Contents page
1. Introduction ------------------------------ 2
2. Specification ------------------------------ 3
3. Component -------------------------------- 4
4. System Configuration ------------------ 5
5. Principle of operation ------------------ 6
6. Explanation of equipment ------------ 7
7. Speed test ---------------------------------- 18
8. System Block diagram ----------------- 20
9. Connection diagram --------------------- 21
10. Circuit diagram --------------------------- 23
11. PCB unit view ----------------------------- 26
12. Outline &. Setting drawing ----------- 31
13. Spare parts list --------------------------- 41/41
JLN-205 family
2/41
1. Introduction
• Corresponded to the new IMO [MED Certificate number: QQ-MED-39/04-01]
MSC.96(72)Rev:IMO A.824(19), IMO A.694(17), IEC61023:1999
IEC60945:2002, IEC61162-1:2000
• Corresponded to the JG [JG Certificate number: No.4690]
• Measured without the bubble influence at high-speed.
• High performance, high quality, and low price
Signal Processor
Signal Distributor
2. Specifications
Items Specifications
Operating System Dual beam pulse Doppler
Frequency 2MHz (measurement to WT Speed)
Speed measure range Fore/Aft. -10 to +40kn
Run distance range 0 to 99999.99nm
Depth range Greater than 3m (below hull bottom)
Speed accuracy ±1% or ±0.1kn whichever value is greater
Distance accuracy ±1% or ±0.1nm in each hour whichever value is greater
Display XX.X(X) digital display of 3 digits (part 4 digits)
Speed unit: kn or m/s It is possible to switch.
Analog display (option): kn
IEC61162-1 input GPS (for GPS speed display) Either of $--RMC, $--RMA, $--VTG,
(NMEA0183) V2.0 or more
IEC61162-1 output Speed, distance data output $VDVBW, and $VDVLW 8
(NMEA0183) V2.3 (It is possible to switch to V1.5 ) circuits
Other output Output for analog display (-2 to +10V) 2 cir.
200pulse/nm opto-coupler output (30VDC or less, 50mA) 4 cir.
200pulse/nm relay output (30VDC or less, 1A) 1 cir.
Output for NWW-65 slave display 2 cir.
Output for NWW-7 distance counter 1 cir.
Output for NWW-5/16 remote display 1 cir.
Output for online maintenance 1 cir.
Contact output for Power fail alarm 1 cir.
Power supply 100/110/115/220/230VAC
±10%, 50/60Hz, 1φ
Power consumption 100VA or less
Operating temp. range -15 to +55℃
Operating hum. range +40℃, 93%
3. Component
Standard equipment
Description Model No. Qty. Mass Waterproof Remarks
Main Display NWW-65A 1 0.8kg IPX5 A: Desk-top type
-65B B: Flush mount type
Signal NQA-4288 1 6kg IPX2
Distributor
Signal NJC-25 1 6kg IPX5
Processor
Transducer NKF-547 1 17kg IPX8 Flush mount type
With cable 30m
Spare Parts 7ZXBS0020 1 -- --
Instruction 7ZPBS2803A 1 -- -- English
Manual
Option equipment
Description Model No. Qty. Mass Remarks
Slave display NWW-65S 2 0.8kg SA: Desk-top type
SB: Flush mount type
Analog display NWW-24 2 6.5kg Flush mount type
NWW-25 7kg Wall mount type
NWW-26 2.5kg Panel mount type
Remote display NWW-5 1 1.5kg 1 axis, Flush mount type
Remote display NWW-16 2.5kg 1 axis + Distance,Flush mount
Distance NWW-7 1 0.8kg Flush mount type
counter Max. 9999.99nm
Dimmer unit NCM-227D ― 0.5kg For main/slave display
NCM-329 ― 0.5kg For analog display
NCM-227 ― 0.5kg For remote display
Junction box NQD-2025 1 0.5kg NWW-65/S←→NQA-4288 extension
Transducer NKF-531E 1 48kg Gate valve type
With cable 25m
Transducer CFT-022B 1 - For NKF-547
element (25, 30, 40m in length of cable)
CFT-023B 1 - For NKF-531E
(25m in length of cable)
Flush MPTG30432 - - For main/slave display
mounting kit
Instruction 7ZPBS1804 - - Japanese
manual
Technical 7ZPBS3802 - - Japanese
manual 7ZPBS4802 - - English
5/41
4. System Configuration
[Standard] [Option]
3.9” LCD
NWW-
Main display Dimmer unit Slave display 24/25
Special cable NCM-227D
JRC supply NWW-65 NWW-65S
Analog
Junction box display
5m Max. NQD-2025
Junction box
Signal distributor 100m Max. NQD-2025
Junction box
NQA-4288 NCM-329
Ship’s main
Dimmer unit
NCM-227 Remote display
NWW-5
Data input
(GPS)
Distance
counter
NWW-7
NWW-16
Dimmer unit
NCM-329
YARD
500m Max. NWW-26
Data output
IEC61162-1
General-purpose wire 200pulse/nm Analog
TTYC-4S Online mainte display
Power fail
Signal processor
NJC-25
Special cable
JRC supply
30m Max.
