DSE4610/20 ENVIRONMENTAL TESTING STANDARDS

AUTO START AND AUTO MAINS FAILURE ELECTRO-MAGNETIC COMPATIBILITY


CONTROL MODULES BS EN 61000-6-2
EMC Generic Immunity Standard for
the Industrial Environment
(ALTERNATOR FREQUENCY & MAGNETIC PICK-UP SPEED SENSING) BS EN 61000-6-4
EMC Generic Emission Standard for
the Industrial Environment

ELECTRICAL SAFETY
FEATURES BS EN 60950
Safety of Information Technology Equipment,
including Electrical Business Equipment

TEMPERATURE
The DSE4610 Auto Start Control Monitoring engine speed, oil Through USB Communication both BS EN 60068-2-1
Module and the DSE4620 Auto pressure, coolant temperature, modules can be easily configured Ab/Ae Cold Test -30 oC
Mains (Utility) Failure Control frequency, voltage, current, power using the DSE Configuration Suite BS EN 60068-2-2
Bb/Be Dry Heat +70 oC
Module are suitable for a wide and fuel level, the modules will give PC Software or can be fully
variety of single gen-set comprehensive engine and configured through the module's VIBRATION
BS EN 60068-2-6
applications. alternator protection. This will be front panel editor. Ten sweeps in each of three
indicated on the largest back-lit major axes
Whilst maintaining functions LCD icon display in its class via an All DSE products are supported by 5 Hz to 8 Hz at +/-7.5 mm,
8 Hz to 500 Hz at 2 gn
included within higher end array of warning, electrical trip and the DSE global technical support
controllers, such as generator or shutdown alarms. team which gives our customers HUMIDITY
BS EN 60068-2-30
load power monitoring, the and end users access to 24 hour Db Damp Heat Cyclic 20/55 oC
DSE46xx range of especially Alternator frequency & magnetic system help and advice. at 95% RH 48 Hours
compact controllers provide the pick up speed sensing support for BS EN 60068-2-78
Cab Damp Heat Static 40 oC
user with the ultimate size to diesel, gas and petrol engines all in at 93% RH 48 Hours
feature ratio. one variant. With a number of
SHOCK
flexible inputs, outputs and BS EN 60068-2-27
protections, the modules can be Three shocks in each of three major axes
easily adapted to suit a wide range 15 gn in 11 mS
of applications including lighting DEGREES OF PROTECTION
towers with the added option for PROVIDED BY ENCLOSURES
BS EN 60529
staged loading outputs. IP65 - Front of module when installed into the
control panel with the optional sealing gasket.

COMPREHENSIVE FEATURE LIST TO SUIT A


WIDE VARIETY OF GEN-SET APPLICATIONS
PC

4 4 3

USB CONFIGURABLE DC OUTPUT ANALOGUE SENDERS DC POWER


PORT INPUTS (2 for DSE4610) SUPPLY

DSE4610/20
7

OTHER

MAINS (UTILITY) DC OUTPUT GENERATOR / DC OUTPUT GENERATOR CHARGE FUEL AND MAGNETIC PICK-UP
SENSING 1 OF 4 4620 LOAD CURRENT 1 OF 4 4620 SENSING ALTERNATOR CRANK OUTPUTS
(DSE4620) 1 OF 2 4610

VOLTS VOLTS
D+ +
+ + W/L

1ph 1 1ph 1 1ph


2ph 2ph 2ph
3ph 3ph 3ph
N N

ISSUE 1
®

DSEGenset

DSE4610/20 SPECIFICATION

AUTO START AND AUTO MAINS FAILURE DC SUPPLY


CONTINUOUS VOLTAGE RATING
CONTROL MODULES 8 V to 35 V Continuous

CRANKING DROPOUTS
(ALTERNATOR FREQUENCY & MAGNETIC PICK-UP SPEED SENSING) Able to survive 0 V for 50 mS, providing
supply was at least 10 V before dropout and
supply recovers to 5 V. This is achieved
without the need for internal batteries.
FEATURES LEDs and backlight will not be maintained
during cranking.

