Sei sulla pagina 1di 43

0/41

JLN-205
Doppler Log

Technical Service Manual


1st. edition : 20 . Oct. ’06
3rd. : 02. June. ‘08

Contents page
1. Introduction ------------------------------ 2
2. Specification ------------------------------ 3
3. Component -------------------------------- 4
4. System Configuration ------------------ 5
5. Principle of operation ------------------ 6
6. Explanation of equipment ------------ 7
7. Speed test ---------------------------------- 18
8. System Block diagram ----------------- 20
9. Connection diagram --------------------- 21
10. Circuit diagram --------------------------- 23
11. PCB unit view ----------------------------- 26
12. Outline &. Setting drawing ----------- 31
13. Spare parts list --------------------------- 41/41

MARINE ELECTRONICS DIVISION


1/41

JLN-205 family
2/41

1. Introduction
• Corresponded to the new IMO [MED Certificate number: QQ-MED-39/04-01]
MSC.96(72)Rev:IMO A.824(19), IMO A.694(17), IEC61023:1999
IEC60945:2002, IEC61162-1:2000
• Corresponded to the JG [JG Certificate number: No.4690]
• Measured without the bubble influence at high-speed.
• High performance, high quality, and low price

-1. Correspondence of bubble influence


The transducer was made small. As a result, we can install the transducer in Bow.
Diameters are 90% smaller than the past. (φ150→φ135)
-2. WT speed measurement at 3m depth
The velocity of WT is measured by using high frequency (2MHz) based on
the reflection signal between about 2-3m under the bottom of a ship.
-3. Improvement of signal processing speed
A newly Doppler frequency detector circuit was developed.
As a result, the measurement by very shallow depth became possible.
Speed of signal detector: 3 × speed (High performance FPGA adoption)
Processing speed of data: 5 × speed (High performance CPU adoption)
-4. Improvement of visibility
The large size character font is adopted, and the visibility has improved greatly.
The maximum font size: 4cm×2cm (ex. of the other companies: 2.3×1cm)
-5. Abundant options
All remote indicators of an old model can be connected.
-6. The special cable of the JRC supplied no use.
The signal processor install in the Bow, and the general-purpose wire is used by
several 100m to the signal distributor (500m or less). The influence of noise is not
received easily so far because the transducer cable was assumed to be 30m,
and a steady velocity of the ship is possible.
Display

Signal Processor
Signal Distributor

Transducer General-purpose wire (Dock yard)


Flush or Gate Valve TTYC-4S

2MHz ultrasonic beams

Image chart of new Doppler log


3/41

2. Specifications
Items Specifications
Operating System Dual beam pulse Doppler
Frequency 2MHz (measurement to WT Speed)
Speed measure range Fore/Aft. -10 to +40kn
Run distance range 0 to 99999.99nm
Depth range Greater than 3m (below hull bottom)
Speed accuracy ±1% or ±0.1kn whichever value is greater
Distance accuracy ±1% or ±0.1nm in each hour whichever value is greater
Display XX.X(X) digital display of 3 digits (part 4 digits)
Speed unit: kn or m/s It is possible to switch.
Analog display (option): kn
IEC61162-1 input GPS (for GPS speed display) Either of $--RMC, $--RMA, $--VTG,
(NMEA0183) V2.0 or more
IEC61162-1 output Speed, distance data output $VDVBW, and $VDVLW 8
(NMEA0183) V2.3 (It is possible to switch to V1.5 ) circuits
Other output Output for analog display (-2 to +10V) 2 cir.
200pulse/nm opto-coupler output (30VDC or less, 50mA) 4 cir.
200pulse/nm relay output (30VDC or less, 1A) 1 cir.
Output for NWW-65 slave display 2 cir.
Output for NWW-7 distance counter 1 cir.
Output for NWW-5/16 remote display 1 cir.
Output for online maintenance 1 cir.
Contact output for Power fail alarm 1 cir.
Power supply 100/110/115/220/230VAC
±10%, 50/60Hz, 1φ
Power consumption 100VA or less
Operating temp. range -15 to +55℃
Operating hum. range +40℃, 93%

The other companies specification comparison


Maker Furuno Consilium JRC
Model DS-80 SAL R1 JLN-202 JLN-628 JLN-550 JLN-205
Method Pulse dopp Pulse Pulse dopp Pulse dopp Pulse dopp Pulse dopp
Detect ? Coriration zero cross, zero cross, zero cross, zero cross,
PLL Rate Rate Rate
Freque 1MHz 3.8/4.2MHz 2MHz 240kHz BT:240kHz 2MHz
ncy WT:2MHz
BT --------- --------- --------- 250m 2 to 250m ---------
WT 3m 0.11m 2 to 3m 3 to 20m 2 to 3m 2 to 3m
Speed -10 to 40kn ±50kn ±30kn -10 to 30kn -10 to 40kn -10 to 40kn
Trans φ80 φ50 φ60 450×180 φ196 φ60
ducer
Exten TTYCY-3S --------- M-933 --------- TTYC-7S TTYC-4S
sion
Units 4 4 3 3 4 4
Display 4.5” LCD LED LED 10” CRT LED 4” LCD
Others Production 3 axes:ROT
stoppage Underwater
connector
4/41

