GENERAL NOTES / LEGEND

1.1 This set of drawings is to be read in conjunction with the


BENDING/BUIGING

TOTAL NO BARS
architectural, mechanical and electrical drawings

TOTALE AANTAL
BARS/MEMBER
AANTAL DELE
(unless they do not occur), and any discrepancies between

STAWE/DEEL
8Y10-SA-250 Stir them shall be reported to the Engineer immediately.

MEMBER

NO OFF

LENGTH
LENGTE
A B C D E/r

MARK
MERK

CODE
KODE
1.2 No scaling of dimensions is permitted on these drawings.

DEEL

DIAM
100mm thick

DIA
concrete slab with Only written dimensions which, unless otherwise stated, are
mesh ref 193 given in millimetres, may be deemed to be correct. If any
TOS Level: 1 4 4 08 34 Y20 6450 6300 dimension seems doubtful, the Engineer should be consulted.

RC Ground Beam
300 x 600mm Deep
24.27
Top of Paving 4 4 09 35 Y20 6200 5930
2Y20-11 T 21 1.3 All existing dimensions and levels are to be checked on site
2Y20-11 B Y1 Level: 4 4 10 34 Y20 5450 5300

100
and verified. Any discrepancies or variations from the drawings
0-

50
24.10 4 4 11 34 Y20 2250 2100
SA shall be reported immediately.No work shall commence nor any
- 4 4 12 62 Y20 2000 1000 634 (1000) material be ordered until the Engineer is notified accordingly.
2Y20-12 T 25
0 4 4 13 20 Y20 5150 (5170)
2Y20-12 B St
ir r 1.4 All work is to comply with the most recent revisions of the
ip 4 4 14 62 Y20 2000 1000 775 (1000)
19Y10-SA-200 Stirrups

2Y20-13 T s National Building Regulations (NBR) and the latest editions


Selected backfill material 4 4 15 20 Y20 2950 (2940)
2Y20-13 B of the relevant SABS codes of practice and standard methods.
compacted to 98% mod aashto
4 4 16 34 Y20 5650 5500
150 selected fill density in layers not
Stripfooting 4 4 17 34 Y20 6550 6380 1.5 All building materials are to comply with the latest editions of
material compacted exceeding 150mm in thickness
Reinforcement 4 4 18 35 Y20 2750 2470 the relevant SABS specifications.
to 95% mod. Aashto
density 4 4 19 35 Y20 5750 5450
1.6 These designs and/or drawings are not sold, and are subject to
4 4 20 34 Y20 3050 2920
300x600mm recall. Reproduction or copying rights are reserved solely to
RC Ground Beam 32 32 21 34 Y20 4400 4260 Gecor (Pty) Ltd under copyright law. These drawings have been
2Y20-10 T 2Y20-14 T 8 8 22 34 Y20 5350 5220 delivered and received on the following express conditions:
2Y20-10 B 2Y20-14 B TOF Level: 4 4 23 35 Y20 5050 4770

6Y10-SA-250
23.07 8 8 24 20 Y20 5650 (5670) (a) they are not to be used in any way which may be
28 28 28 28 28 construed as being against the interests and/or benefits
1000 x 300d RC 8 8 25 20 Y20 5650 5670
2Y20-15 T of Gecor (Pty) Ltd;
Stripfooting 8 8 26 34 Y20 3650 3520
2Y20-15 B (b) they and all copies shall be returned to Gecor (Pty) Ltd

300
R10-SC-250 6 6 27 20 Y12 3100 3120
22Y10-SA-250 Stirrups immediately on demand;
10 10 28 20 Y12 3750 3770

28 28 28. 28 28 6 6 29 20 Y12 4750 4750 (c) all information disclosed by these drawings shall be deemed
2Y20-18 T to be confidential and treated as such.