MAXIMUM OPERATING CURRENT


DSE4620 85 mA at 12 V, 96 mA at 24 V

MAXIMUM STANDBY CURRENT


51 mA at 12 V, 47 mA at 24 V

MAXIMUM SLEEP CURRENT


35 mA at 12 V, 32 mA at 24 V
DSE4610
MAXIMUM DEEP SLEEP CURRENT
<10 uA at 12 V, <10 uA at 24 V

MAINS (UTILITY) DSE4620 ONLY


VOLTAGE RANGE
15 V to 415 V AC (Ph to N)
26 V to 719 V AC (Ph to Ph)

FREQUENCY RANGE
3.5 Hz to 75 Hz

OUTPUTS
OUTPUT A (FUEL)
10 A short term, 5 A continuous,
at supply voltage

OUTPUT B (START)
10 A short term, 5 A continuous,
at supply voltage

AUXILIARY OUTPUTS C & D


2 A DC at supply voltage
KEY BENEFITS KEY FEATURES • 4 configurable digital inputs
• Ultimate size to feature ratio • Alternator frequency & MPU • Configurable staged loading AUXILIARY OUTPUTS E & F DSE4620
2 A DC at supply voltage
• Automatically transfers between speed sensing in one variant outputs
mains (utility) and generator • Largest back-lit icon display in • 3 engine maintainance alarms GENERATOR
(DSE4620 only) its class • Engine speed protection VOLTAGE RANGE
15 V to 415 V AC (Ph to N)
• Hours counter provides accurate • Real time clock provides • Engine hours counter 26 V to 719 V AC (Ph to Ph)
information for monitoring and accurate event logging • Engine pre-heat
maintenance periods • Fully configurable via the fascia • Engine run-time scheduler FREQUENCY RANGE
3.5 Hz to 75 Hz
• User-friendly set-up and button or PC using USB • Battery voltage monitoring
layout for ease of use communication • Start on low battery voltage MAGNETIC PICK UP
• Multiple parameters are • Extremely efficient power save • Configurable remote start input VOLTAGE RANGE
+/- 0.5 V to 70 V
monitored simultaneously which mode • 1 alternative configuration
are clearly displayed on the • 3 phase generator sensing • Comprehensive warning, FREQUENCY RANGE
largest back-lit icon display in • 3 phase mains (utility) sensing electrical trip or shutdown 10,000 Hz (max)

its class (DSE4620 only) protection upon fault condition DIMENSIONS


• The module can be configured • Generator/load power • LCD alarm indication OVERALL
to suit a wide range of monitoring (kW, kV A, kV Ar, pf) • Event log (50) 140 mm x 113 mm x 43 mm
5.5’’ x 4.4” x 1.7”
applications • Generator/load current
• Uses DSE Configuration Suite monitoring and protection PANEL CUT-OUT
PC Software for simplified • Fuel and crank outputs 118 mm x 92 mm
4.6’’ x 3.6”
configuration • Compatible with 600 V ph to ph
• Licence-free PC software nominal systems MAXIMUM PANEL THICKNESS
• IP65 rating (with optional • 4 configurable DC outputs 8 mm
0.3”
gasket) offers increased • 3 configurable analogue/digital

-40 °C to +85 °C
resistance to water ingress inputs STORAGE TEMPERATURE RANGE

-40 °F to +185 °F
RELATED MATERIALS
-30 °C to +70 °C
OPERATING TEMPERATURE RANGE
TITLE PART NO’S
DSE4610/20 Installation Instructions 053-156 -22 °F to +158 °F
DSE4610/20 Operator Manual 057-200
DSE4610/20 Configuration Suite PC Manual 057-201
OPTIONAL PARTS

PART PART NUMBER


IP65 Gasket 020-282

DEEP SEA ELECTRONICS PLC UK DEEP SEA ELECTRONICS INC USA


Highfield House, Hunmanby Industrial Estate, Hunmanby YO14 0PH 3230 Williams Avenue, Rockford, IL 61101-2668 USA
TELEPHONE +44 (0) 1723 890099 FACSIMILE +44 (0) 1723 893303 TELEPHONE +1 (815) 316 8706 FACSIMILE +1 (815) 316 8708
EMAIL sales@deepseaplc.com WEBSITE www.deepseaplc.com EMAIL sales@deepseausa.com WEBSITE www.deepseausa.com

Deep Sea Electronics Plc maintains a policy of continuous development and reserves the right to change Registered in England & Wales No.01319649 055-165/06/13 (2)
the details shown on this data sheet without prior notice. The contents are intended for guidance only. VAT No.316923457

Potrebbero piacerti anche