Amman 10/9/2018
Ref: CB /PT /01/18
M.S Al Shabab Contracting Company
Attention Eng. Osama AL- Aqrabawi

Project : Khalda Commercial Building

Subject : PT Slabs

Dear Sir,
Reference is made to the above mentioned project subject, we have been reviewing
projects design, made an assessment and came out with the following:
Basement 1, Mezzanine, GF ,1st,2nd,3rd,4thFloors (Approx. Area 21800M2).

Basement 1 Floor

- Geometry as per drawings


- Superimposed dead load excluding self weight kN/m2 : 5.0
- Service live load kN/m2 : 5.0
- Concrete cylinder strength @ 28 days MPa (40 Mpa cube) : 32
- All flat two-way post-tensioned slab thickness mm : 350/320
- Drop Caps (3500x3500x700) mm Included Slab thickness
- Perimeter Beams (400x700) mm Included Slab thickness
- Re-bar rate kg/m2 : 19-20

Mezzanine Floor

- Geometry as per drawings


- Superimposed dead load excluding self weight kN/m2 : 5.0
- Service live load kN/m2 : 5.0
- Concrete cylinder strength @ 28 days MPa (40 Mpa cube) : 32
- All flat two-way post-tensioned slab thickness mm : 350
- Drop Caps (4000x4000x700) mm Included Slab thickness
- Perimeter Beams (1000x700) mm included slab thickness
- Re-bar rate kg/m2 : 19-20

82 Issam Ajlouni Street – Shmeisani


P.O.Box 830681 Amman 11183 , Jordan – Tel: + 962 6 5699013 , Fax : +962 6 5699014
d.bseiso@bemcoengineering.com , www.bemcoengineering.com
‫وو ر ه‬ ‫درو ش‬ ‫ر‬

Ground Floor

- Geometry as per drawings


- Superimposed dead load excluding self weight kN/m2 : 5.0
- Service live load kN/m2 : 5.0
- Concrete cylinder strength @ 28 days MPa (40 Mpa cube) : 32
- All flat two-way post-tensioned slab thickness mm : 350
- Drop Caps (3500x3500x700) mm Included Slab thickness
- Perimeter Beams (250x700) mm included slab thickness
- Re-bar rate kg/m2 : 19-20

1st &2nd&3rd Floors

- Geometry as per drawings


- Superimposed dead load excluding self weight kN/m2 : 5.0
- Service live load kN/m2 : 5.0
- Concrete cylinder strength @ 28 days MPa (40 Mpa cube) : 32
- All flat two-way post-tensioned slab thickness mm : 350
- Drop Caps (3500x3500x700) mm Included Slab thickness
- Perimeter Beams (250x700) mm included slab thickness
- Re-bar rate kg/m2 : 19-20

4th Floor

- Geometry as per drawings


- Superimposed dead load excluding self weight kN/m2 : 5.0
- Service live load kN/m2 : 3.0
- Concrete cylinder strength @ 28 days MPa (40 Mpa cube) : 32
- All flat two-way post-tensioned slab thickness mm : 350/370
- Drop Caps (3500x3500x700) mm Included Slab thickness
- Perimeter Beams (250x700) mm included slab thickness
- Re-bar rate kg/m2 : 19-20

- Price JOD 11.00 / M2 (Eleven Jordan Dinars per Square Meters) .


Price Includes Design, Workshop Drawings, All post Tension Materials, Installation
Slabs, Stressing & Grouting .

82 Issam Ajlouni Street – Shmeisani


P.O.Box 830681 Amman 11183 , Jordan – Tel: + 962 6 5699013 , Fax : +962 6 5699014
d.bseiso@bemcoengineering.com , www.bemcoengineering.com
Scope of Work:

- Supply of PT detailed shop drawings and design calculations to


the Consultant for approval as necessary for the execution of the
post-tensioned slabs .

- Supply of Post-Tension materials delivered to site including


customs and other duties .

• Pre-stressing 7-wires strands 15.7 mm, 15.2 mm or 0.6’’ diameter.


According to BS, EN or ASTM, all acquired from the highly renowned
strand specialists 'Maadaniyah' based in Saudi Arabia.
• Bright steel ducts and relevant duct couplers
• Complete sets of live anchorages from the OVM Company.
• Pre-stressing accessories including vent pipes, polystyrene
pocket formers and heavy duty tape for fixing the ducts .
• Additives necessary for the ducts grouting.

- Provide qualified personnel and superintendants to perform


the following works:

• Installation and fixing of ducts to chairs to be supplied cut


and bent.
• Threading of strands into ducts
• Anchorages setting and fixing to formwork
• Stressing of tendons and cutting tendon tails
• Grouting of tendons
* Mobilization and demobilization

"THE CLIENT’S" / Main – Contractor's obligations

The responsibilities of THE CLIENT/Main Contractor are detailed as follows :

Provide THE POST- TENSIONING CONTRACTOR with comprehensive and


accurate technical information and documents as necessary for the design
of post-tensioning elements (on electronic format) and take responsibility of
their accuracy.
• Insure convenient access to the site for THE POST- TENSIONING
CONTRACTOR’ material, equipment and staff.

• Provide suitable electrical power, water to the points of use.

• Provide necessary scaffolding, platform, support structure,


timber and planks for performing all pre-stressing works
mainly the stressing and grouting of tendons .

• Supply, installation and removal of all block outs,


recesses or special formwork if required in the vicinity of anchorages.

• Supply and placing of all reinforcing steel including bursting


reinforcement and all other end block reinforcement as well as steel
chairs for fixing the ducts.

• Supply, placing, vibrating and finishing of concrete including filling or


dry packing of block outs recesses.

• Supply of fresh Portland cement in bags for grouting

• Cutting and cleaning grout vents after grout setting

Payment terms

40% Of the Total value Advance Payment upon signing the Contract
40% Upon ordering of Materials .
20% Upon Completion of stressing and Grouting .

or to be agreed

Note: (100% of The Value for Slab will be paid upon completing
Grouting) No Retention is considered .
*** Prestressing steel Strands based on USD 1150/ MT as of 1/8/2018
Price Based on JOD/ U$D Exchange Rate as per CBJ rate of
10/9/2018 .
Any change in price, or Rate will be adjusted accordingly
Regards

Ahmad Qunies