Sei sulla pagina 1di 21

A Systems Solution to

Waterproofing

1
STATE-OF-THE-ART
MANUFACTURING
AND R&D

We develop most of our products


in-house with the help of a strong,
research-driven innovation led with
consumer insights. All the products
are manufactured under ISO
9000 certification. Our R&D team
works closely with the marketing
and technical service teams to
COMPANY develop and enhance products that
PROFILE
meet the continuously changing
Pidilite Industries has been Pidilite has some of the biggest requirements of our customers.
the pioneer and market leader brands in adhesives and sealants
in adhesives and sealants, category. These brands include Innovation being one of the core
construction chemicals, art and Fevicol, M-seal and Fevikwik. Fevicol values of the company, Pidilite
craft products and polymer has become synonymous with has established a state-of-the-art
emulsions in India. Pidilite started adhesives to millions in India and is research centre in Singapore to
in 1959 manufacturing only ranked amongst the most trusted expand the company’s product
white glue – Fevicol, and has brands in the country. Some of our innovation strategy and attract
now grown to cater to various other major brands are Dr. Fixit, international talent to work on
other categories including paint Pagel and Roff in construction in-house global brands. This
chemicals, automotive chemicals, chemicals, Cyclo and Motomax in Pidilite Innovation Centre, is now
art materials and stationery, fabric auto care, Ranipal in fabric care, a member of Singapore Chemical
care, maintenance chemicals, Fevistik glue stick and Hobby Ideas Industry Council (SCIC).
industrial adhesives, industrial and which is a Do-It-Yourself range of
textile resins and organic pigment hobby and craft products.
preparations. Most of the products
have been developed through our
strong in-house R&D.

3
Pidilite manufactures and available all across India and at our Waterproofing is a process that is Here’s where Dr. Fixit can help
CONSTRUCTION markets a wide range of global subsidiaries in Middle East, STATE-OF-THE-ART designed to prevent water from you get the best waterproofing
CHEMICALS DIVISION construction chemical products Thailand, Singapore and Brazil. WATERPROOFING penetrating a structure. Typically, solutions for your new constructions.
under two brands - Dr. Fixit & Our construction chemicals
SYSTEMS waterproofing is done in various Dr. Fixit is India’s leading brand
Roff covering different aspects of products are also available in layers and stages to create in waterproofing with a wide
construction like waterproofing, over 30 other countries. Pidilite multiple barriers so that water variety of products and solutions
building repairs, tile fixing, Industries Ltd. has promoted cannot penetrate the structure. to meet all your waterproofing
admixtures, sealants, flooring Dr. Fixit Institute of Structural A combination of such stages is needs - from foundations to walls
and grouts. Pidilite is the Protection and Rehabilitation (DFI- referred to as creating a “Building to roofs. With access to the latest
country’s leading player in the SPR), a standalone not-for-profit Envelope”. However, most often global technologies through its
retail market for construction organisation with a vision to become enough importance is not given international subsidiaries and R&D
chemicals with the Dr. Fixit and a premier national knowledge to this very crucial area while centres, Dr. Fixit constantly brings
Roff brands. Under Dr. Fixit, we and skill development centre in constructing new structures. innovative waterproofing solutions.
offer a range of waterproofing waterproofing and other areas of Over-reliance on conventional and Dr. Fixit also offers full technical
and repair solutions while Roff renewal engineering. The endeavour outdated systems, low awareness support with a large pool of trained
has a complete range of tile is to enhance the service life of Built about modern waterproofing applicators. Get in touch with us to
fixing solutions. Besides a large Environment through global sharing systems and lack of trained benefit from our state-of-the-art
and comprehensive product knowledge and best practices in the expertise for application are some waterproofing systems for your
range, Pidilite has also trained field of Waterproofing, Structural of the reasons for the same. new constructions.
and associated with a large Protection, Repair and Rehabilitation.
pool of applicators to offer the It has also set up an Advance
right advice and solutions to its Diagnostic Lab and library for
customers. Our products are industry professionals on its campus.

5
Page Areas of System Waterproofing
No. Application Code Systems

9 Basement LPW LIFT PITS WATERPROOFING

10 DBWP 15 DEEP BASEMENTS

12 DWP 15 DEEP WET BASEMENTS

14 SWB 10 SHALLOW WET BASEMENTS

16 SDB 10 SHALLOW DRY BASEMENTS

19 Terrace CRW 7 FLAT ROOF WITH SCREED

20 IPR 7 PITCHED SLOPING ROOF

22 EFR 5 EXPOSED FLAT ROOF - SINGLE APPLICATION

Contents 23 EFR 10 EXPOSED FLAT ROOF - DOUBLE APPLICATION

24 WPA WATERPROOFING ACCESSORIES

26 External Walls EWWP 5 EXTERNAL WALLS

28 Podium PWP 15 PODIUM WATERPROOFING

29 PWP 10 PODIUM WATERPROOFING

30 PWP 10 - PODIUM WATERPROOFING WITH


LSP LANDSCAPING AND SWIMMING POOL

33 Water Bodies WW 15 WET AREA WATERPROOFING

34 SWP 10 SWIMMING POOL - EXTERNAL SIDES

35 SWP 10 SWIMMING POOL - INTERNAL SIDES

36 GRWP 10 GROUNDWATER RESERVOIR

7
LIFT PITS
WATERPROOFING

Waterproofing for LIFT PITS


System Life Effective system to prevent leakage &
Expectancy: dampness in lift pits
Dr. Fixit SOLYSEAL 7 years

LPW 7
Methodology
surface PREPARATION Application

¬¬ Before applying the waterproofing ¬¬ Apply three coats of Dr. Fixit


membrane, clean the surface Solyseal to the inside area of the
for any debris, etc. Remove all lift pit to a total thickness of 2 mm.

Basement surface imperfections, protrusions,


structurally unsound and loose
concrete, and repair with polymer
Leave this to be air-cured.
¬¬ On the inside corners, over the
angle fillets, place a glass fibre
modified mortar using Dr. Fixit mesh measuring 2 mm x 2 mm
Pidicrete URP. as a reinforcement over the first
¬¬ Where separate concrete layers coat of Dr. Fixit Solyseal, while it
are poured at different levels, fill is still wet. Subsequently the next
and smoothen the gaps to obtain a two coats can be applied after the
comparatively smoother surface. previous coat is touch-dry.
When cleaning the substrate, ¬¬ Place a protection board of 4
remove any pollutants - such mm thickness to protect it from
as chemicals, curing agents, etc. - damages at the site and the
which may affect the installation of the lift car.
membrane adhesion.
¬¬ Angle fillets with a polymer
modified mortar of the
measurements 1 inch x 1 inch.

