Sei sulla pagina 1di 2

Speedswitch

Underspeed Motion Monitor


Monitors Rotating Machinery for Dangerous Underspeed Conditions

Optional Tachometer

Totally sealed: To IP67 with simple “magnetic calibration”

Low cost, maintenance free: Unit is solid state with no moving parts
for virtually limitless life.

Dual Set Points: Ten and twenty percent underspeed.

“Non-contact” Sensor requires no contact with monitored machinery.

Outputs: Tachometer and relay contacts

Applications: Conveyors, elevators, mixers, fans, pumps, grinders and


all mechanical handling systems.

Your Material Handling Specialists!


4B COMPONENTS LIMITED
7 2 9 S a b r i n a D r i v e • E a s t P e o r i a , I l l i n o i s 6 1 6 1 1 U S A • Te l e p h o n e 3 0 9 . 6 9 8 . 5 6 1 1 • F a x 3 0 9 . 6 9 8 . 5 6 1 5
h t t p : / / w w w. g o 4 b . c o m E-Mail: go4b@aol.com
Speedswitch Underspeed Motion Monitor
Operation
An inductive sensing device located in the nose of the M800 enclosure will detect a metal target. This target can be an existing
bolt head or device attached to a shaft. Ideally the target should be ferrous metal but non-ferrous metal will be detected at a short-
er range. A signal is generated by this target on each revolution of the shaft. The M800 is then set to the normal machine RPM by
calibrating with the magnet provided. If the shaft speed falls to 10% or 20% below normal RPM, the M800 provides output sig-
nals via relays for control purposes such as alarm and/or shutdown. An opto-isolated output is provided for tachometers, PLCs
and speed displays.

Dimensions 1
⁄2” NPT* Connections
conduit entry
Black/Brown Brown
19⁄16” L
(40) Black/Red 10% Supply
Blue
N

19⁄16” 37⁄8” 13
⁄16”
(40) (98) (21) Black/Orange Pink + Tacho
8 Output
6 ft. long cable Black/Yellow 20% (insulate
White -
5 connections
13⁄16” if not used)
(30)
The diagram above shows the state of the internal con-
tacts when power is applied to the M800. See installation
13⁄16” 211⁄32” 4 x 15⁄64” fixing holes (M6) manual for onsite wiring procedure. The 10% contact clos-
(30) (60) es when the speed falls below 10% of set speed. The
20% contact opens when the speed falls below 20% of
Technical Specifications set speed or power supply is interupted. The unit can be
Supply: 220VAC 50/60 Hz
110VAC 50/60 Hz
24VDC
}Specify when ordering
used with or without the tacho output. High clarity 6-digit
vacuum fluorescent tacho displays are available for con-
nection to the unit.
Supply Tolerance -15% to +7.5%
Consumption: 6VA
Fuse: Supply to be fused at 5A Max.
Speed Range: 10-3600 PPM (pulses per minute)
Outputs: 1. Normally open contact closing
(powered up) when speed falls by 10%
2. Normally closed contact opening
when speed falls by 20%
3. Tacho output opto-isolated 30v, 100mA
Contact Rating: 3A 240VAC non-inductive “Whirligig”
Start-up Delay: User selectable 0-30 seconds
Sensing Range: 11
⁄32” (9mm) max. ferrous
7
⁄32” (6mm) max. non-ferrous
Calibration By “magnetic swipe”
Enclosure: Molded enclosure PC/ABS
Protection: FM and CSA approved. Hazardous conditions.
Class II Div 1 Groups E,F,G
IP67 dust and watertight.
Weight: 1.5 lbs (0.525 kg)
Accessories: MTG4 Target Disk*
H350120 “Vibratone” Alarm Horn
TACH1V5 Tachometer Display
WGI-4B “Whirligig” target,
mounting bracket and guard. Optional Tachometer
* Exposed rotating targets must be
protected with an approved guard.

Brochure information subject to change or correction. January 2000

4B COMPONENTS LIMITED
7 2 9 S a b r i n a D r i v e • E a s t P e o r i a , I l l i n o i s 6 1 6 1 1 U S A • Te l e p h o n e 3 0 9 . 6 9 8 . 5 6 1 1 • F a x 3 0 9 . 6 9 8 . 5 6 1 5
h t t p : / / w w w. g o 4 b . c o m E-Mail: go4b@aol.com