Document Information
Revision History
This revision of the manual documents the following network element and the corresponding
feature pack or higher.
If a different feature pack of 8600 products, please refer to the relevant product document
program on the Tellabs and Coriant Portal by navigating to www.portal.tellabs.com > Product
Documentation > Data Networking > Tellabs 8600 Smart Routers > Technical Documentation.
This manual is protected by U.S. and international copyright laws, conventions and treaties. Your right to use this manual is
subject to limitations and restrictions imposed by applicable licenses and copyright laws. Unauthorized reproduction, modification,
distribution, display or other use of this manual may result in criminal and civil penalties.
The specifications and information regarding the products in this manual are subject to change without notice. All statements,
information, and recommendations in this manual are believed to be accurate but are presented without warranty of any kind,
express or implied. Users must take full responsibility for their application of any products.
Adobe ® Reader ® are registered trademarks of Adobe Systems Incorporated in the United States and/or other countries.
2
Document Information
Term Explanation
ASIC Application Specific Integrated Circuit
BFD Bidirectional Forwarding Detection
BGP-4 Border Gateway Protocol version 4
BMP Broadband Management Protocol. A communication protocol which is used between
8600 network elements and 8000 network manager.
BSC Base Station Controller
CAC Connection Admission Control
CCN Configuration Change Notification
CDC Control and DC Power Card
CES Circuit Emulation Service
CLI Command Line Interface
Control card The control card in the 8600 system consists of a Control and DC Power Card CDC
(used in 8630 Smart Router and 8660 Smart Router), Switching and Control Module
SCM (used in 8611 Smart Router). In 8000 Intelligent Network Manager and CLI
referred to as unit.
CPU Central Processor Unit
CSMA/CD Carrier Sense Multiple Access/Collision Detect
CU Control functionality (used in 8615 Smart Router and 8665 Smart Router)
ECMP Equal Cost Multi Path routing
EEPROM Electrically Erasable Programmable Read Only Memory
EMC Electromagnetic Compatibility
EMI ElectroMagnetic Interference
ERM Electromagnetic Compatibility and Radiospectrum Matters
ESMC Ethernet Synchronization Message Channel
Fan One fan in a fan module
Fan Module A module consisting of two or more fans, the mechanics and possibly the control
electronics
FIFO First In First Out memory
FLASH Electrically erasable and programmable memory type
FMC Fixed mobile convergence
FTP File Transfer Protocol
FTP Foil Shielded Twisted Pair
GND Ground
GUI Graphical User Interface
3
Document Information
I2C Bidirectional two-wire serial bus that provides a communication link between
integrated circuits (ICs).
IEEE Institute of Electrical and Electronics Engineers
IP Internet Protocol
IRB Integrated Routing and Bridging
IS-IS Intermediate System to Intermediate System (Interior Gateway Protocol)
I-TEMP Industrial Temperature Range
ITU-T International Telecommunication Union - Telecom Standardization Sector
LDP Label Distribution Protocol
LED Light-Emitting Diode
LER Label Edge Router
Line card The line card in the 8600 system consists of an Ethernet Line Card (ELC1), Interface
Module Concentrator (IFC) and up to two Interface Modules (IFMs) (used in 8630
Smart Router and 8660 Smart Router). In 8000 Intelligent Network Manager and
CLI referred to as unit.
Line unit The line unit in the 8665 Smart Router is the basic building block for the element.
One line unit contains always the traffic functionality (LU) and, optionally control
functionality (CU).
LU Traffic functionality (used in 8615 Smart Router and 8665 Smart Router).
LU1 Line Unit in 8665 Smart Router.
LSP Label Switched Path
LSR Label Switch Router
LTE Long Term Evolution
MAC Media Access Control Sublayer of Data Link Layer
MP-BGP Multiprotocol Border Gateway Protocol
MPLS Multiprotocol Label Switching
MTU Maximum Transfer/Transmission Unit
NE Network Element
NEBS Network Equipment Building Systems
NRTL Nationally Recognized Testing Laboratory
OAM Operation, Administration and Maintenance
OSPF Open Shortest Path First
OSS Operating Support System
PCML Pseudo Current Mode Logic
PFC Power Factor Correction Circuit
PHY Physical Layer Device
PIM Power Input Module
PLL Phase Locked Loop
PPP Point-to-Point Protocol
4
Document Information
PPS Pulse-per-Second
PSN Packet Switch Network
PSU Power Supply Unit
PWE3 Pseudowire Edge to Edge Emulation
PWM Pulse Width Modulation
QoS Quality of Service. A way of guaranteeing a defined performance through the
network. Implementation of QoS in the network means specific bandwidth, latency,
jitter and loss guarantees per each traffic flow.
RAN Radio Access Network
RFC Request For Comments
RIB Routing Information Base
RISC Reduced Instruction Set Computer
RNC Radio Network Controller
RSVP-TE Resource Reservation Protocol – Traffic Engineering
RTC Real Time Clock
SCI Station Clock Input
SCO Station Clock Output
SDH Synchronous Digital Hierarchy
SDRAM Synchronous Dynamic Random Access Memory
SEC Synchronous Equipment Clock
SFP Small Form-Factor Pluggable. A transceiver type used in 8600 IFMs.
SM Single Mode
SNMP Simple Network Management Protocol
SONET Synchronous Optical Network
SSM Synchronization Status Messages
STM Synchronous Transfer Mode
STP Shielded Twisted Pair
SU1 Switch Unit in 8665 Smart Router
VCCV Virtual Circuit Connectivity Verification
VLAN Virtual LAN (Local Area Network)
VPN Virtual Private Network
VRF VPN Routing and Forwarding Table
VRRP Virtual Router Redundancy Protocol
VSI Virtual Switching Instances
WFQ Weighted Fair Queueing
WiMAX Worldwide Interoperability for Microwave Access
WRED Weighted Random Early Detection
5
Document Information
XFP 10-Gigabit Small Form-Factor Pluggable. A transceiver type used in 8600 ELC1
line card.
