Sei sulla pagina 1di 1

CENTRILINE LEAD (CEL) FLAT

SPECIFICATION

PART NUMBER: 76153


DESCRIPTION: 2SOLBC 5KV DD13 LEAD BED GAL F

1. CONDUCTOR: 2AW G SOLID SDBC DIA = .258" 6.55 mm

2. INSULATION: DD13 EPDM, HIGH DIELECTRIC STRENGTH, 5KV DIA = .414" 10.52 mm
75 MIL MINIMUM AVG W ALL THICKNESS
78 MIL NOMINAL AVG W ALL THICKNESS
68 MIL MINIMUM THICKNESS AT ANY POINT

3. LEAD SHEATH: LEAD, SPECIAL FATIGUE RESISTANT


40 MIL MINIMUM AVG W ALL THICKNESS
43 MIL NOMINAL AVG W ALL THICKNESS
32 MIL MINIMUM THICKNESS AT ANY POINT

NOMINAL DIAMETER OVER LEAD SHEATH DIA = .500" 12.70 mm


MEETS ASTM B-29

4. BEDDING TAPE: BEDDING TAPE W ITH SBR (RUBBER) TO PROTECT


THE LEAD SHEATH DURING THE ARMOR OPERATION.
PROVIDES 100% PROTECTION TO THE LEAD SHEATH

5. OUTER ARMOR: GALVANIZED STEEL ARMOR, 1/2" X .020" COATED


ALL FOUR SIDES, NOMINAL DIAMETER OVER ARMOR = .626” x 1.628”
15.90 mm x 41.35 mm
NOMINAL W EIGHT PER FOOT = 2.11 POUNDS 3.14 kg/m

MARKER: IDENTIFICATION TAPE PLACED PARALLEL UNDER ARMOR


0 0
TEMPERATURE: TEMPERATURE RATING CENTRILINE LEAD SHEATH = -40 0 C T O 260 0 C
0 0
-40 F TO 500 F
TESTED: CONDUCTOR RESISTANCE = MAX. 0.162 OHMS/KFT
INSULATION RESISTANCE = MIN 3682 MEGOHMS/KFT
AC TEST (5MIN. @ 13KV) - DC TEST (5MIN. @ 35KV)
MAX DC LEAKAGE = 0.27/KV/KFT
ICEA, IEEE 1018, AND CENTRILIFT SPECIFICATIONS
Materials and specifications are subject to change without notice.

2 5 4

3 1
76153_2GAL.doc, Mar 18 2014, KM