Sei sulla pagina 1di 40

PD PA S PI ISD-ENV

Eng. Luis Luna

MAG 8000 powered by 3G technology


April 2018

Unrestricted © Siemens AG 2017 All rights reserved. siemens.com/mag8000


Agenda

⋅ Introduction
⋅ Working principle
people + products = success
⋅ Applications
⋅ Product Description
⋅ Basic Settings

SITRANS F M
MAG 8000

Unrestricted © Siemens AG 2017 All rights reserved.


Agenda

⋅ Introduction
⋅ Working principle
people + products = success
⋅ Applications
⋅ Product Description
⋅ Basic Settings

SITRANS F M
MAG 8000

Unrestricted © Siemens AG 2017 All rights reserved.


Target Markets SITRANS F M MAG 8000

Specially developed to stand-alone


water applications

Unrestricted © Siemens AG 2017 All rights reserved.


Agenda

⋅ Introduction
⋅ Working principle
people + products = success
⋅ GSM/GPRS Applications
⋅ Product Description
⋅ Basic Settings

SITRANS F M
MAG 8000

Unrestricted © Siemens AG 2017 All rights reserved.


Working principle

… is based on Faraday’s law:

Ui = L * B * v

Explanation:
The voltage Ui introduced at

B the ends of an electrical


L conductor of length L, when
is moved at velocity v,
perpendicular to the lines of
flux through a magnetic field
Ui
Battery
Normal DC
of strength B
Excitation Freq.
Excitation Freq.
1/15Hz
6,25Hz

Unrestricted © Siemens AG 2017 All rights reserved.


Working principle

Battery MAG meters can only measure:

Fluids with electrical


conductivity & clean medias
Some examples:
Yes No
ƒ Drinking Water ƒ Waste Water
ƒ Treated Water ƒ Demi Water
ƒ Irrigation Water ƒ Media w/solids

Typically above 20 µS/cm


Unrestricted © Siemens AG 2017 All rights reserved.
SITRANS F M MAG 8000
Benefits overview

• Locations without power


• Long battery lifetime up to 10 years
• Direct burial sensor design
• Easy installation
• Water metering / Billing
• High accuracy & repeatability
• Leak detection
• No pressure drop
• Advanced diagnostic functions
• Flexible communication program
(Modbus RTU, Sensus protocol and GSM/GPRS).

Unrestricted © Siemens AG 2017 All rights reserved.


SITRANS F M MAG 8000
Power management

• Up to 10 years battery operation without communication modules.


• Unique battery power management program
- Real power consumption including measurement,
communication and meter dialogue
- Customer selectable low power level for call up and
alarm registration
- Temperature included in energy consumption

100%

Customer
Alarm level

Unrestricted © Siemens AG 2017 All rights reserved.


SITRANS F M MAG 8000
Simple to install

• Compact/remote with factory mounted sensor cables with connectors


• IP68/NEMA 6P enclosure withstands flooding in underground
installation
• Insensitive installation with minimal inlet and outlet installation
requirements

Unrestricted © Siemens AG 2017 All rights reserved.


SITRANS F M MAG 8000
Superior Measurement

One cone down, internal in sensor


for better low flow detection with
insignificant pressure drop

No moving parts means


independent against particles in
water – ensuring high repeatability
of maximum uncertainty ±0.1%

Unrestricted © Siemens AG 2017 All rights reserved.


Magnetic flow meters vs Mechanical
Technical justification

Criteria Mag 8000 CT Mechanical Meters


Mechanical deterioration
Measurement
Metrological stability = metrological deterioration
Metrology = under metering

Configuration Configuration: compact & remote


ƒSensor: IP 68 – can be buried Compact system only
Installation ƒTransmitter: IP68 seal
easyness
Integral path « Mechanics » in line =
Head loss No head loss Important head losses

Flow direction Bi-directionnal measurement 1 flow direction only


Not influenced by:
ƒWater hammers As much factors affecting the
Factors of
ƒCritical operation cycles operation of mechanical
Influence ƒSuspended solids meters
ƒFlow direction inversion

Unrestricted © Siemens AG 2017 All rightsSustainability


Outcome reserved. Maintenance
Agenda

⋅ Introduction
⋅ Working principle
people + products = success
⋅ GSM/GPRS Applications
⋅ Product Description
⋅ Basic Settings

SITRANS F M
MAG 8000

Unrestricted © Siemens AG 2017 All rights reserved.