Dr. Fixit Pidicrete URP Dr. Fixit Solyseal


SBR latex for waterproofing and repairs Polymer modified elastomeric bituminous coating

9
DEEP BASEMENTS

Waterproofing in
HIGH Water Table Areas

Dr. Fixit Flexshield

DBWP 15
Methodology System Life High-performance basement waterproofing
Expectancy: system
SURFACE PREPARATION Construction of the Basement
15 years
Retaining Wall
¬¬ For horizontal application, concrete substrate before you
smoothen and level the new spread out the Dr. Fixit Flexshield Waterproofing for the external side
concrete layer. It should be left to membrane, to protect it from any of the retaining wall will also be taken
mature for at least 72 hours. protrusions. up with Dr. Fixit Flexshield. The
¬¬ Before laying the waterproofing ¬¬ In the horizontal areas, lay the application should be taken up from the
membrane, clean the waste off Dr. Fixit Flexshield membrane bottom-up.
the surface. Remove all surface loosely, between two layers of ¬¬ Begin the application of the
imperfections, protrusions, geotextile sheets. Dr. Fixit Flexshield membrane
structurally unsound and loose ¬¬ Bond the laps of the membrane from the bottom side, unrolling each
concrete, and repair with polymer sheets using a splice adhesive and membrane upwards to its maximum.
modified mortar using Dr. Fixit tape. The overlapping must be at Strap them up and fasten it with
Pidicrete URP. least 75 - 100 mm wide. Splicing must screws and washers.
¬¬ Where separate concrete layers be done after you prime the splicing ¬¬ Seam the lap joints. After each lift of
are poured at different levels, fill area. The splice tape is two-sided and the concrete wall is cast, continue with
and smoothen the gaps to obtain a is stuck over the primed part which the Dr. Fixit Flexshield membrane
comparatively smoother surface. adheres to the Dr. Fixit Flexshield in the manner explained in the above
When cleaning the substrate, membrane under it and over it, point. This will be continued to at least 1 PCC
remove any pollutants - such as securing the lap joint effectively. 6
1 metre above the ground level for 2 Dr. Fixit Flexshield
chemicals, curing agents, etc. - ¬¬ Over the Dr. Fixit Flexshield complete protection.
which may affect the membrane 3 Geotextile fabric
membrane comes the geotextile ¬¬ Bond the portion of the Dr. Fixit
5
adhesion. membrane of at least 150 gsm, 4 Screed
Flexshield membrane on the vertical 4
Installation of Dr. Fixit Flexshield and over that, lay a 50 – 75 mm side, which is in contact with the 5 Angle Fillet
3
Membrane for Raft Waterproofing protective concrete screed of M 20 membrane applied on the horizontal 6 Aluminium Flashing with
grade and cure it well for at least 7 side with an adhesive. Dr. Fixit Silicone Sealant
Whenever Dr. Fixit Flexshield days. Its purpose is to protect the 2
membrane is being installed, it is highly waterproofing membrane system ¬¬ Cast concrete over it to protect the
recommended to lay membrane at the from further damages that may joining of these membranes.
1
position and allow it to relax for at least occur during the installation of the ¬¬ Conduct spot bonding of a geotextile
45 minutes. This will help in releasing reinforcing steel, in-situ casting of the over the vertical Dr. Fixit Flexshield
the tensions in the membrane. raft concrete and / or vibrations, etc. membrane, followed by a protection
¬¬ The membrane should cover the PCC board of the specifier’s choice.
¬¬ Always lay a geotextile of 250 gsm
for protection of the waterproofing or blinding concrete well beyond the ¬¬ After this, carry out soil backfilling.
membrane, loosely laid on the perimeter of the area.

Dr. Fixit Pidicrete URP Dr. Fixit Flexshield


SBR latex for waterproofing and repairs EPDM based waterproofing membrane

11
DEEP WET BASEMENTS

Waterproofing in Fully Submerged


and Constrained Conditions

Dr. Fixit Flexshield


Dr. Fixit Extensa

DWP 15
Methodology System Life High performance deep and wet basement
Expectancy: waterproofing system
SURFACE PREPARATION
15 years
¬¬ For horizontal application, ¬¬ Bond the laps of the membrane ¬¬ Dr. Fixit Extensa is a fast-setting
smoothen and level the new sheets using a splice adhesive and water-based product which will
concrete layer. It should be left to tape. The overlapping must be at tenaciously adhere to concrete. It
mature for at least 72 hours. least 75 - 100 mm wide. Splicing is applied to form a seamless, high
¬¬ Before laying the waterproofing must be done after you prime the water-resistant membrane with an
membrane, clean the waste off splicing area. The splice tape is two- elongation of > 1000 %.
sided and is stuck over the primed
the surface. Remove all surface ¬¬ Protect Dr. Fixit Extensa with
imperfections, protrusions, part which adheres to the Flexshield
a geotextile sheet of 200 gsm at
structurally unsound and loose membrane under it and over it,
least, or with a protection board
concrete, and repair with polymer securing the lap joint effectively.
depending on what the site needs.
modified mortar using Dr. Fixit ¬¬ Over the Flexshield membrane Generally, a protection board can
Pidicrete URP. comes the geotextile membrane of be of highly compressible closed
¬¬ Where separate concrete layers at least 150 gsm, and over that, lay cell foam.
a 50 – 75 mm protective concrete
are poured at different levels, fill ¬¬ Begin soil backfilling after this
and smoothen the gaps to obtain a screed of M 20 grade. Cure it well
installation.
comparatively smoother surface. for at least 7 days. Its purpose
When cleaning the substrate, is to protect the waterproofing
1
remove any pollutants - such as membrane system from further Blinding Concrete

chemicals, curing agents, etc. - damages that may occur during the 2 Dr. Fixit Flexshield

which may affect the membrane installation of the reinforcing steel, 3 Dr. Fixit Extensa
adhesion. in-situ casting of the raft concrete
4 Shotcrete 6
and / or vibrations, etc. 5
5 Shoring
Installation of Dr. Fixit Flexshield ¬¬ The membrane should cover the 4
Membrane for Raft Waterproofing 6 RCC Retaining Wall
PCC or blinding concrete well beyond
¬¬ Always lay a geotextile of 250 gsm the perimeter of the area.
3
for protection of the waterproofing Waterproofing of the Retaining
membrane, loosely laid on the Wall – External Side
concrete substrate before you 2
spread out the Flexshield membrane, ¬¬ On the vertical side of the retaining
to protect it from any protrusions. wall, apply Dr. Fixit Extensa over
the concrete, at 2 mm thickness 1
¬¬ In the horizontal areas, lay the
Dr. Fixit Flexshield membrane with designated spray equipment,
loosely between two layers of in one application.
geotextile sheets.

Dr. Fixit Flexshield Dr. Fixit Pidicrete URP Dr. Fixit Extensa
EPDM based waterproofing membrane SBR latex for waterproofing and repairs Highly elastomeric and puncture resistant
waterproofing coating
13
SHALLOW WET
BASEMENTS

