Sei sulla pagina 1di 2

8/15/2019 Check List API Rp 14c | Pump | Boiler

 Search    

RELATED TITLES
views 1 0
559Download 1 of 72  Search document 
Check List API Rp 14c
Uploaded by MIGUELONOFRE on Oct 16, 2013 
Full description

   
Save Embed Share Print Safety Critical Safety Design and 7000 PROCESS
Elements /… API RP 14C SAFETY SYSTEM T2

Download 1 of 72  Search document 


 

API RP 14C CHECKLIST


TABLE OF CONTENTS

A.1 Wellhead and Flow Lines

A.2 Wellhead Injection Lines

A.3 Headers

A.4 Pressure Vessels

A.5 Atmospheric Vessels

A.6 Fired and Exhaust Heated Components

A.7 Pumps

A.8 Compressors
A.9 Pipelines

A.10 Heat Exchangers

A.11 Miscellaneous Items Not Specifically Addressed in 14C


https://www.scribd.com/document/176712957/Check-List-API-Rp-14c 1/52
8/15/2019 Check List API Rp 14c | Pump | Boiler
p y

Related
 titles Search    

Download Emergency Shutdown 1Systems


of 72 (ESD)  Search document 
Fire Detection Systems

Combustible Gas Detection Systems

Sumps

Pneumatic Supply Systems

Safety Critical Safety Design


Systems and 7000 PROCESS
for Discharging API - RP 14C (Vents
Gas to Atmosphere Comparison
and Flares) SAFETY INTEGRIT
Elements /… API RP 14C SAFETY SYSTEM T2 Analysis, Design… Between ASME… LEVEL

Process Piping and Instrumentation


Diagrams, EWZ-001-02-P04-W021  Attachment C – Revision 0 Page 1 o

API RP 14C C

WELLHEADS AND FLOW LINES


Wellheads furnish surface control (manual and automatic) and containment of well fluids and provide downhole access for well servicing. Flow lines transport hydro
from the wellhead to the first downstream process component.

For analysis purposes and assignment of safety devices, flow line are divided into flow line segments. A flow line segment is any portion of a flow line that has an as
operating pressure different from other portions of the same flow line. These flow line segments can be classified s either initial (beginning at wellhead), intermediat
(terminating at another process component) segments. Thus, a flow line that experiences a reduction in operating pressure due to some inline pressure reducing devic
choke, and has two different assigned operating pressures, will have an initial and final segment. A flow line that experiences no reduction in operating pressure due
 pressure reducing device will have only one segment. In this case, the initial and final flow line segment will be the same. Each flow line segment must be analyzed t
appropriate safety devices. Recommended safety devices for typical wellheads and flow lines are shown in Figures A.1.1, A.1.2 and A. 1.3.

14C ITEM SAC REFERENCE NOTES

A.1 Wellhead and Flow Lines


a. High Pressure Sensor (PSH)
1. PSH installed.
2. Flow line segment has a maximum
allowable working pressure greater than
maximum shut in pressure and is
protected by a PSH on downstream flow
line segment.
b. Low Pressure Sensor (PSL)
1. PSL installed.
2. Flow line segment is between the well
and the first choking device and is less
than 10 feet (3m) in length or, in the case
of an underwater installation, reasonably
close to that distance.

https://www.scribd.com/document/176712957/Check-List-API-Rp-14c 2/52