HANDRAIL FOR STAIRCASE-3

NOTES
1. ALL DIMENSION ARE IN MILLIMETERS AND ALL LEVELS ARE IN METERS
AND CO-ORDINATES ARE IN METERS UNLESS NOTED OTHERWISE.

2. CIVIL & STRUCTURAL DRAWINGS SHALL BE IN CONJUNCTION


WITH MECHANICAL,ELECTRICAL,PIPING AND OTHER DICSIPLINE DWGS.

3. ALL WORKS SHALL BE IN ACCORDANCE WITH BS STANDARDS


EXCEPT AS NOTED OTHERWISE ON THE DESIGN DRAWING OR
WITHIN SPECIFICATIONS.
A A 4. ALL DIMENSIONS AND CONDITIONS MUST BE VERIFIED IN THE FIELD.
CONDITIONS NOT COVERED BY THE DRAWING OR SPECIFICATIONS
2725 912
SHALL BE BROUGHT TO THE NOTICE OF THE DESIGN ENGINEER
2725 912
BEFORE PROCEEDING WITH THE CONSTRUCTION.
908 908 908
5. STRUCTURAL STEEL MEMBERS SHALL BE OF GRADE S355JR.
E056 908 908 908
E056 E057 6. ALL CONNECTIONS ARE 8MM WELD U.N.O.
E055 7. DRAWINGS SHALL NOT BE SCALED. ONLY WRITTEN DIMENSIONS
A B C E055 E055
ARE FOLLOWED.
A C
B
144

144

144
HR031
D CHS48.3*3.2
D HR031
E057 CHS48.3*3.2
D D
E055

OPENING
882
958

KEY PLAN

1225
900
86 1524 752
175
HR019
HR028 CHS48.3*3.2 200 1123 201
CHS48.3*3.2

40
HR014
CHS48.3*3.2 HR033

791
900

CHS48.3*3.2

1200
DET -145
DET -145

867
E040 AMENDMENTS
TYP E040

933
725

TYP REV. DATE DESCRIPTION


3496

A 07.03.2018 ISSUED FOR APPROVAL

HR027
CHS48.3*3.2
900

1200
725

CHS48.3*3.2
867
CHS48.3*3.2
CHS48.3*3.2

HR014
933
5120
ISSUE

HR019
HR018

1200

SUBCONTRACTORS
CONTRACTOR

TECHNOPARK
DCD
Q.S.
ST. ENG.

TRAKHEES
CLIENT

MUNICIPALITY

TENDER ISSUE
DIC
MEP
DATE
738

725

867
933
1200
HR026
CHS48.3*3.2

3071
903
365
4063

3967

165
175
PROJECT & CLIENT

PROPOSED IDS WORKSHOP

894

800
OILFIELDS SUPPLY CENTER LTD.
2552

2552

PLOT No. TP030501C, TCHNO PARK, DUBAI


HR030
CHS48.3*3.2

1965

1965

168
CLIENT REPRESENTATIVE

98

136

66
B & A ENGINEERING
E E
E057 E E CONSULTANTS
E055 P.O.Box: 53363, Office 2201, Gold & Diamond Park-2
908 908 908
Dubai, United Arab Emirates, Tel: +9714 3791883,
830

830
Fax: +9714 3791884, Web: www.badriassociates.com

2725 912
CONSULTANT

1 A B C
1
A B C

STAIR HANDRAIL PLAN AT EL.+3.183 (F.F.L) STAIR HANDRAIL PLAN AT EL.+4.816 (F.F.L) Tel:04 2951822, Fax: 04 2951844, P.O Box :90201, Dubai, U.A.E
SCALE 1:20 SCALE 1:20 Email :designhousedubai@gmail.com www. designhouseuae.com

CONTRACTOR
CONTECH
ENGINEERING
PB.NO. 5750, DUBAI, UAE.
TEL. 04-8802662 FAX. 04-8802622

DRAWING TITLE

STAIR-3 HR PLAN @ EL.+3.153, +4.786

JOB NO. DRG.No. REVISION NORTH

E055 A
J-1654 SCALE DATE
NOTE : 1:20 07.03.2018
ALL CONNECTION DESIGN AND FABRICATION DESIGNED BY SRK