5. Principle of operation
-1. Water Tracking speed (WT)
This product transmits ultrasound waves obliquely into the sea water and receives the water
echo reflection from the plankton and other suspended solids in the water.
V: Ship’s speed
θ: Angle of dip
Seabed
The signal receiving frequency, "f1", is determined by the amount of Doppler shifting of the transmitting
frequency, "f0", according to the particular speed of the ship.
During actual operation, ultrasound beams are emitted in two directions on the line from the bow to the
stern. The number of the transducer cable corresponds to the direction of each beam.
Additionally, there is a lined of the thermistor, too.
c Fore beam
Angle of dip
75°
e After beam c e
The water speed of the ship (WT) is computed from the received signals of the log reflections in the two
directions.
6. Explanation of equipment
-1. Main display NWW-65
P1 Dip sw
MODE
S1 1234 CONT
Main power supply DIM
・As for the standby power supply, DC12V is always supplied. When [PWR] switch is
pushed long times, the power of the Signal distributor is turned on. And, the power is
supplied to the entire system. Main power supply DC12V is supplied to the Main display.
When [PWR] and [CLR] are pushed at the same time, the power turns off. And, the power
of the entire system turn off.
The state of ON/OFF is maintained in CBL-109. Therefore, even if the blackout is done
while turned on, the power automatically stands up.
* Please refer to the power supply system in next chapter explanation.
・Dip switch: Function of S1 Standard setting
Mean Dimmer control Main/Slave Dimmer Main/Internal: 1100← Factory
No. c d e f Main/External: 0001 setting
ON Internal Slave External Slave/Internal: 1110
OFF External Main Internal Slave/External: 0011
・Slave display connection
It is displayed under an initial screen when setting it to the Slave display as [Slave].
(It is [Main] in the Main display. )
A set content is not memorized though the setting that relates to display can be changed.
When starting, it becomes a content of the Main display set.
The main power input and the standby power input are connected with parallel.
Use Junction Box
Slave display
WHT
1 1
2 2
GRY
BLU
NWW-65S DATA2
3 3 Bright Gray cable
4 4
BRN 7P P2
YEL
Dimmer unit 5
GRN DCPWR/DATA
6
Parallel connect RED
7 6P P1
8
From Signal BRN
+12V 9
distributor YEL
0V 10 GRN
DT+ 11 RED
DT- 12 WHT
13 BLK
14
S
15 Dark Gray cable
CQD-1988
Terminal Board
Ship’s main TB501 Fuse 6.3A
TB501
AC100V Power switch 3.15A AC in
+12V
S501
AC110V 3.15A 12V out
AC115V Standby 0.5A 24V in
AC220V power supply
0.5A EL out
AC230V
Terminal
TB514A
TB514B
TB515A
TB515B
TB519A
TB519B
TB511
TB512
TB513
TB516
TB517
TB518
+12V
Main power
supply
Dip switch
J531 S511 S512
12345678 12345678
S501 to NJC-25
+12V +12V 3.15A
standby main
○ ○ ●
to NWW-65
NQA-4288 TB514A
WHT
Main display
Signal Distributor 1
2
GRY
NWW-65 DATA2
BLU
3 Bright Gray cable
4
BRN 7P P2
YEL
5
GRN DCPWR/DATA
6
RED
7 6P P1
8
TB513 TB514B
BRN
1 1
YEL
2 2
GRN
3 3
RED
4 4
1+ WHT
5 5
1- BLK
6 6
2+ Dark Gray cable
7 7
8 2- 8
10kΩ
1+
1
1-
2
2+ 3
2- 4
NCM-227D
Dimmer unit
Connect the dimmer unit to Junction box when you use Junction box.