85

35
350 300 230
2Y20-18 B 248 248 SA 60 Y10 1550 500 200
2Y20-09 T 28 28 SB 60 R10 1550 500 130
2Y20-09 B 13 13 SC 60 R10 1550 900 180

SECTION A-A FOUNDATION NOTES


9Y10-SA-250 Stir Scale 1:20 1. Foundation excavations are to be approved in writing by the
23Y10-SA-250 Stirrups

STEEL WEIGHT (Kg) Total engineer prior to casting.


8 10 12 16 20 25 32 (Kg)
2. A 50mm thick class 15/38 blinding layer is to be cast under
R 43 43 the full extent of all reinforced concrete bases.
2Y20-08 T 2Y20-16 T 2Y20-19 T
2Y20-08 B 2Y20-16 B 2Y20-19 B Y 237 75 1352 1664
3. Backfilling shall be done with approved material placed in layers
TOT
21Y10-SA-250 Stirrups

21Y10-SA-250 Stirrups
237 75 1352 1707 having a maximum depth of 150mm before compaction and each
layer shall be compacted to 95% mod. Aashtodensity or as
10mm jointex or similar directed bythe engineer.
dpm (see arch. Details)
100mm thick 4. Manual compaction of soil is to take place only within 50mm
concrete slab with of walls.
mesh ref 193
5. Poor founding material below foundations shall be removed to the
depth ordered bythe engineer and backfilled with mass concrete
of class 15/38.

CLIENT PLAN NUMBER

218024
2Y20-20 T
2Y20-20 B
2Y20-17 T REFERENCE DRAWINGS
2Y20-17 B
NUMBER REVISION DRAWING DESCRIPTION
Selected backfill material Selected backfill material
compacted to 98% mod aashto compacted to 98% mod aashto
density in layers not
27 27 27 Y20 Y20
density in layers not
-- -- --
exceeding 150mm in thickness exceeding 150mm in thickness
23Y10-SA-200 Stirrups 9Y10-SA-250 Stir
APPROVED BY COUNCIL / CLIENT
300 x 600mm Deep
Reinforced Concrete
27 27 27
Ground Beam

Class 30MPa/19 CITY ENGINEER / CLIENT REG. NO. DATE


SECTION B-B
Scale 1:20 AMENDMENTS CODE

A,B,C.../ : BEFORE TENDER /A : BY CLIENT


0 / : TENDER DRAWING /B : BY ARCHITECT
1,2,3.../ : AFTER TENDER /C : BY MECHANICAL OR ELECTRICAL
Y10-SA-250
Z / : AS BUILT /D : BY GECOR
11R10-SB-250 Stir

3Y12-27-250 T /E : BY OTHER ( )
3Y12-27-250 B
DATE INITIAL No./CODE REVISION DESCRIPTION
Y20 Y20
3Y12-29-250 B
3Y12-29-250 T

07.08.2019 RN A/B For Construction

B Reinforced Concrete Pad

OFFICES
PROVINCE OFFICE E-MAIL

Eastern Cape Port Elizabeth (041) 922-4283 ricardo@gecor.co.za

17R10-SB-250 Stir Visit or contact us online at www.gecor.co.za

18Y10-SA-250 Stir 18Y10-SA-250 Stir 18Y10-SA-250 Stir 13Y10-SA-250 Stir


TYPICAL SECTION THRU GROUND BEAM
Scale 1:10
GECOR (Pty) Ltd
Engineers | Architects | Project Managers|
REINFORCEMENT:
Civil, Structural & Electrical Engineers. Environmental & Project Management
12Y10-SA-250 Stir

