Sei sulla pagina 1di 3

Design code: EN 14015

1. Tank design input summary

Internal shell diameter D=   13.000,00 
mm Shell height H=  16.000,00  mm
Number of courses: 7
Roof type: Sloped, conical, with rafters
Roof diameter: 13016,00 mm Slope angle: θ=           10,00  degrees
Roof radius R= 6608,40 mm Radius of roof curvature: R1=           37,48  m
Fluid name:
Max capacity:     8.494,87  m3 (Volume between tank bottom and the top)

Maximum design density ρ=           0,775  kg/l 775,00 kg/m3 (Storage conditions)


ρt=             1,00  kg/l 1000,00 kg/m3 (Test conditions)
Pressure:
Operating:                2,0  kPa        20,00  mbar
Design: p=                1,0  kPa        10,00  mbar  1.000,00  N/m2
Vacuum pressure: pv=                0,5  kPa          5,00  mbar (5.1 Table 3)
Hydrostatic liquid level:     16.050,0  mm
Test pressure, Section 9.2.2 pt=                1,1  kPa          11,0  mbar

Trmperature:
Max operating temperature:           40,00  °C
LODMAT: ‐          21,00  °C
Min design metal temp.: ‐          28,00  °C
Max design temp.:           60,00  °C

Corrosion allowance:
Shell:   3,00  mm Bottom:             3,00  mm
Roof:   1,00  mm (Steel plates internal and external painting is mandatory)

Nominal plates widths:
First lowest shell course 1 2000,00 mm
2 2000,00 mm
3 2000,00 mm
4 2000,00 mm
5 2000,00 mm
6 2000,00 mm
7 2000,00 mm
8 2000,00 mm
9 0,00 mm
10 0,00 mm

Max liquid level:
HHLL: 15000,00 mm
Failure case: ‐ mm

Load data:
Wind load:             0,58  kN/m2      580,00  N/m2
Zone wind velocity:           30,00  m/s      108,00  km/h
3 sec. Wind gust velocity (SR EN 14015):           45,00  m/s      162,00  km/h
Snow load:             2,00  kPa  2.000,00  N/m2
Live load (roof):             2,50  kPa  2.500,00  N/m2

Seismic load:
Period of contrac. Tc=             1,60  s
Acceleration             0,25  *g
Lateral force coeff. G1=             0,25 
Site coeff. j=             1,50  (Table G.1)

Insulation: no ‐ mm

Material and mechanical properties of steel plates:
Max 
Minimum  allowable 
tensile  Minimum yield  design  Max allowable 
strength  strength  stress  hydrotest 
Material [N/mm2] [N/mm2] [N/mm2] [N/mm2]
Ft Fy S St
Roof S235J0 430,00 235,00 156,67 176,25
Shell S235J0 430,00 235,00 156,67 176,25
Bottom S235J0 430,00 235,00 156,67 176,25

2. Shell design

Minimum shell thickness as per 9.1.5 (Table 16):
tmin= 5 mm
Shell thickness calculation (acc to 9.2.2):

Design thk  Min thk  Actual thk 


Course Height [mm] Hydro thk [mm] Weight [kg]
[mm] [mm] [mm]
Hc ec et emin e
1 16000,00 7,989 5,715 7,989 8 O.K. 5132,75
2 14000,00 7,359 4,992 7,359 8 O.K. 5132,75
3 12000,00 6,728 4,269 6,728 7 O.K. 4490,81
4 10000,00 6,098 3,546 6,098 7 O.K. 4490,81
5 8000,00 5,468 2,823 5,468 7 O.K. 4490,81
6 6000,00 4,838 2,101 5,000 7 O.K. 4490,81
7 4000,00 4,207 1,378 5,000 7 O.K. 4490,81
8 2000,00 3,577 0,655 5,000 7 O.K. 4490,81
9 0,00 ‐ ‐ ‐ ‐ ‐ ‐
10 0,00 ‐ ‐ ‐ ‐ ‐ ‐
 37210,36

3. Bottom plate design

Minimum thickness as per 8.2.3 (Table 13):   6,00  mm
Adding corrosion allowance, required thickness is:   9,00  mm
Therefore, use thickness of: eb=   9,00  mm is satisfactory

Minimum width of plates overlaping as per 8.1 (Figure 3): 45,00 mm

4. Annular plate design

As per 8.3.1, this tank SHALL HAVE a ring of annular bottom plates.

As per 8.3.1, min thickness of the plate is:   6,00  mm
Adding corrosion allowance, required thickness is:   9,00  mm
Therefore, use thickness of: ea=   9,00  mm is satisfactory

Thr minimum width la as per 8.3.3 is: 540,00 mm
Therefore, use width of: la= 540,00 mm is satisfactory.

The distance ld ‐ outside projection of annular plates shall be in the interval 50 to 100 mm (as per 8.3.3):
Therefore, use width of:                 ld= 50,00 mm is satisfactory.

Minimum width of bottom and annular plates overlaping, as per 8.4.1, is: 60,00 mm
Therefore, use width of: lw= 60,00 mm is satisfactory.

Total width of annular plate is: 658,00 mm

5. Intermediate wind girders

As per 9.3.3.1, minimum dimensions of angle (shown on detail c) is: L 100x65x8

Shell 
thickness  Unit weight of 
corroded  Actual plate  Transposed  wind girder 
Course [mm] width [m] widht [m] [kg/m]
1 5,00 2,00 1,14 9,86 kg/m
2 5,00 2,00 1,14
3 4,00 2,00 2,00
4 4,00 2,00 2,00
5 4,00 2,00 2,00
6 4,00 2,00 2,00
7 4,00 2,00 2,00
8 4,00 2,00 2,00
9 ‐ ‐ ‐
10 ‐ ‐ ‐

HE= 14,29 m ‐ eqvivalent stable full shell height

Factor K: K= 9,39

Maximum permitted spacing of secondary stiffening rings:
Hp= 6,41 m

Hp < HE, therefore the intermediate wind girder is/are required.

Minimum number of intermediate wind girders required is 2

Location of intermedaite wind girders from top of the tank: Weight [kg]
1 4,76 m 402,69
2 9,53 m 402,69
3 ‐ m ‐
4 ‐ m ‐
5 ‐ m ‐

6. Roof plate design

Minimum thickness as per 10.3.3:   5,00  mm
Adding corrosion allowance, required thickness is:   6,00  mm
Therefore, use thickness of: er=   7,00  mm is satisfactory

7. Roof‐to‐shell joint design

The compresion roof area: A r= 2151,23 mm2

The compresion shell area: As = 903,33 mm2

As per 10.5.2, allowable compressive stress: Sc= 120 N/mm2

The compresion area to be provided: A= 461,33 mm2

Minimum size of top corner ring: L 60x60x6 Actual size of sompresion ring:    L 60x60x6

The compresion angle area: Aa= 684 mm2

A < Aa + Ar + As Size of compresion ring is satisfactory.

8. Weight summary

Shell courses: 37210,36 kg

Bottom plates: 9545,64 kg

Compresion ring:
Unit weight of actual compression ring is: 5,369 kg/m
Total weight of compression ring is: 219,51 kg

Weight of intermediate wind girders: 805,38 kg

Roof plates: 7538,93 kg

Miscellaneous:
Assuming 10,00 % of total weight: 5531,98 kg

Operating liquid weight: 1543012,87 kg

Hydrostatic liquid weight: 2123716,63 kg

ERECTION WEIGHT:         60.852  kg
OPERATING WEIGHT:   1.603.865  kg
HYDROSTATIC TEST WEIGHT:   2.184.568  kg