Waterproofing in Shallow
Water Table Areas

Dr. Fixit Torchshield SP 4160

SWB 10
Methodology System Life Robust tanking system for high-performance
Expectancy: basement waterproofing
SURFACE PREPARATION
10 years
¬¬ Clean the surface thoroughly to ¬¬ Now, lay the geotextile membrane of ¬¬ As the activity goes upward, carry
get rid of all contaminants like dust, 120 gsm as a protection layer over the out the application of Dr. Fixit
traces of curing compound, Torchshield membrane. Torchshield SP 4160 membrane,
oil and grease. ¬¬ Overlay a screed of 50 mm of M 20 along with the protection system,
¬¬ Remove all surface imperfections, concrete grade, which will facilitate a minimum of 300 mm above
protrusions, structurally unsound the reinforcement cage to be the ground level or as per the
and loose concrete, and repair with assembled, so the RCC raft can be finished floor level. Use a C-shaped
polymer modified mortar using cast over it. aluminium flashing strip or tuck it
Dr. Fixit Pidicrete URP. into the concrete wall of a groove
¬¬ Provide Dr. Fixit Waterbar - a of 12 mm x 12 mm. In case of the
Priming swellable, adhesive strip waterbar of groove, the aluminium flashing
20 mm x 20 mm - in the construction can be fitted to press the
¬¬ Conduct priming all over the joints, which is placed on the inside membrane into the groove and
blinding concrete or PCC of the reinforcement in both the raft then be filled with a single
(properly levelled) using Dr. Fixit concrete floor and the side retaining component Dr. Fixit PU Sealant.
Torchshield Primer. concrete walls..
¬¬ Do this with a roller or brush over a Application on Vertical Surfaces
ALTERNATIVELY
dried surface. Allow the primer to 1 PCC
Two layers of Dr. Fixit Samshield
dry for 8 to 10 hours. ¬¬ Over the RCC raft, the side retaining 2 Primer
membrane can be applied in place of 8
walls are cast in concrete. Prepare
Application on PCC below the Raft Dr. Fixit Torchshield SP 4160. 3 Dr. Fixit Torchshield SP4160 (2 layers) 6
the retaining wall surface to receive
Slab waterproofing system as detailed in 4 Geotextile
5
¬¬ Lay Dr. Fixit Torchshield SP 4160, the surface preparation above. 5 Screed
4
an SBS based polyester reinforced ¬¬ After the application of the primer 6 Dr. Fixit Waterbar SW2020
7 3
membrane by providing an overlap and drying it, lay two layers of 7 Angle Fillet
2
of at least 100 mm. Dr. Fixit Torchshield SP 4160.
8 Protection board
¬¬ Lay a second layer of the Dr. Fixit ¬¬ Place a bituminous protection
1
Torchshield SP 4160 membrane board of 4 mm thickness or a
with an overlap of 50% above the HDPE dimpled drain board of 12
first layer. mm thickness vertically over the
¬¬ Extend the membrane to the Torchshield membrane, allowing the
maximum extent of the full area of soil backfill.
the blinding concrete.

Dr. Fixit Pidicrete URP Dr. Fixit Torchshield Dr. Fixit Waterbar Dr. Fixit Samshield Dr. Fixit PU Sealant
SBR latex for waterproofing and repairs APP / SBS modified bitumen Flexible adhesive waterstop strip Self-adhesive bituminous membrane One-part non-sag polyurethane sealant
based membrane
15
SHALLOW DRY
BASEMENTS

Waterproofing in
Shallow Dry Basements

Dr. Fixit Samshield XL 1500 / 2100

SDB 10
Methodology System Life Protection from chemical contamination in soil
Expectancy: along with excellent waterproofing
SURFACE PREPARATION
10 years
¬¬ Clean the surface thoroughly to ¬¬ Provide a 50 mm selvedge on one ¬¬ Apply Dr. Fixit Samshield XL
get rid of all contaminants like dust, side of the membrane to give a 1500 / 2100 membrane starting
traces of curing compound, oil bitumen-to-bitumen contact on the with the sides of the raft and go
and grease. overlaps. right up to the top of the external
¬¬ Remove all surface imperfections, ¬¬ Lay a geotextile membrane of 120 wall face and stop there. Use a
protrusions, structurally unsound gsm as a protection layer over the C-shaped aluminium flashing strip
and loose concrete, and repair with Dr. Fixit Samshield XL 1500 / or tuck it into the concrete wall of a
polymer modified mortar using groove measuring 12 mm x 12 mm.
2100 membrane.
Dr. Fixit Pidicrete URP. ¬¬ In case of the groove, fit the
¬¬ Overlay a screed of 50 mm of M 20
aluminium flashing to press the
Priming concrete grade which will facilitate
membrane into the groove and then
the reinforcement cage to be
Apply Dr. Fixit Torchshield Primer to fill with a single component
assembled, for the RCC raft to be
a clean, smooth and dry surface using Dr. Fixit PU Sealant.
cast over it.
a brush or roller. Allow the primer to ¬¬ Place bituminous protection boards
dry prior to the application of the ¬¬ Provide Dr. Fixit Waterbar - a
over the Dr. Fixit Samshield XL
Dr. Fixit Samshield XL 1500 / 2100. swellable, adhesive strip waterbar
1500 / 2100 membrane before
of 20 mm x 20 mm - in the
backfilling. 1
PCC
Application on PCC below the Raft construction joints, which is placed
on the inside of the reinforcement 2 Dr. Fixit Torchshield Primer 7
Slab
in both the raft concrete floor and 3 Dr. Fixit Samshield XL 1500 / 2100 6
¬¬ Peel off the release film from the the side retaining concrete walls. 4 Geotextile Fabric 5
Dr. Fixit Samshield XL 1500 /
2100 self-adhesive side and start Application on Vertical Surfaces 5 Screed 4
unrolling the membrane while 6 Dr. Fixit Waterbar SW2020 3
pressing it to the surface. ¬¬ Make angle fillets all around
the corners of the raft and the 7 Protection Board
2
¬¬ Smoothen the membrane from retaining wall. Use polymer
the centre to the edges with a modified mortar prepared with
wooden press in order to remove 1
Dr. Fixit Pidicrete URP.
entrapped air.
¬¬ Take care to chamfer all the edges
¬¬ Use an iron roller for rolling on top of screed and raft slab to facilitate
of the applied membrane to ensure the membrane to move over it.
a proper and strong adhesion of the
bitumen compound with the base.

Dr. Fixit Pidicrete URP Dr. Fixit Samshield Dr. Fixit Waterbar Dr. Fixit PU Sealant
SBR latex for waterproofing and repairs Self-adhesive bituminous membrane Flexible adhesive waterstop strip One part non-sag polyurethane sealant

17
FLAT ROOF WITH
SCREED

Commercial Flat Roof


Easy-to-apply, elastomeric waterproofing
System Life
Expectancy: coating that can be applied over contours or
Dr. Fixit Roofseal 7 years projections in the roof

CRW 7
Methodology Methodology
SURFACE PREPARATION

¬¬ Provide slope in new construction ¬¬ Over the wet coat, place and press 1 Slab
while casting the roof slab (1 in 100 or down an open woven mesh of glass

fibre and allow it to soak completely. 2 Angle Fillet


1 in 80).

Terrace ¬¬ A thorough surface preparation is a


must over the entire roof area,
¬¬ Immediately, apply the second coat
of Dr. Fixit Roofseal to embed the
3 Primer
4 Dr. Fixit Roofseal (2 coats)
mesh in the coating. Allow it to dry 5 Geotextile
¬¬ Provide angle fillets in cement-
completely.
sand-mortar admixed with Dr. Fixit 6 Screed
Pidicrete URP, measuring 50 mm x ¬¬ After 48 - 72 hours, place a loosely laid 7 Drip mould
50 mm all along the junction of the geotextile fabric of at least 100 gsm
parapet wall and the roof slab. with 30 cm overlaps.
¬¬ Wrap any pipe inserts or protrusions ¬¬ Over the geotextile fabric, lay 50 mm
in the slab with Dr. Fixit Bathseal thick levelled screed of M 20 grade.
Tape. ¬¬ Screed can be cast in alternate bays’
¬¬ Grout around the pipe before method. Cut wooden battens of 12
initiating the task of waterproofing. mm thickness to size, according to the
slope and fix them on the roof surface
Priming
with the help of sand-cement-mortar.
¬¬ Apply Dr. Fixit Roofseal, diluted with ¬¬ Each bay size should not be more than
water in 1:1 proportion as the primer 10 sq. m. (3.25 m. x 3.25 m.) and the
to a clean, smooth and dry surface areas of the bay near the parapet wall
using a brush or roller in saturated should not be more than 2.25 sq.m.
surface dry condition. 7
¬¬ Finish the laying of the screed and
¬¬ Allow the primer to dry before let it get completely dried and cured.
applying Dr. Fixit Roofseal. Extend
¬¬ After this, remove the wooden battens
the primer over the angle fillets, up to
and fill with a compressible board, for
the drip mould on the parapet wall.
e.g. bitumen impregnated board or 1 2 3 4 5 6
Application extruded polystyrene foam sheets.

