFING Page 2 of 4


Page 49 of 132

Code Description Unit Rate (Rs.)

1120 Providing stone slab roofing and laying in cement mortar 1:4 (1cement,
4sand) over R.S. joists or R.C.C. battens (R.S. joists and R.C.C. battens to
be paid separately) including pointing the exposed joints with the same
mortar complete.
(a) Red stone slab 40 mm thick. sqm. 291.0
(b) Red stone slab 50 mm thick. sqm. 339.2

1121 Labour only for item no.1120

(a) Red stone slab 40 mm thick. sqm. 149.0


(b) Red stone slab 50 mm thick. sqm. 186.7

1122 Lime concrete terracing on roofing's average thickness 100mm laid to fall sqm. 450.1
with 25mm nominal size brick ballast and 50% lime mortar 1:2 (1lime
putty, 2surkhi)(rammed and beaten with split bamboos and wooden the
thappies till the surface is hardened) and well finished with gur and
belwater treatment including rounding of junctions with parapets, curing
etc. complete.
1123 Labour only for item no.1122 sqm. 320.6

1124 Painting top of roofs with bitumen of approved quality 170kg/ 100sqm sqm. 378.2
impregnated with a coat of course sand at 0.60cum per 100sqm including
cleaning the slab surface with brushes and finally with a piece of cloth
lightly soaked in kerosene oil complete.
1125 Labour only for item no.1124 sqm. 18.1

1126 Grading roof for water proofing treatment.

(a) Lime concrete with 20 mm nominal size brick aggregate and 50% cum 4091.8
lime mortar 1:2 (1 lime putty, 2 surkhi)
(b) Cement mortar 1:3 cum 5741.3

1127 Labour only for item no.1126

(a) Lime concrete with 20 mm nominal size brick aggregate and 50% cum 3206.4
lime mortar 1:2 (1 lime putty, 2 surkhi)
(b) Cement mortar 1:3 cum 2702.9

1128 Providing and laying single country tiles (without battens) complete. sqm. 135.5

1129 Labour only for item no.1128 sqm. 62.7

1130 Providing and laying single country tiles on split bamboo battens. sqm. 452.6

1131 Labour only for item no.1130 sqm. 96.0

1132 Add for double country tilling in item no. 1128 & 1130 sqm. 135.5

1133 Add for labour double country tilling in item no. 1129 & 1131 sqm. 62.7

1134 Providing and laying single wheel tiling without battens sqm. 115.3

1135 Labour only for item no.1134 sqm. 80.3

1136 Centering and shuttering for arch roof including all lead and lift. (for low sqm. 79.6
cost House)

RES - NIC MPSU 11 - ROOFING Page 3 of 4


Page 50 of 132

Code Description Unit Rate (Rs.)

1137 Providing and fixing of full round country tiles (Guna tiles) in position sqm. 467.8
including lock rail gap cover with cement mortar 1:3 with water proofing
compound and plaster with chicken mess curing etc. complete. (for low
cost House)
1138 Providing and fixing of broken ceremic tiles with neat cement, curing etc. sqm. 255.1
(for low cost House)
1139 Providing and fixing cut stone slab (chisel dressed) for roofs including cum 8327.8
flush pointing of the bottom in C.M. 1:3 (1cement, 3sand) and filling the
joints in C.M. 1:4 (1cement, 4sand) including fixing in chased grooves in
walls, curing etc. complete.
1140 Labour only for item 1139 cum 3733.4

1141 Providing & fixing of precoated galvanised iron profile sheets (size,shape sqm. 495.6
& pitch of corrugation as approved by engineer in charge) 0.5mm +/- 5%
total coated thickness(TCT) thick zinc coating 120 gsm as per IS:277 in
240mpa steel grade,5-7 microns appoxy primer on both side of the sheet
and polyester top coat 15-18 microns.Sheet should have protective guard
film of 25 microns min. to avoid scratches while transportation and should
be supplied in single length up to 12 mtr or as desired by
engineer-in-charge.The sheet shall be fixed using self drilling / self
tapping screws of size 5.5x55mm with EPDM seal or with polymer coated
J or L hooks,bolts and nuts 8mm dia. with bitumen and G.I. limpet
washers or with G.I. limpet washers filled with white lead complete upto
any pitch in horizontal/vertical or curved surfaces excluding the cost of
purlins, rafters and trusses and i/c cutting to size and shape wherever
required.
1142 Providing & fixing of precoated galvanised steel sheet roofing accessories RM 490.2
0.5mm +/- 5% total coated thickness(TCT) zinc coating 120 gsm as per
IS:277 in 240mpa steel grade,5-7 microns appoxy primer on both side of
the sheet and polyester top coat 15-18 microns. using self drilling / self
tapping screws of size 5.5x55mm with EPDM seal or with polymer coated
J or L hooks,bolts and nuts 8mm dia. and or G.I. seam bolts and nuts,G.I.
plain and bitumen washers complete.
Ridges plain (500 - 600mm)
1143 Providing & fixing of precoated galvanised steel sheet roofing accessories RM 661.7
0.5mm +/- 5% total coated thickness(TCT) zinc coating 120 gsm as per
IS:277 in 240mpa steel grade,5-7 microns appoxy primer on both side of
the sheet and polyester top coat 15-18 microns. using self drilling / self
tapping screws of size 5.5x55mm with EPDM seal or with polymer coated
J or L hooks,bolts and nuts 8mm dia. and or G.I. seam bolts and nuts,G.I.
plain and bitumen washers complete. Gutter ( 600mm
over all girth).

RES - NIC MPSU 11 - ROOFING Page 4 of 4


Page 51 of 132
12 - PAVING, PITCHING AND FLOORING
NOTES:
12.1 The rates include -
(a) Leads and lifts of all matrerials unless otherwise specified.
(b) The cost of materials in which water includes.
(c) The cost of mixing motor, curing and scaffolding etc.
12.2. No deduction for voids shall be made from the gross measurements of pitching.
12.3. For cement concrete floors laying shall be done on the alternate bay system in panels
no dimension of which is to exceeds 1.8m and not more than 3 Sqm. atleast 48 hrs shall
lapse before commencing the concreting of alternatee bays, care shall be taken to ensure
that the edges of previously laid bays are not broken by careless tamping.
12.4. Mosaic/ Terrazo Tiles - Where the average size of chips are 6mm and below this
shall be termed as 'Mosaic tiles' and where the average size of chips is more than 6 mm
these shall be termed as 'Terrazo tiles '
12.5. The shade of cement slurry required for floating and striking joints shall be of the
same shade as those of tiles (Mosaic/ Terrazo/ Glazed vitreous)
12.6. Measurements - Length and breadth shall be measured correct to a cm and it area as
laid shall be calculated in sqm correct to two places of decimal. Length and breadth shall
be measured before laying skirting dado or wall plaster. No deduction shall be made nor
extra paid for any opening in the floor, for area upto 0.10sqm.
12.7 No seperate payment for lead and lift shall be permissible unless otherwise specified.
12.8 The following Indian Standards may be referred to -
IS No. Title
1237-1980 Cement concrete flooring tiles (first revision)
1443-1972 Code of practice for laying and finishing of cement concrete flooring tiles
(first revision)
2114-1962 Code of practice for laying in-situ terrazo floor finish (with amendment No.1)
2571-1970 Code of practice for laying in-situ cement concrete flooring (first revision)
Code Description Unit Rate (Rs.)

1201 Rammed moorum flooring cum 257.1

1202 Labour only for item no.1201 cum 74.0

1203 25mm thick mud flooring smoothing and cow dung leeping sqm. 52.2

1204 Hammer dressed 15cm thick stone paving laid in camber with 20mm lime sqm. 541.9
mortar (1:2) bedding and cement pointing in cement mortar 1:3 for
roadways.
1205 Labour only for item no.1204 sqm. 363.7

1206 Hammer dressed 20cm thick stone paving laid in camber with 20mm lime sqm. 626.3
mortar (1:2) bedding and cement pointing in cement mortar 1:3 for
roadways.
1207 Labour only for item no.1206 sqm. 415.6

1208 Hammer dressed 26cm thick stone paving laid in camber with 20mm lime sqm. 782.0
mortar (1:2) bedding and cement pointing in cement mortar 1:3 for
roadways.
1209 Labour only for item no.1208 sqm. 519.5

RES - NIC MPSU 12 - PAVING, PITCHING AND FLOORING Page 1 of 6


Page 52 of 132

Code Description Unit Rate (Rs.)

1210 Rough chisel dressed sand stone flooring over 20mm average thick base of
cement mortar 1:5 (1cement, 5sand) with joints finished flush (Area of
each stone should not be less than 0.20 Sqm.)
(a) With 25 mm thick stone sqm. 358.6
(b) With 40 mm thick stone sqm. 378.3

1211 Labour only for item no.1210 sqm. 187.9

1212 Fine dressed stone slab flooring over 20mm average thick base of cement
mortar 1:5 (1cement, 5sand) with joints finished flush.(Area of each stone
should not be less than 0.20 Sqm.)
(a) With 25 mm thick stone sqm. 898.0
(b) With 40 mm thick stone sqm. 917.8

1213 Labour only for item no.1212 sqm. 727.4

1214 Fine dressed rubbed stone flooring over 20mm average thick base of
cement mortar (1:5) i/c pointing C.M. (1:2) with admixture of pigment to
mach the shade of stone. (Area of each stone should not be less than 0.20
Sqm.)
(a) With 25 mm thick stone sqm. 1197.2
(b) With 40 mm thick stone sqm. 1216.9

1215 Labour only for item no.1214 sqm. 1014.2

1216 Extra for nosing in steps and treads of rough dressed sand stone slab. RM 34.1

1217 Extra for nosing in steps in treads with fine dressed and rubbed sand stone RM 231.4
slab.
1218 40mm cement concrete flooring with 25mm under layer of cement sqm. 293.0
concrete 1:3:6 (1cement, 3sand, 6stone aggregate of size 12.5mm and
below) and 15mm wearing (1cement, 2 to 3 stone aggregate of size
4.75mm and below) laid in interval with base course and finished with a
floating coat of neat cement.
1219 Labour only for item no.1218 sqm. 195.7

1220 Cement concrete flooring 1:2:4 (1cement, 2sand, 4graded stone aggregate,
20mm nominal size) laid in one layer and finished with floating coat of
neat cement.
(a) 40 mm thick. sqm. 213.4
(b) Deleted ....

1221 Labour only for item no.1220

(a) 40 mm thick sqm. 115.2


(b) Deleted ....

1222 Cement concrete pavement (25mm to 50mm thick) with 1:2:4 (1cement, cum 3343.7
2sand, 4graded stone aggregate 20mm nominal size) i/c finished with
floating coat of neat cement.
1223 Labour only for item no.1222 cum 886.6

1224 Extra for making cheques of approved pattern on cement concrete floors, sqm. 25.6
steps, landing, pavement etc.

RES - NIC MPSU 12 - PAVING, PITCHING AND FLOORING Page 2 of 6


Page 53 of 132

Code Description Unit Rate (Rs.)

1225 15mm cement plaster skirting upto 30cm height with cement mortar 1:3 (1 sqm. 207.9
cement, 3 sand) with a floating coat of neat cement i/c rounding of
junction with floor.
1226 40mm thick marble chip flooring rubbed and polished to granolithic
finish, under layer 32mm thick c.c. 1:2:4 with 10mm metal and top 8mm
thick with white black or white and black marble chip of nominal size laid
in cement marble powder mix 3:1 in proportion of 4:7 (4cement marble
powder mix, 7 marble chips by vol.)
(a) Dark shade pigment with ordinary cement (in top layer only). sqm. 675.9
(b) Light shade pigment with white cement (in top layer only). sqm. 677.6

1227 Labour only for item no.1226 sqm. 516.1

1228 Extra rate for providing and fixing Aluminium strips 40mm wide 1.5mm RM 58.2
thick painted with protective coat of bitumen in joints of floors
1229 Extra for providing and fixing glass strips in joints of floors

(a) 40 mm wide 4 mm thick. RM 23.6


(b) 40 mm wide 6 mm thick. RM 27.1

1230 Extra rate for terrazzo flooring laid as floor borders, margins and similar sqm. 19.0
band exceeding 7.5cm but not exceeding 30cm in width.
1231 Extra rate for laying terrazzo flooring on staircase treads not exceeding sqm. 28.2
30cm in width. i/c cost of forming nose etc.
1232 Precast cement concrete tiles 20mm thick with aggregate of size upto 6mm
laid in floors, treads of steps and landing on 20mm thick bed of cement
mortar 1:6 (1cement, 6sand) jointed with neat cement slurry with pigment
to match the shade of the tiles complete with precast tiles.
(a) Light shades using white cement. sqm. 422.9
(b) Medium shades using approximately 50% white cement and 50% sqm. 397.3
ordinary cement.
(c) Dark shades using ordinary cement. sqm. 370.7

1233 Labour only for item no.1232 sqm. 143.6

1234 Extra if precast cement concrete tiles are laid in treads of steps not sqm. 27.9
exceeding 30cm in width.
1235 Precast cement concrete tiles 20mm thick with aggregate of size upto 6mm
in skirting and rises of steps not exceeding 30cm in height on 12mm thick
cement plasters 1:3 (1cement, 3sand) jointed with neat cement slurry
complete with tiles.
(a) Light shades using white cement. sqm. 522.8
(b) Medium shades using approximately 50% white cement and 50% sqm. 640.8
ordinary cement.
(c) Dark shades using ordinary cement. sqm. 449.6

1236 Labour only for item no.1235 sqm. 216.1

1237 Precast terrazzo tiles 20mm thick with white, black or white and black
marble chips of size upto 6mm laid in floors, treads of steps and landing
on a bed of 25mm average thickness and of lime mortar 1:1:1 (1lime
putty, 1surkhi, 1sand) jointed with neat cement slurry mixed with pigment
to match the shade of the tiles i/c rubbing and polishing complete with
precast titles.

RES - NIC MPSU 12 - PAVING, PITCHING AND FLOORING Page 3 of 6


Page 54 of 132

Code Description Unit Rate (Rs.)

(a) Light shade using white cement. sqm. 686.1


(b) Medium shades using approximately 50% white cement and 50% sqm. 672.1
ordinary cement.
(c) Dark shades using ordinary cement. sqm. 638.9

1238 Labour only for item no.1237 sqm. 347.4

1239 Extra if terrazzo tiles are laid in treads of steps not exceeding 30cm in sqm. 34.0
width.
1240 Precast terrazzo tiles 20mm thick marble chip of size upto 6mm skirting
and risers of steps not exceeding 30cm in height on 10mm thick cement
plaster 1:3 jointed with neat cement slurry i/c rubbing and polishing
complete with precast titles.
(a) Light shade using white cement. sqm. 813.9
(b) Medium shades using approximately 50% white cement and 50% sqm. 796.7
ordinary cement.
(c) Dark shades using ordinary cement. sqm. 716.6

1241 Labour only for item no.1240 sqm. 454.4

1242 Chequered precast cement concrete tiles 22mm thick with aggregate of
size upto 6mm in floors, treads of steps and landing on 20mm thick bed of
cement mortar 1:6 (1cement, 6 sand) jointed with neat cement slurry with
pigment to match the shade of the tiles.
(a) Light shades using white cement. sqm. 568.0
(b) Medium shades using approximately 50% white cement and 50% sqm. 544.0
ordinary cement.
(c) Dark shades using ordinary cement. sqm. 515.8

1243 Labour only for item no. 1242 sqm. 143.6

1244 Extra rate rubbing and polishing C.C.. tiles in flooring skirting or dado. sqm. 156.8

1245 White glazed tiles 6mm thick in flooring, treads of steps and landings laid sqm. 895.2
on a bed of 12mm thick cement mortar 1:3 finished with flush pointing in
white cement.
1246 Labour only for item no.1245 sqm. 507.9

1247 Marble stone slab flooring over 20mm average thick base of C.M. 1:6
with grey cement including rubbing polishing etc. complete. (Area of each
stone should not be less than 0.20 Sqm.)
(a) Marble slab 25 mm thick. sqm. 1988.3
(b) Marble slab 30 mm thick. sqm. 2178.9

1248 Labour only for item no.1247 sqm. 1288.5

1249 25mm thick marble tiles in risers and treads of steps, skirting dado walls sqm. 2096.7
and pillar laid on 10mm thick base of C.M. 1:3 and jointed with grey
cement slurry including rubbing polishing etc. complete.
1250 Labour only for item no.1249 sqm. 1435.5

1251 Extra if pigment is used in the cement slurry to match the shade of the sqm. 3.7
marbel slabs.
1252 Add extra if white cement slurry is used instead of grey cement slurry in sqm. 6.8
joints of marbel stone flooring or tiles for all thickness

RES - NIC MPSU 12 - PAVING, PITCHING AND FLOORING Page 4 of 6


Page 55 of 132

Code Description Unit Rate (Rs.)

1253 Extra for nosing in marbel stone for treads. RM 195.7

1254 Kota stone slab flooring over 20mm thick base of C.M. 1:6 laid over and
jointed with grey cement slurry mixed with pigment to match the shade of
slab including grinding, rubbing & polishing etc. complete. (Area of each
stone should not be less than 0.20 Sqm.)
(a) 25 mm thick. sqm. 1108.7
(b) 30 mm thick . sqm. 1270.1
(c) 40 mm thick. sqm. 1343.0

1255 Labour only for item no.1254

(a) 25 mm thick. sqm. 799.9


(b) 30 mm thick. sqm. 905.9
(c) 40 mm thick. sqm. 923.5

1256 Kota stone slab/Cuddapah stone slab 25mm thick in risers and treads of sqm. 1206.6
steps, skirting dado and pillar laid in 12mm thick C.M. 1:3 and jointed
with grey cement slurry mixed with pigment to match the shade of slab
including rubbing polishing etc. complete.
1257 Labour only for item no.1256 sqm. 905.6

1258 Linoleum covering to floors plain or curved laid with approved adhesive sqm. 414.1
on upper floor i/c stretching cutting and fitting complete 3.2mm thick
1259 Labour only for item no.1258 sqm. 33.2

1260 15mm cement concrete topping 1:2 to 3 (1cement, 2-3stone aggregate sqm. 135.3
4.75mm and below by volume) laid over and finished monolithic with
structural slab.
1261 Labour only for item no.1260 sqm. 81.2

1262 20mm cement concrete toping (1 cement, 2-3 stone aggregate 4.75mm and sqm. 164.3
below by volume) laid over and finished monolithic with base concrete.
1263 Labour only for item no. 1262 sqm. 93.5

1264 25mm cement concrete toping 1:2:4 (1cement, 2sand, 4graded stone sqm. 160.4
aggregate 12.5mm nominal size) finished with floating coat of neat cement
(base concrete to be paid separately)
1265 Labour only for item no.1264 sqm. 97.2

1266 Second class dry brick flooring i/c filling joints with fine sand. sqm. 280.5

1267 Labour only for item no.1266 sqm. 92.5

1268 Second class brick flooring laid dry grouted with C.M. 1:6 i/c finishing the sqm. 311.6
joints flush.
1269 Labour only for item no.1268 sqm. 94.4

1270 22cm thick grouted stone pitching (without quarry spalls) with individual sqm. 600.1
stones of 22cm depth in minimum size 0.014cum grouting in cement
mortar 1:6
1271 Labour only for item no.1270 sqm. 298.0

RES - NIC MPSU 12 - PAVING, PITCHING AND FLOORING Page 5 of 6


Page 56 of 132

Code Description Unit Rate (Rs.)

1272 22cm thick dry stone pitching (without quarry spalls) with individual stone sqm. 278.5
of 22cm depth and minimum size 0.014
1273 Labour only for item no.1272 sqm. 185.0

1274 22cm thick dry stone picked up boulder pitching i/c picking of boulder sqm. 227.8
with individual size of 22cm depth.
1275 Add extra item no. 1274 for quarried boulder pitching. sqm. 180.0

1276 Labour only for item no.1274 sqm. 96.4

1277 Providing stone chips under stone pitching sqm. 405.1

1278 Labour only for item no.1277 sqm. 65.2

1279 Hammer dressed 15cm thick stone paving laid in camber in sqm. 395.3
moorum bedding and filled with moorum mortar.
1280 Labour only for item no.1279 sqm. 311.7

1281 40 to 50mm thick flag stone flooring laid over 20mm thick cement mortar sqm. 384.3
(1:6) bedding I/n cement pointing in cement mortar 1:3
1282 Labour only for item no.1281 sqm. 187.9

RES - NIC MPSU 12 - PAVING, PITCHING AND FLOORING Page 6 of 6


Page 57 of 132
13 - PAINTING, WASHING AND DISTEMPERING
NOTES :
13.1 Rates include :-
(a) All leads and lifts of matrerials unless otherwise specified.
(b) Removing nails and making good holes cracks, patches etc. not exceeding 0.1sqm each
materials similar in composition to the surface to be prepared
(c) Removing cakes and scales of wash but not distemper
(d) Cost of scaffoldings and ladders (in case of completed items)
(e) Cost of cans, brushes, and other appliances required for the execution of work
(f) Thoroughly brooming the surface to remove all dirt, dust, mortar drops and other
foreign matter; and
(g) Protection of all places and things needing protection, cleaning by approved method,
removing all stains, splashing and droppings of every kind, from floors, glazing, furniture's
etc.
13.2 Before starting the distemper/ oil bound distemper/ painting etc. the contractor must
get the brand and quality approved by the Engineer-in-Charge, bring the full quantity of
approved brand and quality required for the work and remove the empty containers only
after the work is measured and checked.
13.3 (a) For oil bound distempering prior written permission of the Executive engineer is
required.
(b) For plastic emulsion water proofing cement paint (snocem or durocem) prior
written permission of the superintending Engineer is required.
13.4 Paints, oil, varnishes etc. of approved brand and manufacture shall be used. Ready
mixed paints as received from the manufacture without any admixture shall be used. If for
any reason, thinning is necessary in case of ready mixed paint, the brand of thinner of
recommended by the manufacture or as decided by the Engineer-in-Charge shall be used.
13.5 Approved paints, oils or varnishes shall be brought to the site of work in their original
container in sealed condition, the material shall be brought in at a time in adequate
quantities to suffice for the whole work or At least a fortnight's work.
13.6 Measurements-
I. Dimension shall be measured correct to the nearest cm. The area shall be calculated in
sqm correct to two places of decimal.
II. For jambs, soffits, sills, etc. for openings not exceeding 0.5sqm each in area for ends of
joists, beams, posts, girders, steps etc. not exceeding 0.5sqm in area, and for openings
Exceeding 0.5sqm and not exceeding 3sqm in area deduction and no addition shall be
made in the following manner-
(a) No deduction shall be made for ends of joists, beams, etc. and openings not exceeding
0.5sqm each and no addition shall be made for reveals, jambs, soffits, sills of these
openings for the finish around ends of joists, beams, posts etc.
(b)Deduction for opening exceeding 0.5sqm each shall be made for reveals, jambs, soffits,
sills etc. of these openings -
(i) when both faces of wall are provided with the same finish, deduction shall be made for
one face only.
(ii) When each face of wall is provided with a different finish, deduction shall be made for
the side on which width of reveals is less than that other side but no deduction shall be
made on the other side ; where widths of reveals on both faces of wall are equal, deduction
of 50percent of area of opening of each face shall be made from area of finish.
(iii) When only one face is treated, and other face is not treated, full deduction shall be
made if width of reveal on the treated side is less than that on the untreated side, but if
Page 58 of 132
width of reveals is equal or more then that on the side, untreated neither deduction for the
opening nor addition for reveals, jambs, soffits, sills etc. shall be made.
(iv) When width of door frame is equal to thickness of wall or is projecting beyond the
thickness of wall, full deduction for opening shall be made from each face of wall.
III. In case of opening of areas above 3sqm each deduction shall be made for opening, but
jambs, soffits and reveals shall be measured.
IV. No deduction shall be made for attachments, such as casings, conduit pipes, electric
wiring and the like.
V. Corrugated surfaces shall be measured flat as fixed and not girthed. Quantities so
measured shall be increased by the following percentage and the result shall be included in
general areas-
(a) Corrugated steel sheets 14 %
(b) Corrugated asbestos cement sheets 20 %
(c) Semi-corrugated asbestos cement sheet 10 %
VI. Cornices and other wall features when not picked out in a different finish/ colour, shall
be girthed and included area.
13.7 No seperate payment for lead and lift shall be permissible unless otherwise specified.
13.8 The following Indian standard may be referred to -
IS No. Title
55-1970 Ultramarine blue for paints (First revision) (reaffirmed 1977)
261-1966 Copper sulphate (first revision) (with amendment no.1) ( reaffirmed
1977)
427-1965 Distemper, dry, colour as required (revised)
428-1969 Distemper, oil emulsion, colour as required (first revision) ( with
amendment no.1)
712-1973 Building lime (second revision)
5410-1969 Cement paint, colour as required (with amendment no.1) plastic
emulsion paint.
5411-5411 Plastic emulsion paint.
5411(pt i)- 1969 Part i-for interior use.
5411(pt ii)-196 Part ii - For exterior use.
6278-197 Code of practice for white washing and colour washing
75-1973 Linseed Oil, raw and refined (second revision) (with amendment no.1)
(reaffirmed1979)
77-1976 Linseed oil, boiled, for paints (second revision)
102-1962 Ready mixed paint, brushing red lead, settling priming (revised) (with
amendment no.1) (reaffirmed 1977)
104-1979 Ready mixed paint, brushing, zinc, chrome ,priming (second revision)
109-1968 Ready mixed paint, brushing, priming, plaster, to Indian Standard colour
no.361 light stone and no. 631 light grey (first revision) (with amendment no.1)
(reaffirmed 1976)
133-1979 Enamel, interior (a) under coating, (b) finishing (second revision)
137-1995 Ready mixed paint, brushing matt or egg - shell, flat, finishing interior to
Indian standard colour as required (revised) (with amendment no.1) (reaffirmed 1976)
158-1981 Ready mixed paint, brushing, bituminous, black lead-free, acid, alkali
and heat and heat resisting (third revision)
218-1961 Creosote and anthracene oil for use as wood preservatives (revised)
290-1981 Coal tar black paint (revised) (reaffirmed 1976)
337-1975 Varnish, mixing, interior (first revision)
340-1978 Varnish, mixing (first revision)
Page 59 of 132
341-1973 Black Japan, types A, B and C (first revision) (reaffirmed 19 79)
345-1952 Wood filler, transparent, liquid (with amendment no.1and 2)
(reaffirmed 1976)
348-1968 French polish (first revision) (with amendment no.1and 2) (reaffirmed
1976)
430-1972 Paint remover, solvent type, non-flammable (second revision)
487-1976 Brush, paint and varnish (I) oval, ferrule bound and (II) round, ferrule
bound (second revision)
524-1968 Varnish, finishing, exterior, syntgetic (first revision) (with amendment
no.1) (reaffirmed 1976)
525-1968 Varnish, finishing, exterior, an general purpose (first revision) (with
amendment no.1) (reaffirmed 1976)
533-1973 Gum spirit of turpentine (oil of turpentine) (first revision) (with
amendment no.1and 2) (reaffirmed 1978 )
1103-1971 Brushes artist's (second revision) (with amendment no.1)
1104-1968 Brushes, lettering (lettering) (reaffirmed 1976)
1303-1963 Glossary of terms relating to paints (revised)
1477 Code of practice for painting of ferrous metals in buildings
1477-(pt.i)-1971 Pre-treatment (first revision) (reaffirmed 1979 )
1477(pt.ii)-1971 Painting (first revision) (reaffirmed 1979 )
2338 Code of practice for finishing of wood and wood based materials.
2338 (Pt.i)-1967 Operations of workmanship.
2338 ( Pt.ii )-1967 Schedules.
2339-1963 Aluminium paint for general purposes, in dual container (with
amendment no.1) (reaffirmed 1976)
2395 Code of practice for painting concrete, masonry and plaster surfaces.
2395( Pt.i)-1966 Operations of workmanship.
2395(Pt.ii)-1966 Schedules.
2524 Code of practice for painting of non-ferrous metals
2524(Pt.i)-1968 Pre-treatment.
2524(Pt.ii)-1968 Painting.
2074-1979 Ready mixed paint, air drying, red oxide zinc oxide, zinc chrome,
priming (first revision)
2932-1974 Enamel, synthetic, exterior (a) under coating (b) finishing (first revision)
(with amendment no.1)
2933-1975 Enamel, exterior (a) under coating (b) finishing (first revision)
3140-1965 Code of practice for painting asbestos cement building products.
3536-1966 Ready mixed paint, brushing wood primer, pink (with amendment no.1)
(reaffirmed 1976)
3585-1966 Ready mixed paint, aluminium, brushing, priming water resistant for
wood work (with amendment no.1) (reaffirmed 1976)
5411 Plastic emulsion paint.
5411(Pt.i)-1974 For interior use (first revision) (with amendment no.1)
5660-1970 Ready mixed paint, brushing aluminium, red oxide primer (reaffirmed
1976)
6005-1970 Code of prectice for phosphating of iron and steel (reaffirmed 1979)
SP 1650-1973 Standard colours for building decorative finishes (with supplement)

Code Description Unit Rate (Rs.)

