Foreword

Between the last edition of our catalog and this, Amici has been
successful in promoting energy efficient heating systems. With
the help of partner organizations like the Hotel Engineers
Association of the Philippines (HEAP) who share our vision to
promote energy management best practices, we were able to
execute our seminar "Water Heating Systems: Towards Energy
Conservation" twice in Manila and one in Cebu. To everybody who
participated in the information dissemination of energy efficient
water heating, we should be proud of ourselves. Cheers.

This year, we are even more intent in promoting new


technologies such as Templifier system (see pages 6-7) to bigger
establishments with centralized cooling.

At the same time, we seek to maintain our participation in


promoting energy efficient water heating through seminars and
elevate further the level of service that we have provided our
clients.

We are proud of our long list of clients using our Energy Efficient
Water Heating Systems. We hope you can also be our partner
towards energy efficiency and conservation.

2
Contents

Water Heating
4 Current Trends: Going Go Green
6 Current Trends: Templifier
8 Solar Heat Pumps
10 Commercial Heat Pumps
12 Residential Heat Pumps
14 Solar Water Heaters
17 Commercial Storage Tanks
19 Commercial Gas Water Heaters
21 Hot Water Boilers
23 Residential Electric Water Heaters
24 Residentail Gas Water Heaters
25 Circulators and Flow Switches
26 Shower and Multi-point Instant Water Heaters

Swimming Pool and Spa


27 Pool and Spa Pumps
29 Pool Filters
30 Pool & Spa Accessories
32 Pool Heaters

Water Systems
33 Jet Pumps
35 Booster Pumps and Centrifugal
39 Pumps
41 Sewage Pumps
42 Submersible Pumps
Pressure Tanks

Miscellaneous
44 Water Heating Operating Costs
45 Water Heater Sizing
46 Pool Heater Sizing and Installation
47 Pool Chemical Guide and Spa Layout
48 Conversion Tables
50 Pipe Friction
Going. Go. Green.
Amici Water Systems joins the world in the global race in Going Green. Amici is dedicated
to finding eco-friendly products and solutions for the sustainability of the planet. This 2010,
Amici is excited to present its green technologies for different water systems applications:
Water Heating, Swimming Pool Equipment and Pressure Systems.

Water
Heating
TEMPLIFIER: McQuay TGZ Templifier water heaters use a
unique technology to recover large amounts of heat that wou
typically be rejected from the building and then use that hea
for processes, building heat, or domestic hot water. The nam
says it all: Temperature Amplifier — Templifier. For more o
templifiers, see pages 6-7.

HEAT PUMPS: Fireflux Heat Pump Water Heater


(HPWH) is a
promising technology that uses the same mechanical
principles as refrigerators and air conditioners to
generate hot water. unlike conventional electricity
and fossil-fuel-fired water heaters, HPWH's take heat
from the surrounding air and transfer it to the water in
the tank. Browse through pages 9-13 for more
information on HPWHs.

GAS HEATER: The A. O. Smith Cyclone Xi is the


industry’s most technologically advanced
commercial water heater. With up to 96% thermal
efficiency, Cyclone Xi provides outstanding hot water
output, with dramatic savings on operating costs
compared to units with standard 80% efficiency. A.
O. Smith’s leading-edge engineering delivers
conventional power-vent or sealed combustion power
direct-vent versatility, low-NOx emissions, and
excellent space-saving characteristics. See pages 19-
20 for more information.

SOLAR WATER HEATER: Our SolarActive Water Heaters


harness the sun's energy to provide hot water. This system can
drastically reduce your water heater operational costs, saving
you money. SolarActive flat solar collector panels are especially
suited for the Philippines' tropical sunlight. See pages 14-16 for
further information.
CONSTANT PRESSURE SYSTEM: Amici provides
a wide range of customized package booster
systems from constant pressure switch operations
to variable frequency drives for efficient water
management.

Edsa Shangri-la Hotel, Garden Wing

SWIMMING
POOL POOL PUMP: A breakthrough in energy-efficiency and
service life, the IntelliPro® Variable Speed Pump allows
programming for four different speeds for different pool,
spa or water features applications. Pump speeds are
easily adjusted with the push of an up or down arrow
button. Standard pool pumps can consume as much
energy as all other home appliances combined. Sta-rite
IntelliPro® pumps can cut energy use up to 90%,
generally saving in utility costs annually. Browse
through page 25 for more information.

POOL HEATER: Features include an LED temperature readout


with dual thermostat controls, temperature safety lockout, and
6-position control panel. PMG burner technology requires no
outdoor draft hood. Proven Dura-Glas® rust-proof construction
with plastic manifold and PVC union connections. Heavy-duty
unit with cupro-nickel exchanger stands up to the harshest of
applications, like low pH, high flow or heavy use. An Eco
Select™ Choice: Max-E-Therm® high performance heaters offer
best-in-class energy efficiency. Plus, they are certified for low
Nox emissions, making them eco-friendly favorites. See page
27 for more information.

UNDERWATER LIGHTS: LED lights use less


amount of energy compared to regular lights
among lighting options. Jet-flo and Sta-Rite pool
lights need only 7-15 watts to create the same
light output as traditional incandescent and
halogen pool lights at 75-150 watts- more than
85%. LED lights are more durable and can last
longer. More designs of underwater lights on
page 28.

With rising gas prices and global warming, environmental and energy
concerns has rapidly grown over the last few years. In line with this, Amici
comes up with seminars to introduce technologies that helps our environment.
Amici is committed to providing your water equipment solutions that
contribute to a cleaner world.
TEMPLIFIER
McQuay International delivers engineered, flexible solutions
for commercial, industrial and institutional HVAC
requirements with reliable products, knowledgeable
applications expertise and responsive support. Since 1872,
as a pioneer in the manufacture of the steam engine,
McQuay International has been providing quality equipment.

Reduce your energy costs and minimize your


carbon footprint with the TGZ Templifier™
Water Heater.
Templifier units can produce up to 160 °F water for
use in
service hot water heating or reheat applications.
Units have been installed worldwide in hotels,
hospitals, offices and factories. Both HVAC and
process applications can reduce energy costs by
using a Templifier water heater.
Model TGZ Templifier units with scroll compressors
are available in 600 to 3,100 MBh capacity.

HVAC Applications: space heating, service hot


water, reheat / dehumidification, outside air
heating.

Building / Facility Uses: hospitals, hotels, fitness


centers / gyms, laundry services, swimming pools,
kitchens, etc.
Model TSC Centrifugal Templifier Water
Heater is available with capacities from 3,000
Process Applications: food processing, paper mills,
to 24,000 MBh.
textiles, process hot water, etc.
The TGZ Templifier unit is based on the McQuay line of scroll compressor packaged
chillers with benefits proven in a variety of building types and performance conditions.

Templifier Feature Benefit


Hermetic Scroll Reliable performance from a simple design. Inherently
Compressor low sound levels.
Open Choices™ Control Allows easy integration with your choice of building
Feature automation system using standard open protocols such
as LonTalk®, BACnet® or Modbus®.
R-134a Refrigerant No ozone depletion potential and no phase-out
schedule.
Optional Hot Gas Bypass Permits unit operation down to 10% of full load
capacity.
Energy Efficient Heat Reduces operating costs. Contributes toward LEED®
Recovery points by improving efficiency of the heating system.

6
TEMPLIFIE
TGZ Templifier
Model Heating COP
Capacity (MBh)

040 603 5.19

050 815 5.01

060 999 5.19

080 1393 5.45

100 1613 5.52

110 1854 5.56

120 2094 5.61

150 2419 5.52

170 2780 5.57

190 3142 5.61

NOTE: Capacity is based on 85° F leaving source


temperature, and a 10-degree temperature drop in the
evaporator. Leaving condenser water temperature is 140°F
with a 20-degree temperature rise. Maximum leaving
water for all TGZ models is 160°F.

McQuay scroll and screw chillers provide


heat at a lower cost than burning fossil
fuels and generate a very good return on
investment. It offers COPs (coefficients of
performance) of four to five, and often
pay for themselves in one year or less.
This innovative heat recovery technology
can reduce CO2 emissions by hundreds of
tons annually and significantly reduce a
facility’s carbon footprint. In addition,
Templifier water heaters can help building
owners earn LEED® points by improving
the efficiency of their heating systems.”

Because templifier units heat water more


economically than either fossil fuel or
electric-resistance heaters, they can
reduce the burden on boilers and/or
cooling towers, thereby eliminating or 3 units TGZ50 TR McQuay Templifiers,
delaying a capital equipment expense Radisson Hotel, Cebu City
when increased heat production is
needed.
7
Solar-Heat Pump System
Indeed, solar energy is free; but it's not there for 24 hours. Nor is it available 365 days a year.
Shangri-la Edsa knew this exactly. Instead of conventional solar heaters with electric element
backups, they committed to a solar heating system where the backup is the next best thing: Heat
Pump Water Heaters.

Hence, the first Solar-Heat Pump Water Heating System in the Philippines is installed.

The performance of the Solar-heat pump water heating system in Shangri-la Edsa is excellent. It is
not free as pure solar energy. It never is. But using heat pump as backup, it's as close to free as
it gets. Operating cost is reduced by more than 80%. Now all steam boilers of Shangri-la Edsa
have been shut down, except for a small capacity to serve steam and high temperature
requirements for kitchen and laundry.

40 units Solar Panels 2 units FF05 Heat Pump, 3 T350 Tanks, 2 units FF05 Heat Pump, 3 T350 Tanks,
Edsa Shangri-La, Tower Wing Edsa Shangri-La, Tower Wing Edsa Shangri-La, Tower Wing

Easily, the solar-heat pump water heating system became


popular to establishments with similarly large hot water
consumption like the Bolinao International Retirement Homes and
Marlowe Navigation.

6 units FF7.5 Heat Pump, 8 IT1000 Tanks,


Edsa Shangri-La, Garden Wing

Limitations of the Solar-Heat


Pump water heating systems Total 40 Panels, 1750 Gallons Storage, and 10 HP Heat Pumps in Bolinao International
are: large surface area Retirement Homes, Pangasinan
requirement for panels, large
installation cost and large
capital investment on
equipment.

“The solar-heat pump system


by design is a certainty of
savings put in effect”

Total 12 Panels, 700 Gallons Storage, and 2units of 2 HP Heat Pumps in Marlowe Naviga
8
Heat Pump
System
Although the solar-heat pump water heating system is a very effective and efficient water
system, heat pump water heating system alone has grown to be even more popular given the
heating

cheap operating costs, 24 hour availability, at a relatively smaller investment and foot print.

Heat Pump Water Heaters, the heart of the Solar-Heat Pump System operate so efficiently that it is
common and reasonable for retrofitting working electric and gas heaters and boilers.
Establishments who have previously used gas-fired heaters that have now shifted to heat pump
water heaters are the following: Victoria Court hotels (Malate, Cuneta, Gil Puyat, Las Pinas,
Balintawak, North Edsa, Malabon, Escarpment, Hill Crest, Canley and San Fernando Pampanga),
Astoria Plaza and Sogo hotels (Novaliches, Cubao, Kalentong, Sta. Mesa, Recto, Harrison, Pasay,
Bacoor Cavite, San Pedro Laguna, Guadalupe, Alabang).

1 unit FF05 Heat Pump, 5 HP 3 units, Water to Water Heat Pump, 4 units FF05 Heat Pump, 5 HP
Victoria Court, Canley 15HP, Radisson Hotel, Cebu Sogo Hotel, Harrison

Likewise, new establishments have started investing on these efficient heat pump systems in
view of the rising cost of electricity and gas: Sogo Hotels (Cainta, Quirino, Pampanga, North
Edsa), Eurotel (Makati, North Edsa, Pedro Gil), Parcvue Hotel, Microtel Cebu, Club Ultima Cebu,
Lewis Hotel Angeles City, Elephant Island Marinduque, Hamilo Coast Beach Resort Batangas,
Tagaytay Hospital, College of Saint Benilde Hotel, Marlowe Navigation, Benguet Pines Hotel.