¬¬ Apply the first coat of Dr. Fixit ¬¬ Finally, fill the top of the joints with
Roofseal. Dr. Fixit PU Sealant.

Dr. Fixit Pidicrete URP Dr. Fixit Bathseal Tape Dr. Fixit Roofseal Dr. Fixit PU Sealant
SBR latex for waterproofing Leak-proof sealing tape for Bituminous waterproof coating One part non-sag polyurethane
and repairs pipe wrapping for new roofs and terraces sealant
19
PITCHED SLOPING ROOF

Waterproofing to Prevent
Leakages from Sloping Roofs

Dr. Fixit Newcoat

IPR 7
Methodology System Life Heavy-duty, fibre-reinforced, UV-resistant,
Expectancy: elastomeric waterproofing coating system
SURFACE PREPARATION Application on Sloped Roofs
7 years
¬¬ Clean the surface thoroughly to and use steel screws for fixing so ¬¬ Peel off the release film from the
get rid of all contaminants like dust, as to avoid rusting. After drilling Dr. Fixit Samshield XL self-
traces of curing compound, oil and holes and before fixing the screws, adhesive side and start unrolling
grease. fix Dr. Fixit Bathseal Tape on the the membrane and press it to the
¬¬ Remove all surface imperfections, bottom as well as top sides of the surface.
protrusions, structurally unsound batten. This will ensure a perfect ¬¬ Smoothen the membrane from
and loose concrete, and repair with seal around the screwed area. the centre to the edges with a
polymer modified mortar using The battens must have enough wooden press in order to remove
Dr. Fixit Pidicrete URP. number of grooves depending upon entrapped air.
the length of the roof to allow for
Priming efficient drainage of water in case ¬¬ Use an iron roller for rolling on top
there is breakage of tiles. of the applied membrane to ensure
¬¬ Apply Dr. Fixit Primeseal to a clean, a proper and strong adhesion of the
smooth surface using a brush or ¬¬ Apply the third coat of Dr. Fixit bitumen compound with the base.
roller. Newcoat all over the area covering
the wooden batten. ¬¬ Provide a 50 mm selvedge on one
¬¬ Allow the primer to dry before side of the membrane to give a
applying Dr. Fixit Newcoat. During ¬¬ Carefully fix tiles on the batten. bitumen-to-bitumen contact on the
application of Dr. Fixit Primeseal, Take care not to rupture the coating overlaps. 1 Concrete Roof
always maintain the saturated while fixing tiles. 8
¬¬ Lay a geotextile membrane of 120 2 Dr. Fixit Primeseal
7
surface dry condition. ¬¬ Never fix the batten by hammering gsm as a protection layer over the 3 Dr. Fixit Newcoat (1st Coat)
nails in the concrete. It will damage Dr. Fixit Samshield XL membrane.
6
Application on PCC below the Raft 4 Glass Fibre Mesh
the roof. Always use a drill machine 5
Slab ¬¬ Carefully fix tiles on the batten.
to fix screws. 5 Dr. Fixit Newcoat (2nd Coat) 4
Take care not to rupture the coating
¬¬ Apply the first coat of Dr. Fixit 6 Dr. Fixit Newcoat (3rd Coat) 3
Given below is an alternative while fixing tiles. 9
Newcoat and while it is still wet, lay 7 Wooden Battens 2
an ‘open-woven’ glass fibre mesh method. ¬¬ Never fix the batten by hammering
8 Roof Tiles 1
measuring 2.5 x 2.5 mm. Allow it to nails in the concrete. It will damage
Dr. Fixit Samshield XL 1500 / 2100 the roof, the roof concrete, the 9 Stainless Steel Screw
soak completely.
Priming membrane and the batten. Always
¬¬ Immediately, apply the second coat
use a drill machine to fix screws.
of Dr. Fixit Newcoat to embed the ¬¬ Apply Dr. Fixit Torchshield Primer Wooden Batten
By fixing screws, that area will with Grooves
mesh in coating. Allow this to dry to a clean, smooth and dry surface
still remain waterproof, as the
completely. using a brush or roller. Allow the
Samshield membrane does not
¬¬ Fix the wooden battens by drilling primer to dry before applying
form a hole, but adheres to the
Dr. Fixit Samshield XL.
screw itself.

Dr. Fixit Pidicrete URP Dr. Fixit Newcoat Dr. Fixit Bathseal Tape Dr. Fixit Samshield
SBR latex for waterproofing and repairs Heavy duty reinforced acrylic waterproofing coating Leak-proof sealing tape for pipe wrapping Self-adhesive bituminous membrane

21
EXPOSED FLAT EXPOSED FLAT
ROOF ROOF

Exposed Waterproofing
Exposed Waterproofing
System for Flat Roofs
System for Flat Roofs
System Life Reliable lightweight waterproofing System Life Reliable lightweight waterproofing membrane
membrane system with UV-resistant Dr. Fixit Torchshield AP 4160
Expectancy: Expectancy: system with UV-resistant mineral finish
Dr. Fixit Torchshield AM 4160 mineral finish Dr. Fixit Torchshield AM 4160
5 years 10 years

EFR 5 EFR 10
Methodology Methodology
SURFACE PREPARATION SURFACE PREPARATION

A thorough surface preparation is a ¬¬ The membrane must go over the 1


A thorough surface preparation is a ¬¬ The surface area of Dr. Fixit 1
Concrete Slab Slab
must over the entire roof area. angle fillet at the parapet walls must over the entire roof area. Lay the
Torchshield AM 4160 has a
2 Screed 2 Screed
¬¬ Conduct flashing on the parapet screed M 20 grade modified with mineral slate on the surface. Leave
Priming 3 Angle Fillet Dr. Fixit Pidiproof LW+ with a it exposed to the atmosphere and 3 Angle Fillet
wall with a C-shaped aluminium
Prime the surface with Dr. Fixit strip nailed (with SS Screws) 4 Dr. Fixit Torchshield Primer slope of 1 in 100, with at least 50 terminate with a flashing strip 20 3 Dr. Fixit Torchshield Primer
Torchshield Primer. Allow it to dry for to the vertical substrate at the mm thickness at the drain outlet. cm above the slab.
5 Dr. Fixit Torchshield AM 4160 4 Dr. Fixit Torchshield AP 4160
termination of the membrane. It can The screed must be cured and dried
8 to 10 hours.
6 Aluminium Flashing Strip
¬¬ Finish the top edge of the 5 Dr. Fixit Torchshield AM 4160
be tucked into a groove measuring completely.
with SS Screws membrane with aluminium flashing
Application 12 mm x 12 mm into the parapet of 2 mm thickness, sealed with 6 Aluminium Flashing
7 Dr. Fixit Silicone Sealant Priming
wall, 15 - 20 mm above the angle Dr. Fixit PU Sealant or Dr. Fixit 7 Dr. Fixit PU Sealant/
¬¬ Screed the mother slab with M 20 fillet. Thereafter, apply a single
grade concrete, to a slope of 1 in Prime the surface with Dr. Fixit Silicone Sealant. Dr. Fixit Silicone Sealant
component Dr. Fixit PU sealant or Torchshield Primer. Allow it to dry for
100, with at least 50 mm thickness a ‘neutral-cure’ silicone sealant to fill ¬¬ Provide Dr. Fixit roofing accessories
at the outlet. 8 to 10 hours.
the gap and seal it. such as roof drains, flashing
¬¬ Wrap all the pipe fittings and Application on PCC below the Raft strips, etc. as per standard roofing
¬¬ Provide Dr. Fixit roofing accessories
drainage fittings with Dr. Fixit Slab practices.
such as roof drains, flashing
Bathseal Tape. 8
strips, etc. as per standard roofing
¬¬ Start the application of the first 7
¬¬ Carry out the priming using practices.
layer of Dr. Fixit Torchshield AP
Dr. Fixit Torchshield Primer.
7 4160 (plain finish APP based). The
¬¬ Torch over using the APP based 6 application must start from the
membrane - Dr. Fixit Torchshield outlet, going towards the centre of
AM 4160 - with a mineral or slate the roof area.
5 4 5
finish of 4 mm thickness. Ensure 6
overlaps of 100 mm with factory- ¬¬ Lay the first layer up to over the
4
3 angle fillet only. 3
controlled / demarcated overlaps in 1
the membrane. 2 ¬¬ Lay the second layer of
¬¬ While torching in the overlaps, press Dr. Fixit Torchshield AM 4160
1
evenly to bleed out the bitumen in a perpendicular direction to the 2

