Sei sulla pagina 1di 8

Internal Use Only

http://biz.lgservice.com

Room Air Conditioner


SVC MANUAL(Exploded View)
MODEL : US-W091BSA0
US-W121BSA0

CAUTION
Before Servicing the unit, read the safety precautions in General SVC manual.
Only for authorized service personnel.
1. Specification
Sales Model US-W091BSA0 US-W121BSA0
Models Unit LSN090HXV/LSU090HXV LSN120HXV/LSU120HXV
kW 2.49 3.52
Cooling Capacity
Btu/h. 8,500 12,000
kW 3.19 3.81
Heating Capacity
Btu/h. 10,900 13,000
Power Input Cooling/Heating W 708/880 1,143/1,088
Running Current Cooling/Heating A 6.15/7.65 9.94/9.46
Starting Current Cooling/Heating A 6.15/7.65 9.94/9.46
Cooling COP 3.73 3.08
EER 12.01 10.5
SEER - 17.0 17.0
HSPF 9.0 9.0
Power Supply Ø / V / Hz 1/115/60 1/115/60
Power Factor % 98 95
Indoor (Max/H/M/L) m3/min(CFM) 9.5(335)/7.7(272)/6.0(212)/3.5(124) 9.5(335)/7.7(272)/6.0(212)/3.5(124)
Air Flow Rate
Outdoor,Max m /min(CFM)
3
28(1,000) 28(1,000)
Moisture Removal l/h(pts/h) 1.1(2.3) 1.3(2.8)
Indoor, H/M/L dB(A)±3 39 / 33 / 25 39 / 33 / 25
Sound Level
Outdoor,Max dB(A)±3 47 47
Refrigerant & Charge (at 7.5 m/24.6ft) g(oz) R410A, 900(31.7) R410A, 900(31.7)
Additional Refrigerant charge g/m(oz/ft) 20(0.22) 20(0.22)
Type Single Rotary Single Rotary
Model GA102MDB GA102MDB
Motor Type Brushless DC Motor Brushless DC Motor
Compressor
Oil Type PVE(FVC68D) PVE(FVC68D)
Oil Charge cc 310±5 310±5
O.L.P. name - -
Type Cross Flow Fan Cross Flow Fan
Fan(Indoor)
Motor Output W 20 20
Type Propeller Propeller
Fan(Outdoor) Motor Type BLDC BLDC
Motor Output W 43 43
Circuit Breaker* A 20 20
Power Supply Cable No.*mm2 (AWG) 3*2.0(14) 3*2.0(14)
Power and Transmission Cable No.*mm2 (AWG) 4*1.0 (18) 4*1.0 (18)
Liquid Side mm(in) 6.35(1/4) 6.35(1/4)
Piping Connections
Gas Side mm(in) 9.52(3/8) 9.52(3/8)
Drain Hose(O.D / I.D.) mm(in) 21.5 / 16.0(27/32 / 5/8) 21.5 / 16.0(27/32 / 5/8)
mm 885*285*210 885*285*210
Indoor (W*H*D)
inch 34 13/16* 11 7/32* 8 1/4 34 13/16* 11 7/32* 8 1/4
Dimensions
mm 717*483*230 717*483*230
Outdoor (W*H*D)
inch 28 7/32* 19 1/32* 9 1/32 28 7/32* 19 1/32* 9 1/32
Indoor kg(lbs) 10.2(22.5) 10.2(22.5)
Net Weight
Outdoor kg(lbs) 28(61.7) 28(61.7)
Indoor kg(lbs) 12.4(27.3) 12.4(27.3)
Gross Weight
Outdoor kg(lbs) 30(66.1) 30(66.1)
Cooling(Outdoor) °C(℉)DB -10 ~ 48{14 ~ 118.4} -10 ~ 48{14 ~ 118.4}
Operation Range
Heating(Outdoor) °C(℉)WB -10 ~ 24 (14 ~ 75.2) -10 ~ 24 (14 ~ 75.2)
Piping Length (Min/Max) m(ft) 2(6.6) / 15(49.2) 2(6.6) / 15(49.2)
Chargeless m(ft) 7.5(24.6) 7.5(24.6)
Max. Elevation Difference m(ft) 7(23.0) 7(23.0)
Tool Code(Chassis) Indoor + Outdoor SB + UA3 SB + UA3
Temperature Control O O
Allergy free filter - -
Plasma Filter - -
Prefilter(washable/anti-fungus) O O
3M Multi Protection filter X X
Auto Clean O O
CHAOS Wind(Auto Wind) O O
Steps, Fan/Cool/Heat 6/6/6 6/6/6
Airflow Direction Control(Up& Down) Auto Auto
Airflow Direction Control(Left & Right) Auto Auto
Remote Controller Type Wireless LCD Wireless LCD
Setting Temperature Cooling 18℃~30℃(64.4℉~86℉) 18℃~30℃(64.4℉~86℉)
Range Heating 16°C ~ 30°C(60.8℉~86℉) 16°C ~ 30°C(60.8℉~86℉)
Functions
Auto Operation (Micom Control) - -
Auto Changeover (Micom Control) O O
Self Diagnosis O O
Timer 24h, On/off 24h, On/off
Sleep Operation O O
Soft Dry Operation O O
Restart Delay(minute) 3 3
Deice Control(Defrost) O O
Hot Start O O
Jet Cool O O
Jet Heat O O
Low Ambient Operation O O
Special Function Water Level Sensor Water Level Sensor