2 units FF10 Heat Pump, 10 hp 5 units FF02 Heat Pump, 2 hp 4 units FF02 Heat Pump, 2 hp
Hamilo Coast Beach Resort, Batangas Sogo Hotel, Pampanga Sogo Cubao

Apart from potable water heating, heat pump water heaters


have also become a suitable choice for heating swimming
pools. Because heating such large volume of hot water requires
a lot of heat energy, payback period of replacing gas/electric
swimming pool or whirlpool/spa heaters usually ranges from 2
to 6 months only.
If you have any questions, or you would like to request a
recommendation, feel free to contact us. Let's think of ways
to make your business grow more profitable.
1 unit FF10 Heat Pump, 10
hp Canyon Woods, Tagaytay

9
Commercial Heat Pumps

Heat Pump Water Heater (HPWH) is the proven technology that


uses the same mechanical principles as refrigerators and air
conditioners to generate hot water. Unlike conventional
electricity and fossil-fuel-fired water heaters, HPWHs take heat
from the surrounding air and transfer it to the water in the tank.

The heat pump works by taking


heat from the surrounding air and
using it to heat the low pressure
liquid refrigerant in the heat
pump's evaporator, vaporizing the
liquid. The refrigerant then passes
through the compressor, which
raises the refrigerant pressure and
thus the temperature as well. The
heated refrigerant gas passes
through the heat pump condenser,
where it gives off its heat to the
water and condenses back into the
liquid state. The liquid refrigerant
now passes through an expansion
valve where the pressure is
reduced and the cycle starts over.
Commercial Heat Pump Water Heating System
Heat pumps mainly consist of a
compressor, fan, evaporator and Heat Pump Features
the heat exchanger. The Refrigerant R22 or R417A
compressor requires electricity to Copeland / Hitachi scroll
compress the refrigerant and Compressor
(National rotary for FF-02)
vaporize it, and the fan requires a J acket Stainless 304 steel plate
small amount of electricity to User Interface LCD display control panel
continually blow air across the
Heat Exchanger Copper tube heat exchanger
evaporator coils when the unit is
System protection
operating. The only electricity cost Automatic unit on/off timer clock;
features
is the operation of the compressor Insufficient water flow protection;
and the fan in order to collect the High/low pressure protection
free heat and pump it to the hot
Expansion Valve Alco (USA) expansion valve
water.
Certifications CE Mark; UL Listing underway
Commercial Calorifer Tank Features
Manufacturer A.O. Smith Water Products
Made USA
Construction ASME construction on all tanks greater
than 350 gallons capacity
Inner Tank Lining All internal surfaces exposed to water are
glass-lined per ASME HLW code procedure
NSF approved glass lining compound
Additional Protection Cathodic protection (anode rods) provided
Storage Capacity From 120 to 12,500 gallons
Copeland scroll compressor Operating Pressure 125 – 150 psi, ASME certified
Certifications NSF; ASME
10
Commercial Heat
Model FF-02
Product Specifications
FF-03 FF-05 FF-10
Pumps
FF-20
Outlet Water Rated Temp (°C) 60
Heating Capacity (kW) 6.9 10.6 17.1 35 70
Rated Power Input (kW) 1.82 2.8 4.5 9.2 18.4
Power Supply (V/ Ph/ Hz) 230/1/60 230/1(3)/60
Compressor Type National Rotary Copeland Scroll (USA) or Hitachi (Japan)
Compressor Quantity 1 1 1 2 2(4)
Cabinet Material 304 Stainless Steel Plate
Refrigerant Flow Restriction Alco Thermal Expansion Valve (USA)
Refrigerant Type R-22A / R-417A
Pipe Size (in.) ¾” 1” 1” 1 ¼” 4”
Dimensions: Length (in.) 1148 830 830 1500 1450
Width (in.) 456 710 710 745 1450
Height (in.) 580 885 1085 1085 1700
Ambient Air Range -20°C – 45°C
Air Discharge Direction Side Top Top Top Top
Weight (kg) 70 115 150 280 560
*For Titanium Heat Exchanger for use in swimming pool heating, change model code from FF to FFP (example: FF-05
to FFP-05)

4 units FF10 Heat Pump Water Heaters, Parcvue 2 units FF05 Heat Pump Water Heaters, Kamagong Inn
Hotel,
Alabang
Other establishments that have invested in
Fireflux Heat
Pumps Water System: Hamilo Coast Clubhouse
Batangas, Hollywood Hotel Baguio, Robinsons
Tagaytay Summit Ridge Hotel, Sogo Hotel Dau
and Cabanatuan, Fairmont Hotel.

Certifications to assure quality and


dependability:

2 units FF10 Heat Pump Water Heaters, Club Ultima,


Crown Regency Hotel and Towers, Cebu
11
Residential Heat Pumps
In 2006, Amici launched its line
of Commercial Solar Heat Pump
Water Heating System. This
technology uses the heat in the
air created by solar energy and
transfers it to the water used in
showering and bathing.
Instantly, this technology
became the direction in
commercial heating systems
because of its very efficient
operation, its 24-hour
availability, and its positive
effect to the environment by
reducing electric or otherwise
fossil fuel consumption.

Amici has installed this system


to already more than 50
commercial establishments *diagram of how a Residential Heat Pump works
nationwide of the highest
standards in a span of 2 years.
These include Edsa Shangri-la Residential Heat Pump
Hotel, Victoria Court hotels, Heating Capacity 4.7 KW
Hotel Sogo, Crown Regency Rated Power Input 1.2 KW
Hotel and Towers Cebu and Club Electrical Supply 220V / 1Ph / 60Hz
Ultima Cebu, Astoria Plaza Hotel Cabinet Material Powder Coated Steel
Ortigas, Canyon Woods Heat Exchanger Double Wall
Tagaytay, Microtel Cebu, Circulator Brass Integral
Elephant Island Marinduque, Refrigerant R417A
among others. Dimensions (LxWxH mm) 930 x 350 x 550

How does this work? A.O. Smith Calorifier


50 Gallons (54” x 20.5”) EES-50 / ECT-52
Heat Pump Water Heater 80 Gallons (58” x 24.5”) EES-80 / ECT-80
(HPWH) is proven technology Inner Tank Glass Lined
that uses the same mechanical Meeting / Exceeding
principles as refrigerators and Insulation ASHRAE Standards
air conditioners to generate hot Temperature & Pressure Relief Valve ASME Rated
water from the residual energy Other Standards UL Listed
in the atmosphere. Unlike
conventional solar panels,
HPWHs can take solar heat from
the atmosphere 24 hours a day,
365 days a year because it does
not require direct contact with
sunlight.

Edsa Shangri-la Crown Regency Hotel and Towers Canyon Woods, Tagaytay
Hotel Cebu
12
Residential Heat
Guaranteed Savings
Yearly Operating Cost for Home of 6
Using Solar Flat Collector Panels, the
energy that can be saved is limited
100000
by the duration by which sunlight
directly heats the solar panels. Solar 90000
Heat Pumps however use the
refrigeration technology to force free 80000
heat from the infinitely vast 70000
atmosphere into your showers day
and night. This allows Solar Heat 60000
Pumps to produce almost 20 times
50000
more hot water from solar heat

Pesos
compared to a conventional single 40000
panel solar heater.
30000
For example:
20000
A household with 6 members can
consume as much as 180 gallons per 10000
day. This translates to about Php
8,200.00 per month or about Php 0
Solar heater with Electric Backup
98,400.00 a year to your electric bill. Electric Water Heater Solar Heat Pump
On the other hand, with the use of Heater Type
Solar Heat Pumps, this translates to Yearly O perating Cost
only about Php 24,670.00 a year.
Hot Water Production Utilizing Heat from Solar Energy
1 Panel Conventional Solar 35 Gallons per Day *Assumptions:
2 Panels Conventional Solar 70 Gallons per Day Electricity is Php 9.00 per kwh; 1
3 Panels Conventional Solar 105 Gallons per Day Solar Panel saves 6 kwh per day;
Fireflux Solar Heat Pump Water Heater 658 Gallons per Day 2 GPM hot water mix on shower.

HOT WATER CONSUMPTION PROFILE OPERATING COST PER YEAR (PESOS)


Size of KWH Yearly
Baths per Gallons Gallons Per Electric Solar Heater Solar Heat
Household Shower Consumption Savings
Day per Day month Heater (2 Panels) Pump
(Persons) per Year
4 1.5 10 minutes 120 3600 609.14 65787.28 26367.28 16446.82 49340.46
5 1.5 10 minutes 150 4500 761.43 82234.1 42814.1 20558.53 61675.58
6 1.5 10 minutes 180 5400 913.71 98680.93 59260.93 24670.23 74010.69
8 1.5 10 minutes 240 7200 1218.28 131574.57 92154.57 32893.64 98680.93

Cost to produce 1000 Gallons of Hot Water Using Various Technologies

1,600
Cost per 1000
Heat Source Gallons of Hot
1,400 Water
1,200 Electric Heater 1,438
LPG Heater 898
1,000
Solar Heater (Electric Backup) 719
800 360
Solar Heat Pump
600

400
*Solar Heat Pump Water Heaters save
up to 75% of costs as compared to
200 electric heaters. With the continuous
0 increase in prices, investing in this
LPG Heater Solar Heat Pump system will reduce household electricity
Electric Heater Solar Heater with Electric Bakup
costs.
Cost per 1000 Gallons
of Hot water
13
Solar Water Heaters

SolarActive System
(Panels on the roof, Tanks are
hidden)
Solar Water Heaters do
not have to look so
heavy on the roof...

With Amici SolarActive


water heaters, only the
collector panels stay on
the roof. It is lighter on
the roofs, and doesn't Temperature Differential
greatly affect the Controller Active Solar Water Heating
architectural design. Diagram

Choice of Electric or LPG


Backup
A.O. Smith Residential Units
Glass-lined tanks, UL listed, foam insulated meeting/exceeding ASHRAE requirements.
Available in 50 gallon, 80 gallon, and 120 gallon models with electric backup; Available in
75 gallon, and 100 gallon models with LPG/Gas Backup.

A.O. Smith Commercial Hot Water Storage Tanks


Up to more than 10,000 gallons of hot water storage capacity for large volume centralized
solar heating systems. (For large volume solar heating systems, please consult distributor
for sizing and specifications.)

