Sei sulla pagina 1di 8

CIDCO OF MAHARASHTRA LIMITED. Sl.Pg.No.

450
C.A.NO. 08/CIDCO/RP/SE(TP-III&HQ)/EE(BPR-I)/2010-11

CHECKLIST FOR READY MIX CONCRETE

SUPPLY OF CONCRETE (RMC)

Name of Work :

C.A.No. :

Name of Contractor/Client :

Sr.
Description Detail Information
No.
1. Name of RMC manufacturer with plant
address & telephone nos.

2. Name of Plant In Charge with


qualification & Experience

3. Date of commissioning of RMC plant

4. RMC Plant details

a) Capacity of plant Design


Actual Output

b) Whether plant fully automatic/Semi


automatic

c) Conveyor belt for loading aggregate

d) Aggregate bin with various


compartments for different aggregate

e) Mixer type

f) No. of Transit Mixers with capacity

g) No. of pumps

h) No. of placer boom

i) i) Separate silos with capacity for


Cement
ii) Fly ash

j) Water storage arrangement


CIDCO OF MAHARASHTRA LIMITED. Sl.Pg.No. 451
C.A.NO. 08/CIDCO/RP/SE(TP-III&HQ)/EE(BPR-I)/2010-11

Sr.
Description Detail Information
No.
k) Plasticizer arrangement

l) Arrangement for alternate power


supply

m) Arrangement for maintenance of P &


M.

n) Storage capacity for raw materials

o) Arrangement for curing tank &


frequency of changing water

p) Calibration frequency of plant with


traceability

q) Whether you observe the


accuracy/sensitivity of measuring
equipments within the limits of IS
4926:2003

r) Details of Calibration frequency of


various testing equipments with
traceability & its record

5. Quantity of RMC manufactured daily

M20

M25

M30

M35

6. Source of materials

Cement-whether bulk supply

Coarse aggregate

Fine aggregate – Sand

Crushed Sand

Water
CIDCO OF MAHARASHTRA LIMITED. Sl.Pg.No. 452
C.A.NO. 08/CIDCO/RP/SE(TP-III&HQ)/EE(BPR-I)/2010-11

Sr.
Description Detail Information
No.
Chemical Admixture

Mineral Admixture (Fly ash)

7. Details of quality control testing &


records of various constituents
materials

A) Cement (IS 8112, IS 12269)

Whether MTC
(weekwise) available

Fineness

Soundness

IST & FST

Consistency

Compressive strength of cement


mortar cubes-no. of cubes

Chemical tests

Physical & chemical testing at external


lab. & its frequency

B) Coarse Aggregate (IS 383 : 1970)

Gradation

Specific gravity

Flakiness & elongation Index

Impact value/Crushing value/ Abrasion


value

Soundness

Alkali Aggregate reactivity test


CIDCO OF MAHARASHTRA LIMITED. Sl.Pg.No. 453
C.A.NO. 08/CIDCO/RP/SE(TP-III&HQ)/EE(BPR-I)/2010-11

Sr.
Description Detail Information
No.
C) Fine aggregates (IS 383 : 1970)

Specific gravity

Determination of clay, fine silts, & fines


dust

Free moisture content

Soundness

Water absorption

Organic impurities

D) Admixture (IS 9103 : 1999)

Whether MTC is available for every


batch & brand

Dry Material content

pH value

Relative Density

Compatibility

Ash content

Chloride ion content

Performance test for slump retention &


compressive strength test at 24hr. on
control mix.

Periodical testing at external lab. For


crosscheck

E) Fly ash
(IS 3812 : 2003)
CIDCO OF MAHARASHTRA LIMITED. Sl.Pg.No. 454
C.A.NO. 08/CIDCO/RP/SE(TP-III&HQ)/EE(BPR-I)/2010-11

Sr.
Description Detail Information
No.
Whether MTC available
Physical properties
1. Specific surface
2. Residue on 45 micron IS sieve
3. Lime reactivity
4. Comp. Strength
5. Soundness

Chemical properties chemical Analysis

Periodical testing at external lab. For


crosscheck

F) Water (IS 456 : 2000, IS 3025 : 1964)

pH value

Sulphates

Chlorides

Organic matter

Suspended matter

Periodical testing at external lab. For


crosscheck

G) Concrete (RMC)

a) Mix Design & Trial Mixes

Method of design

(whether as per IS or any other)

b. Whether it is as per requirement of


client or your own

b) Daily check on preparation of starting


slips for each of grades based on
CIDCO OF MAHARASHTRA LIMITED. Sl.Pg.No. 455
C.A.NO. 08/CIDCO/RP/SE(TP-III&HQ)/EE(BPR-I)/2010-11

Sr.
Description Detail Information
No.
adjustments of moisture content or
water absorption (at 7,11,15,19 hr.) as
per schedule

c) Analysis of fresh concrete Mix as per IS


1199 – 1959.

d) Temperature of the fresh Concrete Mix

e) Slump at the Plant

f) Check for Density for each grade

g) Cube Comprehensive Strength &


Acceptability Records of tests

h) Permeability apparatus

i) NDT equipments & co-relation with


cube compressive strength

j) Cement content test

k) Chemical analysis of concrete samples

l) Statistical analysis of test results &


modification to the mix proportion
based on standard deviation of plant

m) Special Precautions taken

a. During Rainy season

b. During Hot season

8. Technical staff available at plant with


qualification & experience

9. Technical Staff to accompany transit


mixer with qualification & experience

10. Time of availability of RMC supply

11. Delivery tickets as per Annex G (Cl.9.4)


of IS 4926-2003
(Alongwith every load/transit mixer)
CIDCO OF MAHARASHTRA LIMITED. Sl.Pg.No. 456
C.A.NO. 08/CIDCO/RP/SE(TP-III&HQ)/EE(BPR-I)/2010-11

Sr.
Description Detail Information
No.
12. Test frequency for all whether as per IS
4926-2003

13. Any incidents of failure in quality


supplied

14. Any incidents of failure in timely supply

15. Details of works where RMC used

Major Clients

16. Any other information

17. Third Party Inspection Name of agency,


Frequency & Report.

18. Monitoring of Ready mixed Concrete


as per IS 4926:2003

a) If more than one admixture is used,


confirmation of their compatibility

b) IST & FST of concrete when admixture


is used at adopted dosage (As per IS
8142)

c) Time of transportation (Shall not


exceed 2 hours for normal case.)

d) Frequency of Compressive strength


(One sample (3 specimens) for every
50 Cum or 50 batches whichever is
greater).
CIDCO OF MAHARASHTRA LIMITED. Sl.Pg.No. 457
C.A.NO. 08/CIDCO/RP/SE(TP-III&HQ)/EE(BPR-I)/2010-11

Sr.
Description Detail Information
No.
e) Any additional compliance criteria
shall be declared to the producer by
the purchaser prior to supply & shall
be mutually agreed upon.

f) The action to be taken in case of non-


compliance shall be declared &
mutually agreed upon.

Also enclosed herewith Annex –I i.e. Material Testing requirements as per IS 4926 :
2003.

Signature of RMC Supplier

M/s.

Name

Checked by

Potrebbero piacerti anche