Sei sulla pagina 1di 2

Connected Load

Load Description Quantity Watts Hour use Watt-Hour


light 4 7 8 224
ref 1 200 24 4800
electric fan 1 60 2 120
rice cooker 1 300 1.5 450
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Total 567 5594

Solar Panel Demand Load


Connected Load (Watt-Hr) Average Sunlight Correction Factor for Losses
5594 5 30%

Total Number Of Solar Panel


Demand Load (Watt-Hr) Panel Capacity (Watts) Calculated No. Of Panel
1,454.44 250 5.82

Charge Controller Capacity


Total Panel Capacity (Watt) Nominal Voltage (DC) Allowable Capacity (%)
1500 24 80%

Baterry Capacity
Connected Load (Watt-Hr) Nominal Voltage (DC) Allowable Discharge (%)
5594 24 40%

Inverter Capacity
Total Load Capacity (Watts) Allowable Loading (%) Capacity (Watts)
567 80% 708.75
Demand Load (Watt-Hr)
1,454.44

Actual No. Of Panel


6

Capacity
Calculated Capacity (Amp-Hr) Actual Capacity
78.13 80

acity
No. Of Back Up Days Capacity (Amp-Hr)
1 582.71