Sei sulla pagina 1di 4

AUTOTEC ÑÐÛÎßÌ×ÑÒ ÓßÒËßÔ

JUMBO INDICATOR

AUTOTEC

Technical Specification
1) Display : 4 digit, 7 segment LED display, Size- 4”
2) Size : 160 X 380 X 50 (H x W x D)
3) Input : 0-10V DC, 0-20 mA DC, 4-20 mA DC ( selectable )
4) Scalable range : -999 to 9999 (selectable)
5) Range & Decimal Point selectable. Reverse scaling possible.
6) Power Supply 100V-250V AC (SMPS)

Configuration
1) Menu setting procedure,
(a) Parameter menu : press SET + key together.
(b) Factory Setting : press SET + key together.
2) Press SET key to confirm the change and to go to next step.
3) Press ENTER key to SAVE & EXIT.
4) Auto-exit is for 30 sec. Menu exit without saving.
5) In PARAMETER MENU, signal low level mode is for 4-20mA DC input only
(ampere range : 0-5mA DC)
6) In PARAMETER MENU, range will be (-999 to 9999), reverse scaling possible
selected out of three.

Page - 1
USER CONFIGURATION

Process Value
Press SET + key for 10 sec

Parameter message
Press SET key

Input
Press SET key

0-10V DC Select by key


4-20mA DC 0-20mA DC
Decimal Point
Press SET key

Press key to set the Position of DP


Press SET key

Low Range
Press SET key

Press & key to set value


Press SET key

High Range
Press SET key

Press & key to set value


Press SET key

Filter time (range: 1 sec to 10 sec)


Press SET key

Press & key to set value


Press SET key

Off-set (range: -+ 100 counts)


Press SET key

Press & key to set value


Press SET key

Correction Factor (range: -+ 999 counts)


Press SET key

Press SET key


Signal Low Level (ampere range : 0-5mA)
only for 4-20mA
Press SET key
Press SET key
Press & key to set value between 0.0 to 5.0
Press ENTER key for
save & exit

Page - 2
FACTORY SETTING

Process Value
Press SET + key for 10 sec

Factory setting
Press SET key

0-10V DC Select by key


4-20mA DC 0-20mA DC
Press ENT key for SAVE & EXIT

EXIT

FACTORY PARAMETER SETTING

Parameter 0-10V DC 0-20V DC 4-20V DC


Low Range 0 0 0
High Range 1000 2000 2000
Decimal Point 0000 0000 0000
Filter Time 1 sec 1 sec 1 sec
Off-set 0 0 0
Correction factor 0 0 0
Signal Low Level 0 0 3.5 mA

Page - 3
Terminal Connection Diagram

0 - 10V DC

0/4 -20mA
DC

Supply
100V-250V AC
(SMPS)

Bottom

For Further Enquires Please contact us :-


AUTOTEC
B-120,Udai Vihar, Road No. 12, Near Airtel, Thokar Madri Road, Madri, Udaipur – 313001 Rajasthan , India
Telefax: Mobile: +91-9829041252,+91- 9214905083
Email : autotec@autotecindia.com, Website: www.autotecindia.com

Page - 4