Connect the dimmer unit by using Junction box when you use an external dimmer
at the Slave display.
1+ 1+ 1+
1 analog 1
2 1- 2 1-
1- 1kΩ 2+
3 3
4 AC100V 4 2+
NCM-227 2- 5 2- EL
Dimmer unit
Analog display
NCM-329 50kΩ
Dimmer unit
・Input circuits
GPS input (TB513 -①②) ・・・ For GPS speed display
+ 200Ω
● to internal circuit
IEC61162-1
(NMEA)
●
-
System Alarm ACK in (TB519A-④⑤)・・・ System alarm release ← now unused it.
contact or TTL
+ S511
440Ω
● ● ●
To internal
Contact input: ①②ON
○
or circuit TTL input: ①②OFF
○
- ●
11/41
・Output circuits
IEC61162-1 output (TB515A -①②③④, ⑤⑥, and ⑦ ⑧) ・・・ Digital interface
(NMEA0183) (TB515B-①②、③④、⑤⑥、⑦⑧)
4 channels of TB515A
●
+ 4 channels of TB515B,
RS-422 standard output V1.5 or V2.3(default)
- It is possible to set it
individually.
○
Maximum rating 0-2000pulse/nm (0 standards) can be set.
○
30V,1A (100 steps)
NO ‘0’ means output Off
Power Fail Alarm relay point of contact output (TB518 -①②③) ・・・ Power fail output
NC
Maximum rating
○ COM
●
○
30V,2A
NO
System Alarm relay point of contact output (TB519A -①②③) ・・・ ← now unused
NC
Maximum rating
○ COM
●
○
30V,2A
NO
12/41
TB2 8 8 8 8 8 8 8 8
to transducer
Dip switch
S01 S104 S103 S102 S101
12345678 12345678 12345678 12345678 12345678
S200
Signal Processor
to signal distributor TB1
P101
3 TB100 Fuse
2 Tap switch 6.3A AC input
1 2A EL output
Program writing
Fuse
2A
Power
transformer CMN-686
2M TRX unit
・The tap in the power supply part is changed according to the voltage of ship’s main.
Confirm Check box of the back side of the lid.
Ship’s main Tap change of TB11
100V
Low
110V ① ⇔ ②
side
115V
220V High ←Factory
① ⇔ ③
230V side setting
Always turn on S200 usually.
・When the program update is done, P101 is connected with PC. It loads a program from PC.
Turn on ⑦⑧ of S01.
Turn off S01⑦⑧ after ending the update.
S02 is a reset switch.
・When the power is turned on, the lamp test and version information are displayed
in monitor LED.
The first about 5 sec. ………… LED off
About 5 sec. afterwards. …… 【88888888】 ← lamp test
About 20 sec. afterwards. ……【1.00-.1d】 ← program version information *
*:When S101 ① is set to "ON", volume No. is displayed.
Character A B C D E F G H I J K L M N O P Q R S
Display
Character T U V W X Y Z 0 1 2 3 4 5 6 7 8 9 - .
Display
13/41
Bottom:5m
TP452
TP454 2nd. Echo of bottom
noise
0.65V
GND level
TP6
ON/OFF CMN-686
AC control Transmitter
● ●
26V DC40V
Protection
circuit
This power circuit is controlled so that the transmission B voltage may become +30V.
After about 25 seconds pass from power ON, the transmission is begun.
When abnormality (over-voltage of the transmission output, over-current of power FET)
in the transmitter is detected, the transmission pulse is stopped in the protection circuit.
