Sei sulla pagina 1di 12

BOLT TIGHTENING REPORT

Quantity of
Flange Bolt Properties

Gasket
Type
Joint Size

Nut
No Lline No : Nut Size Length
No : Size Rating Meterial New Reuse
( mm ) ( mm )
( Inch )
Comments ( Any concenssions need to be recorded here ) :
COMPLETED BY SUBCONTRACTOR

Sign & Stamp

Name

Date
Project Code

PORT Report No
Type Of Blind B.Limit / EIS
Test Pack No/Equip No

Acceptable
Defect Blinding / Remove De-Blinding / Install
Tightening

Lubricant
Torque Value ( Ft-Lbs )

Aligned

Applied
Method

Flange

Flange
RFI No :

Face
Yes No Joint Joint
30% 60% 100% Date Sign Date Sign
Maker Maker
Gasket Legend Methold of Tightening Misalignment

CNAF MTW
PIPE SIZE TOLERANCE
Compressed Non-Asbestos Fibre Menual Torque Wrench
SW HTW
Up To 4" 1.0mm
Spiral Wound Hydraulic Torque Wrench
RTJ HBT
6" To 10" 2.0mm
Ring Type Joint Hydraulic Bolt Tensioning

12" To 24" 3.0mm


12" To 24" 3.0mm
Lubricant
Molykote 1000

CONTRACTOR COMPANY
QC/A/F86 Rev 0

Client
Site
Piping / Mechanical

Gap Point
( Gap mm / Offset mm )

A B C D
* Gap must be uniform . Perform gap adjustment by
selective tightening if requieds

COMPANY
JIT
ACCEPTOR
Contractor :

COMPANY :

Date :
JIT ID
NAME NAME
IC/PASSPORT IC/PASSPORT
TRAINING DATE TRAINING DATE
JIT ID NO. JIT ID NO.

STAMP & SIGN CONTRACTOR STAMP & SIGN COMPANY


JOINT MAKER TEAM
NAME STAMP & SIGN
IC/PASSPORT CONTRACTOR
TRAINING DATE
STAMP & SIGN
JIT ID NO. COMPANY

Potrebbero piacerti anche