Technical Data:
Air drive pressure pL: 1-10 bar / 14,5 - 145psi
Pressure ratio i: 1:30
Compression ratio 1:20
Minimum suction pressure pA: 15
Maximum suction pressure pA: 300 bar
Maximum outlet pressure pB: 300 bar
Displacement volume/double stroke: 60 cm³
Maximum cycles: 130 / min

Release 03 / 2012 • MAXIMATOR • Technical Data Sheet DLE 30-1 • Page 1 of 3 • DB.01.02.02.17
Stall pressure: PB = i * pL
Standard Connections:

DLE 30-1 Air drive: 3/4 BSP


single acting, single air drive head DLE 30-1 (-GG) Inlet/Outlet: 1/4BSP
single stage
Maximum operating tempreature 100°C
Net weight: 13 kg
Pressure and flow performances, please see enclosed graph.

Materials of construction hp section DLE 30-1: Standard seal package: PTFE, Viton
Compressor head: 1.4305
HP cylinder: 1.4542
HP piston: 1.4305
Fittings: 1.4305
Balls: 1.4034
Springs: 1.4310
Approximate Dimensions: Length: 448 mm
Width: 181 mm
Height: 275 mm
Available Options: Inert gas service (standard) DLE 30-1 (-GG)
Oxygen service: DLE 30-1-GG-S
CO2 service: DLE 30-1-GG-C
In-/Outlet: 9/16-18UNF DLE 30-1-UU
In-/Outlet: 1/4NPT DLE 30-1-NN
Available Accessories:

Air control units with filter pressure regulator, control pressure gauge and shut off valve: DLE 30-1 with C2
To protect the booster against excessive outlet pressures or to limit the outlet pressure, a safety DLE 30-1 with C2/SVair
valve can be fitted to the air control unit in the air drive line: (The required outlet pressure
has to be indicated.)
Please consult factory for more information. All technical and dimensional information subject to change. All General Terms and Conditions of sale, including
limitations of our liability, apply to all products and services sold.

MAXIMATOR GmbH, Lange Strasse 6, 99734 Nordhausen, Telephone +49 3631 9533 – 0, Telefax +49 3631 9533 – 5010, www.maximator.de, info@maximator.de
M a x i m u m P r e s s u r e.
High Pressure Technology • Testing Equipment
Hydraulics • Pneumatics

Release 03 / 2012 • MAXIMATOR • Technical Data Sheet DLE 30-1 • Page 2 of 3 • DB.01.02.02.17

MAXIMATOR GmbH, Lange Strasse 6, 99734 Nordhausen, Telephone +49 3631 9533 – 0, Telefax +49 3631 9533 – 5010, www.maximator.de, info@maximator.de
M a x i m u m P r e s s u r e.
High Pressure Technology • Testing Equipment
Hydraulics • Pneumatics

Performance Graph DLE 30 - 1


Drive Pressure 4 bar Max. Outlet Pressure 300 bar

140 1400

Pv = 30 bar
120 1200

Air Consumption
100 Pv = 25 bar 1000
Outlet Flow
(lN/min)

(lN/min)
80 Pv = 20 bar 800

Pv = 15 bar
60 600

40 400

20 200

Release 03 / 2012 • MAXIMATOR • Technical Data Sheet DLE 30-1 • Page 3 of 3 • DB.01.02.02.17
0 0

0
20

40

60

80
0

10

12
Outlet Pressure (bar)
Outlet Flow at Pv = 15 bar Outlet Flow at Pv = 20 bar Outlet Flow at Pv = 25 bar
Outlet Flow at Pv = 30 bar Air Consumption

Performance Graph DLE 30 - 1


Drive Pressure 6 bar Max. Outlet Pressure 300 bar

200 2500
Pv = 45 bar
180

160 2000

Air Consumption
Pv = 35 bar
140
Outlet Flow

120 1500

(lN/min)
(lN/min)

Pv = 25 bar
100

80 1000
Pv = 15 bar
60

40 500

20

0 0
0

0
30

60

90
0

12

15

18

Outlet Pressure (bar)


Outlet Flow at Pv = 15 bar Outlet Flow at Pv = 25 bar Outlet Flow at Pv = 35 bar

Outlet Flow at Pv = 45 bar Air Consumption

Performance Graph DLE 30 - 1


Drive Pressure 8 bar Max. Outlet Pressure 300 bar

250 3000

Pv = 55 bar
2500
200
Pv = 45 bar
Air Consumption

2000
Outlet Flow

150 Pv = 35 bar
(lN/min)

(lN/min)

1500

100 Pv = 20 bar
1000

50
500

0 0
0

0
40

80
0

12

16

20

24

Outlet Pressure (bar)


Outlet Flow at Pv = 20 bar Outlet Flow at Pv = 35 bar Outlet Flow at Pv = 45 bar

Outlet Flow at Pv = 55 bar Air Consumption

MAXIMATOR GmbH, Lange Strasse 6, 99734 Nordhausen, Telephone +49 3631 9533 – 0, Telefax +49 3631 9533 – 5010, www.maximator.de, info@maximator.de

Potrebbero piacerti anche