Compliance Statement
Hereby, Coriant Oy declares that this product is in compliance with the essential requirements and
other relevant provisions of Directive 1999/5/EC and Directive 2011/65/EU.
Federal Communications Commission (FCC) Rules require that you be notified of the following:
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
6
Table of Contents
Table of Contents
Objectives....................................................................................................................................................................... 10
Audience......................................................................................................................................................................... 10
8600 Smart Routers Technical Documentation.............................................................................................................. 10
Document Conventions .................................................................................................................................................. 13
Documentation Feedback............................................................................................................................................... 13
7
Table of Contents
6 Technical Specifications............................................................................................. 48
8
Table of Contents
9
About This Manual
• Objectives
• Audience
• 8600 Smart Routers Technical Documentation
• Document Conventions
• Documentation Feedback
Objectives
The goal is to describe the network element features of 8665 Smart Router.
Audience
This manual is intended for system specialists and personnel involved in network planning.
The document numbering scheme consists of the document ID, indicated by numbers, and the
document revision, indicated by a letter. The references in the Related Documentation table below
are generic and include only the document ID. To make sure the references point to the latest
available document versions, please refer to the relevant product document program on the Tellabs
and Coriant Portal by navigating to www.portal.tellabs.com > Product Documentation & Software
> Data Networking > 8600 Smart Routers > Technical Documentation.
10
About This Manual
11
About This Manual
12
About This Manual
Document Conventions
This is a caution symbol. It indicates that damage to equipment is possible if the instructions
are not followed.
This is a warning symbol. It indicates that bodily injury is possible if the instructions are not
followed.
Documentation Feedback
Email: fi-documentation@coriant.com
13
8600 Smart Routers Discontinued Products
14
Safety Notes
Safety Notes
This chapter lists safety notes and their translations for 8600 network elements.
Intended Purpose
Das Gerät soll nur für den vorgesehen Einsatzzweck verwendet werden.
CAUTION: Do not insert an RJ-11 (telephone) plug into Ethernet or E1/T1 ports. Equipment
damage may result.
ACHTUNG: Stecken Sie keine RJ-11 (Telefon) Stecker in die Ethernet oder E1/T1 Anschlüsse
da dieses zu einer Beschädigung des Gerätes führen kann.
CAUTION: Do not climb on or stand on the 8600 network element. Neither the network element
nor its enclosure is designed to support the weight of a person.
ACHTUNG: Steigen Sie oder stellen Sie sich nicht auf das 8600 Netzwerk Element. Weder
des Netzwerk Element noch das Gehäuse sind dafür ausgelegt worden das Gewicht einer
Person zu tragen.
WARNING: No other types of lasers can be used than supplied and approved by Coriant. If
other types are used, the laser class and compliance to laser safety and EMC standards
must be checked.
WARNUNG: Verwenden Sie keine anderen als die von Coriant gelieferten und zugelassenen
Lasertypen. Falls Sie andere Typen verwenden, müssen die Laserklasse und die Einhaltung
von Lasersicherheits- und EMV-Normen geprüft werden.
15
Safety Notes
WARNING: Install only lasers that have been demonstrated to meet Class 1 eye safe levels by
a Nationally recognized Authority such as The Food and Drug administration's 21CFR1040
Laser Energy Source, UL 60950-1 Information Technology equipment and European norms
EN60950-1, EN60825-1 and EN60825-2. Failure to use laser transceivers which meet these
standards could result in eye damage to users or service personnel working around the
equipment.
WARNUNG: Installieren Sie nur Laser der Klasse 1 die die Augenschutz Richtlinien
der staatlich anerkannten Organisationen wie z.B. The Food and Drug administration’s
21CFR1040 Laser Energy Source, UL 60950-1 Information Technology equipment oder die
Europa Normen EN60950-1, EN60825-1 und EN60825-2 erfüllen. Laser die diese Standards
nicht erfüllen können zu Verletzungen an Augen des Benutzers und des Service Personals
das in der Nähe der Geräte arbeitet führen.
WARNING: Optic operation should be verified by observing the status LEDs. Do not look into
the laser or fiber to verify operation.
WARNUNG: Überprüfen Sie die Funktionstüchtigkeit der Optischen Einheit anhand der Status
LED. Schauen Sie nie in den Laser oder die Glasfaser um die Funktion zu prüfen.
WARNING: Because invisible radiation may be emitted from the aperture of the port when no
fiber cable is connected, avoid exposure to radiation and do not stare into open apertures.
WARNUNG: Aus der Stecker Öffnung können unsichtbare Strahlen emittieren wenn kein
Glasfaserkabel angeschlossen ist. Vermeiden Sie es sich den Strahlungen auszusetzen und
starren Sie nicht in die Öffnungen.
Jewelry Removal
WARNING: Before working on equipment that is connected to power source, remove jewelry
(including rings, necklaces, and watches). Metal objects will heat up when connected to
power and ground and can cause serious burns or weld the metal object to the terminals.
WARNUNG: Bevor Sie an Geräten arbeiten die an eine Spannungsversorgung angeschlossen
sind, entfernen Sie all Ihren Schmuck (einschließlich Ringe, Ketten und Uhren). Metallobjekte
erhitzen sich wenn sie einen Kurzschluss zwischen Spannungsversorgung und Masse/Erdung
verursachen. Dieses kann zu schweren Verbrennungen führen oder das Anschweißen an die
Anschlussklemmen zur Folge haben.