14/41
・Dip switch
No Dip switch default Item Function 1:ON, 0:OFF
1 S01 ① 0 ――― (unused)
2 ② 0 ――― (unused)
3 ③ 0 ――― (unused)
4 ④ 0 ――― (unused)
5 ⑤ 0 ――― (unused)
6 ⑥ 0 ――― (unused)
7 ⑦ 0 ――― 00:usually, 11:Program update
8 ⑧ 0 ―――
9 S101 ① 0 VOL No. 0:usually, 1:Software volume No.
10 ② 0 ――― (unused)
11 ③ 0 WT processing 0:usually
12 ④ 0 ――― (unused)
13 ⑤ 0 ――― (unused)
14 ⑥ 0 ――― (unused)
15 ⑦ 0 WT noise 0:Usually(auto), 1:Manual(-000000=0.0V)
16 ⑧ 0 WT noise polarity 0:(reference)+(set value), 1:(reference)-(set value)
17 S102 ① 0 WT noise 000000: Usually
18 ② 0 Set value
19 ③ 0
20 ④ 0
21 ⑤ 0
22 ⑥ 0
23 ⑦ 0 ――― (unused)
24 ⑧ 0 Maintenance 0: Usually
25 S103 ① 0 ――― Internal use (Do not change the setting. )
26 ② 0 ――― Internal use (Do not change the setting. )
27 ③ 0 ――― Internal use (Do not change the setting. )
28 ④ 0 COM1 Monitoring Data Output setting 0:Usually, output:1
29 ⑤ 0 Local correction 0: Usually
30 ⑥ 0 ――― Internal use (Do not change the setting. )
31 ⑦ 0 ――― Internal use (Do not change the setting. )
32 ⑧ 0 ――― Internal use (Do not change the setting. )
33 S104 ① * Monitor display 0000: Internal clock (1/10 sec)
However, 1000:
0100: Quantity of 2MHz data sampling
In case of
1100:
S104 ⑤ -⑧ 0010: Calculation mode
34 ② * =“0000“ 1010: Distance Odo[nm]
effective 0110: Distance Trip[nm]
1110:
0001:
35 * 1001:
③
0101:
1101:
0011: WT speed [kn]
1011: 3.3V Voltage [V]
36 ④ * 0111:
1111:
37 ⑤ 0 WT processing 00:Usually
38 ⑥ 0
39 ⑦ 0 WT filter 00:Usually
40 ⑧ 0
15/41
Bow
②Thermistor
Bow mark
(White paint)
①beam ③beam
Fore ① ● ● Z0 ≈ 50Ω
beam ② ●
②
Thermistor
③
Thermistor ● ● 2.5kΩ/25℃
④
③ ●
After ⑤ ● ● Z0 ≈ 50Ω
beam ⑥ ●
●
・Kind of transducer
Usage Transducer type Remarks
for NKF-547 CFT-022B-30 30m, for production
CFT-022B-01 40m, for maintenance
for NKF-531E CFT-023B-01 40m, for maintenance
16/41
NJC-25
Unit Part No Function Status
CDC-1228 CD44 DOWN data input Blink (light: data input)
CD45 UP data output Blink (light: data output)
CD46 Dsub-9 output Blink (light: data output)
CD47 Dsub-9 input (Blink, PC update data input)
CD48 TXG transmitting gate Blink (PRR:1sec. Light:5 times)
CD49 PROTECT Not Lit (light: abnormal TX)
CD150 +3.3V (for CPU) Lighting always
CD151 +15V (for OP-AMP) Lighting always
CD152 –15V (for OP-AMP) Lighting always
CD153 +30V (for transmission) Lighting always
CD154 +2.5V (for FPGA) Lighting always
CD155 +5V (for data output driver) Lighting always
CMN-686 CD401 +15V input Lighting always
CD402 +8V (for analogue) Lighting always
CD403 +5V (for logic) Lighting always
CD404 +30V (for transmission) Lighting always
CD426 Transmission output Blink (PRR:1sec. Light:5 times)
17/41
NQA-4288
Unit Part No Function Status
CQD-1988 TP501 + 12V + 12V±1.5V
TP502 + 35V + 35V±4V
TP503 + 5V + 5V±0.2V
TP504 + 3.3V + 3.3V±0.15V
TP505 + 1.5V + 1.5V±0.1V
TP506 – 12V -12V±1.3V
TP507 ――― (Unused)
TP510 CPU RESET “H" Level
TP511 WDT “H" Level
TP512 (reserve) ―――
TP521 GND GND
NJC-25
Unit Part No Function Status
CDC-1228 TP1 + 3.3V + 3.3V±0.15V
TP2 + 15V + 15V±0.7V
TP3 -15V -15V±0.7V
TP4 + 30V + 30V±6V
TP5 GND GND
TP6 TXG 1s
100ms 2 ms
TP6
TP453 Aft_Freq (Aft Frequency) (TP451 is similar)
TP454 Aft_Ampl (Aft Amplitude ) (TP452 is similar)
18/41
7. Speed Test
After installation, the indicated speed must be calibrated in comparison with corresponding true
speed to make the best use of the excellent features of this Doppler Log and effectively utilize it.