Note:
Conversion Formula
1. Capacities are based on the following conditions:
Cooling: - Indoor Temperature 27°C(80.6°F) DB/19°C(66.2°F) WB kW = Btu/h x 0.0002931
- Outdoor Temperature 35°C(95°F) DB/24°C(75.2°F) WB
Heating: - Indoor Temperature 20°C(68°F) DB/15°C(59°F) WB
cfm = CMM x 35.3
- Outdoor Temperature 7°C(44.6°F) DB/6°C(42.8°F) WB
Piping Length - Interconnecting Piping Length 7.5m
- Level Difference of Zero
2. Wiring cable size must comply with the applicable local and national code.
3. The specification may be subject to change without prior notice for purpose of improvement.

Copyright ©2014 LG Electronics. Inc. All right reserved. -2-


LGE Internal Use Only
Only for training and service purposes
2. Piping Diagrams

Indoor Unit Outdoor Unit

Liquid Side

2-Way Valve EEV

Th1

Th2
Heat Heat
Exchanger Exchanger
Th5
(Evaporator) (Condenser)

Th4

Gas Side

Reversing Valve
3-Way Valve Accumulator

Th3

Compressor Cooling
Heating

LOC. Description PCB Connector


Th1 Thermistor for air temperature CN-TH1(Indoor)
Th2 Thermistor for evaporator middle temperature CN-TH2(Indoor)
Th3 Thermistor for discharge pipe temperature CN-TH2(OUTDOOR)
Th4 Thermistor for condensing temperature CN-TH1(OUTDOOR)
Th5 Thermistor for outdoor air temperature CN-TH1(OUTDOOR)

❈ EEV : Electronic Expansion Valve

Copyright ©2014 LG Electronics. Inc. All right reserved. -3-


LGE Internal Use Only
Only for training and service purposes
3. Wiring Diagrams
Indoor Unit

MEZ65064707

N-U/D
CN-
N-L/R
CN- N-DISP3
CN-

CN-
N-MOTOR
N-DISP1
CN-

CN-
N-TH1
N-TH2
CN-
N-TH3
CN-
CN-
N-CN-
N-REMO

CN-CC CN-LINK

Copyright ©2014 LG Electronics. Inc. All right reserved. -4-


LGE Internal Use Only
Only for training and service purposes
Outdoor Unit

CN-U(R)
CN-V(S) CN-EEV
CN-W(C) CN-TH1
CN-FAN(DC)
CN-4Way
CN-TH2

CN-COM

CN-COIL1
WCN-P(L)

CN-3

CN-COIL2 CN-E WCN-P(N)

Copyright ©2014 LG Electronics. Inc. All right reserved. -5-


LGE Internal Use Only
Only for training and service purposes
4. Exploded View
Indoor Unit
Model : USNW091BSA0/USNW121BSA0

135316

135500B

152302A

131410

135313

149303 733010

149304
267110 342800
135500A
354210

135080
354212

359011 346810
352150 263230A
146811B

268711C

135500C
147582
W6640A
35211B
146811A
W50400
263230B
145200
249951
147581
135311

LOC. Description
263230A Thermistor for air temperature
263230B Thermistor for evaporator middle temperature

Note) * Please ensure GCSC since the replacement parts may be changed depending upon the buyer’s request.
Please check the correct parts in View RPL(Replacement Part List) on GCSC.
(GCSC Website http://www.lge.com)

Copyright ©2014 LG Electronics. Inc. All right reserved. -6-


LGE Internal Use Only
Only for training and service purposes
554031
Outdoor Unit

137213A
661400
552200

Only for training and service purposes


552112 137213B
435511B

559010 546810

Copyright ©2014 LG Electronics. Inc. All right reserved.


437211 55211G
Model : USUW091BSA0/USUW121BSA0

552203A

549610

- 7-
435301 261704 552203B
W4986B 148000
649950 552202

135500C

554160
W4986A

447910

237202

W4986C W6631
550140
561410

430410
552116

LGE Internal Use Only


P/NO : MFL67499959 March, 2014