Sei sulla pagina 1di 1

P

See what you can connect to. A few examples. N 220V / 110V www.Arduinoclub.de

V1.00
DIN A2 Z Y X Solid
The current and voltage depends on the PUL+(+5V) PUL+(+5V) PUL+(+5V)
State Milling Motor
PUL-(PUL) PUL-(PUL) PUL-(PUL)
Ralais
motor drivers, motors and other devices
DIR+ (+5V) DIR+ (+5V) DIR+ (+5V)
DIR- (DIR) DIR- (DIR) DIR- (DIR)
ENA+ (+5V) ENA+ (+5V) ENA+ (+5V)
ENA- (ENA) ENA- (ENA) ENA- (ENA)

you want to use.


DC+ DC+ DC+
DC- DC- DC-
A+ A+ A+
A- A- A-
B+ B+ B+
B- B- B-
220V / 110V

Spindle If you do not


need the manual Inverter
spindle control,
connect light
blue (1) to
green (2).

N
P
Soft Hard
1 2 Working with 110 or 220 volts Reset Reset
is life-threatening !
Dashed cables Please have the work carried What the control card

220V / 110V
Power filter

on / off optional for out by a specialist.


manual Spindle can do depends on
control.
the software you are

12V 1A
X Y Z X Y Z 6V
using.
HY01D523B
STEP/PUL DIREKTION GND Inverter DCM/FOR ENA SpRel
Speed R2.x
220 0,33uF LED 3mm
220 220

P UPF DRV DCM SPL SPM SPH RST REV FORACM VO 10V

AC-CNC2018-N-GRBL
R14 36 220 R16 C1

12V
O1

VIN
www.arduinoclub.de
FA FC FB 24V DCMSPH 5V ACM AI VI RS- RS+

PROBE
4 5 9

6V
R S T P+ PR U V W
0,1uF
P In config.h, uncommend Line 360 before you install the software. This will make sure that the

10k Ω Nano 3 / 5V C2 N 220V / 110V "SpRel" and your HF spindle will work together.
L

ABORT
#define USE_SPINDLE_DIR_AS_ENABLE_PIN

R12 10k

R8
R15

0-10V
Note
O3 O2

6V
R11
Water Pump for HF-Spindle

502

220
10k

0-5V

ext.RST
Solid

JP1
R13 1k 100uF State
220 R7 220 R6 220 R5 220 R4 R3 220 220 R2 220 R1 C3 Ralais

Limit control
Z Y X GND

Limit control
Visualize the
SpRel Tip!
LIMIT X LIMIT Y LIMIT Z R* COOLAND C.START F.HOLD status of your For an 800W spindle 12 litres of cooling water are usually Sufficient. Take a
6V 6V 6V 6V 6V 6V limit switches.
bucket of distilled water and put an oldcopper plate in the bucket, so no
algae will form, in the transparent cooling hose.
Tip!
The long pin on
the LED is the
plus pole.(Anode)
Water cooling
Resume

220V / 110V
Ralais
State
Solid
HF-Spindle

Program
L
P
Pause N

Tip!
PNP Sensor NC or NO Mechanical Switch Mechanical Switch
SIG Look in our shop, the switches
- Normally Closed - Normally Open we sell you are very
are very accurate.
accurate.
6V
Sensor
GND
X1 X2 Tip!
Of course you can also use only one limit switch per axis.

Attention !!
Please consider that the
Nano, the control card or Go
the software could fail,
therefore the emergency
stop is mounted in front https://github.com/gnea/grbl/wiki
of all other devices and for more info
Z1 Z2 Tip!
Z1 Z2
Note
EMERGENCY STOP switches off the whole In config.h, uncommend Line 204 before you install the software. Of course you can also use only one limit switch per axis.

machine. #define INVERT_LIMIT_PIN_MASK ((1<<X_LIMIT_BIT)|(1<<Y_LIMIT_BIT)|(1<<Z_LIMIT_BIT))


L N

We assume no warranty for damages that may occur if you work according
AC-CNC2018-N-GRBL_R2.x to these instructions. You are responsible for connecting all components correctly ! Copyright (C) ArduinoClub 2019

Potrebbero piacerti anche