16
Safety Notes
CAUTION: Electrical interfaces may require external protection devices to safeguard against
overvoltages, transients, earth potential differences and/or power cross-contacts.
ACHTUNG: Elektrische Anschlüsse benötigen evtl. externe Schutzschaltungen
um sie vor Überspannung, Einschaltspitzen, Erdpotentialunterschieden und/oder
Fremdspannungsüberlagerung zu schützen.
CAUTION: While handling the modules (Interface Modules, Line Modules, High Speed
Modules, SCM, CDC, Line Cards, Power Modules, Power Input Modules and Fan Modules) of
the 8600 network elements, always take care of proper handling, e.g. do not bend or twist
the modules, do not touch the components on the modules, take care of good ESD working
practices, do not use excessive force while inserting or removing the modules, do not drop
the modules.
ACHTUNG: Achten Sie darauf, dass Sie mit den Modulen (Schnittstellenmodulen,
Netzmodulen, Hochgeschwindigkeits-Netzmodulen, SCM, CDC, Netzkarten, Netzteilmodulen,
Netzeingangsmodulen und Lüftermodulen) der 8600-Netzwerkelemente sorgsam umgehen
und diese nicht verbiegen oder verdrehen. Berühren Sie nicht die Bauteile auf den Modulen.
Wenden Sie beim Ein- oder Ausbauen der Module keine übermäßige Kraft an und lassen Sie
die Module nicht fallen. Beachten Sie außerdem die Arbeitsrichtlinien im Zusammenhang
mit elektrostatischer Entladung.
WARNING: For US usage: this equipment must only be used with a Nationally Recognized
Testing Laboratory (NRTL) approved power supply.
WARNUNG: Für den Gebrauch in den USA: Dieses Gerät darf nur mit einer von einer national
anerkannten Test Einrichtung (NTRL) zugelassenen Spannungsversorgung betrieben werden.
WARNING: Read the installation instructions before you connect the system to its power
source.
WARNUNG: Lesen Sie die Installationsanweisungen bevor Sie das System an die
Spannungsversorgung anschließen.
17
Safety Notes
Lightning Activity
WARNING: Do not work on the system or connect or disconnect cables during periods of
lightning activity.
WARNUNG: Arbeiten Sie während eines Gewitters mit Blitzschlag nicht an dem Gerät oder
schließen Sie auch keine Kabel an bzw. trennen Sie keine ab.
18
1 8665 Smart Router Overview
1.1 Subrack
The 8665 Smart Router subrack can be installed into 600 mm deep 19” rack. The outer dimensions
of the subrack are 445 mm/ 17.51 in x 666 mm/26.22 in x 445 mm/17.51 in (w x h x d), the width
with the integrated side adapter front flange is 483 mm/19.01 in.
The 8665 Smart Router is 15U high and designed for front to back airflow installations. The 8665
Smart Router subrack allows the subrack and backplane serial numbers to be read by the software
from an EEPROM device, thereby making them visible on 8000 Intelligent Network Manager and
CLI.
19
1 8665 Smart Router Overview
1.1.1 Backplane
8665 Smart Router uses a dual backplane architecture, which allows that all the cards are accessible
from the front panel. The backside of the subrack has a metal cover and all the interface connectors
are located on the front side. The signal backplane itself is passive and only provides connectors
and signal paths for high speed data packet transfer. Power distribution and low speed signaling
among the cards is handled by a separate backplane. The power backplane contains some passive
components for line termination, signal integrity purposes and the identification EEPROM.
The backplane data transmission architecture is based on differential signals in which the switch
cards are the center points for a dual star topology in a redundant configuration. There is also a
separate internal communication dual star bus topology between the units in the NE. This separate
control bus assures that the NE internal control is not lost even if the forwarding plane network
processors have problems. The other buses are power, synchronization (clock), fan module control
and unit presence busses.
20
1 8665 Smart Router Overview
There are 8 slots in 8665 Smart Router, of which 6 (slots 2...4 on the left side and slots 11...13 on the
right side) are available for the line units with user traffic interfaces. The central slot, divided into
two slots (7 and 8) is reserved for the two switch units, SU1s.
At least one SU1 must be installed into one of the switch slots for the 8665 Smart Router to be
operational. Equipping the second slot with an SU1 is highly recommended, although the need for it
depends on protection requirements. All units are hot-removable and hot-insertable.
Besides the physical slots, logical slots 1 and 14 are reserved for the control functionality running on
the line units. Refer to chapter Control Functionality (CU) for more information.
8665 Smart Router line unit LU1 has the following interfaces:
• 1x100GE (CPF2) + 24x1/10GE (SFP+/SFP) with two user selectable operating modes:
• 1x100GE (CPF2) + 14x1/10GE (SFP+/SFP)
• 24x1/10GE SFP+/SFP
LU1 contains the following functional features:
21
1 8665 Smart Router Overview
LU1 Features
Feature LU1 Support
Forwarding Throughput capacity 130 Gbps/s with one
operational SU1
200 Gbps/s with two
operational SU1s
IPv4 routing Supported
MPLS switching Supported
Ethernet MAC switching Supported
Services IP VPN Supported
Pseudowire attachment circuits Supported
Traffic management 7 DiffServ traffic classes (EF, AF, BE, CS) Supported
7 queues per port Supported
VLAN queuing Supported
Ingress packet policers Supported
RED/WRED queue management Supported
Tail drop queue management Supported
Strict priority and WFQ scheduling Supported
Egress port queue shaping —
VLAN shaping Supported
Synchronization Synchronous Ethernet Supported
Protection Ethernet Link Protection (ELP) Supported
[IEEE 802.1AX] Ethernet link aggregation Supported
(intra-IFM) (LAG)
Equal Cost Multipath (ECMP) Supported
Fast Reroute (FRR) —
Virtual Router Redundancy Protocol (VRRP) Supported
Ethernet Pseudowire redundancy Supported
Statistics Port and layer 2 protocol statistics Supported
IP and MPLS statistics —
VLAN statistics Supported
OAM [IEEE 802.1ag]/[Y.1731] Ethernet OAM Supported
Miscellaneous L3/L4 access lists Supported
Power consumption measurement Supported
The control functionality (CU) in 8665 Smart Router is run on one or two line units, depending on
the required level of redundancy and the amount of units present in the network element. Note that
the CU on the line units is a completely separate running protected process.
