University of Engineering and Technology, Lahore

SYNCHRONIZATION AND ATS AT SMART GRID

5.SYNCHRONIZATION MODULE
1.ABSTRACT 2.OBJECTIVE GC600 mains is the perfect solution
ATS Synchronization approach is implemented in To obtain a reliable power system in for the management of a genset working in
this project. An Automatic Transfer Switch( ATS) is which seamless transition between parallel to the mains by the internal power
an electrical switch that switches a load between two sources is obtained to ensure regulator. Soft loading and un-loading is
two sources. It is often installed with a backup gen- continuous electrical supply to avoid automatically performed.
erator, so as to provide temporary blackouts. GC600 mains is a power-
electrical power in case of mains electrical ful genset controlled de-
power failure. Synchronization module signed for synchro/parallel
will be used for this purpose. applications. Based on the
load demand controller is
3.METHODOLOGY able to start or stop the
genset.
ATS Synchronization function involved in this project includes following steps:
 A short while before normal power source fails; the genset is synchronized with the main
6.SPECIFICATIONS OF ATS
power supply.
SYNCHRONIZATION
 When the main power source fails, the transfer switch breaks its connection to the mains
and shifts the electrical load to the emergency power source.  ATS Synchronization system are automatic to
avoid any accident due to manual operation.
 When utility power is restored, the transfer switch returns load from the generator to
the normal one.  All ATS Synchronization sys-
tem include load sharing
function to ensure balanced
use of the different gensets.
4.CONDITIONS FOR ATS SYNCHRONIZATION
 Load sharing function is
In order to synchronize a generator to the grid, four conditions must be met:
available as option when en-
 Phase Sequence ergy demand is low, only
 Voltage Magnitude one genset starts the other
 Frequency remains in standby unless
 Phase Angle the demand increases
Synchronization is achieved when the above
mentioned parameters are identical for the
two sources.
SUMMARY
According to load demand the utility
grid and genset are synchronized
SUPERVISED BY through module and hence un-
GROUP MEMBERS interrupted supply is available to the
Dr.Sohail Aftab Qureshi
2014-EE-157 Hira Mahmood load.
2014-EE-160 Sana Amer
2014-EE-161 Sumbal Mehmood
REFERENCES
2014-EE-185 Ahmad Khan http://www.sices.eu/en/products/electronic-control-devices/synchro- parallel-genset-
controllers

Potrebbero piacerti anche