out of the overlap. A ‘bead’ formed first membrane, starting from 150
thereof, must not be flattened with to 200 mm on the parapet wall -
the steel trowel. downward - and covering the angle
fillet. This is a mineral-finished
APP based membrane of 4 mm
thickness.

Dr. Fixit Torchshield Dr. Fixit Pidicrete URP Dr. Fixit Pidiproof LW+ Dr. Fixit Pidiproof LW+ Dr. Fixit Torchshield Dr. Fixit PU Sealant Dr. Fixit Silicone Sealant
APP / SBS modified bitumen SBR latex for waterproofing and repairs Integral liquid waterproofing compound Integral liquid waterproofing APP / SBS modified bitumen One part non-sag polyurethane Acetic cure silicone sealant
based membrane for plaster and concrete compound for plaster and based membrane sealant
concrete 23
WATERPROOFING
ACCESSORIES

ROOFING ACCESSORIES FOR


COMPREHENSIVE WATERPROOFING
Secure method for termination of
Dr. Fixit RoofIX FLASHING membranes on roofs and unique
Dr. Fixit RoofIX DRAIN accessory for effective drainage of water

WPA
Methodology

Roofing accessories are extremely directly onto the substrate just ¬¬ Form triangle fillets measuring 50
important while installing above the termination level of the x 50 mm on all vertical upstands.
waterproofing membranes as they
ensure standardisation in the fixtures
waterproofing system.
Dr. Fixit Roofix Drain
The fillet should be prepared in
concrete admixed with 10 - 15% of
Dr. Fixit Pidicrete URP, by weight
External
Walls
and a long-lasting installation.
¬¬ Dr. Fixit Roofix Drain is an of cement.
Dr. Fixit Roofix Flashing important accessory that is unique
and comes along with a leaf ¬¬ Apply the selected Dr. Fixit
¬¬ A flashing is a metallic strip
grating. This roof drain is designed Waterproofing System for upstand
generally in a non-corroding type
to effectively collect water in area, depending upon the type of
of metal into which waterproofing
the lowest end of the roof at the roof, and other parameters. The
membranes are tucked in. This
parapet junctions or in the middle treatment should always be taken
eliminates the need to insert the
of the roof, to which the slope is up over these angle fillets.
membrane after cutting a groove
into the parapet or side wall — cast so the water runs off into it. ¬¬ Terminate all vertical upstands as
which also makes it look shabby ¬¬ There are two types of Dr. Fixit per standard termination details.
— and is often left to the skill of the Roofix Drains: ¬¬ Seal the expansion joint with
applicator. filler board, with a backer rod of
a. `End drain’ for fixing at parapet
¬¬ Dr. Fixit Roofix Flashing is an wall junctions closed cell polyethylene foam or of
extruded, 4-bend premium grade extruded polystyrene, inserted.
b. `Circular drain’ which is fixed in
powder-coated termination flashing ¬¬ Fill the joint with selected sealant.
the middle portions of the roof.
for a wide range of waterproofing
systems. Once installed, it will ¬¬ Place the expansion joint cover over
Tackling Expansion Joints in the joint as shown in the illustration,
protect the waterproofing system
Roofs in a way that water will drain off on
from any water penetration from
vertical upstands, roof protrusions, to the roof.
¬¬ Clean the substrate with a broom
duct entries, etc. Dr. Fixit Roofix brush or compressed air. ¬¬ Seal horizontal joints with a seal
Flashing’s revolutionary design also tape.
¬¬ Construct a masonry upstand to a
helps to prevent any mouth opening
minimum height of 250 mm.
at the vertical termination area.
Dr. Fixit Roofix Flashing can
be fixed using standard one-
inch SS screws and Rawl plugs

Dr. Fixit Roofix Drain Rain Water Outlet Spout Dr. Fixit Roofix Flashing

25
EXTERNAL WALLS

EXTERNAL WALLS WITH


WATERPROOFING COATING

System Life High-performance elastomeric waterproof


Expectancy: coating for leak-free exterior walls
Dr. Fixit Raincoat 10 years

EWWP 5
Methodology
SURFACE PREPARATION Priming
1 Spalled Plaster
¬¬ Ensure a complete surface Prime the surface with Dr. Fixit
preparation prior to application. Primeseal diluted 2:1 with water, 2 Exposed Brick Masonry
Remove all loose dirt, dust and oil, maintaining the saturated surface dry 3 Plaster Reinstated Using PMM
etc. from the surface.
¬¬ Check for all surface cracks and
condition. Allow this to dry completely.
Application
Mixed with Dr. Fixit Pidicrete URP
4 Column Podium
clean them to remove all loose 5 Separation Joint Filled Using PMM
laitance and wash with water. ¬¬ Apply the first coat of Dr. Fixit Dr. Fixit Pidicrete URP
Raincoat without dilution
¬¬ Apply the crack-filler — Dr. Fixit 6 Plaster Cracks Filled with
maintaining the spreading rate. Dr. Fixit Crack-X Shrinkfreee
Crack-X Paste / Shrinkfree — Allow to dry for 6 to 8 hrs
depending on the width of crack 7 Primer Coat of Dr. Fixit Primeseal
(Use paste for cracks up to 3 - 5 mm ¬¬ Apply the second coat in a direction 8 Separation Joint RCC-Masonry
and Shrinkfree for cracks up to 10 perpendicular to the first coat,
9 2 Coats of Dr. Fixit Raincoat
mm). Use a putty blade by pressing ensuring complete coverage of
10 Beam
the material properly in cracks. the area.