3. Component
Standard equipment
Description Model No. Qty. Mass Waterproof Remarks
Main Display NWW-65A 1 0.8kg IPX5 A: Desk-top type
-65B B: Flush mount type
Signal NQA-4288 1 6kg IPX2
Distributor
Signal NJC-25 1 6kg IPX5
Processor
Transducer NKF-547 1 17kg IPX8 Flush mount type
With cable 30m
Spare Parts 7ZXBS0020 1 -- --
Instruction 7ZPBS2803A 1 -- -- English
Manual

Option equipment
Description Model No. Qty. Mass Remarks
Slave display NWW-65S 2 0.8kg SA: Desk-top type
SB: Flush mount type
Analog display NWW-24 2 6.5kg Flush mount type
NWW-25 7kg Wall mount type
NWW-26 2.5kg Panel mount type
Remote display NWW-5 1 1.5kg 1 axis, Flush mount type
Remote display NWW-16 2.5kg 1 axis + Distance,Flush mount
Distance NWW-7 1 0.8kg Flush mount type
counter Max. 9999.99nm
Dimmer unit NCM-227D ― 0.5kg For main/slave display
NCM-329 ― 0.5kg For analog display
NCM-227 ― 0.5kg For remote display
Junction box NQD-2025 1 0.5kg NWW-65/S←→NQA-4288 extension
Transducer NKF-531E 1 48kg Gate valve type
With cable 25m
Transducer CFT-022B 1 - For NKF-547
element (25, 30, 40m in length of cable)
CFT-023B 1 - For NKF-531E
(25m in length of cable)
Flush MPTG30432 - - For main/slave display
mounting kit
Instruction 7ZPBS1804 - - Japanese
manual
Technical 7ZPBS3802 - - Japanese
manual 7ZPBS4802 - - English
5/41

4. System Configuration

[Standard] [Option]
3.9” LCD
NWW-
Main display Dimmer unit Slave display 24/25
Special cable NCM-227D
JRC supply NWW-65 NWW-65S
Analog
Junction box display

5m Max. NQD-2025

Junction box
Signal distributor 100m Max. NQD-2025
Junction box
NQA-4288 NCM-329
Ship’s main
Dimmer unit
NCM-227 Remote display
NWW-5
Data input
(GPS)
Distance
counter
NWW-7

NWW-16
Dimmer unit
NCM-329
YARD
500m Max. NWW-26
Data output
IEC61162-1
General-purpose wire 200pulse/nm Analog
TTYC-4S Online mainte display
Power fail

Signal processor

NJC-25

Special cable
JRC supply

30m Max.

Either one is installed.


Gate valve
Transducer Transducer
NKF-547 NKF-531E
6/41

5. Principle of operation
-1. Water Tracking speed (WT)
This product transmits ultrasound waves obliquely into the sea water and receives the water
echo reflection from the plankton and other suspended solids in the water.

V: Ship’s speed

θ: Angle of dip

Water echo reflection Plankton and suspended solids

Seabed

The signal receiving frequency, "f1", is determined by the amount of Doppler shifting of the transmitting
frequency, "f0", according to the particular speed of the ship.

2 × f 0 × V × cosθ C: Sound velocity (1,500 m/S)


f1 = f 0 +
C
The ship's speed, V, can therefore be inversely calculated by measuring the receiving frequency, "f1".

During actual operation, ultrasound beams are emitted in two directions on the line from the bow to the
stern. The number of the transducer cable corresponds to the direction of each beam.
Additionally, there is a lined of the thermistor, too.

c Fore beam

Angle of dip
75°

e After beam c e

The water speed of the ship (WT) is computed from the received signals of the log reflections in the two
directions.

-2. GPS-Based Speed of the Ship


GPS speed (SOG) can be displayed by connecting GPS.

Necessary sentence for GPS-Based Speed display


GPS : $**RMC, or $**VTG, or $**RMA

(It is necessary to input it more than one sentence.)