Applications SITRANS F M MAG 8000
Distribution network

For metering and leakage purposes


ƒ Flow data file via email using GPRS (different sample rates)
ƒ Alarms report via SMS
ƒ Data analysis for network efficiency and leakage detection
ƒ Accurate water consumption profiling
ƒ Transmission of data once a day

Unrestricted © Siemens AG 2017 All rights reserved.


Applications SITRANS F M MAG 8000
Bulk water and revenue

For metering and billing purposes (Custody Tranfer)


ƒ Flow data file via email using GPRS (different sample rates)
ƒ Totalized data via SMS using GSM (optional)
ƒ Alarms report via SMS
ƒ Data analysis for big users for consumption profiling
ƒ Daily, weekly or monthly accurate billing with optional trend
information
ƒ Transmission once a day
Unrestricted © Siemens AG 2017 All rights reserved.
Applications SITRANS F M MAG 8000
Irrigation

For metering and billing purposes


ƒ Flow, volume and pressure data file via email using GPRS (different sample
rates)
ƒ Totalized data via SMS using GSM (optional)
ƒ Alarms report via SMS
ƒ Data analysis for consumption profiling – smart irrigation –
ƒ Fast reaction to climate changes giving accurate irrigation
ƒ Transmission of data once a day
Unrestricted © Siemens AG 2017 All rights reserved.
Agenda

⋅ Introduction
⋅ Working principle
people + products = success
⋅ Applications
⋅ Product Description
⋅ Basic Settings

SITRANS F M
MAG 8000

Unrestricted © Siemens AG 2017 All rights reserved.


Product definition
MAG 8000 Wireless Communication Module (WCM)

ƒ The MAG 8000 WCM is a wireless


communication module based on the
GSM / GPRS technology
ƒ The WCM is a built-in system not
compromising the IP68 protection
degree of the MAG 8000 water meter
ƒ Optional two analogue inputs
- One standard 4–20 mA
(externally powered)
- One ratiometric input 5 V DC powered
by MAG 8000
ƒ Open Protocol Communication Server
for the data treatment

Unrestricted © Siemens AG 2017 All rights reserved.


Product definition
MAG 8000 Wireless Communication Module (WCM)

⋅ Different sample rates to offer open logs for various applications


⋅ Email deliver via a simple CSV file. (E.g sampling once a minute and
transmitting once a day, collected data around 1440 points).
⋅ Basic SMS reporting with TOT 1 values for billing purposes
⋅ Simple configuration via SMS commands
⋅ OPC server for data treatment (compatible with any OPC client for
viewing data)

Unrestricted © Siemens AG 2017 All rights reserved.


Product definition
MAG 8000 Wireless Communication Module (WCM)

⋅ Total battery calculation (MAG 8000 + GSM/GPRS module)


⋅ Typical lifetime transmitting once a day
- Internal battery 3 years

- External battery 7 years


⋅ Remote antenna 5 m cable length
⋅ MAG 8000 WCM is prepared for future upgrades for "always-on"
transmission mode and a Micro SD card storage (extend safety data log).

Unrestricted © Siemens AG 2017 All rights reserved.


Product definition
MAG 8000 WCM - Data flow

1. MAG 8000 with GSM / GPRS WCM


2. Mobile network 4
3. Internet service 3
4. Email with a “csv” file
SMTP
5. OPC HDA server solution
6. SMS data with TOT 1
7. SMS data via email
8. SMS data exported into a POP 3
datasheet
2
5

Pressure
Input
7

Unrestricted © Siemens AG 2017 All rights reserved.


Product definition
MAG 8000 WCM – Part description

Push button Indication LED


ON/OFF/Factory Reset ON/OFF/Factory Reset

Antenna connector
SIM Card / SD card
Combo Slot

Rechargeable Terminal connection


battery inlet for analog inputs

Unrestricted © Siemens AG 2017 All rights reserved.


