Documenti di Didattica
Documenti di Professioni
Documenti di Cultura
Longitud de la viga : L = 30
Ancho total de la calzada : w total = 9.00
Número de vigas : N = 4
1.1.- Superestructura
Tipo de cable : Cable estabilizado de 12 torones (12 V ½") grado 270 ksi
1.2.- Subestructura
P=1 P=1
0.60 1.80 m S + a – 2.40
E I
a S
9.00 = 2a + 3s
fi = 0.600 s
s = 2.44 m
a = 0.84 m
w = 9.00 m a 0.6
b 1
fe = 1.46 c -6
fi = 1.46
Adopto: Ø 10 mm c/ 7.50 cm
% Asrep1 = 83.36 % Para el area de acero corrugado de distribucion
% Asrep = 67.00 % Elegido el menor de 67% y el valor de %Asrep1
Adopto: Ø 10 mm c/ 10.00 cm
Adopto: Ø 10 mm c/ 20.00 cm
0.65
m
0.25
m
0.2 m 0.2 m
0.60 0.50 1.50 0.50 1.50
m m m m m
0.20
m 0.79 S= S=
m 2.69 2.50
m m
0.08 0.12
m m
0.02
0.12
0.32
m
0.90
m
0.12
m
0.10 0.32 C b = 1.00
m m
0.10 0.32 C b = 1.00
m Sobre Carga q = 290 m
Kg/cm2
A
0.15
m 0.30 x = 0.60 m
B Bm Carpeta de
C rodadura
0.05 0.15
m
0.20
m
q
0.69
0.45 0.20 m
m m
bo = 0.65 a = 0.79 m
m
1.44
m
A
0.20
m
Fuerz FiM
γ [Kg/m3] b [m] h [m]
a [Kg/m]
F1M - - - 100.00
F2M 2500 0.45 0.15 168.75
F3M 2500 0.20 0.42 210.00
F4M 2500 0.84 0.17 358.97
F5M 2200 0.84 0.01 14.13
E = 1.58 m
F6V = 4607.427427 Kg/m
F4V = 0.00 Kg
Fuerza MCM
FiM Brazo [m]
[Kg/m] Kg·m/m
F1M 100.00 1.44 144.46
F2M 168.75 1.27 214.25
F3M 210.00 0.94 198.38
F4M 358.97 0.42 151.60
F5M 14.13 0.42 5.97
853.10 679.90
MCV [Kg·m/m]
FiV Fuerza
Brazo [m]
[Kg/m]
1er caso 2do caso
Cuando las losas de H°A son vaciadas sobre vigas prefabricadas de H°A y perfiles metalicos,
los momentos de la losa exterior con relacion al eje dela viga de apoyo; sin embargo estos
momentos son reducidos según muestra la figura.
Mu = 6079.17 Kg·m/m
Ø = 10.00 mm
d = 14.00 cm
a = 2.49 cm
As = 10.59 cm2/m
Adopto: Ø 10 mm c/ 7.00 cm
% Asrep1 = 83.36 %
% Asrep = 67.00 %
Adopto: Ø 10 mm c/ 11.00 cm
5.- DISEÑO DEL BORDILLO
Mu = 684.13 Kg·m/m
5.2.- Cálculo de Armadura
Ø = 10.00 mm
d = 22.00 cm
a = 0.16 cm
As = 0.69 cm2/m 5
Adopto: Ø 10 mm c/ 15.00 cm
Adopto: Ø 10 mm c/ 15.00 cm
Fuerza MCM
FiM Brazo [m]
[Kg/m] Kg·m/m
F1M 100.00 0.40 40.00
F2M 168.75 0.23 37.97
77.97
Fuerza MCV
FiV Brazo [m]
[Kg/m] Kg·m/m
F1V 0.00 0.36 0.00
F2V 0.00 0.96 0.00
F3V 0.00 0.52 0.00
F4V 0.00 0.23 0.00
0.00
MCV+I = 0.00 Kg·m/m
Mu = 101.36
Ø = 10.00 mm
d = 12.00 cm
a = 0.04 cm
As = 0.19 cm2/m
Adopto: Ø 10 mm c/ 20.00 cm
Adopto: Ø 10 mm c/ 15.00 cm
7.- DISEÑO DE LA VIGA POSTESADA
h = 1.50 m
w = 0.11 m3
b1 = 0.66 m
b = 0.50 m
Losa de Hormigón
Viga Postesada
15 cm
27 cm
25 cm
25 cm
7.2.- Características de la Sección Tipo IV
B1 = 50.00 cm
B2 = 66.00 cm b1 t b1
t = 20.00 cm
b1 = 15.00 cm 2
h1
b2 = 23.00 cm
H = 155.00 cm 3 3
h2
h1 = 25.00 cm
h2 = 20.00 cm
h3 = 58.00 cm H 1
h3
h4 = 27.00 cm
h5 = 25.00 cm
4 4 h4
O.K. !!!