7/41

6. Explanation of equipment
-1. Main display NWW-65

to Signal distributor CBL-109 CML-418L


Power control unit DPU circuit
P2 3.9“ LCD
Standby power supply
Fuse ROM:IC102
/Remote
2A
/Dimmer (DC12V input protection)
PUSH

P1 Dip sw
MODE
S1 1234 CONT
Main power supply DIM

/data CLR PWR


OFF OFF

・As for the standby power supply, DC12V is always supplied. When [PWR] switch is
pushed long times, the power of the Signal distributor is turned on. And, the power is
supplied to the entire system. Main power supply DC12V is supplied to the Main display.
When [PWR] and [CLR] are pushed at the same time, the power turns off. And, the power
of the entire system turn off.
The state of ON/OFF is maintained in CBL-109. Therefore, even if the blackout is done
while turned on, the power automatically stands up.
* Please refer to the power supply system in next chapter explanation.
・Dip switch: Function of S1 Standard setting
Mean Dimmer control Main/Slave Dimmer Main/Internal: 1100← Factory
No. c d e f Main/External: 0001 setting
ON Internal Slave External Slave/Internal: 1110
OFF External Main Internal Slave/External: 0011
・Slave display connection
It is displayed under an initial screen when setting it to the Slave display as [Slave].
(It is [Main] in the Main display. )
A set content is not memorized though the setting that relates to display can be changed.
When starting, it becomes a content of the Main display set.
The main power input and the standby power input are connected with parallel.
Use Junction Box
Slave display
WHT
1 1
2 2
GRY
BLU
NWW-65S DATA2
3 3 Bright Gray cable
4 4
BRN 7P P2
YEL
Dimmer unit 5
GRN DCPWR/DATA

Parallel connect RED
7 6P P1

From Signal BRN
+12V 9
distributor YEL
0V 10 GRN
DT+ 11 RED
DT- 12 WHT
13 BLK
14

15 Dark Gray cable

・External dimmer connection(Refer to the above figure. )


It is displayed under an initial screen when setting it to an external dimmer as [Ext].
(It is [Int] internally. )
・Program version
The program version is displayed under an initial screen for about 8 sec.
Example: R.1.00
The Volume No. is displayed under the screen when setting it to a detail setting screen.
Example: V.10.10S
8/41

Detailed menu list


No Item Menu Setting default Unit Function
1 Alarm Alarm Off On ― On/Off for warning sound Those are the
usual menu
2 Click Click Off On ― On/Off for operating sound
setting item.
3 WT/GPS Mode WT GPS ― Display mode of vessel speed
GPS receiver is necessary It is possible to
4 Smooth Damping 0 1 0 [S] Average time: 10 to 240sec set from either
5 HiSpeed Hi 00.0 [kn] Upper speed alarm: 0 to 40kn menu.
‘0.00’means alarm Off
6 LowSpeed Low 00.0 [kn] Lower speed alarm: 0 to 40kn
‘0.00’means alarm Off
7 Adjust Correct +00.0 [%] Speed correction: -50.0 to +99.9%
‘+’means the display speed increases
8 NMEA1 NMEA1 1.5 2.3 ― Output Version of IEC61162-1:2000
NMEA 1 to 4
9 NMEA2 NMEA2 1.5 2.3 ― Output Version of IEC61162-1:2000
NMEA 5 to 8
10 Puls1 Puls1 02 ×100 Pulse rate of output: 0 to 20×100P/nm
LOG 1, 2
11 Puls2 Puls2 02 ×100 Pulse rate of output: 0 to 20×100P/nm
LOG 3, 4
12 Puls3 Puls3 00 ×100 Pulse rate of output: 0 to 20×100P/nm
LOG Relay (‘00’means output Off)
13 Scale Analog 30 [kn] Scale adjust of Analog display: 10 to 40kn
14 MF-NO FS2-MFNO 100 ― Do not change the set value.
15 MF-MI FS2-MFMI 025 ―
16 MF-WD FS2-MFWD 015 ―
17 LE-NO FS2-LENO 005 ―
18 LE-WD FS2-LEWD 094 ―
19 AVG FS2-WTAVG 120 ―
20 Odo - > Odo ReSet ― This resets
PUSH
the Total distance.
Push for long time. It returns by .
CLR
OFF

After power is On, it is effective only 1 minute.


21 ReSet Master ReSet ― This returns each menu setting to the default
value.
Total distance
PUSH
is not reset by this operation.
Push for a long time. It returns by CLR
OFF .
Execute this operation after completing
equipment.
22 Txoff TX On Off ― When turned Off transmission stops.
It returns On by turning on power again.
Use On normally.
23 Dummy Dummy Off 0 18 [kn] The dummy speed is displayed except when turned Off.
It changes
PUSH
with 18, 36, 40, -5, 18kn whenever
the is pushed. The external output is same.
The transmission is stopped when the dummy is
displayed.
It returns Off by turning the power on again.
Use On normally.
9/41

-2. Signal Distributor NQA-4288

CQD-1988
Terminal Board
Ship’s main TB501 Fuse 6.3A

TB501
AC100V Power switch 3.15A AC in
+12V

S501
AC110V 3.15A 12V out
AC115V Standby 0.5A 24V in
AC220V power supply
0.5A EL out
AC230V
Terminal

TB514A

TB514B

TB515A

TB515B

TB519A

TB519B
TB511

TB512

TB513

TB516

TB517

TB518
+12V
Main power
supply
Dip switch
J531 S511 S512
12345678 12345678

Program writing All usually “00000000"

・Power supply system


The all equipment is supplied power by the Signal distributor.
The device corresponds to AC100-230V of the power supply.
(Attention. NJC-25 is necessary to change in the tap. )
Note that the standby power supply in PCB unit is always energized.