14
Solar Water
Heaters

24 units Flat Plate Collectors, Bolinao Retirement 5 units 350 gallon Storage Tanks, Bolinao
Homes, Pangasinan Retirement Homes, Pangasinan

Product Specifications
Storage # of Collector Panel Panel Weight Storage Height Diameter
(US Gal.) Panels Area (m2) (kg) Model (in.) (in.)
50 Gallons 1 2 39 EES-50 54 20.5
80 Gallons 2 4 78 EES-80 58 24.5
120 Gallons 3 6 117 ECT-120 64.25 28
75 Gallons 2 4 78 EMG-75 LPG 58.75 25.75
100 Gallons 2 4 78 FCG-100 LPG 68.5 28

Hot Water Storage Tank Solar Recirculating Pump


Manufacturer: A.O. Smith Water Products Casing: Cast Iron Casing / Bronze
Non-CFC foam insulation; meeting/ Cartridge: Stainless Steel
Insulation: exceeding ASHRAE requirements for Impeller: Non-Metallic
standby heat loss Shaft: Ceramic
150 psi working pressure; tested up Bearings: Carbon
Pressure:
to 300 psi Maximum Fluid
Sacrificial Anode 230 °F (110 °C)
included Temperature:
Rod: UL Listed
Glass-lined, fused to steel by firing
Internal Tank
at a temperature range of 1400 to
Construction: Solar Temperature Differential Control
1600 °F
low watt density 1” screw-in type, collector temperature; top and
Heating Elements: with Incoloy sheath bottom tank temperatures; error
LCD display:
reports, specific sensor failure
Temperature &
reports; 24 time display formats
Pressure Relief included; ASME rated
Valve: for circulating pump, valves, alarms,
4 Relays:
UL Listed and others
Temperature widely adjustable temperature ranges
Flat Collector ranges: for each of the 13 functions
Working Pressure: 170 psi audible alarm and flashing display on
Error alarm:
Copper Fins / Black Chrome errors
Collector Fins:
Absorber function and error reference listed on
Quick reference:
Suitable for raising the front panel
140 – 150 °F (60 – 65 °C)
temperature to: Power
Low 3VA
Copper Manifold and Risers; consumption:
Collector Material:
Aluminum Casing

15
Solar Water Heaters
Product Principle

Wall Hung Solar Water Heater


• Balcony mounting installation is applicable
for several kinds of balconies, overcoming the
lack of rooftop space often encountered in
high-rise applications.

•Innovative spherical surface heat exchanging


design and inside-sleeve water flowing
designing. Even in cold winter only one-day
sunshine can heat the large volume of water
to 50-degree fast. Meanwhile, the innovative
overheat protection can effectively prevent
water overheating in summer.
•Split pressurized designing, strong water flow, stable and comfortable water
temperature for heatlhy bathing.

Suggested Users
High rise, Medium high rise and Multi-storey apartment

Installation
Solar collector balcony mounting installation; Water tank wall hung installation

Application
System
Tank Outlet G1/2”
Rated Water Pressure (Mpa) 0.8MPa
Voltage (V) / (Hz) 220~240VAC 50/60Hz
Input (Kw) 2000
Circulation Style Natural; No Pump
Contour Aperture Area (m2) 2.05
Heat Transfer Fluid Water or Antifreeze
Solar Collector All-glass Evacuated Tube
Evacuated Tube Size (mm) Φ58x2100 (14x)
Inner Empty Glass Tube (mm) Φ30x2100 (14x)
Collector Dimension (mm) 2300 x 1170 x 160
Wind Resistance (m/ 2) 30 (11 Level)
Collector Inner Tank SUS316L
Heating Exchanger Material SUS316L
Air Collector Spud G1/2”
Over Heating Protection Radiator

16
Commercial Hot Water Stora
A.O. SMITH IS THE BEST CHOICE FOR
COMPLETE COMMERCIAL WATER
HEATING AND STORAGE SYSTEMS

No other manufacturer gives plumbing


professionals a broader choice of innovative
commercial water heaters and boilers. So, it
makes sense that when you need
supplemental storage of hot water, you can
turn to A. O. Smith for a nearly unlimited
selection of storage tanks.

A.O. Smith can deliver from 80 to 10,000


gallons of hot water storage / calorifier tanks!

A.O. Smith Direct Hot Water Storage Tanks


A.O. SMITH GIVES YOU
Nominal Overall Approximate
Diameter OPTIONS FOR DIRECT HOT
Model Capacity Length Shipping
(in.) WATER TANK APPLICATIONS
(US Gal.) (in.) Weight (lbs)
T350S 350 87.5 36 695 ● Up to 10,000 gallons
T400A 400 97.13 36 775 ● ASME construction
TL500A 500 121.75 36 841 ● Military specifications

TN500A 500 88 42 865 ● Manholes

T500A 500 73 48 951 ● Hand holes

750 105.88 48 1287 ● Lifting lugs


T750A
1000 137.75 48 1655 ● Steam or hot water tank heaters
T1000A
HD48-1250 1250 159 48 2067 ● Special and additional tank
HD48-1500 1500 190 48 2335 openings
● Ring and leg bases
HD48-1750 1750 220 48 2748
● Horizontal tank saddles
HD48-2000 2000 250 48 3150
● Factory-mounted T&P gauge
HD54-2250 2250 224 54 3269
HD60-2500 2500 204 60 4069 ● Manufactured in Renton,
Washington
*For other tank diameters and capacities up to 10,000 gallons, Please consult
distributor.

A.O. SMITH GIVES YOU


A.O. Smith Indirect Calorifiers OPTIONS FOR INDIRECT
Nominal Overall
Diameter
Approximate HEATING APPLICATIONS
Model Capacity Length Shipping
(in.) ● Up to 3000 gallons
(US Gal.) (in.) Weight (lbs)
79 53.96 28.34 281.6
● Jacketed and insulated
IT-300 ● Glass-lined heat exchangers
IT-500 132 80.29 28.34 420.2
● Indirect calorifier gives system
IT-750 198 79.9 35.82 583
protection from scaling, and
IT-1000 264 78.72 41.72 765.6
contamination between potable
*For dual coil, add S to model such as IT(S)-300 water and heating system
**For other sizes, please consult distributor ● Manufactured in Veldhoven

Plant, Netherlands

17
Commercial Hot Water Storage Tanks
A.O. SMITH GLASS LINING SETS THE STANDARDS
For long tank life, nothing matches the quality of A. O. Smith's PermaGlas coating, standard
on all our Stock Tanks and one of your many choices on Custom Tanks. Permanently bonded
to all inner tank surfaces at 1600°F, PermaGlas provides truly superior protection against
corrosion. And every A.O. Smith glass-lined tank is further protected against corrosion by
single or multiple magnesium anode rods.
Advanced Tank Design & Glass Lining Technology

Almost every commercial water heater made has a glass lined tank to protect against
corrosion and leaks. But only A. O. Smith can protect its premium heaters and tanks with
exclusive PermaGlas Ultra Coat.

1. 2.

The process starts when the bare tank PermaGlas Ultra Coat, in “slush” form
components (including the tank shell, is then poured into the completed
heads and bottoms and the heat tank. The tank is then sealed and
exchanger) are welded together before rotated in several directions, to allow
application of PermaGlas Ultra Coat the coating to precisely cover all
water-side inner tank surfaces, and the
interior of the heat exchanger

3. 4.

Excess PermaGlas slush-coating The slush-coated tank is then run


material is then drained from the tank through a 1,600 °F enameling furnace,
which permanently bonds PermaGlas
Ultra Coat to the steel

CERTIFICATIONS TO ASSURE ASME


QUALITY AND DEPENDABILITY: NSF
18
Cyclone XHE Commercial Gas Wate

Introducing the World's First


96% Efficient Water Heaters

The original Cyclone XHE line (BTH-120 through


BTH-250) set standards for performance and quality
that still stand. 94% thermal efficiency. Multiple
venting options. Space-saving, time-saving
installation versatility.

Now, with an unprecedented 96% thermal


efficiency, the Cyclone BTH-300 and BTH-400 raise
the bar yet again. The newest Cyclones combine
130 gallon storage with 300,000 and 400,000 BTU
inputs. By manifolding multiple units together,
total storage and recovery can be increased
dramatically.

The Cyclone XHE far surpasses federally mandated


ASHRAE standards for heat loss and complies with
CEC Title 24. Top and bottom insulation and a
sealed submerged combustion chamber reduce
heat loss to an absolute minimum. 96% thermal
efficiency allows Cyclone BTH-300 and BTH-400 to
provide total investment recovery in as little as two
years.

The expanded Cyclone line gives you a commercial


water heater choice for mid-sized restaurants and
50-300 room hotels, with significant advantages
over both standard systems and boiler installations.
And breaking the 96% barrier truly does make
Cyclone the most efficient water heater line ever
built.

Cyclone XHE Commercial Gas Water Heaters


Storage Input Height Diameter Depth Inlet/ Outlet Shipping Wt.
Model
(US Gal.) (Btu/ hr) (in.) (in.) (in.) (in.) (lbs)
BTH-120 60 120,000 55.5 27.75 30 1½ 380
BTH-199 100 199,000 74.5 27.75 30 1½ 438
BTH-250 130 250,000 75.5 27.75 --- 1½ 555
BTH-300 130 280,000 74 33.13 39.13 1½ 900
BTH-400 130 400,000 74 33.13 39.13 1½ 900

19
Cyclone XHE Commercial Gas
Water Heaters
The intelligent control system, with easy-to-
navigate menu, provides precise temperature
control and unit operating information.

Total Control (Cyclone Xi LCD)


● Detailed heater status information: Blower, igniter, igniter
current, valve, flame detection, air inlet restrictions,
exhaust vent restrictions, acceptable gas supply
pressure
● Precise temperature setting with actual tank temperature

at upper and lower probes


● Alerts the user to any potential corrosion-related leak

● Maintains constant log of the number of cycles and burner

operating time
● Communicates fault details and gives diagnostic

information
● Maintains a log of any fault occurrence and the time a

fault occurred
The A.O. Smith powered anode system provides the most modern
and innovative technology available to provide long-lasting tank
protection.

Powered Anodes *
* Not on 76,000 and 100,000 BTU models.

● Non-sacrificial anode does not require maintenance or


inspection
● Provides superior tank protection to traditional aluminum

or magnesium anodes
● Power level adjusts to changes in water conditions for

optimum protection
● Offers superior protection in various water conditions: 1.

Better protection in water with low conductivity, 2.


Eliminates the occurrence of hydrogen sulfide gas
production (rotten egg odor)

Strength in Numbers

Cyclone XHE water heaters can be


installed in manifolded multiples to
serve the highest demand applications
in place of boiler systems. For example,
four (4) BTH-500s can be manifolded to
provide total storage of 520 gallons and
inputs of 2,000,000 Btu.

20
Hot Water Boil
84% EFFICIENT, LOW Nox Hot
Water Supply Boilers
A. O. Smith Genesis boilers offer everything you could ask for in a non-condensing boiler. They
provide the highest possible 84% thermal efficiency, outstanding venting flexibility, space-saving
stackable designs and a new advanced Energy Management Control (EMC) system.

Genesis Hot Water Boiler


Input Height Diameter / Depth Inlet/ Outlet Exhaust Air Inlet Gas Pipe Shipping
Model Efficiency
(Btu/ hr) (in.) Width (in.) (in.) (in.) Vent (in.) (in.) (in.) Wt. (lbs)
GW-300 84% 300,000 33 45 26.5 1½ 5 5 ¾ 375
GW-500 84% 500,000 33 60 26.5 2 6 6 1 463
GW-750 84% 750,000 33 80 26.5 2 8 8 1 ¼ 575
*Models up to 2,500,000 BTU inputs are also available. Please consult distributor if interested.

NEW EMC-5000 ENERGY MANAGEMENT


CONTROL
● Patent pending

● Controls every electrical boiler function, including pump operation and main burner ignition
● Plus or minus 1 °F accuracy temperature management
● Display panel shows operating status and fault readings in easy-to-understand English
instead of confusing numeric codes
Display of temperature set points, outlet temperatures, current inlet/outlet differential
temperature and tank temperature

TWO-STAGE GAS FIRING SYSTEM


● Twin gas valve firing system ensures smooth operation, saves fuel and extends boiler life
● Prevents short cycling during low demand periods

SPACE SAVING DESIGN


● Compact “stackable” design packs maximum water heating power into minimum space

21
Commercial Water
Heaters
A.O. Smith offers over 500 different commercial models,
including gas-fired, oil-fired and electric configurations,
ranging in capacities from 5 gallons to 10,000 gallons, with
input range from 50,000 Btu with the equivalent of
2,5000,000 Btu.

