Sei sulla pagina 1di 1

NOTES

REVISIONS GENERAL
All drawings are in mm unless otherwise speci ied
Drawing are not scalled.only igured dimensions to be
used.
0.150 0.150 0.150
0.150 2.400 2.400 1.200 1.650 0.150 3.000 0.150 The builder must check and verify all dimensions
before commencement of any work

0.150

0.150
CONSTRUCTION
All soil and slab ground and under foundation to be
poisoned for termite control.

STORE
1.250
All slab at ground level to be poured over 1000 gauge
YARD
0.150

2.000
polythene sheet on 50 mm thick murram blindingon
5150 mm th. hardcore.
MASTER CIVIL.

0.150

0.150
1.200

50X100 SOFTWOOD TRUSS MEMBERS All soil on cut ebankment to be stablized .

DINNING
BATH The slope not to exeed the natural angle of repose.

0.150
10 MM PVC CEILING ON 900X600 ,50X50 BATERING STRUCTURAL

3.000
0.150 3.000 0.150
BR 02
0.150

All black cotton soil to be removed from all buildings


and paved survaces
KITCHEN 50X75 SOFTWOOD PURLINS
GAUGE 28 TILE PR0FILED GALVANISED SHEETS All R.C. works to refer to structural engineer's details

0.150 0.900 0.900 0.150


0.150
Depth of foundation to be determined on site to S.E's
S-01 S-01 approval all walls less than 150 mm th.to be
3.750

reinforced with loop iron at every alternate course.


MASTER PASSAGE SH MECHANICAL

0.150
1.800
All plumbing and drainage to comply with relevant
BEDROOM

5.163
local authority
WC
0.150

SVP denotes soil vent pipe to be provided at the head


150X200 RINGBEAM REINFORCED WITH T10 BARS
of drainage system.
ENTRANCE
0.150

0.150
STEEL CASEMENT WINDOWS FITTED WITH drains that pass beneath buildings and driveways to
12MM.D. MS.GRILLE be encasedin 150 mm concrete sorround.
PORCH

SITTING 150MM CONCRETE BED ON 50MM BLINDING


The storm drain pipes to comply with BS 556
speci ication.
3.000

3.000
4.950

BR 03 All underground foul and waste drain pipes shall be


0.150 3.000 0.150 150 MM TH. HAND PACKED HARDCORE FILLING. UPVC to comply with BS 5255
All inspection chambers covers and framing shall be
0.150 0.900 0.150

0.150 0.900 0.150


150 MM TH. BRICK FDN WALLING
cast iron.
450 MM WIDE X 150 MM TH. Minimum slope in the drains pipe to be 1 in 100.
PRESSED MDF FLUSH DOORS 1:2:4 CONCRETE STRIP FDN. No chases will be allowed for pipes.sleeves will be
allowed with written approval the approval of
CEMENT,SAND AND LIME PLASTERED WALLS WITH structural engineer.
0.150

SILK PAINT FINNISH No cutting of concrete without express approval


0.150 of the architect or structural engineer.
0.150 1.799 1.800 0.150 4.200 0.150 3.000 0.150 All testing of pipes must be completed before
S-01 BUILDING SECTION 1:100 plastering.
All mechanical works must be coordinated with
0. FLOOR PLAN (1) 1:100 electrical and any con lict must be clari ied
before works begin.
P.V. denotes permanent ventilation.
ELECTRICAL
All conduits must be laid before plastering.

MODERN FIRM
STRUCTURES

PROJECT :
PROPOSED RESIDENTIAL HOUSE
PROJECT LOCATION
ITABUA-EMBU

S-01 S-01 CLIENT:


E-04 RIGHT SIDE ELEVATION 1:100 SEBASTIAN M. IRERI
E-01 FRONT ELEVATION 1:100
DRAWING STATUS:
WORKING DRAWING
DRAWING NAME:
FLOOR PLAN,ROOF PLAN,
SECTION DRAWING,
FRONT ELEVATION,
RIGHT HAND ELEVATION,
REAR ELEVATION,
LEFT HAND ELEVATION.
DRAWN BY:
` CHARLES KINYUA JAPHETH
PHONE:0713740002

DRAWING SCALE
2. ROOF PLAN 1:100
1:100

E-03 REAR ELEVATION 1:100 E-O2 LEFT SIDE ELEVATION 1:100 CHECKED BY:....................................
SIGNED................................................

GSPublisherVersion 0.0.100.100