Ship’s main 3.15A 6.3A


○ ○ ○ ○ ● ○ ○ ●

S501 to NJC-25
+12V +12V 3.15A
standby main
○ ○ ●

to NWW-65

Remote display power


0.5A
○ ○
Analog display EL
Always turn on S501 usually.
・EL power supply for analog display
The voltage of EL is made from the NJC-25. It is output from 1-2 and 5-6 of TB512.
Ship’s main : 220V → step down → EL power : 100V
・Update of program
Connect the serial communications cable to J531 (Dsub-9 pin).
Loads a program from the personal computer (PC).
When the program is updated, ⑦⑧ of S511 and ① of S512 are turned on.
Return it to turning off after it loads it.
S551 is a reset switch.
The volume No. of program can be confirmed on PC.
Puts the state of operation usually.
Confirm the data output from J531 by using the hyper terminal of the PC.
The following data is the volume No. (19200bps, 8bit, parity no, stop 1)
(example) &S_VER,Sig,10.11cH1,・・・・・・ ←Volume No. of NJC-25
&S_VER,Dis,10.12nH1,・・・・・・ ←Volume No. of NQA-4288
10/41

・External dimmer connection of main display at minimum composition

NQA-4288 TB514A
WHT
Main display
Signal Distributor 1
2
GRY
NWW-65 DATA2
BLU
3 Bright Gray cable
4
BRN 7P P2
YEL
5
GRN DCPWR/DATA
6
RED
7 6P P1
8

TB513 TB514B
BRN
1 1
YEL
2 2
GRN
3 3
RED
4 4
1+ WHT
5 5
1- BLK
6 6
2+ Dark Gray cable
7 7
8 2- 8

10kΩ
1+

1-

2+ 3
2- 4
NCM-227D
Dimmer unit

Connect the dimmer unit to Junction box when you use Junction box.
Connect the dimmer unit by using Junction box when you use an external dimmer
at the Slave display.

《 reference 》 Other dimmer units


NCM-227 (for NWW-5/16) NCM-329 (for NWW-24/25/26)

1+ 1+ 1+
1 analog 1
2 1- 2 1-
1- 1kΩ 2+
3 3
4 AC100V 4 2+
NCM-227 2- 5 2- EL
Dimmer unit
Analog display

NCM-329 50kΩ
Dimmer unit
・Input circuits
GPS input (TB513 -①②) ・・・ For GPS speed display
+ 200Ω
● to internal circuit

IEC61162-1
(NMEA)

Power Fail ACK in (TB518-④⑤)・・・ Power fail alarm release


contact or TTL
+ S511
440Ω
● ● ● Contact input: ③④ON
To internal

or circuit TTL input: ③④OFF

Release: ⑤ON


Only input: ⑤OFF.

System Alarm ACK in (TB519A-④⑤)・・・ System alarm release ← now unused it.
contact or TTL
+ S511
440Ω
● ● ●
To internal
Contact input: ①②ON

or circuit TTL input: ①②OFF

- ●
11/41

・Output circuits
IEC61162-1 output (TB515A -①②③④, ⑤⑥, and ⑦ ⑧) ・・・ Digital interface
(NMEA0183) (TB515B-①②、③④、⑤⑥、⑦⑧)
4 channels of TB515A

+ 4 channels of TB515B,
RS-422 standard output V1.5 or V2.3(default)
- It is possible to set it
individually.

200pulse/nm opto-coupler output (TB519B-①②、③④、⑤⑥、⑦⑧)


200Ω
2 channels of ①② and ③④

2 channels of ⑤⑥ and ⑦⑧
absolutely maximum
30V, 50mA 0-9900pulse/nm (200 standards) can
- be individually set. (100 steps)
‘0’ means output Off

200pulse/nm relay point of contact output (TB519A-⑥⑦)


Maximum rating 0-2000pulse/nm (0 standards) can be set.

30V,1A (100 steps)
NO ‘0’ means output Off

Analog output (TB512 -③④, ⑦⑧) ・・・ For Analog Display


automatic return
0 to +10V is made to correspond to 0 to
0.75A FS kn. FS can be set to 10 to 40kn in
● ○ ○
±10V each 1kn step. The separate setting of 2
50mA max channels is not completed.