### 5
h5
b2 t b2
B2
I1 = 2021718.68 cm4
I2 = 6478895.17 cm4
I3 = 416212.86 cm4
I4 = 434639.88 cm4
I5 = 5707344.88 cm4
I = 15909664.20 cm4
ws = 1891053.37 cm3
wi = 224494.71 cm3
b1 = 7.5 m
b2 = 2.44 m
b3 = 2.54 m
b = 2.44 m
η = 0.85
bo = 2.06 m
AT = 9422.25 cm2
a = 66.71 cm
a' = 49.71 cm
b = 105.29 cm
bo =2.05 m
t = 0.16 m
.1 m
Ysc=57.17 cm
Y’sc=41.17cm
Y’sc=41.17cm
h = 1.35 m
Yic=93.83 cm
0.66 m
I1 = 3551167.50 cm4
I2 = 1795837.57 cm4
I3 = 52167.81 cm4
I4 = 1590616.69 cm4
I5 = 14292400.48 cm4
I6 = 11947985.73 cm4
Ic = 34872960.27 cm4
ws = 522754.34 cm3
ws' = 701527.57 cm3
wi = 331208.78 cm3
q = 1000 Kg/m
13500.0kg
7250kg
+
7250 kg -
13500 kg
64843.75kgm Mmax=91124.75kgm 64843.75kgm
+ +
7.5.1.- Esfuerzo por peso propio del bordillo + acera + barandado + C.r.
Elemento qb [Kg/m]
Protectores 240.00
Aceras
Bordillo
Capa de rodadura 200.48
440.48
Momentos
X = 14.3 m
x 1.433 14.28 4.30 0.72 3.58
η1 = 5.44
η2 = 7.07
η3 = 5.14 14.285
15.715
M = 13.57 P 107100
Mp = 98503.83 Kg·m 61237.5
168337.5
M max = 144026.6 Kg·m 126253.125
I1 = 0.22
I = 0.22
ΔM = 341718.94 Kg·m
η = 20.00 %
ks = 37.91 cm
ki = 31.94 cm
rmin = 3.95 cm
Øvaina = 6.67 cm 0.033338
d' = 0.15 m
d' = 0.13 m
e = 57.87 cm
10.45
13.7 3.25
Si fti = 15.0 Kg/cm 2
y fts = 29.93 Kg/cm2
emin = 57.87 cm
emáx = 397.53 cm
Perdidas= 20.00 %
Pi = 557520.58 Kg
Pototal = 567868.66 Kg
fo = 8569.809328 psi
fm = 13288.0 Kg/cm2
ΔLprevisto = 214.01 mm
ξ = 0.01 0.21
ΔLprevisto = 214.01 mm
σs = -85.17 Kg/cm2
σi = -169.86 Kg/cm2
σc = -162.76 Kg/cm2
K = 0.003 /m
μ = 0.200 /rad
CABLE Po [Kg] e [cm] Ø [rad] K·L+μ·Ø Px [Kg]
1 180275.76 51.20 0.07 0.06 170006.05
2 180275.76 57.87 0.08 0.06 169704.05
3 180275.76 64.54 0.09 0.06 169402.58
ΔPprom = 10571.54 Kg
d) Determinación optima de Pi
fi = 14553.0 Kg/cm2
Pi = 518272.59 Kg
Ri = 0.91
η = 8.73 %
PERDIDAS INSTANTANEAS Δf [Kg/cm2] %
Deslizamiento de anclajes 0.00 0.00
Acortamiento elastico del hormigón 502.11 3.15
Fricción 890.54 5.58
1392.65 8.73
Pimax H° = 651602.99 Kg
Pimax A° = 540827.29 Kg
t = 28 días
ξh = 0.000356
fcorreción = 0.60 %