Other Commercial Heaters Stocked in the Philippines:

Masterfit, The Classic Dura–Power Conservationist


Commercial Gas Heater Commercial Electric Heater Commercial Oil-Fired Heater
BTR-180, BTR-198 DRE-52, DRE-80, DRE-120 COF-315

Gas Fired
Shipping
Storage Input Height Diameter Depth Inlet/ Outlet
Model Wt.
(US Gal.) (Btu/ hr) (in.) (in.) (in.) (in.)
(lbs)
BTR-180 81 180,000 67.5 27.75 - 1½ 470
BTR-198 100 199,000 74 27.75 - 1½ 603

Electric
Shipping
Storage Max. Height Diameter Depth Inlet/ Outlet
Model Wt.
(US Gal.) Wattage (in.) (in.) (in.) (in.)
(lbs)
DRE-52 50 54,000 55.25 21.75 27.25 1¼ 245
DRE-80 80 54,000 59.35 25.25 31.25 1¼ 264
DRE-120 119 54,000 62.25 29.5 35.75 1¼ 375

Oil Fired
Shipping
Storage Input Height Diameter Depth Inlet/ Outlet
Model Wt.
(US Gal.) (Btu/ hr) (in.) (in.) (in.) (in.)
(lbs)
COF-315 84 315,000 74.75 - 37 1½ 557

 All Components, Commercial Grade  Designed for Temperatures up to 180 °F or


 Glass Lining, Commercial Grade 82 °C
 UL Listed  Heavy Duty

22
Residential Electric Water
Since pioneering the innovation of the glass-lined water
heater in 1936, A.O. Smith has continued to be the
leader in providing home owners and developers of
quality and value hot water heating systems.

UNDER THE LAVATORY MODELS


Element
Storage Height Diameter Shipping Wt.
Model Wattage at
(US Gal.) (in.) (in.) (lbs)
240V
EJC-6 6 2500 15.25 14.13 31
EJC-10 10 1650 / 3000 18.25 16 45
EJCT-20 20 2500 / 4500 31.5 16 62

WALL HUNG MODELS


Element Height /
Storage Diameter Shipping Wt.
Model Wattage at Length
(US Gal.) (in.) (lbs)
220V (in.)
EWH-10 2.64 1500 16 14.25 15.4
CEWH-40 10.57 2000 28.25 14.25 41.8
CEWH-60 15.85 2000 27.75 18.25 55
CEWH-80 21.14 2000 34 18.25 66

ENERGY SAVER MODELS


Element
Storage Height Diameter Shipping Wt.
Model Wattage at
(US Gal.) (in.) (in.) (lbs)
220V
EESR-15CA 15 2000 26.18 18.5 ---
EESR-20CA 20 2000 28.75 18.5 ---
EES-30 30 3800 /3800 37 21 94.6
EES-40 40 6000 / 6000 44 21 116.6
EES-50 50 6000 / 6000 53.75 20.5 132
EES-80 80 6000 / 6000 58 24.5 206.8

PROMAX MODELS
Element
Storage Height Diameter Shipping Wt.
Model Wattage at
(US Gal.) (in.) (in.) (lbs)
240V
ECS-30 30 6000 36.5 20.55 100
ECS-40 40 6000 / 6000 44 20.5 115
ECLN-40 40 6000 / 6000 31.5 23 120
ECT-52 50 4500 / 6000 54 20.5 125
ECT-80 80 4500 / 6000 60.5 24 200

23
Residential GAS Water
Heaters
Electric Water Heater Parts and Accessories
Heating elements vary in
material, structure,
wattage and voltage:

Material: Copper / Incoloy


Structure: screw / flange
type
Wattage: from 1.5Kw – 6Kw
Heating Element Thermostat Voltage: 220 – 240V /
specialized 380V

Save on operating costs! A.O. Smith LPG water heaters are


ideal for Dormitories, Hotels, Fitness Gyms, and applications
with large hot water requirements. Consult distributor for
computation and analysis.

ENERGY SAVER MODELS


Storage Input Height Diameter Shipping Wt.
Model
(US Gal.) (Btu/ hr) (in.) (in.) (lbs)
EMGL-30 30 36,000 48 18.25 105.6
EMGL-50 50 36,000 60.25 20 169.4
EMGL-75 75 67,500 58.75 25.75 323.4
GCV-30 28 40,000 59.65 16 112
GCV-50 50 40,000 60.88 20 160
GCV-65 67 65,000 65 24 215
FCG-75 81 75,100 61 26.5 275
FCG-100 81 75,100 68.5 27.75 350
Energy Saver Manufactured Housing Gas Water Heaters
● All models meet HUD requirements for manufactured housing
installation
● Available in standard vent or direct-vent design

● Convertible gas control for natural gas or propane operation

● Environmentally friendly Green Choice™ gas burner reduces Nox

emissions by 33% compared to standard burners


Tamper-Resistant Green Choice
Brass Drain Valve Low-NOX Burner
Reliable, quality brass drain Patented “eco - friendly”
valve with “screw-slot” head burner design reduces NOx
to help prevent valve emissions by up to 33% and
opening by curious complies with Southern
youngsters. California and Texas
requirements.
T&P Relief Valve PEX Dip Tubes
The temperature and
A.O. Smith's PEX cross-link
pressure relief valve is
polymer dip tubes are long-
factory-supplied and
lasting with superior
matched to the heater to
resistance to destructive
help ensure that every water
thermal oxidation.
heater is installed properly.
24
Circulators and Flow
Switches
Taco delivers exceptional quality because it has been owned and operated by the
same family for over 80 years. Taco's commitments to innovations in energy-
efficient systems, design software, training, and support is matched only by the
loyalty it extends to its employees, vendors, and customers.

Taco Industrial Flow Switches

 Fluorosilicone Seal
 250 PSI Maximum Service Pressure
 250°F Temperature Rating

 Stainless steel Paddles and Trip

Rods
 NEMA 1 and NEMA 4 Models

 For Use on 1” to 8” Diameter Pipe

 UL, CSA, CE Approved

00 Series Hot Water Circulators

 Bronze Construction
 Aluminum Stator
Housing
 Stainless Steel
Cartridge
 Non-Metallic Impeller

 Ceramic Shaft

 UL Listed

1400 Series High Capacity Hot water Circulators

● Bronze Construction
● Stainless Steel Face Plate, Steel Motor
Housing
● Non-metallic Impeller/ Brass Impeller Insert

● Solid Alloy Steel, Nu-Tride Coated Shaft

● Carbon/Silicon-Carbine Mechanical Seal

● Stainless Steel, Permanently Lubricated

Motor Bearings
● EPDM O-rings

● 150 PSI Working Pressure

● 225 °F Maximum Fluid Temperature

● UL Listed

● 1400-20B (1/6 Hp); 1400-50B (½ Hp)

25
Instant Electric Water Heaters
Atmor Electric Instantaneous Water Heaters, designed according to
Israel Standard Technology, supply continuous hot water as
needed. Unlike storage heaters, water is heated only upon use,
totally removing standby heat loss, and translating to savings on
your electric bill.
Single Point Instantaneous Water Heater
APPLICATION HOT SHOWER / SINGLE POINT OF USE
Temperature Selection Three-way temperature selection
Safety Auto-thermal cut-off; Automatic pressure relief ralve
Voltage 220-240 VAC
Power Rating 3.5 Kw
Cycles 50 Hz – 60 Hz
Phase Single Phase
Heat Setting Low: 1.5 Kw Med: 2.0 Kw High: 3.5 Kw
Cable Entry Top right and Top left
Circuit Breaker Rating 30 Amperes
Dimensions (H x W x D) 190 x 300 x 110 mm
Inlet / Outlet Connection 15 mm (½” compression inlet connection)
Flow Rate 4 Liters / Min (1.05 Gal / Min) @ 12oC Temp. Rise
Minimum Activating Pressure 1 BAR (14.5 PSI)
Operating Water Pressure 0.3 – 7 BAR (5 – 100 PSI)
Accessories Shower head set

Multi-Point Instantaneous Water Heater


SHOWER and SINK COMBINATION /
APPLICATION
MULTIPLE POINTS OF USE
Temperature Selection Three-way temperature selection
Safety Auto-thermal cut-off; Automatic pressure relief ralve
Voltage 220-240 VAC
Power Rating 5.5 Kw
Cycles 50 Hz – 60 Hz
Phase Single Phase
Heat Setting Low: 2.0 Kw Med: 3.5 Kw High: 5.5 Kw
Cable Entry Top right and Top left
Circuit Breaker Rating 30 Amperes
Dimensions (H x W x D) 190 x 300 x 110 mm
Inlet / Outlet Connection 15 mm (½” compression inlet connection)
Flow Rate 4 Liters / Min (1.05 Gal / Min) @ 20oC Temp. Rise
Minimum Activating Pressure 2.5 PSI
Operating Water Pressure 0.3 – 7 BAR (5 – 100 PSI)

Low Wattage Dual Heating Element


High Density Composite Plastic Heating Chamber

Automatic Pressure Relief Valve

Sensor

Low Flow Flow Switch 1.5 Psi


Power Relay
Discharge Hose (extending to outside the unit)
26
Swimming Pool and Spa
Pentair Water Pool and Spa® is the world’s leading manufacturer of
pool and spa equipment and accessories. Under it is the Sta-Rite®
brands which offers innovative products that make pool and spa
ownership simpler, more enjoyable, and more energy efficient than
ever before.

Sta-Rite Dura-Glass Pool Pump

Sta-Rite Dura-Glas Pool Pump


gpm
Suction Discharge
Model hp at 40 ft
(in.) (in.)
head
P2RA5CL ½ 40 1½ 1½
P2RA5DL ¾ 54 1½ 1½
P2RA5EL 1 70 1½ 1½
P2RA5FL 1½ 85 1½ 1½ A- P2RA5CL B- P2RA5DL C- P2RA5EL D- P2RA5FL

Max-E-Pro High Efficiency Pool Pump

Sta-Rite Max-E Series


gpm Suction Discharge
Model hp at 40 ft (in.) (in.)
head Unions Included
P6E6F-207L 1½ 128 2 2 F. P6E6FL / P6EA6G
P6EAG 2 128 2 2 G. P6EAAGL
P6EAAG 2½ 143 2 2 H. P6E6HL
P6E6H-209L 3 170 2 2

27
Swimming Pool and Spa Pumps
Sta-Rite Dura J et Spa Pumps with Air Switch
Number of Suction Discharge
Model hp
J ets (in.) (in.)
1 Ultra-J et 1 6-8 1 ½ 1½
2 Ultra-J et 1.5 8-10 1½ 1½
: 2 Dura-J et 2 10-12 2 2
3 Dura-J et 3 14-16 2 2
3.5 Dura-J et 3½ 16-18 2 2

IntelliPro VS-3050 Variable Speed


Pump
Save 30% - 90% of your electric bill due to your pool pump! Energy
Efficient, Long Lasting, Quiet

Permanent Magnet Synchronous Motor (PMSM), the same motor


technology used in electric cars, give a base saving of 30%,
compared to standard electric motors.

Variable Frequency Drive lets you configure your pool pump to


operate at the minimum speed required, for unsurpassed energy
saving and longetivity.

At 7 - 10 decibels, IntelliPro is quieter than a human whisper.

IntelliPro operates from 440 to 3560 RPM providing performance up


to 3 Hp or 160 gpm.

Jacuzzi offers luxury product lines of bathtubs, showers, sinks, and


hot tubs for every style and budget. Backyard or bath, the Jacuzzi
name stands for beauty, versatility, and excellence.