RES - NIC MPSU 13 - PAINTING, WASHING AND DISTEMPERING Page 3 of 7


Page 60 of 132

Code Description Unit Rate (Rs.)

1301 Removing old paint or polish from wood and wood based surfaces with sqm. 31.9
caustic soda solution and making the surface even.
1302 Removing old paint from steel and other metal surfaces and making the sqm. 59.9
surface even with hand seraping.
1303 Removing white wash or colour wash by steel wire brushing and/or sqm. 5.9
scraping; sand papering and preparing the wall surface smooth including
necessary repairs to scratches complete.
1304 Removing dry or oil bound distemper by washing and scraping and sand sqm. 13.2
papering the wall surface smooth including necessary repairs to scratches
complete.
1305 Washing and cleaning of decorated wall surfaces with soap, soda and sqm. 2.5
water.
1306 Extra over item 1305 for cleaning the old plastered ceiling and/or sloping sqm. 2.8
roofs with soap, soda and water.
1307 White washing whith lime on undecorated wall surfaces (3coats) to give sqm. 13.2
an even shade including thoroughly broomed the surface to remove all
dirt, dust, mortar drops and other foreign matter.
1308 White washing whith lime on undecorated wall surfaces (two coats) to sqm. 9.0
give an even shade including thoroughly broomed the surface to remove
all dirt, dust, mortar drops and other foreign matter.
1309 White washing with lime on decorated wall surfaces (one coat) to give an sqm. 4.2
even shade including thoroughly brooming the surface to remove all dirt,
dust, mortar drops and loose scales of lime wash and other foreign matter.
1310 Labour only for

(a) For item no. 1307 sqm. 9.8


(b) For item no. 1308 sqm. 6.8
(c) For item no. 1309 sqm. 3.0

1311 Colour washing 2 coats over and including a primary coat of white sqm. 16.2
washing on undecorated wall surface.
1312 Colour washing 1 coats on decorated wall surface. sqm. 5.3

1313 Labour only for.

(a) For item no. 1311 sqm. 13.7


(b) For item no. 1312 sqm. 4.5

1314 Cement washing (Portland cement) 3 coats.

(a) Gray cement sqm. 22.6


(b) White cement sqm. 25.5

1315 Cement washing (Portland cement) 2 coats.

(a) Gray cement sqm. 15.0


(b) White cement sqm. 17.0

1316 Cement washing (Portland cement) 1 coats.

(a) Gray cement sqm. 7.5


(b) White cement sqm. 8.5

RES - NIC MPSU 13 - PAINTING, WASHING AND DISTEMPERING Page 4 of 7


Page 61 of 132

Code Description Unit Rate (Rs.)

1317 Labour only for

(a) For item no.1314 (a)(b) sqm. 21.1


(b) For item no.1315 (a)(b) sqm. 14.1
(c) For item no.1316 (a)(b) sqm. 7.0

1318 Snowcem or durocem painting of any shade

(a) 2 coats on new work sqm. 19.8


(b) 1 coats on old work sqm. 9.9

1319 Labour only for

(a) For item no.1318 (a) sqm. 13.5


(b) For item no.1318 (b) sqm. 6.8

1320 Distempering with dry distemper of approved brand and manufacture (two sqm. 49.3
coats) and of required shade on undecorated wall surfaces to give an even
shade, over and including priming coat of whiting after thoroughly
brushing the surface free from mortar dropping and other foreign matter
including preparing the surface even and sand papered smooth.
1321 Dry distemper of best quality of any shade 1 coat and old surface for sqm. 13.2
repairs etc.
1322 Labour only

(a) For item no.1320 sqm. 45.5


(b) For item no.1321 sqm. 11.4

1323 Oil bound distemper of approved quality of any shade two coats on new sqm. 74.2
works including priming coat.
1324 Oil bound distemper of best approved quality of any shade one coat on old sqm. 29.2
surface.
1325 Labour only for item no.1323 sqm. 57.3

1326 Labour only for item no.1324 sqm. 22.7

1327 Wood oiling to new work with double boiled linseed oil two coats. sqm. 28.1

1328 Wood oiling to old work with double boiled linseed oil one coat. sqm. 20.0

1329 Labour only for

(a) For item no.1327 sqm. 16.7


(b) For item no.1328 sqm. 13.1

1330 Varnishing two costs (excluding priming coat) on new wood and wood sqm. 82.6
based surfaces, under coating, with flatting varnish and finishing coat with
varnish to give an even surface including cleaning the surface of all dirt,
dust and sand papering so as to produce a smooth dry and matt surface.
1331 Varnishing one coat (excluding priming coat) on previoulsy varnished sqm. 37.2
wood and wood based surfaces to give an even surface including cleaning
the surface of all dirt, dust and sand papering so as to produce smooth, dry
and matt surface.

RES - NIC MPSU 13 - PAINTING, WASHING AND DISTEMPERING Page 5 of 7


Page 62 of 132

Code Description Unit Rate (Rs.)

1332 Labour only for

(a) For item no.1330 sqm. 65.3


(b) For item no.1331 sqm. 26.1

1333 Prime coat to wood, iron work or walls. sqm. 32.0

1334 Labour only for item no.1333 sqm. 21.8

1335 Painting with enamel paint, brushing, interior to give an even shade I/n
cleaning the surface of all dirt dust and other foreign matter on steel and
other metal surfaces.
(a) 3 coats sqm. 98.7
(b) 2 coats sqm. 70.7
(c) 1 coats sqm. 35.9

1336 Labour only for item no.1335

(a) 3 coats sqm. 60.9


(b) 2 coats sqm. 39.2
(c) 1 coats sqm. 21.8

1337 Painting two coat's (excluding priming coat) on new steel and other metal
surfaces with Aluminium paint, brushing to give an even shade including
cleaning the surface of all dirt, dust and other foreign matter.
(a) 2 coats sqm. 56.0
(b) 1 coats sqm. 33.4

1338 Labour only for item no.1337

(a) 2 coats sqm. 39.2


(b) 1 coats sqm. 26.1

1339 Spray painting 2 coats excluding priming coat on new steel and other sqm. 83.0
metal surface with enamel paint.
1340 Spray painting 1 coats excluding priming coat on new steel and other sqm. 52.7
metal surface with enamel paint.
1341 Labour only for

(a) For item no.1339 sqm. 52.9


(b) For item no.1340 sqm. 34.7

1342 Painting 1 coats excluding priming coat on previously painted steel and sqm. 45.0
other metal surface with enamel paint.
1343 Labour only for item no.1354 sqm. 26.1

1344 Coal tarring 2 coats on new wood and wood based surface . sqm. 24.8

1345 Coal tarring 1 coats on new wood and wood based surface. sqm. 14.2

1346 Labour only for

(a) For item no.1344 sqm. 13.5

RES - NIC MPSU 13 - PAINTING, WASHING AND DISTEMPERING Page 6 of 7


Page 63 of 132

Code Description Unit Rate (Rs.)

1346 Labour only for

(b) For item no.1345 sqm. 9.4

1347 Polishing with French polish two coats on new wood and wood based sqm. 133.0
surfaces to give an even surface including cleaning the surface of all dirt,
dust and sand papered smooth and including a coat of wood filler.
1348 Polishing with French polish one coat on new wood and wood based sqm. 67.3
surfaces to give an even surface including cleaning the surface of all dirt,
dust and sand papered smooth and including a coat of wood filler.
1349 Labour only for

(a) For item no.1347 sqm. 123.0


(b) For item no.1348 sqm. 61.5

1350 Floor polishing on Masonry or Concrete floors with wax polish of sqm. 31.0
approved brand and manufacture.
1351 Deleted ---- ----

RES - NIC MPSU 13 - PAINTING, WASHING AND DISTEMPERING Page 7 of 7


Page 64 of 132
14 - REPAIR TO BUILDING WORK
NOTES:
14.1 The rates include -
(a) All leads and lifts of matrerials unless otherwise specified.
(b) The cost of materials in which water includes.
(c) The cost of mixing motor, curing and scaffolding etc.
14.2 These rates are applicable to all types of buildings for all heights.

Code Description Unit Rate (Rs.)

1401 Providing and fixing small pieces (not exceeding 150cucm) for making
good where hinges etc have been removed from frames or joinery, etc.
(a) Sal wood. Each 51.0
(b) Bija wood Each 55.0

1402 Renewing Bars, stiles on rails, straight for joinery upto 50mm thick
including meters, haunchings, mortises, etc. and removing old defective
pieces.
(a) Sal wood. RM 199.2
(b) Bija wood RM 212.7

1403 Rewedging cramping joinery of any description with new wedges in glue
or white lead and repining including rehanging or refixing of shutters,
hinges or pivots excluding removing or dismantling.
(a) Not exceeding 1sqm per leaf of soft wood Each 254.0
(b) Not exceeding 1 sqm. per leaf for hard wood Each 382.6
(c) Exceeding 1 sqm.but not exceeding 2 sqm.per leaf for soft wood Each 382.6
(d) Exceeding 1 sqm.but not exceeding 2 sqm.per leaf for hard wood Each 508.1

1404 Making repairs to joinery at angles with & including 300mm x 25mm x nos. 53.0
3mm length of M.S. flat forged to shape and let into wood work, counter
sunk, drilled and screwed.
1405 Renewing wooden battens in roofing including making good the holes in
walls including removal of rubbish to the demping ground with in a lead
of 50metres.
(a) Bija wood battens cum 32912.6
(b) Sal wood battens cum 30163.8

1406 Providing and fixing M.S. fan clamps of 16mm dia mild steel in existing Each 185.5
RCC slab including cutting chase and making good.
1407 Removal of old broken glass panes (any thickness or size quality or sqm. 103.8
description) from wood frames, glazed with putty or fixed with beads.
1408 Supplying and fixing new wooden beads(fillets) wherever necessary.

(a) Second class teak wood. RM 23.6


(b) Sal wood wood. RM 19.9

1409 Renewal of old putty of glass panes. RM 20.3

1410 Refixing old glass panes bedded in putty and fixed with glazing pins. sqm. 263.9

1411 Refixing old glass panes with old wooden beads (excluding cost of beads sqm. 219.8

RES - NIC MPSU 14 - REPAIR TO BUILDING WORK Page 1 of 2


Page 65 of 132

Code Description Unit Rate (Rs.)

1412 Renewing tiles in patches in areas exceeding 10 tiles and not exceeding 5
sqm including removing old tiles, preparing surfaces and laying or setting
new or old tiles complete.
(a) Glazed tiles sqm. 538.7
(b) Cement tiles or Terrazzo tiles sqm. 416.8

1413 Cutting out cracks of roof terrace to V-Section, cleaning out wetting, RM 41.5
grouting with cement and sand slurry 1:3 (1 cement, 3 sand)
1414 Cutting out cracked of roof terrace to V-Section, cleaning out and filling RM 57.0
solidly with a hot mixture of bitumen and clean dry sand slurry 1:1 (1 by
weight)
1415 Dubbing out on old irregular walls average 10mm thick with.

(a) Cement mortar 1:3 (1Cement, 3Sand) sqm. 99.3


(b) Cement mortar 1:4 (1Cement, 4Sand) sqm. 86.9
(c) Cement mortar 1:6 (1Cement, 6Sand) sqm. 74.5

1416 Repairs to plaster in patches of 2.50 sqm and under and 10 to 15mm thick
including cutting the patch in proper shape and replastering the surfaces of
the walls including disposal of rubbish to the Camping ground within a
lead of 50 metres with.
(a) Lime mortar 1:2 (1Lime, 2Sand) sqm. 153.5
(b) Cement mortar 1:3 (1Cement, 3Sand) sqm. 179.3
(c) Cement mortar 1:4 (1Cement, 4Sand) sqm. 168.6
(d) Cement mortar 1:6 (1Cement, 6Sand) sqm. 158.0

1417 Turning tiles for repairs(single country, Allahabad or Manglore tiles) sqm. 14.8
excluding cost of tiles.
1418 Turning tiles for repairs(double country or Allahabad tiles) excluding cost sqm. 22.3
of tiles.
1419 Removing of old wornout hessian based felt treatment from roof and sqm. 15.7
parapet walls.
1420 Cleaning and brushing the surface. sqm. 4.7

1421 Preparing the base surface filling the cracks and pot holes whenever sqm. 17.5
necessary with cement mortar(1:3)
1422 Removing old plaster or edges, cleaning of joints and floor for new work sqm. 20.4
and disposal of unserviceable materials within 50m lead
1423 Cleaning of old joints, in required depth for new pointing or plastering and sqm. 17.2
disposal of unserviceable materials within 50m lead

RES - NIC MPSU 14 - REPAIR TO BUILDING WORK Page 2 of 2


Page 66 of 132
15 - DISMANTLING AND DEMOLISHING
NOTES:
15.1 The rates include -
(a) Removal of dismantled materials to a distance of 50 metres or upto the nearest R.E.S.
stores whichever is less as directed by Executive Engineer.
(b) Carefully removing, taking up or down the articles of the Structure without damage.
(c) Picking, cleaning, sorting out and stacking etc. of the un-serviceable and serviceable
material separately.
(d) Taking down walls with plaster, but the measurements will be exclusive of plaster
thickness, Mode of measurement will be as for masonry work.
(e) Removal of nails, spikes and screws from timber.
15.2. The rates for dismantling of roofs or upper storey, floors do not include dismantling
of roof supports such as beams and trusses.
15.3. The rates are applicable to all types of structures, Building and all floors and all
heights etc.
15.4. During dismantling every precaution shall be taken to prevent damage to any part of
the structure and also to adjoining structure which are to be left intact. Any such damage
which is due to carelessness will be made good by the contractor at his own expenses.
15.5 All quantities shall be measured before dismantling and recorded in measurement
book duly accepted by the contractor.
15.6. All the dismantled materials will form government property unless ordered
otherwise, in which case no payment shall be due to the contractor for removal.
15.7. In dismantling, the articles shall be carefully removed by hand where necessary and
lowered to the ground and not thrown. Iron and asbestos cement sheets, wood, planks etc.
shall be removed by taking out nails, screws and bolts with proper tools and not torn off by
forces.
Code Description Unit Rate (Rs.)

1501 Demolishing below G.L. upto 1 metre depth and disposal of unserviceable
materials within 100 metres lead.
(a) Lime concrete. cum 382.5
(b) Unreinforced cement concrete upto 15 cm thickness. cum 765.1
(c) Unreinforced cement concrete more then 15 cm thickness. cum 1530.1

1502 Demolition R.C.C. work below G.L. upto 1 metre depth including cum 1354.5
stacking of serviceable materials and disposal of unserviceable materials
within 100 metres lead.
1503 Extra over item 1502 for cutting steel bars in R.C.C. (Least sectional area sqm. 332.4
of R.C.C. work to be measured)
1504 Demolition above G.L. upto floor two level including disposal of
unserviceable materials within 100 metres lead.
(a) Lime concrete. cum 394.0
(b) Unreinforced cement concrete upto 15 cm thickness. cum 776.5
(c) Unreinforced cement concrete more then 15 cm thickness. cum 1541.6

1505 Demolishing RCC work above G.L. upto floor two level including cum 1368.1
disposal of unserviceable materials within 100 metres lead.
1506 Extra over item 1505 for cutting steel bars in R.C.C. work (Least sectional sqm. 332.4
area of R.C.C. work to be measured)

RES - NIC MPSU 15 - DISMANTLING AND DEMOLISHING Page 1 of 3


Page 67 of 132

Code Description Unit Rate (Rs.)

1507 Demolition of brick work below G.L. upto 1 metre depth including
stacking of serviceable materials and disposal of unserviceable materials
within 100 metres lead.
(a) In mud mortar . cum 351.2
(b) In lime mortar . cum 429.6
(c) In cement mortar . cum 1006.5

1508 Demolition of brick work above G.L. upto floor two level including
stacking of serviceable materials and disposal of unserviceable materials
within 100 metres lead.
(a) In mud mortar . cum 361.7
(b) In lime mortar . cum 442.4
(c) In cement mortar . cum 1021.6

1509 Extra over items1507& 1508 for removing mortar from and cleaning
bricks including removal of rubbish within 100 metres lead.
(a) Brick work in mud mortar. cum 664.1
(b) Brick work in lime mortar. cum 760.9
(c) Brick work in cement mortar. cum 947.3

1510 Demolition of stone masonry below G.L. upto 1 metre depth including
stacking of serviceable materials and disposal of unserviceable materials
within 100 metres lead.
(a) Rubble masonry in lime mortar . cum 429.6
(b) Rubble masonry in cement mortar. cum 1006.5

1511 Demolition of stone masonry above G.L. upto floor two level including
stacking of serviceable materials and disposal of unserviceable materials
within 100 metres lead.
(a) Rubble masonry in lime mortar . cum 442.4
(b) Rubble masonry in cement mortar . cum 1021.6
(c) Dressed stone in cement mortar . cum 1220.4

1512 Demolition of terrace upto floor two level including stacking of


serviceable materials and disposal of unserviceable materials within 100
metres lead.
(a) Brick tile covering. sqm. 39.4
(b) Mud phuska. cum 351.2

1513 Dismantling tiled floors laid in mortar upto floor two level including
stacking of serviceable materials and disposal of unserviceable materials
within 100 metres lead. (wooden\ concrete joists to be measured and paid
for separately)
(a) For thickness of tiles upto 25 mm . sqm. 29.4
(b) For thickness of tiles above 25 mm sqm. 41.4
(c) Stone slab floor sqm. 92.5

1514 Dismantling sheet roofing including ridges, hips, valleys, gutters etc.
stacking the serviceable materials and disposal of unserviceable materials
within 100 metres lead.
(a) G.I. sheet roofing sqm. 56.8

RES - NIC MPSU 15 - DISMANTLING AND DEMOLISHING Page 2 of 3


Page 68 of 132

Code Description Unit Rate (Rs.)

1514 Dismantling sheet roofing including ridges, hips, valleys, gutters etc.
stacking the serviceable materials and disposal of unserviceable materials
within 100 metres lead.
(b) A.C. sheet roofing sqm. 64.7

1515 Dismantling Tiled roofing with battens boarding etc. including stacking of
serviceable materials and disposal of unserviceable materials within 100
metres lead.
(a) Single Mangalore Rani Ganj, Allahabad or similar tiling. sqm. 79.3
(b) Double Allahabad tiling or Mangalore roofing tiles with ceiling tiles sqm. 118.8
or slate roofing.
(c) Country tiles (Single layer) sqm. 79.3
(d) Country tiles (Double layer) sqm. 118.8

1516 Demolition of thatch roofing including mats, bamboo jaffari, capping to sqm. 38.2
ridges, hips, etc. including stacking of serviceable materials and disposal
of unserviceable materials within 100 metres lead.
1517 Dismantling cement asbestos celotex/ hard board in ceiling or partition sqm. 28.9
walls including stacking of serviceable materials and disposal of
unserviceable materials within 100metres lead.(frame work such as joists,
beams to be measured and paid for separately)
1518 Dismantling ballies in posts, purlins or rafters including stacking the RM 6.9
materials within 100 metres lead.
1519 Dismantling doors, windows and clear storey windows, ventilators etc.
(wood or steel) shutters including choukhats, architraves, hold fasts and
other attachments etc. complete and stacking them within 100 metre lead.
(a) Not exceeding 3 sqm. in area Each 115.4
(b) Exceeding 3 sqm. in area Each 154.9

1520 Taking out doors, windows and clear storey windows, shutters (steel or
wood) including stacking within 100 metre lead.
(a) Not exceeding 3 sqm. in area Each 58.7
(b) Exceeding 3 sqm. in area Each 78.3

1521 Dismantling barbed wire or flexible wire rope in fencing including making sqm. 8.7
rolls and stacking within 100 metres lead (frame work to be measured and
paid for separately)
1522 Dismantling and stacking within 100 metres lead fencing posts or struts
(wood, steel or R.C.C.) including all earth work and dismantling of
concrete etc. in the base and making good the disturbed ground.
(a) Wooden posts of any size RM 246.3
(b) Steel sections of any size RM 249.7
(c) R.C.C. posts of any size RM 319.3

1523 Dismantling ballies or wooden posts at the points of projection above the Each 15.2
concrete or ground including taking out iron steps, bolts nuts etc. if any,
and stacking the same within 100 metres lead.

RES - NIC MPSU 15 - DISMANTLING AND DEMOLISHING Page 3 of 3


Page 69 of 132
16 - MISCELLANEOUS - I
NOTE:
16.1 The rates include -
(a) All leads and lifts of matrerials unless otherwise specified.
(b) The cost of materials in which water includes.
(c) The cost of mixing motor, curing and scaffolding etc
16.2 Rates, where not specified otherwise, are based on fact that cement mortar 1:6, 1:5
and 1:3 is being used for masonry, plaster and pointing respectively, without any extra
cost.
16.3 R.C.C. items includes false work, cost of reinforcement and finishing also.
Code Description Unit Rate (Rs.)

1601 Providing plinth protection, 50mm thick in cement concrete 1:3:6 sqm. 117.4
(1cement, 3coars sand, 6graded stone aggregate 20mm nominal size)
including finishing the surface of concrete smooth.
1602 Providing plinth protection, with bricks of class 35 in cement mortar 1:6 sqm. 354.8
(1cement, 6fine sand) including pointing top surface of bricks with cement
mortar 1:2 (1cement, 2sand)
1603 Brick edging (brick laid on edge) to plinth protection with bricks of class RM 34.4
35 including grouting with cement mortar 1:4 (1cement, 4fine sand)
1604 Providing and fixing aluminium step 'L' shape to stairs.

(a) Aluminium L shape of size 38 mm X 12 mm X 3 mm (thick) RM 137.8


(b) Aluminium L shape of size 57 mm X 16 mm X 3 mm (thick) RM 171.2

1605 Labour only for item no.1604 RM 389.9

1606 Providing and fixing 25mm bore galvanised M.S. tube (medium grade) RM 437.5
outlet in cement mortar 1:3 (1cement, 3fine sand) including cutting and
making good the wall.
1607 Providing and fixing 40mm nominal bore galvanised M.S. tube (medium
grade) outlet in cement mortar 1:3 (1cement, 3fine sand)
(a) Using emulsion with Aldrin, Heptachlor or Chlordane cum 746.1
(b) Using emulsion with Dieldrin cum 763.7

1608 Anti-termite treatment including breaking the termite mounds, making


holes with crow bars and pouring chemical emulsion at the rate of 4Litres
per cubic metre of mound.
(a) Using emulsion with Aldrin, Heptachlor or Chlordane sqm. 733.3
(b) Using emulsion with Dieldrin sqm. 755.5

1609 Treating the bottom and sides of excavation at the rate of 5 litres per sqm
of surface area for antitermite treatment.
(a) Using emulsion with Aldrin, Heptac sqm. 1081.3
(b) Using emulsion with Dieldrin sqm. 2128.5

1610 Treating the back fill in contact with foundation at the rate of 15 litres per
sqm of vertical surface. (area of the sub-structure)in contact with back fill
to be measured) for anti-termite treatment.
(a) Using emulsion with Aldrin, Heptachlor or Chlordane sqm. 733.3
(b) Using emulsion with Dieldrin sqm. 755.5

1611 Treating the top surface of filled earth at the rate of 5 litres per sqm of
surface area for antitermite treatment.

RES - NIC MPSU 16 - MISCELLANEOUS - I Page 1 of 2


Page 70 of 132

Code Description Unit Rate (Rs.)