Power Fail Alarm relay point of contact output (TB518 -①②③) ・・・ Power fail output
NC
Maximum rating
○ COM


30V,2A
NO

System Alarm relay point of contact output (TB519A -①②③) ・・・ ← now unused
NC
Maximum rating
○ COM


30V,2A
NO
12/41

-3. Signal Processor NJC-25

TB2 8 8 8 8 8 8 8 8
to transducer
Dip switch
S01 S104 S103 S102 S101
12345678 12345678 12345678 12345678 12345678

All usually “00000000"


Power switch
CDC-1228

S200
Signal Processor
to signal distributor TB1
P101
3 TB100 Fuse
2 Tap switch 6.3A AC input
1 2A EL output
Program writing

Fuse
2A
Power
transformer CMN-686
2M TRX unit

・The tap in the power supply part is changed according to the voltage of ship’s main.
Confirm Check box of the back side of the lid.
Ship’s main Tap change of TB11
100V
Low
110V ① ⇔ ②
side
115V
220V High ←Factory
① ⇔ ③
230V side setting
Always turn on S200 usually.
・When the program update is done, P101 is connected with PC. It loads a program from PC.
Turn on ⑦⑧ of S01.
Turn off S01⑦⑧ after ending the update.
S02 is a reset switch.
・When the power is turned on, the lamp test and version information are displayed
in monitor LED.
The first about 5 sec. ………… LED off
About 5 sec. afterwards. …… 【88888888】 ← lamp test
About 20 sec. afterwards. ……【1.00-.1d】 ← program version information *
*:When S101 ① is set to "ON", volume No. is displayed.

・Alphabetic mark of seven segments LED

Character A B C D E F G H I J K L M N O P Q R S

Display

Character T U V W X Y Z 0 1 2 3 4 5 6 7 8 9 - .

Display
13/41

・Confirmation of transmission output

TP404 Frequency Output Voltage


(TX_MONI) 2MHz 150±50Vpp
TP400
(GND)
1000mS
100mS
TP6 (TXG)
TP7 (GND)
2mS

・Confirmation of reception signal


The noise of the reception must be 1.0V or less.
The bottom of the sea signal is observed in the quay.
2ms/div

Bottom:5m

TP452
TP454 2nd. Echo of bottom

noise
0.65V

GND level

TP6

・Transmission B voltage +30V


● ●

ON/OFF CMN-686
AC control Transmitter
● ●
26V DC40V

Protection
circuit

This power circuit is controlled so that the transmission B voltage may become +30V.
After about 25 seconds pass from power ON, the transmission is begun.
When abnormality (over-voltage of the transmission output, over-current of power FET)
in the transmitter is detected, the transmission pulse is stopped in the protection circuit.
14/41

・Dip switch
No Dip switch default Item Function 1:ON, 0:OFF
1 S01 ① 0 ――― (unused)
2 ② 0 ――― (unused)
3 ③ 0 ――― (unused)
4 ④ 0 ――― (unused)
5 ⑤ 0 ――― (unused)
6 ⑥ 0 ――― (unused)
7 ⑦ 0 ――― 00:usually, 11:Program update
8 ⑧ 0 ―――
9 S101 ① 0 VOL No. 0:usually, 1:Software volume No.
10 ② 0 ――― (unused)
11 ③ 0 WT processing 0:usually
12 ④ 0 ――― (unused)
13 ⑤ 0 ――― (unused)
14 ⑥ 0 ――― (unused)
15 ⑦ 0 WT noise 0:Usually(auto), 1:Manual(-000000=0.0V)
16 ⑧ 0 WT noise polarity 0:(reference)+(set value), 1:(reference)-(set value)
17 S102 ① 0 WT noise 000000: Usually
18 ② 0 Set value
19 ③ 0
20 ④ 0
21 ⑤ 0
22 ⑥ 0
23 ⑦ 0 ――― (unused)
24 ⑧ 0 Maintenance 0: Usually
25 S103 ① 0 ――― Internal use (Do not change the setting. )
26 ② 0 ――― Internal use (Do not change the setting. )
27 ③ 0 ――― Internal use (Do not change the setting. )
28 ④ 0 COM1 Monitoring Data Output setting 0:Usually, output:1
29 ⑤ 0 Local correction 0: Usually
30 ⑥ 0 ――― Internal use (Do not change the setting. )
31 ⑦ 0 ――― Internal use (Do not change the setting. )
32 ⑧ 0 ――― Internal use (Do not change the setting. )
33 S104 ① * Monitor display 0000: Internal clock (1/10 sec)
However, 1000:
0100: Quantity of 2MHz data sampling
In case of
1100:
S104 ⑤ -⑧ 0010: Calculation mode
34 ② * =“0000“ 1010: Distance Odo[nm]
effective 0110: Distance Trip[nm]
1110:
0001:
35 * 1001:

0101:
1101:
0011: WT speed [kn]
1011: 3.3V Voltage [V]
36 ④ * 0111:
1111:
37 ⑤ 0 WT processing 00:Usually
38 ⑥ 0
39 ⑦ 0 WT filter 00:Usually
40 ⑧ 0
15/41

-4. Transducer NKF-547, NKF-531E


2MHz elements × 2 pieces (Dual beam)
Thermistor × 1 piece (Speed of the sound correction)

Structure of transducer (bottom view)

Bow

②Thermistor

Bow mark
(White paint)

①beam ③beam

Internal connecting wires CFT-022B/023B


TB2
① ●

Fore ① ● ● Z0 ≈ 50Ω
beam ② ●


Thermistor

Thermistor ● ● 2.5kΩ/25℃

③ ●

After ⑤ ● ● Z0 ≈ 50Ω
beam ⑥ ●

Cable length: 25/30/40m



⑧ Ground it.

・Quality judgment of transducer


3 each shield lines are insulated, it is 1MΩ or more.
The matching coil is built into shield line ① and ③.
The resistance between core and shield line is about 0-3Ω.
The resistance of the thermistor rises if the temperature lowers. (about 5kΩ at 6℃ )
The insulation resistance between shield line and the hull is 1MΩ or more.
(Because the impedance measurement of the element changes by the length of the cable,
it is difficult in the simple measurement method. )

・Kind of transducer
Usage Transducer type Remarks
for NKF-547 CFT-022B-30 30m, for production
CFT-022B-01 40m, for maintenance
for NKF-531E CFT-023B-01 40m, for maintenance
16/41

-5. LED status for maintenance


NQA-4288
Unit Part No Function Status
CQD-1988 CD544 Dsub-9 input (Blink, PC update data input)
CD545 Input from NJC-25 Blink (light: data input)
CD546 NMEA input from GPS Blink (light: data input)
CD547 Input from NWW-65 Blink (light: data input)
CD548 System Alarm Ack input (Light, only external connection)
CD551 Power Fail Alarm Ack input (Light, only external connection)
CD641 JRC maintenance output Blink (light: data output)
CD642 NMEA-A output Blink (light: data output)
CD643 NMEA-B output Blink (light: data output)
CD644 Dsub-9 output Blink (light: data output)
CD645 Output line to NJC-25 Blink (light: data output)
CD647 Output line to NWW-65 Blink (light: data output)
CD651 +12V (for OP-AMP) Lighting always
CD652 +35V (for distance counter) Lighting always
CD653 +5V (for data output driver) Lighting always
CD654 +3.3V (for CPU) Lighting always
CD655 +1.5V (for FPGA) Lighting always
CD656 –12V (for OP-AMP) Lighting always
CD657 Distance counter pulse output Blink (Change according to speed )
CD658 Power Fail Alarm output Light at alarm
CD659 System Alarm output (Now unused)
CD660 Puls3 output Blink(light at relay on) default: no light

NJC-25
Unit Part No Function Status
CDC-1228 CD44 DOWN data input Blink (light: data input)
CD45 UP data output Blink (light: data output)
CD46 Dsub-9 output Blink (light: data output)
CD47 Dsub-9 input (Blink, PC update data input)
CD48 TXG transmitting gate Blink (PRR:1sec. Light:5 times)
CD49 PROTECT Not Lit (light: abnormal TX)
CD150 +3.3V (for CPU) Lighting always
CD151 +15V (for OP-AMP) Lighting always
CD152 –15V (for OP-AMP) Lighting always
CD153 +30V (for transmission) Lighting always
CD154 +2.5V (for FPGA) Lighting always
CD155 +5V (for data output driver) Lighting always
CMN-686 CD401 +15V input Lighting always
CD402 +8V (for analogue) Lighting always
CD403 +5V (for logic) Lighting always
CD404 +30V (for transmission) Lighting always
CD426 Transmission output Blink (PRR:1sec. Light:5 times)
17/41

-6. Internal checkpoint

NQA-4288
Unit Part No Function Status
CQD-1988 TP501 + 12V + 12V±1.5V
TP502 + 35V + 35V±4V
TP503 + 5V + 5V±0.2V
TP504 + 3.3V + 3.3V±0.15V
TP505 + 1.5V + 1.5V±0.1V
TP506 – 12V -12V±1.3V
TP507 ――― (Unused)
TP510 CPU RESET “H" Level
TP511 WDT “H" Level
TP512 (reserve) ―――
TP521 GND GND

NJC-25
Unit Part No Function Status
CDC-1228 TP1 + 3.3V + 3.3V±0.15V
TP2 + 15V + 15V±0.7V
TP3 -15V -15V±0.7V
TP4 + 30V + 30V±6V
TP5 GND GND
TP6 TXG 1s
100ms 2 ms