22
1 8665 Smart Router Overview
Currently, the control functionality can be run only on the line units in slots 2 and 13, respectively
the leftmost and rightmost line units in the network element. When both units in slots 2 and 13 are
installed, the network element is fully redundant.
Note that the timing and alarm interfaces should be only used from slots 2 and 13.
8665 Smart Router switch unit SU1 is used for packet switching inside the network element. SU1 has
two separate switches. The main data plane switch, which has a capacity of 900 Gbps, and a separate
control plane switch with a capacity of 90 Gbps. Although almost full data plane capacity can be
reached with one SU1, it is strongly recommended to use two SU1s in a redundant configuration, as
the traffic load will be shared between the two SU1s to enhance throughput and latency1.
1.1.3 Cooling
1When there is only one SU1, packet header terminations and additions, packet size and other factors affect the throughput.
23
1 8665 Smart Router Overview
8665 Smart Router is a forced convection-cooled equipment. Fresh air is taken from the
bottom-front of the subrack and funneled through the units and the outlet air is led to the top-back.
Forced cooling is needed to dissipate the generated heat load and to maintain the components
within their operating limits.
Three fan modules, located below the card shelf, blow air through the units. One module consists
of three parallel fans. If one of the fans fails, the other eight will maintain adequate cooling for
a limited time.
The control functionality on LU1 monitors and controls the equipment temperature by adjusting
the fan rotation speed via the backplane. The rotation speed control of the fans is based on the
temperature values measured from the components on the units in the NE. The 8665 Smart Router
fan module supports 16-step fan speed control. At start-up the fans are running at full speed until the
equipment is booted up and able to monitor the card temperatures. The operating temperature of a
unit measured by any sensor is targeted to be below +67° C/+152.6° F. If any sensor exceeds that
value, the rotation speed of the fans will be adjusted to maintain it.
There are several temperature measuring sensors on the line unit and switch unit. Some of them
measure the internal temperature of the components, while others measure the line unit temperatures
in different locations. Each sensor has its own threshold for high temperature warning and critical
temperature alarms. A high temperature warning is raised when the measured sensor temperature
exceeds its time-conditional threshold for over 15 minutes and immediately when the high
unconditional threshold is exceeded. The high temperature warning indicates that the operating
ambient temperature is high and about to exceed the allowed operating range. If the warning occurs
and the equipment is not used in high ambient temperature, it may be advisable to change the air
filter and check that there are no obstacles preventing smooth air flow. When operating at sea level
and the air filter is clean, this warning will occur at ambient near +45° C/+113° F.
If the data plane switch component temperature is exceeded the data forwarding for that SU1 is
disabled to cool down the unit, but the SU1 will still switch the NE internal communication to
protect the NE internal communication integrity.
LU1 will go to power-save mode, if the critical time-conditional threshold is exceeded for over 15
minutes or immediately, if the unconditional threshold is exceeded. LU1 will stay in power-save
mode for about 8-9 minutes before it checks if the conditions are acceptable.
24
1 8665 Smart Router Overview
Air Filtering
The air filter prevents dust from entering the subrack and keeps the cards clean in order to maintain
adequate cooling. The air filter is located in front of the fan modules in 8665 Smart Router subrack.
All empty unit slots must be shielded with a cover plate to enhance cooling, prevent EMC emissions
and dust entering the subrack.
The fan modules and air filter can be replaced on the fly without disturbing the data traffic through
the NE. Refer to the 8600 Smart Routers Hardware Installation Guide for detailed instructions.
Fan Module
One fan module has three brushless fans, three fan drive circuits and a common control logic
including a watchdog. Fuses protect the input against over-current, similarly the fan drive circuits
have short circuit protection and limited output current in case of a fan failure. The control
functionality (CU) is able to control and monitor the operation of the fan module. If the CU fails to
control the module, the watchdog will set the fan speed to the maximum.
The 8665 Smart Router can be powered with a power input module PIM with support for -48
Vdc nominal input voltage.
The NE has two slots for PIMs. Redundant power feeding is achieved by installing a PIM in both
power module slots.
25
1 8665 Smart Router Overview
The typical and maximum power consumption values of the 8665 Smart Router units and modules
are defined in the 6 Technical Specifications. These values are stored on the non-volatile memories,
EEPROMs, of the units and modules. An estimation of the power consumption of a particular NE
installation is calculated as a sum of all the units and modules in the network element.
The network element software automatically calculates the sum of the power consumption values
from the EEPROMs of the installed units and modules in the network element. The software then
compares the power consumption sum with the maximum permissible power consumption or
cooling capacity (smaller value used by software) for the network element. If the maximum
permissible power is exceeded, an alarm will be raised and no new units will be accepted into the
hw-inventory and thus the usage of the units will not be allowed. Currently no such configurations
exist for 8665 Smart Router.