Cygnet Pool Pumps with A.O. Smith Motor


gpm
Suction Discharge
Model hp at 40 ft
(in.) (in.)
head
7 CYG ¾ 40 2 2
1 CYG 1 61 2 2
15CYG 1½ 75 2 2
2 CYG 2 95 2 2

Jacuzzi Magnum Force Series


gpm Suction Discharge
Model hp at 40 ft (in.) (in.)
head Unions Included
3 MF 3 140 2 2
3 MF3 3 170 3 3
5 MF3 5 220 3 3

28
Pool Filters
Sta-Rite Rugged ABS Thermoplastic Pool/ Spa Cartridge Filter
Inlet/
Filter Area Diameter Height
Model Ideal gpm Outlet/
(Sq. Ft.) (in.) (in.)
Drain (in.)
PXC75 75 38-56 2 12 31 ½
PXC100 100 48-71 2 12 31 ½
PXC125 125 63-94 2 14 42
PXC150 150 75-112 2 14 42
PRC75 75 75 2 10 28 8/9

Sta-Rite Cristal Flow Sand Filters / PWT


Filter Sand Inlet/
Diameter Height
Model Area Max GPM Max GPM Required Outlet/
(Residential) (Commercial) (in.) (in.)
(Sq. Ft.) (kg) Drain (in.)
T-150BP-1 1.2 30 24 45 1½ 15 ¾ 34
T-170BP-1 1.8 45 36 68 1½ 17 ¾ 36 ½
T-200BP-1 2.2 55 44 91 1½ 20 ¾ 38 ½
T-240BP-1 3.1 77.5 62 136 1 ½ 24 ¾ 42
T-300BP-2 4.9 122.5 98 273 2 31 51 ¼
PWT900SB2 6.78 149 120 400 2 36 47
PWT900SB2 - ½ 6.78 169 140 400 2½ 36 44
PWT1070SB2 - ½ 9.57 239 196 600 2½ 42 54
* Commercial Flow Rate – 20 GPM / Sq Ft NSF Listed
** Residential Flow Rate – 25 GPM / Sq Ft max filtration rate, non-NSF listed

Sta-Rite Modular D.E. Filter


Inlet/
Filter Area DE Required Diameter Height
Model Ideal gpm Outlet/
(Sq. Ft.) (kg.) (in.) (in.)
Drain (in.)
PLDE36 36 36-72 2.45 2 18 ½ 36
PLDE48 48 48-96 3.27 2 18 ½ 45 ¼
PRDE55 55 55 1 1½ 10 29
S7MD60 60 96-120 4.09 2 28 ½ 42
S7MD72 72 120-144 5 2 28 ½ 42

J et-Flo Sand Filters


Tank Inlet / Rated Flow Pressure
Sand Height Diameter
Model Diameter Outlet Speed
(in.) (in.) (gpm)
(kg) (kg/ cm2) (in.) (in.)
J F-001-500 19.7 1½ 42 120 2.5 31.9 21.7
J F-002-600 23.6 1½ 62 200 2.5 35.1 23.4
J F-003-750 29.5 2 97 300 2.5 39.6 25.3
J F-004-900 35.4 2 132 400 2.5 48.3 30.7
J F-005-1000 39.4 2 168 550 2.5 48.5 31
J F-006-1200 47.2 2 190 750 2.5 56.4 35.5

29
Jet-Flo Water
Jet-Flo Pool and Spa Accessories:
Products

Vacuum Hose Vacuum Head Telescopic Leaf Scoop Leaf Rake


Handle

Test Kit Dry Acid Corner Brush Pool Brush Algae Brush

Algicide Chlorine DE Powder Zeolite Silica Sand

LED LED Underwater Underwater Fountain Lights


Underwater Underwater Lights Lights
Lights Lights

Spa Light Main Drain Deck Box Frame and Skimmer


Grate Cover

Floating Eyeball Fitting Slotted Eyeball Suction Fitting Flush Plug


Chlorinator

Hose Cuff Hose Adaptor Tile Grating 3 Step Ladder Grab Rail
30
Jet-Flo Water
Products

Air Nozzle Air Regulator Air Regulator Air Button Bath Drain

Spa Jet Spa Jet Straight Spa Spa Jet T-Type Union
Chrome Jet

Tee PVC Y PVC Manifold Blower Laminar


Fountain

Bell Nozzle Foam Nozzle Fan Nozzle Fountain CCQB Nozzle


Nozzle

Chlorine Generator Steamer Wave Ball

Dry Sauna Chemical / Dousing Pump Pool Shark

31
Pool
Heaters Sta-Rite Max-E-Therm LPG Fired Pool / Spa Heater
Recovery Inlet/ Outlet Height Diameter Approx.
Model
(Btu/ hr) (in.) (in.) (in.) Weight (lbs)
SRP200 200,000 2 30.03 32 119
SRP333 333,000 2 30.03 32 122
SRP400 400,000 2 30.03 32 125
 Lightweight ● Rustproof housing: sleek, matte

 Power vented to 25 ft. black enclosure made of


(horizontal) Duraglas
 Compact design ● Low operating cost: 84%
 Environmentally friendly: low NOx efficiency rating
J et-Flo In-Line Electric Pool / Spa Heater
Recovery Connection Height
Model kW Rating Length (in.)
(Btu/ hr) (in.) (in.)
J FSH 12 40,956 12 1.5 9½ 17
 Two (2) dry firing resistant Incoloy electric elements rated 6 kW
240V 60 Hz, single phase
 0 – 50° C dial adjustment temperature setting

 Heavy duty magnetic contactors

 Pressure switch activated at 5 psi to prevent dry firing operation

TPEE Solar Panel


Product Specifications 4m-LDPE
Area 2.72 sq.m.
Size 4m x 68cm
Max Output Temperature +45-60°C
Material Low Density Polyethylene

 Suitable for pre-heating water


 Non-corrosive, chlorine and salt resistant, rollable and ea
install
 No heat exchanger needed

Fireflux Heat Pump Pool Heater


Product Specifications FFP-10
Outlet Water Rated Temp (°C) 60
Heating Capacity 150,000 BTU
Rated Power Input (kW) 9.2
Power Supply (V / Ph / Hz) 230 / 1(3) / 60
Heat Exchanger Titanium
Compressor Type Sanyo / Copeland Scroll (USA)
Compressor Quantity 2 (4)
Cabinet Material 304 Stainless Steel Plate
Alco Thermal Expansion Valve
Refrigerant Flow Restriction (USA)
Refrigerant Type R-22A / R-417A
Pipe Size (inches) 1 1/4”
Dimensions: L x W x H (mm) 1500 x 745 x 1085
Ambient Air Range -20°C to 45°C
Air Discharge Direction Top
Weight (kg) 280
32
Jet Pump
Aermotor Pumps, Inc., a subgroup of Pentair, the largest and most
trusted partner in water systems, manufactures a full line of water
pumps and pump accessories for a variety of applications in the
potable water market, agriculture and irrigation markets, sump
drainage, sewage and effluent markets, and the industrial,
commercial and mining markets. Aermotor exports to over 20
countries around the world.
Domestic Shallow Well and Deep Well Water Pumps

HNA Convertible Jet Pump FH Series Shallow Well Jet Pump

HNA Shallow Well J et Pump FH Series


J et Pumping Depth to Water in Feet Performance
Model hp
Package psi 5 10 15 20 25
20 24.2 23.2 20.2 17.7 12.5
HNA100 12SD 1 30 24 23 20 17.7 12.5
40 16.7 16 13.9 16 10.3
Shut off – psi 61 59 57 54 52
20 14.5 13.9 12.1 10.3 7.9
30 14.4 13.8 12 10.2 7.8
HNA150 CK1 1 40 13.7 13.1 11.4 9.7 7.4
50 12.6 12.1 10.5 8.9 6.8
60 6 5.8 5 4.3 3.3
Shut off – psi 71 69 67 65 63
20 26.8 24.6 21.4 18.2 13.9
30 26.5 24.4 21.2 18 13.8
HNA150 12SD 1½
40 22.9 21 18.3 15.6 11.9
50 15.1 13.9 12.1 10.3 7.9
Shut off – psi 61 59 57 55 53
20 21.6 19.9 17.3 14.7 11.2
30 21.5 19.8 17.2 14.6 11.2
HNA150 CK2 1½ 40 21.3 19.6 17 14.5 11.1
50 16.8 15.4 13.4 11.4 8.7
60 4 3.7 3.2 2.7 2.1
Shut off – psi 71 69 67 65 63

HNA Deep Well J et Pump


Pumping Depth in Feet J et at
Pump J et
Performance hp Venturi Nozzle Max
100

110

120

Model No.
30
20

40

50

60

70

80

90

Depth

Pump Performance in HNA-100 1 10AP J 32P-24 J 34P-44 10.5 10 8.1 6.2 79


Gallons Per Minute - 1 54AP J 32P-22 J 34P-44 6 5.3 4.8 4.2 4.1 3.7 3.5 2.8 2.1 1.6 53
deep well 2" Single 1 ½ 9AP J 32P-29 J 34P-44 11.7 11.1 9.8 6.8 57
Pipe HNA-150
1 ½ 8AP J 32P-18 J 34P-42 6.7 5.8 5.3 4.7 4.5 4.1 3.8 3.1 2.6 2 1.6 72

33
Deep Well Jet
Pumps
VNA2 / MSF Vertical Deep Well
Pumps
The VNA2 Series Vertical Jet Pumps are the industry standard deep
well jet pumps for over-the-well “bolt-on” installations. The VNA2
Series Jet Pumps include the pre-plumbed Aermotor external
automatic regulator, pressure gauge, pressure switch, and a
complete line of casing adapters to drive the 4" double pipe or 2" and
3" single pipe jet packages.
● Automatic Pressure Regulator - Faster-acting and quieter, design
eliminates " hunting" for correct drive pressure
● Quality Construction - Precision-machined, close-grained cast iron

pump body and base are specially treated to resist corrosion


● Noryl® Impeller - Precision-molded for perfect balance, and ultra-

smooth for highest performance and efficiency


● Ideal for water systems and sprinkling applications for your home,

farm or cottage

VNA2 Vertical Deep Well Pumps


Pump Performance
Pump
Model
Deep well (40 psi) 4" double pipe Deep well (40 psi) 2" single pipe Deep well (40 psi) 3" single pipe
VNA2-100 VNA2-150 VNA2-200 VNA2-100 VNA2-150 VNA2-200 VNA2-100 VNA2-150 VNA2-200
HP 1 1 1½ 1½ 2 2 1 1 1.5 1.5 2 2 1 1 1.5 1.5 1.5 2 2 2
Suction 1¼ 1¼ 1¼ 1¼ 1¼ 1¼ 1¼ 1¼ 1¼ 1¼ 1¼ 1¼ 1¼ 1¼ 1¼ 1¼ 1¼ 1¼ 1¼ 1¼
Discharge 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
J et No. 23SD 15SD 23SD 15SD 23SD 15SD 12AP 8AP 12AP 8AP 12AP 8AP 23CP 16CP 23CP 22CP 16CP 23CP 22CP 16CP
Venturi J32P-24 J32P-18 J32P-24 J32P-18 J32P-24 J32P-18 J32P-24 J32P-18 J32P-24 J32P-18 J32P-24 J32P-18 J32P-24 J32P-18 J32P-24 J32P-20 J32P-18 J32P-24 J32P-20 J32P-18

Nozzle J34P-42 J34P-42 J34P-42 J34P-42 J34P-42 J34P-42 J34P-42 J34P-42 J34P-42 J34P-42 J34P-42 J34P-42 J34P-42 J34P-42 J34P-42 J34P-42 J34P-42 J34P-42 J34P-42 J34P-42