TP7 GND GND


TP8 + 2.5V + 2.5V±0.1V
TP9 GND GND
TP10 TX2M/10
15Vpp±5Vpp

TP11 GND GND


CMN-686 TP400 GND GND
TP401 + B30V + 30V±6V
TP402 + B_GND GND
TP403 TX_SIG(transmission drive)

TP404 TX_MONI (TX output) Same as TP10, However150±50Vpp


TP405 DETECT (FET current)
TP441 LOC_F1 (Local Frq. F1) 1.55MHz
TP442 LOC_F2 (Local Frq. F2) 380kHz
TP443 LOC_R1 (Local Frq. R1) 1.54MHz
TP444 LOC_R2 (Local Frq. R2) 390kHz
TP450 GND GND
TP451 Fore_Freq(Fore Frequency) About 70kHz
TP452 Fore_Ampl (Fore Frequency) 6-3. Refer to the clause.
TP452

TP6
TP453 Aft_Freq (Aft Frequency) (TP451 is similar)
TP454 Aft_Ampl (Aft Amplitude ) (TP452 is similar)
18/41

7. Speed Test
After installation, the indicated speed must be calibrated in comparison with corresponding true
speed to make the best use of the excellent features of this Doppler Log and effectively utilize it.
For the speed calibration, in usual, the ship is run between Mile Post to obtain a calibrated value
from the turnaround time. Measured values in this time must be accurately recorded on a
Doppler Log speed test sheet and it must be stored. If the equipment faults some other day and
the circuit board are replaced, this record will serve for accurate adjustment.

Before running between the Mile Post, the ship must be provisionally run enough to reduce the
speed variation during passing between the posts, as possible. In addition the ship must be also
sailed correctly in directions indicated by the Mile Post. When the effects of both ocean current
and wind can be regarded to be constant in time during test, the ship may go and return once for
measurement. When these effects are, however, considered to very in time, it preferably goes and
returns two times. If the difference between measured values in the same direction exceeds 0.5
knot, the measurement must be repeated.

-1. For the Mile Post running test, the ship usually goes and returns four times at 1/4, 2/4, 3/4
and 4/4 of the main engine’s rating.
-2, The rotation frequency of the propellers and course should be made constant at a point,
at least, one nautical mile away from the first Mile Post, before entering the test area,
and kept constant until the test ends.
-3. The instant ship passes by Point A of Figure below, depress both a stopwatch 1 and
reset button of the Main Display of this equipment.
-4. The instant the distance counter indicates a reading of 0.01nm, depress another stopwatch 2.
-5. The instant the ship passes by point B, again depress the stopwatch 1 to find a time t1
required for running between the two points, the Mile Post.
-6. The instant the distance counter indicates a value of 1.01nm, depress the stopwatch 2 to
obtain a time t2 required for running 1.00nm of the Doppler Log.
Note: Steps -5 and -6 may be reversed in time.
-7. Calculate the true and log speeds from above measured times.

True speed = a 3600 [ kn ] a: Distance between the Mile Post [nm]


t1
t1: Required time between the Mile Post [sec]
3600
Log speed = 1 [ kn ]
t2 t2: Required time for running 1.00nm of LOG [sec]
-8. Run the ship over a different zone of the test area of sea in every measurement.
When entering a return zone after passing a go-zone, the ship should go a long way round so
as to keep the speed and course constant. Measure in the same manner as on the go-zone.
Post Post

a
A point B point

B point A point

Mile Post Running Test


-9. Calculate each mean value of a true speed and the log speed of the turnaround.
And, calculate the calibration value (=Adjust) by the following expression.
Average true speed Average Log speed
Calibration value = 100 [%]
Average true speed
The Mile Post running test does four round trip usually. However, because the Doppler Log
is excellent to the straight line of the speed, proofreads the speed by the first one round trip.
And, it confirms it in three round trips of the remainder.
19/41

MEASUREMENT DATA OF SPEED LOG

Ship’s Name: Date: Ship’s Officer:

SPEED LOG Model: JLN-205 Serial No. Engineer in charge:

Speed calibration Location: Sea condition: Draft Fore:


Correction value after calibration: % Mid:
Aft:
Run Load of RPM of Distance Time Speed Average Speed Error Ship’s Wind Remarks
No. Main Pro- True Log True Log True Log True Log Course (Correction
Engine peller nm nm sec sec kn kn kn kn kn % True Value)
20/41

8. System Block diagram

NWW-65S NWW-65 NWW-5/7/16 NWW-24/25/26


Slave display Main Display Remote Display Analog Display
(Option) (option) (option)

NQA-4288
NCM-227D 250V-TTYCS-4 (YARD Max. 100m) 250V-TTYCS-4
Dimmer Unit
CFQ-7222
CFQ-7221

Signal Distributor
(option) 250V-TTYCS-4 (YARD Max. 100m) NCM-329
Dimmer Unit
(option)
Max. 15m)
CFQ-7221 (JRC 5m)
TTYCS-4