• The sum of averages of the typical and maximum power consumption values for modules and
cards in LU1 and SU1 in 8665 Smart Router,
• The sum of maximum power consumption values of the Fan Modules,
• For power input modules (PIM), add the average of the typical and maximum power consump-
tions of PIM to the NE power consumption sum only once, even though there are two PIMs in
the NE.
Power consumption values of the network elements are needed for different purposes in central
offices and other telecommunications sites. To properly dimension systems and resources to support
the network elements in a sufficient but economically feasible way, the users of the 8600 products
may consider for what purpose they need the power consumption values and decide which value
they want to use for which purpose. The sum of typical power consumption values of the cards
and modules populated in the NE presents the typical power consumption of the NE in most of the
cases. The way the element software calculates the power consumption of the NE (described above)
is a good value for the maximum power consumption with quite high probability. The sum of the
maximum power consumption values of the cards and modules is the theoretical absolute maximum
power consumption value for the NE, which should never realize with 8665 Smart Router.
26
1 8665 Smart Router Overview
While dimensioning different things at the central offices and other telecommunications sites,
the information about the power consumption of the NE or the current drawn by the NE may be
needed. Cooling of the telecommunications site might be a good example for the former case and
dimensioning of the cables and circuit breakers for the latter. The maximum current for the NE can
be calculated by dividing the suitable evaluated maximum power consumption of the NE for the
purpose by the lowest specified battery voltage for the NE.
1.4 Synchronization
8665 Smart Router has a common timing generator. It is especially needed when synchronous
Ethernet interfaces are in use. The generator is located on every LU1, and the timing reference
signals are distributed to every unit in the NE via the backplane.
The Timing Module provides a Synchronous Equipment Clock (SEC) or Stratum 3 generator
complying with the relevant requirements. Typically, the NE is synchronized with a clock derived
from any of the following input signals:
For details of the synchronization functionality please refer to 8600 Smart Routers
Synchronization Configuration Guide.
The selected reference signal must be originated from an equipment having, at least, the SEC quality
clock, that is, the reference signal quality must be as defined in [ETS 300 462-3] and [EN 300
462-5-1] or [GR-253-CORE]. This means, for instance, that a 2048 kHz signal which complies with
[G.703] jitter and wander requirements may not be used as a reference.
When 8665 Smart Router is equipped with one LU1, the NE has one station clock interface (SCI),
i.e. one input and one output port. With a redundant configuration both ports are duplicated and 1+1
protection is provided. The protecting port has a common parameter set with the protected port.
Both LU1 drive their own station clock output (SCO) port separately.
8665 Smart Router can provide protection via the control functionality (CU). When two equal LU1
are installed in slots 2 and 13, 1+1 protection is provided for the NE control functionality and
for synchronization, if present in the line unit. At the same time, the power feed functionality
utilizes a protection where the input with a higher voltage feeds the NE. A critical failure in the
active LU1, where the CU is running, will trigger an automatic switchover to a redundant LU1.
On the other hand, a failure in the NE power distribution will not cause a switchover because the
DC inputs are shared continuously.
8665 Smart Router LU1 does not have a dedicated MFE (Management Fast Ethernet) port, instead
any available Ethernet port can be used as management interface. If this port needs to be protected,
ELP should be used to protect it.
27
1 8665 Smart Router Overview
Ethernet Link Protection (ELP) or [IEEE 802.1AX] Ethernet Link Aggregation (LAG) are applied
for protecting Ethernet physical interfaces. For more information see 8600 Smart Routers Ethernet
Configuration Guide.
8665 Smart Router provides two slots for the switch units. With one switch unit the network element
is not redundant in terms of traffic switching. With two switch units the network element is fully
redundant on the data and control plane switching. Also traffic is load shared to both switch units to
enhance the QoS behavior and reduce switchover time in case of failure.
Static terms:
28
2 Line Unit (LU1)
2.1 Overview
LU1 is a single-slot unit designed for networks requiring high switching capacity and multiple high
speed Ethernet interfaces for enabling smooth technology and capacity migration driven by HSPA
and LTE growth. The main applications of LU1 are MPLS trunking over the 10/100-Gigabit Ethernet
links in mesh or ring topology, and IP or IP VPN service endpoint, for example at the RNC site.
LU1 combines 130 Gbp/s with a single operational SU1 and 200 Gbp/s with two operational SU1s
switching capacity, and two operating modes with the following port configuration options at
wire speed:
The maximum configuration of six LU1 can be achieved either with one or two 8665 Smart Router
DC48 power input modules in the 8665 Smart Router subrack.
Each LU1 has a direct connection via the backplane to both switch units in 8665 Smart Router.
• CPU subsystem
• SD-card for application software, field upgrade possible
• Layer 2 and layer 3 packet switching, packet forwarding, packet filtering and traffic management
functions (NPU subsystems)
• High speed backplane data links with switch units
• Four LEDs showing card status
• External alarm and timing interfaces
• Operation voltage monitoring and card temperature measurement
• I2C bus for accessing devices such as EEPROMs, A/D converters and temperature sensors
• Serial EEPROM for the factory parameters
• Reference and equipment clock (SEC) selector and monitoring
29
2 Line Unit (LU1)
2.3 Operation
The function of LU1 is to perform layer 2 and layer 3 packet switching, packet forwarding, packet
filtering and traffic management functions. The CPU subsystem is used to control LU1 functionality.
The CPU subsystem uses a high performance 64-bit RISC processor with the following memories:
• DDR3 DRAM
• Application FLASH (SD-memory card)
• Boot FLASH
The application software is stored in FLASH memory. Thus, it is possible to update the software
on the field when new software feature packs become available. Similarly, the card and interface
parameters are stored in FLASH, so those are restored after reset.
