Sei sulla pagina 1di 4

(B) BILLS OF QUANTITIES FOR INTERNAL FIRE FIGHTING INSTALLATIONS

ITEM DESCRIPTION QTY. UNIT UNIT AMOUNT


NO. RATE US$

1.0. 25MM HOSE SYSTEM

Supply and install the following galvanized


pipes and fittings jointed with threaded fiitings

1 50mm dia. pipe 12 lgth 0.00 0.00

2 25mm ditto 3 lgth 0.00 0.00

3 50mm x 90O elbow 10 No 0.00 0.00

4 50mm equal tee 6 No 0.00 0.00

5 50 x 50 x 25mm reducing tee 5 No 0.00 0.00

6 25mm x 90O elbow 5 No 0.00 0.00

7 25mm dia globe stop valve 5 No 0.00 0.00

8 50mm screwed end cap 2 No 0.00 0.00

9 50mm dia. Automatic Air Vent 2 No 0.00 0.00

10 Swinging fire hosereels as MACRON


with automatically operated valve to the ff:-
Nozzle type - Jet
Nozzle size - 25mm
Nose length - 30m
Finish - Red 5 No 0.00 0.00

11 Other materials not listed but required to make


installations complete 1 Lot 0.00 0.00

Total Carried to Collection 0.00


ITEM DESCRIPTION QTY. UNIT UNIT AMOUNT
NO. RATE US$

2.0. PORTABLE FIRE EXTINGUISHERS

Supply and install the following:-

1 C02 fire extinguisher as MACRON


or approved equal.
Capacity: 5kg 12 No 0.00 0.00

2 Multi-purpose dry chemical fire


extinguisher as MACRON or equal
Capacity: 9kg 12 No 0.00 0.00

Total Carried to Collection 0.00

3.0. FIRE SUPPRESSION SYSTEM (SERVER ROOM)

SYSTEM HARDWARE, DETECTION & CONTROL

Supply and installation of the following :

1 Low Pressure 80LT. Gas Cylinder comprising 50KG


FM-200 gas agent, adapter, low pressure supervisory
switch, solenoid lead, press switch, actuator,
door caution plate etc. 2 No 0.00 0.00

2 Electric soleniod actuator complete with


cylinder valve CV 90 2 No 0.00 0.00

3 Maintenance Switch
4 No 0.00 0.00
4 Abort Switch
1 No 0.00 0.00
5 Ionization Detector
1 No 0.00 0.00
6 Optical photoelectric Detector
1 No 0.00 0.00
7 Pull Station
1 No 0.00 0.00
8 Strobe
1 No 0.00 0.00
9 Motorised Alarm Bell 6"
1 No 0.00 0.00
10 Discharge Hoses with check valves
1 No 0.00 0.00
11 Discharge Nozzle 25mm
2 No 0.00 0.00
12 Smoke / Heat Detectors
2 No 0.00 0.00
13 Deflector shield
4 No 0.00 0.00
14 Agent Release Control Panel
2 No 0.00 0.00
PIPEWORKS & ACCESSORIES
1 No 0.00 0.00
Supply and install the following galvanized schedule
40 pipes and fittings jointed with threaded fittings

15 Pipes and accessories

16 Electrical cables and accessories


1 Lot 0.00 0.00
17 Other materials not included but needed to
make installation complete. List them 1 Lot 0.00 0.00

Total Carried to Collection US$ 0.00

COLLECTION

1 25mm dia. HOSE SYSTEM 0.00

2 PORTABLE FIRE EXTINGUISHERS 0.00

3 FIRE SUPRESSION SYSTEM 0.00

4 FIRE FIGHTING INSTALLATION TO SUMMARY US$ 0.00

Potrebbero piacerti anche