¬¬ Remove the loose plaster and


re-do using polymer modified
10
mortar modified with Dr. Fixit
9
Pidicrete URP.
8

Dr. Fixit Crack-X Shrinkfree Dr. Fixit Pidicrete URP Dr. Fixit Primeseal Dr. Fixit Raincoat
100% shrink-free crack filler SBR latex for waterproofing Efflorescence-resistant Acrylic elastomeric exterior
and repairs penetrative primer waterproof coating
27
PODIUM PODIUM
WATERPROOFING WATERPROOFING

Waterproofing for Dry Waterproofing for Dry


Podiums Podiums
System Life Highly flexible, tough and puncture-resistant System Life Reliable waterproofing system with flexibility
Expectancy: waterproofing system that sustains Expectancy: to accommodate structural movements
Dr. Fixit Extensa structural movements Dr. Fixit Flexicoat PU
15 years 10 years

PWP 15 PWP 10
Methodology Methodology
SURFACE PREPARATION Application SURFACE PREPARATION Application

¬¬ Remove all surface imperfections, ¬¬ After drying, spray-apply Dr. Fixit 1



Slab ¬¬ Remove all surface imperfections, ¬¬ Apply Dr. Fixit Flexicoat PU by a
1
protrusions, structurally unsound Extensa to achieve minimum protrusions, structurally unsound brush or trowel or squeegee in two Slab
2 Dr. Fixit Extensa
coats maintaining the spreading 2 Dr. Fixit Flexicoat PU
and loose concrete, and repair with thickness of 1.5 mm. 3 Geotextile
and loose concrete, and repair with
polymer modified mortar using polymer modified mortar using rate to achieve the desired Dry Film 3 Geotextile
¬¬ Apply Dr. Fixit Extensa through 4 Angle Fillet
Dr. Fixit Pidicrete URP. Dr. Fixit Pidicrete URP. Thickness or DFT of 1.5 mm. 4 Angle Fillet
compatible equipment only. It
5 Drip Mould
¬¬ Make angle fillets all around the cannot be sprayed through other ¬¬ Make angle fillets all around the ¬¬ Air-cure Dr. Fixit Flexicoat PU 5 Drip Mould
periphery of the podium wall with types of commonly available 6 Screed periphery of the podium wall with membrane for a minimum of 72
6 Screed
polymer modified mortar prepared sprayers. polymer modified mortar prepared hours at 27°C before placing the
with Dr. Fixit Pidicrete URP. with Dr. Fixit Pidicrete URP. protection.
¬¬ Place a geotextile fabric of 300 gsm
¬¬ Clean all surfaces with compressed over the membrane before laying ¬¬ Clean all surfaces with compressed ¬¬ Once the coat is dry, lay a layer of
air, and ensure they are free of the concrete screed of 75 mm air, and ensure they are free of geotextile membrane of 300 gsm.
loose materials, oils, form release (average) modified with Dr. Fixit loose materials, oils, form release ¬¬ After laying the geotextile
agents and other contaminants. Pidiproof LW+ with 1:100 slope. agents and other contaminants. membrane, overlay a screed of 75
It should be properly aligned with mm (average) of M 20 concrete
Priming Priming
drain outlets for efficient drainage grade for the protection of the
¬¬ Priming is generally not required of water. Priming is generally not required membrane and to provide a
on concrete substrates for Dr. Fixit on concrete substrates for Dr. Fixit proper slope for effective draining
Extensa. Flexicoat PU. of rain water.

6 6
5 5
4 4
3 3
2 2
1 1

Dr. Fixit Pidicrete URP Dr. Fixit Extensa Dr. Fixit Pidiproof LW+ Dr. Fixit Pidicrete URP Dr. Fixit Flexicoat PU
SBR latex for waterproofing and repairs Highly elastomeric and puncture resistant Integral liquid waterproofing compound SBR latex for waterproofing and repairs Pitch modified polyurethane membrane coating
waterproofing coating for plaster and concrete
29
PODIUM WATERPROOFING
WITH LANDSCAPING AND
SWIMMING POOL

Waterproofing Protection to
Swimming Pool at Podium or
any Other Floor

Dr. Fixit Extensa


Dr. Fixit Fastflex

PWP 10 - LSP
Methodology System Life Highly flexible, tough waterproofing system that
Expectancy: easily bears pressure exerted by water column
SURFACE PREPARATION
10 years
¬¬ Remove all surface imperfections, ¬¬ Extend the Dr. Fixit Extensa ¬¬ Treat the areas in the pool around
protrusions, structurally unsound coating up to the top and cover the insert pipes and the wall-to-floor
and loose concrete, and repair with the overflow concrete channels all junctions by embedding a glass fibre
polymer modified mortar using around the periphery of the pool. mesh of 2.5 mm x 2.5 mm weighing
Dr. Fixit Pidicrete URP. 50 gsm between the first and second
¬¬ Over this, place a 3.5 mm fleece
¬¬ Clean all surfaces with compressed coats. Place them when the first
backed self-adhesive membrane ­-
air, and ensure they are free of coat is still wet. This will increase the
Dr. Fixit Samshield PS 3500.
loose materials, oils, form release waterproofing protection in these
Being self-adhesive, it will stick to
agents and other contaminants. areas.
Dr. Fixit Extensa and will serve
¬¬ Carry out the grouting for light as protection for the subsequent ¬¬ While the third coat of Dr. Fixit
Fastflex is wet, broadcast with clean proposed by the architects. If the ¬¬ Provision of drainage is absolutely
fitting casings, pipes, inserts, etc., short-creting that needs to be
and washed sand liberally and set drain cell board does not have a essential, which should be provided
provided in the concrete raft floor done (in case of a swimming pool).
along with the application. This will geotextile membrane over it, place by the customer on the advice of the
and walls using a Dr. Fixit Bathseal Carry out the short-creting over
provide a key for the subsequent Roff an appropriate membrane which architect or the consultant. Place soil
Grout, a non-shrink grout. a steel reinforcement installed in
adhesives that will be needed to fix the allows water to trickle through to the over the geotextile membrane.
accordance to the engineer’s advice,
¬¬ Wrap the inserts with Dr. Fixit swimming pool tiles. underside.
and to the required thickness.
Bathseal Tape to ensure a water- Use a wooden float to give it a
tight fitting, before grouting the ¬¬ After completing the tiling work, apply
smooth finish. Roff RTM epoxy grout to fill the
inserts. 11
1
¬¬ After a thorough curing of at least gaps in the tiles. Protect the entire Floor Concrete
Priming 3 - 4 days, take up Dr. Fixit Fastflex application against chlorine in the 2 Dr. Fixit Extensa
10
for application over the short-creted water that is generally used to clean 3 Steel Cage with Pedestal
Priming is generally not required surface. Just before this, apply angle the pools. 9
4 Short-Crete
on concrete substrates for Dr. Fixit fillets in polymer modified mortar
Extensa. ¬¬ For waterproofing of landscapes, it is 5 Dr. Fixit Fastflex (2 coats)
admixed with Dr. Fixit Pidicrete 8
extremely important to place Dr. Fixit 6 Dr. Fixit Fastflex (3rd coat with Sprinkled Sand)
URP all round the periphery of the Samshield PS 3500 over Dr. Fixit 7
Application on PCC below the Raft 7 Roff NSA & Roff RTM Tile Grout
swimming pool floor, at the parapet Extensa. 6
Slab 8 Concrete Wall
wall junctions. 5
¬¬ Provision of slope in landscaping
¬¬ Spray-apply Dr. Fixit Extensa to ¬¬ Initiate the application of Dr. Fixit
9 Pipe Inlet Fitting Dr. Fixit Bathseal Tape &
4
whether on roofs or podiums Dr. Fixit Bathseal Grout
achieve a minimum thickness of 2 Fastflex over a saturated surface 3
becomes mandatory. 10 Light Fitting Casing with Dr. Fixit Bathseal Grout &
mm. Apply Dr. Fixit Extensa using dry short-crete. A total of three coats Dr. Fixit Bathseal Tape 2
only designated equipment. It cannot should be applied in all, ensuring that ¬¬ Place drain cell boards from standard
11 Steel Grating
be sprayed through any other type companies over this. The specification 1
each coat of application dries before
of commonly available sprayers. taking up the next. of the drain board generally depends
upon the amount of water discharge
and the kind of landscaping as