30
2 Line Unit (LU1)
PLD
I2C
I2C bus and switches are used for accessing devices such as EEPROMs, A/D converters and
temperature sensors.
RTC
The real time clock has backup for short power breaks. The time is kept for at least 20 hours (at
20º C/68º F).
A/D Converter
There is an analog-to-digital converter on the baseboard. It is used for measuring and monitoring
operating voltages and temperatures.
There is one dedicated general alarm output. There are also four alarm inputs.
The NPU subsystem performs layer 2 and layer 3 packet switching, packet forwarding, packet
filtering and traffic management functions. For data buffering and other functions, the NPU uses
DDR3 as well as TCAM memories.
The FPGA subsystem implements the timing logic for the timing block and many miscellaneous
control functions.
The timing block is a Network Element Clock generator with a station clock interface. The
station clock interface supports a [G.703] 2048 kHz synchronization interface or an interface with
Synchronization Status Messages.
The 8600 Smart Routers Network Element Clock complies with SEC [G.813] and Stratum 3
generator [GR-1244-CORE]. The functional modelling is specified in [ETS 300 417-6-1] and
[G.781].
31
2 Line Unit (LU1)
The station clock input/output interface is on the front plate of the timing block. Depending on the
user needs, either coaxial or differential cabling can be used with a corresponding connector, i.e.
SMB or RJ-48c. The front panel has also the Time of Day and Pulse Per Second (PPS) interfaces in
an RJ-45 connector. The Time of Day and PPS interfaces use a point-to-point ITU-T V.11 interface.
The port must be connected to the same type of port with proper cable, otherwise network
element functionality may be affected or physical damage may occur. Long cables should be
terminated properly to reduce interference.
32
2 Line Unit (LU1)
Pin # Description
5 Output B-wire (tip)
6 Not connected
7 Not connected
8 Not connected
Pulse per Second and Time of Day Interface Signals of RJ-45, Female 8 Pins
Pin # Description
1 Pulse per second cable compensation negative,
RS-422 level signal
2 Pulse per second cable compensation positive,
RS-422 level signal
3 Pulse per second negative, RS-422 level signal
4 Ground
5 Ground
6 Pulse per second positive, RS-422 level signal
7 Time of Day negative, RS-422 level signal
8 Time of Day positive, RS-422 level signal
Near End Unit Remote End Unit Remote Device Raw Bandwidth
LU1 SU1 Switch Fabric FPGA 130 Gbp/s with one
operational SU1
200 Gbp/s with two
operational SU1s
LU1 SU1 Control ethernet switch 10 Gbp/s
LU1 contains an integrated power supply (DC/DC converters) on board. It generates all the voltages
needed within different blocks. The input voltage is fed by either of the PIMs (redundancy with
two PIMs). The generated output voltages are galvanically isolated from the battery voltage. LU1
also has polarity protection for input voltages.
During boot-up, LU1 performs self tests to verify that the system operational status is nominal.
33
2 Line Unit (LU1)
2.4 Interfaces
When selecting between the 1G/10G modes it has to be done in pairs, i.e. M1/0 and M1/1,
M1/2 and M1/3 etc.
For M2/4...13 ports the maximum link span with 10GBASE-ZR SFP+ optics is ~65km depending
on the link conditions, all other 10GBASE-R ports support the full link span.
34
2 Line Unit (LU1)
For more information on CFP2, SFP+ and SFP transceivers approved by Coriant and the Receive
(Rx) and Transmit (Tx) directions in them, see 8600 Smart Routers Hardware Installation Guide.
35
2 Line Unit (LU1)
This port is for future use and will become operational in a future software release.
The asynchronous serial interface is according to [EIA/TIA-232-E]. The baud rate for this interface
is 38400 bps. The connector type is RJ-45, female, with 8 pins.
The port must be connected to the same type of port with proper cable, otherwise network
element functionality may be affected or physical damage may occur. Long cables should be
terminated properly to reduce interference.
36
2 Line Unit (LU1)
The external alarm interface is used for NE alarms and user configurable output and inputs. It
provides output with solid state relay contacts and inputs for external voltage free contacts, for
example relays. Inputs can also be voltage driven.
The user configurable output is similar to conventional relay and have three pins; common (Com),
normally closed (NC) and normally open (NO) pins. The configuration is carried through CLI or
8000 Intelligent Network Manager.
Fig. 9 Input
In addition to the outputs, there are four user configurable inputs which consist of comparator and
protecting circuits. When the input is connected below the threshold voltage, for example, to ground
by an external device (relay), the state of the input is considered to be closed, otherwise open.
The user is able to configure a possible consequence action if the input state changes, i.e. what
kind of an alarm is risen. A typical application would be, for example, site intrusion detection or
site power supply problems.
The port must be connected to the same type of port with proper cable, otherwise network
element functionality may be affected or physical damage may occur. Long cables should be
terminated properly to reduce interference.
37
2 Line Unit (LU1)
There are four LEDs to indicate the LU1 status and one for the power OK status.
There are two LEDs to indicate the LU1 Ethernet port status.
38
2 Line Unit (LU1)
2.7 Cabling
Cabling depends on the SFP, SFP+ or CFP2 type on the optical interfaces, see chapter Pluggable
Transceivers in 8600 Smart Routers Hardware Installation Guide.
See more on laser safety in chapter Pluggable Transceivers in 8600 Smart Routers Hardware
Installation Guide.