(a) Using emulsion with Aldrin, Heptachlor or Chlordane sqm. 2245.4


(b) Using emulsion with Dieldrin sqm. 2312.0

1612 Treating the soil along external perimetre of building at the rate of 1 5 sqm. 493.0
litres per sqm of the perimetre wall for antitermite treatment.
1613 Broken glass coping as specified on top of walls in cement mortar 1:3 sqm. 80.7

1614 Labour only for item no.1613 RM 71.0

1615 Construction of Black Board surface on wall in C.M. 1:3 (Projecting 6 sqm. 194.2
mmm. out of plastered surface of walls including painting with black
board paint and finishing to the true shape and size with 40 mm wide
alround boarder of cement mortar 1:3

RES - NIC MPSU 16 - MISCELLANEOUS - I Page 2 of 2


Page 71 of 132
17 - SURVEY AND INVESTIGATION
NOTES:
17.1 Survey shall be carried out departmentally. The progress of departmental labour
employed on NMR shall be checked with the rates given in this chapter.
17.2 Length of the survey will be measured along the lines on which particular type of
survey is to be done. For example, for chain and compass survey, it would be the length
along which the chaining and compassing is to be done. For levelling, it would be the total
length of the lines along which levels are to be taken.
17.3 (a) The rates are based on the following average daily progress that can be normally
achieved under average conditions by one survey party
………………………………………………………………………………………………
Items Other work Canals/Roads
………………………………………………………………………………………………
Chain and compass survey 2 km 3.0 km
Levelling ( above 15 m interval ) 2 km 2.5.km
………………………………………………………………………………………………
(b) The labour strength of one survey party for chain and compass survey considered in (a)
above is 12 mazdoors (3 for ranging, 1 for preparing pegs, 1pagman, 2chainman,
1compassman, 2axeman for removing obstacles, 1waterman and 1watchman for watch and
ward of camp ). For levlleing (above 15m interval) the labour strength considered is 8
mazdoor ( 2chain and tapeman, 1staffman, 1instrumentman, 1waterman, 1umbrellaman,
and 2axeman for removing obstacles )
(c) In very difficult terrain and special circumstances where the progress may be less,
special sanction for the rate should be obtained from the superintending Engineer and the
provision for the same in estimate.
17.4 The following Indian Standards may be referred to
IS No. Title.
273-1973 Picks and beaters (second revision)
1492-1970 Metric chains (first revision)
1759-1980 Powrahs (first revision)
1779-1961 4- Metre levelling staff, folding type (reaffirmed 1977)
1842-1961 Surveying chain pins (arrows) (reaffirmed 1977)
1955-1961 Prismatic compass, liquid (reaffirmed 1977)
1957-1961 Prismatic compass, non liquid (reaffirmed 1977)
2288-1963 Ranging rods (reaffirmed 1977)
2976-1964 Optical theodolite (reaffirmed 1977)
2988-1965 Vernier theodolite (reaffirmed 1977)
4080-1967 Vertical staff gauges
4590-1967 Engineer's level
Code Description Unit Rate (Rs.)

1701 Boring holes with auger in all types of soil upto 5m depth below G.L.
including collection samples.
(a) 200 mm dia RM 391.8
(b) 250mm dia RM 512.4
(c) 300 mm dia RM 602.8

1702 Chain and compass survey.

RES - NIC MPSU 17 - SURVEY AND INVESTIGATION Page 1 of 2


Page 72 of 132

Code Description Unit Rate (Rs.)

(a) Headworks/Other Works km. 1808.4


(b) Canals/Roads km. 1205.6

1703 Chain and Theodolite survey.

(a) Headworks/Other Works km. 1808.4


(b) Canals/Roads km. 1205.6

1704 Theodolite work involving fixing of stones at every tenth chain, tangent, km. 3616.8
apex and vertex points final alignment.
1705 Fly levelling for fixing temporary bench marks.

(a) Upto 15 m interval km. 1808.4


(b) Above 15 m interval km. 904.2

1706 Levelling - Headwork.

(a) Below 5 m interval km. 3014.0


(b) 5 to 10 m interval km. 2411.2
(c) More then 10 but seat upto 15 m interval km. 1808.4
(d) Above 15 m interval km. 964.5

1707 Double levelling for transfer of bench marks.

(a) Upto15 m interval km. 7233.6


(b) Above 15 m interval km. 3616.8

1708 Construction of temporary approach road of 2.5m average width for


survey vehicle, involving cutting of field boundaries, providing ramps at
depressions and touching the uneven surface and jungle clearance.
(a) In non-hilly terrain km. 15070.0
(b) Hilly terrain km. 30140.0

1709 Catchment area survey.

(a) Chain and compass survey along ridge line km. 1808.4
(b) Levelling along ridge line and cross sections km. 3616.8

RES - NIC MPSU 17 - SURVEY AND INVESTIGATION Page 2 of 2


Page 73 of 132
18 - COLLECTION OF MATERIALS
NOTES:
18.1. The rates are for collection of materials at Quarry.
18.2. The payment for collection will be made for delivery of materials at specified sites.
18.3. The rates include-
(a) All lead and lift involved for collection purpose at quarry.
(b) Screening to remove dust etc. if quarried at the site of collection.
(c) Removal of unsuitable material or weathered stuff.
18.4. The rates do not include -
(a) Royalty charges.
(b) Stacking or boxing.
18.5. For collection of materials on N.M.R. the rates do not include -
(a) opening of quarry and removal of over burden.
(b) making approach road in quarry area.
If the cost of items (a) & (b) above added together to likely to exceed or exceed by more
than 5% of the cost of collection of the specific material, prior written premission of S.E.
will be required.
18.6.Measurements -
(a) Metal and kankar will be stacked in boxes of 1.5 mt. X 1.5mt. X 0.5mt size and will be
measured as 1 cum, Moorum and sand will also be measured with same box size and will
be measured 0.90 cum. Boulders will be stacked in regular stacks measuring 2.5m X 5m X
0.50m to be measured as 5 cum.
(b) The following deduction will be made from stack measurements.
(1) Metal, Kankar, gravel, shingle, stone chips and quarry spalls……………...11 %
(2) Moorum, sand, boulders, masonry stone, pitching stone and rubble……….20 %
(3) Puddle earth……………………………………………….……..……...25 %
(c) For other works if (b) and (c) cannot be followed the materials may be stacked in
stacks with length and breadth in multiple of 1 meter.
18.7. (a) Boulders mean stones of any type which have been weathered and rounded off
due to action of sun, wind and rain and which occur in natural condition, either on the
surface of earth or buried below the surface.
(b) Quarried stones mean stones of suitable sizes which have been broken from much
bigger boulders, stones or rock extracted from quarries. The criteria for this more than 50
% of the surface of each stone should be broken surface.
18.8. Blasting- Blasting rate is payable for item 0204 & 0205 for collection from quarries
of massive hard rock or compact lime stone, hard sand stones or similar formations for the
extraction of which blasting is actually done.
18.9 MOST 2004 refferd to, in this chapter meanse "Specifications for road and bridge
works (third revision)" publised by Indian Road Congress on behalf of Ministry of Surface
Transport (Road Wing) New Delhi 2004.
18.10 Size of metal should confirm to the grading as per table below :-
Single or Sized Coarse aggregate of nominal size
………………………………………………………………………………………………
……
Nominal Size of Passing Through Retained on square
aggregate in mm mesh size in mm mesh size in mm
………………………………………………………………………………………………
……
100 110 80.0
Page 74 of 132
080 090 60.0
060 075 40.0
040 050 25.0
025 040 20.0
020 025 12.0
012 020 06.0
010 012 06.0
006 010 03.5
------------------------------------------------------------------------------------------------
Code Description Unit Rate (Rs.)

1801 Collection of puddle earth including stacking at quarry cum 186.3

1802 Collection of approved soil having CBR not less than 5, including cum 186.3
stacking at quarry.
1803 Collection of approved soil having CBR not less then 12, including cum 217.3
stacking at quarry.
1804 Collection of hard metal other then black trap basalt and granite for road
works (without blasting) including stacking as per MOST 1995, clause
400.2.5
(a) Grading - 1 (Size ranging from 90 mm to 45 mm) cum 496.7
(b) Grading - 2 (Size ranging from 63 mm to 45 mm) cum 605.4
(c) Grading - 3 (Size ranging from 53 mm to 22.4 mm) cum 683.0

1805 Collection of hard metal other then black trap basalt and granite for
building work (without blasting) .
(a) 40 mm nominal size cum 683.0

1806 Deduct from item 1804 and 1805 above for metal breaking with Govt. cum 217.3
boulders and excavated rock.
1807 Collection of boulders at source (maximum size 0.014cum) without cum 170.7
quarrying i.e. picked up boulders.
1808 Collection of quarried stone or rubble.

(a) Maximum size 0.014 cum cum 248.4


(b) Size 0.014 cum to 0.06 cum 310.4

1809 Collection of stone chips. quarry spalls or rubble (maximum size


0.004cum) Black trap, basalt or granite.
(a) Other then black trap Basalt or granite cum 232.8
(b) Black trap Basalt or granite cum 260.8

1810 Collection of size stone for coursed rubble masonry rectangular in shape
(maximum size 0.014cum to 0.06cum) including 20%headers.
(a) Other then black trap Basalt or granite cum 585.2
(b) Black trap Basalt or granite cum 643.8

1811 Collection of rubble masonry (size 0.014cum to 0.06cum) other then black cum 771.5
trap, basalt or granite.

RES - NIC MPSU 18 - COLLECTION OF MATERIALS Page 2 of 3


Page 75 of 132

Code Description Unit Rate (Rs.)

1812 Collection of face stones for dam masonry hammer dressed on face, with
one line chisel dressed 75mm depth from face on bed, top and sides and
hammer dressed below 75mm depth of the stone up to rear face beyond
this depth of 75mm the stones may taper, but minimum length specified
having at least half the area of the face, comprising of hammer dressed
size for coursed rubble masonry rectangular in shape (maximum size
0.014cum to 0.06cum) including 20%headers. Other then black trap,
basalt or granite.
(a) Stretcher- size 55 x 35 x 30 cm Each 192.4
(b) Header- size 60 to 45 x 30 x 30 cm Each 200.7
(c) Bond stone-size 70 to 60 x 30 x 30 cm Each 225.8

1813 Collection of pitching stones size 20 to 25cm and not less then 0.021cum
(without dressing)
(a) Other then black trap Basalt or granite cum 336.9
(b) Black trap Basalt or granite cum 370.6

1814 Collection of pitching stones size 28 to 32cm and not less then 0.024cum
(without dressing)
(a) Other then black trap Basalt or granite cum 274.8
(b) Black trap Basalt or granite cum 302.3

1815 Extra rate for blasting for item 1804 and 1805

(a) Other then black trap Basalt or granite cum 54.1


(b) Black trap, basalt or granite. cum 135.2

1816 Extra rate for black trap basalt, granite. for items 1804, 1805, 1808, 1811 cum 10% of
& 1812 respective item
1817 Stacking and boxing.

(a) Moorum or sand cum 31.0


(b) Metal, single or gravel cum 52.8

1818 Stacking without boxing.

(a) Puddle earth, moorum, sand or kankar cum 21.7


(b) Metal, single, stone chips or quarry spalls cum 27.9
(c) Masonry stones, pitching stones or boulders cum 55.9

1819 Screening-

(a) Metal, shingle or gravel cum 77.6


(b) Sand cum 55.9

1820 Washing sand, metal, shingle or gravel (Payable on prior written cum 155.2
permission of S.E.)
1821 Collection of boulders or rubble from excavated materials. cum 99.3

1822 Collection of through/ bond stones. cum 1150.2

1823 Collection of sand including screening, washing, stacking and all leads cum 232.8
and lifts up to the loading point.

RES - NIC MPSU 18 - COLLECTION OF MATERIALS Page 3 of 3


Page 76 of 132
19 - TRANSPORTATION OF MATERIALS
NOTES:
19.1 The rate include loading and unloading but exclude stacking unless specifically
mentioned in the item. The stacking charges will be payable as per items and of chapter
"Collection of Materials " and item 1909 and 1910 of this chapter.
19.2. For fractions of lead, next higher lead shall be payable.
19.3. Rate for transportation beyond 200m apply for all modes of transportation by road ie.
cart, truck or any other means.
19.4. For finished items, payments for materials will be made as per quantities shown in
appendix - I.
19.5. For finished items the payment will be made for delivery of materials at specified
sites.
19.6. Measurements :-
(a) The following deductions will be made from stack measurement -
(i) Metal Kankar, gravel, shingle, stone chips and quarry spalls………………...11 %
(ii) Moorum, sand boulders, masonry stones, pitching stones and rubble………..20 %
(iii) Puddle earth………………………………………………………….25 %
(b) Metal moorum and sand for use on road work will be boxed for measurements in boxes
measuring 1.5 m x 1.5 m x 0.50 m.
(c) Boulders for use on road work will be stacked in regular stacks measuring 2.5m x 5m x
0.50m .
(d) For other works if (b) and (c) cannot be followed the materials may be stacked in stacks
with length and breadth in multiples of 1 meter.
19.7. Rates for carting hume pipes are inclusive of transportation of collars also. The
transportation rate for pipe alone is only 92 % of the full rate and 8 % is the rate of
transportation of collars.
19.8 .Deleted
19.9 Rates of this chapter are not applicable for contract work.
Code Description Unit Rate (Rs.)

1901 Transportation charges of water for every additional 200m or part thereof,
beyond initial lead of 200m up to 2 Km. Lead for -
(a) Consolidation of Moorum /earth work (rate for 1Cum. of Moorum cum 3.0
/earth work)
(b) Puddle work (rate for 1Cum. of earth work) cum 4.2
(c) Construction of masonry or concrete(rate for 1Cum. of masonry or cum 16.6
concrete)
(d) Metal consolidation of W.B.M. Road(rate for 1Cum. of Metal) cum 6.6

1902 Transportation of metal -

(a) 0.5 Km. Lead cum 107.4


(b) 1.0 Km. Lead cum 115.2
(c) 1.5 Km. Lead cum 122.7
(d) 2.0 Km. Lead cum 129.9
(e) 2.5 Km. Lead cum 137.3
(f) 3.0 Km. Lead cum 144.4
(g) 3.5 Km. Lead cum 151.5

RES - NIC MPSU 19 - TRANSPORTATION OF MATERIALS Page 1 of 4


Page 77 of 132

Code Description Unit Rate (Rs.)

1902 Transportation of metal -

(h) 4.0 Km. Lead cum 158.4


(i) 4.5 Km. Lead cum 165.1
(j) 5.0 Km. Lead cum 171.7

1903 Add if Lead is more than 5.00Km

(a) For every 0.5 Kms. Lead beyond 5 Kms. and part there of upto 10 cum 5.3
Kms.
(b) For every 0.5 Kms. Lead beyond 10 Kms. and part there of upto 30 cum 4.0
Kms.
(c) For every 0.5 Kms. Lead beyond 30 Kms. and part there of upto 50 cum 3.6
Kms.
(d) For every 0.5 Kms. Lead beyond 50 Kms. and part there of upto 100 cum 3.3
Kms.
(e) For every 0.5 Kms. Lead beyond 100 Kms. cum 2.6

1904 Transportation rates for different construction materials.

01. Masonry stone. cum 140% of metal


transportation
rate.
02. Bricks, kanker, stone chips shingle & excavated materials in cum Same as per
disintegrated rock & soft rock. metal
transportation.
03. Boulders, Laterite, rubble pitching stones and excavated hard rock. cum 115% of metal
transportation
rate.
04. Moorum, sand, earth, surkhi, fly ash, cement and mortars. cum 90% of metal
transportation
rate.
05. Lime (fat), Hydraulic or any other. cum 70% of metal
transportation
rate.
06. Flag stone 20 to 40 mm thick sqm. 4% of metal
transportation
rate.
07. Flag stone 40 to 50 mm thick sqm. 6% of metal
transportation
rate.
08. Stone slabs or stone lintels of thickness above 50 mm. sqm. 140% of metal
transportation
rate.
09. Col, fuel wood, iron work, steel G.I sheets paints, oils, pipes and MT 90% of metal
machinery etc transportation
rate.
10. 120 to 150 mm dia ballies. RM 1.5% of metal
transportation
rate.
11. 100 to 119 mm dia ballies. RM 0.8% of metal
transportation
rate.
12. 75 to 99 mm dia ballies. RM 0.3% of metal
transportation
rate.

RES - NIC MPSU 19 - TRANSPORTATION OF MATERIALS Page 2 of 4


Page 78 of 132

Code Description Unit Rate (Rs.)

1904 Transportation rates for different construction materials.

13. Swan timber. cum 67% of metal


transportation
rate.
14. Mangalore, Burn & Co. cement sand pattern tiles, including ridges sqm. 4% of metal
hipes mosaic and terrazzo tiles. transportation
rate.
15. Single Allahabad or country wheel including ridges and hips sqm. 6% of metal
transportation
rate.
16. Double Allahabad or Double wheel including ridges and hips. sqm. 12% of metal
transportation
rate.
17. Tar, Maxphalt, Asphalt and Bitumen. etc. MT 104.5% of
metal
transportation
rate.
18. A.C. big six or trafford sheets sqm. 1.2% of metal
transportation
rate.
19. A.C. ridges and hips for item 1818 RM 0.8% of metal
transportation
rate.
20. Bamboos 100 No. RM 4% of metal
transportation
rate.
21. Hume pipes (NP-2) 80 mm to 150 mm dia. RM 3% of metal
transportation
rate.
22. Hume pipes (NP-2) 250 mm to 300 mm dia. RM 7% of metal
transportation
rate.
23. Hume pipes (NP-2) 350 mm to 450 mm dia. RM 14% of metal
transportation
rate.
24. Hume pipes (NP-2) 500 mm to 600 mm dia. RM 19% of metal
transportation
rate.
25. Hume pipes (NP-2) 700 mm to 750 mm dia. RM 33% of metal
transportation
rate.
26. Hume pipes (NP-2) 800 mm to 900 mm dia. RM 46% of metal
transportation
rate.
27. Hume pipes (NP-2) 1000 mm to 1200 mm dia. RM 93% of metal
transportation
rate.
28. Hume pipes (NP-2) Above 1200 mm dia. RM 140% of metal
transportation
rate.
29. Hume pipes (NP-3) 350 mm to 450 mm dia. RM 20% of metal
transportation
rate.
30. Hume pipes (NP-3) 500 mm to 600 mm dia. RM 30% of metal
transportation
rate.

RES - NIC MPSU 19 - TRANSPORTATION OF MATERIALS Page 3 of 4


Page 79 of 132

Code Description Unit Rate (Rs.)

1904 Transportation rates for different construction materials.

31. Hume pipes (NP-3) 700 mm to 750 mm dia. RM 50% of metal


transportation
rate.
32. Hume pipes (NP-3) 800 mm to 900 mm dia. RM 70% of metal
transportation
rate.
33. Hume pipes (NP-3) 1000 mm to 1200 mm dia. RM 140% of metal
transportation
rate.
1905 Loading & stacking of cement from the

(a) Railway godown in to truck, dumper MT 117.9


(b) Deptt. godown or site to truck, dumper etc. MT 104.8

1906 Unloading & stacking of cement from the

(a) Railway wagon & stacking on Railway platform MT 117.9


(b) Truck, trolly or dumper etc. & stacking in store MT 91.7

1907 Loading of steel from the

(a) Railway godown or store yard in to truck, dumper MT 123.3


(b) Deptt. godown or site to truck, dumper etc. MT 89.1

1908 Unloading of steel from the

(a) Railway wagon & stacking on Railway platform MT 116.5


(b) Truck, trolly or dumper etc. & stacking in store MT 102.8

1909 Stacking of cement bags Bag 2.5

1910 Stacking of steel bars in store MT 48.0

1911 Loading of metal in truck, dumper etc. cum 60.3

1912 Unloading of metal in truck, dumper etc. cum 30.1

1913 Loading of materials other then metal, cement and steel in truck, dumper, Rate of item
trolly etc. 1911 multiplied
by % given in
item 1904
1914 Unloading of materials other then metal, cement and steel in truck, Rate of item
dumper, trolly etc. 1912 multiplied
by % given in
item 1904
1915 Extra rate for loading in truck, dumper etc for NP2 pipes (dia above 50% of the
400mm)NP3 pipes and heavy pieces of other materials (each piece of amount arrived
more then 300kg) in item 1913
1916 Extra rate for unloading from truck, dumper, etc. for NP2 pipes (dia above 50% of the
400mm)NP3 pipes and heavy pieces of other materilas(each piece of more amount arrived
then 300kg) in item 1914

RES - NIC MPSU 19 - TRANSPORTATION OF MATERIALS Page 4 of 4


Page 80 of 132
20 - ROAD WORK
NOTES:
20.1 No seperate payment for lead and lift shall be permissible unless otherwise specified.
20.2 MOST 2004 refferd to, in this chapter meanse "Specifications for road and bridge
works (fifth revision)" publised by Indian Road Congress on behalf of Ministry of Surface
Transport (Road Wing) New Delhi 2004.
20.3 Open season means the period between 1st November to 15th June.
20.4 Gradation of aggregates for premix carpet
i. Coarse aggreates - 13.2 mm size; passing 22.4 mm sieve and retained on 11.2 mm sieve.
ii. Coarse aggregates - 11.2 mm size; passing 13.2 mm sieve and retained on 5.6 mm sieve.

20.5 Gradation of aggregates for liquid/ Premix seal-coat


coarse aggregates of 6.7 mm size; passing 9.5 mm sieve and retained on 2.36 mm sieve.
20.6 The following Indian Road Congress publications may be referred to -
IRC NO Title
14-1977 Recommended practice for 2cm thick bitumen and tar carpets (third revision).
17-1977 Standard specifications and code of practice for water bound macadam (second
revision)
IS No. Title
73-1961 Specifications for Paving bitumen (Revised) (with amendment No.1)
215-1961 Specifications for Road tar (Revised)
217-1961 Specifications for cut back bitumen (Revised)
454-1961 Specifications for cut back bitumen-Digboi type (Revised)
3117-1965 Specifications for bitumen, emulsion for Roads (anionic type)
20.7 :- ISI marked reinforced cement concrete hume pipes must be used in construction of
roads. In cases were ISI marked hume pipes are not available, Project Manager/ Executive
Engineer may allow use of hume pipes conforming to IS specifications duly tested by DGS
& D. The testing certificate of DGS & D will be kept on record before making payment of
item of such hume pipes. In such case the rates of relevant item shall be paid 5% less than
the rates prescribed in chapter 20.

Code Description Unit Rate (Rs.)

2001 Preparation of sub grade by excavating earth work to the 15cm average
depth, dressing to camber including making good the undulations etc. and
disposal of surplus earth with lead upto 50metres and upto 1.5metre.
(a) Loose or soft soil sqm. 14.5
(b) Dence or hard soil sqm. 18.5

2002 Deleted ......

2003 Deleted ---- ----

2004 Labour only for boulder soling hand packed excluding consolidation. cum 192.0

2005 Labour only for spreading, hand packing, and levelling to gradient and cum 131.8
required camber as per MOST 2004 clause 404.3.3 of metal, grade-1 As
per MOST 2004 clause 400.2.5 including dressing.
2006 Labour only for spreading, hand packing, and levelling to gradient and cum 100.7
required camber as per MOST 2004 clause 404.3.3 of metal grading-2 &
3 as per MOST 2004 clause 400.2.5 including dressing.
2007 Labour only for moorum, screening or binding material as per MOST cum 42.7
2004 clause 400.2.6 spreading on boulder or WBM coat as per MOST
2004 clause 404.2.7
Page 81 of 132
Code Description Unit Rate (Rs.)

2008 Rolling & Compaction of granular sub-base of well graded material, cum 55.2
spreading in uniform layers with tractor mounted grader on prepared
surface, mixing by mix in place, sprinkling of water till OMC, and
compacting with smooth wheel rollers of 80 to 100 kN static weight to
achieve the desired density, complete as per Technical Specification
Clause 401 of Specification for Rural Roads.i/c all leads of water etc.
complete.
2009 Deleted ---- ----

2010 Rolling and consolidating water bound mecadam coat with any size of
metal of any thickness upto 100mm thickness(including rolling screening
or binding materials) including watering & filling in depressions which
occur during the process with power roller exceeding 8 tonne as per
MOST 2004 clause 404.3.4 to 404.3.8
(a) Including hire and running expenses of roller sqm. 8.1
(b) Excluding hire and running expenses of roller sqm. 1.1

2011 Picking old surface for consolidation. sqm. 8.2

2012 Metal patch repair of WBM surface including picking of old surface and cum 1064.9
spreading metal and screening material, consolidation or compaction by
hand ramming etc. complete
2013 Providing laying and compacting of 40mm thick metal renual coat in wet cum 715.4
season including picking old road surface, spreading of clean and crushed
aggregate grading - 3, screenings and korebandi and rolling with power
roller exceeding 8 tonne as per MOST 2004 clause 404.
2014 Providing laying and compacting of W.B.M. sub base/ base course
including preparation and compaction of sub base and spreading of clean
and crushed aggregate to proper grade and camber including application
of screenings for interlocking, sprinkling of water and rolling with power
roller as per clause 404 (excluding inverted choke and scarifying of
existing bitumenous surfaces) for-
(a) Grading No. 1 Material, (90 to 45mm size) with moorum as cum 837.4
screening
(b) Grading No. 2 Material, (63 to 45mm size) with moorum as cum 826.2
screening
(c) Grading No. 3 Material, (53 to 22.4mm size) with moorum as cum 856.4
screening
2015 Preparing surface by brushing with wire brushes for remaining caked mud
etc. sweeping with brooms and finally fanning the cleaned surface with
gunny bags to remove all loose dirt etc.
(a) Water Bound Mecadam surface sqm. 26.7
(b) Black top surfaces sqm. 16.0

2016 Heating binder upto required temperature including fuel for heating MT 3622.7

2017 Heating binder upto required temperature excluding fuel for heating MT 2249.5

2018 Labour only for applying evenly a priming/ tack coat with the bituminous sqm. 6.5
primer(bitumen 80/100) @ 10kg./10 sqm on WBM surface.
2019 Labour only for screening and spreading aggregates for black top roads cum 331.4

2020 Rolling & compacting of B.T. surface for Surface dressing coat or pre mix
carpet or seal coat with power roller exceeding 8 tonne.
(a) Including hire and running expenses of roller sqm. 4.1
(b) Excluding hire and running expenses of roller sqm. 1.0

2021 Providing and applying evenly a priming coat with the bituminous sqm. 40.8
emulsion @ 9kg./10 sqm
Page 82 of 132
Code Description Unit Rate (Rs.)