ξh corregido = 0.000213
Pir = 466445.34 Kg
Mtotal = 268550.51 Kg·m
σs = -78.71 Kg/cm2
σi = -79.39 Kg/cm2
σc = -79.33 Kg/cm2
Cu = 2.65
Δffl.plas. H° = 1297.15 Kg/cm2
Δffl.plas. A° = 860.72
d) Determinación optima de Pe
fe = 11989.77 Kg/cm2
Pe = 426989.66 Kg
R = 0.82
η = 17.61 %
Pemin H° = 370042.25 Kg
Pemax A° = 473223.88 Kg
Viga
Losa
ρp = 0.0
t = 8.46 cm
a = 7.95 cm
c = 9.36 cm
7.11.2.- Verifiración
Q [Kg] M [Kg·m]
ELEMENTO sec 1 sec 2 sec 3 sec 4 sec 1
x=0.00m x=0.63m x=1.13m x=6.25m x=0.00m
Viga 17132.8 16095.70 15266.02 8320.31 0.00
Losa + diafragm 8953.24 8531.36 8193.86 4734.49 0.00
Acera + baranda 4533.49 4306.81 4125.47 2266.74 0.00
Total 30619.5 28933.87 27585.35 15321.54 0.00
7.12.2.- Cortante por carga viva
X = 0.00 m
η1 = 1.00 η1 =
η2 = 0.86 η2 =
η3 = 0.71 η3 =
Q = 2.04 P M =
Qp = 14774 Kg Mp =
I1 = 0.22 I1 =
I = 0.22 I =
X = 0.68 m
η1 = 0.98 η1 =
η2 = 0.83 η2 =
η3 = 0.69 η3 =
Q = 1.98 P M =
Qp = 14407 Kg Mp =
I1 = 0.22 I1 =
I = 0.22 I =
X = 1.15 m
η1 = 0.96 η1 =
η2 = 0.82 η2 =
η3 = 0.68 η3 =
Q = 1.95 P M =
Qp = 14148 Kg Mp =
X = 6.75 m
η1 = 0.78 η1 =
η2 = 0.63 η2 =
η3 = 0.49 η3 =
Q = 1.53 P M =
Qp = 11099 Kg Mp =
I1 = 0.22 I1 =
I = 0.22 I =
sección Qu [Kg]
1 97098.95
2 93482.28
3 90726.22
4 62958.55
Sección 2
d = 124.00 cm
fd = 4.63 Kg/cm2
e = 5.01 cm
fpe = 81.64 Kg/cm2
Mcr = 24008853.1540911 Kg·cm
Vi = 38623.5 Kg
Mmax = 2563163.95 Kg·cm
Vci = 394580.37 Kg
ø = 4.24 °
Vp = 31588 Kg
Vcw = 212684.77 Kg
Vc = 212684.77 Kg
Vs = -102706 Kg
s = 20 cm
Adopto: 1 EØ 10 c/ 20 cm
Sección 3
d = 124.00 cm
fd = 8.11 Kg/cm2
e = 8.39 cm
fpe = 88.08 Kg/cm2
Mcr = 24671241.6139983 Kg·cm
Vi = 37642 Kg
Mmax = 4363130.37 Kg·cm
Vci = 244813.42 Kg
ø = 4.17 °
Vp = 31079 Kg
Vcw = 212175.85 Kg
Vc = 212175.85 Kg
Vs = -105439.1 Kg
s = 20 cm
Adopto: 1 EØ 10 c/ 20 cm
C = 576563.5581
T = 576563.5581
7.14.1.-Caracteristicas de la sección
AT = 6637.50 cm2
I = 9846469.72 cm4
ws = 152315.27 cm3
wi = 163143.44 cm3
x = 38.75 cm
e = 2.90 cm
σs = -68.21 Kg/cm2
σi = -87.30 Kg/cm2
7.14.2.-Momentos de la fuerza pretensora
y [cm] M [Kg·cm]
155.00 -49754169.1