Check that the operational temperature range of the SFP/SFP+/CFP2 module is suitable for
the installation environment. Note that the temperature of the SFP/SFP+/CFP2 case can be
approximately 15 degrees higher than the ambient temperature. For more information on the
allowed SFP/SFP+/CFP2 case temperature range see chapter Pluggable Transceivers in 8600
Smart Routers Hardware Installation Guide.
It is important to ensure that adequate cooling is used when an LU1 is installed in a subrack. LU1
has temperature sensors that monitor the unit temperatures during operation. LU1 can endure a
single fan failure but if two or all the fans of one fan module fail, the LU1 located above it will go to
power-save mode after 6 minutes.
The high temperature warning will be raised when the card is operated in high ambient temperature.
This occurs at around +45° C/+113° F ambient. Another reason why this warning can be active is if
the air flow is decreased, which can be caused by a dirty air filter in the subrack. There are also
critical temperature limits which will cause the cards to go to power-save mode if they are exceeded.
All empty line unit slots have to be shielded with blank cover plates.
39
3 Switch Unit (SU1)
3.1 Overview
SU1 provides 900 Gbps switching capacity for the network element and also control channel
Ethernet switching at 90 Gbps.
In 8665 Smart Router the maximum configuration of two SU1s is supported, but the network
element is fully functional with one SU1.
Each LU1 has a direct connection via the backplane to both switch units in 8665 Smart Router.
• CPU subsystem
• SD-card for application software, field upgrade possible
• Switch matrix FPGA
• Ethernet control switch
• Operation voltage monitoring and card temperature measurement
• I2C bus for accessing devices such as EEPROMs, A/D converters and temperature sensors
• Serial EEPROM for the factory parameters
3.3 Operation
The function of SU1 is to perform packet switching between the line units on data and control plane
levels. Control and data plane traffic is separated inside the chassis and they cannot disturb each
other in any situation. The CPU subsystem is used to control the switch unit functionality.
40
3 Switch Unit (SU1)
The CPU subsystem uses a high performance 64-bit RISC processor with the following memories:
• DDR3 DRAM
• Application FLASH (SD-memory card)
• Boot FLASH
The application software is stored in FLASH memory. Thus, it is possible to update the software
on the field when new software feature packs become available. Similarly, the card and interface
parameters are stored in FLASH, so those are restored after reset.
PLD
I2C
I2C bus and switches are used for accessing devices such as EEPROMs, A/D converters and
temperature sensors.
41
3 Switch Unit (SU1)
RTC
The real time clock has backup for short power breaks. The time is kept for at least 20 hours (at
20º C/68º F).
A/D Converter
There is an analog to digital converter on the baseboard. It is used for measuring and monitoring
operating voltages and temperatures.
The FPGA subsystem implements the switch matrix functionality for the NE at 900 Gbps.
The control Ethernet switch is used for NE internal communication and it is fully separated from
the normal data plane.
SU1 contains an integrated power supply (DC/DC converters) on board. It generates all the voltages
which are needed within different blocks. The input voltage is fed by either of the PIMs (redundancy
with two PIMs). The generated output voltages are galvanically isolated from the battery voltage.
SU1 has a polarity protection for wrong polarity.
During boot-up, SU1 performs self tests to verify that the system operational status is nominal.
42
3 Switch Unit (SU1)
There are four LEDs to indicate the SU1 status and one for the power OK status.
43
3 Switch Unit (SU1)
44
4 Power Input Module
4.1 Overview
The DC48 power input module for 8665 Smart Router offers -48 Vdc supply interface. 8665 Smart
Router subrack provides two power input modules (PIM) on the front side of the NE. Two power
input modules enable redundant power feeding. The nominal input voltage is -48 Vdc. The -48 Vdc
output of the PIM is routed to the backplane for the use of line units, switch units and fans.
4.2 Operation
The input voltage is fed through the input fuses and filters to the backplane. The PIM also includes
transient overvoltage protection. Redundancy is realized by using two PIMs in the NE. There is no
active current sharing between the two PIMs. However, in the case of equal input voltages at input
connectors the current will be divided rather equally between the two PIMs. One PIM is able to
supply the whole current required by the 8665 Smart Router subrack in case of failure in other PIM.
45
4 Power Input Module
The input connector is located on the front side of the PIM. The -48 Vdc output voltage and signal
connector is located on the back side of the PIM.
On the PIM there is a voltage monitor for input voltage detection. If the input voltage after the
fuse is missing or too low, an alarm is forwarded to the CU on the LU1, and a LED indicates the
input voltage status.
4.5 Cabling
The PIM can be used with normal copper power cables as screw terminals are used. The maximum
conductor cross section is 25 mm2 (solid), 16 mm2 (stranded) and 16 mm2 (with ferrule). The
router can be wired with either single power cable pair or two pairs of cables if thinner cable is
preferred in the installation.
Also a grounding cable with the same or thicker cross-sectional area than the power cable must
be used with the 8665 Smart Router subrack with PIMs installed; that is, at least 16 mm 2
(approximately 5 AWG) or 25 mm2 (approximately 3 AWG). For more details on power and
grounding cabling, please refer to 8600 Smart Routers Hardware Installation Guide.
46
5 Pluggable Transceivers
5 Pluggable Transceivers
For detailed information on the transceivers approved by Coriant supported in 8600 Smart Routers,
refer to 8600 Smart Routers Hardware Installation Guide.
47
6 Technical Specifications
6 Technical Specifications
8665 Smart Router subrack 445 x 666 x 445 mm (w x h x d), width is without the integrated
dimensions side adapter front flange, the width with the integrated side adapter
front flange is 483 mm.
17.51 x 26.22 x 17.51 in (w x h x d), width is without the integrated
side adapter front flange, the width with the integrated side adapter
front flange is 19.01 in.