2022 Providing tack coat as per MOST clause 503 over existing primed surface
with bituminous emulsion.
(a) Normal B.T. surface @ 2.50 kg./10 Sqm. area. sqm. 12.9
(b) Granular surface (Primed)/ Cement concrete surface @ 3.00 kg./10 sqm. 16.5
Sqm. area.
(c) Granular surface (Not Primed) @ 10 kg./10 Sqm. area. sqm. 45.3

2023 Providing single coat surface dressing with paving bitumen using 18kg. of sqm. 98.2
bitumen VG - 10 (80/100 penetration) per 10 sqm with 0.15cum of stone
chipping 13.2mm nominal size per 10 sqm of road surface for second coat
and rolling complete with power roller exceeding 8 tonne.
2024 Surface dressing two coats with paving bitumen using 18kg. of bitumen sqm. 157.3
VG - 10 (80/100 penetration) per 10sqm with 0.15cum of stone chipping
13.2mm nominal size per 10sqm for 1st coat and 11kg. of bitumen VG -
10 (80/100 penetration) per 10sqm with 0.10cum of stone chipping
11.2mm nominal size per 10sqm of road surface for second coat and
rolling complete with power roller exceeding 8 tonne.
2025 2cm consolidated thick single coat premix carpet surfacing with 0.27cum sqm. 97.3
of stone chippings (13.2mm Size 0.18cum and 11.2mm size 0.09cum)
mixed with 14.6kg. of binder [bitumen VG - 10 (80/100 penetration)] per
10sqm of road surface and rolling complete with power roller exceeding 8
tonne.
2026 2.5cm consolidated thick single coat premix carpet surfacing with sqm. 118.4
0.30cum of stone chippings 11.2mm Size 0.18cum mixed with 19.2kg
bitumen VG - 10 (80/100 penetration) per 10sqm of road surface and
rolling complete with power roller exceeding 8 tonne.
2027 Liquid seal coat(I.R.C. type A) with 0.09cum of stone chippings 6.7mm sqm. 58.4
size and down graded 9.8kg. of bitumen VG - 10 (80/100 penetration) per
10 sqm of road surface.
2028 Pre-mixed seal coat (type B) with 0.06cum of stone chippings, passing sqm. 43.3
2.36mm size and retained on 180 micron IS sieve and 6.8kg. of bitumen
VG - 10 (80/100 penetration) per 10 sqm of road surface.
2029 Providing and filling in foundation trenches and at the back of abutments,
wing walls etc. and below pipe bed in layers not exceeding 15cm thick
including watering and compacting including all lead and lifts.
(a) Good local sand free from earth. cum 598.2
(b) Selected granular material in filling. cum 584.6

2030 Precast Cement Concrete M15 kerb including fixing at site. RM 163.6

2031 Painting two coats after filling the surface with synthetic enamel paint in sqm. 63.4
all shades on new plastered concrete surface.
2032 Deleted ----- -----

2033 Providing and laying reinforced cement concrete pipes N.P.2 for culverts
including pointing ends, and fixing collar with cement martar 1:2
complete.
(a) 300 mm dia RM 468.9
(b) 450mm dia RM 846.2
(c) 600mm dia RM 971.6
(d) delete ------ -----

2034 Laying reinforced cement concrete pipes N.P.2 for culverts including
pointing ends, and fixing collar with cement martar 1:2 complete.
(a) 300mm dia RM 44.4
(b) 450mm dia RM 66.3
Page 83 of 132
Code Description Unit Rate (Rs.)

2034 Laying reinforced cement concrete pipes N.P.2 for culverts including
pointing ends, and fixing collar with cement martar 1:2 complete.
(c) 600mm dia RM 88.2
(d) delete ---- ----

2035 Providing and laying reinforced cement concrete pipes N.P.3 for culverts
including pointing ends, and fixing collar with cement martar 1:2
complete.
(a) 900 mm dia. RM 3490.3
(b) 1000 mm dia. RM 3853.2
(c) 1200 mm dia. RM 4775.4
(d) 600 mm dia. RM 1512.8

2036 Laying reinforced cement concrete pipes N.P.3 for culverts including
pointing ends, and fixing collar with cement martar 1:2 complete.
(a) 900 mm dia. RM 247.9
(b) 1000 mm dia. RM 264.7
(c) 1200 mm dia. RM 292.4
(d) 600 mm dia. RM 201.6

2037 Deleted ---- -----

2038 Cement Concrete Pavement


Construction of un-reinforced, dowel jointed at expansion and contraction
joint only, plain cement concrete pavement, thickness as per design, over a
prepared sub base, with 43 grade cement or any other type as per clause
1501-2-2 M30 (Grade), coarse and fine aggregates conforming to IS:383,
maximum size of coarse aggregate not exceeding 25 mm, dowel bars 25
mm dia and 500 mm long @ 25 cm c/c or as per design, mixed in a
concrete mixer of not less than 0.2 cum capacity and appropriate weigh
batcher using approved mix design, laid in approved fixed side formwork
(steel channel), laying and fixing of 125 micron thick polythene film,
wedges, steel plates including levelling the formwork as per drawing),
spreading the concrete with shovels, rakes, compacted using needle,
screed, and plate vibrators and finished in continuous operation including
provision of contraction and expansion, construction joints, applying
debonding strips, primer, sealant, dowel bars, near approaches to
bridge/culvert and construction joints, admixtures as approved, curing of
concrete slabs for 14-days,using curing compound (where specified) and
water finishing to lines and grade as per drawing and Technical
Specification Clause 1501.
(a) M 30 Cement Concrete for rigid pavement cum 3466.8
(b) Providing and fixing of 500mm long 25 mm dia bars in expansion cum 55.5
joints complete.
(c) Providing and laying of polythelen sheet of 125micron thick cum 4.8
(d) Providing laying making filling and sealing of expansion and cum 17.1
contraction joints complete.
Page 84 of 132
Code Description Unit Rate (Rs.)

2039 Construction of granular sub-base (GSB) by naturally occurred material or


river born material or by crushed metal or mixture of two or more, to bring
the material in appropriate grading mentioned in table 400.1, (I, II or III)
of specifications for rural roads(MORD), having minimum soacked CBR
value of 20, Liquid Limit and Plasticity Index should not be more then 25
and 6 respectively, mixing by mix in place method by rotavator, spreading
in 4% camber and required gradient with tractor mounted grader or
labourers on prepared surface, watering at OMC and compacting with 80
to 100 kN static weight rollers to achieve desired density minimum 100%
of the MDD as per IS:2720 (Part-7). Complete work as per specifications
for rural roads (MORD) clause 401, i/c all leads and lifts of materials etc.
complete.
(a) For minimun soacked CBR Value of 20 cum 470.0
(b) For minimum soacked CBR value of 30 cum 524.5

2040 Loosening, Levelling and Compacting original ground, supporting cum 10.0
embankment to facilitate placement of first layer of embankment, scarified
to a depth of 150 mm, spreading in 4% camber and required gradient with
tractor mounted grader or labourers, watering at OMC and compacted by
80 to 100 kN static weight rollers to achieve desired density minimum
97% as given in tables 300.1 and 300.2 for embankment construction as
per specifications for rural roads (MORD) clause 301.4.1 (This work shall
be executed with prior written permission of SE)
2041 Compaction of embankment with approved materials as per clause 301.4 cum 16.9
& 301.5 of specifications for rural roads(MORD), already spreaded at site,
obtained from roadway cutting, excavated from drains, foundation of other
structures or from borrow pit, making 4% camber and required Grade by
tractor mounted grader or labourers, watering at OMC and compacted by
80 to 100 kN static weight rollers to achieve desired density minimum
97% as per table 300.1 and 300.2 of (MORD) - i/c required leads and lifts
of materials etc. complete.
2042 Compaction of soil for construction of subgrade & earthen shoulders with cum 18.9
approved material, already spreaded at site, obtained from roadway
cutting, drains, foundation of other structures or barrow pits, i/c making
4% camber and required grade by tractor mounted grader or labourers,
watering at OMC and compacted by 80 to 100 kN static weight rollers to
achieve desired density minimum 100% of the MDD as per IS:2720
(Part-7). Complet compaction work as per specifications for rural roads
(MORD) clause 303, i/c required leads and lifts of materials etc. complete.
2043 Compaction of soil for construction of subgrade & earthen shoulders with cum 24.7
approved transported material collected and stacked at site, i/c spreading,
making 4% camber and required gradient by tractor mounted grader or
labourers, watering at OMC and compacted by 80 to 100 kN static weight
rollers to achieve desired density minimum 100% of the MDD as per
IS:2720 (Part-7). Complete compaction work as per specifications for
rural roads (MORD) clause 303, i/c required leads and lifts of materials
etc. complete.
2044 Construction of hard shoulder as per clause 407 of specifications for rural cum 370.2
roads (MORD), with soil having CBR value not less than 12, inclusive of
all leads and lifts, providing 4-5% camber by tractor mounted grader or
labourers, watering at OMC and compacted by 80 to 100 kN static weight
rollers to achieve desired density minimum 100% of the MDD as per
IS:2720 (Part-7), i/c all leads and lifts of materials etc. complete.
2045 Compaction of hard shoulder collected at site, i/c making 4-5% camber by cum 35.9
tractor mounted grader or labourers, watering at OMC and compacting
with 80 to 100 kN static weight rollers to achieve desired density
minimum 100% of the MDD as per IS:2720 (Part-7), as per clause 407 of
specifications for rural roads(MORD), i/c required leads and lifts of
materials etc. complete.
Page 85 of 132
Code Description Unit Rate (Rs.)

2046 Deleted .....

2047 Deleted ....

2048 Construction of Gravel Base Course as per clause 402 of "Ministry of


Rural Development, Specifications for Rural Roads-August, 2004" by an
appropriate combination of natural gravel, river borne material and
crushed metal in required proportions confirming to Grading requirements
specified in clause 2.2.2.2 or clause 2.2.2.3 (Table 2.3, Material having
Nominal Maximum Size 80 mm or 40 mm or 20 mm) of IRC:SP:77-2008,
having Liquid Limit and Plasticity Index less than 25 and 10 respectively,
including all leads and lifts of material etc. complete. The mixing shall be
by Mix-in-Place method over prepared surface, spreading in uniform
layers with tractor mounted grader or manually, watering at OMC and
compaction by smooth wheeled/vibratory roller of 80 to 100 kN static
weight to achieve 100% of MDD as per IS:2720 (Part-7).
(a) Above item having material strength not less than 80% CBR cum 631.3
(b) Above item having material strength not less than 30%CBR cum 576.9

2049 "Construction of Gravel Surface Course as per clause 402 of "Ministry of cum 508.6
Rural Development, Specifications for Rural Roads-August, 2004" by an
appropriate combination of natural gravel, river borne material and
crushed metal in required proportions confirming to Grading requirements
specified in clause 2.2.2.2 or clause 2.2.2.3 (Table 2.3, Material having
Nominal Maximum Size 20 mm or 10 mm) of IRC:SP:77-2008, having
Liquid Limit less than 40 and Plasticity Index 6-15 and strength of
material not less than 20% CBR, including all leads and lifts of material
etc. complete. The mixing shall be by Mix-in-Place method over prepared
surface, spreading in uniform layers with tractor mounted grader or
manually, watering at OMC and compaction by smooth wheeled/vibratory
roller of 80 to 100 kN static weight to achieve 100% of MDD as per
IS:2720 (Part-7)".
2050 Excavation, Carting i/c Removal of Soil with Disposal upto 1000 m cum 42.0

Excavation of embankment, sub-grade and drain consisting of excavation,


removal and satisfactory disposal of all excavated materials including
hauling to sides of embankment and subgrade construction as also the
disposal of materials in specified manner and the trimming and finishing
of the road to the specified dimensions i/c all lifts, lead upto 1000 meters
including dewatering, shaping and excavation in marsh and complete
disposal of all muck as per clause 302. for all types of soil i/c moorum
gravel etc. as directed by the Engineer-in-charge
2051 Construction of Embankment, subgrade & earthen shoulders with Material cum 156.0
Obtained from Borrow Pits. Construction of embankment,
subgrade & earthen shoulders with approved material (Select soil having
CBR 7) obtained from borrow pits i/c all leads and lift and removal of
top soil if any, including cost of land as a source of material, transporting
to site, spreading, graded by motor grader to required slope and
compacting using vibratory rollers of 80 to 100 kN static weight to meet
requirement of Tables 300.1 and 300.2 including all leads, etc. as per
Technical Specification Clauses 301.4, 301.5, and 303.
Note : If Select Soil (CBR 7) is available within a lead of 250 meters ,
rate of Item 2052 will be payable.
2052 Construction of embankment, subgrade & earthen shoulders with cum 144.2
approved material obtained from borrow pits i/c all leads and lift and
removal of top soil if any, including cost of land as a source of material,
transporting to site, spreading, graded by motor grader to required slope
and compacting using vibratory rollers of 80 to 100 kN static weight to
meet requirement of Tables 300.1 and 300.2 including all leads, as per
Technical Specification Clauses 301.4, 301.5, and 303.
Page 86 of 132
Code Description Unit Rate (Rs.)

2053 Deduct from item 2051 or 2052 if static roller is used in place of vibratory cum 6.6
rollers.
2054 Deduct from item 2051 or 2052 if motor grader is not used. cum 6.9

2055 Deduct from item 2051 or 2052 if Tractor Mount Grader, more than 65 cum 4.7
HP (6 wheel - 4 wheel drive) is used in place of motor grader.
Page 87 of 132
21 - WATER SUPPLY & FITTINGS
NOTES:
21.1 All leads and lifts of all matrerials unless otherwise specified.
21.2 The materials used shall conform to the relevant I.S.S.
21.3 The rates for pipeline, include laying of pipeline below ground or fixed to the walls,
steel tubings with steel socket joints, together with all tube fittings (such as bends, elbows,
tees, reducers, plugs, unions, sleeve pieces, etc.) and fixing complete with
holder-bat-clamps or wall-hooks (when pipe is fixed in chases), wooden plugs, making
holes in the walls for crossing the pipe and repairing the same with cement mortar 1:3 to
the original condition, excavation of trenches of required depth and width in all type of
soils, refilling the trenches, with surface properly dressed and rammed.
21.4 The rates for laying and fixing include all labour and materials, tools and plants other
than tubes and fittings.
Measurements :
(i) All work shall be measured net as fixed to the nearest 0.01 m unless otherwise stated.
(ii) The pipe line shall be measured net as fixed, including the length of all fittings
(measured along the centre line) and no allowance shall be made for wastage etc.
21.5 The following Indian Standards may be referred to :
I.S. No. Title
554-1975 Dimensions for pipe threads where pressure joints are required on the
threads (second revision) (with amendment No.1)
778-1980 Copper alloy gate, globe and check valves for water supply purposes
(third revision)
781-1977 Cast copper alloy screw-down bid taps and stop valves for water services
(second revision) (with amendment no.1)
782-1978 Caulking lead (third revision)
1068-196 Electroplated coating of nickle and chromium on iron and steel (first
revision) (with amendment No.1&2)
1172-197 Code of basis requirements for water supply, drainage and sanitation
(second revision)
1239 Mild steel tubes, tubular and other wrought steel fittings.
1239-(Pt.I.)1979 Part I-Mild steel tubes (fourth revision) (with amendment No.1)
1239 (Pt.ii.)1969 Part II-Mild steel tubulars and other wrought steel pipe fittings (second
revision)
1711-1970 Self-closing taps (first revision) (with amendment 1 & 2) (reaffirmed
1979)
1795-1974 Pillar taps for water supply purposes (first revision) (with amendment 1 to
4)
2065-1972 Code of practice for water supply in buildings (first revision)
2629-1966 Recommended practice for hot dip galvanising of iron and steel.
2692-1978 Ferrules for water services (first revision)
4346-1978 Washers for water taps for cold water services (reaffirmed 1979)
4736-1968 Hot-dip zinc coating on steel tubes.
9763-1981 Plastic bib taps and stop valves (rising spindle for cold water services)
Code Description Unit Rate (Rs.)

2101 Providing and fixing to wall ceiling and floor galvanised mild steel tubes
(medium grade) of the following nominal bore, tube fittings and clamps
including walling making good the wall, ceiling and floor

RES - NIC MPSU 21 - WATER SUPPLY & FITTINGS Page 1 of 8


Page 88 of 132

Code Description Unit Rate (Rs.)

(a) 15 mm dia. RM 129.8


(b) 20 mm Diameter. RM 153.2
(c) 25 mm dia. RM 186.7
(d) 32 mm dia. RM 232.3
(e) 40 mm dia. RM 265.0
(f) 50 mm dia. RM 338.2

2102 Labour only for item no.2101

(a) 15 mm dia. RM 47.2


(b) 20 mm dia. RM 50.4
(c) 25 mm dia. RM 53.6
(d) 32 mm dia. RM 63.6
(e) 40 mm dia. RM 80.5
(f) 50 mm dia. RM 97.6

2103 Fixing G.I pipe line, with all materials except pipe, fitting and clamps but
including making good the walls and floors etc. complete (for item 2101)
(a) 15 mm dia. RM 49.6
(b) 20 mm dia. RM 52.9
(c) 25 mm dia. RM 56.3
(d) 32 mm dia. RM 66.8
(e) 40 mm dia. RM 84.5
(f) 50 mm dia. RM 102.5

2104 Providing and laying in trenches galvanised mild steel tubes (medium
grade) of the following nominal bore, tube fittings (earth work in trenches
to be measured and paid for separately)
(a) 15 mm dia. RM 80.0
(b) 20 mm dia. RM 97.8
(c) 25 mm dia. RM 129.3
(d) 32 mm dia. RM 160.4
(e) 40 mm dia. RM 178.2
(f) 50 mm dia. RM 227.1
(g) 65 mm dia. RM 308.9
(h) 80 mm dia. RM 402.3
(i) 100 mm dia. RM 584.6

2105 Labour only for item no.2104

(a) 15 mm to 20 mm dia. RM 8.1


(b) 25 mm to 32 mm dia. RM 12.4
(c) 40 mm to 50 mm dia. RM 16.4
(d) 65 mm to 100 mm dia. RM 30.1

RES - NIC MPSU 21 - WATER SUPPLY & FITTINGS Page 2 of 8


Page 89 of 132

Code Description Unit Rate (Rs.)

2106 Laying G.I pipe line, with all materials except pipe, fitting and clamps but
including excavation of trenches and refilling etc. complete (for item
2104)
(a) 15 mm to 20 mm dia. RM 8.9
(b) 25 mm to 32 mm dia. RM 13.7
(c) 40 mm to 50 mm dia. RM 18.1
(d) 65 mm to 100 mm dia. RM 33.1

2107 Providing and fixing to wall, ceiling and floor 6.00kgf/sqcm working
pressure polyethylene pipes of the following outside diameter low density
complete with special flange compression type fitting wall clips etc.
including making good the wall ceiling and floor.
(a) 20 mm dia. RM 54.3
(b) 25 mm dia. RM 56.4
(c) 32 mm dia. RM 62.4
(d) 40 mm dia. RM 76.0
(e) 50 mm dia. RM 86.1

2108 Providing and fixing to wall, ceiling and floor 6.00kgf/sqcm working
pressure polyethylene pipes of the following outside diameter high density
complete with special flange compression type fitting wall clips etc.
including making good the wall ceiling and floor.
(a) 32 mm dia. RM 72.9
(b) 40 mm dia. RM 84.4
(c) 50 mm dia. RM 95.1

2109 Labour only for item no. 2107 & 2108

(a) 20 mm to 32 mm dia. RM 37.2


(b) 40 mm to 50 mm dia. RM 39.8

2110 Providing and laying in trenches 6.0kgf/sqcm working pressure


polyethylene pipes of the following outside diameter low density complete
with special flange compression type fitting (earth work in trenches is to
be measured and paid for separately)
(a) 20 mm dia. RM 21.6
(b) 25 mm dia. RM 23.5
(c) 32 mm dia. RM 29.0
(d) 40 mm dia. RM 41.0
(e) 50 mm dia. RM 50.2

2111 Providing and laying in trenches 6.0kgf/sqcm working pressure


polyethylene pipes of the following outside diameter high density
complete with special flange compression type fitting (earth work in
trenches is to be measured and paid for separately)
(a) 32 mm dia. RM 38.5
(b) 40 mm dia. RM 48.6
(c) 50 mm dia. RM 58.3

RES - NIC MPSU 21 - WATER SUPPLY & FITTINGS Page 3 of 8


Page 90 of 132

Code Description Unit Rate (Rs.)

2112 Labour only for item no.2110 & 2111

(a) 20 mm to 32 mm dia. RM 6.1


(b) 40 mm to 50 mm dia. RM 8.1

2113 Making connection of galvanised mild steel distribution branch with


galvanised mild steel main by providing and fixing tee including cutting
the pipes complete.
(a) 25 mm to 40 mm nominal bore. Each 286.5
(b) 50 mm to 80 mm nominal bore. Each 384.1

2114 Labour only for item no.2113

(a) 25 mm to 40 mm nominal bore. Each 232.4


(b) 50 mm to 80 mm nominal bore. Each 317.0

2115 Fixing water meter and stop cock in galvanised mild steel tube of the Each 239.4
following nominal bore including necessary fittings such as mild steel
galvanised jamnut, socket etc cutting and threading the tube and making
long screws complete (water meter, jam nut and stop cock to be measured
and paid for separately)
2116 Providing and fixing 600mm X 450mm bevelled edge mirror of superior nos. 559.8
glass mounted on 6mm thick A.C. sheet or plywood sheet and fixed to
wooden plugs with C.P. brass screws and washers.
2117 Labour only for item no.2116 nos. 213.0

2118 Providing and fixing 600mm X 120mm glass shelf with C.P. brass nos. 386.2
brackets and guard rail complete, fixed to wooden plugs with C.P. brass
screws.
2119 Labour only for item no.2118 nos. 161.4

2120 Providing and fixing C.P. brass towel rail complete with C.P. brass
brackets fixed to wooden plugs with C.P. brass screws.
(a) 750 x 20mm. size. Each 483.9
(b) 600 x 20mm. size. Each 422.1

2121 Labour only for item no.2120 nos. 109.7

2122 Providing and fixing liquid soap Glass container with C.P. brass lid and nos. 270.6
brackets fixed to wooden plugs with C.P. brass screws.
2123 Labour only for item no.2122 nos. 77.5

2124 Providing and fixing Chromium Plated brass dish with C.P. brass brackets nos. 261.8
fixed to wooden plugs with C.P. brass screws.
2125 Labour only for item no.2124 nos. 77.5

2126 Providing and fixing ferule of the following nominal bore including
boring.
(a) 15mm nominal bore. Each 113.2
(b) 20mm nominal bore. Each 157.7
(c) 25mm nominal bore. Each 167.1

2127 Labour only for item no.2126

RES - NIC MPSU 21 - WATER SUPPLY & FITTINGS Page 4 of 8


Page 91 of 132

Code Description Unit Rate (Rs.)

(a) 15mm nominal bore. Each40% of item no.


2126(a)
(b) 20mm nominal bore. Each30% of item no.
2126(b)
(c) 25mm nominal bore. Each20% of item no.
2126(c )
2128 Providing and Fixing Brass Screw Down Bib Taps polished bright of the
following nominal bore.
(a) 15mm dia. Each 144.6
(b) 20mm dia. Each 189.2
(c) 25mm dia. Each 222.7

2129 Providing and Fixing capstan head with porcelain disc marked hot or cold,
bib taps of the following nominal bore.
(a) 15mm dia. Each 173.6
(b) 20mm dia. Each 203.4
(c) 25mm dia. Each 241.3

2130 Providing and Fixing 15mm dia Chromium plated Bib Taps of the Each 241.1
following nominal bore.
2131 Providing and fixing 15mm dia pillar taps, capstan head screw down, high Each 289.3
pressure lettered 'Hot' or 'Cold' with long screws, shanks and bank nuts of
the following nominal bore.
2132 Labour only for item no.2128, 2129, 2130 & 2131

(a) 15mm dia. Each 6% of item no.


2128(a) 2129(a)
2130(a) 2131(a)
(b) 20mm dia. Each 4% of item no.
2128(b)
2129(b)
2130(b)
2131(b)
(c) 25mm dia. Each 2% of item no.
2128(c) 2129(c)
2130(c) 2131(c)
2133 Providing and Fixing Brass Screw Down stop Tap of the following
nominal bore.
(a) 15 mm nominal size Each 163.9
(b) 20 mm nominal size Each 198.7
(c) 25 mm nominal size Each 296.9
(d) 32 mm nominal size Each 413.5
(e) 40 mm nominal size Each 689.1
(f) 50 mm nominal size Each 918.8

2134 Labour only for item no.2133

(a) 15mm dia. Each 6% of item no.


2134(a)
(b) 20mm dia. Each 4% of item no.
2134(b)
(c) 25mm dia. Each 2% of item no.
2134(c)

RES - NIC MPSU 21 - WATER SUPPLY & FITTINGS Page 5 of 8


Page 92 of 132

Code Description Unit Rate (Rs.)

2134 Labour only for item no.2133

(d) 32mm to 50mm dia. Each 1% of item no.


2134(d) to (f)
2135 Providing and Fixing Brass full-way valve of the following nominal bore
with wheel..
(a) 15mm nominal bore Each 241.1
(b) 20mm nominal bore Each 324.8
(c) 25mm nominal bore Each 473.1
(d) 32mm nominal bore Each 618.4
(e) 40mm nominal bore Each 768.4
(f) 50mm nominal bore Each 918.7
(g) 65mm nominal bore Each 1391.9
(h) 80mm nominal bore Each 1948.7

2136 Labour only for item no.2135

(a) 15mm nominal bore. Each 6% of item no.