30 12.1 5.5 12.2 5.5 12.2 5.5 12.1 5.5 12.2 5.5 12.2 5.5 12.1 5.5 12.2 7.7 5.5 12.2 7.7 5.5
40 11.7 5.5 12.2 5.5 12.2 5.5 11.3 5.5 12 5.5 12 5.5 11.7 5.5 12.2 7.7 5.5 12.2 7.7 5.5
50 11.6 5.5 12.2 5.5 12.2 5.5 11.2 5.3 12 5.5 12 5.5 11.6 5.5 12.2 7.7 5.5 12.2 7.7 5.5
60 11.1 5.4 12.2 5.5 12.2 5.5 10 5.3 12 5.5 12 5.5 11.1 5.4 12.2 7.5 5.5 12.2 7.5 5.5
70 10.2 5.3 11.7 5.5 11.8 5.5 8.8 5.2 11.5 5.5 11.7 5.5 10.2 5.3 11.7 7.5 5.5 11.8 7.5 5.5
80 9.2 5.3 11.3 5.5 11.3 5.5 7.6 5.1 11.2 5.3 11.2 5.3 9.2 5.3 11.3 7.4 5.5 11.3 7.4 5.5
90 7.8 5.2 10.7 5.3 11.2 5.3 6.5 5 9.7 5.2 11 5.2 7.8 5.2 10.7 7.3 5.3 11.2 7.3 5.3
100 6.4 5.1 9.9 5.3 11.1 5.3 5.6 5 8.3 5.1 10.3 5.2 6.4 5.1 9.9 7.3 5.2 11.1 7.3 5.3
110 5 5.1 9 5.2 11 5.2 3.3 5 6.8 5 8.3 5.1 5 5.1 9 7.2 5.2 11 7.2 5.2
120 4 5 8.3 5.1 10 5.1 1.8 5 5.5 5 7.5 5.1 4 5 8.3 7.2 5.1 10 7.2 5.1
130 3 4.8 7 5.1 8.7 5.1 4.5 4.2 5 6.3 5 3 4.8 7 7 5 8.7 7 5.1
140 4.5 4 5 7 5 4.2 3.3 4.8 5.3 4.8 4.5 4 7 5 7 7 5
180 3.3 1.3 4.8 4 5 2 4.3 4.7 3.3 1.3 4.3 4.9 4 5.3 5
200 2.7 4.7 2 4.8 3.5 4.3 2.7 4 4.7 2 5 4.8
220 2 4.5 4.8 2.7 3.7 2 3.2 4 4 4.7 4.7
240 1.3 4.3 4.5 1.7 3.2 1.3 2.2 3.8 3.8 4 4.5
260 1 4 4.3 2.5 1 3 3 3 4.3
280 3.3 4 2.3 2.3 2.2 4
300 2.7 3.3 1.7 1.7 3.3
320 2.7 2.7
J et- Min
Depth
120 200 164 314 195 314 118 198 162 266 193 312 120 200 164 210 268 195 250 314
J et- Max
Depth
76 97 95 172 110 172 80 126 110 158 139 192 76 97 95 110 132 110 128 172

34
Booster Pumps and
HBP Series 4” Horizontal Booster Pumps centrifugal pumps
The HBP Series Booster Pumps are the most
durable booster pumps available. The Patented
SignaSeal floating impeller design minimizes
thrust loads, allowing for continuous operation
without damage to motor bearings, mechanical
seal or pump hydraulic components.

● Patented Stage System - The proven SignSeal™ staging system utilizes a patented ceramic wear surfac
● Acetal Impellers - Precision-molded for perfect balance, and ultra-smooth for highest performance and
● Precision Molded Diffusers - Superior performance with high resistance to corrosion and abrasion
● Ideal for filtration, pressure washing, boosting pressure and general purpose pumping
● Available in 1/2, 3/4, 1, 1 1/2, 2 and 3 HP models

HBP High Pressure Booster Pumps


Total Head in Feet
Model gpm Stages hp 10 12 15 17 20 22 25 27 30 32 35 37 40 42 45 47 50 52 55 57 60
75
0 5 0 5 0 5 0 5 0 5 0 5 0 5 0 5 0 5 0 5 0
7HBP50 7 9 ½ 9.7 9.1 8.5 7.8 6.9 6.0 4.8 3.5 2.5 1.5
7HBP100 7 16 1 9.9 9.6 9.2 8.7 8.2 7.8 7.3 6.6 5.9 5.2 4.4 3.3 2.2
20HBP100 20 7 1 25.0 23.5 22.0 19.0 16.0 11.0 6.0
20HBP150 20 9 1½ 24.0 23.0 22.0 20.3 18.5 14.3 10.0 5.0
20HBP200 20 11 2 25.0 24.0 23.3 22.5 20.8 19.0 17.0 15.0 12.5 10.0 5.0
30HBP200 30 7 2 40.0 37.5 35.0 32.5 28.5 22.5 6.0

Aermotor CT-35 Centrifugal (Booster/Transfer) Pumps

 The basic reliable centrifugal


booster/transfer pumps
 CT-35 has a heavy duty cast iron
construction
 It delivers up to 140 feet of head with

capacities of 90 gpm
 Easy serviceability with all models
(replaceable wear rings and back
pullout design)
 Ideal for water systems and sprinkling

applications for your home, farm or


industry

35
centrifugal
Aermotor pumps
SPCA & SPCH Self-Priming Centrifugal Pumps

SPCA

SPCH

 Self-priming versions of the CT-35


 Heavy duty construction
 Powerful design

Aermotor DMC 2-Stage Centrifugal Booster Pump

 Rugged Construction –Heavy-duty


closed-grain cast iron pump case
and seal-plate
 Drain Port – Provided for easy
winterization
 Easy Serviceabilty – Normal
wearing parts are easily accessible
for service and replacement,
without disturbing piping
 Heavy-Duty Motors – Designed for

continuous operation. A.O. Smith


motors have ball bearing with
stainless steel shaft

36
Centrifugal Pu
Aermotor SSHM-2 2-Stage Self Priming Centrifugal Pump

 Self Priming Design – once initially


primed, SSHM-2 will automatically re-
prime cycle after cycle
 Cast-Ron Motor Bracket – 1-1/4” NPT

discharge connection
 Cast-Ron Suction Flange – 1-1/2” NPT

suction connection
 Heavy-Duty Motors – Designed for
continuous operation. A.O. Smith motors
have ball bearing with stainless steel
shaft

Aermotor – Berkeley's Type B Centrifugal Pumps

B1 ½ TPL 3 HP & 5 HP

Aermotor - Berkeley's Type B close-


coupled end-suction centrifugal pumps
are ideal for most applications requiring
high performance, easy maintenance
and moderate initial cost. Cast iron
construction with unique back pull-out
design permits access to the impeller
without disturbing the piping.

● NEMA Standard motors : high efficiency, low maintenance and smooth quiet performance
● High quality, self-lubricating mechanical shaft seal with corrosion resistant metal parts provi
maintenance free operation and maximum abrasion resistance without leaking
● Multiple taps supplied for easy priming and draining
37
Centrifugal Pumps
• Enclosed impeller is mechanically balanced to reduce bearing loads and increased life. It
is keyed and locked to motor shaft.
• Volute case is made from thick walled close grained cast iron to handle the stresses of

everyday use.
• Motor bracket is precision machined to assure proper component sealing.

• Replaceable stainlees stell shaft sleeve provides maximum corrosion resistance and

protects shaft from wear.


● Discharge may be rotated to any of four positions for piping convenience.

B1WP 7.5 HP B1 ½ TPM 10 HP & 7.5 HP

B2 ZPLS 15 HP B2 ½ ZPL 25 HP & 20 HP

38
Centrifugal Pumps AND SEWA
Aermotor Vertical Multi-stage Pumps (Advance Order)

 Improved design features o-ring compression seal


for extended durability under extreme operating
conditions.
 High Quality 304 SS and 316 SS construction

 Snap-in-place coupling guards

 TEFC or ODP direct coupled motors

 High-pressure tungsten-carbide seal is standard

 Flanged, victaulic or NPT connections

 Premium internal components

Aermotor Vertical Multi-Stage Pumps


deliver outstanding reliability and
performance in the most demanding
operating environments. A selection of
construction materials (Cast Iron, SS 304,
SS 316) are available to maximize process
dependability, versatility and
performance.

Aermotor EC4 Submersible Sewage Pumps

The EC4 Series pump is a


rugged, submersible cast
iron pump with a non-
clog, semi-open impeller
and solids handling
capability to ¾" Unit has
a 4/10 hp single phase
motor complete with
power cord. 2” NPT
vertical discharge is
standard.

●Bearing and Mechanical Seal - Permanently lubricated


for long life
● Stainless Steel Hardware - Allows easy disassembly

after extended service


● Overload Protection - Built-in thermal overload with

automatic reset
● Cord Seal - Protects motor if cord is damaged; prevents

oil loss from motor


39
Centrifugal Pumps AND SEWAGE PUMPS
Aermotor EH7 Series Submersible Pumps

Our best in effluent


sewage pumps, the EC6/
EC7 /EH7 Series pump is
a rugged, submersible
cast iron pump with a
non-clog, semi-open
impeller and solids
handling capability of up
to ¾". Unit has a ½ or a 1
hp single or three phase
motor complete with
power cord.

● Stainless Steel Hardware - Allows easy


disassembly after extended service
● Overload Protection - Built-in thermal
overload with automatic reset
● Bearing and Mechanical Seal -
Permanently lubricated for long life
● Cord Seal – Protects motor if cord is
damaged; prevents oil loss from motor

Aermotor SC9 Series Submersible Pumps

Our best in
sewage pumps,
the SC9/ SCC9
Series pump is a
rugged, cast iron,
submersible pump
with a non-clog,
two-vane semi-
open impeller and
solids handling
capability of up to
2".
● Impeller - Non-clog two vane semi-open style
● Dual Shaft Seals - Primary mechanical seal
with a secondary self-lubricating lip seal
● Seal Plate Barrier Ring- The seal plate barrier

ring protects the seals from debris


● Solid Handling - 2" spherical solids handling

capabilities

40
SUBMERSIBLE PU
Aermotor Stainless Steel Submersible Pumps

● Discharge - Heavy-duty 300 grade stainless steel construction provides smooth


water passage to column pipe
● Field proven A+, sealed and lubricated top bearing assembly keeps abrasives

out, ensuring long bearing life

S Series
● Cast Stainless Steel Discharge Head - Strong, corrosion resistant and lead free

● Built-in spring-loaded check valve poppet - Positive sealing, field-proven, non-spin de

● Offers heads to 1000 feet and capabilities to 35 GPM

A+ Series
● Cast Stainless Steel Discharge Head - Strong, corrosion resistant and lead free

● External Stainless Steel Check Valve - Spring-loaded, positive sealing non-spin

design valve
● Offers heads to 1000 feet and capabilities to 35 GPM

Stainless Steel Submersible Pump


Depth to Water in Feet Shutoff Head
Model Stages hp
psi 20 30 40 50 60 70 80 90 100 125 150 175 200 225 250 275 300 350 400 Feet psi
0 51 48 46 36 27 17
20 55 52 49 46 43 40 36 32 29 19
30 48 46 42 38 34 32 27 24 19
35-150 7 1½ 205 89
40 41 37 34 31 26 23 19
50 33 29 24 21 19
60 24 19 15
0 53 46 38 32 23 15
20 51 48 45 42 39 32 25 16
30 53 51 42 44 41 38 36 32 26 17
35-200 9 2 40 50 46 44 41 38 34 32 28 26 18 265 115
50 42 40 37 33 31 28 25 22 18
60 36 32 30 26 24 20 17
70 29 26 23 20 16
0 53 48 43 38 34 28 23 17
20 52 50 48 44 39 34 29 24 18
30 52 50 48 46 44 40 35 30 24 20
35-300 12 3 40 51 47 45 44 42 40 35 30 24 20 350 152
50 51 49 47 45 43 41 40 37 36 31 25 20
60 46 44 42 41 39 37 34 32 31 26 20
70 42 40 38 36 34 32 30 28 26 24 14
0 66 62 58 54 49 38
20 64 59 55 51 46 42 36 32
30 54 50 44 40 35 30
50-200 6 2 40 44 49 35 39 180 78
50 34 29
60 30
70
0 67 59 51 43 35 25
20 65 62 59 55 52 44 36 26
30 67 64 60 58 54 50 48 44 40 27
50-300 9 3 40 64 60 56 53 50 46 44 40 38 28 280 121
50 56 51 49 46 42 39 36 33 29
60 48 44 41 38 34 30 27
70 40 38 34 30 26
0 66 61 55 51 46 41 30
20 61 62 56 52 47 42 36 30
30 66 62 57 52 47 43 37 31 24
50-500 15 5 40 66 64 62 58 52 47 42 37 31 25 440 190
50 66 63 61 60 57 53 48 43 37 32 25
60 65 63 61 59 57 55 53 48 43 38 32 26
70 68 62 60 58 56 54 52 51 48 44 38 33 26 20
0 115 103 86 72 56
20 122 117 112 107 102 95 88 81 74 59
30 119 115 111 106 101 94 87 80 73 58
90-500 12 5 40 108 103 98 91 84 78 72 65 57 258 112
50 96 90 83 77 71 64 56
60 82 76 70 63 55

41
Pressure Tanks
Global Water Solutions offers the SuperFlow Series, a very
wide range of interchangeable diaphragm pressure vessels
that makes GWS one of the most comprehensive suppliers
globally.

