Sei sulla pagina 1di 2

UL Listed

IMC & EMT Pipes


and Fittings

UNIVER (IMC) Intermediate Metal Conduit is precision


manufactured for economical protection and long lasting value for
electrical raceway system and wiring installations. It is lighter in weight,
but as strong as rigid, manufactured and processed as to ISO 9001 and
UL standards with technologically advance and well-equipped facilities,
of good quality and competitive price advantage. Also conveniently
offers all related fittings like couplings, locknut and bushings, elbows,
connectors and strut clamps, etc.
Today, as it is engaged in manufacturing highest quality Conduits
and Fittings and other materials such as EMT, Elbows, conduit straps
and hangers, malleable iron beam clamp and other related electrical
UL File Number E365150/E362849 products, most of the products have UL Certificate of Compliance.
UL File Number E477629/E362923

Product lines
IMC CONDUIT *UL Listed EMT PIPES
*UL Listed
*Made from highest quality *Made from finest carbon
prime steel steel coil according to ANSI
*Threaded both ends with *C80.3 and UL797 standards.
one coupling and plastic cap. *Hot dip galvanization,
*Hot dip galvanization, zinc plated
zinc plated *UL / CSA *Corrosion resistance
*UL / CSA
IMC COUPLING EMT COUPLING
*UL Listed
*Threaded couplings are used *UL Listed
to join two lengths of *Set screw type coupling are
threaded IMC Conduit. used to join two lengths of
*Threaded both ends with threadless EMT Conduit
one coupling and plastic cap. *Concrete-Tight
*Hot dip galvanization, *Steel
zinc plated *UL / CSA *UL/CSA

IMC ELBOW EMT CONNECTOR *UL Listed


*UL Listed *Set screw type connectors are
*Galvanized Steel used to secure and terminate
*Zinc Plated threadless EMT to a steel outlet
EXCLUSIVELY *UL / CSA
*Steel 90 degree rigid elbows are
box or metal enclosure.
DISTRIBUTED BY: used to connect steel rigid conduits
*Concrete-Tight
*Steel
together allowing 90 degree bends. *UL/CSA

*Insulated Metallic Conduit bushings


INSULATED METALLIC **UL Listed for grounding
are used on the end of IMC Conduits & IMC LOCKNUT
CONDUIT BUSHING other threaded connectors to provide a 600V or less.
smooth well rounded bearing surface to *Use to secure threaded
Available at: protect wires /cables. conduits or connectors.
GLITZ ELECTROBUILDERS CO., INC. *Thermoplastic liner rated 105 C *UL listed, concrete
514 Ayala Blvd., Ermita, Manila *Malleable iron / Zinc Die-Cast tight when taped.
Tel. #: 5271413, 527-6653, *UL 514B CSACC22.2 No. 18 *UL standard 5148
527-7671 to 80 NEMA FB- 1 NEC Art. 345 & 346
*UL / CSA
*UL / CSA

For inquiries, TWO GANG WEATHER PROOF SQUARE BOX WITH COVER RECTANGLE STEEL BOX (UTILITY BOX)
Please contact: *UL Listed
*UL Listed
*Aluminum Die-Cast
_____________________________ *4”x2”
*4”x4”
*1-7/8” depth
*UL514A, CSA C22.2 No.18.1-04
*1/2” and ¾” Knockouts
___________________________ *Zinc Plate
*13 Cubic inch capacity
*UL/CSA
UL Listed EXCLUSIVELY DISTRIBUTED BY:
IMC & EMT Pipes
and Fittings
UL File Number E365150/E362849
UL File Number E477629/E362923