Product definition
MAG 8000 WCM - Visualization of the concept

Benefits of the smart built-in concept


ƒ Easy plug & play for retrofit
ƒ Integrated module
ƒ No compromises IP68 on MAG 8000
ƒ Wireless data logging function
ƒ Battery-operated – Rechargeable
system
ƒ Open analog inputs

Unrestricted © Siemens AG 2017 All rights reserved.


Agenda

⋅ Introduction
⋅ Working principle
people + products = success
⋅ Applications
⋅ Product Description
⋅ Basic Settings

SITRANS F M
MAG 8000

Unrestricted © Siemens AG 2017 All rights reserved.


Basic Settings
MAG 8000 WCM – Basic Information SMS

SIM Card Requirements

First time settings


Set the PIN code: 1000
Using a normal phone to change it.

SMS command syntax


Configuration;<Parameter 1>=<value>;<Parameter 2>=<value>;
Note: Every command ends with “;”

Email Account requirements:


In 2G version SMTP as POP 3, via 3G a standard SMTP or SMTPS with
encryption through SSL.

Unrestricted © Siemens AG 2017 All rights reserved.


MAG 8000 WCM - SMS commissioning settings

Step 1:
Send the SMS with the parameter and received the confirmation.

Configuration;P3=+451111111;
01/01/2013 12:00

Configuration;P3=+451111111;
123456H123 2013-01-01 12:00 Send
Configuration: OK

Step 2:
Test SMS functionality sending:

GET_BAT_CAP; Send
GET_MEASUREMENT_DATA;

Unrestricted © Siemens AG 2017 All rights reserved.


MAG 8000 WCM - SMS commissioning settings

Retrieved Information

Unrestricted © Siemens AG 2017 All rights reserved.


MAG 8000 WCM - SMS commissioning settings

SMS Alarms

Unrestricted © Siemens AG 2017 All rights reserved.


MAG 8000 WCM - SMS commissioning settings

Reset functions via SMS


The module offer different levels of security for delete
information:

The basic is press the push button for 20 sec (4 led


flashing) – This operation will delete only the logging
and transmission set up.

The medium is the alarm reset log, we recommend to


use this function periodically or when you received an
alarm to clear all the flags and get new events on the
same one.

The high level is the reset of the white list or MSISDN


(3 phone numbers allow to configure the module, P4,
P5 & P6). This will open the module for configuration
to any phone number as a brand new unit, reason why
the PIN code is required as a security code.

Unrestricted © Siemens AG 2017 All rights reserved.


MAG 8000 WCM - SMS commissioning settings

Simplify set up Android application

Unrestricted © Siemens AG 2017 All rights reserved.


MAG 8000 GSM WCM: GPRS Settings (internet).

Use Google or Wikipedia search: APN settings


For your correspondence country

The APN settings on the GSM/GPRS module


ensure two use cases:
1 Standard internet mobile communication:
Means use the normal mobile netwwork
- APN, User name/Password
Parameters: P10, P11, P12
2 Private mobile communication:
Means some big water companies own their
particular APN with a restrict access from external
users.
- APN plus DNS, Username/Password.
Parameters: P10, P11, P12 and P13
Unrestricted © Siemens AG 2017 All rights reserved.
MAG 8000 GSM WCM: GPRS Settings.

NETWORK INFORMATION
Company name N/A:
TDC in Denmark
SIM card telephone no N/A:
+45 99 00 11 00
SMS service center P3:
+45 40390999
APN (Access Point name) P10:
internet
SMTP EMAIL SETTINGS
Server Domain name P14:
GPRS access
send.one.com
Step 3: User name P15;
MAG8000_DK_MCA01@MAG8000.com
Send the Internet settings User password P16:
12345678
Configuration;P10=internet; MAG8000 E-mail address P17:
MAG8000_DK_MCA01@MAG8000.com
Configuration;P14=send.one.com; Recepient E-Mail address P18,P19,P20:
MAG8000_DK_MCA@MAG8000.com

Configuration;P15=MAG8000_DK_MCA01@MAG8000.com;
Configuration;P16=12345678;
Configuration;P17=MAG8000_DK_MCA01@MAG8000.com;
Configuration;P18=MAG8000_DK_MCA@MAG8000.com;
Unrestricted © Siemens AG 2017 All rights reserved.
MAG 8000 GSM WCM: GPRS Settings.

