MASTERTOP® 1210

Epoxy resin based, industrial floor coating

DESCRIPTION PROPERTIES
MASTERTOP 1210 is a seamless floor coating based a. Components
on advanced solvent free epoxy resin system. The cured Form Colour Density
coating provides a glossy, easily cleaned and hygienic
surface with excellent resistance to mechanical wear A1 Liquid Milky 1.5 kg/L
and chemical attack. Slip resistance can be imparted to X1 Paste Coloured 1.85 kg/L
the treated surface using selected aggregates.
MASTERTOP 1210 is one of the floors available from B1 Liquid Amber 1.05 kg/L
the Polykit system.
b. Mixed system
Components : A1:B1:X1
The Polykit system consists of a limited number of
standardised components which allows production of a Mix ratio (by weight) : 9.4:3.0:0.6
wide range of epoxy resin floors for different applications Density : 1.37 kg/L
in a variety of colours.
Colour : Refer colour card
RECOMMENDED FOR Pot life @ 20°C : 45 mins.

MASTERTOP 1210 is recommended for floors where an Trafficable time (full traffic load):
attractive, easily cleaned coating is desired and where @ 10°C @ 20°C @ 30°C
mechanical abrasion and chemical spillage could pose
risk of floor damage. It is ideal for floors in; 5 -7 days 3 - 4 days 2 - 3 days
• storerooms.
• oil-pits and sumps. APPLICATION
• corridors and stairways.
MASTERTOP 1210 normally does not require a primer
FEATURES AND BENEFITS and is a two coat treatment on the prepared substrate.
Depending on the condition of the substrate a priming
Solvent free Safety during application. coat may become necessary, and with an optional anti
slip finish it can be a three layered treatment consisting
Impervious, seamless Allows floor surface to be
of a. Priming Coat, b. 2 Body Coats and c. Top Coat.
and jointless. maintained in a hygienic state.
Pre proportioned. Avoids batching errors. Surface preparation
Ensure that the compressive strength of floor concrete is
Wide colour range. Attractive floors. Pleasant
at least 25 N/mm2 and that concrete slabs directly in
working environment.
contact with the ground have a proper vapour barrier
Chemical resistant. Lower maintenance costs. installed as per DIN 18195 or an equivalent standard.
Protects concrete from Correct substrate preparation is critical for optimum
chemical attack. performance. Surfaces should be structurally sound,
clean, and free from loose particles, oil, grease, or any
PERFORMANCE DATA other contaminants.
Remove oil grease and wax contaminants by scrubbing
After 7 days cure @ 20°C
2 with industrial grade detergent or degreasing
Bond strength (ZTV SIB87) : ≥2.5 N/mm compounds followed by mechanical cleaning.
(concrete failure) Cement laitence, loose particles, mould release agent,
Abrasion resistance (DIN : 105 mg curing membrane, and other contaminants must be
53754 - Taber) removed and the surface roughened by shotblasting
(blastracking), scarifying or gritblasting followed by
Service temperature : -20°C to 60°C
vacuum cleaning.
Application Temperature -min. : 8°C Protect walls and columns against roller marks and resin
max. : 35°C splashes using masking tape and polythene sheeting.
Joints: Existing joints in the floor should be continued
through MASTERTOP 1210 system. Design the joint
dimension to allow for anticipated movements.

Head Office Factories Representative Offices


Plaza GRI 10th & 11th Floor Jl. Daan Mogot Km.14 Jl. Jababeka V Blok I-1 Grand Residence Office Park, Komp. Pertokoan Royal Sunggal
Jl. HR Rasuna Said Blok X-2 No.1 Cengkareng, Cikarang Industrial Estate 1st Floor Jl. Gagak Hitam No. A-12
Jakarta 12950 Jakarta 11750 Bekasi 17530 Jl. Darmo Harapan Complex 1 Ring Road – Sunggal
Tel.: (6221) 5262481, 5262505 Tel.: (6221) 6190007 Tel.: (6221) 8934339 Surabaya 60187 Medan, Sumatera Utara 20128
Fax: (6221) 5262493, 5262515 Fax: (6221) 6190741 Fax: (6221) 8934342 Tel.: (6231) 7326705 Tel.: (6261) 8447110
Fax: (6231) 7326730 Fax: (6261) 8444072
MASTERTOP® 1210
a. Priming Coat (where necessary) ESTIMATING DATA
Apply Mastertop 1140 (see separate data sheet) as a
primer if the surface is either damp, very dense or where The consumption of both the primer and body coat
occurrence of pin holes is unacceptable. depends on absorption of the substrate, floor profile,
thickness of coating and wastage.
b. Body Coat
On a dense, flat surface typical consumption will be as
Mixing below.
Use a slow speed (600 rpm) electric drill fitted with a
2
wing type mixing paddle (refer Tools data sheet). Ensure Primer Mastertop 1140 0.25 kg/m
that the container of each component is completely 2
emptied while mixing. Body Coats MASTERTOP 1210 0.68 kg/m
Thoroughly stir one unit of A1 resin, then add one 0.5 mm in 2 coats
cartridge of X1 colour pack and mix until the colour Top Coat Filler F5 50 g/m
2