Quality: Dimension and Weight Chart of the Intermediate Metal Conduit (IMC)
Most of our product are UL
Metric Acceptable length of Weight of 10 unit
approved, we make them based Trade
Designato
Thread
finished conduit lengths with
Nominal Outside Nominal Inside Nominal Wall
Size Inch Diameter Diameter Thickness
on UL Standard. Our r without coupling coupling
+/- 1/4 +/-
Manufacturing Policy is to make ft. in. 6mm lb. kg. in. mm. in. mm. in. mm.
the products of the best possible 1/2 16 14 9 11 1/4 3030 62 28.12 0.815 20.7 0.66 16.76 0.078 1.97
quality with economy in price. 3/4 21 14 9 11 1/4 3030 84 38.1 1.029 26.14 0.869 22.07 0.083 2.1
Accordingly, we have adopted 1 27 11 1/2 9 11 3025 119 53.98 1.29 32.77 1.105 28.07 0.093 2.35
1 1/4 35 11 1/2 9 11 3025 158 71.67 1.638 41.59 1.448 36.77 0.095 2.41
quality levels in a manner, so
1 1/2 41 11 1/2 9 11 3025 194 88 1.883 47.82 1.683 42.74 0.1 2.54
that our products meet & exceed 2 53 11 1/2 9 11 3025 256 116.12 2.36 59.93 2.15 54.6 0.105 2.67
required performance and safety 2 1/2 63 8 9 10 1/2 3010 441 200.04 2.857 72.57 2.557 64.95 0.15 3.81
parameters. 3 78 8 9 10 1/2 3010 543 246.3 3.476 88.29 3.176 80.67 0.15 3.81
3 1/2 91 8 9 10 1/4 3005 629 285.31 3.971 100.86 3.671 93.24 0.15 3.81
4 103 8 9 10 1/4 3005 700 317.52 4.466 113.44 4.166 105.82 0.15 3.81
Plating:
By employing sophisticated *Note:
procedures like electro zinc * Figures are the average of the maximum and minimum dimensions as given in UL 1242
plating, cold galvanizing, and ** Calculated from nominal outside diameter and nominal wall thickness.
Steel Intermediate Metal Conduit is manufactured to produce a 10ft. (3.05m) length of conduit when a standard coupling is
others. We ensure the finished attached.
products durable effective and
fit-for-purpose.
Dimension and Weight Chart of the Electrical Metallic Tubing (EMT)
Testing: Per Piece Per 100 ft. Per Hex Bundle
Ring gauge, plug gauge, degree Trade
Nominal Nominal Wt. per Weight Weight Weight Weight
gauge and mitutoyo vernier, Size
Outside
Nominal Wall
Length 100 ft. (30.5M) w/
Pcs per Feet per
per per per per
Thickness Bundle Bundle
along with outside micrometer Diameter Couplings Bundle Bundle Bundle Bundle
and torque test machine are U.S. in mm In mm ft. Mtrs lb. kg. Pcs ft lbs Kg U.S. tons m tons
dedicate machines employed to 1/2 0.706 17.93 0.042 1.07 10 3.048 30 13.16 175 1750 525 238.15 0.263 0.238
3/4 0.922 23.42 0.049 1.24 10 3.048 46 20.9 125 1250 575 260.83 0.288 0.261
test the finished products for 1 1.163 29.54 0.057 1.45 10 3.048 67 30.4 150 1500 1005 455.85 0.503 0.456
100% quality assurance. 1 1/4 1.51 38.35 0.065 1.65 10 3.048 101 45.8 100 1000 1010 458.15 0.505 0.458
1 1/2 1.74 44.2 0.065 1.65 10 3.048 116 52.6 75 750 870 394.65 0.435 0.395
Certifications: 2 2.197 55.8 0.065 1.65 10 3.048 148 67.1 60 600 888 402.8 0.444 0.403
2 1/2 2.875 73.03 0.072 1.83 10 3.048 215 98 61 610 1312 597.7 0.656 0.595
Below are the list of
3 3.5 88.9 0.072 1.83 10 3.048 263 119.3 51 510 1341 608.4 0.671 0.609
certifications of all our best 3 1/2 4 101.6 0.083 2.11 10 3.048 349 158.3 37 370 1291 585.7 0.646 0.586
quality products. UL listed IMC 4 4.5 114.3 0.083 2.11 10 3.048 393 178.3 30 300 1179 534 0.59 0.535