13S4P PHEV-1 | Battery 240 Ah | Version 1.1 A 1 of 1
Tools: - Voltmeter - Laboratory power supply (min. 40V / 5A or more)
Procedure:
1. Measure the battery voltage with a
voltmeter 2. Adjust the power supply to the measured voltage 3. Limit the current to 1A 4. Switch on the output of the power supply 5. Connect power supply to battery as shown on the picture
Plus-Pole
6. Turn up the voltage to max. 48V
7. Slowly turn up the current limit to max. (depends on the wires and connectors) 8. The voltage should increase quickly and continuously (if voltage does NOT increase cancel the operation immediately)
Minus-Pole
9. Charge up to min. 40V
10. Switch off the power supply 11. Disconnect the power supply 12. Maybe you have to delete error memory 13. Continue charging with regular Linde charger