pigment is evenly dispersed. Add one unit of B1 2


hardener and mix for 3 minutes until a homogeneous Sealer coat of 0.3 kg/m
mix is obtained. MASTERTOP 1210
Mixing of large batches (in multiples of the above kits)
may be done in a forced action mixer. PACKAGING
Note: To ensure a uniform colour shade on an area of
continuous treated surface, only use X1 paste cartridges The various components of MASTERTOP 1210 are
with identical batch numbers. available in the following packaging.
Placing
Component Description Packaging
If the floor is primed, the mixed material should be
placed between 8 and 24 hrs after the application of A1 Resin 9.4 kg pail
primer.
Apply the mixed coating onto the prepared floor using a B1 Standard hardener 3.0 kg can
brush or a short napped mohair roller at a rate of not X1 Coloured additive 0.6 kg cartridge
less than 0.3 kg/m2 per coat. At least two coats must be
applied, with the second coat applied 10 to 24 hours F5 Filler 25 kg bag
after the first coat and at right angles to it. The final
thickness of the body coat should be approximately 0.5
mm. STORAGE
c. Top Coat Store components in a dry enclosed place without
If an anti slip surface is desired, broadcast F5 filler at a exposing to direct sunlight at temperatures between
rate of approximately 50 g/m2, when the second body 15°C and 40°C.T
coat is still wet. Remove unbound filler after a day using
scrapers, brush or vacuum and apply a sealing coat. SHELF LIFE
Note : It is recommended that a small trial is done on a
12 months in original unopened packing if stored as
typical surface for approval of the finished surface
recommended.
texture.
PRECAUTIONS
CURING
Health : MASTERTOP 1210 contains certain chemicals
MASTERTOP 1210 is self curing. The curing time
which can cause skin irritation if exposed and respiratory
depends on the ambient temperature, and the quantity
reaction if inhaled. Wear gloves, masks and use barrier
mixed and placed. Under normal circumstances initial
creams such as Kerodex No. 71 while handling the
curing will take place overnight.
product. Wash thoroughly after handling.
The coating will be fully cured in 7 days.
Should skin contact occur wash immediately with soap
MASTERTOP 1210 must be suitably protected for at
and water, or an effective hand cleaner.
least 24 hours after laying from following trades, spillage,
In case of accidental eye contact wash with copious
dust, insects, small animals, traffic, moisture, etc.
quantities of water and seek medical help immediately.
CLEANING If ingested, do not induce vomiting. Consult doctor
immediately.
Clean the tools and equipment first with rags, then wipe The vapours of solvents used for cleaning can be
off using a solvent such as acetone, or irritating . It is therefore recommended that cleaning is
methylisobutylketone before the resin system hardens. done in well ventilated areas.
Fire : Keep away from sources of ignition. Do not smoke
while handling the product.
MASTERTOP® 1210
OTHERS USEFUL PRODUCTS
12 months in original unopened packing if stored as
Mastertop : A range of industrial flooring products that
includes resin based floor screeds and coatings, dry
shake iron aggregate based floor hardeners and iron
aggregate based floor screed.
Barra repair system : Includes corrosion protective
coating for steel, polymer bonding agents, and Barra
range of polymer modified repair mortars for; anchoring,
surface leveling, high build in vertical and over head
situations.
Emaco : A range of high performance structural repair
mortars available in pourable, pumpable and sprayable
grades, for high build (up to 120 mm) and medium build
(up to 40 mm) applications.
Concresive : Resin based mortars for chemical
resistance and exceptional strengths.
SMt 1210/02/0998

The technical information and application advice given in this BASF Construction Chemicals
publication are based on the present state of our best scientific and practical knowledge. As the
STATEMENT OF information herein is of a general nature, no assumption can be made as to a product's suitability for a
RESPONSIBILITY particular use or application and no warranty as to its accuracy, reliability or completeness either
expressed or implied is given other than those required by law. The user is responsible for checking the
suitability of products for their intended use.
Field service where provided does not constitute supervisory responsibility. Suggestions made by
BASF Construction Chemicals either orally or in writing may be followed, modified or rejected by the
NOTE owner, engineer or contractor since they, and not BASF Construction Chemicals, are responsible for
carrying out procedures appropriate to a specific application.