NETWORK INFORMATION
Company name N/A:
TDC in Denmark
SIM card telephone no N/A:
+45 99 00 11 00
SMS service center P3:
+45 40390999
APN (Access Point name) P10:
internet
SMTP EMAIL SETTINGS
Server Domain name P14:
Text file
send.one.com
User name P15;
MAG8000_DK_MCA01@MAG8000.com

Step 4: User password P16:


12345678

Test Email functionality sending: MAG8000 E-mail address P17:


MAG8000_DK_MCA01@MAG8000.com
Recepient E-Mail address P18,P19,P20:
TestEmail; MAG8000_DK_MCA@MAG8000.com

Unrestricted © Siemens AG 2017 All rights reserved.


MAG 8000 GSM WCM: FTP Settings.

NETWORK INFORMATION
Company name N/A:
TDC in Denmark
SIM card telephone no N/A:
+45 99 00 11 00
SMS service center P3:
+45 40390999
APN (Access Point name) P10:
internet
FTP SETTINGS
Server Domain name P43:
Cloud server
ftp.mag8000.com
User name P45;
Mag8000.com

Step 5: User password P46:


FTPMAG8000

Data delivering via FTP server: FTP working directory P84:


FTP

Configuration;P43=ftp.mag8000.com; FTP Port Nr. (990) Optional, P44:


E.g. 21

Configuration;P45=mag8000.com;
Configuration;P46=FTPMAG8000;
Configuration;P84=FTP;

Unrestricted © Siemens AG 2017 All rights reserved.


MAG 8000 GSM WCM: Collecting Data Settings.

LOGGER INFORMATION
Sample rate P55:
XX - Selected time base
Time units:
min, h.
Programed Transmission slot P56:
XX – Selected time base
Time units:
h, d, M (hours, day, month)
NOTE:
The exclusion of this value will give a
CSV file base of number of samples collected
before delivering.
(P55=1min; P56=15; ⇓ send every 15
collected data = 15min).

Step 6: Synchronization for collection P61:


This will be the time when the module
will start to collect data on the csv file.
Definition of the sample rate and data delivery: ONLY USE when P55 different to 1 min.

Configuration;P55=10min;
Configuration;P56=24h;
Configuration; P62=06:00;
IMPORTANT!
Synchronization of the clock is done via NTC server on version 3.09 only.

Unrestricted © Siemens AG 2017 All rights reserved.


MAG 8000 GSM WCM: Collecting Data Settings.

Text alarm

Step 7:
External alarm options:
Configuration;P53=1;
Configuration;P54=1;

0 = no alarm
4mA = alarm bit 16
20mA = alarm bit 15

Unrestricted © Siemens AG 2017 All rights reserved.


MAG 8000 GSM WCM: Email Example.

Easy view using any data sheet program !

Unrestricted © Siemens AG 2017 All rights reserved.


MAG 8000 GSM WCM: Qualification Certificated.

Email

For your more


valued asset!

Step 8:
Remote QC report:

GET_QC:1000; Send
demo@mag 8000.com;

Unrestricted © Siemens AG 2017 All rights reserved.


Thank you!
For your attention.

www.siemens.com/mag8000

Unrestricted © Siemens AG 2017 All rights reserved.


MCA / ISD Env
Thank you for your attention!

Luis Felipe Luna González


Flow Sales Specialist
PD PA PI FL

Av. Ejercito Nacional 350,


Col. Polanco V Sección,
Del. Miguel Hidalgo,
Ciudad de Mexico, C.P. 11560
México

Mobile: +52 (55) 6194 2078


E-mail:
luis.luna@siemens.com
siemens.com/coriolis

Unrestricted © Siemens AG 2017 All rights reserved.

Potrebbero piacerti anche