Sei sulla pagina 1di 2

AL MUASER PETROLEUM SERVICES PVT LTD

CLIENT: INDIAN OIL CORPORATION LIMITED


DOCUMENT NO.
EPIL-IOCL-KV-REPL-ML-ITP-16
REV. NO. : 00 KASPL PIPELINE PROJECT

INSPECTION AND TEST PLAN FOR WELD REPAIR


Inspection By Verification by Documents to be submitted by
Sr. No. Activity Description AMPS IOCL AMPS

1 Weld Repair procedure selection and approval W A AMPS- IOCL-KASPL-ML-JP-16

2 Welder Qualification W W

3 Identification of weld W RM

4 Ensure weld Repair is allowed once W R

5 Removal of diposited material upto detection of defect W RM

6 PT of cut bevel to ensure complete difficiency is removed W RM

7 Ensuring cleaning of the repair area W RM

8 Pre-heat and welding of repair area W RM

9 Visual Inspection of welding W RM

10 RT of butt welds W FR

Legend
W : Witness. FR : Film review
RM : Random.
R : Review Documents.
Prepared by AMPS Reviewed & Approved by IOCL Reviewed & Approved by IOCL
AL MUASER PETROLEUM SERVICES PVT LTD

DOCUMENT NO. CLIENT: INDIAN OIL CORPORATION LIMITED


AMPS-IOCL-KASPL-ML-
IR-16, REV. NO. : 00 KASPL PIPELINE PROJECT

INSPECTION REPORT OF WELD REPAIR


SPREAD: FROM TO SEC: DATE
S. No KM/ Joint. No. Segment WPS DPT Welder No. Visual Exam. REMARKS

REMARKS/FIELD PROBLEMS, IF ANY

AMPS IOCL
SIGN SIGN
NAME NAME
DATE DATE