Standard 19-inch rack or cabinet mounting.
8665 Smart Router subrack 25 kg/55.11 lbs without cards.
weight 34 kg/74.95 lbs with two DC48 Power Input Modules (PIMs) and
three fan modules
Blank cover plate weight (only 81.86B-LUBLANK-R6 (line unit blank cover with air guide) 0.24
for LU1) kg/0.52 lbs
Safety compatibility [EN 60950-1:2006].
[IEC 60950-1:2005].
Electromagnetic compatibility [EN300 386 V1.6.1]
[FCC 47 CFR Part 15, Subpart B] Class A
Installation environment: telecommunication centre
Climatic/mechanical Storage:
compatibility [ETSI EN 300 019-1-1] Class 1.1
Temperature: -5° C to +45° C (+23° F to +113° F).
Transportation:
[ETSI EN 300 019-1-2] Class 2.3
Temperature: -40° C to +70° C (-40° F to +158° F)2
Operating Conditions:
[ETSI EN 300 019-1-3] Class 3.23
Temperature: -5° C to +40° C (+23° F to +104° F).
Relative humidity: 5% to 95%.
Usage altitude 60 m below sea level (106 kPa air pressure) to 3000
m (70 kPa).
The operational temperature range of the whole network element is determined on the
narrowest operating temperature of the interface modules and or SFP/SFP+/XFPs used.
48
6 Technical Specifications
Check that the operational temperature range of the SFP/SFP+/XFP module is suitable for
the installation environment. Note that the temperature of the SFP/SFP+/XFP case will be
approximately 15 degrees higher than ambient temperature. For more information on the
allowed SFP/SFP+/XFP case temperature range see chapter Pluggable Transceivers in 8600
Smart Routers Hardware Installation Guide.
4Chassis equipped with LU1 and SU1 cards does not use the full 85A, but in the worst conditions (temperature, components, voltage) up to 45A.
49
6 Technical Specifications
LU1 1-port 100GE + 24-port 1/10 Gigabit Ethernet Line Unit LU1
(1x100GBASE–R / 24x10GBASE-R/1000BASE-X, note the
different operating modes as all ports are not usable at the same time)
Timing block: ETSI SEC or ANSI Stratum 3 timing reference,
SyncIn/Out (RJ-48c and SMB connectors), PPS (RJ-45 connector,
point-to-point ITU-T V.11 interface), E1, 2MHz, T1 SF, and T1 ESF
interfaces.
Management interfaces: RS-232 serial (RJ-45 connector) and
Ethernet (RJ-45 connector) ports.
External Alarm In/Out interface (RJ-45 connector).
Runs routing and label distribution protocols via the control
functionality (CU).
Unit optionally protected (redundant) - synchronization management
and routing protocols.
SU1 Switch unit.
Coriant recommends that two SU1s are always used.
Packet buffer size LU1: 2 GBytes
Performance HW-based architecture guarantees forwarding at wire speed both for
IP and MPLS traffic under any condition.
Throughput:
• 130 Gbp/s bidirectional per LU1 with one operational SU1
• 200 Gbp/s bidirectional per LU1 with two operational SU1s
• 780 Gbp/s bidirectional per subrack assuming simple IMIX LU1
with one operational SU1
• 1200 Gbp/s bidirectional per subrack assuming simple IMIX
LU1 with two operational SU1s
2000 VRFs per LU1 and subrack.
440K IPv4 routes or 440K VPN routes with LU1.
16000 PWE3 tunnels per subrack.
8000 VLANs per LU1.
64 Link Aggregation groups.
16000 ACL entries per LU, 2000 ACL lists per subrack.
2000 Virtual Switching Instances (VSI) with LU1.
500 000 MAC address table with LU1.
IPv4 and MPLS routing and Static routing, OSPF-TE [RFC3630], IS-IS-TE [RFC3784],
label distribution protocols and (MP)-BGP4 [RFC1771] and [RFC2858], LDP [RFC3036],
functionality RSVP-TE [RFC3209].
IPv4 loadbalancing to RSVP-TE LSPs.
Equal Cost Multi Path (ECMP) routing.
Integrated Routing and Bridging.
IPv4 header compression [RFC2507].
L3 VPN technologies IP VPNs based on [RFC4364].
PWE3 functionality Ethernet raw mode PWE3 [RFC4448].
Ethernet tagged mode PWE3 [RFC4448].
Multi-segment pseudowires [RFC6073].
Pseudowire redundancy [draft-ietf-pwe3-redundancy].
VCCV BFD.
VCCV LSP ping.
Drop counters and history records for Layer 2 pseudowire.
50
6 Technical Specifications
51
6 Technical Specifications
52
6 Technical Specifications
DC48 Power Input Module (PIM) for 8665 Smart Router Technical Specifications
Dimensions 45.75 x 112 x 385.75 mm (w x h x d)
1.80 x 4.40 x 15.18 in (w x h x d)
Weight 1.4 kg/3.08 lbs
Input specifications -48 Vdc nominal input voltage (-40 ... —60VDC)
85 A input current
3400 W maximum power (for the whole NE)
Power consumption Typical 35 W
Maximum 62.5 W
Alarms Battery voltage monitoring
53
6 Technical Specifications
54
End of Life Treatment
Do not dispose electrical and electronic equipment with unsorted municipal and household waste.
Please consult your local authorities for suitable disposal method for electronic and electrical waste.
Correct handling of the disposed equipment contributes to reuse, recycling and other form of
recovery to protect the environment.
The equipment is marked with the figure shown below, to indicate that the equipment must be
collected separately.
55