142.50 -43275761.7
130.00 -36797354.2
117.50 -26259144.8
105.00 -21940206.5
92.50 -17621268.2
80.00 -9674421.8
67.50 -7514952.6
55.00 -5355483.5
42.50 0.0
30.00 0.0
σ
y [cm] [Kg/c C [Kg] M [Kg·cm]
m2]
155.00 -68.2 43109.75 36983894.50 133.75
142.50 -69.7 39665.14 30943812.15 121.25
130.00 -71.3 40531.50 25472742.03 108.75
117.50 -72.8 41397.86 20489905.45 96.25
105.00 -74.4 42264.22 16006131.91 83.75
92.50 -75.9 43130.58 12032250.92 71.25
80.00 -77.4 43996.94 8579091.99 58.75
67.50 -79.0 44863.30 5657484.63 46.25
55.00 -80.5 45729.66 3278258.36 33.75
42.50 -82.1 68340.83 1452242.67 21.25
30.00 -83.6 0.00 0.00
7.14.3.-Momento total
y [cm] M [Kg·cm]
155.00 -12770274.62
142.50 -12331949.53
130.00 -11324612.21
117.50 -5769239.36
105.00 -5934074.61
92.50 -5589017.31
80.00 -1095329.78
67.50 -1857468.00
55.00 -2077225.13
42.50 1452242.67
30.00 0.00
7.14.4.-Dimensionamiento de la armadura
Momento positivo
T = -17868.6 Kg
Ø = 10 mm
#E = 14 estribos
Ats = ### cm 2
< At = 21.99
Adopto: 1 EØ 10 mm c/ 5.00
Momento negativo
T = 109851.82 Kg
Ø = 16 mm
#E = 14 estribos
Ats = 78.5 cm2 < At = 56.30
Adopto: 1 EØ 16 mm c/ 5.00
SFORZADO.
igas presforzadas
m
m (4 Carriles)
2.00 m
1.80 %
4" c/ 2.00m a c/lado
olocarán aristas de 2cmx2cm
Kg/cm2
Kg/cm2
cm
cm
6.67 cm
ipo Freyssinet
eyssinet K201
cabezales, pilotes
Kg/cm2
Kg/cm2
cm
cm
I
2.4369
-4.1036
un calculo de la ashto
giendo el menor de 30%
ado necesario
As = 10.47 cm2/m
corrugado de distribucion
67% y el valor de %Asrep1
As = 7.85 cm2/m
As = 3.93 cm2/m
1.29 0.70
m m
1.50 0.25
m m
S=
2.50
m
0.08
m
0.44
m
0.38
m
0.38
m
Carpeta de 0.25
rodadura m
t = 0.15
m
0.15
m
0.08
m
0.10
m
0.84
Kg·m/m
As = 7.14 cm2/m
As = 5.24 cm2/m
As = 5.24 cm2/m
Kg·m/m
As = 3.93 cm2/m
As = 5.24 cm2/m
Viga I, tipo IV según la AASHTO
238751.96 Kg/cm2
2039000.00 Kg/cm2
307938.40 Kg/cm2
1900000.00 Kg/cm2
es (12V½"). Grado 270 ksi
1.27 cm
11.87 cm2
6.67 cm
cm2
t b1
2
h1
3
h2
1
h3
4 h4
5
h5
t b2
B2
m
cm
57.17 cm
Y’sc=41.17cm
Y’sc=41.17cm
3.83 cm
= 17.2651tn
= 17.2651tn
24
-6
30
11.42
cm3 O.K. !!!
cm3 O.K. !!!