250V-TTYCS-1 (YARD Max. 100m)


CFQ-7222 (JRC 5m) NMEA-1
(YARD

250V-TTYCS-1 (YARD Max. 100m)


NQD-2025 NMEA-2
250V-TTYCS-1 (YARD Max. 100m)
Junction Box NMEA-3
250V-TTYCS-7 (YARD Max. 100m) 250V-TTYCS-1 (YARD Max. 100m)
(option) NMEA-4
250V-TTYCS-1 (YARD Max. 100m)
NMEA-5
250V-TTYCS-1 (YARD Max. 100m)
NMEA-6
NJC-25 250V-TTYCS-1 (YARD Max. 100m)
NMEA-7
250V-TTYCS-1 (YARD Max. 100m)
Signal 250V-TTYC-4S (YARD Max. 500m) NMEA-8
Processor
250V-TTYCS-1 (YARD Max. 100m)
LOG-1
250V-TTYCS-1 (YARD Max. 100m)
LOG-2
250V-TTYCS-1 (YARD Max. 100m)
LOG-3
250V-TTYCS-1 (YARD Max. 100m)
LOG-4
Transducer Cable

Transducer Cable (JRC Max. 25m)


(JRC Max. 30m)

250V-TTYCS-1 (YARD Max. 100m)


Power fail alarm output

0.6/1kV DPYC-1.5 (YARD) Ship’s Main 100・110.115/220/230VAC 60Hz 1φ


250V-DPYC-1.25 (YARD) DC24V input ( for Power fail alarm )
NKF-547 NKF-531E
250V-TTYCS-1 (YARD) GPS IEC61162-1 Input ( for GPS speed display )
Transducer Transducer
(option)
JLN-205 Doppler Log (SDME) OVERALL SYSTEM BLOCK DIAGRAM
21/41

9. Connection diagram (Standard composition)


22/41

Connection diagram (Option composition)


23/41

10. Circuit diagram


-1. Main Display NWW-65

DPU UNIT
POWER CONTROL
24/41

-2. Signal Distributor NQA-4288

TERMINAL BOARD
25/41

-3. Signal Processor NJC-25

2M_TRX UNIT

SIGNAL PROCESSOR
26/41

11. PCB Unit View


-1. Main Display / CMJ-418L DPU

G
27/41

-2. Main Display / CBL-109 POWER CONTROL


28/41

-3. Signal Distributor / CQD-1988 TERMINAL BOARD


29/41

-4. Signal Processor / CDC-1228 SIGNAL PROCESSOR


30/41

-5. Signal Processor / CMN-686 2M_TRX UNIT


31/41

12. Outline &. Setting drawing


-1. Main Display NWW-65A (Desk top type)
32/41

-2. Main Display NWW-65B (Flush mount type)


33/41

-3. Signal Distributor NQA-4288


34/41

-4. Signal Processor NJC-25


35/41

-5. Transducer NKF-547


36/41

-6. Transducer NKF-531E (Option)


Use this gland when you
connect the dimmer unit.
Do a blind lid when not
using it.
-7. Junction Box
NQD-2025 (Option)

Connect CFQ-7221 and CFQ-7222


of NWW-65. Connect it to NQA-4288.
1 hole of 3 holes is the remainder.
37/41
38/41

-8. Remote Display NWW-5 (option)


39/41

-9. Remote Display NWW-16 (Option)


40/41

-10. Distance Counter NWW-7 (Option)


41/41

13. Spare Parts List

SET PER
SHIP No. SPARE PARTS LIST FOR USE
VESSEL
MODEL JLN-205

Doppler Log
QUANTITY REMARKS
ITEM NEME OF PART OUTLINE WORKING SUB
No. (Dimension in m/m) DESCRIPTION
SPARE MARK OF
PER PER JRC CORD No. BOX No.
SET VESS

20

φ5.2
MF51NR0.5
1 1 2
Fuse 5ZFAA00147

20 φ5.2
250V A TSC2A
2 3 2
Fuse 5ZFCA00118

20
φ5.2

215 3.15
3 1 2
Fuse 5ZFAP00101

20
φ5.2

ULT SC 6.3AN1
4 1 2
Fuse 5ZFCA00034

MFR’S NAME JAPAN RADIO CO.,LTD. DRW. No. 7ZXBS0020


For further information contact:

Since 1915

HEAD OFFICE & Nittochi Nishi-Shinjuku bidg.


SALES DEPT. 10-1, Nishi-Shinjuku 6-chome, Shinjuku-ku,
Tokyo.160-8328 JAPAN
Phone : +81-3-3348-0151
Fax : +81-3-3348-3648

MAIN PLANT 1-1, Shimorenjaku 5-chome, Mitaka-shi,


Tokyo.181-8510 JAPAN
Phone : +81-422-45-9111
Fax : +81-422-45-9110

EDITION 3