Dr. Fixit Pidicrete URP Dr. Fixit Bathseal Grout Dr. Fixit Bathseal Tape Dr. Fixit Extensa Dr. Fixit Samshield Dr. Fixit Fastflex
SBR latex for waterproofing and repairs Non-shrink grout for pipe fitting Leak-proof sealing tape for pipe Highly elastomeric and puncture-resistant Self-adhesive bituminous membrane High-performance polymer modified
wrapping waterproofing coating cementitious coating
31
WET AREA
WATERPROOFING

Comprehensive System for


100% Leak-Free Bathrooms
System Life Easy to use multi product kit for bathroom
Expectancy: waterproofing
Dr. Fixit Bathseal
15 years

WW 15
Methodology
Surface Preparation
of open woven glass fibre mesh of Dr. Fixit Pidiproof LW+ can be laid
¬¬ Clean with compressed air or
2 mm x 2 mm. Do this immediately after 24 hours to fix these pipes in
pressure-wash all surfaces. Allow

Water
over the coating and allow it to soak position.
them to dry so they are free of loose
completely.
materials, oils, form release agents ¬¬ Begin the tiling work after finalising

Bodies
and other contaminants. ¬¬ Cover it with one additional coat the plumbing work in the bathroom
of Dr. Fixit Bathseal WPC over floor and wall. Use the Roff tiling
¬¬ Make angle fillets all around the
the angle fillets and allow it to dry adhesives and RTM tile grouts.
periphery of the wall with polymer
completely.
modified mortar prepared with ¬¬ After finishing these tasks, start
Dr. Fixit Pidicrete URP. ¬¬ Apply the second coat of Dr. Fixit fitting the sanitary ware. Fill the
Bathseal WPC after the first coat gaps around with Dr. Fixit Bathseal
¬¬ The gaps around the pipe inserts and
dries completely. Also, cover the Sealant to complete the bathroom
the floor traps, etc. should not be
angle fillets during the second coat waterproofing.
wider than 50 mm.
application.
Alternatively, Dr. Fixit Bathseal
Application ¬¬ After 24 to 72 hours, lay a concrete Plus can be applied as a high-
¬¬ Seal sanitary pipes entering through screed of 50 mm thickness on the performance, premium bathroom
the walls and floor with Dr. Fixit sunken portion. Sanitary pipes and waterproofing system in place of
Bathseal Tape and grout the gaps traps can be laid over this screed, Dr. Fixit Bathseal WPC.
with Dr. Fixit Bathseal Grout — the next day. Brickbat Coba using
a non-shrink cementitious grout. Tile

¬¬ Securely fit the ‘Nahani’ trap, etc. in Brickbat Coba


1500 mm
the same manner. Grout the gaps Screed
around it, too.
Roff Rainbow
¬¬ Now, apply the first coat of Dr. Fixit Tile Mate
Bathseal WPC in the sunken area
and extend up to 150 mm on walls

DRY AREA

WET AREA
1800 mm
and above the finished floor level
(FFL). Dr. Fixit Bathseal
Sealant
¬¬ Extend the coating in shower flash Sandwiched
Fibre Mesh
zone — 1500 mm wide x 1800 mm

300 mm
100 mm
Dr. Fixit
high. Bathseal WPC
¬¬ While this first coat of Dr. Fixit Dr. Fixit
Bathseal Grout
Bathseal WPC is still wet, cover all
Dr. Fixit Bathseal Tape
angle fillets with a 150 mm wide strip
Concrete Slab

Dr. Fixit Bathseal Tape Dr. Fixit Bathseal Kit


Wrapping tape for leak-free pipe fitting One-stop solution for leak-free bathrooms

33
SWIMMING POOL BELOW SWIMMING POOL BELOW
GROUND LEVEL GROUND LEVEL

System to Prevent Water Loss System to Prevent Water


FROM EXTERNAL SIDE Loss from internal sides
System Life Tough waterproofing system for below System Life Highly puncture-resistant and tough below
Expectancy: grade application Expectancy: grade waterproofing membrane system
Dr. Fixit Samshield XL 2100 Dr. Fixit Fastflex
10 years 10 years

SWP 10 SWP 10
Methodology Methodology
For Raft Slab and External Walls For Internal Areas ¬¬ After the second coat has completely
1
dried, apply the third coat of Dr. Fixit
PCC
1 Binding Concrete (PCC)
SURFACE PREPARATION SURFACE PREPARATION Fastflex and sprinkle coarse sand
2 Dr. Fixit Torchshield Primer 2 Dr. Fixit Torchshield Primer
while it is still wet. This will provide
¬¬ Clean all surfaces with compressed facilitate the reinforcement cage to 3 Dr. Fixit Samshield XL 2100
¬¬ Clean the internal surface areas
the key for subsequent tile adhesive 3 Dr. Fixit Torchshield AP 4160
air, and ensure they are free of be assembled so the RCC raft can be (horizontal and vertical) thoroughly
4 Geotextile Fabric materials. 4 Geotextile
loose materials, oils, form release cast over it. so they are free of all contaminants
agents and other contaminants. 5 Screed like dust, traces of curing ¬¬ Wrap the inserts with Dr. Fixit 5 Concrete Screed
Application on Retaining Wall compound, oil and grease. Bathseal Tape to ensure a water-tight
¬¬ Remove all surface imperfections, 6 Dr. Fixit Waterbar SW2020 6 Concrete Raft Slab
fitting.
protrusions, structurally unsound ¬¬ Place Dr. Fixit Waterbar SW 7 Protection Board ¬¬ Remove all surface imperfections, 7 Dr. Fixit Fastflex (2 coats)
and loose concrete, and repair with 2020 — a swellable, compressible, protrusions, structurally unsound ¬¬ Carry out the grouting for light fitting
casings, pipes, insert, etc., provided in 8 Dr. Fixit Fastflex
polymer modified mortar using adhesive strip — of 20 mm x 20 and loose concrete, and repair with
(3rd Coat with Sand)
Dr. Fixit Pidicrete URP. mm size in concrete joints in the polymer modified mortar using the concrete raft floor and walls using
retaining walls and at raft level while Dr. Fixit Pidicrete URP. a Dr. Fixit Bathseal Grout, a non- 9 Roff NSA &
Priming concreting. shrink grout. Roff RTM Epoxy Grout
¬¬ At internal side walls and raft
10 Light Fixture with
Carry out priming all over the blinding ¬¬ Provide angle fillets measuring 40 junction, cast angle fillets ¬¬ Liberally apply Dr. Fixit Fastflex
Dr. Fixit Bathseal Grout
concrete or PCC that is properly mm x 40 mm at the corners, all measuring 40 mm x 40 mm all around the insert pipes and around the
sandwiched light fittings with an open 11 Pipe Opening with
levelled using Dr. Fixit Torchshield around the swimming pool floor around the swimming pool floor.
and walls from external side. woven mesh for extra precaution. Dr. Fixit Bathseal Grout
Primer. Use a roller or brush over a
Application
dried surface. Allow the primer to dry ¬¬ Prepare the retaining wall surface ¬¬ Apply tiles using tile adhesives from
for 8 to 10 hours. by cleaning and priming it with 7 ¬¬ After complete curing of the raft the Roff range depending on whether
Dr. Fixit Torchshield Primer to 6 slab and retaining walls, apply the they are glass mosaics or ceramics.
Application on PCC below Raft Slab 6
receive the waterproofing system. first coat of Dr. Fixit Fastflex, ¬¬ After tile fixing, fill the grooves /
5
¬¬ Lay the SBS based self-adhesive maintaining the saturated surface
¬¬ Apply Dr. Fixit Samshield XL tile joints with epoxy based
membrane — Dr. Fixit Samshield 4 dry condition. Roff RTM tile grouts.
2100 starting from the bottom 11
XL 2100 — by providing an overlap of external wall, right up to the 3 ¬¬ While the coat is still wet, embed 9
10
of at least 100 mm. ground level. Ensure that Dr. Fixit 2 a glass fibre mesh measuring 2.5 8