2135(a)
(b) 20mm nominal bore. Each 5% of item no.
2135(b)
(c) 25mm nominal bore. Each 4% of item no.
2135(c)
(d) 32mm to 40mm nominal bore. Each 3% of item no.
2135(d)(e)
(e) 50mm to 80mm nominal bore. Each 2% of item no.
2135(f)(g)(h)
2137 Providing and fixing gun metal check or non-return valve, class-I, of the
following nominal bore.
(a) 25 mm nominal bore Each 406.6
(b) 32mm nominal bore Each 511.1
(c) 40mm nominal bore Each 640.0
(d) 50mm nominal bore Each 777.7
(e) 65 mm nominal bore Each 927.9
(f) 80 mm nominal bore Each 1286.4

2138 Labour only for item no.2137

(a) 25mm nominal bore. Each 9% of item no.


2137(a)
(b) 32mm nominal bore. Each 7% of item no.
2137(b)
(c) 40mm nominal bore. Each 5% of item no.
2137(c)
(d) 50mm nominal bore. Each 3% of item no.
2137(d)
(e) 65mm nominal bore. Each 2% of item no.
2137(e)
(f) 80mm nominal bore. Each 1% of item no.
2137(f)

RES - NIC MPSU 21 - WATER SUPPLY & FITTINGS Page 6 of 8


Page 93 of 132

Code Description Unit Rate (Rs.)

2139 Providing and fixing C.P. brass shower rose with 15mm or 20mm inlet.

(a) 100 mm dia. Each 90.5


(b) 150 mm dia. Each 123.5

2140 Labour only for item no.2139

(a) 100 mm dia. Each. 12 % of item


no. 2139(a)
(b) 150 mm dia. Each. 10 % of item
no. 2139(b)
2141 Providing and fixing in position best Indian make G.I. Elbows in G.I. Pipe
including cutting and threading the pipe and making long screws etc.
complete (New work)
(a) 15 mm dia. Each 24.9
(b) 20 mm dia. Each 26.7
(c) 25 mm dia. Each 32.9
(d) 32 mm dia. Each 52.8
(e) 40 mm dia. Each 65.3
(f) 50 mm dia. Each 83.3

2142 Labour only for item 2141

(a) Up to 25 mm dia. Each 11.4


(b) Up to 50 mm dia. Each 18.6

2143 Providing and fixing in position best Indian make G.I. Tees (equal) in G.I.
Pipe including cutting and threading the pipe and making long screws etc.
complete (New work)
(a) 15 mm dia. Each 33.0
(b) 20 mm dia. Each 40.2
(c) 25 mm dia. Each 47.3
(d) 32 mm dia. Each 76.2
(e) 40 mm dia. Each 85.1
(f) 50 mm dia. Each 112.1

2144 Labour only for item 2143

(a) Up to 25 mm dia. Each 15.0


(b) Up to 50 mm dia. Each 22.3

2145 Providing and fixing in position best Indian make G.I. Bend in G.I. Pipe
including cutting and threading the pipe and making long screws etc.
complete (New work)
(a) 15 mm dia Each 28.2
(b) 20 mm dia. Each 37.2
(c) 25 mm dia. Each 48.9
(d) 32 mm dia. Each 74.1
(e) 40 mm dia. Each 92.1

RES - NIC MPSU 21 - WATER SUPPLY & FITTINGS Page 7 of 8


Page 94 of 132

Code Description Unit Rate (Rs.)

2145 Providing and fixing in position best Indian make G.I. Bend in G.I. Pipe
including cutting and threading the pipe and making long screws etc.
complete (New work)
(f) 50 mm dia. Each 110.0

2146 Labour only for item 2145

(a) Up to 25 mm dia. Each 12.9


(b) Up to 50 mm dia. Each 20.2

2147 Providing and fixing in position best Indian make G.I. Union in G.I. Pipe
including cutting and threading the pipe and making long screws etc.
complete (New work)
(a) 15 mm dia. Each 55.5
(b) 20 mm dia. Each 67.2
(c) 25 mm dia. Each 80.7
(d) 32 mm dia. Each 101.4
(e) 40 mm dia. Each 119.3
(f) 50 mm dia. Each 155.3

2148 Labour only for item no.2147

(a) Up to 25 mm dia. Each 22.3


(b) Up to 50 mm dia. Each 29.5

2149 Providing and placing on terrace (at all floor levels) polyethylene water ltr. 5.3
storage tank ISI : 12701 marked with cover and suitable locking
arrangment and making necessary holes for inlet, outlet and overflow
pipes but without fittings and the base support for tank.
2150 Labour only for item 2149 ltr. 7% of item no.
2149

RES - NIC MPSU 21 - WATER SUPPLY & FITTINGS Page 8 of 8


Page 95 of 132
22 - SEWAGE, DRAINAGE AND SANITARY FITTINGS
NOTES :
22.1 The rates include -
(a) All leads and lifts of matrerials unless otherwise specified.
(b) The cost of materials in which water includes.
(c) The cost of mixing motor, curing and scaffolding etc
22.2 The materials used shall conform to relevant ISS.
22.3 The rates include, wherever necessary, conveyance and delivery, handling, loading,
un-loading, storing, fabrication, hoisting, all necessary labour for finishing to required
shape and size, fitting and fixing in position, cutting and waste and other incidental
operation.
22.4 In case of septic tanks, items pertaining excavation, concrete and masonry shall be
paid as per relevant chapters.
22.5 The materials shall confirm to relevant ISS.
Measurements
(i) All work shall be measured net as fixed to the nearest 0.01 m unless otherwise
specified .
(ii) The pipe line shall be measured net as fixed inclusive of all joints (measured along the
centre line) and no allowance shall be made for wastage etc.
(iii) Length of fittings shall not be included with measured length of the pipe line.
22.6 The following Indian Standards may be referred to :-
I.S.No. Title
651-1980 Salt- glazed stone ware pipes and fittings (fourth revision)
1626 Asbestos cement building pipes, pipe fitting ,gutters, and gutter
fitting and roofing fittings
1626(pt.I)1980 Pipes and pipe fittings (first revision)
1626(pt.II)1980 Gutters and gutter fitting (first revision)
1726 Cast iron manhole covers and frames.
1726(pt.I)1974 General requirements (second revision)
1726(pt.II)1974 Specific requirements for H.D. circular type (second revision)
1726(pt.IV)1974 Specific requirements for L.D. circular type (second revision) ( with
amendment No.1)
1726(pt.V)1974 Specific requirements for L.D. rectangular type (second revision)
1726(pt.VI/sce.1)1974 Specific requirements for L.D. rectangular type Sec.1 single seal
(second revision)
1726(pt.VI/sce.2)1974 Specific requirements for L.D. rectangular type Sec.2 Double seal
(second revision)
1726(pt.VII/sce.1)1974 Specific requirements for L.D. square type Sec.1 single seal (first
revision)
2470 Code of practice for design and construction of septic tanks
2470(pt.I)1968 Small installations (first revision)
2470(pt.I)1968 Large installations(first revision)
2527-1963 Code of practice for fixing rain-water gutters and down pipes for
roof drainage
4127-1967 Code of practice for laying of glazed stoneware pipes
5329-1969 Code of practice for sanitary pipe work above ground for buildings
(with amendment no.1)
5455-1969 Cast iron steps for manholes
5961-1970 Cast iron gratings for purpose
Page 96 of 132
9872-1981 Precast concrete septic tanks
771(pt.II)1979 Glazed fire-clay sanitary appliances, Pt.II Specific requirements of
Kitchen and laboratory sinks (second-revision)
772-1973 General requirements for enamelled cast iron sanitary appliances
(second revision) (with amendment no. 1)
774-1971 Flushing cisterns for water-closets and urinals (valve less syphonic
type) (third revision) (with amendment no. 1 to 5)
775-1970 Cast iron brackets and supports for wash basins and sinks (second
revision)
2064-1973 Code of practice for selection, installation and maintenance of
sanitary appliances (first revision)
2326-1970 Automatic flushing cisterns for urinals (first revision)
2548-1980 Plastic water closet seats and covers (third revision)
2556 Vitreous sanitary appliances (vitreous china)
2556(pt.I)1974 General requirements (second revision) (with amendment no.1)
2556(pt.II)1981 Specific requirements of wash down water-closets (third revision)
2556(pt.III)1981 Specific requirements of squatting pans (third revision)
2556(pt.IV)1972 Specific requirements of wash basins (second revision)
2556(pt.V)1979 Specific requirements of laboratory sinks (second revision)
2556(pt.VI/Sec.1)1979 Specific requirements of urinals Section 1. Bowl type (third
revision)
2556(pt.VI/Sec.2)1974 Specific requirements of urinals Section 2. Half stall urinals
(second revision)
2556(pt.VI/Sec.3)1974 Specific requirements of urinals Section 3. Squatting plates
2556(pt.VI/Sec.4)1974 Specific requirements of urinals Section 4. Partition slabs (second
revision) (with amendment no.1)
2556(pt.VI/Sec.5)1974 Specific requirements of urinals Section 5. Waste fittings (second
revision)
2556(pt.VI/Sec.6)1974 Specific requirements of urinals Section 6. Water spreaders for
half stall urinals (second revision)
2556(pt.VII)1973 Specific requirements of half round channel (second revision)
2556(pt.VIII)1973 Specific requirements of syphonic wash-down water closets
(second revision) (with amendment No.1)
2556(pt.IX)1979 Specific requirements of bidets (third revison)
2556(pt.X)1979 Specific requirements of foot rests (second revison)
2556(pt.XII)1973 Specific requirements of floor traps
2556(pt.XIII)1973 Specific requirements of for integrated squatting pans (with
amendment no.1)
2556(pt.XV)1974 Specific requirements of universal water closets (with amendment
no1 and 2)
2963-1979 Copper alloy waste-fittings for wash basins and sinks (First revision)
3311-1979 Waste plug and its accessories for sinks and wash basins (First
revision)
5961-1970 Cast iron gratings for drainage purpose (Reaffirmed 1979)
7231-1974 Plastic flushing cisterns (valveless syphonic type) for water closets
and urinals
8718-1978 Vitreous enamelled steel kitchen sinks.
8727-1978 Vitreous enamelled steel wah basins.
9440-1979 Vitreous sanitary appliances (vitreous china) methods of sampling
of.
Page 97 of 132
9758-1981 Flush valves and fittings for water closets and urinals.

Code Description Unit Rate (Rs.)

2201 Providing and fixing water closet squatting pan (Indian type W.G. pan)
size 580mm (earth work bed concrete, foot rests and trap to be measured
and paid for separately)
(a) Vitreous China Long pattern- white colour Each 784.9
(b) Vitreous China Orissa pattern - white colour Each 917.4
(c) Vitreous China Orissa pattern- standard colour Each 961.5
(d) Glazed earthenware Long pattern Each 917.4
(e) Glazed earthenware Orissa pattern Each 802.5

2202 Providing and fixing wash down water closet squatting pan (European
type W.C. pan) with integral 'P' or 'S' trap including jointing the trap with
soil pipe in cement mortar 1:1 (1cement, 1fine sand) - (seat and cover to
be measured and paid for separately)
(a) Vitreous China -Pattern 1 in white colour Each 1204.4
(b) Vitreous China -Pattern 1 in standard colour. Each 1270.7
(c) Vitreous China -Pattern 2 in white colour. Each 1182.3
(d) Vitreous China -Pattern 2 in standard colour. Each 1429.6
(e) Glazed Earthenware-Pattern 1 Each 1094.0
(f) Glazed Earthenware-Pattern 2 Each 1138.2
(g) Glazed Earthenware-Pattern 3 Each 1182.3

2203 Labour only for item no.2201 & 2202 Each 352.2

2204 Providing and fixing 100mm size 'P' or 'S' trap for water closet squatting
pan including jointing the trap with pan and soil pipe in cement mortar 1:1
(1cement, 1fine sand)
(a) Vitreous china Each 338.7
(b) Glazed earthenware. Each 321.5
(c) Sand Cast Iron. Each 369.0

2205 Labour only for item no.2204 Each 174.4

2206 Providing and fixing in cement mortar 1:3 (1cement, 3 coarse sand) a pair Pair 161.4
of white vitreous China 250mm X 130mm X 30mm foot rest for long
pattern squatting pan water closet.
2207 Labour only for item no.2206 Pair 24.0

2208 Fixing 12.5 litres low and high level flushing cistern with a pair of C.I. Or
M.S. brackets complete with fittings each as lead valve loss syphon.
15mm nominal size brass ball valve with polythene float, C.P. brass
handle, unions and couplings for connection with inlet, outlet and over
flow pipes, 40mm dia porcelain enamelled flush bend including cutting
holes in walls and making good the same and connecting the flush bend
with cistern and closet (overflow pipe to be measured and paid for
separately)
(a) Vitreous China white colour low level Each 1390.4
(b) Vitreous China white colour high level Each 1652.0

RES - NIC MPSU 22 - SEWAGE, DRAINAGE AND SANITARY FITTINGS Page 3 of 7


Page 98 of 132

Code Description Unit Rate (Rs.)

2209 Providing and fixing in position with clamps, etc. 32mm nominal internal RM 149.3
diameter galvanised steel tube flush pipe for high level flushing cistern
including connecting the flush pipe with cistern and closet and making
good the walls and floors.
2210 Labour only for item no.2209 RM 62.0

2211 Providing and fixing bowl pattern urinal including connecting the urinal
with waste pipe by means of white lead mixed with chopped hemp (waste
pipe to measured and paid for separately)
(a) Vitreous China flat back type of size 430 mm x 260 x mm x 350 mm Each 676.0
white colour
(b) Vitreous China flat back type of size 430 mm x 260 x mm x 350 mm Each 676.0
in Standard colours except misty-lilac.
(c) Vitreous China angle back type of size 340 mm x 430 mm x 265 mm Each 639.6
in white colour
(d) Vitreous China angle back type of size 340 mm x 430 mm x 265 mm Each 594.1
in standard colour except Misty-Lilac
(e) Glazed Earthenware flat back type of size 430 mm x 260 x mm x Each 588.2
350 mm
(f) Glazed Earthenware angle back type of size 340 mm x 430 mm x Each 503.1
265 mm
2212 Labour only for item no.2211 Each 275.7

2213 Providing and fixing squatting plate pattern urinal of size 600mm X
350mm with integral longitudinal flush pipe.
(a) Vitreous china Each 1175.7
(b) Glazed Earthenware. Each 1088.4

2214 Labour only for item no.2213 Each 704.4

2215 Providing and fixing automatic flushing cistern with a pair of C.I. Or M.S.
brackets, complete with fittings including C.I. Syphonic apparatus
mosquito proof lid, C.P. brass unions and couplings for connection with
inlet, outlet and over flow pipes including cutting holes and making good
the same overflow pipe to be measured and paid for separately
(a) Glazed Earthenware of the following nominal size 5 litres Each 1469.0
(b) Glazed Earthenware of the following nominal size10 litters Each 1730.7
(c) Glazed Earthenware of the following nominal size 15 litters Each 1817.9
(d) Cast Iron of the following nominal size 5 litre Each 1207.4
(e) Cast Iron of the following nominal size10litre Each 1381.8
(f) Cast Iron of the following nominal size 15 litre Each 1469.0

2216 Labour only for item no.2215 Each 503.0

2217 Providing and fixing C.P. brass flush pipe/spreaders for urinal of the
following nominal box with fittings such as unions, clamps etc (all in D.P.
brass) including cutting holes and making good the same.
(a) 15 mm RM 130.4
(b) 20 mm RM 151.7
(c) 25 mm RM 168.0
(d) 32 mm RM 185.1

RES - NIC MPSU 22 - SEWAGE, DRAINAGE AND SANITARY FITTINGS Page 4 of 7


Page 99 of 132

Code Description Unit Rate (Rs.)

2218 Labour only for item no.2217

(a) 15 mm RM 47.2
(b) 20 mm RM 50.4
(c) 25 mm RM 53.6
(d) 32 mm RM 63.6

2219 Providing and fixing wash basin with single hole for pillar tap with C.I. or
M.S. brackets painted white including cutting holes and making good the
same but excluding fitting.
(a) Vitreous China flat back wash basin 630 mm x 450 mm size in white Each 1804.2
colour
(b) Vitreous China flat back wash basin 630 mm x 450 mm size in Each 1892.6
standard colour except Misty-Lilac
(c) Vitreous China Flat back wash basin 550 mm x400 mm size in white Each 1406.8
colour
(d) Vitreous China Flat back wash basin 550 mm x 400 mm size in Each 1450.9
standard colour except Misty-Lilac
(e) Vitreous China Angle back wash basin 600 mm x 480 mm white Each 1450.9
colour
(f) Vitreous China Angle back wash basin 400 mm x 400 mm white Each 1141.8
colour
(g) Glazed earthenware flat back wash basin 630 mm x 450 mm size Each 1627.6
white colour
(h) Glazed earthenware flat back wash basin 550 mm x 400 mm size Each 1186.0
white colour
(i) Glazed earthenware Angle back wash basin 600 x 480 mm size white Each 1362.6
colour
(j) Glazed earthenware Angle back wash basin 400 x 400 mm size white Each 1097.6
colour
2220 Labour only for item no.2219 Each 467.9

2221 Providing and fixing kitchen sink with C.I. or M.S. brackets painted white
including cutting holes and making good the same but excluding fitting.
(a) White glazed fire clay sink 600 mm x 450 mm x 150 mm Each 1798.0
(b) White glazed fire clay sink 600 mm x 450 mm x 250 mm Each 1886.3
(c) White glazed fire clay sink 750 mm x 450 mm x250 mm Each 2062.9
(d) Terrazzo finish sink 600 mm x 450 mm x 150 mm Each 1665.5
(e) Terrazzo finish sink 600 mm x 450 mm x 250 mm Each 1842.1
(f) Terrazzo finish sink 750 mm x 450 mm x 250 mm Each 1886.3
(g) Vitreous China sink 600 mm x 450 mm x 150 mm Each 1709.6
(h) Vitreous China sink 600 mm x 450 mm x 250 mm Each 1886.3
(i) Vitreous China sink 750 mm x 450 mm x 250 mm Each 1974.6

2222 Labour only for item no.2221 Each 390.4

2223 Providing and fixing laboratory sink with C.I. or M.S. brackets painted
white including cutting holes in walls and making good the same but
excluding fitting.
(a) Vitreous China 450 mm x 300 mm x 150 mm size Each 1179.7

RES - NIC MPSU 22 - SEWAGE, DRAINAGE AND SANITARY FITTINGS Page 5 of 7


Page 100 of 132

Code Description Unit Rate (Rs.)

2223 Providing and fixing laboratory sink with C.I. or M.S. brackets painted
white including cutting holes in walls and making good the same but
excluding fitting.
(b) Vitreous China 600 mm x 400 mm x 200 mm size Each 1533.0
(c) Glazed Earthenware 450 mm x 300 mm x 150 mm size Each 1356.3
(d) Glazed Earthenware 600 mm x 400 mm x 200 mm size Each 1533.0

2224 Labour only for item no.2223 Each 390.4

2225 Providing and fixing C.P. brass waste for wash basin or sink .

(a) 32 mm dia Each 127.3


(b) 40 mm dia Each 140.1

2226 Providing and fixing M.I. fisher union for wash basin or sink .

(a) 32 mm dia Each 70.7


(b) 40 mm dia Each 85.0

2227 Providing and fixing C.P. brass or M.I. Trap for wash basin and sink.

(a) 32 mm dia Each 86.8


(b) 40 mm dia Each 98.1

2228 Providing and fixing plastic seat and cover for wash down water closet
with C.P. brass hinges and rubber buffers.
(a) White plastic seat and cover Each 306.6
(b) Black plastic seat and cover Each 283.0

2229 Labour only for item no.2228 Each. 10 % of item


no. 2228
2230 Providing and fixing C.P. brass waste of following nominal bore and plug
for flazed ware sinks, basins etc. with long screwed shanks and fly nuts
and fixed to steel pipe including vulcanite plug, brass chain and stud.
(a) 32 mm dia Each 158.1
(b) 40 mm dia Each 197.6
(c) 50 mm dia Each 207.5

2231 Labour only for item no.2230 Each. 10 % of item


no. 2230
2232 Providing and fixing on Wall face Asbestos Cement building pipe of the
following nominal size including jointing with sun yarn soaked in bitumen
and cement mortar 1:2 (1cement, 2sand) complete .
(a) 50 mm dia. RM 112.4
(b) 80 mm dia. RM 128.6
(c) 100 mm dia. RM 159.8

2233 Labour only for item no.2232

(a) 50 mm dia. RM 61.9


(b) 80 mm dia. RM 74.8

RES - NIC MPSU 22 - SEWAGE, DRAINAGE AND SANITARY FITTINGS Page 6 of 7


Page 101 of 132

Code Description Unit Rate (Rs.)

2233 Labour only for item no.2232

(c) 100 mm dia. RM 94.5

2234 Providing and fixing asbestos cement fitting. Plain Bend of the following
nominal size including jointing with spun yarn soaked in bitumen and
cement mortar 1:2 complete.
(a) Plain bend.50 mm dia Each 98.7
(b) Plain bend.80 mm dia. Each 103.3
(c) Plain bend.100 mm dia. Each 107.8

2235 Labour only for item no.2234 Each 62.3

2236 Providing and fixing in position A.C. cowls of the following nominal size
including jointing with spun yarn soaked in bitumen and cement mortar
1:2 complete.
(a) Cone cap cowl 50 mm dia. Each 98.7
(b) Cone cap cowl 80 mm dia. Each 107.8
(c) Cone cap cowl 100 mm dia. Each 121.5
(d) Slotted vend cowl 50 mm dia. Each 112.4
(e) Slotted vend cowl 80 mm dia. Each 116.9
(f) Slotted vend cowl 100 mm dia. Each 116.9

2237 Labour only for item no.2236 Each 62.3

RES - NIC MPSU 22 - SEWAGE, DRAINAGE AND SANITARY FITTINGS Page 7 of 7


Page 102 of 132
23 - SPECIAL ITEMS OF EARTH/MASONRY DAM AND CANALS
NOTES :
23.1 The rates include all leads and lifts for all matrerials for all items unless otherwise
specified.
23.2 The item of stripping shall be payable for depths upto 15cm only. If greater depths
have tobe removed. Total depths are to be paid as per rates of general excavation of
earthwork.
23.3 In case of canal embankment the stripping of sea should normally be limied to 8cm
for canal discharge upto 3 cumec for embankment height above 1.5m and only furrowing
and ploughing be done for embankments of height less than 1.5m, and 15cm for canal
discharge more than 3cumec for embankment height above 0.6m and only furrowing and
ploughing be don for embankments of height less than 0.6m.
23.4. Stripping the seat of embankment should not be payable in the area covered by
benching the seat of embankment.
23.5. The rates for excavation of puddle trench includes the cost of cutting and subsequent
removal, if ordered, in steps required in deep trenches for the inspecting officers and the
working labourers to godown and come up. However it does not include filling up of these
steps eiher by puddle or by earth
23.6. The rates for puddle trench excavation, provided in this chapter, or not payble for
cut-offtrench excavation.
23.7. Regarding bailing out water frompuddle trench during excavation note of Chapter
"EXCAVATION AND EARTHWORK" is applicable.
23.8. For items of filter locally available shingle or gravel be used as a first preference.If it
is not available locally. Matal from excavaion of hard moorum with boulder or rock-cut be
used as a second alternative,provided it is certified by the Executive Engineer while
obtaining sanction to the estimate, that shingle or gravel is not available from nearby nalls
or rivers.
23.9. For use of metal for filter the extra rate for blasting shall not be payable.
23.10 The items against which multiplying numbers suffixed by "R" have been given in
the rates column, the payable rates on NMR shall be arrived at as per note of Chapter-"
Survey and Investigation"
23.11 In hand packed stone pitching of 45 cm thick in two layers, header stone of size 45 X
30 X 30 cm extending through both layers and spaced at about 1.5 m apart shall be used.
23.12 Measurement
(a) Dimensions shall be measured to nearest 0.01m. The eares shall be worked out to
the nearest 0.01 sq m. The cubical contents shall be worked out to nearest 0.01cum.
(b) No deduction for voids shall be made from the gross measurements of seepage
drain filling, boulder toe, pitching filter Bnanket etc.
23.13 No seperate payment for lead and lift shall be permissible unless otherwise specified.
23.14 The following Sandards and I.R.C. Specifications may be referred to :-
I.S. No./IRC No. Title
I.S. 8237-1976 Code of practics for protection of slope of reservoir embankments.
I.S. 9759-1981 Guide lines for dewatering during construction.
Code Description Unit Rate (Rs.)

2301 Deleted …. ….

2302 Deleted …. ….

RES - NIC MPSU 3 - SPECIAL ITEMS OF EARTH/MASONRY DAM AND CANAL Page 1 of 2
Page 103 of 132

Code Description Unit Rate (Rs.)

2303 Deleted …. ….

2304 Deleted

(a) Deleted ….. …..


(b) Deleted ….. …..
(c) Deleted ….. …..
(d) Deleted ….. …..

2305 Deleted …. ....

2306 Deleted …. ....

2307 Deleted …. ....

2308 FOR EARTHEN DAM - Providing fitter blanket, horizontally, including


laying, Spreading, packing etc. in layers of required thickness but
excluding excavation of foundation.
(a) Metal 80 mm nominal size cum 684.3
(b) Metal 60 mm nominal size cum 707.0
(c) Metal 40 mm nominal size cum 763.6
(d) Metal 20 mm nominal size cum 876.9
(e) Metal 10 mm nominal size cum 905.3

2309 Labour only for item 2308 cum 310.4

2310 FOR EARTHEN DAM - Construction of rock toe in earthen


embankments including laying and hand packing, dressing, wedging and
finishing over surface with.
(a) Boulders cum 632.6
(b) Quarried other then black trap, basalt or granite cum 697.2
(c) Black trap, basalt or granite cum 717.6

2311 Labour only for item 2310 cum 491.0

RES - NIC MPSU 3 - SPECIAL ITEMS OF EARTH/MASONRY DAM AND CANAL Page 2 of 2
Page 104 of 132
24 - WELL EXCAVATION
NOTES :
24.1 Rates include all lifts (after addition of item 2403 or item 2404 as the case may be)
and removal of excavated materials to a distance of 50 m beyond the well, unless
otherwise Specified.
24.2 Rates of rock cutting are subject to 40 % deduction for voids, if paid on stack
measurements.
24.3 Classification of strata shall be as per Note 3.2 of Chapter 03 “Excavation &
Earthwork”
24.4 For deepening of existing wells, the depth will be considered from platform level.
Code Description Unit Rate (Rs.)