As with all GWS products, SuperFlow vessels are


manufactured to strict quality standards.

SuperFlow offers an interchangeable membrane which


features a unique tiered design that is more durable. All
SuperFlow Models 100 liters and above are designed with a
built-in pressure gauge, a convenience feature at no extra
cost.

SuperFlow vessels represent the best value for your


investment with rugged construction and are designed to
serve your need for years to come.

● Built-in pressure gauge


(Models SF100-SF10,000)

●Interchangeable / Repairable /
Replaceable membrane with
unique tiered design

● 10 bars maximum
operating pressure
(optional 16 and 25 bars
maximum rating)
● ISO:9001, GOST, CE Approved

SuperFlow Stock Models


Diameter (A) Height (B) Pre-Charge Connection Volume Ship Weight
Model Type
cm inches cm inches bar inches liters gallons kg lbs
SF2410V-IL In Line 26 10.2 44.5 17.5 1.5 1 24 6 5 11
SF10010V Vertical 46 18.1 93.5 36.8 3 1 100 26 24 52.9
SF30010V Vertical 64 25.2 121 47.6 4 1¼ 300 79 55 121
SF50010V Vertical 75 29.5 152 59.8 4 1¼ 500 132 97 214
SF85010V Vertical 80 31.5 192 75.6 4 2 850 224 165 364
SF150010V Vertical 96 37.8 240 94.5 4 2 1500 396 251 553
SF200010V Vertical 110 43.3 250 98.4 4 2 2000 528 371 818
SF2410H Horizontal 44.5 17.5 33 13 1.5 1 24 6 5.5 12.1
*Bigger models up to 10,000 liters may be ordered and fabricated

42
Pressure Tan
Tank Selection
When using large standard galvanized tanks, a constant air cushion is required for proper operation of the water
System. The illustrations show the percent of tank volume as related to the pressure gauge reading. To determine
The amount of water you will receive as drawoff from the tank,you should subtract the smaller number from the
larger number to get the percentage. Then multiply by the size of the tank to get the gallons drawoff.

Example:
50Lbs = 77.3
Minus 30 lbs = 67.2
= 10.1%
Multiply x 120 gallon size (size of tank)
= 12.12 gallons drawoff

Additional Pressure Gauge


Access Opening (Available on all
SF100V-
10,000V
Brass Air Valve models)
Butyl/EPDM
Tiered
Long-Lasting Membrane
Polyurethane Paint

Reinforced
Heavy-Duty
Tripod Legs
Corrosion-Resistant
Flange Connection

43
Water heating operating costs
Operating Cost Comparison of Electric, LPG/ Gas, Cyclone Heaters and Heat Pump Water Heaters
Cost Comparison Per 1000 Gallons of Hot Water at 70 °F Temperature Rise

Water Standard CYCLONE CYCLONE Heat


Electric
Operating Water Operating (BTH-120 Operating (BTH-300 Operating Diesel Operating Pump Operating
Heater Water
Cost Gas Cost & Cost & Cost Burner Cost Water Cost
Type Heater
Heater BTH-199) BTH-400) Hater

BTU REQUIREMENT: 577,500 Btu


Primary
Electricity LPG LPG LPG Diesel Electric
Source
Efficiency 100% 80% 94% 99% 80% 400%
Cost / Cost / Cost / Cost / Cost / Cost / Cost / Cost / Cost/ L Cost / Cost / Cost /
Cost at Different Types of Primary Heat

kWh 1000 gal kg LPG 1000 gal kg LPG 1000 gal kg LPG 1000 gal Diesel 1000 gal kWh 1000 gal
4 Php677 32 Php513 32 Php437 32 Php415 28 Php535 4 Php169
4.5 Php761 33 Php529 33 Php451 33 Php428 29 Php552 4.5 Php190
5 Php846 34 Php545 34 Php464 34 Php441 30 Php569 5 Php212
5.5 Php931 35 Php561 35 Php478 35 Php454 31 Php586 5.5 Php233
6 Php1,015 36 Php578 36 Php491 36 Php467 32 Php602 6 Php254
6.5 Php1,100 37 Php594 37 Php505 37 Php480 33 Php619 6.5 Php275
Source

7 Php1,184 38 Php610 38 Php519 38 Php493 34 Php636 7 Php296


7.5 Php1,269 39 Php626 39 Php532 39 Php506 35 Php652 7.5 Php317
8 Php1,354 40 Php642 40 Php546 40 Php519 36 Php669 8 Php338
8.5 Php1,438 41 Php658 41 Php560 41 Php531 37 Php686 8.5 Php360
9 Php1,523 42 Php674 42 Php573 42 Php544 38 Php703 9 Php381
9.5 Php1,607 43 Php690 43 Php587 43 Php557 39 Php719 9.5 Php402
10 Php1,692 44 Php706 44 Php601 44 Php570 40 Php736 10 Php423
10.5 Php1,777 45 Php722 45 Php614 45 Php583 41 Php753 10.5 Php444
11 Php1,861 46 Php738 46 Php628 46 Php596 42 Php770 11 Php465
*Rates based on Metro Manila prices as of December 2009.

Recovery Capacities– Electric Recovery Capacities – LPG


Element gph recovery at indicated temperature rise Input Rating gph recovery at indicated temperature rise
Wattage 60 °F 70 °F 80 °F 90 °F 100 °F Btuh 60 °F 70 °F 80 °F 90 °F 100 °F
750 5.2 4.4 3.9 3.4 3.1 30,000 45.5 39.0 34.1 30.3 27.3
1,000 6.9 5.9 5.2 4.6 4.1 33,000 50.0 42.9 37.5 33.3 30.0
1,250 8.6 7.4 6.5 5.7 5.2 35,000 53.0 45.5 39.8 35.4 31.8
1,500 10.3 8.9 7.8 6.9 6.2 40,000 60.6 51.9 45.5 40.4 36.4
2,000 13.8 11.8 10.3 9.2 8.3 43,000 65.2 55.8 48.9 43.4 39.1
2,250 15.5 13.3 11.6 10.3 9.3 50,000 75.8 64.9 56.8 50.5 45.5
2,500 17.2 14.8 12.9 11.5 10.3 60,000 90.9 77.9 68.2 60.6 54.5
3,000 20.7 17.7 15.5 13.8 12.4 70,000 106.1 90.9 79.5 70.7 63.6
3,500 24.1 20.7 18.1 16.1 14.5 80,000 121.2 103.9 90.9 80.8 72.7
4,000 27.6 23.6 20.7 18.4 16.5 90,000 136.4 116.9 102.3 90.9 81.8
4,500 31.0 26.6 23.3 20.7 18.6 100,000 151.5 129.9 113.6 101.0 90.9
5,000 34.5 29.5 25.9 23.0 20.7
5,500 37.9 32.5 28.4 25.3 22.8

Projected Operating Cost Calculation Per Year

_______ Gallons of Hot Water Used Per Year at 70 °F rise / 1,000


X _______ Cost per 1000 Gallons (See Table above – use most realistic utility
costs)
= _______ Projected Operating Cost Per Year

44
Water Heater
Sizing Tables Based on Collected Data and ASHRAE Requirements Sizing
Dormitories
Gals Required 2 Hour Period 140 °F Water Gals Required 2 Hour Period 140 °F Water Minimum
Number of 3 gpm 5 gpm Storage
Persons Capacity
40 °F Inlet 100 °F TR 60 °F Inlet 80 °F TR 40 °F Inlet 100 °F TR 60 °F Inlet 80 °F TR (US Gal.)
1 – 10 125 100 200 160 100
11 – 15 187 150 299 239 150
16 – 20 250 200 400 320 200
21 – 25 277 220 443 354 225
26 – 30 300 240 480 384 240
31 – 40 320 264 512 410 280
41 – 50 350 280 560 448 310
51 – 75 412 330 659 527 400
76 – 100 500 400 800 640 430
101 – 125 625 500 1000 800 475
126 – 150 750 600 1200 960 510
151 – 175 875 700 1400 1120 560
176 – 200 1000 800 1600 1280 600
201 – 250 1250 1000 2000 1600 650
251 – 300 1500 1200 2400 1920 720
301 – 350 1750 1400 2800 2240 800

Hotels
Gals Required 2 Hour Period 140 °F Water
Number of Units Actual Number Minimum Storage
40 °F Inlet 100 °F
(1 ½ Persons/ Unit) of Persons 60 °F Inlet 80 °F TR Capacity (US Gal.)
TR
1– 3 4 50 45 50
4 6 66 56 60
5– 6 9 100 85 72
7– 8 12 132 112 85
9 – 10 15 165 140 100
11 – 15 22 230 196 113
16 – 20 30 300 255 130
21 – 25 37 370 315 148
26 – 30 45 450 382 162
31 – 35 52 520 442 175
36 – 40 60 570 485 188
41 – 45 67 600 510 200
46 – 50 75 650 552 210
51 – 75 112 840 714 255
76 – 100 150 1050 892 300
101 – 125 187 1272 1080 325
126 – 150 225 1350 1148 360
151 – 175 262 1575 1340 395
176 – 200 300 1800 1530 410
201 – 250 375 2250 1912 500
251 – 300 450 2700 2295 600
301 – 350 525 3150 2678 700