¬¬ Extend the membrane to the Samshield XL 2100 is applied mm x 2.5 mm of 50 gsm over the 7
maximum extent of the area of the up to at least 300 mm above the 1
angle fillets as a reinforcing strip 6
blinding concrete. ground level. and allow it to soak completely.
5
Immediately apply one additional
¬¬ Lay geotextile membrane of 120 gsm ¬¬ Once the application is complete, 4
coat to sandwich this glass fibre
as a protection layer over Dr. Fixit place a bituminous protection board
mesh between the Dr. Fixit Fastflex 3
Samshield XL 2100 membrane. of 4 mm thickness or a dimpled
coatings. 2
HDPE drainage board of 12 mm
¬¬ A screed of 50 mm must be overlaid
thickness for protection. ¬¬ Apply the second coat of Dr. Fixit 1
of M 20 concrete grade, which will
Fastflex.

Dr. Fixit Pidicrete URP Dr. Fixit Samshield Dr. Fixit Waterbar Dr. Fixit Pidicrete URP Dr. Fixit Fastflex Roff RTM Epoxy
SBR latex for waterproofing and repairs Self-adhesive bituminous Flexible adhesive waterstop strip SBR latex for waterproofing and repairs High-performance polymer modified Non-shrink grout for pipe fitting
membrane cementitious coating
35
GROUNDWATER
RESERVOIRS

Waterproofing of
Groundwater Reservoirs

Dr. Fixit Samshield XL


Dr. Fixit Fastflex

GRWP 10
Methodology System Life High performance waterproofing for water
Expectancy: tanks and ground reservoirs
SURFACE PREPARATION
10 years
¬¬ For horizontal application, ¬¬ Prime the area with Dr. Fixit ¬¬ After properly curing the screed,
smoothen and level the new Torchshield Primer which is take up the task of casting the
concrete layer. Leave it to mature solvent-based. Leave it to dry for 8 concrete raft.
for at least 72 hours. to 10 hours, or overnight.
Waterproofing of the Exterior Side
¬¬ Before laying the waterproofing ¬¬ Apply the Dr. Fixit Samshield XL of the Retaining Wall
membrane, clean the waste off membrane along the length and
the surface. Remove all surface breadth of the PCC area. Peel off ¬¬ Apply Dr. Fixit Samshield XL on
imperfections, protrusions, the silicone release paper and stick the external side using the same
structurally unsound and loose it over the primed surface. Use a procedure as given above.
concrete and repair with polymer roller to press it firmly and ensure ¬¬ After applying Dr. Fixit Samshield
modified mortar using Dr. Fixit there are no wrinkles. Keep pressing XL on each level of the reservoir’s
Pidicrete URP. and straightening the membrane till exterior, place a protection board of mixture is obtained. The product ¬¬ After 8 hours again, when the
¬¬ Where the separate concrete layers it is firmly adhered to the surface. highly compressible board, to allow is brush-applied to achieve 1 mm second coat is wet, apply the third
are poured at different levels, fill ¬¬ Lay down rolls of Dr. Fixit the backfilling of soil. in 2 coats of application. Dr. Fixit coat of Dr. Fixit Fastflex. This is
the gaps and smoothen to obtain a Samshield XL with side laps of Fastflex forms a highly elastomeric basically meant for broadcasting
Construction of the Basement membrane when cured and sustains cleaned and washed sand liberally
comparatively smooth surface. 50 – 60 mm on its ‘selvedge’. The
Retaining Wall of the Reservoir the water movement in large water over it.
¬¬ When cleaning the substrate, end-laps that come every 10 metres
length-wise should measure containing structures. It has an ¬¬ This will facilitate easy plastering
remove any pollutants — such as ¬¬ Take up waterproofing for the
100 mm. elongation of 150%. of 20 mm over the Dr. Fixit
chemicals, curing agents etc. which internal side of the retaining wall
may affect the membrane adhesion. ¬¬ Carry out the application for using Dr. Fixit Fastflex. ¬¬ After the first coat of application, Fastflex membrane. This finishes
the entire area in this manner. place a glass fibre mesh of 2.5 mm the internal surface of the water
Installation of Dr. Fixit Samshield
¬¬ After thorough surface preparation,
Application should be done when x 2.5 mm over the membrane, while reservoir.
on a pre-wetted concrete surface
Membrane for Waterproofing the coating is still wet.
the weather is favourable and with water, carry out the application ¬¬ After the plaster apply Dr. Fixit
Floor of the Reservoir should not be kept exposed for a of Dr. Fixit Fastflex in 3 coats. ¬¬ After the first coat dries in about 8 Safeguard for anti-microbial/
¬¬ Level out the PCC / blinding long time. hours or so, apply the second coat anti-fungal/anti-algae properties
Note: Dr. Fixit Fastflex is a
concrete to see whether the surface ¬¬ Overlay a geotextile immediately, over it, covering up the mesh on the and prevent the growth of harmful
cementitious acrylic membrane
is cleaned of any debris followed by casting a levelled first coat. elements in internal area of potable
that only needs mixing with a
and protrusions. It must be concrete screed of 50 mm of water tanks.
forced action mixer attached to a
completely dry to begin the M 20 grade. suitable mixing paddle, until the
waterproofing process using two parts of the product become
Dr. Fixit Samshield XL. homogeneous and a lump-free

Dr. Fixit Pidicrete URP Dr. Fixit Samshield Dr. Fixit Fastflex Dr. Fixit Safeguard
SBR latex for waterproofing and repairs Self-adhesive bituminous membrane High performance polymer modified cementitious coating Safe waterproof coating for internal walls of potable water tanks

37
NOTES

39
Pidilite Industries Limited
Construction Chemicals Division
Ramkrishna Mandir Road, Post Box No. 17411
Andheri (E) Mumbai 400059 INDIA
Tel +91-22-2835 7000 • Fax +91-22-2835 7008
www.doctor-fixit.com • techhelp@drfixit.co.in

For technical assistance, please contact us on 1800 3002 5502


13CC1183-GW-BK-ENG-10/13

DISCLAIMER The product information & application details given by the company & its agents has been provided in good faith & meant to serve only as a general
guideline during usage. Users are advised to carry out tests & take trials to ensure on the suitability of products meeting their requirement prior to full scale usage
of our products. Since the correct identification of the problems, quality of other materials used and on-site workmanship are factors beyond our control, there are
no expressed or implied guarantee/ warranty as to the results obtained. The Company does not assume any liability or any consequential damage for unsatisfactory
results, arising from the use of our products.

Design Pidilite Design Studio

Potrebbero piacerti anche