12
torone
s
3.00 cables
Kg O.K. !!!
O.K. !!!
O.K. !!!
Px [Kg] ΔP [Kg]
170006.05 10269.71
169704.05 10571.72
169402.58 10873.18
Kg/cm2
O.K. !!!
O.K. !!!
O.K. !!!
O.K. !!!
O.K. !!!
O.K. !!!
M [Kg·m]
sec 2 sec 3 sec 4
x=0.63m x=1.13m x=6.25m
10383.9 18215.7 78372.1
5463.94 9641.73 42774.1
2762.59 4868.78 21250.7
18610.4 32726.2 142396.93
0.00
0.00
0.00
0.00 P
0.00 Kg·m
0.00 Kg·m
0.22
0.22
0.00 Kg·m
0.66
0.56
0.47
1.34 P
9724.4 Kg·m
14218 Kg·m
0.22
0.22
17405 Kg·m
1.11
0.94
0.78
2.24 P
16270 Kg·m
23789 Kg·m
0.22
0.22
29121 Kg·m
5.23
4.26
3.30
10.32 P
74916 Kg·m
109538 Kg·m
0.22
0.22
134088 Kg·m
O.K. !!!
cm
cm2 NO CUMPLE
cm
3.33375
0.033338
y3
SPLINE 0,-0.502500221668637
SPLINE 0.5,-0.501552999200116
SPLINE 1,-0.498711331794554
SPLINE 1.5,-0.493975219451951
SPLINE 2,-0.487344662172306
SPLINE 2.5,-0.478819659955619
SPLINE 3,-0.468400212801892
SPLINE 3.5,-0.456086320711122
SPLINE 4,-0.441877983683312
SPLINE 4.5,-0.42577520171846
SPLINE 5,-0.407777974816566
SPLINE 5.5,-0.387886302977631
SPLINE 6,-0.366100186201655
SPLINE 6.5,-0.342419624488637
SPLINE 7,-0.316844617838578
SPLINE 7.5,-0.289375166251478
SPLINE 8,-0.260011269727336
SPLINE 8.5,-0.228752928266152
SPLINE 9,-0.195600141867928
SPLINE 9.5,-0.160552910532661
SPLINE 10,-0.123611234260354
SPLINE 10.5,-0.0847751130510049
SPLINE 11,-0.0440445469046144
SPLINE 11.5,-0.00141953582118262
SPLINE 12,0.0430999201992907
SPLINE 12.5,0.0895138211568054
142396.93
DETALLE ARMADO a [cm] b [cm] c [cm] d [cm] e [cm] total [cm]
a d
1 Ø 10 mm c/ 15.00 cm 5.00 8.00 14.00 33.00 - 60.00
cantidad Peso [Kg]
280.00 1310.44
280.00 1310.44
125.00 314.82
140.00 624.92
187.00 3227.04
50.00 771.91
8.00 123.50
10.00 154.38
280.00 349.13
187.00 69.18
TOTAL : 8255.75
279.40
139.70
#DIV/0!
139.70
186.27
186.27
186.27
186.27
279.40
186.27
LONGITUD BÁSICA
Resistencia m
característica del
hormigón [Mpa] B400S B500S Ø =
25 12 15
30 10 13 Ib1 =
35 9 12
40 8 11 Ib =
45 7 10
50 7 10
Longitud de
Tracción Compresión As =
anclaje
Prolontación recta 1 1 Asreal =
Patilla, gancho y
0.7 1 β =
gancho en U
Barra transversal
0.7 0.7
soldada
Ib,neta =
EMPALME DE ARMADURAS
Distancia entre los Porcentaje de barras solapadas trabajando a tracción, con relación
empalmes más a la sección total de acero
próximos 20 25 33 50
a ≤ 10·Ø 1.20 1.40 1.60 1.80
a > 10·Ø 1.00 1.10 1.20 1.30
α = 1.00
IS = 10.47 cm
10 mm
15.00 cm
12.56 cm2
12.60 cm2
0.70
10.47 cm