HUDA: Submission drawing protocol

Haryana Urban Development Authority has planned to automate the building plan approval process by
introducing AutoDCR system. AutoDCR software reads the CAD drawings submitted by architects and
automatically produce the deviation report based on the control regulations prescribed by HUDA.
The purpose of this document is to establish a set of guidelines to Architects for preparation of drawings to be
submitted for taking Building Permission from HUDA, Uniformity in the process of drafting of the drawings to
be submitted for approval is required for automation of building approval system by introducing AutoDCR
system.
The consultants/Architects should prepare the drawings keeping specific objects in specific layers with specific
colors and text. The layers required to be generated with explanation of what is required to be drawn on
which layer is described in this document. This document serves as a source of information on obtaining level
of consistency in drafting and approval process focuses on both the theoretical and practical description of
process flow and protocol to be used while preparing drawings for submission at HUDA for Building
Permission.
Refer the following table for Layer names and their details.

Sr. Layer Name Color Name Text Name Where to draw Remark
No. & numbers
1 _Amenity_GrpHsg Cyan Text should be kept on Inside Plot Polyline
same layer and color.
2 _ArchProj 21 Text should be kept on Inside Floor Floor Bed, Cobbord,chajja
same layer and color. Polyline cornice, Loft,
Canopy, Porch, Verandah,
Otta, Steps, Bay Window,
Parabola. Should be drawn
on this layer.
3 _Balcony 25 Text should be kept on Inside Floor & Plot
same layer and color. Polyline
4 _Barsati 141 Text should be kept on Inside Floor
same layer and color. Polyline
5 _BoundaryWall 252 Text should be kept on Inside Plot Polyline
same layer and color.
6 _Building 52 Text should be kept on Out Side Plot
same layer and color. Polyline
7 _CarpetArea 191 Text should be kept on Inside Floor
same layer and color. Polyline
8 _Column 29 Not need text of this Inside Floor
layer. Polyline
9 _CommFAR 150 Not need text of this Inside Floor
layer. Polyline
10 _Connecting 200 Text should be kept on Inside Plot Polyline
Slab same layer and color.

11 _Courtyard 180 Text should be kept on Inside Floor


same layer and color. Polyline
12 _Door 114 Text should be kept on Inside Floor
same layer and color. Polyline
13 _Elevation 44 Not need text of this Inside With in
layer. building
14 _ExStructure Blue Text should be kept on Inside Plot Polyline
same layer and color.
15 _Floor 153 Text should be kept on Inside building
same layer and color. Polyline
16 _FloorInSectio 132 Text should be kept on Inside building
n same layer and color. Polyline

17 _Gate 37 Text should be kept on Inside Plot Polyline Main Gate, Wicket gate, gate
same layer and color. (default) should be drawn on
this layer.
18 _GroundLevel 63 Text should be kept on Inside Floor
same layer and color. Polyline
19 _Handrail 155 Text should be kept on Inside Floor
same layer and color. Polyline
20 _IndFAR 163 Not need text of this Inside Floor
layer. Polyline
21 _InternalRoad_ Green Text should be kept on Inside Plot Polyline
GrpHsg same layer and color.

22 _LiftWell 171 Text should be kept on Inside Floor Normal (Default), Hydraulic, Fire
same layer and color. Polyline Lift, Lift for Handicapped, Open
Lift, Should be drawn on this
layer.
23 _Location Plan 211 Text should be kept on Inside Building
same layer and color. Polyline
24 _MainRoad 20 Text should be kept on Should be Overlap
same layer and color. on Plot layer
25 _MarginLine 253 Not need text of this Should be Overlap
layer. on Plot layer
26 _NETPLOT 145 Not need text of this Should be Overlap
layer. on Plot layer
27 _Parking 60 Text should be kept on Inside Floor & Plot Car L. (2.5x5.0), Scooter, Cycle,
same layer and color. Polyline Loading/Unloading, Transport
Vehicle, Should be drawn on this
layer.
28 _Passage 243 Text should be kept on Inside Floor
same layer and color. Polyline
29 _Plot White Text should be kept on Out Side from the
same layer and color. building polyline
30 _Podium 50 Text should be kept on Inside Plot Polyline
same layer and color.
31 _PrintAddition 223 Not need text of this Inside Floor
alDetail layer. Polyline
32 _PropWork Red Text should be kept on Inside Plot Polyline.
same layer and color.
33 _PublicHealthD 24 Text should be kept on Inside Floor & Plot
etails same layer and color. Polyline
34 _Ramp 135 Text should be kept on Inside Floor & Plot
same layer and color. Polyline
35 _RecreationalG Yellow Text should be kept on Inside Plot Polyline
nd_GrpHsg same layer and color.
36 _RefugeArea 79 Text should be kept on Inside Floor
same layer and color. Polyline
37 _ResiFAR 190 Not need text of this Inside Floor
layer. Polyline
38 _Room 72 Text should be kept on Inside Floor
same layer and color. Polyline
39 _Sanitation 119 Text should be kept on Inside Floor Urinal, washbasin, Drinking
same layer and color. Polyline water, Washing Tab, Ablution
Tab, Cleaner Sink, Kitchen Sink,
Washing Sink, Should be drawn
on this layer,
40 _Section 75 Text should be kept on Inside Floor
same layer and color. Polyline
41 _SewageLine 10 Text should be kept on Inside Plot Polyline
same layer and color.
42 _SitePlan 50 Text should be kept on Inside building
same layer and color. Polyline
43 _SpecialUseFA 213 Not need text of this Inside Floor
R layer. Polyline

44 _StairCase 120 Text should be kept on Inside Floor Intermediate landing, Flight
same layer and color. Polyline Width, Floor Landing.
Should be drawn on this layer.
45 _SubStructure 32 Text should be kept on Inside Floor & Plot Electric Room,Transformer,
same layer and color. Polyline Society office, Servent Quarter,
Sanatary block, Covered garage,
Rain water harvesting, A.C. plant
room, AHU,Swimming
pool,Septic tank,Punp
room,Effiuent treatment
plant/STD,Dish antenna room,
Teliphone Installlation
room,Control room, Teliphone
booth,Entrance foyer, Sport
Structure, Cycle/Scooter
Shelters. Solar Water heater
should be drawn on this layer.
47 _Tank 133 Text should be kept on Inside Floor & Plot Overhead water tank
same layer and color. Polyline Underground water tank
48 _Terrace 30 Text should be kept on Inside Floor
same layer and color. Polyline
49 _VentilationSh 83 Text should be kept on Inside Floor
aft same layer and color. Polyline
50 _Void 111 Text should be kept on Inside Floor
same layer and color. Polyline
51 _WaterLine 131 Text should be kept on Inside Plot Polyline
same layer and color.
52 _Window 115 Text should be kept on Inside Floor
same layer and color. Polyline