Pump Sizing Calculation
M
SA
Calculation Objective
Calculation Basis
E T
E
Calculation Methodology
SH
L E
P
Assumptions
M
Software used
SA
Conclusions
References
Attachments
Pump Sizing Calculation
DOC. NO. CEPL-PC-001-CA-015 REV. 0
PROJECT NO. PO. 4500098732 / 10 / 01.01.2018 PAGE NO. 3 of 3
PROJECT TITLE Supply of PF Process Calculation Spreadsheet (Excel Forma)
This spreadsheet provides the pump sizing calculations (Hydraulic power, Shaft power and NPSHA)
Input Results
Hydraulic Power:
The ideal hydraulic power to drive a pump depends on;
* Mass flow rate
* Liquid density
* Differential head
Ph (kW) = q ρ g h / (3.6 *10^6)
E T
E
3
1000 ρ Density of fluid (kg/m )
H
2
9.81 g Gravity (9.81 m/s )
Suction head
0 PA Suction vessel pressure (m)
E S Discharge head
0 PB Discharge vessel pressure (m)
2
7 HA Static head (m) L
ΔPA Frictional pressure drop (m)
P
35 ΔPB Frictional pressure drop (m)
30 HB Static head (m)
M
5 PS Total suction head (m) 65 PD Total discharge head (m)
SA
60 h Differential head (m)
3.3 Ph(kW) Hydraulic power (kW)
Shaft Power:
The shaft power is the power transferred from the motor to the shaft of the pump.
P s(kW) = P h(kW) / η
NPSHA :
The NPSHA (Net Positive Suction Head, Available) depends on;
* Pressure at pump suction (m)
* Ambient Pressure (m)
* Vapor Pressure (m)
NPSHA = 14.8 m