Sei sulla pagina 1di 1

PROJECT NAME:

BOUNDARY WALL
N PROPOSED RETAINING
WALL FOR
1063
FOOT PATH 20697 LAND OF HENRY PERERA
FLY MOUTH PVT(LTD)
225
AT NO:108 SAMA MAWATHA,
21940
PROPOSED BOUNDARY WALL AKUREGODA,PELAWATTE,
75mm PVC(T-600)
WEEP HOLE
BATTARAMULLA
PROPOSED RETAINING WALL

2/1mx1m TYPICAL
GABION BOXES
LAND OF SILVA
NOTES:
LOT 12
1. DESIGN WAS BASED ON THE
OBSERVATIONS MADE DURING THE SITE
VISIT.
2. ALL REINFORCED CONCRETE BELOW EGL
LOT 14 TO BE Gr.25
FRONT ELEVATION SITE PLAN 3. ALL REINFORCED CONCRETE ABOVE EGL
SCALE 1:100 SCALE 1:500
PLAN No - CO/8/92 TO BE Gr.20
LOT - 11
FULL LENGTH OF RETAINING WALL -24.0m 4. REINFORCEMENT TO BE OF
CHARACTERISTIC STRENGTH 500N/mm²
5. SCREED CONCRETE/MASS CONCRETE TO
BE Gr.15 CONCRETE
3000

3000
NEW BOUNDARY WALL NEW BOUNDARY WALL

HAND RAIL

EXISTING RETAINING WALL


75mm THK SCREED 2:1
1697

1697
CONCRETE(GRADE 15) T10-13-250
T10-11-250
07 07
200
1900
T10-12-250
NON WOVEN

350
4T12
GEOTEXTILE 4T12
LAYER FOR WEEPHOLE LOCATION FOOT PATH R6@200 C/C

2850
R6@200 C/C
250
200mm THK RCC WALL 200mm THK RCC WALL

200
200
FILTER PACK RUBBLE (150x225) FILTER PACK RUBBLE (150x225)

75mm PVC(T-600) WEEP HOLE 75mm PVC(T-600) WEEP HOLE .......................................................................


PIPE AT 1500mm C/C STAGGERED PIPE AT 1500mm C/C STAGGERED
100mm THK APPLICANT'S SIGNATURE
HOLLOW BLOCK WALL
5725

5725
COMPACTION COMPACTION
T10@250 C/C
TO BE 95% OF MODIFIED PROCTOR TO BE 95% OF MODIFIED PROCTOR
COMPACTION COMPACTION
TEST(WELL RAMMED) TEST(WELL RAMMED) 4T10 & R6@250C/C
1000 1000
450 225
900 900 T10-08-200
150

2/1mx1m 2/1mx1m .......................................................................

250
TYPICAL GABION BOXES TYPICAL GABION BOXES
T10-07-200
LAND OWNER'S SIGNATURE
1700

1700

150
NON WOVEN NON WOVEN
GEOTEXTILE LAYER GEOTEXTILE LAYER
2100

2250

600
5T10
1000

1000
100mm THK CONCRETE

50
300

300

300 .......................................................................
1700 1250 1:3:6 MASS CONCRETE 1700 1250 1:3:6 MASS CONCRETE 350
CHARTED ENGINEER'S SIGNATURE

SECTION X-X ( ALONG A - B) SECTION Y-Y ( ALONG B - C) DETAIL OF BOUNDARY WALL


05 05
SCALE 1:50 SCALE 1:50 SCALE 1:20

600
EXISTING RANDOM RUBBLE
X MASONRY WALL STIFFENER COLUMN @ EVERY
-
4500mm INTERVALS DESIGNED BY: WA
Y T10-09-200
- 07 07
1063

13855 DRAWN BY: CA


1217

6844 T10-10-200
200
200

2600 A 11009 B
828

3600
DATE: 14.08.2019
3739
T12-06-200
1900

DRAWING TITLE
T12-05-200
8200
200

RETAINING WALL DETAIL


COUNCIL DRAWING
990

X
-

C T12-03-200 T12-04-200

PROPOSED GABION WALL


Y
300 300
SCALE : AS SHOWN
-
PROPOSED CONCRETE
T12-01-200 T12-02-200
RETAINING WALL
LINE OF CONCRETE FOOT PATH ABOVE SOIL FILL A1 A2 A3 A4
PLAN OF RETAINING WALL REINFORCEMENT DETAIL OF RETAINING WALL
SCALE 1:50 SCALE 1:20