12Y10-SA-250 Stir

1. Yield strength of reinforcing shall be as follows


Mild steel (R) 250 MPa CLIENT

1000 x 300mm Deep Reinforced Concrete Footing for Retaining wall


2Y20-21 T 2Y20-22 T 2Y20-21 T 2Y20-24 T 2Y20-21 T 2Y20-25 T 2Y20-21 T 2Y20-26 T
High tensile steel (Y) 450 MPa
2Y20-21 B 2Y20-22 B 2Y20-21 B 2Y20-24 B 2Y20-21 B 2Y20-25 B 2Y20-21 B 2Y20-26 B
Mesh 485 MPa
2. Symbols denoting layers of reinforcement in slabs: Mrs D M Bussy
3. Cover to reinforcement shall be as follows unless otherwise indicated
PROJECT
Foundations and ground beams:
* bottom and sides: 75mm
* top: 50mm
Retaining walls: 40mm

Unreinforced Concrete
House Bussy
28Y10-SA-250 Stir

28Y10-SA-250 Stir

Other structures under ground: 40mm


Mesh in surface beds > 100: 50mm from top
2Y20-23 T Pad BB Mesh in surface beds < in middle of surface bed Proposed New Dwelling
2Y20-23 B Columns: 40mm to main rebar:30mm stirrups
R.C. Walls: 30mm on Portion 778 (195)
Suspended slabs: 30mm
Suspended beams: 30 to stirrups of Lot 61 No. 15221
Stairs:
Water retaining structure: 30mm Salt Rock, Dolphin Coast
17Y10-SA-250 Stir

17Y10-SA-250 Stir

Piles: 75mm
Concrete cover shall be within the following tolerances: +5mm/-0mm
4. Lap/splice lengths to be provided as follows:
Structures other than liquid retaining structures : 50 x smaller diameter
5Y12-28-250 T DRAWING TITLE
Lliquid retaining structures : 55 x smaller diameter
5Y12-28-250 B
Mesh
5. Where possible reinforcing laps/splices should be staggered
2Y20-21 T 2Y20-21 T 2Y20-24 T 2Y20-21 T 2Y20-25 T 2Y20-21 T 2Y20-26 T 6. Welding and flame cutting/heating of reinforcement are not allowed Ground Beams and Foundation
2Y20-21 B 2Y20-21 B 2Y20-24 B 2Y20-21 B 2Y20-25 B 2Y20-21 B 2Y20-26 B 7. Pull-out bars for liquid retaining structures shall not be permitted
8. Reinforcement must be clean of all dirt, grease, oil, scale, loose rust or other deleterious material Reinforcement
9. No concrete shall be cast until the reinforcement has been inspected and approved in writing by the engineer.
2Y20-22 T
A
Reinforcement shall be inspected only after it has been completely fixed in position, formwork is clean, Layout and Details
2Y20-22 B spacers are in place, all embedded items have been provided for and positioned according to the latest
drawings of all disciplines, joints have been provided correctly, and after the contractor has inspected
it himself. The contractor shall give at least 48 hours notice to the engineer
10.The contractor must ensure that spacing tolerances are strictly adhered to and that the reinforcement and APPROVED BY GECOR ENGINEERS
all cast in items stay in position during concreting
11.Allowable reinforcing placing tolerances to be as follows:
18Y10-SA-250 Stir (Beam Stirrups)
18Y10-SA-250 Stir 18Y10-SA-250 Stir 13Y10-SA-250 Stir
Position of reinforcement tolerance (mm)
RC Base Type A RC Base BA a) Spacing between any two adjacent bars in one layer
13R10-SC-250 Stir ENGINEER/TECHNOLOGIST REG. NO. DATE
a) slabs and walls +25/-25
b) beam stems and columns +25/-5
SCALE AS SHOWN DRAWN R.N
b) Stirrup spacing +15/-15
c) Longitudinal location of bends and
DESIGNED RN CHECKED RC
Ends of bars +50/-50
PLAN VIEW: GROUND BEAM REINFORCEMENT LAYOUT d) Distance between bars in successive FOR CONSTRUCTION
PLAN NUMBER REVISION NO. DATE SAVED
Scale 1:50 Parallel layers +10/-0
e) Liquid retaining structures +10/-10 PAPER SIZE A1
219090-400-RS-05 01 06 Aug 2019