45
Pool heater sizing and INSTALLATION
Pool Heater Sizing – Area Method
Surface Area Btu/ hr Input at Average Temperature Difference in Degree Fahrenheit – Coldest Month
(sq ft) 10 15 20 25 30 40 50
150 24,000 36,000 48,000 60,000 72,000 96,000 120,000
200 32,000 48,000 64,000 80,000 96,000 128,000 160,000
250 40,000 60,000 80,000 100,000 120,000 160,000 200,000
300 48,000 72,000 96,000 120,000 144,000 192,000 240,000
400 64,000 96,000 128,000 160,000 192,000 256,000 320,000
500 80,000 120,000 160,000 200,000 240,000 320,000 400,000
600 96,000 144,000 192,000 240,000 288,000 384,000 480,000
800 128,000 192,000 256,000 320,000 384,000 512,000 640,000
1,000 160,000 240,000 320,000 400,000 480,000 640,000 800,000
1,250 200,000 300,000 400,000 500,000 600,000 800,000 1,000,000
1,500 240,000 360,000 480,000 600,000 720,000 960,000 1,200,000
1,750 280,000 420,000 560,000 700,000 840,000 1,120,000 1,400,000
2,000 320,000 480,000 640,000 800,000 960,000 1,280,000 1,600,000
2,500 400,000 600,000 800,000 1,000,000 1,200,000 1,600,000 2,000,000
3,000 480,000 720,000 960,000 1,200,000 1,440,000 1,920,000 2,400,000
3,500 560,000 840,000 1,120,000 1,400,000 1,680,000 2,240,000 2,800,000
4,000 640,000 960,000 1,280,000 1,600,000 1,920,000 2,560,000 3,200,000
4,500 720,000 1,080,000 1,440,000 1,800,000 2,160,000 2,880,000 3,600,000
5,000 800,000 1,200,000 1,600,000 2,000,000 2,400,000 3,200,000 4,000,000
6,000 960,000 1,440,000 1,920,000 2,400,000 2,880,000 3,840,000 4,800,000
7,000 1,120,000 1,680,000 2,240,000 2,800,000 3,360,000 4,480,000 5,600,000
8,000 1,280,000 1,920,000 2,560,000 3,200,000 3,840,000 5,120,000 6,400,000

Typical Swimming Pool Layout

46
Pool Chlorine Pool chemical guide / spa
Guide
Directions: For new or newly refilled pools, add 10 oz. of chlorine per
10,000 gallons of pool water. Then run the filtration system for 24 Daily Dosage
hours. Adjust ph to 7.4 - 7.6 and test for chlorine residual. Do not Pool Capacity Unstabilized Stabilized
allow bathers to swim when chlorine residual is above 2.00 PPM. (US Gal) Pool Water Pool Water
Then simply follow the chlorine dosage shown below.
5000 1/8 kg 1/16 kg
Superchlorination: Should pool water appear cloudy or dirty, add 20 10000 1/6 kg 1/12 kg
oz. of chlorine concentrate per 10,000 gallons, allowing the pool filter 15000 ¼ kg 1/8 kg
to run so as to turn the pool water over in the pool. This process 20000 2/5 kg 1/5 kg
should be repeated until the pool water is clear and sparkling. 25000 ½ kg ¼ kg
Normal chlorination is not necessary during this process. Do not 50000 1 kg ½ kg
allow bathers when chlorine residual is over 2.00 PPM.
Raising PH with Soda Ash
(When PH level is under 7.4 – 7.6, add this amount of Soda Ash then retest.)
Gallons in Pool
PH 1,000 5,000 10,000 15,000 20,000 25,000 50,000
7.2 – 7.4 1/24 lbs 1/12 kg 1/6 kg 1/4 kg 1/3 kg 1/2 kg 1 kg
7.0 – 7.2 1/20 lbs 1/8 kg 1/4 kg 1/3 kg 1/2 kg 2/3 kg 1 1/8 kg
6.6 – 7.0 1/12 lbs 1/6 kg 1/3 kg 1/2 kg 2/3 kg 1 kg 2 kg
under 6.7 1/8 lbs 1/4 kg 1/2 kg 2/3 kg 1 kg 1 1/8 kg 2 1/4 kg

Lowering PH with Dry Acid / Sodium Bisulfate


(When PH level is over 7.6, add this amount of Acid then retest.)
Gallons in Pool
PH 1,000 5,000 10,000 15,000 20,000 25,000 50,000
7.6 – 8.0 0.2 oz 1 oz 2 oz 3 oz 4 oz 5 oz 10 oz
Over 8.0 1 – 1.5 oz 2 – 3 oz 4 – 6 oz 6 – 9 oz 8 – 12 oz 10 – 15 oz 12 – 18 oz

Typical Spa
Air
Layout Connection

Underwater Light Water


Connection
Spa Jet
Air Vent

Air Jet Air Vent


Air Switch
Blower Switch

2” Dia

1” Dia 47
Conversion
table Conversion Table
Length Volumetric Flow
1 Millimeter (mm) 0.001 m 1 Cubic Meters Per Second 15850 gpm
1 Centimeter (cm) 10 mm 1 Liter Per Second 15.85 gpm
1 Meter (m) 100 cm 1 Gallons Per Minute, US (gpm) 60 gph
1 Inch (in) 2.54 cm 1 Gallons Per Minute, US (gpm) 1440 gpd
1 Foot (ft) 12 in Water Volume vs Mass
1 Yard (yd) 3 ft 1 Cubic Feet (water) 62.37 lbs
Mass 1 Gallon, US (gal) 8.34 lbs of Water @ 60 deg F
1 Gram (g) 0.035 oz Energy
1 Kilogram (kg) 2.2 lbs 1 J oule (J ) 1 Watt Second (Ws)
1 Kilogram (kg) 1000 g 1 Kilojoule (kJ ) 1000 J
1 Ounce (oz) 28.35 g 1 Watt Hour (wh) 3.6 kJ
1 Pound (lb) 16 oz 1 Watt Hour (wh) 3.415 Btu
1 Pound (lb) 7,000 grains 1 Calorie (cal) 4.187 J
1 Ton 2000 lbs 1 Kilocalorie (kcal) 1.163 wh
Volume 1 British Thermal Unit (Btu) 252 cal
1 Cubic Meter 1000000 m3 1 British Thermal Unit (Btu) 0.293 wh
1 Liter (l) 0.001 m3 1 Kilogram of LPG 45,000 Btu
1 Cubic Inches (cu in) 0.016 l 1 Gallon (US) of Diesel 139,000 Btu
1 Cubic Feet (cu ft) 1728 cu in Power
1 Cubic Feet (cu ft) 7.48 gal 1 Kilowatt (kW) 1.34 hp
1 Gallon, US (gal) 3.79 l 1 Horsepower (hp) 0.746 kW
1 Gallon, US (gal) 231 cu in 1 Ton Refrigeration 12,000 Btu/hr
1 Gallon, Europe (gal) 4.55 l 1 Boiler Horsepower 33,523 Btu/hr
1 Ounce, fluid (fl oz) 0.03 l Pressure
Temperature 1 Pounds per Square Inch (psi) 2.31 feet of water @ 4 deg C
°C to °F (T°C x 9/5) + 32 1 Atmosphere 14.7 psi
°F to °C (T°F - 32) x 5/9 1 Bar 14.5 psi
K to °C T K – 273 1 Bar 100,000 Pascals
Area Formulas Volume Formulas
Square SxS Box SxSxS
Rectangle LxWx H Sphere Side 1 x Side 2 x Side 3
Circle Π x r² Cylinder Π x r² x Height
Triangle ½ (Height x Base) Pyramid 1/3 x Base Area x Height

48
Conversion Tables
Conversion Table
Temperature Volume Power
Kelvin Celsius Fahrenheit Liters Gallons, U S (gal) HP KW BTU/ hr
0 -273 -459.4 10 2.64 1/8 0.09 318.26
273 0 32 20 5.28 1/6 0.12 424.35
310.5 37.5 99.5 30 7.92 0.25 0.19 636.52
373 100 212 40 10.55 0.5 0.37 1,273.05
Celsius Fahrenheit 50 13.19 1 0.75 2,546.10
0 32 60 15.83 1.5 1.12 3,819.15
5 41 70 18.47 2 1.49 5,092.20
10 50 80 21.11 2.5 1.87 6,365.25
15 59 90 23.75 3 2.24 7,638.29
20 68 100 26.39 5 3.73 12,730.49
25 77 120 31.66 7.5 5.6 19,095.74
30 86 Gallons, US (gal) Liters 10 7.46 25,460.98
35 95 2 7.58 15 11.19 38,191.47
40 104 4 15.16 20 14.92 50,921.96
45 113 6 22.74 25 18.65 63,652.45
50 122 8 30.32 KW BTU/ hr HP
55 131 10 37.9 1 3,413 1.34
60 140 12 45.48 1.5 5,120 2.01
65 149 15 56.85 2 6,826 2.68
70 158 20 75.8 2.5 8,533 3.35
75 167 30 113.7 3 10,239 4.02
80 176 40 151.6 3.8 12,969 5.09
85 185 50 189.5 4 13,652 5.36
90 194 60 227.4 4.5 15,359 6.03
95 203 75 284.25 5.5 18,772 7.37
100 212 80 303.2 6 20,478 8.04
Fahrenheit Celsius 90 341.1 6.5 22,185 8.71
20 -6.67 100 379 7.5 25,598 10.05
30 -1.11 120 454.8 9 30,717 12.06
40 4.44 Pressure 11 37,543 14.74
50 10 PSI Bar ft. of Water 12 40,956 16.08
60 15.56 14.5 1 33.5 18 61,434 24.12
70 21.11 20 1.38 46.2 36 122,868 48.24
80 26.67 30 2.07 69.3 54 184,302 72.36
90 32.22 40 2.76 92.4 BTU/ hr KW HP
100 37.78 50 3.45 115.5 36,000 10.55 14.13
110 43.33 60 4.14 138.6 66,700 19.54 26.19
120 48.89 70 4.83 161.7 75,100 22 29.49
130 54.44 80 5.52 184.8 120,000 35.16 47.11
140 60 90 6.21 207.9 180,000 52.74 70.67
150 65.56 100 6.9 231 199,000 58.31 78.13
160 71.11 110 7.59 254.1 280,000 82.04 109.93
170 76.67 120 8.28 277.2 300,000 87.9 117.78
180 82.22 130 8.97 300.3 400,000 117.2 157.05
190 87.78 140 9.66 323.4 500,000 146.5 196.31
200 93.33 150 10.34 346.5 750,000 219.75 294.46

49
PE FRICTION

3”

50
PIPe friction

51
About Us
Amici Mercantile Inc. started out in 1976 as a retailer of various water systems in Angeles City,
Pampanga. Providing customers with only top quality products, Amici has earned the reputation in
Pampanga as the trusted partner in water systems.

In 1997, to provide its customer base with a broader range of quality products at better prices, Amici
started importing and distributing select water system products in the Philippines.

Now handling key brands in the global market such as A.O. Smith, Aermotor, Atmor and Sta-Rite, Amici
seeks to reach more households through better distribution while giving ample support in terms of
information and technical knowledge learned with experience and training.

Heaters MANILA
Shower / Multipoint Instantaneous Heaters. Electric / Amici Mercantle Inc.
LPG / Diesel Storage Water Heaters. Hot Water Boilers.
Storage Tanks. Hot and Cold Circulating. Pumps. Heat Office: 86 Mayon St. corner M. Cuenco St.,
Pumps. Solar Heating. Templifier. Preventive Sta. Mesa Heights, Quezon City
Maintenance.
Phone: 740-6675 740-6676 448-5788
416-4470 416-5171
Pumps
Shallow Well. Deep Well. Submersible. Booster. Sewage. Fax: 740-6677
Centrifugal. Transfer.
Email: info@amici.com.ph
Tanks
Hot Water Storage. Expansion. Diaphragm.
CEBU
Amici Water Systems Sales and Services
Pool, Spa and Liesure Office: Doors 111-112 MGA Arcade,
Pool and Spa Heater. Pumps. Sand and DE Filters. A. C. Cortes, Mandaue City, Cebu
Heaters. Chlorinators. Skimmer. Drain. Vacuum.
Chemicals. Lighting. Wave Generators. Fountains. Air Phone: 032-420-4042 032-344-5400
Blowers. Spa Jets. Sauna and Steamers. Fittings. 032-344-6400
Accessories.
Fax: 032-344-5400

Email: cebu@amici.com.ph

PAMPANGA
Aiho Enterprise

Office: 1348 Miranda Extension,


Angeles City, Pampanga

Phone: 045-887-1764 045-322-1996

Fax: 045-887-1764

Email: aiho@amici.com.ph

www.amici.com.ph