2401 Earth work for well excavation including disposal of excavated soil lead
upto 50m and lift upto 1.5m, disposed soil to be levelled and neatly
dressed.
(a) Loose or soft soil cum 140.5
(b) Dense or hard soil cum 186.0
(c) Hard Moorum cum 241.7

2402 Earth work for well excavation including disposal or stacking of


excavated soil lead upto 50m lift upto 1.5m
(a) Disintegrated or soft rock (not requiring blasting) cum 501.1
(b) Hard rock requiring blasting. cum 672.3
(c) Hard rock requiring chiselling (where blasting is prohibited) cum 999.5

2403 Add in item No. 2401 for lift. (In well excavation)

(a) For every 0.50 m after 1.5 m initial depth upto 6.0 m cum 14.7
(b) For every 0.50 m after 6.0 m initial depth upto 10.5 m cum 19.4
(c) For every 0.50 m after 10.5 m initial depth upto 15.0 m cum 24.5

2404 Add in item No. 2402 for lift. (In well excavation)

(a) For every 0.50 m after 1.5 m initial depth upto 6.0 m cum 21.9
(b) For every 0.50 m after 6.0 m initial depth upto 10.5 m cum 26.7
(c) For every 0.50 m after 10.5 m initial depth upto 18.0 m cum 34.2

2405 Extra rates for quantities of work executed. In or under water or in foul cum 20% of
condition (extra rate for the main item concerned is allowed on account of respective item
slow progress of works)

RES - NIC MPSU 24 - WELL EXCAVATION Page 1 of 1


Page 105 of 132
25 - MISCELLANEOUS II
Code Description Unit Rate
SECTION-A
Reinforced Cement Concrete
2501 Providing and laying in position ready mixed M-25 grade concrete for reinforced cement
concrete work, using cement content as per approved design mix and manufactured in fully
automatic batching plant and transported to site of work in transit mixer for all leads, having
continuous agitated mixer, manufactured as per mix design of specified grade for reinforced
cement concrete work, including pumping of R.M.C. from transit mixer to site of laying,
excluding the cost of centering, shuttering, finishing and reinforcement, including cost of
admixtures in recommended proportions as per IS : 9103 to accelerate / retard setting of
concrete, improve workability without impairing strength and durability as per direction of
the Engineer - in - charge.
Note : Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as
per design mix is payable/ recoverable separately)
(a) All works upto plinth level. cum 5652.00
(b) All works above plinth level and upto floor V level. cum 5790.60
Brick Work
2502 Providing and laying minimum 100mm thick autoclaved aerated fly ash cement concrete cum 5148.00
(AAC) masonry blocks in super structure above plinth level up to floor two level in cement
mortar 1:4 (1 cement : 4 sand ) The rate includes providing and placing in position 2 Nos. 8
mm dia M.S. bars at every third course of masonry work.

Wood Work And PVC Work


2503 Providing and fixing aluminium die cast body tubler type universal hydraulic door closer Each 702.00
(having grand logo with ISI, IS 3564, embosed on the body, door weight upto 35kg and door
width upto 700mm) with nessery accessories and screws etc complete.
2504 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws
etc. complete :
(a) 125x64x1.90 mm Each 60.30
(b) 100X58x1.90 mm Each 53.10
(c) 75x47x1.80 mm Each 35.10
(d) 50x37x1.50 mm Each 22.50
2505 Providing and fixing curtain rods of 1.25 mm thick chromium plated brass plate, with two
chromium plated brass brackets fixed with C.P. brass screws and wooden plugs, etc.,
wherever necessary complete :
(a) 12 mm dia. metre 260.10
(b) 20 mm dia. metre 339.30
(c) 25 mm dia. metre 343.80
2506 Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets :
(a) 20 mm dia (heavy type) metre 114.30
(b) 25 mm dia (heavy type) metre 126.90
2507 Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory
windows using wire gaugue with average width of aperture 1.4 mm in both directions with
wire of dia. 0.63 mm all complete.
(a) With 2nd class teak wood beading 62X19 mm. Sqm 900.00
(b) With 12 mm mild steel U beading. Sqm 612.90
2508 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and
clerestory windows using wire gauge with average width of aperture 1.4 mm in both
directions with wire of dia. 0.50 mm all complete.
(a) With 2nd class teak wood beading 62x19 mm. sqm 1520.10
(b) With 12 mm mild steel U beading. sqm 1233.00
2509 Deduct for fixing 75x25 mm hard drawn steel wire fabric of weight not less than 7.75 Kg. Sqm 149.40
per sqm in paneled and glazed door and window shutter instead of glass sheet 4 mm thick.

2510 Providing and fixing IS : 1341 marked M.S. heavy weight butt hinges with necessary screws
etc. complete :
Page 106 of 132
Code Description Unit Rate
(a) 125x90x4.00 mm Each 47.70
(b) 100x75x3.50 mm Each 31.50
(c) 75x60x3.10 mm Each 18.90
(d) 50x40x2.50 mm Each 11.70
2511 Providing and fixing ISI marked oxidised M.S. pressed butt hinges with necessary screws
etc. complete
(a) 125x65x2.12 mm Each 28.80
(b) 100x58x1.90 mm Each 20.70
(c) 75x47x1.70 mm Each 15.30
(d) 50x37x1.50 mm Each 9.00
2512 Providing and fixing ISI marked oxidized M.S. pressed Parliamentary hinges with necessary
screws etc. complete :
(a) 150x125x27x2.80 mm Each 52.20
(b) 125x125x27x2.80 mm Each 49.50
(c) 100x125x27x2.80 mm Each 41.40
(d) 75x100x20x2.24 mm Each 35.10
2513 Providing and fixing ISI marked oxidized M.S. single acting spring hinges with necessary
screws etc. complete :
(a) 150 mm Each 152.10
(b) 125 mm Each 146.70
(c) 100 mm Each 117.90
2514 Providing and fixing ISI marked oxidized M.S. sliding door bolts with nuts and screws etc.
complete :
(a) 300x16 mm Each 153.00
(b) 250x16 mm Each 141.30
2515 Providing and fixing ISI marked stainless steel tower bolt black finish, (Barrel type) with
necessary screws etc. complete :
(a) 250x10 mm Each 133.20
(b) 200x10 mm Each 83.70
(c) 150x10 mm Each 63.90
(d) 100x10 mm Each 45.00
2516 Providing and fixing ISI marked oxidized M.S. door latches conforming to IS:5930 with
screws etc. complete:
(a) 300x20x6 mm Each 64.80
(b) 250x20x6 mm Each 60.30
2517 Providing and fixing ISI marked oxidized M.S. handles conforming to IS:4992 with
necessary screws etc. complete :
(a) 125 mm Each 24.30
(b) 100 mm Each 22.50
(c) 75 mm Each 21.60
2518 Providing and fixing stainless steel safty chain with necessary fixtures for doors. Each 244.80
Conforming to IS specification (Weighting not less than 450 gms.)
2519 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws
etc. complete :
(a) 125x64x1.90 mm Each 60.30
(b) 100X58X1.90 mm Each 53.10
(c) 75x47x1.80 mm Each 35.10
(d) 50x37x1.50 mm Each 22.50
2520 Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with
stainless steel screws etc. complete :
(a) 125x64x2.50 mm Each 68.40
(b) 100x60x2.50 mm Each 54.00
(c) 75x50x2.50 mm Each 41.40
Page 107 of 132
Code Description Unit Rate
2521 Providing and fixing bright finished brass butt hinges with necessary screws etc. complete :

(a) 125x85x5.5 mm (heavy type) Each 410.40


(b) 125x70x4 mm (ordinary type) Each 133.20
(c) 100x85x5.5 mm (heavy type) Each 348.30
(d) 100x70x4 mm (ordinary type) Each 105.30
(e) 75x65x4 mm (heavy type) Each 130.50
(f) 75x40x2.5 mm (ordinary type) Each 66.60
(g) 50x40x2.5 mm (ordinary type) Each 28.80
2522 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc.
complete :
(a) 250x10 mm Each 296.10
(b) 200x10 mm Each 234.90
(c) 150x10 mm Each 198.90
(d) 100x10 mm Each 127.80
2523 Providing and fixing bright finished brass door latch with necessary screws etc. complete :

(a) 300x16x5 mm Each 213.30


(b) 250x16x5 mm Each 202.50
2524 Providing and fixing bright finished brass handles with necessary screws etc. complete :
(a) 125 mm Each 184.50
(b) 100 mm Each 162.90
(c) 75 mm Each 126.90
2525 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer Each 702.00
(having brand logo with ISI, IS:3564, embossed on the body, door weight upto 35kg and door
with upto 700mm) with necessary accessories and screws etc. complete.
2526 Providing and fixing aluminium extruded section body tubular type universal hydraulic door Each 1067.40
closer (having brand logo with ISI, IS:3564, embossed on the body, door weight upto 36kg to
80kg and door with upto 701mm to 1000mm) with double speed adjustment with necessary
accessories and screws etc. complete.
2527 Providing and fixing chromium plated brass handles with necessary screws etc. complete:

(a) 125 mm Each 216.90


(b) 100 mm Each 185.40
(c) 75 mm Each 163.80
2528 Providing and fixing aluminium sliding door bolts ISI marked anodized (anodic coating not
less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with
nuts and screws etc. complete :
(a) 300x16 mm Each 216.90
(b) 250x16 mm Each 175.50
2529 Providing and fixing aluminium tower bolts ISI marked anodized (anodic coating not less
than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with
necessary screws etc. complete:
(a) 300x10 mm Each 102.60
(b) 250x10 mm Each 91.80
(c) 200x10 mm Each 73.80
(d) 150x10 mm Each 62.10
(e) 100x10 mm Each 49.50
2530 Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than
grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary
screws etc. complete:
(a) 125 mm Each 67.50
(b) 100 mm Each 49.50
(c) 75 mm Each 41.40
Page 108 of 132
Code Description Unit Rate
2531 Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic
coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour
and shade with necessary screws etc. complete.
(a) Single rubber stopper Each 31.50
(b) Twin rubber stopper Each 77.40
2532 Providing and fixing bright finished 100mm mortice lock with 6 levers without pair of Each 432.00
handles for aluminium door with necessary screws etc complete (Best make of approved
quality) as per direction of Engineer-in-charge.
2533 Providing and fixing magnetic catcher in cupboard / ward robe shutters including fixing with
necessary screws etc. Complete (Best make of approved quality).
(a) Triple strip vertical type. Each 25.20
(b) Double strip (horizontal type). Each 20.70
2534 Providing and fixing powder coated telescopic drawer channels with necessary screws etc.
complete as per directions of Engineer- in-charge.
(a) 300mm long Each 188.10
(b) 450mm long Each 230.40
(c) 500mm long Each 271.80
2535 Providing and fixing sliding arrangement in racks/ cupboards/cabinets shutter by P/F Each 12.60
stainless steel rollers to run inside C or E aluminium channel section (The payment of C or E
channel shall be made separately)
2536 Providing and fixing partition upto ceiling height consisting of G.I. frame and required board
including providing and fixing of frame work made of special section power pressed/ roll
form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor
and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to
the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm
dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the
studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick
fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610mm
centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of
partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at
spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25
mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm
centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid
through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5
mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal
to metal flat head screws, including jointing and finishing to a flush finish with recommended
jointing compound, jointing tape, angle beads at corner (25 mm x 25 mm x 0.5 mm), joint
finisher and two coats of primer suitable for board as per manufacture's specification and
direction of engineer in charge all complete.

(a) 75 mm overall thickness partition with 12.5 mm thick double skin fire rated board sqm 1090.80
conforming to IS: 2095: part I.
(b) 75mm overall thickness partition with 12.5 mm thick double skin tapered edged plain sqm 814.50
Gypsum board conforming to IS: 2095: part I
(c ) 66mm overall thickness Partition with 8mm thick double skin Calcium Silicate Board sqm 1341.90
made with Calcareous and Siliceous materials reinforced with cellulose fiber
manufactured through autoclaving process with Compressive Strength 225 kg/sq.cm,
Bending Strength 100 kg./ sq.cm.
(d) 66mm overall thickness partition using 8mm thick double skin non- asbestos sqm 1090.80
multipurpose cement board reinforced with cellulose fibre manufactured through
autoclaving process (High pressure steam cured) as per IS: 14862 with suitable fibre
cement screw.
2537 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed Sqm 978.30
shutters for doors, windows and clerestory windows (Area of opening for panel inserts
excluding portion inside grooves or rebated to be measured). Panelling for panelled and
glazed shutters 25 mm to 40 mm thick :
Prelaminated with decorative lamination on both side exterior Grade-I MDF Board 12mm
thick conforming to IS 14587
Page 109 of 132
Code Description Unit Rate
2538 Providing and fixing factory made UPVC door frame made of uPVC extruded section having `
an overall dimension as below (tolerance ±1mm) with wall thickness 2.0mm ( ± 0.2mm),
corners of the door frame to be jointed with galvanized brackets and stainless steel
screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by
galvanized M.S. tube of size 19 X 19mm and 1mm (± 0.1mm) wall thickness and 3 nos.
stainless steel hinges fixed to the frame complete as per manufacturers specification and
direction of Engineer-in-Charge

(a) Extruded section profile size 48x40 mm. metre 182.70


(b) Extruded section profile size 42x50 mm. metre 187.20
2539 Providing and fixing to existing door frames.
(a) 24 mm thick factory made PVC door shutters made of styles and rails of a uPVC Sqm 2599.20
hollow section of size 59x24 mm and wall thickness 2 mm ( ± 0.2 mm) with inbuilt
edging on both sides. The styles and rails mitered and joined at the corners by means
of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm
and stainless steel screws. The styles of the shutter reinforced by inserting galvanized
M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made
up of 'H' section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm)
wall thickness fixed to the shutter styles by means o fplastic/ galvanized M.S. 'U'
cleats. The shutter frame filled. with a uPVC multi-chambered single panel of size not
less than 620 mm, having over all thickness of 20 mm and 1 mm ( ± 0.1 mm) wall
thickness. The panels filled vertically and tie bar at two places by inserting
horizontally 6 mm galvanized M.S. rod and fastened with nuts and washers, complete
as per manufacturer's specification and direction of Engineer-in-Charge. (For W.C.
and bathroom door shutter).

(b) 30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and Sqm 2808.90
rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm (± 0.2 mm)
with inbuilt decorative moulding edging on one side. The styles and rails mitered and
joined at the corners by means of M.S. galvanized/plastic brackets of size 75x220 mm
having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter
reinforced by inserting galvanized M.S. tube of size 25x20 mm and 1 mm (± 0.1 mm)
wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size
100x30 mm and 2 mm (± 0.2 mm) wall thickness fixed to the shutter styles by means
of plastic/ galvanized M.S. 'U' cleats. The shutter frame filled with a uPVC multi-
chambered single panel of size not less than 620 mm, having over all thickness of 20
mm and 1 mm (± 0.1 mm) wall thickness . The panels filled vertically and tie bar at
two places by inserting horizontally 6 mm galvanized M.S. rod and fastened with nuts
and washers, complete as per manufacturer's specification and direction of Engineer-in-
charge.

( c) 25 mm thick PVC flush door shutters made out of a one piece multi chamber extured Sqm 2703.60
PVC sections of the size of 762mm x 25mm or less as per requiement with an
averaqge wall thickness of 1mm (± 0.3mm) PVC foam end cap of size 23 x10mm or
provided both vertical edges to ensure the overall thickness of 25mm. An M.S. tube
having dimensions 19mm x 19mm and 1.0mm (±0.1mm) is inserted along the hinge
side of the door. Core of the door shutter should be filled with high density
polyurethane foam. The top and bottom edges of the shutter or covered with en end cap
of the sizw 25mm x 11mm doorm shutter shall be reinforced with special polymeric
reinforcements as per manufucred specifications and direction of Engineer-in-Charge
to take up necessary hardware and fixtures. Stickers indicating the locations of
hardware will be pasted at appropiate places.

2540 Providing and fixing factory made P.V.C. door frame of size 50x47mm with a wall thickness metre 434.70
of 5mm, made out of extruded 5mm rigid PVC foam sheet mitreed at corners and joined with
2 Nos. of 150mm long brackets of 15x15mm M.S. square tube, the vertical door frame
profiles to be reinforced with 19x19mm M.S. square tube of 19 gauge, EPDM rubber gasket
weather seal to be provided through out the frame. The door frame to be fixed to the wall
using M.S. screws of 65/100mm size complete as per manufacturers specification and
direction of Engineer-in-Charge.
Page 110 of 132
Code Description Unit Rate
2541 Providing and fixing PVC rigid foam sheet 1mm thick on existing door shutters (bathroom sqm 563.40
and W.C. doors) using synthetic rubber based adhesive.
2542 Providing and fixing factory made panel PVC door shutter consisting of frame made out of 0.00
M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for styles and 15x15mm for top
and bottom rails. M.S. frame shall have a coat of steel primers of approved make and
manufacture . M.S. frame covered with 5mm thick heat moulded PVC 'C' channel of size
30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in
45degree angle on both side forming styles; and 5mm thick, 95mm wide PVC sheet out of
which 75mm shall be flat and 20mm shall be tapered in 45 degree on the inner side to form
top and bottom rail and 115mm wide PVC sheet out of which 75mm shall be flat and 20mm
shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided
both side of the panel. 10mm (5mmx2) thick, 20mm wide cross PVC sheet be provided as
gap insert for top rail and bottom rail. paneling of 5mm thick both side PVC sheet to be fitted
in the M.S. frame welded/ sealed to the styles and rails with 7mm (5mm+2mm) thick x
15mm wide PVC sheet beading on inner side, and joined together with solvent cement
adhesive. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior
side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer-
in-charge. Manufacturer’s specification and drawing.

(a) 30 mm thick plain PVC door shutters. Sqm 2734.20


(b) 30 mm thick pre laminated PVC door shutters. sqm 3400.20
2543 Providing and fixing factory made 30 mm thick door shutter made of solid PVC foam profile. Sqm
The styles and rails shall be of size 75 mmx30 mm having wall thickness 5 mm. The styles,
top and bottom rails shall have one side wall thickness of 15 mm integrally extruded on the
hinge side of the profile for better screw holding power. The styles and rails shall be
reinforced with M.S. tubes of size 33 mmx17 mmx 1 mm, painted with primer, all four
corners of reinforcement to be welded or sealed. Solid PVC extruded bidding (push fit type)
will be set inside the styles and the rails with a cavity, to receive single piece extruded 5 mm
PVC sheet as panel. The styles and rails will be mitred cut and joint with the help of PVC
solvent cement and self driven self tapping screws. Single piece extruded solid PVC lock rail
of size 100 mm x 30 mm with wall thickness 5 mm and 15 mm integrally extruded in the
middle of the lock rail and fixed with styles with the help of PVC solvent cement and self
driven self tapping screws of size 100 mmx8 mm complete as per manufacturer's
specifications and direction of Engineer-in-charge:

(a) Non decorative finish. sqm 2734.20


(b) Decorative finish (both side wood grained finish). sqm 3257.10
Page 111 of 132
Code Description Unit Rate
2544 Providing and fixing factory made 100% solid PVC door shutter made from coextruded
three layer rigid PVC foam sheet (Single Extruded) with density not less than 600kg/cum
outer layers 1mm thick to be rigid UPVC with density not be less than 1400kg/cum
manufactured by an ISO:9001-2000 certificed company.
(a) 24mm thick plain solid PVC flush door shutter Sqm 3766.50
(b) 28mm thick plain solid PVC flush door shutter Sqm 4559.40
2545 Proving and fixing factory made laminated 100% solid PVC flush door shutter (28mm
thickness) made from rigid PVC foam sheet (Single Extruded) with density 600kg/cum and
laminated on both sides by laminated sheet/PVC foil lamination at the manufacturing process
itself.
(a) 28mm thick prelaminated solid PVC flush door shutter Sqm 5240.70
(b) 30mm thick prelaminated solid PVC flush door shutter Sqm 5535.00
2546 Proving and fixing factory made 100% solid wood plasitc composite (WPC) door frames
made from wood plastic composite (single extruded process) material with density
0.78kg/cum and manufactured by ISO:9001-2000 certificed company. Water absorption not
more than 0.01% cum.
(a) WPC door frame-single rebate (90mm x 45mm) metre 716.40
(b) WPC door frame-single rebate (120mm x 40mm) metre 806.85
(c ) WPC door frame-single or double rebate (125mm x 65mm) metre 1064.03
Steel Work
2547 Providing and fixing carbon steel galvanised (minimum coating 5 micron) dash fastener of 10
mm dia double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head,
comprising of 10 mm dia polyamide PA 6 grade sleeve, including drilling of hole in frame,
concrete/ masonry, etc. as per direction of Engineer-in-charge.
(a) 10 x60 mm each 51.08
(b) 10 x80 mm each 56.30
(c ) 10 x120 mm each 70.20
(d) 10 x140 mm each 75.96
(e) 10 x160 mm each 98.73
2548 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, Kg 714.38
plates etc. including welding, grinding, buffing, polishing and making curvature (wherever
required) and fitting the same with necessary stainless steel nuts and bolts complete i/c
fixing the railing with necessary accessories and stainless steel dash fasteners , stainless steel
bolts etc., of required size, on the top of the floor or the side of waist slab with suitable
arrangement as per approval of Engineer-in-charge. ( for payment purpose only weight
of stainless steel members shall be considered excluding fixing accessories such as nuts,
bolts, fasteners etc.)

2549 Providing and fixing glass panes/steel sheet/fibre sheet with putty and glazing clips in steel
doors, windows, clastery windows all complete.
(a) With 4mm thick glass pans sqm 713.21
(b) With 5.5mm thick glass pans sqm 785.66
(c) With 1mm thick steel sheet i/c 10mm x 10mm x 1.6mm box beading sqm 824.31
(d) With 2mm thick reinforced polymer (FRP) sqm 550.62
2550 Providing and fixing G.I. chain link fabric fencing of required width and mesh size including
strengthening with 2mm dia wire or nuts, bolts and washers as required complete with posts
of specified material and of standard design placed and embedded in cement concrete blocks
45x45x60cm of mix 1:5:10 (1cement :5 sand :10 graded stone aggregate 40mm nominal size)
every 15th post, last but one end post and corner post shall be strutted on both sides and end
post on one side only and struts embedded in cement concrete blocks 70x45x50cm of the
same mix, as per the direction of Engineer- in-charge.

(a) Made of G.I. wire. kg 119.70


(b) Made of G.I. wire, PVC coated to achieve outer dia. not less than 5mm in required kg 124.20
colour and shade.
Page 112 of 132
Code Description Unit Rate
2551 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm sqm 516.42
made of G.I. wire of dia. 3mm including strengthening with 2mm dia. wire or nuts, bolts and
washers as required complete with posts of specified material and of standard design placed
and embedded in cement concrete blocks 45x45x60cm of mix 1:5:10 (1cement :5 sand : 10
graded stone aggregate 40mm nominal size) every 15th post, last but one end post and corner
post shall be strutted on both sides and end post on one side only and struts embedded in
cement concrete blocks 70x45x50cm of the same mix, as per the direction of Engineerin-
charge.

Flooring
2552 Marble stone flooring with 18 mm thick marble stone (sample of marble shall be approved
by Engineer-in-charge) over 20 mm (average) thick base of cement mortar 1:4 (1 cement:4
sand)laid and jointed with grey cement slurry including rubbing and polishing complete with
: (Area of Slabs over 0.50sqm)

(a) Makrana white second quality. Sqm 2745.90


(b) Raj Nagar plain. Sqm 1242.90
(c) Agaria White/Morgarh Sqm 1693.80
(d) katani marble Sqm 1399.50
(e) Black Zebra. Sqm 1183.50
(f) Udaipur/Baroda green marble Sqm 1484.10
(g) Pink plain marble. Sqm 1339.20
(h) Jaisalmer yellow Sqm 1423.80
2553 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (having Sqm 843.30
thicness 6-7mm thickness) of approved make in all colours, shades except burgundy, bottle
green, black of size300 x 450mm or more skirting, risers of steps and dados over 12 mm
thick bed of cement Mortar 1:3 (1 cement : 3 sand) and jointing with grey cement slurry @
3.3kg per sqm including pointing in white cement mixed with pigment of matching shade
complete.
2554 Providing and laying rectified glazed Ceramic floor tiles 300 x 300mm or more (having sqm 864.90
thickness 9-10 mm) of 1st quality conforming to IS : 15622 of approved make in colours
White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4
sand) including grouting the joints with white cement and matching pigment etc., complete.

2555 Providing and laying rectified glazed Ceramic floor tiles 300 x 300mm or more (having sqm 897.30
thickness 9-10mm) of 1st quality conforming to IS : 15622 of approved make in all
colours, shades, except White, Ivory, Grey, Fume, Red Brown laid on 20mm thick Cement
Mortar 1:4 (1 Cement : 4 sand) including pointing the joints with white cement and matching
pigments etc., complete.