For the speed calibration, in usual, the ship is run between Mile Post to obtain a calibrated value
from the turnaround time. Measured values in this time must be accurately recorded on a
Doppler Log speed test sheet and it must be stored. If the equipment faults some other day and
the circuit board are replaced, this record will serve for accurate adjustment.
Before running between the Mile Post, the ship must be provisionally run enough to reduce the
speed variation during passing between the posts, as possible. In addition the ship must be also
sailed correctly in directions indicated by the Mile Post. When the effects of both ocean current
and wind can be regarded to be constant in time during test, the ship may go and return once for
measurement. When these effects are, however, considered to very in time, it preferably goes and
returns two times. If the difference between measured values in the same direction exceeds 0.5
knot, the measurement must be repeated.
-1. For the Mile Post running test, the ship usually goes and returns four times at 1/4, 2/4, 3/4
and 4/4 of the main engine’s rating.
-2, The rotation frequency of the propellers and course should be made constant at a point,
at least, one nautical mile away from the first Mile Post, before entering the test area,
and kept constant until the test ends.
-3. The instant ship passes by Point A of Figure below, depress both a stopwatch 1 and
reset button of the Main Display of this equipment.
-4. The instant the distance counter indicates a reading of 0.01nm, depress another stopwatch 2.
-5. The instant the ship passes by point B, again depress the stopwatch 1 to find a time t1
required for running between the two points, the Mile Post.
-6. The instant the distance counter indicates a value of 1.01nm, depress the stopwatch 2 to
obtain a time t2 required for running 1.00nm of the Doppler Log.
Note: Steps -5 and -6 may be reversed in time.
-7. Calculate the true and log speeds from above measured times.
a
A point B point
B point A point
NQA-4288
NCM-227D 250V-TTYCS-4 (YARD Max. 100m) 250V-TTYCS-4
Dimmer Unit
CFQ-7222
CFQ-7221
Signal Distributor
(option) 250V-TTYCS-4 (YARD Max. 100m) NCM-329
Dimmer Unit
(option)
Max. 15m)
CFQ-7221 (JRC 5m)
TTYCS-4
DPU UNIT
POWER CONTROL
24/41
TERMINAL BOARD
25/41
2M_TRX UNIT
SIGNAL PROCESSOR
26/41
G
27/41
SET PER
SHIP No. SPARE PARTS LIST FOR USE
VESSEL
MODEL JLN-205
Doppler Log
QUANTITY REMARKS
ITEM NEME OF PART OUTLINE WORKING SUB
No. (Dimension in m/m) DESCRIPTION
SPARE MARK OF
PER PER JRC CORD No. BOX No.
SET VESS
20
φ5.2
MF51NR0.5
1 1 2
Fuse 5ZFAA00147
20 φ5.2
250V A TSC2A
2 3 2
Fuse 5ZFCA00118
20
φ5.2
215 3.15
3 1 2
Fuse 5ZFAP00101
20
φ5.2
ULT SC 6.3AN1
4 1 2
Fuse 5ZFCA00034
Since 1915
EDITION 3
June. 2008
JRC
CODE NO. 7ZPBS4802
Made in JAPAN