ORACLE DATA SHEET

ORACLE TYPE-A Energy Storage Module ESM


Energy Storage Module Overview
The Sun Flash Accelerator F20 PCIe card includes an energy storage module (ESM) to
ensure data integrity during a power interruption, functioning similar to a battery backup.

Data indexing and data cache are periodically stored on volatile memory on each
FMOD. The data cache is necessary to achieve the performance expected of the
FMODs. In the event of a power interruption, existing data in volatile storage must be
written to flash memory before total power loss occurs. When properly charged and in
service, the ESM provides enough electrical power to enable data to be written to local
flash memory during a sudden power loss. The ESM is essential for protecting the
FMODs from damage and for ensuring data integrity.

Note - If the ESM is offline or charging, the FMODs function in write-through mode
(writing all data directly to flash memory), resulting in significantly
reduced write performance. If you see a significant decrease in write performance,
make sure the ESM is functioning properly.

Caution - Long-term ESM durability is affected by excessive heat. As with all data
center equipment, maintaining efficient system and component cooling is critical. For
more specific site planning guidelines and best practices, refer to your server site planning
guide and product notes.
ORACLE DATA SHEET

Each Controller has one ESM for every NVDIMM. ESMs are located inside the
Controller's ESM drive compartment. An Oracle Flash Storage System with a basic
configuration contains two ESMs and two NVDIMMs An Oracle FS System configured
for performance contains four ESMs and four NVDIMMS ESMs are customer
replaceable units (CRUs) The following figure shows the location of the ESM modules.
ORACLE DATA SHEET

Important: Do not mix ESM and NVDIMM types. ESM type must match the NVDIMM type. For
example, an ESM labeled A (ESM-A) must be paired with an NVDIMM labeled A (NVDIMM-A);
The NVDIMM type is printed on a small label near the end of the NVDIMM cable. Note: To
replace an ESM, you do not need to remove the Controller from the rack or even extend it
along the Controller rails. Note: Make a note of the ESM slot where the failed ESM was located
so that the replacement ESM can be placed in the same slot to avoid the risk of
misconfiguration alternatively replace the ESMs only one at a time so that there is only one
empty ESM slot at any point in time.