2556 Providing and laying vitrified floor tiles in different sizes with water absorption less than
0.08% and confirming to IS:15622 of approved make in all colours and shades laid on 20mm
thick cement mortar 1:4 (1cement : 4sand) including grouting the joints with white cement
and matching pigments etc., complete.
(a) Size of tile 500X 500 x 9-10 mm sqm 777.60
(b) Size of tile 600X 600 x 9-10mm sqm 804.60
(c ) Size of tile 800 X 800 10-12mm sqm 1306.80
(d) Size of tile 1000 X 1000 10-12mm sqm 1458.00
2557 Add extra in above item for providing and fixing on wall/skirting. Sqm 10 per cent

2558 Deduct for not using 20mm thick cement mortar 1:4 (1cement : 4sand) bedding in laying of sqm 323.10
floors tiles.
2559 Fixing glazed/ Ceramic/Rectified/ Vitrified floor tiles with cement based high polymer sqm 315.00
modified quick-set tile adhesive (Water based) conforming to IS: 15477, in average 3mm
thickness.
Page 113 of 132
Code Description Unit Rate
2560 Providing and laying 60 mm thick factory made cement concrete interlocking paver block of sqm 527.40
M-30 grade made by block making machine with strong vibratory compaction and of
approved size and shape laid in required colour and pattern over and including 50 mm thick
compacted bed of course sand filling the joints with sand etc. all complete as per the
direction of engineer in charge.
2561 Providing and laying factory made coloured chamfered edge Cement Concrete paver blocks sqm 631.80
of required strength, thickness and size/shape, made by table vibratory method using PU
mould, laid in required colour and pattern over 50mm thick compacted bed of stone dust,
compacting and proper embedding/laying of inter locking paver blocks into the bedding layer
through vibratory compaction by using plate vibrator, filling the joints with sand and cutting
of paver blocks as per required size and pattern, finishing and sweeping extra sand including
locking edges with M 15 cement concrete in footpath, parks, lawns, drive ways or light
traffic parking etc. complete as per manufacturer's specifications and direction of Engineerin-
Charge. 60mm thick C.C. paver block of M-35 grade with approved colour, design and
pattern.
2562 Providing and laying saw cut 18mm thick mirror polished pre moulded (whereever required)
and pre polished machine cut granite stone of required size and shape of approved shade,
colour and texture in flooring laid over 20mm thick base of cement mortar 1:4 (1 cement :4
sand) including grouting the joints with white cement mixed with maching pigment, epoxy
touch ups etc complete. as per direction of Engineer in charge.
Black
(a) area of slab less than 0.50 sqm Sqm 3129.30
(b) area of slab more than 0.50 sqm Sqm 3348.00
All shades/colour other than black
(a) area of slab less than 0.50 sqm Sqm 3238.20
(b) area of slab more than 0.50 sqm sqm 3325.50
Roofing And Ceiling
2563 Providing & fixing UV stabilized fiberglass reinforced plastic sheet roofing up to any pitch
including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8mm dia. G.I
plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The
sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3%
Ultra-violet stabilizer in resin system under approximately 2400 psi and hot cured. They shall
be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192
and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or
smooth as specified.
(a) 2mm thick corrugated (2.5" or 4.2" or 6") or step down (2" or 3" or 6" ) as specified. sqm 927.90
(b) 2mm thick flat. sqm 859.50
2564 Providing and fixing on wall face unplasticised Rigid PVC Rain water pipes conforming to
IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm
gap for thermal expansion.
(a) Single socketed pipes
(i) 75 mm diameter (minimum wall thicness 1.8mm) Each 122.40
(ii) 110 mm diameter (minimum wall thicness 2.2mm) Each 214.20
Page 114 of 132
Code Description Unit Rate
2565 Providing and fixing on wall face Unplasticised - PVC moulded fittings/ accessories for
Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including
jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.

(a) Coupler
(i) 75 mm (minimum wall thickness 1.8mm) each 105.30
(ii) 110 mm (minimum wall thickness 2.2mm) each 138.60
(b) Single push fit Coupler :
(i) 75 mm (minimum wall thickness 1.8mm) each 126.00
(ii) 110 mm (minimum wall thickness 2.2mm) each 175.50
(c ) Single tee with door
(i) 75x75x75 mm (minimum wall thickness 1.8mm) each 207.00
(ii) 110x110x110 mm (minimum wall thickness 2.2mm) each 311.40
(d) Single tee without door
(i) 75x75x75 mm (minimum wall thickness 1.8mm) each 180.90
(ii) 110x110x110 mm (minimum wall thickness 2.2mm) each 239.40
(e) Bend 87.5°
(i) 75 mm bend (minimum wall thickness 1.8mm) each 105.30
(ii) 110 mm bend (minimum wall thickness 2.2mm) each 154.80
(f) Shoe (Plain)
(i) 75 mm Shoe (minimum wall thickness 1.8mm) each 157.50
(ii) 110 mm Shoe (minimum wall thickness 2.2mm) each 270.00
2566 Providing and fixing Unplasticised -PVC pipe clips of approved design to Unplasticised -
PVC rain water pipes by means of bombay nail of required length including making good the
wall etc. complete.
(a) 75 mm (minimum wall thickness 1.8mm) each 87.30
(b) 110 mm (minimum wall thickness 2.2mm) each 102.60
2567 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter each 38.70
and weighing not less than 440 grams.
2568 Providing and fixing false ceiling at all height including providing and fixing of frame work
made of special sections, power pressed from M.S. sheets and galvanized with zinc coating
of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25
mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one
flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts
other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with
nuts and bolts of required size and other end of angle hanger fixed with intermediate G.I.
channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre to which the
ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each
having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction
perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x
230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick
27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to
wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws
@ 230 mm interval, including fixing of 10mm thick plaster of Paris (gypsum anhydrous)
sheet to ceiling section and perimeter channels with the help of dry wall screws of size
3.5x25mm at 230mm interval including jointing and finishing to a flush finish of tapered and
square edges of POP board with jointing compound (POP paste) including the cost of making
openings for light fittings, grills, diffusers cutouts made with frame of perimeter channels
suitably fixed all complete as per drawing, specifications and direction of the Engineer-in-
charge.
(a) Flat surfaces Sqm 608.40
(b) Curved surfaces Sqm 673.20
2569 Extra for any sunk or raised mouldings in the plaster of Paris (Gypsum anhydrous) ceiling Sqm 157.50

2570 Extra for providing plaster of Paris (Gypsum anhydrous) ceiling above 5metres height from Sqm 53.10
floor level.
Page 115 of 132
Code Description Unit Rate
2571 Providing and fixing false ceiling at all height including providing and fixing of frame work
made of special sections, power pressed from M.S. sheets and galvanized with zinc coating
of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25
mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one
flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts
other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with
nuts and bolts of required size and other end of angle hanger fixed with intermediate G.I.
channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre to which the
ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each
having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction
perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x
230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick
27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to
wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws
@ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter
channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including
jointing and finishing to a flush finish of tapered and square edges of the board with
recommended jointing compound , jointing tapes , finishing with jointing compound in 3
layers covering upto 150 mm or both sides of joint and two coats of primer suitable for
board, all as per manufacturer’s specification and also including the cost of making openings
for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably
fixed, all complete as per drawings, specification and direction of the Engineer in Charge but
excluding the cost of painting with :
(a) 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- Part I. sqm 675.00
(b) 12.5 mm thick tapered edge gypsum fire resistant board conforming to IS: 2095- Part sqm 779.40
I. mm thick tapered edge gypsum moisture resistant board.
(c ) 12.5 sqm 828.00
(d) Fully Perforated Gypsum Plaster Board of size 1200 x 2400x12.5 mm having approx. sqm 1509.30
2572 15 %
Providing perforated
and area withboard
fixing insulating perforation
ceilingsize andthick
12 mm pattern
of as approved
approved by thewith
quality Engineer-in-
necessary
nails etc. complete (frame work to be paid separately):
(a) Natural colour insulating board Sqm 495.00
(b) White face insulating board Sqm 552.60
(c ) Flame retardant face insulating board Sqm 552.60
2573 Providing and fixing flat pressed 3 layer medium density particle board or graded particle
board (Grade I) IS: 3087, 12 mm thick marked in ceiling with necessary nails etc. complete
(frame work to be paid separately) :
2574 (a) 12mm thick Sqm 569.70
2575 Providing and fixing plain Multipurpose Cement board 6mm thick ( High Pressure steam
cured ) as per IS : 14862 : 2000 ) with suitable fibre cement screw in ceiling etc. complete
(frame work to be paid separately) :
(a) 6 mm thick cement board sqm 385.20
2576 Extra for Circular cutting and waste in ceiling with:
(a) Natural colour insulating board 12 mm thick metre 135.00
(b) White face insulating board 12 mm thick metre 142.20
(c) Flame retardant face insulating board 12 mm thick metre 142.20
2577 Extra for providing and fixing ceiling to curved surfaces in narrow widths Sqm 90.00
Page 116 of 132
Code Description Unit Rate
2578 Providing and fixing false ceiling with 12 mm thick plain/ semi perforated or with design Sqm 600.30
ceiling tiles of BWP type phenol formaldehyde synthetic resin bonded pressed particle board
conforming to IS:3087 finished with a coat of aluminium primer on both sides & edges and
two coats of synthetic enamel paint of approved quality on exposed face fixed to a grid made
out of anodized aluminium(with 15 micron anodic coating) T-sections 35 x15x1.5 mm size
main runners and cross runners 23.5x19x1.5 mm fixed to main runners placed 600 mm centre
to centre both ways so as to form a grid of 600 mm square. The frame work shall be
suspended from ceiling by level adjusting hangers of 6 mm dia M.S rod fixed to roof slab by
means of ceiling cleats. The suspenders shall be placed 600x 1200 mm centre to centre
including fixing to the frame with C.P brace screws and applying a priming coat of zinc
chromate yellow primer (aluminium frame work shall be paid separately).

2579 Extra for providing 3 mm thick translucent white acrylic plastic sheets of approved quality in Sqm 387.00
false ceiling instead of 12 mm thick plain/or with design particle board ceiling tiles in item
above.

Finishing Work
2580 Providing and applying plaster of paris punning of 10 mm average thickness over plastered sqm 117.00
surface to prepare the surface even and smooth complete

2581 Providing and applying white cement based putty of average thickness 1mm of approved Sqm 66.60
brand and manufacture, like Birla white/J.K. white or equivalent, over yhe plastered wall
surface to prepare the surface even and smooth i/c all cost of material, labour, and scaffold
etc. in all position complete.

2582 Distempering with oil bound washable distemper of approved brand and manufacture to give Sqm 54.00
an even shade.

(a) New work (two or more coats) over and including water thinable priming coat with
2583 cement(ready
Distempering with 1st quality acrylic distemper primer.
mixed) of approved manufacturer, of sqm 30.60
required shade and colour complete, as per manufacturer's specification.

(a) Two or more coats on new work.

2584 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even Sqm 57.60
shade:
(a) Two or more coats on new work
2585 Finishing walls with textured exterior paint of required shade: Sqm 118.80
New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of
water proofing cement paint applied @2.20 kg/10 sqm.

2586 Finishing walls with Acrylic Smooth exterior paint of required shade:

(a) New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming sqm 78.30
coat of exterior primer applied @ 2.20 kg/ 10 sqm).
2587 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of Sqm 75.60
required shade.
(a) New work (Two or more coats applied @ 1.43 ltr/ 10sqm. over and including base
coat of water proofing cement paint applied @ 2.20 kg/10 sqm).
Page 117 of 132
Code Description Unit Rate
2588 Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using
Primer as per manufacturers specifications :
(a) Two or more coats applied on walls @ 1.25 ltr/10 sqm. over and including one coat of sqm 72.90
Special primer applied @ 0.75 ltr / 10 sqm.
(b) Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more sqm 62.10
coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm
of approved brand or manufacture

(c ) Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or sqm 63.90
more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/
10 sqm of approved brand or manufacture

Repairs to Building Work


2589 Renewing glass panes, with putty and nails wherever necessary including racking out the
old putty
(a) Float glass panes of thickness 4 mm sqm 611.10
(b) Float glass panes of thickness 5.5 mm sqm 683.10
Sanitary Installation
2590 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100mm sand
cast Iron P or S trap, uPVC P or S trap 10 litre low level white P.V.C. flushing cistern,
including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231,
with all fittings and fixtures complete including cutting and making good the walls and floors
wherever required :

(a) White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type Each 2695.50
(b) foot rests. Steel AISI-304(18/8) Orissa pattern W.C. pan of size 585x480 mm with
Stainless Each 6327.90
2591 flushand
Providing pipefixing
and integrated type foot
white vitreous rests.
china pedestal type water closet (European type W.C.
pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern including flush pipe
with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and
fixtures complete including cutting and making good the walls and floors wherever required :

(a) W.C. pan with ISI marked white solid plastic seat and lid Each 2732.40
(b) W.C. pan with ISI marked black solid plastic seat and lid Each 2711.70
2592 Providing and fixing white vitreous china pedestal type water closet (European type) with
seat and lid, 10 litre low level white vitreous china flushing cistern, C.P. flush bend with
fittings, C.I. brackets, 40mm flush bend, overflow arrangement with specials of standard
make and mosquito proof coupling of approved municipal design complete including
painting of fittings and brackets, cutting and making good the walls and floors wherever
required :
(a) W.C. pan with ISI marked white solid plastic seat and lid. Each 4151.70
(b) W.C. pan with ISI marked black solid plastic seat and lid. Each 4131.00
2593 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal
basin of 430x260x350mm and 340x410x265mm sizes respectively with automatic flushing
cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps
complete, including painting of fittings and brackets, cutting and making good the walls and
floors wherever required :
(a) One urinal basin with 5 litre white P.V.C. automatic flushing cistern. Each 2478.60
(b) Range of two urinal basins with 5 litre white P.V.C. automatic flushing cistern. Each 4012.20
(c ) Range of three urinal basins with 10litre white P.V.C. automatic flushing cistern. Each 5680.80

(d) Range of four urinal basins with 10 litre white P.V.C. automatic flushing cistern. Each 7545.60

2594 Providing and fixing white vitreous china flat back half stall urinal of size 80x380x350mm
with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe,
spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I.
trap with outlet grating and other couplings in C.P. brass including painting of fittings and
cutting and making good the walls and floors wherever required:

(a) Single half stall urinal with 5 litre P.V.C. automatic flushing cistern. Each 5010.30
Page 118 of 132
Code Description Unit Rate
(b) Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern. Each 7794.00
(c ) Range of three half stall urinals with 10 litre P.V.C. automatic flushing cistern. Each 11487.60
(d) Range of four half stall urinals with 10 litre P.V.C. automatic flushing cistern. Each 13992.30
2595 Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40
mm C.P. brass waste complete, including painting the fittings and rackets, cutting and
making good the walls wherever required :
(a) White glazed fire clay kitchen sink of size 600x450x250 mm. each 2242.80
2596 Providing and fixing Stainless Steel ISI 304 (18/8) kitchen sink as per IS 13983 with C.I.
brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting
and making good the walls wherever required :
(a) Kitchen sink with drain board
(i) 510x1040 mm bowl depth 250mm. Each 7266.60
(ii) 510x1040 mm bowl depth 225mm. Each 6848.10
(iii) 510x1040 mm bowl depth 200mm. Each 6743.70
(iv) 510x1040 mm bowl depth 178mm. Each 4757.40
(b) Kitchen sink without drain board
(i) 610x510 mm bowl depth 200 mm. Each 4124.70
(ii) 610x460 mm bowl depth 200 mm. Each 3915.90
(iii) 470x420 mm bowl depth 178 mm. Each 3079.80
2597 Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain
with rubber plug 40mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass
unions complete including painting of fittings and brackets, cutting and making good the wall
wherever required

(a) Size 450x300x150mm Each 2106.90


(b) Size 600x450x200mm Each 2995.20
2598 Providing and fixing P.V.C. low level flushing cistern with manually controlled device
(handle lever) conforming to IS : 7231, with all fittings and fixtures complete.
(a) 10 litre capacity - White Each 850.50
(b) 10 litre capacity - coloured Each 933.30
Water Supply
2599 Providing and fixing Polyethelene-Aluminium-Polyethelene (PE-AL-PE) Composite Pressure
Pipes conforming to IS - 15450 U.V. stabilised with carbon black having thermal stability for
hot and cold water supply, capable to withstand temperature up to 80° C including all special
fittings of composite material (engineering plastic blend and brass inserts wherever required)
e.g. elbows, tees, reducers, couplers and connectors etc. with clamps at 1.00 metre spacing.
this includes testing of joints complete as per direction of the Engineer in charge.

Internal work - Exposed on wall


(a) 1216 (16 mm OD) pipe (minimum wall thickness 1.75mm) metre 173.70
(b) 1620 (20 mm OD) pipe (minimum wall thickness 2mm) metre 217.80
(c ) 2025 (25 mm OD) pipe (minimum wall thickness 2.45mm) metre 276.30
(d) 2532 (32 mm OD) pipe (minimum wall thickness 2.8mm) metre 358.20

25-100 Providing and fixing Polyethelene-Aluminium-Polyethelene (PE-AL-PE) Composite Pressure


Pipes conforming to IS - 15450 U.V. stabilised with carbon black having thermal stability for
hot and cold water supply, capable to withstand temperature up to 80° C including all special
fittings of composite material (engineering plastic blend and brass inserts wherever required
) e.g. elbows ,tees ,reducers, couplers and connectors etc. with clamps at 1.00 metre spacing.
including the cost of cutting chases and testing of joints complete as per direction of the
engineer in charge.
Concealed work including cutting chases and making good the wall etc.
(a) 1216 (16 mm OD) pipe (minimum wall thickness 1.75mm) metre 269.10
(b) 1620 (20 mm OD) pipe (minimum wall thickness 2mm) metre 324.00
(c ) 2025 (25 mm OD) pipe (minimum wall thickness 2.45mm) metre 396.90
(d) 2532 (32 mm OD) pipe (minimum wall thickness 2.8mm) metre 497.70
Page 119 of 132
Code Description Unit Rate
25-101 Providing and fixing Polyethelene-Aluminium-Polyethelene (PE-AL-PE) Composite Pressure
Pipes conforming to IS - 15450 U.V. stabilized with carbon black having thermal stability
for hot and cold water supply, capable to withstand temperature up to 80° C including all
special fittings of composite material (engineering plastic blend and brass inserts wherever
required ) e.g. elbows ,tees ,reducers, couplers and connectors etc. with trenching, refilling
and testing of joints complete as per direction of the engineer in charge.
External work
(a) 1216 (16 mm OD) pipe (minimum wall thickness 1.75mm) metre 171.00
(b) 1620 (20 mm OD) pipe (minimum wall thickness 2mm) metre 211.50
(c ) 2025 (25 mm OD) pipe (minimum wall thickness 2.45mm) metre 265.50
(d) 2532 (32 mm OD) pipe (minimum wall thickness 2.8mm) metre 340.20
25-102 Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes SDR 7.4 U V
stabilized and anti - microbial fusion welded, having thermal stability for hot and cold water
supply including all PP - R plain and brass threaded polypropylene random fittings i/c fixing
the pipe with clamps at 1.00 m spacing. This includes testing of joints complete as per
direction of Engineer in Charge.
Internal work - Exposed on wall
(a) PN - 16 Pipe, 16 mm OD metre 91.80
(b) PN - 16 Pipe, 20 mm OD metre 123.30
(c ) PN - 16 Pipe, 25 mm OD metre 167.40
(d) PN - 16 Pipe, 32 mm OD metre 256.50
Drainage
25-103 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement
mortar in the proportion of 1:1 (1 cement : 1 sand) including testing of joints etc. complete :
Excavation to be paid seperataly

(a) 100 mm diameter metre 175.50


(b) 150 mm diameter metre 234.00
(c ) 200 mm diameter metre 303.30
(d) 230 mm diameter metre 414.90
(e) 250 mm diameter metre 456.30
(f) 300 mm diameter metre 612.00
25-104 Providing and laying cement concrete 1:5:10 (1 cement : 5sand : 10 graded stone aggregate
40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design:
(a) 100 mm diameter S.W. Pipe RM 427.50
(b) 150mm diameter S.W. Pipe RM 522.00
(c) 200 mm diameter S.W. Pipe RM 609.30
(d) 230 mm diameter S.W. Pipe RM 655.20
(e) 250 mm diameter S.W. Pipe RM 703.80
(f) 300 mm diameter S.W. Pipe RM 789.30
Page 120 of 132
Code Description Unit Rate
25-105 Providing and laying cement concrete 1:5:10 (1 cement : 5 sand : 10 graded stone aggregate
40 mm nominal size) upto haunches of S.W. pipes including bed concrete as per standard
design :
(a) 100 mm diameter S.W. pipe metre 203.40
(b) 150 mm diameter S.W. pipe metre 329.40
(c ) 200 mm diameter S.W. pipe metre 387.00
(d) 230 mm diameter S.W. pipe metre 418.50
(e) 250 mm diameter S.W. pipe metre 450.00
(f) 300 mm diameter S.W. pipe metre 519.30
25-106 Providing and laying below ground unplasticised PVC pipe to with stand working pressure of
4 kg/cm2 soild waste pipes confirming to IS:13592 and IS:4985 including jointing with seal
ring confirming to IS :5282 leaving 10mm gap for thermal expansion all necessary fittings
etc. complete. Excavation to be paid seperately
(a) 110 mm diameter OD RM 210.60
(b) 160 mm diameter OD RM 429.30
(c) 200 mm diameter OD RM 675.90
(d) 250 mm diameter OD RM 874.80
(e) 300 mm diameter OD RM 1108.80
25-107 Providing and laying cement concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20
mm nominal size) all-round PVC. pipes including bed concrete as per standard design:
(a) 110 mm diameter PVC. pipe RM 518.40
(b) 160 mm diameter PVC. pipe RM 633.60
(c ) 200 mm diameter PVC. pipe RM 738.90
(d) 250 mm diameter PVC. pipe RM 854.10
(e) 300 mm diameter PVC pipe RM 970.20
25-108 Providing and laying cement concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20
mm nominal size) up to haunches of PVC. pipes including bed concrete as per standard
design :
(a) 110 mm diameter PVC. Pipe RM 246.60
(b) 160 mm diameter PVC. pipe RM 399.60
(c ) 200 mm diameter PVC. pipe RM 468.90
(d) 250 mm diameter PVC. pipe RM 546.30
(e) 300 mm diameter PVC pipe RM 630.00
25-109 Providing and fixing square-mouth S.W. gully trap class SP1 complete with C.I. grating
brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside)
the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per
standard design :

(a) 100x100 mm size P type


(b) With well burnt bricks Each 1587.60
(c ) With Sewer bricks conforming to IS : 4885 Each 1501.20
(d) 150 x 100 mm size P type.
(e) With well burnt bricks Each 1622.70
(f) With sewer bricks conforming to IS : 4885 Each 1536.30
(g) 180x150 mm size P type
(h) With well burnt bricks each 1721.70
(i) With Sewer bricks conforming to IS : 4885 each 1636.20
Page 121 of 132
Code Description Unit Rate
25-110 Providing and fixing in position precast R.C.C. manhole cover and frame of required shape
and approved quality
(a) L D- 2.5
(i) Rectangular shape 600x450mm internal dimensions each 1106.10
(ii) Square shape 450mm internal dimensions each 940.50
(iii) Circular shape 450mm internal diameter each 888.30
(b) M D - 10
(i) Square shape 450mm internal dimension each 1064.70
(ii) Circular shape 500mm internal diameter each 988.20
(c) H D - 20
(i) Circular shape 560 mm internal diameter each 1539.90
(i) EHD - 35
(ii) Circular shape 560 mm internal dia. each 1696.50
25-111 Supplying and fixing C.I. cover 300x300 mm without frame for gully trap (standard pattern) each 246.60
the weight of cover to be not less than 4.5kg.

Aluminium Work
25-112 Providing and fixing aluminium work for doors, windows, ventilators and partitions with
extruded built up standard tubular sections/ appropriate Z sections and other sections of
approved make conforming to IS: 733 and IS : 1285, fixing with dash fasteners of required
dia and size including necessary filling up the gaps at junctions, i.e. at top, bottom and sides
with required EPDM rubber/neoprene gaskit etc. Aluminium sections shall be smooth,rust
free, straight, mitred and jointed mechanically wherever required including cleat angle,
Aluminium snap beading for glazing / panneling,C.P. brass / stainless steel screws, all
complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing,
paneling and dash fasterners to be paid for separately) :

(a) For fixed portion


(i) Anodized aluminium (anodized transparent or dyed to required shade according to IS: kg 317.70
1868, Minimum anodic coating of grade AC 15)
(ii) Powder coated aluminium (minimum thickness of powder coating 50 micron) kg 339.30

(iii) Polyester powder coated aluminium (minimum thickness of polyester powder coating kg 344.70
50 micron)
(b) For shutters of doors, windows and ventilators including providing and fixing hinges/
pivots and making provision for fixing of fittings wherever required including the cost of
EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately).

(i) Anodized aluminium (anodized transparent or dyed to required shade according to IS: kg 360.00
1868, Minimum anodic coating of grade AC 15)

(ii) Powder coated aluminium (minimum thickness of powder coating 50 micron) kg 382.50

(iii) Polyester powder coated aluminium (minimum thickness of polyester powder coating kg 387.90
50 micron)
25-113 Providing and fixing 12mm thick Pre-laminated particle board flat pressed three layer or
graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in
aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel
screws etc. complete as per architectural drawings and directions of engineer-in-charge.

(a) Pre-laminated particle board with decorative lamination on one side and balancing sqm 921.60
lamination on other side.
(b) Pre-laminated particle board with decorative lamination on both sides. sqm 965.70
25-114 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions
etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and
the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic
item) :
Page 122 of 132
Code Description Unit Rate
(a) With float glass panes of 4.0 mm thickness sqm 764.10
(b) With float glass panes of 5.50 mm thickness sqm 838.80
(c ) With float glass panes of 8 mm thickness sqm 1162.80
25-115 Add extra for providing and fixing froasted glass instead of float glass
(a) With glass panes of 4.0 mm thickness sqm 233.10
(b) With glass panes of 5.50 mm thickness sqm 235.80
(c ) With glass panes of 8 mm thickness sqm 235.80
25-116 Providing and fixing double action hydraulic floor spring of approved brand and manufacture
conforming to IS : 6315, having brand logo embossed on the body/ plate with double spring
mechisum and door weight upto125 kg, for doors including cast of cutting floors, embedding
in floors as required and making good the same matching to the existing floor finishing and
cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc.
complete as per the direction of Engineer-in-charge.
(a) With stainless steel cover plate- minimum 1.25 mm thickness Each 1810.80
(b) With brass cover plate- minimum 1.25 mm thickness Each 1967.40
25-117 Providing and fixing powder coated aluminium work (minimum thickness of powder coating kg 412.20
50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in
frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless
steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs
@ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm
dia. with necessary cadmium plated machine screws all complete as per approved
architectural drawings and direction of the Engineer-in-charge (level adjusting hangers,
ceiling cleats and expansion hold fasteners to be paid for separately).

25-118 Providing and fixing 6 mm dia. G.I. level adjusting hangers (upto 1200mm length) fixed to Each 119.70
roof slabs by means of ceiling cleats made out of G.I. flat 40x3mm size 60mm long and
expansion hold fasteners 12.5 mm dia. 50mm long complete as per direction of Engineer -in-
charge
25-119 Providing and fixing machine moulded aluminium covering of approved pattern and design,
made out of machine cut aluminium sheet and machine holed for receiving dash fastener,
over expansion joints on vertical surfaces/ceiling floors, the fixing on plate in one row on one
side of joint only shall be done with stainless steel dash fasteners of 8 mm dia and 75 mm
long bolt including providing aluminium washers 2 mm thick and 15 mm dia, at a staggered
pitch of 200mm centre to centre including drilling holes in the receiving surface and
providing expandable plastic sleeves in holes etc. complete as per direction of Engineer-in-
charge :
(a) Anodised aluminium sheet 2.5mm thick (anodised transparent or dyed to required kg 432.00
shade according to IS: 1868, Minimum anodic coating of grade AC 15)

(b) Powder coated aluminium sheet 2.5mm thick (minimum thickness of powder coating kg 453.60
50 micron)
25-120 Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by metre 73.80
providing weather silicon sealant over backer rod of approved quality as per architectural
drawings and direction of Engineer-in-charge complete.
(a) Upto 5mm depth and 5 mm width
25-121 Extra for applying additional anodic coating AC 25 instead of AC 15 to aluminium extruded
sections.
(a) For fixed portion kg 15.30
(b) For shutters of doors, windows & ventilators. kg 15.30
25-122 Providing and fixing double glazed hermetically sealed glazing in aluminium windows, Sqm 3125.70
ventilators and partition etc. with 6 mm thick clear float glass both side having 12 mm air
gap including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant
(Both primary and secondary sealant) etc. as per specifications, drawings and direction of
Engineer-incharge complete.
25-123 Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick and 2100
mm long with SS screws etc .complete as per direction of Engineer-in-Charge.

(a) Anodized (AC 15 ) aluminium tubular handle bar each 448.20


(b) Powder coated minimum thickness 50 micron aluminium tubular handle bar. each 482.40
Page 123 of 132
Code Description Unit Rate
(c ) Polyester powder coated minimum thickness 50 micron aluminium tubular handle bar each 490.50

25-124 Providing and fixing 100mm brass locks (best make of approved quality) for aluminium each 438.30
doors including necessary cutting and making good etc. complete.
25-125 Providing and fixing anodized aluminium (anodized transparent or dyed to required shade kg 298.80
according to IS: 1868. Minimum anodic coating of grade AC 15) sub frame work for
windows and ventilators a with extruded built up standard tubular sections of approved make
conforming to IS: 733 and IS : 1285 fixed with crawl plugs and stainless steel screws etc.

25-126 Providing and fixing aluminium casement windows fastener of required length for aluminium
windows with necessary screws etc. complete.

(a) Anodized (AC15) aluminium each 55.80


(b) Powder coated minimum thickness 50 micron aluminium. each 58.50
(c ) Polyester powder coated minimum thickness 50 micron aluminium . each 63.90
25-127 Providing and fixing aluminium round shape handle of outer dia 100mm with SS screws etc.
Complete as per direction of Engineer-in-charge
(a) Anodized (AC15 ) aluminium each 66.60
(b) Powder coated minimum thickness 50 micron aluminium each 73.80
(c ) Polyester powder coated minimum thickness 50 micron aluminium . each 79.20
25-128 Providing and fixing anodised aluminium grill (anodised transparent or dyed to required Kg 369.00
shade according to IS: 1868 with minimum anodic coating of grade AC15) of approved
design/pattern, with approved standard section and fixed to the existing window frame with
C.P. brass/ stainless steel screws @ 200mm centre to centre, including cutting the grill to
proper opening size for fixing and operation of handles and fixing approved anodised
aluminium standard section around the opening, all complete as per requirement and
direction of Engineer-in-charge. (Only weight of grill to be measured for payment).

25-129 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand sqm 4462.20
and manufacture, including providing and fixing top bottom pivot spring type fixing
arrangement and making necessary holes etc. for fixing required door fittings, all complete as
per direction of Engineer-incharge (Door handle, lock and stopper etc.to be paid separately).

25-130 Providing and fixing 50 micron thick reflective one way type heat /light control film to sqm 403.20
window/door glazing as marketed under the brand name garware/3M or equivalent as
approved.
25-131 Providing and fixing 50 micron thick Frosted heat /light control film to window/door glazing sqm 466.20
as marketed under the brand name garware/3M or equivalent as approved.
25-132 Providing and fixing 25 micron thick Non reflective heat /light control film to window/door sqm 316.80
glazing as marketed under the brand name garware/3M or equivalent as approved.
Page 124 of 132
Code Description Unit Rate
Water Proofing Work
25-133 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by sqm 186.30
applying cement slurry mixed with water proofing cement compound consisting of applying :

a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement
compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours.
b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement
compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with
water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of
all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

25-134 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry sqm 304.20
mixed with water proofing cement compound consisting of applying (a) after surface
preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing
cement compound @ 0.253 kg/sqm. b) laying second layer of Fibre glass cloth when the first
layer is still green.Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third
layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water
proofing cement compound @ 0.670 kg/sqm and sand @ 1.289 kg/sqm. This will be allowed
to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be
taken upto 30cm on parapet wall and tucked into groove in parapet all around.

Landscaping and Horticulture


25-135 Supplying and stacking of good earth at site including royalty if any and carriage (earth cum 511.20
measured in stacks will be reduced by 20% for payment).

25-136 Supplying and stacking sludge at site including royalty and carriage (sludge measured in cum 643.50
stacks will be reduced by 8% for payment).
25-137 Spreading of sludge, dump manure and/or good earth in required thickness as per direction of cum 16.20
officer incharge (Cost of sludge, dump manure or/ and good earth to be paid separately).

25-138 Mixing earth and sludge or manure in the required proportion specified or directed by the cum 10.80
officer incharge.
25-139 Grassing with selected type of grass including watering and maintenance of the lawn for 30 100sqm
days or more till the grass forms a thick lawn, free from weeds and fit for mowing including
supplying good earth, if needed (the good earth shall be paid for separately):

(a) In rows 15 cm apart in either direction. 100 sqm 1163.70


(b) In rows 7.5 cm apart in either direction 100 sqm 2404.80
(c) In rows 5 cm apart in both directions. 100 sqm 3601.80
(d) With grass Turf. 100 sqm 2856.60
25-140 Uprooting rank vegetation and weeds by digging the area to a depth of 60cm removing all 100 sqm 1861.20
weeds and other growth with roots by forking repeatedly, breaking clods, rough dressing,
flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for
planting new grass, including disposal of all rubbish with all leads and lifts.

25-141 Preparation of beds for hedging and shrubbery by excavating further 30cm deep of allready cum 67.50
prepared trench, refilling the excavated earth after breaking clods and mixing with sludge
or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one
part of stacked volume of sludge or manure after reduction by 8%), flooding with water,
filling with earth if necessary, watering and finally fine dressing, leveling etc.including
stacking and disposal of materials declared unserviceable and surplus earth by spreading and
leveling as directed, within a lead of 50m lift up to 1.5 m complete (cost of sludge, manure or
extra earth to be paid for separately).
Page 125 of 132
Code Description Unit Rate
25-142 Providing and fixing M. S. tree guard 50 cm square in plan, height 1.40 metre above ground each 2244.60
level and 0.50 metre below ground level. The vertical members shall consist of four nos. of
angle iron of size 25x25x5 mm 1.9 long, one at each corner and 8 nos. flat iron of size 25x5
mm 1.4 long. The vertical members shall be welded to 4 nos. 25x6 mm M. S. flats placed
horizontally around the vertical member of the cage. One name plate of 1 mm thick M.S.
sheet of size 250x100 mm shall be welded to the tree guard near the middle height and
lettered PWD/ any other approved name. The tree guard shall be fixed to the ground by
making suitable holes and by embedding four corners leg in the ground , including refilling
the earth, compaction etc. complete. The tree guard shall be painted with two coats of paint
of approved brand and manufacture over a coat of primer, complete in all respect.

Plain Cement Concrete


25-143 Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as cum
per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 sand)
including the cost of required centering,shuttering andfinishing smooth with 6mm thick
cement plaster 1:3 (1 cement : 3 fine sand) on exposed surfaces complete.
(a) M15 (With 20mm nominal size graded stone aggregate) 4231.80

25-144 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions
etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and
the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic
item) :

(a) With float glass panes of 4.0 mm thickness sqm 764.10

(b) With float glass panes of 5.50 mm thickness sqm 838.80

(c) With float glass panes of 8 mm thickness sqm 1162.80

SECTION-B (WRD)
25-145 Providing and fixing 25 mm dia. 3 m long cold twisted deformed steel dowel bars with one each 868.00
end driven into 38 mm diameter 1.50 m deep hole drilled in bed rock and other end provided
with L- bend for embedding in concrete / masonry of over flow / non-over flow blocks and
other appurtenant works including cost of all materials, machinery, labour, drilling and
cleaning hole, filling hole with specified cement mortar, driving anchor rod etc. Complete.

25-146 Drilling 35 to 40 mm diameter grout holesin concrete / rock by percussion drilling using jack mt 327.00

25-147 Providing and fixing fine chisel dressed canal bed grade stone (Type design 5) embedding 45
cm depth of stone with 15 cm concrete all around & in bottom in cement concrete M-7.5
(Nominal Mix), grade including excavation (all type of soil) orientation of stone along centre
line and top of concrete is flushed with design bed level, curing etc. Complete. Using graded
aggregate of maximum size 40 mm.

(a) Size 60 x15 x15 cm each 343.00


(b) Size 55x15x15 cm 314.00 each 314.00
( c) Size 50x15x15 cm each 286.00 each 286.00
Page 126 of 132
Code Description Unit Rate
SECTION-C (MPRRDA)
25-148 Construction of Embankment with Material Obtained from Roadway Cutting

(a) Construction of embankment Cum 65.70


with approved materials
deposited at site from roadway
cutting and excavation from
drain and foundation of other
(b) Deduct if static roller is used in Cum 5.40
(c ) Deduct if motor grader is not Cum 6.30
used.
(d) Deduct if Tractor Mount Grader, Cum 2.70
more than 65 HP (6 wheel - 4
25-149 Excavation, Carting i/c Removal of Soil with Disposal upto 1000 m Cum 38.70
Excavation of embankment, sub-grade and drain consisting of excavation, removal and
satisfactory disposal of all excavated materials including hauling to sides of embankment and
subgrade construction as also the disposal of materials in specified manner and the trimming
and finishing of the road to the specified dimensions i/c all lifts, lead upto 1000 meters
including dewatering, shaping and excavation in marsh and complete disposal of all muck as
per clause 302. for all types of soil i/c moorum gravel etc. as directed by the Engineer-in-
charge

25-150 WBM Grading 2


Providing, laying, spreading and compacting stone aggregates of specific sizes to water cum 1410.00
bound macadam specification including spreading in uniform thickness, hand packing,
rolling with three wheel 80-100 kN static roller in stages to proper grade and camber,
applying and brooming, crushable screening to fill-up the interstices of coarse aggregate,
watering and compacting to the required density Grading 2 as per Technical Specification
Clause 405.
25-151 WBM Grading 3
Providing, laying, spreading and compacting stone aggregates of specific sizes to water cum 1527.00
bound macadam specification including spreading in uniform thickness, hand packing,
rolling with three wheel 80-100 kN static roller in stages to proper grade and camber,
applying and brooming, crushable screening to fill-up the interstices of coarse aggregate,
watering and compacting to the required density Grading 3 as per Technical Specification
Clause 405. (To be executed with prior written permision of CGM in unavoidable situations)
Page 127 of 132

Code Description Unit Rate

25-152 Construction of BGSY information board in cement concrete:- Each 8172.70


Construction of BGSY information board in cement concrete M-15
with skin reinforcement of 8 mm dia bars @ 300 mm C/C spacing in
both ways, including excavation, base concrete (M10), priming,
painting with two coats synthetic enamel paint on new concrete
surface including painting-figuring Logo and Slogan including
writing of all information about the road as per prescribed drawing.
25-153 Setting out work (Reference pillars, referencing bench mark and KM 9471.09
temporary bench mark):-
Construction of Reference Bench Mark 50x50x70 cm. made of 1:3:6
cement concrete i/c excavation of 50x50x50 cm pit, working
benchmark 30x30x45 cm at every 500 m interval made of 1:3:6
cement concrete i/c excavation of 30x30x30 cm pit and providing
and fixing of Reference pillars made of cast in situ or pre cast RCC
pole,1.50m long having dimensions as100x100mm at top and
150x150mm at bottom with 4 no. 8mm dia. bars in longitudinal
direction and 6mm dia. stirrups at 300mm c/c spacing - made in
cement concrete M-15, or finished stone posts 1500 x200x75 mm
size embedded in 30x30x45 cm cement concrete 1:3:6 i/c excavation
and casting etc. complete, @ 100 m interval or as required on both
sides of the formation width preferably at 5.50 m distance from
centre line.
25-154 Surveying, levelling, recording of levels & bearing, plotting and KM 5148.46
computation of quantity of earth work:-
Taking and recording of pre commencement levels and chaining as
per prescribed spacing i.e. 0.75, 1.5, 2.25, 3.00, 4.50, 5.50, 6.50 m in
both side across the road and at centre line, @ 20 m interval, taking
& recording bearing by magnetic compass surveying of centre line,
computation of levels and marking of Road Top Level(RTL) in L-
section & computation of volume for different components of road
accordingly, as per design and drawing, Setting out of Cross
Drainage structures with required reference pillars, Marking and
recording of levels on reference pillars by Green, Yellow and Red
synthetic emulsion paint for embankment, sub-grade, and RTL
respectively etc complete as directed by engineer- in-charge.
25-155 Printing New Letters and Figures of any Shade
Printing new letter and figures of any shade with synthetic enamel
paint black or any other approved colour to give an even shade as
per drawings and Technical Specification Clause 1701
(i) Hindi (Matras commas and the like not to be measured and per cm 1.04
paid for. Half letters shall be counted as half only) height
per letter

(ii) English and Roman per cm 0.64


height
per letter
25-156 Cautionary, mandatory, informatory, direction and place
identification signs
(i) Semi-Reflective Traffic signs more than 0.90 sqm size board
Page 128 of 132

Code Description Unit Rate

Providing and erecting cautionary, mandatory, informatory, sqm 5349


direction and place identification of semi reflective sign boards
as per IRC-67 made of 2 mm thick M.S. Sheet duly stove
enameled paint white colour in front and grey colour on back
with reflective border of 70 mm width and required message,
letters, figures with reflective tape of engineering grade as per
MORD specifications of required shade and colour. Supported
and welded on two nos. 47 mm x 47 mm of 12 SWG square
tube of 3050 mm height duly strengthened by 25 mm x 5 mm
MS flat iron on edges on back firmly fixed to the ground by
means of properly designed foundations with M-15 grade
cement concrete 450 mm x 450 mm x 600 mm, 600 mm below
ground level as per approved drawing and Technical
Specification Clause 1701
(ii) Semi-Reflective Traffic signs up to 0.90 sqm size board
Providing and erecting cautionary, mandatory, informatory,
direction and place identification of semi reflective sign boards
as per IRC-67 made of 2 mm thick M.S. Sheet duly stove
enameled paint white colour in front and grey colour on back
with reflective border of 70 mm width and required message,
letters, figures with reflective tape of engineering grade as per
MORD specifications of required shade and colour. Supported
and welded on 47 mm x 47 mm of 12 SWG square tube of
3050 mm height duly strengthened by 25 mm x 5 mm MS flat
iron on edges on back firmly fixed to the ground by means of
properly designed foundations with M-15 grade cement
concrete 450 mm x 450 mm x 600 mm, 600 mm below ground
level as per approved drawing and Technical Specification
Clause 1701

A 900 mm equilateral triangle Each 3188


B 600 mm Circular Each 3027
C 800 mm x 600 mm rectangular Each 3500
D 600 mm x 450 mm rectangular Each 2996
E 600 mm equilateral triangle Each 2722
25-157 Painting Two Coats on New Concrete Surfaces
Painting two coats including primer coat after filling the surface sqm 109
with synthetic enamel paint in all shades on new, plastered /
concrete surfaces as per drawing and Technical Specification Clause
1701
25-158 Kilometre Stone
Reinforced cement concrete M15 grade kilometre stone/local stone
of standard design as per IRC:8 fixing in position including painting
and printing, etc as per drawing and Technical Specification Clause
1703
(A) With Reinforced cement concrete
(i) 5th Kilometre Stone (pre cast) Each 3273
(ii) Ordinary Kilometer Stone (Pre cast) Each 1926
(iii) 200 m stone (precast) Each 519
(B) With Local Stone
(i) 5th Kilometre Stone Each 1923
(ii) Ordinary Kilometer Stone Each 982
Page 129 of 132

Code Description Unit Rate

(iii) 200 m stone Each 323


25-159 Tubular Steel Railing on Medium Weight Steel Channel (ISMC
series) 100mmx50mm
Providing, fixing and erecting 50 mm dia steel pipe railing in 3 rows R / Mt 1993
duly painted on medium weight steel channels (ISMC series) 100
mm x 50 mm, 1.2 m high above ground, 2 m centre-to-centre,
complete as per approved drawings Clause 1706
25-160 Tubular Steel Railing on Pre cast RCC posts, 1.2 m high above
Ground Level
Providing, fencing and erecting 50 mm dia painted steel pipe railing R / Mt 1722
in 3 rows on pre cast M-20 grade RCC vertical posts 175 mm x 175
mm x 1.8 m high (1.2 m above Gl) with 3 holes 50 mm dia for pipe,
fixed 2 m centre-to- centre complete as per approved drawings
Clause 1706
25-161 BGSY Sign Board
Providing and fixing of typical BGSY informatory sign board with Each 8726.9
Logo painting as per approved drawing. Three MS Plates of 1.6 mm
thick, top and middle plate duly welded with MS flat iron 25mm x
5m size on back on edges. The lower plate will be welded with MS
angle iron frame of 25mm x 25mm x 5mm. The angle iron frame of
the lower most plate and flat iron frame of middle plate will be
welded to 2 nos. 75mm x 75 mm of 12 SWG sheet tubes posts duly
embedded in cement concrete M-15 grade blocks of 450mm x
450mm x 600mm, 600mm below ground level. All M.S. will be
stove enameled on both sides. Lettering and printing arrows, border
etc. will be painted with ready mixed synthetic enamel paint of
superior quality in required shade and colour. All sections of
framed posts and steel tube will be painted with primer and two
coats of epoxy paint.
25-162 Guard stones
Providing and fixing guard stones on curves or at any other place as Each 453
directed by engineer in charge made of 220 X220X1000 mm
hammer dressed stones and fixed 400mm into the ground in
moorum and broken aggregates block of size 500X500X500mm and
painted with white and black bands in 2 coat including excavation of
pit etc. complete.
25-163 Providing and fixing circular type tree guard’s made of 10mm of Each 2235
size square bars of 1500mm height, 6 No. vertical out of which 3
fixed with hold fast for fastening in concrete and 3 No circular rings
to make tree guard of 1000 mm dia and 1500 mm high including
welded mesh with 18 gauge with 25 x 25 mm i/c fixing in ground
with CC (M-10) including excavation of pits welding, coating of red
oxide primer and painting with enamel paint etc. complete.
25-164 Tree Plantation including cost of tree and labours & as directed by Each 49
Engineer in Charge

25-165 BGSY Logo Board


Providing and fixing Logo Board of BGSY size 600×600mm each 3830
diamond shape with 1 plate of size 900×250 mm made of 16 gauge
sheet over frame of angle iron 25×25×3 mm, supported and welded
on 47×47mm square tube of 12 SWG sheet tubes of 2.90m long
high post duly strengthened by 25mm×5mm MS flat iron on edges
Page 130 of 132

Code Description Unit Rate

on back, firmly fixed to the ground by means of properly designed


foundation with cement concrete M-15 grade of
450mm×450mm×600mm, 600mm below ground level, all sections
of frames, posts and steel painted with ready mixed synthetic enamel
paint of superior quality in required shade and colour, as per
approved drawing.
25-166 Providing PCC M20 Architectural Coping on the top of wing wall, RM 282
return wall etc. complete as per drawing and technical specification
Clause 615 (400mm wide and 150 mm thickness)
25-167 Painting on Steel Surfaces
Providing and applying two coats of ready mix paint including sqm 97
primer coat of approved brand on steel surface after through
cleaning of surface to give an even shade as per drawing and
Technical Specification Clause 1701
25-168 Painting on Concrete/Steel Surfaces with Epoxy
Painting two coats including prime coat with epoxy paint of sqm 118
approved brand on concrete/steel surfaces after through cleaning of
surface to give an even shade as per drawing and Technical
Specification Clause 1701
25-169 Anchor bar for RCC slabs of submersible bridges
Providing and fixing 20mm dia MS anchor bar duly welded at
bottom with MS plate of size 500mm x 75mm x 10mm including all
material labour charges etc. as per plate no. 7.22 of SP-20 or
otherwise as directed by Engineer in Charge.
A) Fixed end anchor bar each 425
B) Free end anchor bar each 861
25-170 Providing and fixing in position bituminous paper bearing for slabs sqm 41
as per approved drawing and confirming to IS:1398
25-171 Providing and fixing in position anchor bar / dowel bar in 0.90 mtr. per bar 759.89
deep 65 mm dia drill hole with 25mm dia MS bar, 0.90 mtr. in hole
and 0.90 mtr above hole including placing, fixing of bar, grouting of
hole with 1:3 cement mortar including cost of all T&P, cost of air
and water, drilling of hole curing etc. complete.

25-172 Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 RM 2222


mm nominal size aggregate, true to line and grade, tolerance of
vertical railing post not to exceed 1 in 500, centre-to-centre spacing
between vertical posts not to exceed 2000 mm as per drawing and
technical specifications Clauses 800, 900 and 1208.3
25-173 Providing and fixing in position pipe railing consisting of IS Rolled RM 1945
steel joist posts designation IS MB 100 (100x75) at 2.5 m interval
and three rows of 50 mm dia steel pipes (light) including fixing in
position on bridge deck complete as per drawing and technical
specifications Clause 1208.2
25-174 Drainage spouts complete as per drawing and technical Nos. 1329
specifications Clause 1209
25-175 Providing weep holes in brick masonry/stone masonry, Rmt. 149
plain/reinforced concrete abutment, wing wall, return wall with 100
mm dia AC pipe extending through the full width of the structures
with slope of 1(V):20(H) towards drawing face complete as per
drawing and technical specification Clauses 614, 709, 1204.3.7
25-176 Filler Joint
Page 131 of 132

Code Description Unit Rate

I Providing and fixing 2 mm thick corrugated copper plate in RM 3240


expansion joint as per drawing and technical specifications
Clause 1207.2.2
II Providing and fixing 25 mm thick compressible fibre board in sqm 674
expansion joint complete as per drawing and technical
specifications
III Providing and fixing 20 mm thick compressible fibre board in sqm 570
expansion joint complete as per drawing and technical
specifications
IV Providing and fixing in position 25 mm thick pre moulded RM 168
joint filler in expansion joint for fixed ends of simply
supported spans, covered with sealant complete as per drawing
and technical specifications
V Providing and filling joint in CC pavement as per IS 3873/
IRC specification 100x10 recess to be filled with coarse sand
with bitumen (6.0% by weight) sealing compound as per
drawings and technical specifications with coarse sand and 6
per cent bitumen by weight.
A For joint size 6mmx70mm RM 36
B For joint size 5mmx70mm RM 21
25-177 Providing and laying boulder apron for bed protection with stone cum 886
boulders of minimum size and weight as per Table 1300.1, no
fragment weighing less than 25 kg laid dry complete as per drawing
and technical specifications Clause 1301
25-178 Providing and laying pitching on slopes laid over prepared filter
media as per drawing and technical specifications Clause 1302
Stone/Boulder cum 886
25-179 Providing and laying filter material underneath pitching in slopes cum 1326
complete as per drawing and technical specifications Clause 1302
25-180 Providing and laying of boulder apron laid in wire crates with 4 mm cum 1626
dia GI wire conforming to IS:280 and IS:4826 in 100 mm x 100 mm
mesh (woven diagonally) including 10 per cent extra for laps and
joints laid with stone boulders weighing not less than 25 kg each as
per drawing and technical specifications Clause 1301 i/c gabions
25-181 Providing and laying of dry rubble flooring complete as per cum 1235
drawings and technical specifications Clause 1303.3
25-182 Construction of boulder/stone masonry wall as per drawing and cum 1026
specifications in mud mortar or dry including white washing 3 coats
to one side of the wall for guard walls, temporary diversion etc.
including all materials, labour complete.
25-183 Providing and laying filter media with granular crushed aggregates cum 995
as per specification to a thickness of not less than 600 mm with
smaller size towards the soil and bigger size towards the wall and
providing over the entire surface behind abutment, wing wall, return
wall to the full height, compacted to firm condition complete as per
drawing and technical specification Clause 1204.3.8

25-184 Supplying, fitting and fixing in position true to line and level cucm 0.51
elastomeric bearing conforming to IRC:83 (Part-II) Section IX
complete, including all accessories as per drawings and technical
specification Clause 1207.1
25-185 Providing pressure relief pipes 100 mm dia in bottom slab of box Nos. 466
Page 132 of 132

Code Description Unit Rate

cell on a filter media base of 500 mm x 500 mm as per drawing and


technical specification Clause 1205.5.7
APPENDIX-A
APPENDIX-B
APPENDIX-C
APPENDIX-D
APPENDIX-E
APPENDIX-F
APPENDIX-G